THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 DPL Building Courthouse Plaza Southwest Dayton, Ohio P.U.C.O. NO. 1
|
|
- Nathaniel Hubbard
- 6 years ago
- Views:
Transcription
1 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 15 SCHEDULE 1 Schedule of fees and charges used for determining sacrifice value, excess height and/or strength and sale costs of poles. Year % Set Condition Class All All All All All All All All All All All All All All All All All All All All All All
2 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 16 SCHEDULE 1 (Cont'd) Year % Set Condition Class All All All All All All All All All All PRIOR
3 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 17 SCHEDULE 2 Cost of miscellaneous repetitive items performed by Owner for the benefit of and at the expense of the Attachor. 1. Install 1" x 7' double-eye rod and 8" anchor. *If existing anchor is to be replaced, then add to the above amount. 2. Move 30' and shorter pole. 3. Move 35' and higher pole. (Items 2 and 3 apply only where the existing pole can be physically moved.) 4. Transfer Guy. 5. R/P (Replace) down guy. 6. Install pole to pole guy. 7. Move ground wire on existing pole. 8. Install wrap ground wire. 9. City permit-when pole is set for Attachor. 10. Restoring 1 square foot of concrete sidewalk or pavement in connection with setting a pole for Attachor. 11. Install guy insulator in existing guy. 12. Connect Attachor's aerial cable ground wire to Owner's neutral.
4 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 18 SCHEDULE 2 (Cont'd) 13. Attachor to connect ground wire from buried cable closure to Owner's vertical ground wire on Owner's pole. (This connection to be made approximately six (6) inches above ground line.) 14. Connect #6 ground wire from Attachor's buried cable closure to Owner's underground multigrounded neutral system. 14A. Crew off jobsite - first connection. 14B. Crew on jobsite - or after 1st connection of 14A above. 15. T (Transfer) or R (Relocate) secondary rack. 16. R/M (Remove) secondary rack. 17. I/S (Install) insulated bracket. 18. R/M insulated bracket. 19. T or R secondary crossarm-including pins and insulators. 20. T or R primary or arc circuit crossarm and brace. 21. T or R primary or arc circuit pin and insulator. 22. I/S primary or arc circuit crossarm and brace. 23. I/S primary or arc circuit pin and insulator. 24. R/M primary or arc circuit crossarm and brace.
5 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 19 SCHEDULE 2 (Cont'd) 25. R/M primary or arc circuit pin and insulator. 26. T or R primary pole top in and insulator. 27. I/S pole top pin. 28. R/M pole top pin. 29. T or R secondary conductor per conductor. 30. T or R secondary TX or QX conductor. 31. T or R secondary dead endall conductor types. 32. T or R primary or arc circuit conductor. 33. T or R primary or arc circuit dead ends on crossarms. 34. T or R primary or arc circuit vertical dead end. 35. T or R--2 of 3 wire--one end only--#2 conductors or smaller conductor (length adequate). 36. R/P service or street light drop.
6 THE DAYTON POWER AND LIGHT COMPANY Original Sheet No. 20 SCHEDULE 2 (Cont'd) 37. T or R street light fixture and mast arm. 38. T or R single phase transformer installation including protective equipment and mounting -- fused cutouts and arrester. 39. R/P cutout. 40. R/P arrester. 41. R/P cutout and arrester. 42. R/P 10</ riser -- includes cutout, arrester, terminator and 5' of #1/0, 2c cable. 43. I/S U-Guard. 44. Tree trimming -- per tree. 45. Shorten drip loops. 46. Transfer system cable. 47. Cost to remove pole when replaced for Attachor. 48. Estimated cost will be computed when necessary on items not listed above; such as transformer bank structure, primary or secondary cable risers and other special or unusual installations.
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING
SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING Obtain acceptance and specific details from the local Company office. 1. Service entrance duct (see Note 1). Company
More informationCustomer Requirements Clearance Requirements for Overhead Joint Utility Construction
Application This standard establishes the clearances that are required on utility pole structures between electrical supply facilities owned and operated by Tacoma Power and communication facilities owned
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationWhen power interruptions happen.
When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage
More informationBUSINESS PROCEDURE. January 1, 2015
PURPOSE To provide uniform charges and standard estimating unit charges for electric supply and service to all classes of customers as required and supported by other NB policies. SCOPE This pricing policy
More informationUNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.
UNDERGROUND SERVCE tems to consider f your trenching route has to be dug by hand, or if a cable must be installed under a paved surface, additional charges apply. f your service cable has to be moved later
More informationELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL
INTRODUCTION This policy has been adopted by the Board of Public Works as a guide to obtaining electric service and to set forth the services available, conditions for service, and standards for materials
More information34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE
4. METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE 4.-4 4. SELF-CONTAINED METERING, SINGE-PHASE INSTALLATION DETAILS /4 VOLT SINGLE-PHASE UNDERGROUND RESIDENTIAL SERVICE AND METER
More information7 Single Family Service
7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationSee NT POWERCOS , Classification Based On Service Size.
Newmarket-Tay Power Distribution Ltd. Conditions of Service Number: NT POWER COS 310 01 Issue Date: July, 2007 Next Review Date: February, 2020 Residential 1. Preamble This section covers all items that
More informationSpecifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)
Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS
More informationCONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION
Page 1 of 11 R1 ****This Standard Supercedes CE Macros MPR1S, MUR1S, MPR3S & MUR3S and portions of BECo Standards CS2.7-1.1, CS2.7-1.5 & CS2.7-1.7**** PRIMARY URD RISER CONSTRUCTION TABLE OF CONTENTS Page
More information7. Residential Single-Family and Duplex Buildings (Dwellings)
Sin g le -F a mily a n d Du p le x Bu ild in g s 2016 Electric Service Requirements, 2 nd Edition Section 7 Section 7 Residential Single-Family and Duplex Buildings (Dwellings) Directory Page 7.1 General
More information18E Albe Drive Newark, DE 19702
Completed Projects Project Location: Wildcat Point Generation Station Rising Sun, Maryland PCL Industrial Construction Billy Otis Cell (281) 889-0214 Email bcotis@pcl.com 1) Project Description: 34kV Electrical
More informationAMENDMENT ELECTRIC SERVICE MANUAL 2014
AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that
More informationUG FEEDING OH UG FEEDING OH. Electric Distribution Standards I. INTRODUCTION
I. INTRODUCTION Electric Distribution Standards Design, Construction & Material Standards formed a special committee to establish some basic design guidelines for construction alternatives to be used for
More informationD9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE
SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationADDENDUM No. 1 Prospective Bidders
Page 1 of 1 Attachment to Addendum # 1 Revised Itemized Bid ADDENDUM No. 1 TO: Prospective Bidders FROM: Gregory Tate, Construction Contracts Administrator DATE: January 24, 2019 PROJECT: Traffic Signal
More informationCommercial Electric Policy
Commercial Electric Policy 7/19/16 1 Table of Contents General Information..3 Construction.3 Ownership.4 Multi-Unit/Multi-Service Buildings....4 Secondary Termination Enclosures.4 Meter Bases.5 Temporary
More informationELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016
UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department
More informationALUMA FORM LIGHT WEIGHT MOUNTS FOR TRANSFORMERS
PRIMARY METERING MOUNT CATALOG ALUMA FORM LIGHT WEIGHT MOUNTS FOR TRANSFORMERS ALUMA-FORMprimary metering mounts All aluminum, light weight construction for mounting current and potential transformers
More informationAGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS
Prepared by: ABB1 AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS 05619 Asset Type: Electric Metering Function: Design and Construction Issued by: Lisseth Villareal (LDV2) Date: 07-31-15 Rev. #10: This
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationLight Weight Mounts for Transformers PRIMARY METERING MOUNTS
Light Weight Mounts for Transformers PRIMARY All aluminum, light weight construction for mounting current and potential transformers for primary metering hookups. Mount comes as shown ready to be made
More informationCABLE TERMINALS
14 00 00 01 Sheet 1 of 1 TABLE OF CONTENTS LOCATION & PLACEMENT OF RISERS ON JOINT USE POLES STANDOFF BRACKET PLACEMENT AND GROUNDING ONE RISER WITH U GUARD, 2, 3, 4, & 5 SPLIT CONDUIT OR SCHEDULE 40 0
More informationEngineering Rules and Regulations for Electric Service Platte-Clay Electric Cooperative, Inc.
Engineering Rules and Regulations for Electric Service Platte-Clay Electric Cooperative, Inc. December 2016 (Expires 9/30/18) Kearney Cooperate Headquarters 1000 W. 92 Highway Kearney, MO Platte City District
More informationINSTALL SERVICE- ENTRANCE SYSTEMS
SUBCOURSE EN5141 EDITION B US ARMY ENGINEER SCHOOL INSTALL SERVICE- ENTRANCE SYSTEMS INSTALL SERVICE- ENTRANCE SYSTEMS Subcourse Number EN5141 EDITION B United States Army Engineer School Fort Leonard
More informationAll territory within the incorporated limits of the City and land owned or leased by the City.
A. APPLICABILITY: This schedule applies to all connections, expansions, and upgrades to the City's Electric Distribution System except those that serve street lighting or traffic signals. B. TERRITORY:
More informationUNDERGROUND SERVICE ENTRANCE LOCATION. No meter base or entrance should be installed before an KREMC engineer has checked the proposed location.
UNDERGROUND SERVICE No meter base or entrance should be installed before an KREMC engineer has checked the proposed location. Entrance cabinet must be directly through wall or directly under meter in basement.
More informationTechnical Specification for Pole Mounted Capacitor Rack
Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to
More informationRISER POLES RISER POLES. Overhead Electric Distribution Standards INTRODUCTION
INTRODUCTION. For proper fuse coordination, refer to the SYSTEM PROTECTION section to select the appropriate fuse for underground risers.. Terminators or Potheads and their mounting brackets are included
More informationRolling Road (Route 638) Widening Project
Rolling Road (Route 638) Widening Project From: 0.369 Mile North of Fairfax County Parkway (Route 286) To: Old Keene Mill Road (Route 644) State Project No. 0638-029-156, P104, R204, C504; UPC 5559 Public
More informationSECTION 300 OVERHEAD SERVICE
SECTION 300 OVERHEAD SERVICE 300.01 General Company provides, installs, and maintains service drop to point of delivery approved by Company. Customer provides point of attachment which is acceptable to
More informationRESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS
SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated
More informationBaltimore Gas and Electric Company Electric -- Retail 57. Billing Watts Description Rate
Baltimore Gas and Electric Company Electric -- Retail 57 PRIVATE AREA LIGHTING ELECTRIC SCHEDULE P L AVAILABILITY: For unmetered outdoor area lighting of private property. MONTHLY RATES: 1. For supply
More informationMINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates
MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS Larry Vogt Manager, Rates Minimum Distribution System What is MDS? MDS is an analysis module of the cost-of-service study in which distribution investment
More informationEielson AFB Electrical Design Standard 09 September 2016
Eielson AFB Electrical Design Standards Page 1 Electrical Design Standard Electrical work includes, but is not limited to, the design of the following systems: Primary Electrical Distribution Systems,
More informationInstalling or Rebuilding Your Electric Service
Installing or Rebuilding Your Electric Service 2 3 Contents Policies for New and Rebuilt Electric Service 2-4 Paperwork and fees...2 Five-year policy...3 Proposed route location and conditions...3 Construction
More informationSYSTEM PROTECTION - PLATING
INTRODUCTION 1. Plates F1 thru F10 supply only the material required for one-phase. Therefore, for threephase construction, you will be required to call for the specified plate three times at that station.
More informationCustomer Requirements Pole Attachment Requirements for Telecommunications (non-rf)
Application This standard establishes the attachment requirements to utility pole structures owned and operated by Tacoma Power and communication facilities owned and operated by others. This standard
More informationOVERHEAD SERVICE. Items to consider
OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must
More information185mm-System power 2500A. Expertise
185mm-System power 2500A Expertise System advantages The 185mm-System power is designed for use in efficient power distribution assemblies with a high short-circuit withstand capacity. The narrow design
More informationTABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet
DRAWING NUMBER INTRODUCTORY INFORMATION Important Notices Underground Plant Protection Information Code Clearances Commercial/Industrial Information Sheet Work Management Customer Projects Engineering
More informationAlternating Current and Three-Phase Systems Annotated Instructor s Guide
Alternating Current and Three-Phase Systems Annotated Instructor s Guide Module 80201-11 Module Overview This module provides an introduction to the theory of alternating current, along with AC circuits,
More informationATTACHMENT E: CONSTRUCTION EQUIPMENT SUMMARY
ATTACHMENT E: CONSTRUCTION EQUIPMENT SUMMARY Equipment Use Improve Access Roads (per mile) Bulldozer Grade access roads 1 4 10 Road Grader Grade access roads 1 4 10 Loader Load haul trucks, transport materials
More informationResidential Application for New Electric Service
Attn: Engineering Department 42 Wescom Rd Johnson VT 05656 1-800-832-2667 ext. 1171 802-635-2331 ext. 1171 802-635-4210 fax Residential Application for New Electric Service INVOICE Attn: Engineering Department
More informationTransmission & Distribution Glossary of Electrical Terms
Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The
More informationJob Estimate Face Sheet (E) - 10/01/16 08:41
Project Name: Bay Rd East Palo Alto R20A Notification: 107830311 Address: BAY RD EAST PALO ALTO Order Type: E070 City/County: EAST PALO ALTO/Santa Clara PM Order Number: 31059780 Contact Name: SCOTT GARVEY
More informationJACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018
JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationPentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION
PULL BOX F SECONDARY SYSTEM Typical grade Pentahead bolts See note 2 Conduit run as specified Plastic or fiberglass for grass areas or Polymer concrete for light duty areas (see notes 2, 3, & 4) Company
More informationWisconsin Public Utility Institute. June 28, Minimum Distribution Charges. Larry Vogt. Director, Rates Mississippi Power
Wisconsin Public Utility Institute June 28, 2017 Minimum Distribution Charges Larry Vogt Director, Rates Mississippi Power 1 Costs of Service vs. Cost Recovery Residential Service Example Assuming that
More information$ homes in a subdivision. The Fee includes an S-1 Pedestal. $ homes in a subdivision. The Fee includes an S-2 Pedestal.
ELECTRIC, GAS AND WATER Sche edulee of Charges 2017 MEMPHIS LIGHT, GAS AND WATER DIVISION MEMPHIS, TENNESSEE MEMPHIS LIGHT, GAS AND WATER DIVISION ELECTRIC SCHEDULE OF CHARGES Effective JANUARY 2017 A.
More informationSTATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013
Safety Services 16 th floor, Commerce Place Tel: 1-866-421-6929 10155 102 nd Street Fax: 780-427-8686 Edmonton, Alberta Canada T5J 4L4 STATISTICS ELECTRICAL INCIDENTS IN ALBERTA January 1 to December 31,
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationReview of Electric Utility Hurricane Preparedness and Restoration Actions ORLANDO UTILITIES COMMISSION RESPONSES TO STAFF'S SECOND DATA REQUEST
BEFORE THE FLORIDA PUBLIC SERVICE COMMISSION In re: Staff's Second Data Request on OUC' s Review of Electric Utility Hurricane Preparedness and Restoration Actions Docket No. 20170215-EU Filed: January
More informationGUIDELINES FOR RESIDENTIAL ELECTRIC SERVICE HOOKUP
GUIDELINES FOR RESIDENTIAL ELECTRIC SERVICE HOOKUP Residential Guidelines Revised 05/04/2016 Page 1 Table of Contents How Do I Get Power To My Property?... 3 Important Contact Numbers... 4 Process for
More informationPRODUCTS FOR THE RAIL AND UTILITY INDUSTRY
PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success
More informationSINGLE PHASE WIRING SPECIFICATIONS
SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationTHREE PHASE WIRING SPECIFICATIONS
THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationA. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.
SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationTable of Contents. Electrical Service Requirements. 1. General Requirements
Table of Contents 1. General Requirements 1.1 General Definition.................................................... 1 1 1.2 Booklet Purpose and Organization....................................... 1-1
More informationT YPE MZ DISTRIBUTION S TANDARD CUTOUT
T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal
More informationPretest Module 29 High Voltage Unit 1
Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition
More informationStreet Lighting Request Policy. City of Orting Washington June 16, 2015
Street Lighting Request Policy City of Orting Washington June 16, 2015 POLICY FOR WHICH ADDITIONAL LIGHTING REQUEST FOLLOWS CITY OF ORTING BUILDING STANDARDS & OMC I. Policy Objective The objective of
More informationIndex Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles
103 09-17 103 Index Section 103 Joint Use Title Date Number General Requirements for Installation of Attachments on Oncor Poles... 103-100 Supply and Communication Space... 103-105 Communication Lines
More informationPoles - General Unguyed Single Phase Composite Poles Poles - General Unguyed Three Phase Composite Poles
Standard Description 2 4 2 Poles - General Unguyed Single Phase Composite Poles 2 4 3 Poles - General Unguyed Three Phase Composite Poles 3 3 Structural Elements - Design Limits 3 1 1 Configurations -
More informationPART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10
PH1 Offset Pole Band Bands Single Double Offset Pole Bands are used for dead-ending, guying, and mounting secondary racks on metal poles, pipe masts, or conduit. Each Pole Band Assembly contains two 1
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities - Controlling Revised
Truck Module Page 1 of 6 CONTROLLING UTILITIES Emergency Operations One of the initial tactical priorities for the incident commander of a structure fire is to secure the building utilities to insure the
More informationPRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)
Please indicate which products and services your company can supply by checking the appropriate box(es). Check only the first box if your company can supply all of the products and services shown for this
More informationCITY OF ESTHERVILLE, IOWA MISCELLANEOUS FEES & CHARGES. At Sewer Main.. $
CITY OF ESTHERVILLE, IOWA MISCELLANEOUS FEES & CHARGES Revised 4-6-09 UTILITY FEES Sanitary Sewer Taps: At Manhole... $ 400.00... At Sewer Main.. $ 500.00... All excavation, labor and materials by property
More informationSurface Regulations and Policies
Surface Regulations and Policies COAL FATALITIES 1970-2002 350 300 250 200 150 100 50 0 1970 1973 1976 1979 1982 1985 1988 1991 1994 1997 2000 From January 1, 1970 through today, a total of 240 coal miners
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationPublished 2018 RULES AND REGULATIONS FOR ELECTRIC SERVICE
Published 2018 RULES AND REGULATIONS FOR ELECTRIC SERVICE TABLE OF CONTENTS Page No. SECTION I INTRODUCTION 1 A. PURPOSE 1 B. SCOPE 1 C. CORPORATION 1 D. CODES 1 E. RESPONSIBILITY 1 F. INSPECTION 2 G.
More informationPUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY
Fees and Charges PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY 1 SECTION TABLE OF CONTENTS Fees and Charges PAGE TABLE OF CONTENTS... 2 DELEGATED AUTHORITY... 3 ELECTRICAL FEES AND CHARGES... 4 SERVICE
More informationENTRANCE EQUIPMENT ER D PAGE 1 OF 5
PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument
More informationNew Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI
New Service Guidelines and Diagrams From... BARRON www.barronelectric.com email: janderson@barronelectric.com Barron Office: P.O. Box 40 Barron, WI 54812-0040 Spooner Office: P.O. Box 261 Spooner, WI 54801-0261
More informationOSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)
OSHA Update Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926) 5/14/2014 Significant Changes to the Standards General Training Host Employer & Contractor Responsibilities
More informationURD Mini Pillar Installation Guide. UDS Universal Pillar Installation Guide. Cable to LV Isolators, Crossarm and Cable Detail
Part 5 LV Underground Drawing Register Number U8 U9 Description URD Mini Pillar Installation Guide UDS Universal Pillar Installation Guide U10-1 UDS Universal Pillar Double Link Unit Drilling Detail U10-2
More informationNEW SERVICE HANDBOOK
NEW SERVICE HANDBOOK LOCATING UNDERGROUND UTILITIES CHECK SHEET cut here Will you be working within ten feet of any overhead power lines? Yes No Type of work Work being done for County Nearest City Address
More informationSURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION
Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationSTANDARD DRAWING INDEX
ATTACHMENT B STANDARD DRAWING INDEX DESCRIPTION EXISTING DRAWING NO. GENERAL Typical Layout for Improvement Plans City of Stockton Standard Border and Title Block for 8 1/2 x11 Sheet City of Stockton Standard
More informationPUB-NP-067 Supply Issues and Power Outages
Requests for Information PUB-NP-067 Supply Issues and Power Outages on the Island Interconnected System 1 2 3 4 5 6 7 8 9 10 Q. Please provide electronic documents describing overhead and underground distribution
More informationSECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes metal-enclosed,
More informationLABOR OPERATIONS
17 00 00 01 TABLE OF CONTENTS RECONDUCTORING 4KV LOOPOVER AND SWITCH POLE RECONDUCTORING CROSSARM OR ARMLESS 1, 2, AND 3 PHASE RECONDUCTORING ANGLE OR DEADEND RECONDUCTORING FLOATING ANGLE RECONDUCTORING
More informationSTOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION
CHAPTER 1 - GENERAL INFORMATION 100. Purpose 101. Codes and rules 102. Continuity of service 103. Frequency, Voltage, and Amperage Limitations 104. High voltages 105. Unusual capacity requirements 106.
More informationSurge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets
Surge Arresters Surge Arrester/Type L use ombination Electrical Apparatus 235-26 escription ooper Power Systems surge arrester/type L interchangeable fuse cutout combinations are available in a wide variety
More informationWPS SERVICE MANUAL. Section Amp and Smaller - Common
Revised 01/2017 Section 2 200 AMP AND SMALLER - COMMON Page 1 of 17 Section 2 200 Amp and Smaller - Common 2-0 General Metering Requirements... 2 2-1 Basic Calculations... 4 2-2 100-200 Amp Single-Phase
More information12. ILLUSTRATIONS 12.1 GENERAL
12. ILLUSTRATIONS 12.1 GENERAL Illustrations of typical service equipment and installations are shown in this section as an aid to interpretation of these Electric Service Requirements. The illustrations
More informationPrivate Overhead Electric Lines. Safety and Responsibility
Private Overhead Electric Lines Safety and Responsibility 1 November 2012 Are your Private Overhead Electric Lines Safe? They are your responsibility to maintain. Customer Service Centre 1300 131 871 Faults
More informationLIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016
No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979
More informationPROTECTION OF THE BRANCH CIRCUIT
PROTECTION OF THE BRANCH CIRCUIT Branch circuit should always be protected from over current. Hence, an overall current devices shall be installed in all branch circuitries. Function of the over-current
More informationRevised: April 2018 ¹ SERVICE TO WIRELESS DEVICE ANTENNA ATTACHMENTS ON CUSTOMER SERVICE POLES (SHEET 1) CUSTOMER: 1. An overcurrent protective device including a disconnect switch shall
More informationCOMMERCIAL QUICK REFERENCE
COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR
More informationPre Proposal Meeting Hold Bay 4 Reconstruction and Reconfiguration. July 10, 2018
Pre Proposal Meeting Hold Bay 4 Reconstruction and Reconfiguration July 10, 2018 Hold Bay 4 Reconstruction and Reconfiguration Project Overview HOLD BAY 4 4 POSITIONS 2 Site Access, Haul Routes, and Storage
More information