PLEASE COMPLETE AND RETURN AS SOON AS POSSIBLE
|
|
- Hope Nichols
- 5 years ago
- Views:
Transcription
1 ED4_PG1_STD Version 3 Manor Farm Industrial Estate, Flint, Flintshire CH6 5UY Telephone +44 (0) Facsimile +44 (0) PLEASE COMPLETE AND RETURN AS SOON AS POSSIBLE TVC Quote No. Company Name Address Customer The above references will be added to all documentation including drawings Delivery Address (if different from above) Note: this document will be the official document used to configure your controller. Complete it carefully as any changes may result in additional cost and delayed delivery. Any features requested in this document that are not already included in the quotation may be subject to a price increase. REQUIREMENTS Please complete the attached questionnaire and supply all relevant information in order that the lift control panel(s) may be designed and manufactured. Inaccurate or incomplete information may delay delivery. For Modernisation jobs, all application data on existing equipment and any requirements not covered on the quotation should be recorded and attached to this form. Please contact TVC if any questions arise regarding the required data. Authorised By Print Name Date TVC cannot accept this document unless signed and dated Internal use only. TVC contract number: 15/09/11 1
2 ED4_PG2_VEC/VF Version 10 MAINS SUPPLY VOLTS IS SUITABLE NEUTRAL AVAILABLE? Yes No PHASE 4 WIRE 3 WIRE HZ PLEASE SUPPLY MOTOR DATA SHEET FOR APPLICATION OR COMPLETE DETAILS BELOW DATA SHEET ATTACHED Y N If yes, Motor data sheet ref number Proceed to NEXT SHEET MOTOR APPLICATION DETAILS / TYPE CAR SPEED m/s V PAY LOAD Kg Hz ROPING 1:1 2:1 RPM SHEAVE DIAMETER mm KW GEAR TYPE AMPS GEAR RATIO FLYWHEEL / HEAVY BRAKE COUPLING Y N TRAVEL m We will assume the answer is no, however, if yes, please supply full details including size & material type BRAKE DETAILS VOLTS DC AMPS TVC preferred standard is 100VDC, 2A max. ADVANCE BRAKE LIFT Y N Allows brake lift before doors are closed for faster floor exit. Mono-stable door switch on door operator required. METHOD OF BRAKE RELEASE MECHANICAL ELECTRICAL DURING HANDWIND PROCEDURE PULSE GENERATOR DETAILS* (Closed Loop only) 1024 PPR 10-30VDC PUSH-PULL COMPLEMENTARY 1024PPR 10-30VDC DIFFERENTIAL RS422 LINE DRIVER 2048PPR 10-30VDC ENDAT ABSOLUTE (MULTI TURN) PROVIDE DETAILS Voltage Pulses per Rev Output Configuration MOTOR FAN VOLTS AMPS PHASES PLEASE NOTE ALL NEW SASSI MOTORS REQUIRE A 230V 1 PHASE 0.14A MOTOR FAN INTERFACE The following assumptions will be made unless specified otherwise using the space below: - Lift counterweighted at 50%. Gear efficiency approximately 70%. Well efficiency approximately 80%. No compensation ropes fitted. For contract speeds up to and including 1.75m/s reduced buffer stroke not applicable. Maximum acceleration & jerk rates Please specify if alternate values are required Lift speed (m/s) Accel rate (m/s²) Jerk rate (m/s³) < < < /03/12 2
3 ED4_PG3_STD Version 14 FAST TRACK (Standard) Options No. OF FLOORS No. OF CAR ENTRANCES 1 2 IF 2 PLEASE INSERT FLOOR MARKINGS FRONT NON FAST TRACK (Non Standard) OPTIONS NON-SELECTIVE DOOR OPENING SELECTIVE DOOR OPENING PLEASE COMPLETE REAR FLOOR ENTRANCES REAR FLOOR HEIGHT (M) 3M floor heights will be assumed if not specified. MAIN (HOMING) FLOOR FIRE FLOOR CONTROL SYSTEM SIMPLEX DUPLEX TRIDENT GROUP If duplex/trident/group serving odd floors, please supply details FULL COLLECTIVE DOWN COLLECTIVE APB CONTROL NON -SEL COLLECTIVE OPTIONAL FEATURES ECO-MODE Y N REFER TO WEBSITE FOR DETAILS PANEL TEST LOW SPEED Y N PLEASE LIST ANY SPECIAL OVER TRAVEL OVERRIDE Y N REQUIREMENTS ADVANCE DOOR OPENING Y N DOOR DETECTOR SUPPLY 110VAC PREFERRED 230VAC 12VDC ALARM SUPPLY Y N 12VDC EMERGENCY LIGHT SUPPLY Y N ALARM CONTROL RELAY X 2 CHANGEOVER CONTACTS Y N REMOTE GOVERNOR TRIP Y N V A REMOTE GOVERNOR RESET Y N V A HANDWIND FLOOR LEVEL BUZZER (not required with HW43) Y N DIGITAL HANDWIND UNIT Y N PANEL MOUNTED THERMOSTAT (5-40ºC) Y N EMERGENCY GENERATOR SUPPLY Y N If yes, complete ESUP questionnaire FIRE CONTROL Only available with fully automatic Y N door control SPECIFICATION Y N STANDARD FEATURES Service control / Car preference Motor room thermostat interface Fire Evacuation EN81-72 Firefighting 90% load weighing 110% load weighing Emergency / fire alarm recall to fire floor, doors dwell closed. EN81-73 Fire Alarm IF YES SPEC REF PAGES TVC CARTOP CONTROL UNIT (CTC1B000) Y N BATTERY BACKUP LIGHT INCLUDED TVC PRE-WIRED - LIMIT SWITCH TREE & RAMP Y N TVC emfone AUTODIALLER Y N CAR ONLY FULL SYSTEM OVERSPEED GOVERNOR SUPPLIED BY TVC Y N UNI-DIRECTIONAL BI-DIRECTIONAL Note: 300mm pulley diameter gear ratio 4:1. Governors with encoders are bi-directional only. TVC ELEVATOR MONITORING (EMU) SYSTEM Y N IF YES NEW EXISTING PROTECTION AGAINST UNINTENDED CAR MOVEMENT Y N IF YES, PLEASE AS EN81-1:1998+A3:2009 / EN81-2:1998+A3:2010 PROVIDE DETAILS 3 06/10/14
4 ED4_PG4_STD Version 6 FAST TRACK (Standard) Options SECTION 1 - POSITION INDICATORS NON FAST TRACK (Non Standard) OPTIONS DIGITAL INDICATORS 24VDC Select type DIGITAL INDICATORS DEWHURST SPECIFY eg ULS32/LD90 STENTORGATE VOLTAGE ILE 4 WIRE SERIAL A&A OMEGA 4 SUPPLY CONNECTION DIAGRAM FOR INTERFACING DRUCEGROVE FITTED AT: CAR MAIN FLOOR ALL FLOORS (If free issue, please ensure we receive the unit at least two weeks ENCODER BOARD REQUIRED Y N before dispatch date, if not we reserve the right to dispatch the contract minus the free issue equipment) HALL LANTERN ARROWS Y N V (DIRECTION OF DEPARTURE) ARE THESE DRIVEN BY THE DIGITAL INDICATORS Y N STANDARD INDICATOR SIGNALS PROVIDED FLOOR POSITION, LIFT DIRECTION, LIFT ON FIRE CONTROL, LIFT OVERLOADED, LIFT OUT OF SERVICE PLEASE PROVIDE LIST OF INDICATOR MESSAGES SECTION 2A - SPEECH UNIT SPEECH UNIT DEWHURST STENTORGATE ILE DRUCEGROVE DIGITALKER Select type SECTION 2B - STANDARD SPEECH SIGNALS PROVIDED LIFT POSITION DOORS OPENING, DOORS CLOSING LIFT GOING UP, LIFT GOING DOWN LIFT ON FIRE CONTROL ALARM LIFT OVERLOADED LIFT OUT OF SERVICE SUPPLY CONNECTION DIAGRAM FOR INTERFACING SPECIAL SPEECH SIGNALS REQUIRED SPECIAL SPEECH PHRASES MAY INCUR AN ADDITIONAL COST SECTION 3 CALL ACCEPTANCE INDICATORS DEWHURST DUAL ILLUMINATION ENBUZZ CAR CALL ACCEPTANCE 24 VDC 20mA LANDING CALL ACCEPTANCE 24 VDC 20mA 06/03/12 4
5 ED4_PG5_STD Version 10 FAST TRACK (Standard) OPTIONS SECTION 5 DOOR OPERATOR DETAILS NON FAST TRACK (Non Standard) OPTIONS DOOR OPERATOR DETAILS FULLY AUTOMATIC CAR & LANDING Y N POWER CAR & MANUAL LANDING Y N IF YES PROCEED TO SECTION 5B TYPE MANUAL CAR & LANDING Y N IF YES PROCEED TO SECTION 5A RETIRING RAMP Y N QTY RAMP VOLTS RAMP CURRENT SECTION 5A RAMP DETAILS QTY RAMP DETAILS (100W MAX TOTAL) Select type 100VDC (TVC PREFERRED) RAMP VOLTS 110VDC RAMP CURRENT 180/185VDC 200VDC SECTION 5B Select type IS DOOR OPERATOR NEW EXISTING SEMATIC SDS VVVF* Select type SELCOM AC / SEMATIC AC DC68* SELCOM VVVF PEGASUS * EXPRESS AC SELCOM VVVF ECO * EXPRESS E TYPE* SELCOM VVVF MIDI/SUPRA * GALMOD** SIEMANS AT18* GALMOD HA** (With fault monitoring) SIEMANS AT25* GALVVVF* SEMATIC F28/F29* GALVVVF HA* (With fault monitoring) SELCOM DC* GALMOH** *Door Nudging Only Available GALMOM** **Door Nudging And Zone Locking Available ECI** FERMATOR VVVF* DOOR NUDGING Y N PROPBROOK** ELECTRICAL ZONE LOCKING Y N 3 PHASE AC (400V) TYPE TYPICAL CABINET DIMENSIONS (mm) VEC/VVVF Height (mm) Width (mm) Depth(mm) 1200 to (1000 incl resistors) 400 Wall or floor mounted DCSCR Height (mm) Width (mm) Depth (mm) Refer to factory. Refer to factory. Refer to factory. HYDRAULIC Height (mm) Width (mm) Depth (mm) 1000 to (1000 incl resistors) 300 or 400 Wall or floor mounted CONTROLLER MECHANICS Front access only. Resistor housing on top or left hand side (if fitted). Please indicate any special requirements regarding size, handing of resistors etc. Typical Cabinet is IP22 rated IS CABINET PLINTH REQUIRED Y N IF YES, PLEASE STATE HEIGHT REQUIRED mm WALL OR FLOOR MOUNTED? WALL FLOOR 13/06/13 5
6 ED4_PG6_SHAFT Version 9 SHAFT SIGNALLING PROXIMITY SWITCHES SUPPLIED BY S TAPEHEAD SUPPLIED BY TVC Only to be completed if tapehead is supplied by others STEEL TAPE LENGTH M SUPPLY VOLTS 110VAC PREFERRED 230VAC BATTERY BACKED UP Y N VPD up to & including 1.75m/s To suit VEC/VVVF/DCSCR RELEVELLING IS NOT AVAILABLE Motor pulse encoder must have a Differential RS422 output or Push pull complementary output Control Panel Motor Encoder GPD up to 1.75m/s (Absolute encoder) To suit VEC/VVVF/DCSCR/HYDVVVF/HYD Overspeed Governor c / w Absolute encoder 20m loom ** Control panel A motor encoder may also be required to feed the drive for closed loop control Is relevelling required Y N ** If Governor is supplied by TVC it comes complete with a connection loom, please specify length required. M If length is not specified,a 20M loom will be supplied VCOM up to 6m/s GPD (Absolute encoder) TO SUIT VEC/VVVF/DCSCR 20m loom ** Is relevelling required Y N Overspeed Governor Control panel Motor Encoder c / w Absolute encoder ** If Governor is supplied by TVC it comes complete with a connection loom, please specify length required. M If length is not specified,a 20M loom will be supplied VCOM up to 6m/s BPD TO SUIT VEC/VVVF/DCSCR TOOTHED BELT SYSTEM SHAFT HEIGHT Control panel Motor Encoder M Is relevelling required Y N 22/11/13 6
7 M R L QUESTIONNAIRE Version 6 Please delete as applicable. WHERE IS CONTROL CABINET TO BE FITTED? LANDING ARCHITRAVE Please provide details H = 2200mm W = 500mm D = 200mm Hinged LHS TVC STANDARD LANDING ARCHITRAVE CONTROL CABINET 304 BRUSHED Stainless Steel 240 GRIT MOTOR INVERTER & DYNAMIC BRAKING RESISTORS TO BE MOUNTED SEPARATE TO CONTROL CABINET, IN CLOSE PROXIMITY TO LIFT MOTOR WHERE IS LIFT MOTOR TO BE FITTED? TOP OF LIFT SHAFT BOTTOM OF LIFT SHAFT Please provide details APPROXIMATE DISTANCE BETWEEN LIFT MOTOR/INVERTER & CONTROL CABINET M LIFT MOTOR TYPE GEARED GEARLESS MOTOR INVERTER SUPPLIED BY TVC TYPE IMPORTANT NOTE: IF ZEIHL ABBEG ZETADYN 2SY INVERTER IS USED, ENSURE K1/K2 CONTACTORS ARE ORDERED WITH 110VAC COILS PLEASE INDICATE SPECIAL REQUIREMENTS REGARDING SIZE, DOOR HINGE, RESISTORS FOR DRIVE CABINET DRIVE CABINET DIMENSIONS (TO BE MOUNTED IN LIFT SHAFT) MOTOR CURRENT =<29A TAPEHEAD 600mmW x 800mmH x 400mmD Resistors will be mounted on top, the height with resistors is 950mm MOTOR CURRENT =<29A VCOM 600mmW x 1000mmH x 400mmD Resistors will be mounted on top, the height with resistors is 1050mmH FOR APPLICATIONS WITH A MOTOR CURRENT GREATER THAN 29A PLEASE REFER TO FACTORY FOR DRIVE CABINET DIMENSIONS METHOD OF HANDWINDING HANDWIND WHEEL FREE WHEEL (GEARLESS) PONY MOTOR PONY MOTOR DETAILS METHOD OF BRAKE RELEASE DURING HANDWIND PROCEDURE MECHANICAL ELECTRICAL CONTROL PANEL OPTIONS Please tick if required CONSUMER UNIT BT SOCKET 3-PIN SOCKET MAINS ISOLATOR SHAFT LIGHT SWITCH CABINET LIGHT 7 13/09/11
Tricon by MCE Data Form Motion Control Engineering Phone (916) Fax: (916)
Data Form Motion Control Engineering Phone (916) 463-9200 Fax: (916) 463-9201 Car controller specification Foreword Document revision date: 3/15/05 Please fill all ten pages completely. It is very important
More informationEnquiry Sheet for LiSA-Lift Controller to EN81. Tel: Fax:
Enquiry Sheet for LiSA-Lift Controller to EN81 Company: ORDER-Nr.: Contact: Date: Tel: Fax: e-mail: Works No.: SITE Ref: Offer required by : ORDER Ref:: Additional standards: EN81-70 Passenger access,
More informationTricon by MCE. Car controller specification. Controller Data Form Motion Control Engineering JER Phone Fax
Motion Control Engineering JER119 0810 Phone 916.463.9200 Fax 916.463.9201 Car controller specification Foreword Document revision date: 06/01/10 Please fill all ten pages completely. It is very important
More informationTECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +
TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + 8 CABIN DOORS DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any
More informationStandard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.
General In This Section PTC PTC-SCR PTC-AC PTC-MG VVMC-1000 SCR VFMC-1000 AC VVMC-1000 MG Traction Controllers, PTC, VVMC, VFMC General Systems described in this section can be used for geared traction
More informationGLOBAL LIFT EQUIPMENT LTD. Fermator Door Spares
Fermator Door Spares Units H42/43 Ashmount Enterprise Park, Flint, Flintshire, CH6 5YL. Tel: 01352 735400 Fax: 01352 735733 Email: sales@global-lift.com www.global-lift.com Tel: 01352 735400 Fax: 01352
More informationMaxPak Plus Analog DC V S Drive
Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings
More information1. MACHINE DATA/ PUMP UNIT 2.TYPE OF CONTROLLER
Toma de datos pagina 1 QUOTE ORDER NEW MODERNISATION. CLIENT REF. DATE DELIVERY 1. MACHINE DATA/ PUMP UNIT MACHINE: Indicate existing motor data. O. GOVERR RULE A3 MOTOR VOLTAGE:...V. MOTOR POWER:... HP.
More informationCENTROIDTM. AC Brushless Drive. Product Spec Sheet
4 Axis, up to 2 KW motors Brake Output for each axis Overtemp and Overcurrent Protection All-software Configuration Self-cooled Fiber Optic Control CENTROIDTM AC Brushless Drive Product Spec Sheet AC Brushless
More informationGoods Lifts kg Capacity SL
Goods Lifts 300-2000kg Capacity SL-2017-02 BKG Goods Lifts Manufactured in Paderborn in the centre of the German industrial heartland, BKG Goods Lifts really are the high quality, well engineered product
More informationSMS PRODUCT CATALOGUE
SMS PRODUCT CATALOGUE CONTENTS 1 TAKEDO 3VF-NXP - LIFT INVERTER Page 3 2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER Page 6 3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT Page 7 4 HYDROVERT VVVF FOR
More informationCenter Winder Specification
Center Winder Specification Bump Roll Edge Guide Photo Eye 2000 Ft/ Min Dancer Arm Center Winder Overview Winding is simply a rotational means to take up and package material for more efficient handling
More informationFiltered PWM Speed Control for Permanent Magnet DC Motors
Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1
More informationDRIVE STARTUP MANUAL. Magnetek HPV900-S2 Drive. PM Motor Installation
DRIVE STARTUP MANUAL Magnetek HPV900-S2 Drive PM Motor Installation CONTROLLER GROUNDING REQUIREMENTS NOTE For the controller to function properly it is very important to provide proper building ground
More informationMicrolift: complete view. STANDARD SHAFT HEIGHT (in mm) GENERAL TECHNICAL SPECIFICATIONS GEAR MACHINE AND CONTROLLER MACHINE ROOM CAR REMOVABLE SHELF
LiftCat 710 Index Shaft dimensions, car and landing doors......................... 1 Standard shaft height........................................ 2 General technical specifications...............................
More informationFincor Series 2230 MKII/2240
Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new
More informationSP5 INSTALLATION AND SETUP MANUAL
SP5 INSTALLATION AND SETUP MANUAL 1 Installation 1.1 Introduction The SP5 System consists of a Data Acquisition unit (DAQ) with two complete Roller control channels, each Roller Control Channel consists
More informationELEVATOR S GENERAL FUNCTIONS GUIDE
ELEVATOR S GENERAL FUNCTIONS GUIDE Traction Sheave Lift Machine Controller Suspension Rope Car Guide Shoe Car Guide Rail Travelling Cable Door Operator Car Car Door Apron Landing Door Position Indicator
More informationModel ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1
Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback
More informationIRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION
IRT quality IN MOTION www.irtsa.com 4000 AT-S/M/L Technical Manual IRT quality IN MOTION E2 0 8 4 1 5 September 2013-Rev. 5 UL Requirements Drives Series 2000 / 4000 AT 1. Field wiring terminal to use
More informationOver 50 years refining the product means that a BKG Goods Lift will be easy to use whilst providing optimum performance and long term reliability.
BKG Goods Lifts Manufactured in Paderborn in the centre of the German industrial heartland, BKG Goods Lifts really are the high quality, well engineered product that you would expect from a German based
More informationExplanation 1 Input External Switch 2 Input Hipot Safety Switch
on the 1100H+ The 1100H+ has capability, which allows you to set up the tester to control external devices with tester functions. You can also use an input on the tester to start a test. For example, the
More informationSuper Calendar. Heated rolls
Application Assistant Surface Winders are used to roll up material such as wire, paper, film, metals and textiles. The surface winding method applies the driving power to a fixed diameter roll or rolls,
More informationADJUSTABLE FREQUENCY CRANE CONTROLS
IMPULSE G+ MINI ADJUSTABLE FREQUENCY CRANE CONTROLS The IMPULSEG+ Mini from Magnetek continues our history of providing the most reliable and cost-effective adjustable frequency crane controls available.
More information231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains
I CAR GATES I CAR ENCLOSURES GUIDE FREIGHT DOORS INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains 202 Standard Operation 202 Slave Mode 201 Sequence of Operations VSD VERTICALLY SLIDING
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationSolar Inverter Manual
Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage
More informationLIFT INVERTER SERIES L1000A
LIFT INVERTER SERIES L1000A EN DE For Modernization and New Installation YASKAWA L1000A FOR HIGH PERFORMANCE LIFT APPLICATION Contents Page 2 Experience & Innovation Page 3 Main Features Page 4 Energy
More informationReSolve Traction Effective Model Solutions SSB...First Choice!
ReSolve Traction Effective Model Solutions SSB...First Choice! * This option is currently available as C-Process. Due for A-Process release later in 2004. The heart of your building KNE's ReSolve Modular
More informationWORLD electronics GFC-IIA. Manual Kutztown Road Reading, PA
WORLD electronics GFC-IIA Manual 7000.9012 3000 Kutztown Road Reading, PA 19605 800-523-0427 TABLE OF CONTENTS Description Page 1 Theory of Operation Page 4 Installation and Initial Adjustment Page 9 Fine
More informationMaster DIALOG INDUSTRY RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications
More informationModel 340i / 680i / 1220i DC drive product manual HG iss 8 1
Model 340i / 680i / 1220i DC drive product manual HG102938 iss 8 1 Sprint Electric Limited, Arundel, UK Tel. +44 (0)1903 730000 Fax. +44 (0)1903 730893 Email. info@sprint-electric.com www.sprint-electric.com
More informationHome Elevator. Planning Guide
Home Elevator Planning Guide Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction. 2 Table of Contents Elvoron Home Elevator...4
More informationSDC,Inc. SCR-Regenerative Ac Drive
SDC,Inc WWW.STEVENSDRIVES.COM APPLICATION NOTE #: AN_REG_GEN000 EFFECTIVE DATE: 12 MAR 02 SUPERSEDES DATE: Original NO. OF PAGES: 10 SCR-Regenerative Ac Drive Using a regeneration controller with adjustable-frequency
More informationElvoron Home Elevator
Creating An Accessible World Elvoron Home Elevator Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site
More informationUSER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT
Quadri di Manovra per Ascensori Lifts Control Panels PELAZZA PEPPINO S.r.l. 20063 CERNUSCO SUL NAVIGLIO (MI) ITALY Via Ponchielli, 6/8 Tel. 02/92.31.694 Fax 02/92.42.706 Tel. 02/92.42.706 Web Site: www.pelazza.com
More informationDE ES A A. For Modernisation and New Installation L1000A L1000A L1000A
lift Inverter Series L1000A EN DE ES FR IT A1000 1000A L1000A L1000A L1000A For Modernisation and New Installation Yaskawa L1000A for High Performance Lift Application Contents Page 2 Experience & Invation
More informationPhysical Specifications
General In This Section Standard Enclosures Landing Systems Load Weighers TLS Switches Physical Specifications General This section is intended to be used as a reference for physical specification of products
More informationOpen Chassis Star-Delta Starter User Guide
Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...
More informationLIFT INVERTER SERIES L1000A
LIFT INVERTER SERIES L1000A EN DE ES FR IT For Modernisation and New Installation YASKAWA L1000A FOR HIGH PERFORMANCE LIFT APPLICATION Contents Page 2 Experience & Innovation Page 3 Main Features Page
More informationUser Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736
User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer
More informationBx OVEN ECOTOUCH CONTROL
www.monoequip.com Bx OVEN ECOTOUCH CONTROL SPARES MANUAL ALL MODELS When ordering spares please quote the machine serial number which can be found on the silver information plate of the machine and on
More informationAutomatic control. of the doors. 99 VF Evolution
Page 1/12 Automatic control of the doors SUMMARY Page 2/12 A - General information...................................................... p.3 B - Data...................................................................
More informationOPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO
OPERATING INSTRUCTIONS ASTRO HOIST Type E89-CTO CONFORM TO EN 1808 - MARCH 1999 MACHINE DIRECTIVE 98/37 EC All persons operating this equipment must read and completely understand this manual. Any operation
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9
USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.
More informationWith know-how to the top! ZIRCON. Machineroomless lift
With know-how to the top! ZIRCON Machineroomless lift ZIRCON Machineroomless lift Features at a glance Type certified in accordance with lift directive 95/16/EU and EN81-1 / A2:2004 Duty loads from 320
More informationStandard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes
More informationREVISION HISTORY REVISION HISTORY
FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim
More informationPOWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
More informationOperating Instructions Pedestrian Turnstile Type MPT 33
Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationOperating manual UPS - System
Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland
More informationParker AC10 Frequency Inverter (to 22kW) Easy Start Guide
Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide CAUTION: 1)Do not re-set while the motor is rotating 2)Perform parts replacement after discharge is finished 3)Do not connect output terminals
More informationDYNATECH D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM DYNAMICS AND TECHNOLOGY, S.L.
DYNATECH DYNAMICS AND TECHNOLOGY, S.L. D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM TABLE OF CONTENTS TABLE OF CONTENTS...- 1-1. INTRODUCTION....- 2-1.1 Description...- 2-2. RISKS AND SECURITY WARNINGS...-
More informationINSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH
Instr. No. 2650-887D INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH IMPORTANT WEAR SAFETY GLASSES 5 4 6 COPYRIGHT PATENT PENDING 3 7 8 PLAYBACK 9 2 0 1 AUTO METER PRODUCTS, INC. SYCAMORE, IL
More informationALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.
ALIEM USER MANUAL 2 19-04-2018 R. Bocconi REV. DATE Checked and Approved R. T. PAGE INTENTIONALLY LEFT BLANK 2 ALIEM 1000 USER'S MANUAL Version 2 dated 19-04-2018 1 INTRODUCTION ALIEM 1000 is an emergency
More informationAUTOMATIC 12 WAY HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationEclipse Gearless Residential Elevators OWNER S MANUAL
Eclipse Gearless Residential Elevators OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000846 22-m09-2011 2 IMPORTANT Ensure that only an Authorized Savaria
More informationVFD E Series. Features
VFD E Series Output Frequency : 0.1 ~ 600 Hz. Built in PLC Function 500 Step program in Ladder Language. Side by side installation. Easy maintenance. Modular & Compact Design. Built-in MODBUS communication.
More informationSDS Enclosed Star-Delta Starter User Guide
SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationTeaching equipment designer and manufacturer
Teaching equipment designer and manufacturer ELEVATORS MODULAR ELEVATOR: - COMPOSITION A LA CARTE - DIFFERENT TECHNOLOGIES OF CABINETS - DIFFERENT TECHNOLOGIES OF MECHANISMS OF DOORS - COMMON OPERATIVE
More informationContinuing Education Course #206 Introduction to Designing Machine Control Systems Part 2
1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material
More informationENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER
ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST
More informationAll you need is in the package Anything else?
2 3 4 All you need is in the package Anything else? 5 In 1980 In 1987 In 1994 In 1995 In 1997 In 2008 In 2015 In 2016 HAS Elevator started its business journey by producing rubber and plastic components
More informationELVORON HOME ELEVATOR
Creating An Accessible World ELVORON HOME ELEVATOR PLANNING GUIDE www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation
More informationGBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1
GBW22Y Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 Power Rating Standby power LTP kva 14.30 Standby power LTP kw 14.30 Prime power PRP kva 13.00 Prime power
More informationInfinity & Infinity HD
Infinity & Infinity HD Residential Elevators (with Micro-6 Controller) OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000842 30-m06-2017 2 IMPORTANT Ensure
More informationPart Diagrams. Post (typical) Stabilizing Wire Rope Assembly. Part Name Part Number HydraLift Models
Post (typical) Sprocket Kit, Upper Stabilizing Wire Rope Assembly Sheave Motor, Hydraulic Limit Switch Sprocket Kit, Lower Part Name Part Number HydraLift Models Limit Switch MX000778 all Motor, Hydraulic,
More informationVVVF-Inverter Type MFC Quick Check
Content and Quick Reference 1. Check of Elevator Specific Data at Inverter 2. Possible Errors and How to Put Them Right 3. Further Control Possibilities 4. Error Reports in Error Stack 5. VVVF-Inverter-Hotline
More informationPower Systems Trainer
Electrical Power Systems PSS A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilisation Key Features Simulates generation, transmission,
More informationREGAL-BELOIT SpinMaster AC Adjustable Speed Drives
REGAL-BELOIT SpinMaster Volts/Hertz Constant Torque, Micro Inverter Applications: Constant torque or constant horsepower applications. Typical applications include conveyors, packaging machinery, machine
More informationSD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool
FR VARIABLE SPEED DRIVES Regenerative Active Front End icool 4 QUADRANT POWER ELECTRONICS / SD700 SERIES FR SD700FR SERIES goes one step ahead keeping the family unique characteristics. Based on the latest
More informationWell dimensions are absolute min. plumbed dimensions. Shaft floor to be constructed in accordance to layout drawing
ISO-MAX 750/1000 KG Hinged doors Loading front and rear Machine above With safety gear Well dimensions are absolute min. plumbed dimensions Shaft floor to be constructed in accordance to layout drawing
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationCOMMERCIAL PASSENGER LIFTS
1/86 Forsyth Street, O Connor WA 6163 Office +61 8 9331 1004 Emergency +61 8 9324 4313 COMMERCIAL PASSENGER LIFTS TECHNICAL MANUAL Coercial Passenger Lifts Domestic Passenger Lifts Lift Interiors Lift
More informationNEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors
Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140
More informationELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243
ELECTRIC SCHEMATICS NOTES: (Unless otherwise specified). Switch S BASE/PLATFORM makes contact from the CENTER to the LEFT position when placed in BASE.. Switch S UP/DOWN makes contact from the CENTER to
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More information1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp
VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationGS2 Series - Introduction
GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase
More informationT-Sense _ 660. Optical Torque Measuring Systems. Product Bulletin
T-Sense Optical Torque Measuring Systems _ 660 Product Bulletin WWW.VAF.NL 1 Introduction The use of a T-Sense torque measuring system means efficiency improvement, overload protection and prevention of
More informationRVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a
4 319 2968 0 G2383en en Installation Instructions District heating controller for one heating circuit and d.h.w. RVD230 Installation Place of installation In a dry room, e.g. in the heat exchanger room
More informationDESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control
Owner s UM-01.26.001-USK All DRAFT KONE Montana 2011 rights Corporation KONE (-) guide reserved Elevator 2011-02-24 Corporation Project DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control All
More informationThe Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC
The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More information2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /
Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.
More informationGUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations
THE PEELLE COMPANY FREIGHT DOORS I CAR GATES I CAR ENCLOSURES GUIDE 200.V2 CONTROL SYSTEM & INTERFACE GUIDE 202 Standard Operation 202 Slave Mode 201 Sequence of Operations VSD VERTICALLY SLIDING DOORS
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationPower Plugs for Proportional Valves (12 volt supply)
VICKERS Accessories Plugs for Proportional Valves ( volt supply) EHH-AMP-7-D/G-* Series For use with valve types: KDGV-(S)-GP7-6* KTGV-(S)-GP7-6* KCG-/6/8-GP-* KX(C)G-6/8-GP-* KDG5V-5/7/8-GP-* CMX***-E-G
More informationMODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)
MODUL-CONNECT 1.2 Modular, digital wiring and control system Owner s Manual Document Part Number MSMC Rev 9 (04/18) Service Contact Information E-mail: info@modul-system.com Phone: +46 31 746 87 00 Web:
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationAA4006 Speed Sensitive Trip Unit. User Manual
AA4006 Speed Sensitive Trip Unit User Manual Software Version 2.00 Issued 01/2005 Don Controls Limited Westfield Industrial Estate Kirk Lane, Yeadon Leeds, LS19 7LX Telephone: +44 (0)845 1304946 Fax: +44
More informationMICROPROCESSOR SYSTEM EQMPP. Installation Manual. V 1.2 June 5 th ELETTROQUADRI S.r.l. Via Puccini, Bisuschio (VA) - Italy
MICROPROCESSOR SYSTEM EQMPP Installation Manual V 1.2 June 5 th 2018 ELETTROQUADRI S.r.l. Via Puccini, 1 21050 Bisuschio (VA) - Italy Phone +39 0332 47 00 49 e-mail: info@elettroquadri.net URL: http://www.elettroquadri.net
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More information