CEP7-E ELECTRONIC MOTOR PROTECTION RELAYS

Size: px
Start display at page:

Download "CEP7-E ELECTRONIC MOTOR PROTECTION RELAYS"

Transcription

1 CEP7-E ELECTRONC MOTOR PROTECTON RELAYS MOTOR PROTECTON WTH LEADNG EDGE TECHNOLOGY, EXPANDABLE PROTECTON AND COMMUNCATON. MOTOR CONTROL Sales 3 NHP NHP nhp.com.au

2 The new CEP 7 overloads now boast a formidable range of smart add-on modules: CONTACTOR SELECT PHONE APP CEP 7-ERR remote reset module CEP 7-EGJ ground fault / jam protection and remote reset module CEP 7-EJM jam protection and remote reset module New contactor and overload selection tool Calculates full load current of 3-phase motors based on. kw Voltage (45, 69 and VAC) Selection made easy by providing part numbers and product photo. AVALABLE FROM THE TUNES APP STORE NOW! CEP 7-EPT PTC thermistor relay and remote reset module Contents CEP 7-EGF ground fault protection and remote reset module Side mount modules also deliver entry level communication with DeviceNet TM, Profibus and Ethernet / P: CEP 7-EDN DeviceNet TM communication module - available for fully adjustable jam / stall protection and thermal warning to indicate imminent overload trip CEP 7-EPRB Profibus communication module includes warning for jam trip, overload and underload. ncludes device trip and warn status CEP 7-ETN Ethernet / P communication module with builtin webserver support for configuration and monitoring CEP 7-DNCT - hand held programming terminal includes one metre cable to be used with CEP 7-EDN (DeviceNet TM module) For further information visit: nhp.com.au/s+s ntroduction to CEP 7 electronic overload relays...[3, 4] CEP 7-ED standard electronic overload relays...[5] Overview of CEP 7-EE features...[6] CEP 7-EE enhanced electronic overload relays...[7] CEP 7-E_P pass through electronic overload relays...[8] CEP 7 side mount modules...[9] CEP 7-CBCT core balance transformers and communication modules...[] Accessories...[, 2] CEP 7 quick reference guide...[3, 4] Dimensions...[5, 6] CEP 7 module technical information...[7-9] CEP 7-ETN Ethernet Network Communication Module...[2] CEP 7-CBCT core balance transformers (technical information)...[2-24] Trip curves...[25] Technical information...[25, 26] 2

3 Electronic overload relays Modular in design, clever in application The new CEP 7-EE overloads now offer a formidable range of smart add on modules. These small side mounted plug-in modules extend the CEP 7 capability to something more potent in terms of motor protection. Communication modules are also available. 27 A CEP 7 comprehensive motor protection Sprecher + Schuh have introduced their new CEP 7, second generation electronic overload protection relays. The new CEP 7 overloads incorporate a greater use of sophisticated electronic control and monitoring. With recent advances in micro electronic technology and the introduction of the ASC chip set, it has become possible to improve on and add new features to the popular CEP 7 range. The CEP 7 second generation overload now incorporates greater accuracy and versatility whilst providing increased overall protection. R O B U S T M O U N T N G to co n tac to r CEP 7-EPRB Profibus communication module CEP 7-EDN DeviceNet TM communication module CEP 7-ETN EtherNet / P communication module CEP 7-ERR Remote reset module CEP 7-EJM Jam protection and remote reset module CEP 7-EE + EDN DeviceNet TM 45 A 9 A 8 A The new CEP 7 incorporates the following improved features: A wider settable current range (5:) Adjustable class trip settings (, 5, 2 and 3) (EE version) Field installable side mount modules (EE version) An extremely low power consumption of 5 mw Robust mounting to contactor. Range overview CEP 7-ED basic model The CEP 7-ED is the standard or base model version. The ED model is available in the current range of A, incorporates a fixed trip class of, and is suited to 3 phase operation. A manual reset function, visible trip indicator and test / reset button are also included. CEP 7-EE enhanced model The enhanced CEP 7-EE variant covers an operating range of. - 8 A with adjustable trip class settings of, 5, 2 and 3 (via dip switch selection). The EE model can be further enhanced by the addition of side mounted plug-in modules. CEP 7-E_P pass through model For current ranges - 27 A a version is available that mounts separate from the contactor. The motor wires pass through CT openings. Superior phase failure protection Onboard electronics constantly monitors all motor phases. f the ASC chip set senses that one or more of the phases is missing during a steady state operation of a fully loaded motor, it will trip in 3 seconds. f a single phase condition is present during starting, the CEP 7 will trip within 8 seconds (for a motor loading of > 8 %). These trip times are significantly faster then conventional bimetal overloads. n addition, the CEP 7 relay detects a 5 % phase imbalance in the same way as a phase loss. Rated up to VAC Dip switch settings (EE version) CEP 7-EPT PTC thermistor relay and remote reset module CEP 7-EGF Ground fault protection and remote reset module CEP 7-EGJ Ground fault / jam protection and remote reset module CEP 7-ERD Remote indication module (works with any side module ) Electronic overload relays for 3 phase motor applications to EC 6947 CEP 7 ED/EE/E_P x x Product type MODEL CURRENT RANGE OF SNGLE PHASE MOTORS current Range of three phase motors Code to suit CA 7 / CA 6 contactors CEP 7 = 3 phase ED = Basic model 3) P =...5. amps Rated Voltage: 69VAC B = CA CEP 7S = phase EE = Enhanced model R = amps A =...5 amps D = CA EE_P = Enhanced pass S = amps B =.2... amps E = CA through 2) T = amps C =...5. amps F = CA U = amps D = amps G = CA E = amps H = CA ) F = amps G = amps V = amps Rated Voltage: VAC H = amps J = amps K = amps L =...5 amps M = amps N = amps CEP 7-EE + EPRB Profibus NOTE: ) Not compatible with communication modules 2) Complies to EC-6997 for nominal operation voltage of volts. Only available in 3 Phase. Current range options available are C, D and E only. 27 A Rated to VAC with V rated insulation cables 3) Only available in 3 Phase. Current range options available are A, B, C, D, E and F only. 4) Rated up to 69 VAC 3 4

4 CEP 7-ED standard electronic overload relays Overview of CEP 7-EE features Electronic overload relays for 3 phase motors to EC 6947 moulded power connectors contactor connecting mechanism Manual reset, trip class - standard. 45 amps 5 : current adjustment range test button reset button Low power consumption (5 mw) Self powered Visible trip indicator mechanical trip test dip switches CEP 7-EPRB N/C trip contact and N/O alarm contact Direct mounting to CA 7 contactors up to CA trip status indicator fla setting dial manual reset class approx kw range current setting range (a) to suit contactor Cat No CA 7-9/2/6/23 CEP 7-EDAB control terminals load terminations CA 7-9/2/6/23 CEP 7-EDBB CA 7-9/2/6/23 CEP 7-EDCB CA 7-9/2/6/23 CEP 7-EDDB CA 7-9/2/6/23 CEP 7-EDEB CA 7-3/37/43 CEP 7-EDFD Communication options with add-on modules -EE versions from. - 8 A can be fitted with side accessories ( per overload). n the case of fieldbus communication side modules, they provide the possibility to control the contactor or collect inputs over the fieldbus network. Further, it then becomes possible to monitor trips, warnings and motor operating parameters. CEP 7-EDN Profibus - CEP 7-EPRB Electronic overloads for single phase applications to EC 6947 Same features as above, plus: Optional jam / stall and ground fault protection module Selectable auto / manual reset. Supports DP-V and DP-V Auto-band up to 2 MB/s DeviceNet TM - CEP 7-EDN Can also be stand alone programmed using CEP 7-DNCT programmer SNGLE PHASE Approx kw range current setting range (a) to suit contactor Cat No CA 7-9/2/6/23 CEP 7S-EEPB CA 7-9/2/6/23 CEP 7S-EERB CA 7-9/2/6/23 CEP 7S-EESB CA 7-3/37/43 CEP 7S-EETD CA 7-6/72/85/97 CEP 7S-EEUE EtherNet/P - CEP 7-ETN Built-in webserver support for configuration and monitoring All communication modules add the following features: Overload warning Jam trip and warning Overload warning 2 inputs CEP 7-ETN Wiring diagrams output Diagnostics: - % thermal utilised - Average current % FLA - Device status - Trip and warn status 3 phase CEP 7-ED/EE/E_P Single phase CEP 7S-EE/E_P 5 6

5 auto / manual reset class, 5, 2 or 3 CEP 7-EE enhanced electronic overload relays ) CEP 7-E_P pass through electronic overload relays Electronic overload relays for 3 phase motors to EC 6947 Auto / manual reset, trip class, 5, 2 or 3 - enhanced. to 8 amps 5 : current adjustment range Direct mounting to CA 7 and CA 6 contactors The CEP 7-E_P versions provide additional application flexibility and are designed to be mounted separately from the contactor. The motor wires are simply passed through the CT openings in the device and straight to the contactor which reduces the number of connection points. This makes them ideal in retrofit applications and when used with contactors other than CA 7 or where space is restricted. The P version can be fitted directly onto DN rail to speed up assembly. The EE_P version can also accept any of the side mount accessories including the communication modules; Devicenet TM, Profibus or Ethernet / P. CEP 7-EEAB Self powered Low power consumption (5 mw) N/C trip contact and N/O alarm contact Visible trip indicator Enhanced model The pass through version of the CEP 7 permits separate mount of the overload relay. CEP 7-EEGE Selectable manual reset Adjustable trip class, 5, 2 and 3 Optional DeviceNet communication module Optional Profibus communication module Optional EtherNet / P communication module Optional jam / stall and remote reset module Cat No. current setting range (a) control terminal wire variable control terminal torque variable trip class Rated Operation Voltage: Volts AC ) CEP 7-EECP mm 2.55 Nm -3 CEP 7-EEDP mm 2.55 Nm -3 CEP 7-EEEP mm 2.55 Nm -3 Optional PTC thermistor relay and remote reset Optional ground fault protection and remote reset. approx kw range current setting range (a) to suit contactor Cat No. CEP 7-EEJF Rated Operation Voltage: 69 Volts AC CA 7-9/2/6/23 CEP 7-EEAB CA 7-9/2/6/23 CEP 7-EEBB CA 7-9/2/6/23 CEP 7-EECB CA 7-9/2/6/23 CEP 7-EEDB Motor load side cables simply pass through a window in the overload relay body. The internal current transformers monitor the current flow CA 7-9/2/6/23 CEP 7-EEEB CA 7-3/37/43 CEP 7-EEED CA 7-3/37/43 CEP 7-EEFD CA 7-6/72/85/97 CEP 7-EEGE CA 7-6/72/85/97 CEP 7-EEVE Rated Operation Voltage: Volts AC CA 6-5/4/8 CEP 7-EEHF CEP 7-EEJG 22 2 ) 4 2 CA 6-5/4/8 CEP 7-EEJF CA 6-2/25/3/42 CEP 7-EEJG CA 6-2/25/3/42 CEP 7-EEKG CA 6-2/25/3/42 CEP 7-EELG CA 6-63/86 CEP 7-EEMH CA 6-63/86 CEP 7-EENH NOTE: ) EE versions can be fitted with side mount accessories - refer pages 9- NOTE: ) With V rated insulated cables. CEP 7-EEMH 7 8

6 CEP 7 side mount modules ) Accessory Description to suit Cat No. Remote reset module Provision for reset after trip from remote pilot device or CEP7-ERD CEP7-ERR CEP 7-CBCT core balance transformers for CEP 7-EGF / EGJ Ground fault current is sensed by passing all lines carrying current to and from a motor through the window of a special core balance current transformer often called a toroid / ground fault sensor. f all the current to the motor returns through the lines in the toroid, no significant current will be induced in the toroid secondary. f, however, ground fault current returns via a path external to the toroid, such as via the conduit walls, a current will be induced in the toroid secondary. This current will be sensed and amplified by solid state circuits. f the ground fault current is larger than the selected ground fault trip level of the overload relay, the overload relay will trip. CEP 7-ERR sensor type Approx. Current Rating inside diameter max rec. cable 6 V typical use with contactor size Cat No. CEP 7-EJM CEP 7-EPT CEP 7-EGF CEP 7-EGJ Jam protection and remote reset module Dip switch adjustable jam protection - Jam set points - 5 %, 2 %, 3 %, or 4 % FLA - Trip delay -.5,, 2, or 4 sec. Provision for reset after trip from remote pilot device or CEP7-ERD PTC thermistor relay and remote reset module PTC protection and LED status indication Type of control unit Mark A Number of sensors 6 Maximum cold resistance of sensor chain 5 Ω Trip resistance 34 Ω ± 5 Ω Reset resistance 6 Ω ± 5 Ω Short circuit trip resistance 25 Ω ± Ω Open circuit trip resistance > 2, Ω Maximum voltage at T / T2 (Rptc=4 k Ω) < 7.5 V DC Maximum voltage at T / T2 (Rptc=open) < 3 V DC PTC response time 5 8 ms Provision for reset after trip from remote pilot device or CEP7-ERD 2) 3) Ground fault protection and remote reset module Dip switch adjustable ground fault protection > GF current range set points - 2 ma - 5 ma -.2. A A > GF trip level 2 % - % LED status indication Provision for reset after trip from remote pilot device or CEP7-ERD Must use with CEP 7 - CBCT current sensor 2) 3) Ground fault/jam protection and remote reset module Dip switch adjustable ground fault protection same as CEP 7-EGF shown above Jam trip when the motor current exceeds 4 % FLA setting when enabled LED status indication Provision for reset after trip from remote pilot device or CEP7-ERD Must use with CEP 7 - CBCT current sensor _ CEP7- EJM CEP 7-EPT CEP 7-EGF CEP 7-EGJ 45 A 9 mm mm 2 ) CA CA 7-43 CEP 7-CBCT 9 A 4 mm 35 mm 2 ) CA CA 7-85 CEP 7-CBCT2 8 A 64 mm 2 mm 2 ) CA 6-8 CEP 7-CBCT3 42 A 82 mm 85 mm 2 ) CA 6-42 CEP 7-CBCT4 86 A 6 mm 3 mm 2 ) CA 6-86 CEP 7-CBCT5 Communication modules description to suit Cat No. Ethernet / P communication module ncludes warning for jam trip, overload and underload nputs/outputs - 2 inputs (24 V DC rated) - output relay (B3 rated) - status indication LED Monitoring - % thermal utilised - average current % FLA - device, trip and warn status Profibus communication module ncludes warning for jam trip, overload and underload nputs/outputs - 2 inputs (24 V DC rated) - output relay (B3 rated) - status indication LED Monitoring - % thermal utilised - average current % FLA - device, trip and warn status DeviceNet communication module DeviceNet Hand Held Programmer HM 2) Programming terminal includes m communication cable To be used with CEP 7-C/C2/C3 and CEP 7-EDN module NOTE: ) Side mount modules must have V, Hz or DC applied to terminals A and A2 for control power 2) Attention: The CEP 7 overload relay is not a ground fault circuit interruptor for personnel protection NOTE: ) With a 3 phase system with one cable per phase 3) Must be used with core balance transformer - refer page 2) Can be used on any DeviceNet TM product or network. Compatible with CEP 7C 9 CEP 7-ETN CEP 7-EPRB CEP 7-EDN CEP 7-DNCT

7 Accessories Accessory Description For use with Cat No. Accessory Description For use with Cat No. DN-rail / panel adaptor For separate mounting of overload relay to backpan or top hat DN-rail Current adjustment shield Prevents inadvertent adjustment of the current setting CEP 7-ED_B _B CEP 7-EE D CEP 7-EE E CEP 7-EPB CEP 7-EPD CEP 7-EPE CEP 7-BC8 Remote indication and reset module ) Panel mounted P 66 uses 22.5 mm fixing hole. t must be used in conjunction with a side mount module and connects via two wires to the remote reset terminals R and R2. ndication LEDS Power Overload Trip (solid) Warning (flash) Phase loss Module specific LED - ground fault, PTC, jam CEP 7-ERR CEP 7-EJM CEP 7-EPT CEP 7-EGF CEP 7-EGJ CEP 7-ERD NOTE: ) Must be used with side mount modules. Not compatible with communication modules External reset button adaptor Provides a larger target area for resetting the overload relay when using an external reset button CEP 7-ERA Display Status Module power (GREEN, flash) Module power & motor current (GREEN, solid) Hardware fault (RED, solid) Works with CEP7-EE Overloads from. to 8 Amps External reset button Manual reset pushbutton used for resetting overloads mounted in enclosures. To be used with CEP 7-ERA D7P-R6 Phase Loss LED Trip (RED, solid) Overload Conditions LED Trip (RED, solid) Warning (YELLOW, flash) Reset rod To suit D7 external reset pushbutton (D7P-R6) and CEP 7-ERA adaptor D7-ATR8 Adjustment cover for external modules CEP 7-EMC Module Fault LED Ground fault trip (RED, one flash) Jam trip (RED, two flashes) PTC trip (RED, three flashes) Fault detected (RED, rapid flash) Remote Reset P 66 rated Remote reset solenoids 24 V AC V AC 24 V AC 24 V DC 48 V DC V DC CEP 7-EMRJ CEP 7-EMRD CEP 7-EMRA CEP 7-EMRZ24 CEP 7-EMRZ48 CEP 7-EMRZ Dimensions (mm) nstallation metre communications cable with micro-connector CEP 7-DNCT CEP 7-CM metre communications cable with bare leads (included with the CEP 7-DNCT) CEP 7-DNCT CEP 7-BC Door / panel mount bezel kit CEP 7-DNCT CEP 7-DNCT - BZ 2

8 CEP 7-EE CEP 7-EE CEP 7 QUCK REFERENCE GUDE Motor protection CEP 7 overload relays NHP have introduced the new Sprecher + Schuh CEP 7, second generation electronic overload protection relays. The new CEP 7 overloads incorporate a greater use of sophisticated electronic control and monitoring. The CEP 7 second generation overload now incorporates greater accuracy and versatility whilst providing increased overall protection. CEP 7 side mount modules Current setting range (A) CEP 7-EEJG CEP 7-EEKG CEP 7-EELG...5 CA 6 ( VAC) Current setting range (A) CEP 7-EEMH CEP 7-EENH Amps kw 9 4 CEP Quick Reference Guide Standard electronic overload relays for 3 phase motors Current setting range (A) CEP 7-EDAB...5 CEP 7-EDBB.2... CEP 7-EDCB CEP 7-EDDB CEP 7-EDEB CA 7 (69 VAC) Enhanced electronic overload relays for 3 phase motors Current setting range (A) CEP 7-EEAB...5 CEP 7-EEBB.2... CEP 7-EECB...5. CEP 7-EEDB CEP 7-EEEB Features: Auto/manual reset Adjustable trip class, 5, 2 and 3 5: current adjustment range Self powered Low power consumption (5 mw) Direct mounting to CA 7 contactors N/C trip contact and N/O alarm contact Visible trip indicator Optional side mount modules Features: Manual reset Trip class 5: current adjustment range Self powered Low power consumption (5 mw) Direct mounting to CA 7 contactors N/C trip contact and N/O alarm contact Visible trip indicator CEP 7-ED CEP 7-EE Remote reset module CEP 7-ERR Jam protection and remote reset module CEP 7-EJM PTC thermistor relay and remote reset module CEP 7-EPT Ground fault protection and remote reset module CEP 7-EGF Ground fault/jam protection and remote reset module CEP 7-EGJ Current setting range (A) CEP 7-EEHF CEP 7-EEJF kw Amps Current setting range (A) CEP 7-EEGE CEP 7-EEVE Current setting range (A) CEP 7-EEED CEP 7-EEFD Electronic overloads also available for single phase applications to EC Current settings from...9 amps. See page 6. Electronic overloads CEP 7-E_P pass through version also available. See page 9. Electronic overloads CEP 7-C and CEP 7-C2 complete with communication (DeviceNet TM ). Current settings from amps. See NHP Part-A Catalogue for more details. Profibus communication module CEP 7-EPRB DeviceNet TM communication module CEP 7-EDN Ethernet / P communication module CEP 7-ETN CEP 7-EE CEP 7-EE CEP 7-EE

9 Dimensions (mm) Dimensions (mm) cep 7 mounted to CA 7 contactor (with side mounted module) cep 7-EEVF mounted to CA 6 contactor cep 7-EE_F...EE_H MOUNTED TO CA 6 CONTACTOR J H A 2 F CA6-] E K G B D Ø 5.6 RESET BUTTON TRAVEL: overload cat. No. contactor cat. No. C L mm a b c d e f g h j k l CEP 7*-EE_B CA 7-9/2/6/ CEP 7*-EE_D CA 7-3/ CA CEP 7*-EE_E CA 7-6/72/85/ CEP7 module technical information Overload cat. No. CEP 7-EE_F contactor cat. No. a Width Without terminal covers b Height With terminal covers B C Depth Reset d e e2 f g h j k m CA 6-5 (E) CA 6-4 (E) CA 6-8 (E) CEP 7-EE_G CA 6-2 E CA 6-42 E CEP 7-EE_H CA 6-63 E CA 6-86 E Wire size and torque specifications X 2X X 2X X 2X mm mm 2.55 Nm mm mm 2.55 Nm mm mm 2.55 Nm Connect remote reset pilot device to terminals R and R2. Do not apply external voltage to R and R2. Equipment damage will occur. Recommend use of twisted pair for remote reset,.2 mm 2 minimum. Apply V, Hz or DC to terminals A and A2 for control power. Rated insulation voltage (Ui) 3 V Rated operating voltage (Ue) V AC, 5/6 Hz V DC Power at rated operating voltage 24 V AC.3 W (Typical) 2 V AC.3 W 24 V AC.5 W Rated impulse withstand voltage (U imp) 2.5 kv Dynamic inhibit on start. A unique circuit within the CEP 7 protection modules monitors for motor starting inrush current. The circuit inhibits the protection feature during the motor start period and arms the protection function after the inrush current falls to motor rated current. This allows the motor to start and run, avoiding nuisance tripping during the inrush period. cep 7 pass through overload 5 NOTE: * No letter indicates 3 phase; S indicates single phase 6

10 Wiring diagrams Wiring diagrams CEP 7-ERR and CEP 7-EJM wiring diagrams CEP 7-ERR / EJM operational LED CEP 7-EJM dip switch CEP 7-EGF and CEP 7-EGJ wiring diagrams CEP 7-EGF operational LED CEP 7-EGF dip switch R2 R A2 A R2 R A2 A Apply V, Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7-ERD to terminals R and R2. Status LED Steady green - Module is powered up. Adjustment Settings Remote Reset SW Enable: Disable: Jam Protection SW2 Enable: Disable: Jam Trip Level SW 3 SW 4 5% 2% 3% 4% Jam Trip Delay SW 5 SW 6.5 sec sec 2 sec 4 sec R2 R S2 S A2 A S2 S A2 A R2 R Apply V, Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7-ERD to terminals R and R2. Connect current sensor to terminal S and S2. Status LED: Steady green - Module is powered up. Flashing LED - The number of flashes followed by a pause identifies the specific trip code as follows: () Flash - overload trip (2) Flash - phase loss trip (3) Flash - ground fault trip Fast flash - mpending trip ground fault detected and CEP 7 not yet capable of tripping. Steady red - Hardware fault. nternal hardware fault detected and CEP 7 trip attempted. Adjustment Settings Overload Relay Reset Mode SW Manual: Automatic: Ground Fault Current Range SW 2 SW m A...5 ma.2... A...5. A Ground Fault Trip Level SW 4 SW 5 SW 6 Disable/Off 2 % Max GF Current 35 % Max GF Current 5 % Max GF Current 65 % Max GF Current 8 % Max GF Current 9 % Max GF Current % Max GF Current SW7 SW8 Overload Relay Type 3 Phase: Phase: Not Used CEP 7-EPT wiring diagram R2 R T2 T A2 A R R2 Apply V, Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7-ERD to terminals R and R2. Connect terminal T and T2 to PTC chain. A2 A T T2 CEP 7-EPT operational LED Status LED Steady green - Module is powered up. Flashing LED - The number of flashes followed by a pause identifies the specific trip code as follows: () Flash - overload trip (2) Flash - phase loss trip (3) Flash - PTC trip (4) Flash - PTC open circuit (5) Flash - PTC short circuit Fast flash - mpending trip. PTC thermistor fault detected and CEP 7 not yet capable of tripping. Steady red - Hardware fault. nternal hardware fault detected and CEP 7 trip attempted. CEP 7-EPT dip switch Adjustment Settings ) Overload Relay and PTC Reset Mode SW Manual: Automatic: SW2 SW3 PTC Protection Enable: Disable: Overload Relay Type 3 Phase: Phase: NOTE: ) The delay between the occurrence of a PTC out-of-range fault and a trip of the CEP 7 varies, but is generally described by one of the following: CEP 7-EGF AND CEP 7-EGJ nstallation Ground Fault Sensor (CEP 7-CBCT) Control Wiring L L2 L3 Ground Fault Sensor Motor S S2 CEP 7 Overload Relay with Side Mount Module CEP 7-EGJ operational LED Status LED: Steady green - Module is powered up. Flashing LED - The number of flashes followed by a pause identifies the specific trip code as follows: () Flash - overload trip (2) Flash - phase loss trip (3) Flash - ground fault trip (4) Flash - jam trip Fast flash - mpending trip ground fault detected and CEP 7 not yet capable of tripping. Steady red - Hardware fault. nternal hardware fault detected and CEP 7 trip attempted. CEP 7-EGJ dip switch Adjustment Settings Overload Relay Reset Mode SW Manual: Automatic: Ground Fault Current Range SW 2 SW ma...5 ma.2... A...5. A Ground Fault Trip Level SW 4 SW 5 SW 6 Disable/Off 2 % Max GF Curren t 35 % Max GF Curren t 5 % Max GF Curren t 65 % Max GF Curren t 8 % Max GF Curren t 9 % Max GF Current % Max GF Current SW7 SW8 Overload Relay Type 3 Phase: Phase: Jam Protection Enable: Disable: 5 ms ± 25 ms, typical; - < 6 seconds, for a PTC out-of-range fault present at power-up of the side mount module. 7 - Under no conditions should a PTC trip take longer than 6 seconds. 8

11 Wiring diagrams CEP 7-EDN DEVCENET TM MODULE CEP 7-EPRB PROFBUS MODULE CEP7-ETN Ethernet Network Communication Module Connects to the network via RJ45 (Cat 5) connector. Supports /O and explicit messaging for data access by programmable automatic controller. Contains predefined ControlLogix style tags for direct software access. ncludes an integrated web server to allow users to read information and configure parameters via a computer web browser from remote locations. Uses a Simple Mail Transfer Protocol (SMTP) server to send or text messages in the event of a warning or trip condition. CEP 7-ETN ETHERNET / P MODULE EtherNet /P Communications TCP Connection 5 CP Connection 48 CP Unconnected Messages 28 /O Packet Rates 5/s Explicit Packet Rates 5/s Speed Duplex (Half/Full) / Duplicate P Detection Yes Offers ntegrated Web and Server View the status and events of your overload relay on the web at anytime, anywhere! The CEP7-ETN contains a web server to allow users to read information and configure parameters via the web. Uses a simple mail transfer protocol (SMTP) server to send or text messages in the event of a warning or trip condition. Electrical Power Supply Ratings Rated Supply Voltage 24V DC Rated Operation Range V DC Rated Supply Current.A Maximum Surge Current at Power-up 2.5 A Maximum Power Consumption W Output Relay Ratings Terminal OUT A 3/4 Type of Contacts Form A SPST-NO Rated Thermal Current 5 A Rated nsulation Voltage 3V AC Rated Operating Voltage 24V AC 3 A (@ 2V AC) Rated Operating Current.5 A (@ 24V AC).25 A (@ V DC). A (@ 22V DC) Minimum Operating Current ma (@ 5V DC) Rating Designation B3 Utilization Category AC -5 Resistive Load Rating (p.f..) 5 A, 25V DC 5 A, 3V DC nductive Load Rating (p.f. =.4), (L/R = 7 ms) 2 A, 25V AC 2 A, 3V DC Short Circuit Current Rating A 9 Recommended Control Circuit Fuse KTK-R-6 (6 A, 6V) 2

12 CEP 7-CBCT Core balance transformers Control wiring installation CEP 7-CBCT ground fault trip data The control wiring must be a twisted pair Lines in excess of one metre long must be a shielded pair with the shield connected to ground at only one point mportant: the shield, if present, of the twisted pair must be connected to earth ground at the sensor, with no connection made at the overload relay Maximum length is 3 metres for the shielded cable Sensor fastener torque Nm CEP 7-CBCT lead wires should be twisted before termination by applying one twist per inch CEP 7 overload RELAY WTH CEP 7-EGF or CEP 7-EGJ (CEP 7-EE) Power cable installation All power cables, including the neutral when used, must pass through the sensor window. The equipment ground conductor (the conductor used to carry the non-current carrying metal parts of equipment) must not pass through the sensor window. 2 The power cables, going through the sensor window, must be straight, tightly bundled, centred in the window, and perpendicular to the sensor for a length equal to or greater than six times the cable bundle diameter (including insulation) from the sensor (see Figure ). 3 All other conductors with available fault currents in excess of, A should be placed a distance equal to or greater than six times the cable bundle diameter (including insulation) from the sensor (see Figure 2). 4 The power cables of the branch circuit, to be protected by the overload relay, must not be grounded on the load side of the ground fault sensor. 5 f the power cables are enclosed in a conducting jacket, the jacket must be grounded on the line side of the sensor. The jacket must not pass through the sensor window, but must be cut at the window and joined with a conductor that passes outside the sensor window. 6 The power system must be solidly grounded or grounded through an impedance at the source, as long as the impedance allows for a magnitude of current to flow that is within the operational range of the overload relay. L L2 L3 CEP 7 overload RELAY WTH CEP 7-EGF or CEP 7-EGJ (CEP 7-EE) S S2 Motor Attention: the ground fault protection system is intended for equipment use only. This system is not a ground fault circuit interrupter for personnel protection. Ground fault trip delay The delay between the occurrence of a ground fault and a trip of the CEP 7 varies, but is generally described by one of the following: < 6 seconds, for a ground fault present at power up of the side mount module < 3 seconds, if the protection inhibit has not been cleared. Under no conditions should a ground fault trip take longer than 3 seconds Figure Figure 2 Attention: To prevent electrical shock, disconnect from power source before installing or servicing. nstall in a suitable enclosure, keep free from contaminants. Do not apply power to a system with power cables going through the sensor unless the sensor is connected to the overload relay. Operation without a low impedence connection to the secondary windings may result in damage to the sensor. 2 22

13 Locating phase conductors in the sensor window Dimensions (mm) Firmly secure the conductors in the centre of the sensor window so that they cannot be moved accidentally or under fault conditions CEP 7-CBCT Maintain as large a distance as possible between the bundled conductors and the wall of the sensor window For applications having one cable per phase, arrange the conductors per Figure A Ø 44.5 For applications having two cables per phase, arrange the conductors per Figure B. A spacer, having the same diameter as the conductors being used, should be used to separate the phase conductors Single cable per phase Two cables per phase Ø A B C C B A A B C spacer CEP 7-CBCT 2 and 3 E.8 A 44.5 C 3.2 Figure A Figure B Ø D 5.3 Attention: The ground fault protection system is intended for equipment use only. This system is not a ground fault circuit interrupter for personnel protection. F B An ideal core-balanced ground fault toroid responds only to the sum of the currents flowing through the sensor window, however, an actual core balanced transformer may saturate if the phase currents are too large. This results in ground fault sensor output even if the sum of the phase currents is zero. Saturation can be minimised by choosing a ground fault sensor with adequate core size and symmetrically locating the phase conductors in the centre of the sensor window as shown above. mm cat No. a b c Ø d e f CEP 7-CBCT CEP 7-CBCT CEP 7-CBCT

14 Trip curves ) Trip curve legend Cold trip Hot trip NOTE: ) Typical reset time for CEP 7 Second Generation devices set to automatic reset mode is 2 seconds Time (seconds) Time (seconds).. Technical information electromagnetic compatibility Trip Class FLA multiple Trip Class 2 FLA multiple Electrostatic discharge immunity Test level [kv] Performance level RF immunity Test level [V/m] Performance level Electrical fast transient burst immunity Test level [V/m] Performance level Surge immunity Test level [V/m] general Performance level Time (seconds) Time (seconds).. Trip Class 5 FLA multiple Trip Class 3 FLA multiple 8 kv air discharge 6 kv contact discharge ) 2 ) V/m ) 2 ) 4 kv ) 2 ) 2 kv (L-E) kv (L-L) ) 2 ) Technical information UL, 58, CSA C22.2 No. 4, NEMA (CD2-993 Standards Part 4, EN , EN ) NOTE: ) Performance criteria requires the DUT to experience no degradation or loss of performance Approvals CE, C-Tick, CSA, UL, Atex (pending) 2) Environment control circuit Rated insulation voltage - U [V] 69 AC Rated insulation strength - U imp [kv] 6 AC Rated operation voltage - U e [V] 69 AC (EC) / 69 AC (UL/CSA) e V [A] V [A] AC V [A] V [A] 24 V [A] DC-3 V [A] at L/R 5 ms 22 V [A] 44 V [A] Thermal current - the [A] Contact reliability Screw terminal cross section Terminal screw [kv] One conductor [mm 2 ] Flexible with wire Torque [Nm] end ferrule Two conductors [mm 2 ] Torque [Nm] One conductor [mm 2 ] Course stranded Torque [Nm] / solid Two conductors [mm 2 ] Torque [Nm] One conductor [mm 2 ] Stranded Torque [Nm] / solid Two conductors [mm 2 ] Torque [Nm] 3/2 ).5 /.5.75 /.75.6 /.6. /..4 /.4.2 /.2.8 / V, 5 ma M3 x ( ).55 2 x ( ).55 x (.5...4).55 2 x ( ).55 x ( ).55 2 x ( ).55 Pozidrive screwdriver size Slotted screwdriver size [mm].6 x 3.5 environmental ratings Ambient temperature Storage [ C] Operating [ C] Humidity Operating [%] , non-condensing Damp Heat per EC and EC Vibration (per EC ) [G] 3 Shock (per EC ) [G] 3 Maximum altitude [m] 2 Pollution environment Pollution degree 3 Degree of protection P 2 Type of relay Ambient compensated, time delay, phase loss standard Nature of relay Solid state Trip rating Trip class Reset mode Type ED Type EE Type ED Type EE 2 % FLA, 5, 2, 3 Manual Manual or automatic

15 AUSTRALA nhp.com.au SALES 3 NHP NHP Victoria Melbourne River Street Richmond VC 32 Tel Laverton 4-6 William Angliss Drive Laverton North VC 326 Tel Albury / Wodonga 847 Ramsden Drive Albury NSW 264 Tel Dandenong 4-42 Cyber Loop Dandenong South VC 375 Tel Tasmania Hobart 2/65 Albert Street Moonah TAS 79 Tel Launceston 3/3-7 Merino Street Kings Meadows TAS 7249 Tel New South Wales Sydney 3-34 Day Street North Silverwater NSW 228 Tel Newcastle 575 Maitland Road Mayfield West NSW 234 Tel Wollongong 34 ndustrial Road Unanderra NSW 2526 Tel ACT Canberra /87 Gladstone Street Fyshwick ACT 269 Tel Western Australia Perth 38 Belmont Ave Rivervale WA 63 Tel Northern Territory Darwin 3 Steele Street Winnellie NT 82 Tel Queensland Brisbane 6 Riverview Place Murarrie QLD 472 Tel Townsville 5 Leyland Street Garbutt QLD 484 Tel Rockhampton 4 Robison Street QLD 47 Tel Toowoomba Cnr Carroll Street and Struan Court QLD 435 Tel Cairns 2/ Bramp Close Portsmith QLD 487 Tel South Australia Adelaide Croydon Road Keswick SA 535 Tel NEW ZEALAND nhp-nz.com SALES 8 NHP NHP PO Box 62-9 Mount Wellington Auckland 64 New Zealand Auckland 8a Carbine Road Mt Wellington 6 Tel Hamilton 78 Rostrevor Street Hamilton 324 Tel Napier 26 Taradale Rd Onekawa 4 Tel New Plymouth 2 Dean Place Waiwhakaiho 432 Tel 8 NHP NHP Wellington 52 Victoria Street Lower Hutt 5 Tel Christchurch 85 Gasson Street Sydenham 823 Tel NHP Electrical Engineering Products Pty Ltd A.B.N NSPRECHEP7C Copyright NHP 2

CEP7-E Electronic motor protection relays

CEP7-E Electronic motor protection relays CEP7-E Electronic motor protection relays Motor protection with leading edge technology, expandable protection and communication. MOTOR CONTROL AND DRVES NHP Electrical Engineering Products AUS NZ 3 NHP

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

MOD6 RCBOs. New and retrofit solutions providing reliable personnel protection POWER DISTRIBUTION AND PROTECTION 1300 NHP NHP 0800 NHP NHP

MOD6 RCBOs. New and retrofit solutions providing reliable personnel protection POWER DISTRIBUTION AND PROTECTION 1300 NHP NHP 0800 NHP NHP MOD6 RCBOs New and retrofit solutions providing reliable personnel protection POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com

More information

Second Generation CEP7 Solid State Overload Relays

Second Generation CEP7 Solid State Overload Relays Second Generation Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of solid state overload relays advances Sprecher + Schuh s leading edge technology

More information

Motor Protection relays

Motor Protection relays Motor Protection relays Overload and Contactor selection chart - Motor protection/ overload types - 4 CT 8 thermal overload relay to suit CA8 contactors - 5 CT 7N thermal overload relays to suit CA 7 contactors

More information

CEP7 Solid State Overload Relays

CEP7 Solid State Overload Relays CEP7 Solid State Overload Relays Advanced solid state motor protection The introduction of the second generation of CEP7 solid state overload relays advances Sprecher + Schuh s leading edge technology

More information

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8 Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

Overload Relays. CEP7 Solid State Overload Relays... B2 Manual & Automatic Reset... B5 Larger Amp Manual & Automatic Reset... B7

Overload Relays. CEP7 Solid State Overload Relays... B2 Manual & Automatic Reset... B5 Larger Amp Manual & Automatic Reset... B7 Overload Relays Overload Relays CEP7 Solid State Overload Relays... 2 Manual & Automatic Reset... 5 Larger Amp Manual & Automatic Reset... 7 Accessories... 8 Technical Information... 12 Dimensions... 19

More information

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34

Overload Relays. Overload Relays. CEP9 Electronic Overload Relays... B27 Technical Information & Dimensions (Online)... B34 Overload Relays CEP7 Solid State Overload Relays... 2 Manual & Automatic Reset... 5 Larger Amp Manual & Automatic Reset... 7 Accessories... 8 Technical Information & Dimensions (Online)... 12 CEP9 Electronic

More information

Sinus Penta Variable Speed Drive

Sinus Penta Variable Speed Drive Sinus Penta Variable Speed Drive Advanced solutions for specialised applications motor control Sales 1300 NHP NHP Sales 0800 NHP NHP nhp.com.au nhp-nz.com SINUS PENTA VARIABLE SPEED DRIVE SPECIALISED SOLUTIONS

More information

onlinecomponents.com

onlinecomponents.com Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300

More information

Technical News. High Efficiency Motors & Type 2 Coordination Motor Starting. Industrial Electrical and Automation Products, Systems and Solutions

Technical News. High Efficiency Motors & Type 2 Coordination Motor Starting. Industrial Electrical and Automation Products, Systems and Solutions Issue #74 - Autumn 2016 Technical News Industrial Electrical and Automation Products, Systems and Solutions High Efficiency Motors & Type 2 Coordination Motor Starting Written by Steve Young, Application

More information

NHP MODdrive TM for Building Services

NHP MODdrive TM for Building Services NHP MOD TM for Building Services Energy efficient control for pumps and fans MOTOR CONTROL AND DRIVES NHP Electrical Engineering Products Pty Ltd AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com

More information

Series CA6 Contactors

Series CA6 Contactors Series CA6 Contactors The modern contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7

More information

Series CA7 Contactors

Series CA7 Contactors Series CA7 Contactors Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 75HP @ 46V Over years of design experience has produced Sprecher + Schuh s seventh generation

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Technical Information

Technical Information Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23

More information

PART D CATALOGUE. Sales 1300 NHP NHP nhp.com.au. AUTOMATION PRODUCTS PLCs. Fieldbus I/O Systems. Operator Panels & Touch Screens

PART D CATALOGUE. Sales 1300 NHP NHP nhp.com.au. AUTOMATION PRODUCTS PLCs. Fieldbus I/O Systems. Operator Panels & Touch Screens Industrial Electrical and Automation Products, Systems and Solutions PART D CATALOGUE D AUTOMATION PRODUCTS PLCs 01 Fieldbus I/O Systems Operator Panels & Touch Screens Visualisation & Reporting Software

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Accessories - Field Installable

Accessories - Field Installable Accessories - Field Installable A7 ontactors Type 1 General Purpose Enclosures ➋➌ Starters & Enclosed Products Enclosure (Box) Kit Includes: Hinged cover Backpan pre-drilled for listed arrangements (not

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Panel SCCR 50kA RMS Symmetrical 480V Maximum

Panel SCCR 50kA RMS Symmetrical 480V Maximum Panel SCCR 50kA RMS Symmetrical 480V Maximum 4 Short-Circuit Current Rating SCCR: The perspective or maximum symmetrical fault current at a nominal voltage to which an apparatus or system is able to be

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

PCS compact soft starters

PCS compact soft starters PCS compact soft starters Soft starting solutions with integrated motor protection. MOTOR CONTROL AND DRIVES Myriad Pro Condensed 12 pt Capitals White NHP Electrical Engineering Products AUS NZ 1300 NHP

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

PSE The efficient range Description

PSE The efficient range Description Description The PSE softstarter range is the world s first compact softstarters with Torque Control. This makes the PSE range an excellent choice for pumping application where water hammering normally

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Starters and assembled equipment

Starters and assembled equipment Starters and assembled equipment Starters Selection guide - 2 Direct-on-line motor starters Streamline CAT 7N DOL, less overload, enclosed three phase up to 11 kw - 4 Streamline CAT 7S DOL, less overload,

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Technical News. Drives: benefits, operation, pitfalls and harmonic solutions. Issue #59 - January 2011

Technical News. Drives: benefits, operation, pitfalls and harmonic solutions. Issue #59 - January 2011 Issue #59 - January 2011 Technical News INDUSTRIAL ELECTRICAL AND AUTOMATION PRODUCTS, SYSTEMS AND SOLUTIONS Drives: benefits, operation, pitfalls and harmonic solutions Written by Darren Besanko Product

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B Solid State Relays SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B AC semiconductor contactor Zero switching (RJ1A) or instant-on switching (RJ1B) Direct copper bonding (DCB) technology LED-indication

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

Designed for ease of integration with automation systems

Designed for ease of integration with automation systems BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

Product Description. Application Description

Product Description. Application Description -2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy Controllers AC Semiconductor Controller Type Soft starting and stopping of -phase induction squirrel cage motors Low inrush and reduced vibration during starting User-selected ramping profiles Integral

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents June 5 Vol. 2, Ref. No. [067] -1 Reduced Voltage Motor Starters Contents Description Page Solid-State Controllers Type S701, Soft Start.......................................... -2 Type TL, Torque Limiter........................................

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002 Overload Relays, Motor-Protective Relays Overview 06/00 Overload relays, motor-protective relays Page Technical overview 06/00 System overview 05/006 Overload relays, motor-protective relays 06/004 ZE,

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT amp ramp Operators Manual Saftronics S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD 6QT Tel: 0484 530893 Fax: 0484 550500 Website:www.saftronics.co.uk E-Mail: sales@saftronics.co.uk

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class:

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Series Motor Protection

Series Motor Protection 320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control CEP7 Solid-State Overload Relay for Motor Control Centers and Technical Data Description Page Product Description.............................................. 2 Specifications...................................................

More information

Three-Phase Soft Starters

Three-Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

CAT ENERGY STORAGE HYBRID MICROGRID SYSTEM

CAT ENERGY STORAGE HYBRID MICROGRID SYSTEM CAT ENERGY STORAGE HYBRID MICROGRID SYSTEM ENGINEERED BY CATERPILLAR. DELIVERED BY EPSA. DISCOVER THE POWER OF THE CAT HYBRID MICROGRID SYSTEM POWERING SUSTAINABLE PROGRESS. EVERYWHERE. ALL THE TIME. Caterpillar

More information

Olsys.

Olsys. Olsys www.thornlighting.com.au A unique versatile LED lantern covering a wide range of applications and installations in one minimalistic design 02 Olsys www.thornlighting.com.au Olsys offers 3 unique

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

OUTDOOR UNIT CONTROLLER (OUC)

OUTDOOR UNIT CONTROLLER (OUC) AUCKLAND temperzone Ltd 38 Tidal Road, Mangere, Auckland. Private Bag 93303, Otahuhu, N.Z. Phone 0-9-279 5250 Fax 0-9-275 5637 Email sales@temperzone.co.nz WELLINGTON Phone 0-4-569 3262 Fax 0-4-566 6249

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

Elmdene International Ltd

Elmdene International Ltd 1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

A21M. Introduction: Functional Overview: Key Protection & Control Functions: Introduction: ASHIDA has designed economical & reliable Multifunction A21M Protection & Control System. The simple and compact construction of A21 series, A21M relay provides integrated Protection, Control

More information

www.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self

More information