DIN rail type devices Technical data

Size: px
Start display at page:

Download "DIN rail type devices Technical data"

Transcription

1 DIN rail type devices Technical data Switch 63 A Building regulation/specification VDE 063 CEE Publ. 4, EN Rated voltage U n 50 V AC or 400/30 V AC Switching capacity ). x U n ;.5 x I n ; + pol.: cos = ohmic load; 3-pole: cos = 0.6 Service life according to VDE Frequenz Contact system Contact gap Hz with forced opening 3 mm Maximum ambient temperature C Shock protection VDE 006 Part 00 (VBG 4) Terminals Sealable Pillar terminals enclosed on all sides, loss-protected star / slotted screws in ON and OFF positions ) The maximum load is depented on the type of electrical equipment connected. Example: Maximum permissible I n = 6 A a) Filament lamps: maximum 8 pieces at 00 W each b) Fluorescent lamps non-compensated cos = 0.54 maximum 30 pieces at 40 W each oder maximum 8 pieces at 65 W each Fluorescent lamps compensated or DUO-wiring cos = 0.95 maximum 37 pieces at 40 W each oder maximum pieces at 65 W each Because of the low cold resistance, restrictions apply when switching for instance halogen lamps which are dependent on the type of the lamps, manufacturer, design, etc., (take into account manufacturer s details). The switching devices are alternating voltage devices. Modular devices For further details please refer to the technical appendix page T 3 T 3 On-off switch (load isolation switches see page 53) Number I n Width Cross- Type Item of poles [A] [x 7.5 mm] section number [mm ] NAS.6 / NAS NAS.6 SH NAS.5 SH NAS.3 SH NAS.6 SH NAS.5 SH NAS.3 SH NAS 3.6 SH NAS 3.5 SH NAS 3.3 SH NAS 4.6 SH NAS 4.5 SH NAS 4.3 SH Terminal cover., sealable for 3 and 4-pole NAS, set = pieces KAS SH NAS-C.40*) SH NAS-C.63*) SH NAS-C 3.40*) SH NAS-C 3.63*) SH Interlock facility to NAS-C BSP SH lockable NAS 363 E SH *) Dynamic short circuit withstand 0 ka at 00 A gl NAS-C

2 DIN rail type devices For further details please refer to the technical appendix page T 3 T 3 Number I n U lamp Width Type Item of poles A V AC [x 7.5 mm] number On-off switch with signal lamp 6 30 NAS-L.6 SH NAS-L.6 SH Change-over switch 6 NWS.6 SH NWS.6 SH NAS-L.6 Change-over switch with signal lamp 6 30 NWS-L.6 SH Ganged switch Imprint 6 NGS.6 SH I-O-II 6 NGS.6 S SH NGS 3.6 SH Connection cross-section 0 mm NWS.6 Louvre switch Imprint: 6 NJS.6 SH O- 6 NJS.6 SH Connection cross-section 0 mm Louvre switch Imprint: 6 NJT.6 SH O- 6 NJT.6 SH Push button without illumination NO+ NC 6 NT.6 SH NT.6 Illuminated push button without cup (with signal lamp E0, potential-free towards NOC) NO + NC 6 30 NT-L.6 SH NO + NC NT-L.6-0 SH NO + NC NT-L.6-4 SH Connection cross-section 0 mm Indicator light without cup (order separately) with glow lamp E 0, 30 V N-L SH with glow lamp E 0, 0 30 V N-L 0 SH with glow lamp E 0, 4 30 V N-L 4 SH without lamps (max. use Watt) N-L O SH Connection cross-section 0 mm NT-L.6 Cup to N-L and NT-L clear K-clear SH red K-red SH green K-green SH blue K-blue SH yellow K-yellow SH Filament lamps for N-L and NT-L (0 ma, 4 30 V) E0/4-30 V SH Glow lamps for N-L and NT-L (.5 ma, 30 V) E0/30 V SH (0.7 ma, 0-30 V) E0/0-30 V SH N-L with K-red Plate carriers ZST- SH for accommodating self-adhesive lettering plates (package unit = 50 pieces) Lettering plates ZBS-BLK SH for use in plate carriers ZST- and ZST-3 in perforated sheets DIN A5 of 60 pieces each (package unit = 0 sheets) 50

3 DIN rail type devices Load disconnecting switch according to IEC 947 Building regulations/specifications IEC 947, EN 60947, DIN VDE 0660 T 07 Design DIN rail installation, with and without locking facility Number of poles,, 3, 4, 3+N (3+N with leading N-contact) Rated operating current A Usage category AC A Max. rated switching capacity 300 A at cos ϕ = 0.65 Max. back-up fuse Rated switch current Short-circuit withstand 5 ka with 00 A gl back-up fuse Rated operating voltage 40 / 45 V AC Rated impulse voltage withstand 6 kv./50 µs Service life > switching cycles Protection class IP 40 (distributor installation) NAS.00 NAS 3.00 NAS-S.00 NAS-S 3.00 For further details please refer to the technical appendix page T 3 T 3 Number I n Width Type Item of poles [A] [x 7.5 mm] number Switch without locking facility 40 NAS.40 SH NAS.63 SH NAS.80 SH NAS.00 SH NAS.40 SH NAS.63 SH NAS.80 SH NAS.00 SH NAS 3.40 SH NAS 3.63 SH NAS 3.80 SH NAS 3.00 SH NAS 4.40 SH NAS 4.63 SH NAS 4.80 SH NAS 4.00 SH N 40 4 NAS 3N.40 SH N 63 4 NAS 3N.63 SH N 80 4 NAS 3N.80 SH N 00 4 NAS 3N.00 SH Number I n Width Type Item of poles [A] [x 7.5 mm] number Switch with locking facility, lockable with padlock in on and off positions (maximum shackle diameter 4 mm) 40 NAS-S.40 SH NAS-S.63 SH NAS-S.80 SH NAS-S.00 SH NAS-S.40 SH NAS-S.63 SH NAS-S.80 SH NAS-S.00 SH NAS-S 3.40 SH NAS-S 3.63 SH NAS-S 3.80 SH NAS-S 3.00 SH NAS-S 4.40 SH NAS-S 4.63 SH NAS-S 4.80 SH NAS-S 4.00 SH N 40 4 NAS-S 3N.40 SH N 63 4 NAS-S 3N.63 SH N 80 4 NAS-S 3N.80 SH N 00 4 NAS-S 3N.00 SH Modular devices

4 DIN rail type devices For further details please refer to the technical appendix page T 33 Number of poles I n Width Type Item [A] [x 7.5 mm] number Sockets for mounting on DIN rails +E -pole + earth contact VDE 6.5 NST SH pole without earth contact 6.5 PC 6/ 3. SH VDE +E -pole + central earth contact 6.5 PC 6/. SH (French design) +E sockets for mounting on DIN rail 6.5 PC 6/ SH pole + earth contact jack (Danish design) NST Volt and ammeter according to DIN Moving iron measuring instrument Quadrant scale, 43 mm scale length Shock-proof connection terminals according to VBG 4 Frequency range: Hz Class.5 (=.5% accuracy based on scale end value) Test voltage kv Measuring instruments can be permanently subjected to. times overload Measuring range Internal Width Type Item V or A consumption [x 7.5 mm] number VA NV 500 Voltmeter NV 5 SH NV 00 SH NV 50 SH NV 500 SH Ammeter for direct connection with double overload scale N5 SH N5 SH Ammeter for connection to transformer 5 A sec N00/5 SH NA 300/5 SH Voltmeter change-over switch or linked voltages + 3 external conductors to N, with zero positions U e max. 660 V, I n max. 6 A 3 NVU SH

5 DIN rail type devices Bells, buzzers Technical data: For mounting on DIN rail 35 mm According to NFC 6730 Max. switch-on time: min. Volume at m distance: 8 db A Long-term signalling possible via external flashing relay (impulse/interval ratio : ) IP 30 For further details please refer to the technical appendix page T 33 Designation Coil- Width Power Current Type Item Voltage number V AC [x 7.5 mm] [VA] [ma] Bells for mounting SO SH on DIN rail SO 30 SH Buzzers for RO SH mounting RO 30 SH on DIN rail Modular devices SO 53

6 Surge arresters For basic protection of low-voltage consumer systems, built on the basis of IEC 99. Maximum protection through high-performance zinc oxide varistor with non-linearity exponent > 30 Modules easily changed without mains voltage interruption (important for instance with EDP systems and insulation measurements) Requirement class C Earth-wiring of the multi-pole devices already carried out at the factory Remote signal module for subsequent installation with potential-free change-over switch, slides into basic lower part to report a defective status High discharge capacity with low protection level and short switch-off time Operating principle of the 3+ circuit of NSA 4TT When used in 5-conductor networks (TT) electrical isolation is required according to the draft standard DIN VDE 000 part 543/A, which is not guaranteed when installing varistors ahead of the residual current-operated relay! With the 3+ circuit of our new NSA 4TT, the discharge of the three phases is accomplished with varistors to N and via an aggregate current gas arrester (gas spark gap = electric isolation) from N to PE. Consequently this surge arrester can also be installed ahead of the residual current-operated relay (no residual current release during discharge impulses). Rated voltage U N 30 V Operating voltage U ~ max. 75 V Operating voltage U = max. 350 V Rated discharge surge current I SN (8/0) 5 ka Rated discharge limit current I GR (8/0) 40 ka Back-up fuse max. 00 A gl Housing polycarbonate grey (RAL 7035) Protection level U R (bei I SN ).3 kv Response time t a 5 ns Connection cross-section 4 5 mm Ambient temperature 0 60 C Protection class IP 0 Tripping current 30 s I ÜA 0. A Installation on inverted cup rail 35 mm For further details please refer to the technical appendix page T 34 Number Width Type Item of poles [x 7.5 mm] number Surge arrester NS SH NS SH NSA 3 SH NSA 4TT SH Replacement module with varistor (L N) ( plug-type) NSA SH NSA 3 Replacement module with gas spark gap (N PE) ( plug-type) NSA TT SH Remote signal module change-over switch A / 50 V AC NSA-FS SH NSA TT 54

7 Mains disconnector NAK with VDE certification VDE certification as per EN and EN Self-regulating switching threshold for simple commissioning Automatic detection and safe switching, without complicated installation of base-load elements, also for: electronically controlled consumers (vacuum cleaners, etc.) light controlled by rotary dimmers fluorescent and energy saving lamps, halogen lamps at electronic transformers, etc. Monitoring voltage for disconnected consumers: 30 V DC to 8 ma this permits operation of glow lamps in illuminated push buttons, switches with control lamps, so-called baby night-lights, etc. specially included system control lamps for the power socket, for checking functions voltage control with VDE-tested voltmeters (Duspol etc.) possible with monitoring DC voltage of 30V, thus indicating that the corresponding system part is connected to the mains reliably minimum contact load of e.g. switches, etc. Simple installation thanks to innovative circuit concept with no need for adjusting switch-on and switch-off thresholds All mains disconnectors with mains control LED and alarm on incorrect connection (protected from reverse poling); NAK 7 also with button to bridge device fault and LED displays for residual current (brightness control) and for cutoff ("disconnected") Reliable switching and non-ageing even in critical installation situations. Modular devices Technical data: Nominal voltage: 30 V AC Switching contact: NC contact (µ) Nominal current: 6 A Max. switching capacity: 3500 VA cos = 0.5 Lamp load: max. 300 W Cutoff: single pole Monitoring voltage: 30 V DC (max. 8 ma) Residual ripple (typical): < 6 mv Service life: mechanical x 0 7 switching cycles under nominal load: 0 5 switching cycles Max. ambient temperature: 0 45 C Mains disconnector with mains control LED For further details please refer to the technical appendix page T 34 Width Type Item [x 7.5 mm] number NAK 5 SH Mains disconnector with 3 LEDs for mains control, for residual current and to show "disconnected", also with button to bridge device fault NAK 7 SH System control lamp for use in sockets NAK-L SH for function monitoring (included in scope of supply of NAK 5 and NAK 7) NAK 7 55

8 Impulse switch Technical data: Switching capacity 6 A / 50 V AC Contact distance > 3 mm Switching position display Manual control button Additional coil voltages and contact equipment on request Frequency: 50 Hz Shock protection according to VDE 006 T 00 (BGV A, before VGB 4) Types NFS and NFZ : Approved by the Lloyd s Register of Shipping Coil Width I n Type Item voltage [x 7.5 mm] [A] number Impulse switch 8 V AC 6 NFS 00.8 SH with normally V AC 6 NFS 00. SH open contact 4 V AC 6 NFS 00.4 SH V AC 6 NFS 00.4 SH V AC 6 NFS SH V AC 6 NFS 00.0 SH V AC 6 NFS SH NFS with change-over 8 V AC 6 NFS 00.8 SH contact V AC 6 NFS 00. SH V AC 6 NFS 00.4 SH V AC 6 NFS 00.0 SH V AC 6 NFS SH V/60 Hz 6 NFS SH V DC 6 NFS 00. DC SH V DC 6 NFS 00.4 DC SH with normally open 8 V AC 6 NFS SH 99 7 contact and normally V AC 6 NFS 0..6 SH 99 7 closed 4 V AC 6 NFS SH contact 30 V AC 6 NFS SH with normally open 8 V AC 6 NFS SH contacts V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH NFS with change-over 8 V AC 6 NFS SH contacts V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC/60 Hz 6 NFS SH V DC 6 NFS SH V DC 6 NFS SH with 3 normally open 30 V AC 6 NFS SH contacts

9 Impulse switches, Impulse switches with central control Coil Width In Type Item voltage [x 7.5 mm] [A] number Impulse switch with 3 change-over contacts 30 V AC 6 NFS SH NFS with 4 normally open contacts 8 V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH with 4 change-over contacts 8 V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V AC 6 NFS SH V DC 6 NFS SH Impulse switches with central control with normally open contact 4 V AC 6 NFZ SH V AC 6 NFZ SH Z A 4 Z E Modular devices with change-over contact 4 V AC 6 NFZ SH V AC 6 NFZ SH Z A 4 4 V DC 6 NFZ SH Z E + with normally open contacts 4 V AC 6 NFZ SH Z A V AC 6 NFZ SH Z E 4 V DC 6 NFZ SH NFZ with 3 normally open contacts 4 V AC 6 NFZ SH Z V AC 6 NFZ SH Z E 4 V DC 6 NFZ SH with 3 normally open contacts + change-over contact 30 V AC 3 6 NFZ SH Z A Z E with 3 change-over contacts 30 V AC 3 6 NFZ SH 99 5 Z Z E with 4 change-over contacts 30 V AC 3 6 NFZ SH NFZ

10 Low-noise impulse switches Low-noise impulse switches Very low switching noise Low dissipation Identical contact assignment as with the mechanical remote switches µ-contact Jack teminals with wire protection and no-loss star/slotted screws Shock protection according to VDE 006 T 00 (BGV A, before VBG 4). Coil Width In Type Item voltage [x 7.5 mm] (A) number with normally 8 V UC 0 NFS-G 00.8 SH 99 open contact V UC 0 NFS-G 00. SH 99 4 V UC 0 NFS-G 00.4 SH V AC 0 NFS-G SH 99 8 NFS-G 00.4 NFS-G 00.30: glow-lamp resistant up to 30 glow lamps of ma each 58

11 Flush-mounting impulse switches Coil In Type Item voltage (A) number Impulse switch with normally 8 V AC 0 IFS- s/8~ SH 99 4 open contact V AC 0 IFS- s/~ SH V AC 0 IFS- s/4~ SH V AC 0 IFS- s/0~ SH 99 7 IFS-s IF-SB /IF-AK Accessories: Quick attachment for mounting of IFS-s and IFR-s on standard rail IF-SB SH Capfor IFS-s and IFR-s IF-AK SH Impulse switch with normally 8 V AC 0 IFS- s/8~ SH open contacts V AC 0 IFS- s/~ SH V AC 0 IFS- s/4~ SH V AC 0 IFS- s/0~ SH Modular devices with change-over 8 V AC 0 IFS- w/8~ SH contact V AC 0 IFS- w/~ SH V AC 0 IFS- w/4~ SH V AC 0 IFS- w/4~ SH V AC 0 IFS- w/48~ SH V AC 0 IFS- w/0~ SH with change-over 8 V AC 0 IFS- w/8~ SH 99 contacts V AC 0 IFS- w/~ SH 99 4 V AC 0 IFS- w/4~ SH V AC 0 IFS- w/4~ SH V AC 0 IFS- w/48~ SH V AC 0 IFS- w/0~ SH 99 6 V DC 0 IFS- w/= SH V DC 0 IFS- w/4= SH with normally 4 V DC 0 IFS- s/4= SH open contact IFS w/ 59

12 Relays Coil Width In Type Item voltage [x 7.5 mm] (A) number Relay with reduced 4 V AC 6 NFRV SH dissipation for tight 30 V AC 6 NFRV SH series embodiment with change-over contact 4 NFRV Relay with normally 8 V AC 6 NFR 00.8 SH 99 3 open contact V AC 6 NFR 00. SH V AC 6 NFR 00.4 SH V AC 6 NFR SH NFR with change-over 8 V AC 6 NFR 00.8 SH 99 0 contact V AC 6 NFR 00. SH V AC 6 NFR 00.4 SH V AC 6 NFR 00.4 SH V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR 00.0 SH V AC 6 NFR SH V/60 Hz 6 NFR SH V DC 6 NFR 00. DC SH V DC 6 NFR 00.4 DC SH V DC 6 NFR DC SH Relay with normally open contact and normally 8 V AC 6 NFR SH 99 6 closed contact V AC 6 NFR 0..6 SH V AC 6 NFR SH V AC 6 NFR SH NFR with normally 30 V AC 6 NFR SH open contacts 4 NFR Relais with change-over 8 V AC 6 NFR SH 99 5 contacts V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V AC/60 Hz 6 NFR SH V DC 6 NFR SH V DC 6 NFR SH V DC 6 NFR SH V DC 6 NFR SH NKA-R Terminal cover NKA-R SH for full covering of multi-pole impulse switches and relays; sealable (up to width = TE) 60

13 Relays Coil Width In Type Item voltage [x 7.5 mm] (A) number Relay with 3 normally 30 V AC 6 NFR SH open contacts 4 6 with 3 change-over 30 V AC 6 NFR SH 99 9 contacts with 3 normally open contacts and change-over contact 30 V AC 6 NFR SH 99 8 Modular devices with 4 normally 8 V AC 6 NFR SH 99 3 open contacts V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH NFR with 4 chance-over 8 V AC 6 NFR SH 99 5 contacts V AC 6 NFR SH V AC 6 NFR SH V AC 6 NFR SH V DC 6 NFR SH V DC 6 NFR SH

14 Boiler relay / sealable terminal cover / fault signal relay / low-noise relays Coil Width In Type Item voltage [x 7.5 mm] (A) number Boiler relay 30 V AC 6 NSR SH with change-over For use in EVU field, e.g. to control storage heating contact systems. With indication of switching status and full sealable terminal cover. 4 NSR Fault signal relay 4 V UC 0 NRG 4 SH 99 4 The fault signal relay NRG 4 accomplishes voltage control with fault signal. The built-in sliding switch simulates the voltage failure if actuated. As soon as the controlled voltage fails, the output change-over contacts (30 V AC) change over. Signalling (e.g. with a horn) or switching off of the endangered plant component can be effected in this way. Coil current (4 V) = 0 ma NRG 4 Low-noise relays Very low switching noise Low dissipation for close series installation Identical contact assignment as with the mechanical remote switches Pillar terminals with wire guard and no-loss star/slotted screws Shockproof according to VDE 006 T 00 (BGV A, before VBG 4) µ-contacts Coil Width In Type Item voltage [x 7.5 mm] (A) number Relay 8 V UC 6 NFR-G 00.8 SH 99 6 with change-over V UC 6 NFR-G 00. SH 99 6 contact 4 V UC 6 NFR-G 00.4 SH V AC 6 NFR-G SH NFR-G with change-over 8 V UC 8 NFR-G 00.8 SH 99 7 contacts V UC 8 NFR-G 00. SH V UC 8 NFR-G 00.4 SH V AC 8 NFR-G SH NFR-G 00. 6

15 Flush-mounting relays Coil In Type Item voltage (A) number Relay with normally 8 V AC 0 IFR- s/8~ SH open contact V AC 0 IFR- s/~ SH 99 4 V AC 0 IFR- s/4~ SH V AC 0 IFR- s/0~ SH IFR-s/ IFR s/ Accessories (quick attachment and protection cap) see page 59 Relay with normally 8 V AC IFR- s/8~ SH open contacts 4 V AC IFR- s/4~ SH V AC IFR- s/0~ SH Relay with change-over 8 V AC IFR- w/8~ SH 99 8 contact V AC IFR- w/~ SH V AC IFR- w/4~ SH V AC IFR- w/4~ SH V AC IFR- w/0~ SH Modular devices Relay with change-over 8 V AC IFR- w/8~ SH 99 9 contacts V AC IFR- w/~ SH V AC IFR- w/4~ SH V AC IFR- w/4~ SH V AC IFR- w/48~ SH V AC IFR- w/0~ SH V DC IFR- w/= SH V DC IFR- w/4= SH

16 Contactors 0 A Technical data: Shockproof according to VDE 006 T00 (BGV A, before VBG 4) Contact gap > 3 mm Indication of switching status Contactors Coil I n Contacts *) Width Type Item voltage [x 7.5 mm] number [V] [A] NO NC CO 30 AC 0 CT SH CT AC 0 CT SH AC 0 CT SH AC 0 CT SH AC 0 CT SH AC 0 CT SH AC 0 3 CT SH AC 0 3 CT SH DC 0 3 CT SH AC 0 4 CT SH AC 0 4 CT SH DC 0 4 CT SH CT AC 0 CT SH AC 0 3 CT SH AC 0 4 CT SH * NC = normally closed contact; NO = normally open contact; CO = change-over contact 64

17 Contactors 3 A Coil I n Contacts *) Width Type Item voltage [x 7.5 mm] number [V] [A] NO NC CO Contactors 30 AC 3 CT SH CT AC 3 CT SH AC 3 CT SH Modular devices 4 30 AC 3 CT SH AC 3 3 CT SH AC 3 4 CT SH AC 3 CT SH AC 3 3 CT SH AC 3 4 CT SH * NC = normally closed contact; NO = normally open contact; CO = change-over contact 65

18 Contactors Coil I n Contacts *) Width Type Item voltage [x 7.5 mm] number [V] [A] NO NC CO Contactors direkt current magnetic drive Auxiliary switches can be attached DC 4 CT 4- SH AC CT DC 4 3 CT 4-30 SH AC DC 4 3 CT 4-3 SH AC 4 DC 4 4 CT 4-40/4 SH AC DC 4 4 CT 4-40 SH AC DC 4 4 CT 4-04 SH AC 30 DC 40 3 CT 40-0 SH AC CT DC CT SH AC 30 DC CT SH AC 40 DC CT 40-40/40 SH AC 30 DC 63 3 CT 63-0 SH AC 30 DC CT SH AC 30 DC CT SH AC 40 DC CT 63-40/40 SH AC CT * NC = normally closed contact; NO = normally open contact; CO = change-over contact 66

19 Day/night contactors Technical data: Shockproof according to VDE 006 T00 (BGV A, before VBG 4) Contact gap > 3 mm Indication of switching status 3 mechanically lockable switch positions: A = contactor function I = manual switching on with automatic resetting to A during the next activation impulse 0 = mechanical switching off Day/night contactors 0 A I 4 3 Coil I n Contacts *) Width Type Item voltage [x 7.5 mm] number [V] [A] NO NC CO 30 AC 0 CT-JN SH Modular devices CT JN A I AC 0 3 CT-JN SH A I AC 0 4 CT-JN SH A I 3 30 AC 3 CT-JN SH A I AC 3 3 CT-JN SH A I AC 3 4 CT-JN SH * NC = normally closed contact; NO = normally open contact; CO = change-over contact 67

20 Day/night contactors, accessories Day/nightcontactors Direct current magnetic drive U b Auxiliary switch attachable Coil I n Contacts *) Width Type Item voltage [x 7.5 mm] number [V] [A] NO NC CO DC 4 3 CT-JN 4-30 SH AC CT JN DC 4 4 CT-JN 4-40 SH AC 30 DC 40 3 CT-JN 40-0 SH AC CT 4-30 with DS 30 DC CT-JN SH AC 30 DC CT-JN SH AC Auxiliary switch for CT 4, 40, 63 and CT-JN 4, 40, HS 0 SH HS SH 99 NKA-S 4 DS Terminal cover for ceiling for CT 4- NKA-S 4 SH 99 7 for CT 40- NKA-S 40 SH 99 8 Distance module 0.5 DS SH 99 4 Spacer to accommodate lettering plates selfadhesive (package unit = 50 pieces) ZST- SH Lettering plates For use in plate carriers ZST- and ZST-3 in perforated sheets DIN A5 of 60 pieces each (package unit = 0 sheets) ZST-BLK SH HS 0 * NC = normally closed contact; NO = normally open contact; CO = change-over contact 68

21 Load disconnecting relay Connection example for a load disconnecting relay NLRE Continuous flow heater Night storage heater A load disconnecting relay (also called shedder, divider, or priority switch) is installed when several large electric users (i.e. continuous flow heater and night storage heater) have to be operated. This relay isolates the long-term operating consumers (night storage heater) from the mains when the short-term operating device (continuous flow heater) is switched on. NLRE Control voltage Electromechanical load disconnecting relay normally closed contact (NC) A / 50 V AC Sealable terminal cover For attachment to DIN rail 35 mm and wall mounting Connectable load cross-section: Control contact mm Coil contact.5 6 mm A continuous increase of the current to the actuation value is not permitted with electromechanical load disconnecting relays! Modular devices For further details please refer to the technical appendix page T 4 + T 43 For continuous I pull-on I n Width Type Item flow meter [A~] [A~] [x 7.5 mm] number Load disconnecting relay electromechanical NLRE 3 9 SH kw ) NLRE 6 39 SH kw NLRP 6 39 SH ) Because of its drop-back delay of two mains half-waves this relay is also suitable for use with the new generation of controlled continuous flow heaters. NLRE

22 Blind control Coupling/disconnecting relays, blind control relays The control of blinds, roller blinds, roof windows becomes more and more important. The majority of the drives for blinds, etc., are single-phase capacitive-starting motors. If these drives are connected in parallel, they will fluctuate in the vicinity of the upper or lower limit switches. The reason for this is that the motor whose limit switch has already switched off is fed with a return current by the capacitor of the motor still operational so that it runs in the opposite direction. This faulty operation can damage the limit switches resulting in drive or sun protection failure. For this reason it is not permitted to connect single-phase, capacitive-starting motors in parallel. The devices listed in the following permit trouble-free control of several drives at the same time or with several control signals from the distribution. NFR-K.30 Coupling/disconnecting relay For mounting on DIN rail according to DIN EN 500 For activating several single-phase, capacitive-starting motors. Decoupling is necessary since it is not permitted to connect these motors in parallel (risk of destruction; note motor manufacturer s instructions) Connection per coupling relay dives Additional operation per drive possible through local push button or switch Indication of switching status of the cental signal Manual operation on the device Central UP and central DOWN Ambient temperature 5 C 40 C Contact 6 A / 50 V AC Coil 30 V AC Central UP has priority over central DOWN For further details please refer to the technical appendix page T 44 lauferhitzer Für Durch- I Anzug I n Width Type Item [A~] [A~] [x 7.5 mm] number NFR-K.30 SH

23 Bell transformers According to IEC 74/EN 6074 and VDE 055 Design ) U prim. U sek. U 0 I n Width Type Item [V AC] [V AC] [V AC] [A] [x 7.5 mm] number For further details please refer to the technical appendix page T 45 Not unlimited short-circuit proof transformers NTF 0.5 SH Switch-off type NTF-S 0.5 SH NTF SH Switch-off type NTF-S SH V NTF.0. SH Switch-off type V NTF-S.0. SH NTF-S 0.5 Terminal cover set = pieces NKT-F SH Conditionally short-circuit proof transformers Switch-off type, NTR 00 SH with thermal over NTR 0 SH load protection NTR 0 SH without VDE symbol, e.g. as power supply for RC sensor Switch-off type, V : NTR 03 SH with thermal over- 5 V : load protection 8 V : Terminal cover set = pieces NKT SH Modular devices Power supply 30 4 ) 4 NLN-4.4 SH Residual waviness 5.5 V with full load Short-circuit protection: T L 50 V NLN-4.4 ) U 0 = no-load voltage ) Pulsating DC voltage 7

24 Safety shaver sockets according to IEC 74/EN Technical data For Hz Continuous power output 0 VA With automatic operating switch Intended for complete installation with UP/AP box Isolating transformer for electrical separation Overload disconnection through overcurrent relay For further details please refer to the technical appendix page T 46 Design U prim. U sek. Power RAL Type Item number [V AC] [V AC] [VA] GRT 4 According to EN 6074 Flush mounting, white, including flush-mounting box and flush protective cover GRT 4 (Pure white) SH GRT 4 (Pearl white) SH GRT 4/5-5 SH Surface GRT 4 Aw SH mounting, white GRT 4 Aw 5/5 SH Flush mounting U sec change-over type, white, including flush mounting box and flush protective GRTU 4 SH Surface mounting U sec change-over type, white GRTU 4 Aw SH Accesories GRT 4 / GRTU 4 Flush-mounting box with flush protective cover UPS 4 SH Cover seal DR SH Surface mounting box, white APS 4 SH Flush-mounting box with nail attachment clause (for prefabricated building) UPF 4 SH UPS 4 Overcurrent relay Automatic operating switch Isolating transformer Socket Schematic representation of a shaver socket Function and construction: Transformer, overcurrent relay, universal socket with automatic operating switch and cover plate are integrated in the safety shaver socket as an installation unit (shaver socket insert). This installation unit can be combined with a moulded plastic flush-mounting box or a moulded plastic surfacemounting box depending on installation possibilities; connection cross sections up to x.5 mm. The socket is designed so that shavers with European and British round pin and American flat pin plugs can be connected. It is also equipped with an automatic operating switch which connects the isolating transformer primary side to the mains system only after plugging in, in this way avoiding no-load losses. For surface mounting installation in very moist atmosphere with the possibility of condensate formation within the shaver socket, an opening in the back wall provided for this purpose can be pierced to drain the condensate. 7

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical) MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Training & Didactic Systems. Fundamentals of Electrical Engineering

Training & Didactic Systems. Fundamentals of Electrical Engineering Training & Didactic Systems Fundamentals of Electrical Engineering Catalog WA1E/01 Table of Contents Page Our Service, Our Customers and fields of technology 2 Introduction 4 Instruction modules measuring

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

BETA Switching Switching Devices

BETA Switching Switching Devices Siemens AG 200 BETA Switching /2 Product overview /3 5TT4 1 remote control switches /11 5TT4 2 switching relays /14 5TT5 7 Insta contactors, DC technology /20 5TT5 Insta contactors, AC technology /2 5TT3

More information

Installation Contactors RIC, RAC

Installation Contactors RIC, RAC Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

Command and signalling E 250, E 259 selection table

Command and signalling E 250, E 259 selection table E 250, E 259 selection table Latching relays E250 Installation relays E259 Contacts switching on each impulse sent to the control coil. Contacts maintained in switched position only while the control coil

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED Art. no.: 1711DE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Modular Contactors and Switches D681E121

Modular Contactors and Switches D681E121 Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE ( ka) The device is a combination of residual current circuit breaker and circuit breaker For

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

EAD10H80D EAD14H80D EAD17H80D

EAD10H80D EAD14H80D EAD17H80D 12.4 Technical data Consumer units and enclosures dimensions and data RCCB controlled surface mounting consumer units Eaton list Dimensions (mm) number w h d EAD2/3M63 154 223 101 EAD2/3M80 EAD4M63 235

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) With central control inputs, front button and various operating modes and functions General purpose, user-friendly electronic pushbutton dimmer for

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components DRA automatic stairway lighting Order-No. : 0821 00 Impulse insert Order-No. : 0336 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Electronic Circuit Breaker ESS20

Electronic Circuit Breaker ESS20 Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

BETA Fuses and Fuse Systems

BETA Fuses and Fuse Systems Introduction Overview Application LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in the switchboards of power supply companies. Fuses

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information