Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.
|
|
- Barrie Walker
- 5 years ago
- Views:
Transcription
1
2 Elki Cable is one of Turkey's leading companies in its sector and produces cables in accordance with international quality standards. Elki Cable has been founded in 983 and since 986, it has been producing cables under "IRMAK KABLO" brand name. The company has satisfied customers over the years by focusing on quality and timeliness of delivery. Various cables used in appliances, consumer electronics products, PC's, and energy transmission are produced in accordance with the ISO 900:000 quality system. All ranges of cables have TSE (Institute of Turkish Standards) and HAR certificates, enabling us to export 30% of our production to the following countries: The Netherlands, the United Kingdom, Germany, Austria, Bulgaria, Romania, Ukraine, Georgia, Iraq, Lebanon, Guinea. Elki has 00 squaremeters covered production space in Istanbul and Manisa with 0 employees. PVC used in cables is also produced in house, while copper is supplied from local vendors. Our annual production capacity is 3000 tons for copper and 4000 tons for PVC. Beside the cables represented in this catalogue, we are also ready to meet any of your special requirements.
3 Rigid single core cables for internal wiring H05V-U Nominal Ave. Outer Max. resistance cross-section min. max. at 0 C 0,9,3 36, ,,5 4,5,3,,7 8, 5 Nominal Ave. Outer Max. resistance cross-section min. max. at 0 C,5,38,6 3,,0 9,5,78 3, 3,4 7,4 30 4,6 3,6 4,4 4,6 47 6,76 3,8 5,0 3,08 68 H07V-U Product Description Applications - Solid or stranded copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-U: 300V / 500V H07V-U: 450V / 750V - Fixed protected installation inside appliances and in or on lighting fittings. -Suitable for installation in mounted or embedded conduits, only for signalling or control circuits.
4 Flexible single core cables for internal wiring H05V-K Cross Section No. & Outer Max. resistance min. max. at 0 C 6x0.9,,5 39, x0.9,,7 6,0 3x0.9,4,8 9,5 5 Max. resistance H07V-K Cross Section No. & Outer min. max. at 0 C,5 7x0.5,8 3,4 3,30 0,5 45x0.5 3,4 4, 7, x0.9 3,9 4,8 4, x0.9 4,4 5,3 3, x0.39,0 5,7 6,8, x0.39,0 6,7 8,, x0.39, 8,4 0, x0.39, 9,7, x0.39,4,5 3, x0.39,4 3, 6, x0.39,6 5, 8, Product Description Applications - Flexible copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-K: 300V / 500V H07V-K: 450V / 750V - For internal wiring in electrical equipment where small bending radius is required.
5 Flexible multi-core cables H03VV-F Cross Section No. & Max. resistance Jacket Outer min. max. at 0 C x0.50 6x0.9 4,6 5, x0.75 4x0.9 4,9 6, G0.50 6x0.9 4,9 6, G0.75 4x0.9 5, 6, G0.50 6x0.9 5,4 6, G0.75 4x0.9 5,7 7,3 6 Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - Cores twisted together - PVC jacketed cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 300V - Suitable for light moveable equipment, in houses and offices (wiring for light portable appliances, which are subject to slight mechanical stress) - Also suitable where good flexibility is required, provided there is no risk of mechanical damage. - For connectionof household appliances, radio and TV sets and electrical devices to power supply networks with rated voltage U0/U 300/300V
6 Flexible multi-core cables H05VV-F Cross Section No. & Max. resistance Jacket Outer min. max. at 0 C x0.75 4x0.9 5,7 7, 6 53 x.00 3x0.9 5,9 7,5 9,5 69 x.50 7x0.5 6,8 8,6 3,3 83 x.50 45x0.5,0 8, x x0.9, 9,7, G0.75 4x0.9 6,0 7, G.00 3x0.9 6,3 8,0 9,5 86 3G.50 7x0.5 7,4 9,4 3,3 07 3G.50 45x0.5, 9,, G x0.9, 3, G0.75 4x0.9 6,6 8, G.00 3x0.9 7, 9, G.50 7x0.5,0 8, G.50 45x0.5, 0,, G x0.9,,5 4, G0.75 4x0.9 7,4 9, G.00 3x0.9 7,8 9, G.50 7x0.5, 9,3, G.50 45x0.5,, 3, G x0.9,4 3,0 6, Product Description Applications - Flexible copper conductor - Color-coded PVC insulation - Cores twisted together - For connectionof household and office appliances, electrical tools and devices to power supply networks with rated voltage U0/U 300/500V - PVC jacketed cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - For domestic appliances in damp conditions (washing machines, hairdryers, refrigerators, etc) - Permitted for domestic heating appliances provided they do not come into contact with sources of heat or radiation
7 Flat-shaped flexible multi-core cables H03VVH-F Cross Section No. & Max. resistance Jacket Outer min. max. at 0 C x0.50 6x x x x0.75 4x0.9 3.x5. 3.8x Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord - Rated Temperature: 70 C - Rated Voltage: 300V / 300V -Suitable for light moveable equipment, in houses and offices (wiring for light portable appliances which are subject to slight mechanical stress) - Also suitable where good flexibility is required, provided there is no risk of mechanical damage. - For connection of household appliances, radio and TV sets and electrical devices to the power supply networks with rated voltage U0/U 300/300V H05VVH-F Cross Section No. & Jacket Outer Max. resistance min. max. at 0 C x0.75 4x x x x.00 3x x6. 4.7x7.5 9,5 45 Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord, flat type - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - In household and office appliances which are subject to medium mechanical stress. - For domestic appliances in damp conditions (washing machines, hairdryers, refrigerators, etc) - Permitted for domectic heating appliances provided they do not come into contact with sources of heat or radiation.
8 Single-core non-sheathed cables for internal wiring H05V-K Cross Section No. & Max. resistance min. Outer max. at 0 C 6x0.9,, x0.9,,7 6,5 3x0.9,4,8 9,5 4, TS HD.7 S H07V-K Cross Section No. & Max. resistance min. Outer max. at 0 C,5 7x0.5,8 3,4 3,30 9,5 45x0.5 3,4 4, 7, x0.9 3,9 4,8 4, x0.9 4,4 5,3 3, x0.39,0 5,7 6,8, x0.39,0 6,7 8,, x0.39, 8,4 0, x0.39, 9,7, TS HD.7 S Product Description Applications - Bare stranded copper conductor - Color-coded PVC insulation - Rated Temperature: 90 C - Rated Voltage: H05V-K: 300V / 500V H07V-K: 450V / 750V - Suitable for internal wiring and insallation inside appliances and lighting fittings.
9 Single-core non-sheathed cables for general purposes H05V-R Cross Section No. & Max. resistance min. Outer max. at 0 C 7x0.30,, x0.37,,7 4,5 7x0.43,4,8 8, 5 H07V-R Cross Section No. & Max. resistance min. Outer max. at 0 C,5 7x0.5,8 3,4,0,5 7x0.66 3,4 4, 7, x0.83 3,9 4,8 4, x.0 4,4 5,3 3, x.34,0 5,7 6, x.70,0 6,7 8,,5 5 7x.0, 8,4 0, x.55, 9,7,7 4 3 Product Description Applications - Seven wire, bare copper conductor - Color-coded PVC insulation - Rated Temperature: 70 C - Rated Voltage: H05V-R: 300V / 500V H07V-R: 450V / 750V - Suitable for fixed protected installation inside appliances and in lighting fittings.
10 FLRY-A Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper (Type A) : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 7 x 0,6 0 54,40 0,0,40 4,5 9 x,0 37,0 0,8 0,,70 6,6 5 9 x 0,3,30 4,70 0,30 0,4, x 0,6,50 8,50 0,30 0,4,0,5 9 x 0,3 0,70 0,30 0,4, x 0,37,00 9,4 0,35 0,8,,5 9 x 0,4,0 7,60 0,35 0,8 3,00 6
11 FLRY-B Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper (Type B) : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 x 0, 0 54,40 0,0,40 4,5 6 x 0,,0 37,0 0,8 0,,70 6,6 5 4 x 0,,30 4,70 0,30 0,4, x 0,,50 8,50 0,30 0,4,0,5 30 x 0,6 0,70 0,30 0,4, x 0,3,00 9,4 0,35 0,8,,5 50 x 0,6,0 7,60 0,35 0,8 3, x 0,3,40 6,5 0,40 0,3 3, x 0,3, 4,7 0,40 0,3 3, x 0,3 3,0 3,94 0,40 0,3 4, x 0,3 3,40 3,4 0,40 0,3 4, x 0,4 4,50 0 0, 6, x 0,4 6,30,6 5 7, x 0,4 7, ,40 60
12 FLY Application : Low voltage thick wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 6 x 0,,0 37,0 0 0,, x 0,,30 4,70 0 0,,50 3 x 0,,50 8,50 0 0,,70 4,5 30 x 0,6 0,70 0 0, 3, x 0,3,00 9,4 0 0, 3,30 6,5 50 x 0,6,0 7, , x 0,3,40 6, , x 0,3, 4, , x 0,3 3,0 3, , x 0,3 3,40 3, , x 0,4 4,50,00 0 6, x 0,4 6,30,6,00 0 8, x 0,4 7, 43,30,04 0, x 0,4 9,00 7,30,04, x 0,4 0 0,368,50,0 3, x,50 9,50,0 5, x 4, 6,60,8 8, x 6,50 3,60,8 9,70 50
13 FLRYW Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 5 C(3000 h) : Soft annealed plain copper : Class C (5 C) PVC and RoHS Compliant Standard : ISO 67 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside at 0 C nom. min. max. diameter (no x mm) 0, 7 x 0, 0 84,40 0,0,0,6 0,35 x 0, 0 54,40 0,0,40 4,5 6 x 0,,0 37,0 0,8 0,,70 6,6 5 4 x 0,,30 4,70 0,30 0,4, x 0,,50 8,50 0,30 0,4,0,5 30 x 0,6 0,70 0,30 0,4, x 0,3,00 9,4 0,35 0,8,,5 50 x 0,6,0 7,60 0,35 0,8 3, x 0,3,40 6,5 0,40 0,3 3, x 0,3, 4,7 0,40 0,3 3, x 0,3 3,0 3,94 0,40 0,3 4, x 0,3 3,40 3,4 0,40 0,3 4, x 0,4 4,50 0 0, 6, x 0,4 6,30,6 5 7, x 0,4 7, ,40 60
14 AVSS Application : Low voltage super thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO D 6 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 0,3 7 x 0,6 0 50,0 0,30 0,4,40,50 5 0,3 f 9 x 0,6 0, 0,30 0,4,40, x 0,3,00 3,70 0,30 0,4,60,70 7 f 9 x,00 34,60 0,30 0,4,60, f 9 x 0,3,0 3,60 0,30 0,4 0,90 9,5 5 9 x 0,4,0,70 0,30 0,4 0,90 0,5 9 x,50 4,90 0,30 0,4,0,0 4,5 f 37 x 0,,50 4,60 0,30 0,4,0,0 4 f 37 x 0,6 0 9,50 0,40 0,3,60,70
15 AVS Application : Low voltage thin wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO D 6 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 0,3 7 x 0,6 0 50,0 0 0,40 0,90 6 0,3 f 5 x 0,8 0,90 0 0,40 0, x 0,3,00 3,70 0 0,40,00,0 8 f 0 x 0,8,00 36,70 0 0,40,00,0 8 5 f 30 x 0,8,0 4,40 0 0,40,0,30 5 x 0,3, ,40,0,30,5 6 x 0,3,50 4,30 0 0,40,50,60 6,5 f 50 x 0,8,50 4,70 0 0,40,50, x 0,3,90 8,8 0 0,40,90 3,0 4 f 37 x 0,6 0 9,50 0 0,40,, x 0,3,40 5,59 0 0, 3,60 3, x 0,3 3,00 3, ,40 4,60 58
16 AV Application : Low voltage thick wall cables for vehicles Rated Temperature : - 40 C to + 05 C(3000 h) : Soft annealed plain copper : Class B (05 C) PVC and RoHS Compliant Standard : JASO C 3406 Nominal Number of wires cross-section and max. diameter max. diameter Max. resistance thickness Cable Outside diameter at 0 C nom. min. nom. max. (no x mm) 7 x 0,3,00 3,70 0 0,,0,40 0 f 0 x 0,8,00 36,70 0 0,,0, f 30 x 0,8,0 4,40 0 0,,40,60 5 x 0,3, ,,40,60 3,5 6 x 0,3,50 4,30 0 0,,70,90 8,5 f 50 x 0,8,50 4,70 0 0,,70, x 0,3,90 8,8 0 0, 3,0 3,40 6 f 37 x 0,6 0 9,50 0 0, 3,00 3, x 0,3,40 5, , 4,0 40 3f 6 x 0,6,40 5, , 4, x 0,3 3,00 3, ,60 4, x 0,45 3,70,3 0 5,50 5, x 0,45 4,50 4,00 0 6,50 6, x 0,45 5,40,38,0 8 7,60 8, x 0 6,0 87,0 8 8,30 8, x 0 8,00 0,40, 0, x 0 8,60 0,,40,,40, x 0 9, 0,337,60,8 3,00 3, 5
17 ANV Cables with thick isolation Cross Section No. & 6x x0.9 3x0.9,5 7x0.5,5 45x x x0.9 0 x x x x x x x x0.49 Nominal Min. 0,44 0,44 0,44 0,44 3,0 0,0 0,3,07,3,07,5,5,5,5,6,34,6,34 Outer min. max.,3,,5,3,7,6 3,0 3, 3,6 3,9 4,4 4,5 5,0 5,7 6,5 7, 8,3 9,6 0,4,6,3 3,5 5,0 5,5 7,5 8,0 9, 9,7 Max. resistance at 0 C 37, 4,7 8,5,7 7, Outer min. max.,,3,,5,6,9,7,,9,3,,6,4,8,6 3,0 3,0 3,4 3,3 3,8 3,7 4, 3,9 4,5 5, 6,0 6,9 7,9 8,5 9,4 Max. resistance at 0 C 84,8 54,4 37, 4,7 8,5, , ,3 4,5 7,3 9, Cables with thin isolation Cross Section No. & 0, 7x0.0 0,35 x0.0 6x x0.9 3x0.9,5 7x0.5 8x0.9,5 45x x x x x0.9 0 x x x0.39 Nominal Min. 0,30 0,4 0,30 0,4 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,35 0,8 0,40 0,3 0,40 0,3 0,45 0,36 0,45 0,36 0 0, 5 5
18 Silicone Cables NGFAF flexible Cross Section 5,5, Nom.,0, Outer min.,,4,5,9 3,5 4, 5, 6,4 8,0 9,5 5,, 3,7 5,3, 9,7 05,5 Outer min.,0,,3,6 3, 8,7,6 4,5 9,9 3,3 NGFA rigid Cross Section 5,5,5 Nom. Rated Temperature: -60 C / + C
19 Halogen-free flexible single core cables 05Z-K Cross Section No. & 6x x0.9 3x0.9 Outer,9,3,4 Max. resistance at 0 C 39,0 6,0 9, ,00,00,0,0,40,40,60 Outer,9 3,5 4, 4,8 6,0 7, 8,8 9,7,5 3,3 5,4 Max. resistance at 0 C 3,30 7,98 4,95 3,30,9, Z-K Cross Section No. &,5 7x0.5,5 45x x x0.9 0 x x x x x x x0.39 Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Rated Temperature: 70 C - Rated Voltage: 05Z-K: 300V / 500V 07Z-K: 450V / 750V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc.
20 Halogen-free rigid and flexible single core cables 07Z-U Cross Section No. &,5 x.38,5 x.78 4 x.6 6 x.76 Outer,8 3,4 3,8 4,3 Max. resistance at 0 C, 7,4 4,6 3,08 0 3, 45 63, ,00,00,0,0 Outer 3,0 3,6 4, 4,7 5,9 7,0 8,4 9,4 Max. resistance at 0 C,0 7,4 4,6 3,08 3,5 7 4,4 3,8 47,6 67,7 09, 67,5 6, 347,8 07Z-R Cross Section No. &,5 7x0.5,5 7x x x.0 0 7x x x x.55 Product Description Applications - Rigid or flexible copper conductor - Halogen-free thermoplastic insulation - Rated Temperature: 70 C - Rated Voltage: 450V / 750V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc.
21 Halogen-free flexible multi-core cables H03ZZ-F Cross Section No. & x0.50 6x0.9 x0.75 4x0.9 3G0.50 6x0.9 3G0.75 4x0.9 4G0.50 6x0.9 4G0.75 4x0.9 Jacket Outer 5,0 5,4 5,4 5,8 5,8 6,3 Max. resistance at 0 C Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Halogen-free thermoplastic jacket - Rated Temperature: 70 C - Rated Voltage: 300V / 300V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc
22 Halogen-free flexible multi-core cables H05ZZ-F Cross Section No. & x0.75 4x0.9 x.00 3x0.9 x.50 7x0.5 x.50 45x0.5 x x0.9 3G0.75 4x0.9 3G.00 3x0.9 3G.50 7x0.5 3G.50 45x0.5 3G x0.9 4G0.75 4x0.9 4G.00 3x0.9 4G.50 7x0.5 4G.50 45x0.5 4G x0.9 5G0.75 4x0.9 5G.00 3x0.9 5G.50 7x0.5 5G.50 45x0.5 5G x0.9 Jacket,0,,,,0,,4,,,4 Outer 6, 6,4 7,4 9,0 0,4 6,6 6,8 8, 9,8,3 7, 7,6 9,0,7 8, 8,3 0,,9 3,9 Max. resistance at 0 C 6 9,5 3, ,5 3, Product Description Applications - Flexible copper conductor - Halogen-free thermoplastic insulation - Halogen-free thermoplastic jacket - Rated Temperature: 70 C - Rated Voltage: 300V / 500V - Suitable for populated locations with fire risk, such as shopping centers, hotels, schools, business centers, etc
23 Telephone cables VDV x x VDV x x VDV 3 x x VDV 4 x x VDV 5 x x VDV 6 x x VDV 0 x x VDV 5 x x VDV 0 x x VDV 30 x x VDV 50 x x VDV 00 x x VDV x x VDV x x VDV 3 x x VDV 4 x x VDV 5 x x VDV 6 x x VDV 0 x x VDV 5 x x VDV 0 x x VDV 30 x x VDV 50 x x VDV 00 x x VDV x x VDV x x VDV 3 x x VDV 4 x x VDV 5 x x VDV 6 x x VDV 0 x x VDV 5 x x VDV 0 x x VDV 30 x x VDV 50 x x VDV 00 x x VDV x x VDV x x VDV 3 x x VDV 4 x x VDV 5 x x VDV 6 x x VDV 0 x x VDV 5 x x VDV 0 x x VDV 30 x x VDV 50 x x VDV 00 x x VDV Product Description Applications - Bare or tinned copper conductor - Color-coded PVC insulation - PVC jacket cord, flat type - These cables are used for signal transmission at fixed indoor installations.
24 Underground buried type communication cables PD-PAP x x 0.40 PD-PAP 4 x x 0.40 PD-PAP 6 x x 0.40 PD-PAP 0 x x 0.40 PD-PAP 0 x x 0.40 PD-PAP 30 x x 0.40 PD-PAP 50 x x 0.40 PD-PAP x x 0.50 PD-PAP 4 x x 0.50 PD-PAP 6 x x 0.50 PD-PAP 0 x x 0.50 PD-PAP 0 x x 0.50 PD-PAP 30 x x 0.50 PD-PAP 50 x x 0.50 PD-PAP x x 0.60 PD-PAP 4 x x 0.60 PD-PAP 6 x x 0.60 PD-PAP 0 x x 0.60 PD-PAP 0 x x 0.60 PD-PAP 30 x x 0.60 PD-PAP 50 x x 0.60 PD-PAP x x 0.90 PD-PAP 4 x x 0.90 PD-PAP 6 x x 0.90 PD-PAP 0 x x 0.90 PD-PAP 0 x x 0.90 PD-PAP 30 x x 0.90 PD-PAP 50 x x 0.90 PD-PAP Product Description Applications - Annealed copper conductors - Foam-Skim PE insulation - Star quad construction - PE inner sheath - Aluminum foil (double side copolymer coated) - PE outer sheath - Telephone cables for VF transmission and digital systems. - Suitable for direct burial.
25 Drop wire with steel supporting wire BAP-DT x x x x Product Description Applications - Two copper conductors with supporting steel wire in center. - PVC insulation - These cables are designed for telephone subscriber connections as exterior installation, especially in rural areas or long distance subscriber connections.
26 Data, diaphone and speaker cables Data cables x 0.mm....5mm 3 x 0.mm....5mm 4 x 0.mm....5mm 5 x 0.mm....5mm 6 x 0.mm....5mm 8 x 0.mm....5mm 0 x 0.mm....5mm x 0.mm....5mm 4 x 0.mm....5mm 6 x 0.mm....5mm 8 x 0.mm....5mm 0 x 0.mm....5mm x 0.mm....5mm 4 x 0.mm....5mm Diaphone cables 4 x 0.mm 6 x 0.mm 8 x 0.mm 0 x 0.mm x 0.mm Product Description - Bare stranded copper conductor - Color-coded PVC insulation - PVC jacket cord Speaker cables
27 Coaxial cables Coaxial cables RG 59 U / 4 RG 6 U / 4 RG 58 A / U RG U / 4 TWINAXIAL 00 Product Description Applications - Tinned or bare copper conductors. - PE or FPE insulation - Aluminum shield - PVC jacket - 75 ohm cable suitable for TV systems or satellite receivers.
28 Flat cables Flat cables Product Description Copper: 7x0.0mm or 0.50mm Number of conductors: 4 Minimum isolation thickness: 0.40mm Rated temperature: 70 C Rated voltage: 300V If requested, a stripe on leading edge is possible
29
30 NYM Application: In dry, damp and wet locations on premises and in store rooms with fire and explosion hazard. Can be used outdoors but cannot be buried underground. Techinical data:.5mm 0mm are single-core, 0 and 6mm are multi-core. is TI thermoplastic. Twisted. Outer sheath color is grey. Max. conductor temperature: 70 C Rated voltage: 300/500V Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C x.5,38,4 8 6, x.5 0, ,8 x4,6,4,4 8 4,56 x6,,4,4 77 3,03 x0-7 4,0,0,6 6,4 8 3 x6-7 5,0,0,6 8,6 600,5 3x.5,38,4 9, 36, 3x.5 0,4 89 7,8 3x4,6,4 6 4,56 3x6,,6 3, ,03 3x0-7 4,0,0,6 7, x6-7 5,0,0, ,5 4x.5,38,4 0 63, 4x.5 0,4,3 3 7,8 4x4,6,6 3,4 36 4,56 4x6,, ,03 4x0-7 4,0,, x6-7 5,0,0,6 07,5
31 YVV(NYY) Application: Power cable, underground, in ducts, indoors and outdoors, in pure or salt water, for power stations industrial plants and switching stations. Technical data:,,3 or 4 cores. Solid conductor between.5 and 0mm; stranded copper conductor between 0 and 400mm. Cores are twisted together and covered with an inner covering and black outer sheath. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C Rated Current Ground Air x4,6,5 8,9 4, x6,8,5 9,4, x0-7 4,,5, x6-7 5,,5,7, x5 7 6,4,5, x ,7,5 4, x50 9 9,,5 5,6 0, x70 9,5 7, 0, x ,7,6 9,4 0, x0 37 4,4,6, x , 3 0, x ,0 5,7 0, x40 6, 9 0, x.5,38, 30 x.5 3 7, x4,6,0 4 4, x6,8,0 5 3, x0-7 4,, x6-7 5,,0 8, x5 7 6,4, x ,7, x50 9 9,,4 9 0, x70 9,4, 35 0, x95 9,7,6, x0 37 4,4,6, x ,,6 0, x ,6,0,6 5 0, x40 6, ,
32 YVV(NYY) cont. Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C,38,5 Rated Current Ground Air, x.5 3x.5,5 7, x4,6,0 4,5 4, x6,8,0 5,5 3, x0-7 4,, x6-7 5,,0 0, x5 7 6,4, 4, x ,7, x50 9 9,,4 3 0, x70 9,4, 36 0, x95 7,7,6, x0 37 4,4,6, 43, x ,,6 49,5 0, x ,0,6 54,5 0, x40 6, 3 6 0, x ,,0, x ,4./ x ,7./ x ,.4/., 3 0, x /., 38 0, x ,7.6/.4, 44, x ,4.6/.4, x ,.8/.4,8 5 0, x / , x /.6 3, 66 0, x.5,38 3, x.5 4 7, x4,6,0 6 4, x6,8,0 7 3, x0-7 4,, x6-7 5,,0 3, x5 7 6,4, x ,7,, x50 9 9,,4, 36 0, x70 9,4, 40 0, x95 9,7,6, x0 37 4,4,6, x ,,6 54 0, x , , x40 6, ,
33 YVV(NYY) Control Cables Application: Power cable, underground, in ducts, indoors and outdoors, in pure or salt water, for power stations industrial plants and switching stations. Technical data: More than four.5 or.5mm wires are twisted together. s are insulated with PVC, twisted together and covered with inner and outer sheaths. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C 5x.5,38 3, 60 7x.5,38 4, 30 0x.5,38 7, 430 x.5,38 8, 445 4x.5,38 9, 4 6x.5,38 0, 550 9x.5,38, 600 x.5,38, 700 4x.5,38 5, 0 30x.5,38 6, 90 40x.5,38 8, 300 5x.5 6 7, x.5 6 7, x.5 7,8 550 x.5 7, x.5 7, x.5 7, x.5 3 7,8 850 x.5 4 7,8 90 4x.5 7 7, x.5 8 7, x.5, 33 7,8 500
34 YVZ3V-R (NYFGby) Application: Underground, indoor and outdoor installation, where better mechanical protection or higher is required resistance to higher tensile stress is required. Technical data: There is an armour of galvanized flat steel wires between inner covering and outer sheath against mechanical stresses. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C Rated Current Ground Air 3x ,4, x ,7, x ,,4, 35 0, x ,4, 4 0, x ,7,6,6 47, x ,4, ,,6,6 5 3x , x , , x40+0 6, 3,4 69 0, x0 3,6,0, x6 7 5,,0 6, x5 7 6,4, x ,7, x50 9 9,,4, 38 0,
35 H05RR-f (NMH) Note: Wires are tinned or untinned and diameters are 0.0 Application: In dry, damp and wet spaces, outdoors, on agricultural premises, for medium-stress portable tools such as grinders, drills, electrical ovens, lamps, where cables are exposed to severe stress due to bending and twisting. Technical data: Fine stranded copper, rubber sheath. Max. conductor temperature: 60 C Rated Number of Outer Sheath Outer Resistance Crosssection Strands at 0 C x0.75 4, 7,5 6,7 8 x 3,4 7,7 0,0 9 x.5,7 8,4 3,7 4 x.5,3, 8, 73 x4 7,7,,3 5, x0.75 4, 8 6,7 99 3x 3,4 8,4 0,0 5 3x.5,7 9 3,7 36 3x.5,3, 8, 0 3x4 7,7, 3 5, x0.75 4, 8,6 6,7 7 4x 3,4 9, 0,0 40 4x.5,7, 0 3,7 7 4x.5,3,,5 8, 66 4x4 7,7, 4,5 5,09 3 4x6 90 3,3,6 6,5 3,39 5 4x0 38 4,0,6 9,95 755
36 H07RN-f (NSH-öu) Note: There is a textile braiding between inner covering and outer sheath. Application: In dry and damp locations, outdoors, mobile generators and motors, trains, agricultural tools etc, where mechanical stresses are high. Technical data: Tinned or untinned fine stranded copper, rubber insulation and sheath with single or multi-core cables. Max. conductor temperature: 60 C Rated Number of Crosssection Strands Inner Sheath Outer Sheath Outer Resistance at 0 C x6 50 5,5,4 -,6 4,4 30 x5 0 6,5, x35 0 8,6-7, x x70 40,0 -, x ,5, ,4 -,,5 5 x x ,4 -, x.5,7,0,6 4 3,7 3 x.5,3,0,6 6 8, 30 x4 7,7,0, 9 5,09 46 x6 90 3,3,0, 0 3, x0 38 4,,,, x.5,7,0,6 4,5 3,7 63 3x.5,3,0,6 6,5 8, 35 3x4 7,7,0, 9,5 5, x6 90 3,3,0, 3, x0 38 4,,,5,95 3x6 50 5,,4, 5, x6+0 50/38 5/4./.,4, 5,5.4/ x5+6 0/50 6.5/5.4/.,6,5 3, x35+6 0/50 8/5.4/.,6, x /0 9/6.5.6/ x /0 /8.6/.4,0 3 3, x / /9.8/.6, x /40 6/.8/.6,4 4 6, x /40 8/ /.6,8 4,5 69, x.5,7,0,6 5,5 3, x.5,3,0,6 7,5 8, 40 4x4 7,7,0, 5, x6 90 3,3,0,,5 3, x0 38 4,,, 5, x6 50 5,,4, 8,4 40
37 H07RN-f (NSH-öu) cont. Note: Wires are 0.0mm tinned or untinned, fine stranded. Insulated conductors twisted together with fillers. Rated Number of Outer Resistance Crosssection Strands at 0 C Inner Sheath Outer Sheath 0x.5,7, 3 3, x.5,3,4, 7 8, 860 x.5,7, 4 3, x.5,3,4, 8,5 8, 990 4x.5,7,4, 6 3, x.5,3,4 30 8, 05 6x.5,7,4,, 6 3, x.5,3,4,5 30 8, 87 9x.5,7,4, 7,5 3, x.5 x.5,3,6,5 3,5 8, 39,7,4, 9 3,70 97 x.5,3,6,5 34 8, 547 4x.5,7,6,5 30 3, x.5, , 0 5x.5,7,4,6 6,5 3, x.5,3, 0 8, 498 6x.5,7, 9,5 3, x.5,3,,5 8, 567 7x.5,7, 0 3, x.5,3,,5 8, 69 8x.5,7,,5 3,70 5 8x.5,3,4, 4,5 8, 74
38 H0N-d (NSLFF-öu) Welding Cables Application: In dry,damp and wet locations, also outdoors for welding machines. Technical data: 0.0mm stranded copper is wrapped with a seperator, which is covered with an oil and flame resistant rubber sheath. Max. conductor temperature: C Rated voltage: 500V Rated Number of Crosssection Strands PE Seperator Outer Sheath Outer Resistance at 0 C ,5 9,5, , , , , ,5, 8,
39 H03RT-f (NSA) Application: For applications such as light portable heating appliances, portable lamps or electric irons, where mechanical stresses are low. Technical data: Finely stranded copper, insulated with rubber, twisted with textile fillers and covered with textile braiding. Max. conductor temperature: 60 C Rated voltage: 300V/300V Rated Number of Core Braided Outer Resistance Crosssection Strands at 0 C 3x0.75 4,,9 7, 6,70 5 3x 3,4 3, 7,5 0, x 3,4 3, 8,6 0,00 73
40 H05VV5-f (TTR) Control Cables Note: Insulated wires are twisted together with fillers. Number-coded. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 5x0.75 4, x0.75 4, x0.75 4, x0.75 4, x0.75 4,, 3,5 6 0 x0.75 4,, x0.75 4,, 5, x0.75 4,, x0.75 4,, x0.75 4,, x0.75 4, x0.75 4, x 3,4 9,5 9,5 37 6x 3,4 9,5 63 7x 3,4,5 9,5 96 0x 3,4,4 4,5 9,5 77 x 3,4,4 5 9,5 30 4x 3,4,4 6,5 9, x 3,4 8 9, x 3,4 8 9,5 49 4x 3,4 9,5 9, x 3,4 9,5 735
41 H05VV5-f (TTR) Control Cables cont. Note: Insulated wires are twisted together with fillers. Number-coded. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 5x.5,7, 0,4 3,3 75 6x.5,7,,5 3,3 07 7x.5,7, 3,3 34 0x.5,7,4 5,5 3,3 330 x.5,7,4 6 3, x.5,7,4 6,5 3, x.5,7,6 7,5 3, x.5,7,6 8,5 3,3 5 x.5,7,6 9,5 3, x.5,7,5 3, x.5,7 5 3,3 90 5x.5,3, 3 7, x.5,3, 5 7, x.5,3,4 8,5 7, x.5,3,4 9,8 7, x.5,3,6 7, x.5,3,6,5 7, x.5,3 3,5 7, x.5,3 4,5 7, x.5,3 7,5 7, x.5,3 9 7, x.5,3 3 7, x.5,3 3,5 7,98 775
42 Water pump motor cables Application: In connections for water pumps in wells with pure/salty water. Flexible. Medium mechanical stress. Technical data: is insulated with PVC/A. Twisted insulated cores are covered with special rubber inner covering and PVC outer sheath. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Note: Other crosssections can be produced on request. Rated Number of Outer sheath Outer Resistance Crosssection Strands at 0 C 4x.5,7,6 3,3 0 4x.5,3 3,6 7,98 5 4x4 7,7 6, x6 90 3, x0 38 4, x6+0 50/38 5/4./. 3,5. 0 3x5+6 0/50 6.5/5.3/ x35+6 0/50 8,5.3/
43 YSLY-j Application: In dry and damp interiors, esp. industrial environmental conditions, but not outdoors. Technical data: Resistant to oil and chemicals. Flexible. Finely stranded bare copper wire. PVC insulations are black and marked with white numbers & yellow/green. Outer sheath is grey and oil and flame resistant. Max. conductor temperature: 70 C Rated voltage: 300/500V Rated Outer Rated Outer Crosssection Crosssection x0.5 4,8 35 5G0.75 3, x0.5 5, 4 6G0.75 4, 350 4x0.5 5, G0.75 5,9 4 5x0.5 6, 63 4G0.75 7, x0.5 6,7 8 50G0.75 9, 6 G0.5 8,9 3 6G G0.5 9, G G G0.75 3,6 09 G0.5,7 00G0.75 6,4 7 5G0.5,4 6 X 5, G0.5 3, G G0.5 4, X G0.5 5, G 6,5 79 5G0.5 7,3 57 4X 6,5 79 6G0.5 8, G 7, 94 65G0.5 9, X 7, 94 G0.5, 7 6G G0.5 3, G 8 6 X0.75 5,4 45 7X 8 6 3G0.75 5,7 55 8G 9,5 49 3X0.75 5,7 55 9G G0.75 6, 66 0G 0, 4X0.75 6, 66 G 05 5G0.75 6,7 79 X 05 5X0.75 6,7 79 4G, 38 7G0.75 7,3 0 6G 66 7X0.75 7,3 0 8G, G0.75 9,4 37 8X, G0.75 9,6 50 0G 3,4 330 G0.75 9,9 7 0X 3,4 330 X0.75 9,9 7 5G 4, G G 5, 44 6G0.75, 0 34G 7, 55 8G0.75, G 7,4 578 G
44 YSLY-j cont. Rated Outer Rated Outer Crosssection Crosssection 40G 8, G.5 6, G 8,8 66 G.5 8, G 797 X.5 7,5 0 56G, G.5 8, 3 6G, 958 4G.5 8, G 3, G G 5,3 5 7G.5, 67 00G 8,3 560 G.5 4,8 445 X.5 6,3 68 4G.5 5,8 55 3G.5 6,7 84 8G.5 7,8 6 3X.5 6,7 84 5G G.5 7, 04 34G.5 4,4 08 4X.5 7, 04 50G.5 9, G.5 8, 8 3G4 9,9 0 5X.5 8, 8 4G4 49 7G.5 8,9 66 5G4, 305 7X.5 8,9 66 7G4 3, G.5 97 G4 7, G.5,4 3G6,7 89 0G.5,6 43 4G G.5,6 58 5G6 4,5 447 G G X G0 4, G.5,7 33 4G0 6, 590 6G.5 3,4 36 5G0 8, 7 8G.5 4, G G.5 5, G6 8, G.5 6, G6, 370 6G.5 7,3 58 7G6 3, G.5 7, G5 3, G.5 9, G5 6, G.5, G35 6, G.5 3, G35 30, 635 6G.5 5, 309
45 NYRY Application: Underground, indoor and outdoor installation, where resistance to high tensile or mechanical stress is required. Technical data: There is an armour of galvanized wires between inner covering and outer sheath against mechanical stress. Max. conductor temperature: 70 C Rated voltage: 0.6/kV Rated Outer sheath Outer Crosssection x.5,38,5 300 x.5,78 3,5 343 x4,6 5,5 468 x6,76 7,5 67 x0 3, x.5, x.5, x4,6 6, x6,76 7, x0 3,55 9, x.5,38 3,5 38 4x.5, x4, x6, x0 3,55,5 50
46 Some of our special cables
47 Cable harnesses We are able to produce a wide range of cable harnesses.
48
49 A few pictures from our factories in Istanbul and Manisa:
50 Istanbul Factory: Ferhatpasa Cad. Sehit Naci Cakar Sok. No: Bayrampasa Istanbul - TURKEY Manisa Factory: Organize Sanayi Bolgesi Cumhuriyet Bulvari No:6 Manisa - TURKEY Phone: , , Fax: elki@elkicable.com
Power & Control Cable IEC
(2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationFTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings
HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for
More informationPower & Control Cable IEC
(2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationApprovals (Norm references)
ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,
More informationConductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5
Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationTechnical attributes
Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,
More informationTelephone Cables Fire Warning Cables
Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free
More informationPower & Control Cables. U o. /U 0.6/1 kv - IEC
Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations
More informationAny inquiries, please feel free to contact or Caledonian
Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationIndustry Cables Special cables for industrial applications General Catalogue
Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the
More informationVDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications
VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,
More informationPower & Control Cables
The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.
More informationÖLFLEX CLASSIC 110 CY
Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationTRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire
Low voltage - Energy, cabling, signalling and control TRIFLEX H07RN-F Structure and, physical, mechanical requirements: Low Directive: RoHS Directive: EN 50525-2-21 2014/35/EU 2011/65/EU Standard: Class:
More informationÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.
Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with
More informationCF270.UL.D.
Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:
More informationSolid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816
Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationPRODUCT INFORMATION H07V-K
GmbH PRODUCT INFORMATION European cable type certification Cables' marking also stands for the international endorsement of national certification institutes' testing marks and certificates,
More informationH07RN-F TITANEX (industrial flexible)
Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has
More informationCABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue
CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main
More informationUNSHIELDED MULTI CONDUCTOR
PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,
More informationFlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable
Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationH05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.
H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial
More informationPRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved
Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info
More informationÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V
PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:
More informationPOLYCAB WIRES PVT. LTD.
Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600
More information300 V TTR KABLOLAR 300 V MULTICORE CABLES H03VV-F H03V2V2-F H03V2V2-F 105 C H03VVH2-F H03V2V2H2-F H03V2V2H2-F 105 C TS 9760 HD 21.5 S3 - VDE 0281-5 HD 21.5 S3 TS HD 21.12 S1 - VDE 0281-12 HD 21.12 S1 TS
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V
More informationDNV-GL HH CE RoHS-II conform
Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable
More informationCatalogue. Index INDUSTRIAL CABLE
Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL
More informationPOLYCAB WIRES PVT. LTD.
Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410
More informationFR-N1X1G1. Low voltage - Energy, cabling, signalling and control
Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2
More informationFlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable
Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V
More information600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH
More informationIEEE 1580 TYPE T/N CABLE
1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR
More informationINDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS
INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from
More informationFTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv
Low voltage - Energy, signalling and control FTG10M1-0,6/1 kv FTG10OM1-0,6/1 kv Fire Structure and, physical, mechanical requirements: CEI 20-45 Fire propagion: EN 60332-3-24 (CEI 20-22 III) Flame propagion:
More informationCables for cable carriers and reels SYSTEMS IN MOTION
Cables for cable carriers and reels SYSTEMS IN MOTION 8e/en 2016 Content PVC flatform cables (H)07VVH6-F H07VVH6-F... 4 PVC flatform cables, shielded YCFLY... 6 Neoprene flatform cables NGFLGÖU UL... 8
More informationElectronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N
Electronic Cable CO N N E C T I N G T E C H N O LO G Y W I T H P E R F O R MA N C E & P R E C I S I O N Our Commitment Our Commitment to our customers is simple - we deliver even when others can t. As
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationis the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.
is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities
Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation
More informationCF11.LC / CF11.LC.D CF14.CAT5
TPE - e-chain - Bus cable for maximum load requirements (Class 6.6.4): shielded, oil- and biooil-resistant, PVC- and halogen-free as well as hydrolysis- and microbe-resistant. Overview Example drawing
More informationFlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E
Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS
ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................
More informationArt.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see
More informationLDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.
INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded
More informationWires that don t catch fire
Wires that don t catch fire Havells range of heat resistant & flame retardant wires w.e.f. 1st July, 2017 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial
More informationwww. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL
Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications
More informationData sheet chainflex CF240
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More informationData sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.
Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire
More informationbuildings. They are also used for industrial electrification regular intervals along with the size of the wire.
P.V.C. INSULATED SOLID/ STANDED COPPE CONDUCTO CABLE Application : These cables are used for wiring domestic and commercial buildings. They are also used for industrial electrification Features : Manufactured
More informationCatalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod
Z V ET L I Т Traditional reliability Catalogue Cables, wires, aluminium wire rod, aluminium alloys wire rod www.zvetlit.ru Contents 1 About company 2 Analogues (according to IEC, VDE, PN, HD, BS) 4 Power
More informationData sheet chainflex CF8821
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More informationINFORMATION. Hybrid cables. Description
Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description
More informationConductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)
Outer jacket: Pressure extruded PVC mixture Inner jacket: Pressure extruded, gusset filling PVC mixture Conductor: Fine-wire strand consisting of bare copper wires 6 1 Core insulation: Mechanically highquality
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements
PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application
More informationPVC SHEATH FLAME RETARDANT CABLE TO IEC60332
600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit
More informationData sheet chainflex CF6
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture
More informationCables and multistrand wires Main catalog. Cableline Test & Measurement
Cables and multistrand wires Main catalog Cableline Test & Measurement STÄUBLI ELECTRICAL CONNECTORS Long-term solutions Expert connections Stäubli Electrical Connectors is a leading international manufacturer
More informationPRODUCT CATALOGUE Volume 4
PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road
More informationCABLED SINGLE CONDUCTORS
CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of
More informationDRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.
DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,
More informationFLEX-O-POWER FLEXIBLE WELDING
EQUIPMENT cables FLEX-O-POWER FLEXIBLE WELDING & POWER CABLE High conductivity bunched flexible annealed copper conductors, insulated with a soft flexible grade PVC suitable for welding and power purposes.
More informationINSTRUMENTATION CABLE
APPLICATION Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields. Design
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing
More informationNYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed
More informationData sheet chainflex CF140.UL
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip
More informationArt.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the
More informationCABLED TWISTED PAIRS CONDUCTORS
CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete
More informationENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics
ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals
More information75 OHM COAXIAL CABLE (RG6)
RG6 CABLE (RG6) Drop Cable RG6 UL listed as type CMG for indoor cables. RG-6. 18 AWG copper covered steel with nominal diameter of 0.040 inch (1.02mm). Gas injected foam polyolefin insulation. Nominal
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include
More informationLS Total Solution for Photovoltaic
LS Total Solution for Photovoltaic Solar Cable and Components Solar Cable (Max 120 ) Solar Cable (EPR ) Solar Cable (XLPE ) Solar Cable (Main Power Line) Solar Cable (Direct Burial) Solar Cable (Steel
More informationFR-3S Fire Resistant Cables
FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and
More informationCables for Railway Technology
Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual
More informationCAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems
Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022
More informationCable systems We offer you the essential components for a future-oriented e-mobility.
Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR THE LAMP AND LIGHT INDUSTRY. tailex / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR THE LAMP AND LIGHT INDUSTRY tailex / Fotolia CONTENT page < Who we are...............................................................................
More informationAirfield Ground Lighting
Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees
More informationHYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY
HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationHigh Voltage Aluminum, Smooth Aluminum Shield/Sheath
High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationLCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable
ed Primary UD EPR ed Primary UD EPR Cable Aluminum or Copper Conductor. EPR Insulation. Copper Longitudinal Corrugated Tape (). Low Density Polyethylene Jacket. APPLICATIONS Predominantly used for primary
More informationList Price w.e.f. 08th May, 2018 s s s s s s s
w.e.f. 08th May, 2018 HRFR/FR-LSH/HFFR/ PVC Inulated Indutrial Cable Multicore Round PVC Cable Flat Three Core Indutrial Cable for Sumerible ue Telecom & Co-axial Cable LAN Cable CCTV Cable Speaker Cable
More informationSY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath
Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical
More information