4 Solar Cable and Components Solar Cable (Max 120 ) Solar Cable (EPR ) Solar Cable (XLPE ) Solar Cable (Main Power Line) Solar Cable (Direct Burial) Solar Cable (Steel Armor Protected) Ribbon Wire for solar module Junction Box (Crystalline solar module) Junction Box (Thin film solar module) Cable Connector (Locking Type) Cable Connector (Unlocking Type) Branch Connector (MFF, FMM type) Heat Shrinkable Tube Cable Gland Power Cable Medium Voltage Cable (22.9kV CN/CV-W) Communication Cable Low Voltage Cable (F-CV/TFR-CV) Ground Cable (F-GV/TFR-GV) Low Voltage Cable (NYY-J/O) Low Voltage Cable (HIV) Low Voltage Cable (H07RN-F/ Harsh Condition) Bus Duct Data Cable (UTP) Data Cable (HFBT) Signal Cable (RS-422/485) Data Cable (Optical Fiber Cable) The Others Conduit Crimping Tool Cable Stripping Plier Contents _Solar Cable and Components 6 _Power Cable 22 _Communication Cable 33 _The Others 38
5
6 SolarSol Solar Cable and Components SolarSol TM LS Cable, the Leading Solution provider of Cable and Cable-related components, has developed cables and components for photovoltaic industry. LS Cable provides all kinds of cable and component for the construction of large solar farm, roof-top and BIPV (Building Integrated Photovoltaic) application. LS Cable s special solar cable can guarantee over 20 years of life time that can make the operation of solar farm successful. LS Cable also developed the ribbon wire and junction box kit for solar module manufacturers. LS Cable completed the product line-up for customers like Engineering and Construction company in solar industry, and this means that customer can be supplied all cables and components needed in solar farm by one contract. Solar Cable Rated Voltage No. of Core Cross Section (mm 2 ) Sheath Screening /Armour ( ) Material of Tinned Cu, SC-M-PV1 XL Compound 1 2.5, 4.0, 6.0 XL Compound ~ +120 stranded 7 Tinned Cu, SC-M-EPR EPR 1 2.5, 4.0, 6.0 XL Compound ~ +90 stranded 9 Reference (page) SC-M-XLPE Tinned Cu, XLPE 1 2.5, 4.0, 6.0 XL Compound ~ +90 stranded AC 600/1000V 10 SC-CN-XL DC 900/1500V HF XL Tinned Cu, XL Compound 1 10 ~ ~ +120 Compound stranded 11 Tinned Cu, SC-CN-DB XL Compound 1 4 ~ 120 XL Compound ~ +120 Strands 12 Tinned Cu, SC-M-SA XL Compound 1 4.0, 6.0 XL Compound Steel -40 ~ +90 Strands 13 Components Rated Voltage No. of Core Cross Section (mm 2 ) Materials Screening /Armour ( ) Material of Reference (page) (Sn-Pb or Sn-Pb-Ag Ribbon Wire / Sn-Ag) on Cu Junction Box (Crystalline) Junction Box (Thin Film) DC 1000V(TÜV), 600V (UL) DC 1000V(TÜV), 600V (UL) 5.8mm - - PPO (Cable O.D.) ~ mm - - PPO (Cable O.D.) ~ DC 1000V(TÜV), 5.1, 5.8 mm PPO (Locking Type) Connector - - (Cable O.D.) TPV (UnlockingType) ~ V (UL) 5.1, 5.8 mm Branch DC 1000V - - (Cable O.D.) PC ~ Heat ShrinkableTube -55 ~ , 600V PO - 120, Cable Gland PC ~ Conduit PA ~ Cable Stripping Plier / Crimper Steel
7 SC-M-PV01 SC-M-120 Solar Cable for Max. 120 Cable for junction box, Interconnection between Interconnection module between and module, modules, or or between module arry array and and connection box box Construction Sheath Bare copper, Tinned, Finely stranded (DIN VDE 0295 class 5, IEC class 5) Electron beam cross-linked copolymer Electron beam cross-linked copolymer Rated AC 600/1000 V, DC 900/1500 V Voltage (U0/U) ~ +120 Rage( ) Max. Bending 4 x O.D. Radius Properties Halogen Free Oil Resistant Chemical Resistant Approval Approval TÜV 2Pfg 1169 / TÜV(2 Pfg 1169/ ), UL 4703 UV Resistant Ozone Resistant Flame Retardant Size Outer Diameter Copper Weight Weight (mm 2 ) (AWG) (kg/km) (kg/km) size (mm 2 ) Outer 5.1Dia. 5.8 Copper 24.0 Weight (kg/km) 38.4 Weight 49.0 (kg/km) Solar Cable and Components SolarSol TM 7
8 SC-M-PV02 Solar Cable for Max. 120 Cable for junction box, Interconnection between modules, or between module array and connection box Construction Sheath Bare copper, Tinned, Finely stranded (DIN VDE 0295 class 5, IEC class 5) Electron beam cross-linked copolymer UV Sunlight resistant material Rated AC 600/1000 V, DC 900/1500 V Voltage (U0/U) - 40 ~ +120 Rage( ) Max. Bending 4 x O.D. Radius Properties Oil Resistant Approval UL4703 Chemical Resistant UV Resistant Ozone Resistant Flame Retardant Size (AWG) Cable Outer Diameter Weight (lbs/1000ft) SolarSol TM Solar Cable and Components
9 SC-M-EPR Solar Cable with EPR insulation Cable for junction box, Interconnection between modules, or between module array and connection box Construction Tinned Cu, ASTM B 33 or B 8 (Class B bare Cu, Flexible tinned Cu) Halogen-free EPR Sheath Halogen-free XL compound Rated Voltage (U0/U) Rage( ) Max. Bending Radius Properties AC 600/1000 V, DC 900/1500 V -40 ~ x O.D. Min. Flame Retardant Low Smoke Halogen Free Size (mm 2 ) Outer Diameter Weight (kg/km) Solar Cable and Components SolarSol TM 9
10 SC-M-XLPE Solar cable with XLPE insulation Cable for junction box, Interconnection between modules, or between module array and connection box Construction Sheath Bare copper, Tinned, Finely stranded (DIN VDE 0295 class 5, IEC class 5) Halogen-free XLPE Halogen-free XL compound Rated Voltage (U0/U) AC 600/1000 V, DC 900/1500 V Rage( ) -40 ~ +90 Max. Bending Radius 4 x O.D. Properties Min. Flame Retardant Low Smoke Halogen Free Size (mm 2 ) Outer Diameter Weight (kg/km) SolarSol TM Solar Cable and Components
11 SC-CN-XL Solar Cable for Main Power Line Interconnection between module array and connection box, or connection box and inverter Construction Reinforcement Sheath Bare copper, Tinned, Finely stranded (DIN VDE 0295 class 5, IEC class 5) XLPE Halogen-free XL Compound (with Al tape) Halogen-free XL Compound Rated AC 600/1000 V, DC 900/1500 V Voltage (U0/U) -40 ~ +90 Rage( ) Max. Bending 4 x O.D. Radius Properties UV Resistant Ozone Resistant Rodent Resistant Size (mm 2 ) Outer Diameter Weight (kg/km) 1X X X X X X X ,125 1X ,390 1X ,695 1X ,010 1X ,615 1X ,245 Solar Cable and Components SolarSol TM 11
12 SC-CN-DB Solar cable for direct burial Suitable for direct burial Interconnection between module array and connection box, or connection box and inverter Construction Sheath Fine wire, Tinned copper stranded (DIN VDE 0295 class 5, IEC class 5) XHHW-2 XL EVA Rated AC 600/1000 V, DC 900/1500 V Voltage (U0/U) -40 ~ +120 Rage( ) Max. Bending 4 x O.D. Radius Properties Flame Retardant Halogen Free Oil Resistant Chemical Resistant UV Resistant Size (mm 2 ) Outer Diameter Weight (kg/km) , , SolarSol TM Solar Cable and Components
13 SC-M-SA Solar cable with steel armour protected Interconnection between modules (Protected against rodents and termites) Construction Sheath Armoring Fine wire, Tinned copper strands (DIN VDE 0295 class 5, IEC class 5) XL Compound XL Compound Stainless steel wire braiding Rated Voltage (U0/U) AC 600/1000 V, DC 900/1500 V Rage( ) -40 ~ +90 (Short Circuit Temp ) Max. Bending Radius 4 x O.D. Properties Halogen Free Oil Resistant UV Resistant Flame Retardant Size (mm 2 ) Outer Diameter Copper Weight (kg/km) Weight (kg/km) Solar Cable and Components SolarSol TM 13
14 SC-M-RW Interconnect ribbon wire or bus bar for solar module Interconnection between solar cells or bus bar between solar cell strings Construction Item Specification Tolerance Thick ness Yb 0.03 width Zb±0.1 Solder thickness ( ) 20 ~ 40 Elongation (%) 25 Meandering Width 0.3/150mm 3mm After stretching a sample at a rate of 2% elongation, a meandering is measured as the length between marks of the left drawing in 150mm span 4.0/1000mm Width 3mm A meandering is measured as the length between marks in 1000mm span. Copper Wire Solder C Zb B D Yb Tupe Inter Connector Bus Bar Type of Cu (Purity) OFC (99.99%) and TPC (99.9%) TPC (99.9%) (thickness x width) 0.15 x x x x x x x x x x 6.0 Solder (Pb) Sn 60 Pb 37 Ag 3 / Sn 60 Pb 40 Solder (Pb-free) Sn 96.5 Ag 3 Cu 0.5 Solder Thickness ( ) (one side) Available Dimension Thickness Width Inter-connector Busbar Other dimensions, solder composition and solder thickness available on enquiry. 14 SolarSol TM Solar Cable and Components
15 CO-M-JBC Junction Box for PV module (Crystalline) Backside of Crystalline Solar Module Rated Voltage Rated Current Contact Resistance Degree of Protection Rage( ) DC 1000V (TÜV), 600V (UL) 12A (TÜV), 20A (UL) 5 mω IP ~ +85 Properties Diode Vrrm : 40V Lav : 15A, 12A Approval DIN V VDE V (TÜV), UL 1703 (UL) Type Size (W x L x H) Cable Outer Diameter Junction Box for Crystalline Solar Module X 123 X Solar Cable and Components SolarSol TM 15
16 CO-M-JBT Junction Box for PV module (Thin film) Backside of thin film solar module Rated Voltage Rated Current Contact Resistance Degree of Protection Rage( ) Properties Diode Vrrm : 1000V Lav : 10A Approval DIN V VDE V (TÜV), UL 1703 (UL) DC 1000V (TÜV), 600V (UL) 7A (TÜV, UL) 5 mω IP ~ +85 Type Size (W x L x H) Cable Outer Diameter Junction Box for Thin Film Solar Module 53.8 X 78.5 X SolarSol TM Solar Cable and Components
17 CO-CN-PVCNT01 Cable Connector of Locking Type(MC4 Compatible) Interconnection between solar cables Rated Voltage Rated Current Contact Materials Degree of Protection Rage( ) DC 1000V (TÜV), 600V (UL) 22A (Cable O.D. 5.1mm), 30A(Cable O.D.5.8mm) Cu, tin plated PPO (Locking Type) IP ~ + 85 Approval EN 50521(TÜV), UL 1703 (UL) Type Locking Type Male/Female Connector (MC4 Compatible) Locking Type Male/Female Connector (MC4 Compatible) Cable Outer Diameter Cable Outer Diameter (AWG) Solar Cable and Components SolarSol TM 17
18 CO-CN-PVCNT02 Cable Connector of Unlocking Type(MC3 Compatible) Interconnection between solar cables Rated Voltage Rated Current Contact Materials Degree of Protection Rage( ) DC 1000V (TÜV), 600V (UL) 22A (Cable O.D. 5.1mm), 30A(Cable O.D.5.8mm) Cu, tin plated TPV (Unlocking Type) IP ~ + 85 Approval EN 50521(TÜV), UL 1703 (UL) Type Unlocking Type Male/Female Connector (MC3 Compatible) Unlocking Type Male/Female Connector (MC3 Compatible) Cable Outer Diameter Cable Outer Diameter (AWG) SolarSol TM Solar Cable and Components
19 CO-CN-BMFF, CO-CN-BFMM MFF, FMM Branch Interconnection between solar cables Rated Voltage AC/DC 1000 V Rated Current 30 A Contact Cu, Tin plated Materials PC Protection Classification IP 67 Range( ) -40 ~ + 90 MFF : Male Female Female FMM : Female Male Male Type Cable Outer Diameter Cable Outer Diameter (AWG) Male/Female connector Male/Female connector Solar Cable and Components SolarSol TM 19
20 CO-CN-HST Heat Shrinkable Tube Interconnection between cable and connection box, inverter or other electric equipment Rated Voltage 300, 600 V Materials Polyolefin Range( ) -55 ~ +105, 120, SolarSol TM Solar Cable and Components
21 CO-CN-CG Cable Gland Connection between cable and connection box, inverter or other electric equipment Rated Voltage AC/DC 1000 V Rated Current 30 A Contact Cu, Tin plated Materials PC Degree of Protection IP 67 Range( ) - 40 ~ +90 Metric M Size Cable Outer Diameter Dimensions D L M12X ~ M16X ~ M20X1.5 7 ~ M25X1.5 9 ~ M32X ~ M40X ~ M50X ~ M63X ~ Solar Cable and Components SolarSol TM 21
22 SolarSol Power Cable Solar Cable Rated Cross Screening Material of Fiber Reference No. of Core Section Sheath Voltage (mm 2 ) / Armour ( ) Integrated (page) Water-tight P-22.9kV 22.9kV XLPE 1 38 ~ 600 PVC, PO Annealed Cu - 23 (Stranded) P-FCV XLPE 1 ~ ~ 630 FR-PVC Annealed - 24 Cu (Stranded) P-FGV 0.6/1kV PVC ~ Annealed - 26 Cu Finely P-NYY PVC 1 ~ ~ 630 FR-PVC ~ +70 Stranded - 27 Cu Solid P-HIV PVC ~ Annealed /750V Cu P-H07RN-F Rubber 2 ~5 1.5, 2.5, 4, 6, 10 Rubber ~ +60 Cu Wire (HAR bare or tinned) - 30 P-BD Max.1kV O PET, Epoxy 4 - Al housing ~ +130 Cu, Al (Option) 32
23 P-22.9kV 22.9 kv CN/CV-W Cable Connection from solar farm to grid Construction Water-resistant compacted conductor Semiconducting layer for conductor XLPE Semiconducting layer for Neutral wire Sheath FR-PVC Sheath Approx. Ovevall D.C Composition Diameter Thiclcness Thickness Diameter Resistance(20 ) (No./mm) / km 38 * , * , * , * , * , * , * , * , * , * ,500 Nominal Area (mm 2 ) Resistance(70 ) M / km Power Cable SolarSol TM 23
24 P-FCV F-CV Cable (TFR-CV) Main power line for interconnection between module array to inverter Construction Sheath Class 2 (Stranded) Annealed Cu XLPE FR- PVC Rated Voltage (U0/U) Rage( ) AC 600/1 kv ~ / 1kV F-CV (Single Core) Sheath Approx.Ovevall D.C Test Approx. Nominal Area Composition Diameter Thiclcness Thickness Diameter Resistance(20 ) Voltage Weight (mm 2 ) (No./mm) ( /km) (kv) (kg/km) 1.5 7/ / / / / * * * * * * * , * , * , * , * , * , * , * , SolarSol TM Power Cable
25 P-FCV F-CV Cable (TFR-CV) 0.6 / 1kV F-CV (2 Core) Nominal Area Composition (mm 2 ) (No./mm) Thiclcness Sheath Thickness Approx.Ovevall Diameter D.C Resistance(20 ) ( /km) Test Voltage (kv) Approx. Weight (kg/km) Diameter 1.5 7/ / / / / * * * * , * , * , * , * , * , * , * , / 1kV F-CV (3 Core) Nominal Area Composition (mm 2 ) (No./mm) Thiclcness Sheath Thickness Approx.Ovevall Diameter D.C Resistance(20 ) ( /km) Test Voltage (kv) Approx. Weight (kg/km) Diameter 1.5 7/ / / / / * * * , * , * , * , * , * , * , * , * , / 1kV F-CV (4 Core) Nominal Area Composition (mm 2 ) (No./mm) Thiclcness Sheath Thickness Approx.Ovevall Diameter D.C Resistance(20 ) ( /km) Test Voltage (kv) Approx. Weight (kg/km) Diameter 1.5 7/ / / / / * * , * , * , * , * , * , * , * , * , * ,380 Solar Cable and components SolarSol TM 25
26 P-FGV F-GV Cable (TFR-GV) Grounding module array and equipment Construction Class 2 (Stranded) Annealed Cu wire PVC Rated Voltage (U0/U) Rage( ) AC 600/1 kv ~ / 1kV F-GV Approx.Ovevall D.C Test Approx. Nominal Area Composition Diameter Thiclcness Diameter Resistance(20 ) Voltage Weight mm 2 (No./mm) ( /km) (kv) (kg/km) 1.5 7/ / / / / * * * * * * , * , * , * , * , * , * , * , * , SolarSol TM Power Cable
27 P-NYY Cable for Main Power Line Interconnection between connection box and inverter, direct burial Construction Finely Stranded Copper, IEC class 5 PVC Filling Filling compound over the core assembly Sheath Electron beam cross-linked copolymer Rated Voltage (U0/U) 0.6/1.0kV Rage( ) -40 ~ +70 (Fixed), -5 ~ +50 (Flexing) Max. Bending 15 x O.D. (Single Core) Radius 12 x O.D. (Multi Core) RE = Round conductor, single wire RM = Round conductor, multi-wire SM = Sectorial conductor NYY-J No. Cores X Cross Section (mm 2 ) Outer Diameter Approx. Weight (kg/km) 1 X 25 RM X 35 RM X 50 RM X 70 RM X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE X 1.5 RE 26 1,100 3 X 2.5 RE X 2.5 RE X 2.5 RE X 2.5 RE X 2.5 RE X 2.5 RE X 2.5 RE X 2.5 RE Solar Cable and components SolarSol TM 27
28 P-NYY F-GV Cable (TFR-GV) NYY-J NYY-O No. Cores X Cross Section (mm 2 ) Outer Dia. Outer Diameter Copper Weight (kg/km) Approx. Weight (kg/km) (kg/km) 24 X 2.5 RE 26 1, X 2.5 RE 28 1,400 3 X 4 RE X 4 RE X 4 RE X 6 RE X 6 RE X 6 RE X 10 RE X 10 RE X 10 RE X 16 RE X 16 RE 22 1,039 5 X 16 RE 23 1,240 3 X 25 RM / 16 RE 25 1,595 4 X 25.0 RM 27 1,620 3 X 35 SM / 16 RE 27 1,718 4 X 35 SM 27 1,916 3 X 50 SM / 25 SM 31 2,383 4 X 50 SM 31 2,639 3 X 70 SM / 35 SM 33 3,196 4 X 70 SM 35 3,576 3 X 95 SM / 50 SM 38 4,271 4 X 95 SM 40 4,746 3 X 120 SM / 70 SM 41 5,281 4 X 120 SM 43 5,813 3 X 150 SM / 70 SM 46 6,408 4 X 150 SM 48 7,263 3 X 185 SM / 95 SM 50 7,909 4 X 185 SM 53 8,905 3 X 240 SM / 120SM 57 10,162 4 X 240 SM 60 11,430 1 X 10 RE X 16 RE X 25 RE X 35 RE X 50 RM X 70 RM X 95 RM 19 1,132 1 X 120 RM 21 1,405 1 X 150 RM 22 1,710 1 X 185 RM 24 2,086 1 X 240 RM 27 2,669 1 X 300 RM 30 3,305 1 X 500 RM 39 5,400 2 X 1.5 RE X 2.5 RE X 2.5 RE X 4 RE X 4 RE X 6 RE X 6 RE X 10 RE X 10 RE X 16 RE 22 1,039 4 X 25 RM 27 1,620 4 X 35 SM 27 1,916 4 X 50 SM 31 2,639 4 X 70 SM 35 3,576 4 X 95 SM 40 4, SolarSol TM Power Cable
29 P-HIV HIV Cable Power for small equipment in control room Construction Class 1 Solid Annealed Cu wire PVC Rated Voltage (U0/U) Rage( ) AC 450 / 750 V ~ +90 Approx.Ovevall Diameter D.C Test Approx. Nominal Area Thiclcness Minimum Minimum Resistance(20 ) Resistance(20 ) Voltage Weight (mm 2 ) ( / km) (M / km) (kv) (kg / km) , , , , , ,730 Power Cable SolarSol TM 29
30 P-H07RN-F Cable for Main Power Line in Harsh Condition Interconnection between module arrays and connection box in case of harsh condition Construction Sheath Copper wire (HAR bare or tinned) Rubber type EI4 EM2 type rubber Rated AC 450 / 750 V Voltage (U0/U) -25 ~ +60 Rage( ) Max. Bending 6 x O.D. Radius Properties Flame Retardant Oil Resistant No. Cores X Cross Section (mm 2 ) Outer Outer Diameter Dia. Copper Content Weight (kg/km) Approx. Weight Weight (kg/km) H07RN-F U0/U : 450/750V 3 G ~ X ~ G ~ G ~ G ~ G ~ G ~ G ~ G ~ X ~ G ~ G ~ G ~ G ~ G ~ G ~ , G ~ ,650 2 X ~ G ~ G ~ G ~ G ~ G ~ G ~ G ~ SolarSol TM Power Cable
31 P-H07RN-F No. Cores X Cross Section (mm 2 ) Outer Outer Diameter Dia. Copper Content Weight (kg/km) Approx. Weight Weight (kg/km) 3 G ~ G ~ ,060 5 G ~ ,300 3 G ~ ,090 4 G ~ ,345 5 G ~ ,680 4 G ~ ,995 5 G ~ ,200 2,470 3 G ~ ,008 1,900 4 G ~ ,344 2,645 5 G ~ ,680 2,810 4 G ~ ,920 3,635 5 G ~ ,400 4,050 4 G ~ ,688 4,830 4 G ~ ,648 6,320 4 G ~ ,608 6,830 4 G ~ ,760 8,320 4 G ~ ,104 9,800 4 G ~ ,216 12,100 Single core rubber cable H07RN-F U0/U : 450/750V 1 X ~ X ~ X ~ X ~ X ~ X ~ X ~ X ~ X ~ X ~ ,090 1 X ~ ,405 1 X ~ ,152 1,745 1 X ~ ,440 1,887 1 X ~ ,776 2,274 1 X ~ ,304 2,955 1 X ~ ,880 3,479 Power Cable SolarSol TM 31
32 P-BD Bus Duct Aluminum housing coated with paint Optical Fiber(Optional) Optical Filber Bracket(Optical) Interconnection between collected power line to inverter Interconnection between electric equipment in control room Construction Housing Cu, Al PET, Epoxy Al Optical Filber Bracket(Optical) (Copper / Aluminum) Insulator (Class B 130 ) - Ex-Way by EPOXY - Ez-Way by PET - Ef-Way by MICA (1200 ) Rated Voltage 1000V Rage( ) -15 ~ +55 AL CU Ampere (A) Outer Dia. Copper Weight Dimension Weight t (kg/km) A (kg/km) W , , , , ,500 (2) ,200 (2) ,600 (2) ,000 (2) ,000 (3) ,000 (3) , , , , , ,200 (2) ,600 (2) ,000 (2) ,000 (2) ,000 (3) ,500 (3) SolarSol TM Power Cable
33 SolarSol Communication Cable No. of Core Cross Section (mm 2 ) Sheath Screening /Armour Material of Reference (page) C-UTP HDPE, FR-PE FR-PVC, FR-PO - Solid Cu 34 Communication Cable C-HFBT Foam PE PVC Tinned Cu Braid Cu Al/Mylar + Braid + Al/Mylar 35 C-482/485 PE 4 ~ LDPE, PVC - Stranded Tinned Cu 36 C-OF PE 2 ~ PE - Optical fiber 37
34 C-UTP UTP Cable Monitoring climate data (, Humidity, Wind Speed) Monitoring module array, inverter, and connection box (Power Generation, and etc) Construction Sheath Solid Copper HDPE, FR-PE FR-PVC, Low-smoke, Zero-halogen, FR-PO No. of Pairs UTP Category 5 CM/CMR/CMP UTP Category 3 CM Diameter Approx. Ovevall Diameter Approx. Weight (kg / 300m) Packing Method BOX Drum Drum Drum Drum Drum Drum Drum 34 SolarSol TM Communication Cable
35 C-HFBT HFBT Cable Transmitting CCTV video data Construction Internal Externa Sheath Solid copper wire Al/Myler tape (both sides Al foil), tin coated annealed copper braid and Al Mylar tape(single side Al foil) Foamed PE Black PVC 5C-HFBT, 7c-HFBT, 10C-HFBT Product Model (mm 2 ) Inner Outer Condutor Sheath Characteristic Capaciatance Attenuation Diameter Thiclcness Diameter Type Material Construcition Thiclcness Diameter Impedance (nom.) 250Mhz Over (nom.) ( ) (pf/m) 770MHz (db/km) (db/km) 5C-HFBT Solid Wire 1.2 PE * under99 under185 7C-HFBT Solid Wire 1.8 PE * under71 under124 10C-HFBT Solid Wire 2.4 PE * under54 under99 * AL/Mylar+Braid+AL/Myial Communication Cable SolarSol TM 35
36 C-RS 422, 485 RS-422/485 Cable Monitoring module array, connection box, inverter and electrical equipments Construction Screening Sheath Stranded tinned copper PE 100% Al Mylar + Tinned Cu Braid LDPE, PVC No. of Core x Cross Section (mm 2 ) Outer Diameter Copper Weight (kg/km) Weight (kg/km) 4 X X X 2 X X 2 X X 2 X X 2 X X 2 X X 2 X X 2 X X 2 X Other size, No. of core and pair cables available on enquiry. 36 SolarSol TM Communication Cable
37 C-OF For Outdoor Duct Monitoring module arrays and connection boxes in long distance Construction Optical fiber Sheath 2 ~ 24 (Single mode, Multi mode) PE -25 ~ +60 (Operating) Rage( ) -20 ~ +70 (Storage) Specification Telcordia GR-20-CORE IEC / IEC ITU-T G652 Properties RoHS compliance Fiber Crush Load Minimum Bend Radius Nominal Diameter Nominal Weight Maximum Tensile Load Short Term Long Term Loaded Loaded Count (inch) (kg/km) (lb/kft) (N) (N) (N/cm) (N/cm) (inch) (inch) Communication Cable SolarSol TM 37
38 CO-CN-CPA6 Conduit Protection of solar cables Core Material PA 6 Range( ) - 40 to +105 (+150 intermittent) Flammability Rating UL 94 V-2 Halogen free System IP Rating IP69 Nominal Size Length (m) Inner Diameter Outer Diameter Bending Radius SolarSol TM Communication Cable
39 CO-CN-CS Cable Stripping Plier Removing cable insulator Properties For core cross section of 0.75~6 mm 2 cable SolarSol TM CO-CN-CC Cable Crimping Tool Crimping cable and terminal lug Properties For core cross section of 0.5~6 mm 2 cable Communication Cable SolarSol TM 39
40
41
42
43
20 HUBER+SUHNER RADOX SOLAR
All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX
More informationPRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved
Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info
More informationFR-3S Fire Resistant Cables
FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and
More informationBasic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S
ADDISON Flame Retardant Tight Buffered Distribution Optic cables MTA-B-C-D-Y Tight Buffer Coating Glass Yarn Ripcord(optional) PVC Outer Sheath APPLICATION This cables are used for interconnection of distribution
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial
More informationDC Cabling Ready for 1,500 V DC
DC Cabling Ready for 1,500 V DC Perfectly connected MADE IN GERMANY Reduce your LCOE with 1,500V DC architecture What causes PV costs? Since 2010 the PV market has changed a lot. PV module costs have been
More informationCABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue
CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main
More informationLDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.
INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationÖLFLEX CLASSIC 110 CY
Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationVDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications
VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,
More informationUNSHIELDED MULTI CONDUCTOR
PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,
More informationPower & Control Cable IEC
(2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationThe cables you need when you need them
The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you
More informationE R C. R E R C ; ; W T E C
WTEC and its affiliates is an engineering, manufacturing, procurement and construction company dedicated to the alternative energy market. It designs and produces products to move energy from the generation
More informationENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics
ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals
More informationPOLYCAB WIRES PVT. LTD.
Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410
More informationSolar Cable www.bericacavi.com www.fctsecuritycables.com SOLAR CABLE TINNED COPPER Outer sheath Insulation Conductor Conductors: fine wires stranded of tinned copper Cl. 5 CEI EN 60228 Insulation: 2Pfg
More informationDetailed Specifications & Technical Data
Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical
More informationPOLYCAB WIRES PVT. LTD.
POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................
More informationPOLYCAB WIRES PVT. LTD.
Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT
More informationENERGY. Solar Cables
ENERGY Solar Cables Contents TECSUN(PV) PV1-F Cables for Photovoltaics 3 Technical Data 4 Design Features 6 Selection and Ordering Data 6 TECSUN DUO (PV) Cables for Photovoltaics 7 Technical Data 8 Design
More informationCaledonian Fire Resistant Optic Fiber Cables
Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They
More informationfiber optic cable Outdoor Cables
fiber optic cable Outdoor Outdoor Cables CST Armored cables for direct-buried applications Product specifications Outdoor Cables OC 1 CST & FRP Armor Applications Ideal for installation where direct-burial
More informationAmphenol AMPHENOL SOLAR PRODUCTS. Energy Amphenol Industrial
AMPHENOL SOLAR PRODUCTS 1 HELIOS H4 FULL ACCORDING NEC 2008 Although the electrical connectors attached to the ends of the module cables are finger safe when new, if they are opened under load, the dc
More informationOur confession to the solar technology
Our confession to the solar technology The shortage of fossil com - bust ibles worldwide, the adoption of the Renewable-Energy-Bill EEG and finally also the positive atti tude of users and consumers re
More information1.Water proof and dust proof 2.Simple,quick installation 3.compatible with MC4 solar connector 4.competitive price
MC 4 Connector 1.Water proof and dust proof 2.Simple,quick installation 3.compatible with MC4 solar connector 4.competitive price Technical data: Insulation material:pc Rated current:30a Rated voltage:1000v
More informationInsulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black
-I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed
More informationflame Retardant overall screened Instrumentation cables (Multicore)
Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer
More informationAny inquiries, please feel free to contact or Caledonian
Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationTHE WORLD OF LAPP. Products for photovoltaic 2016/17
THE WORLD OF LAPP Products for photovoltaic 2016/17 Legend for icons INDUSTRIES PRODUCT CHARACTERISTICS Automation Suitable for outdoor use Low weight Mechanical and Plant Engineering Good chemical resistance
More informationTechnical attributes
Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,
More informationFlame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)
Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationSolid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816
Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements
PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application
More informationRADOX SOLAR. Edition 2011
RADOX SOLAR Edition 2011 Be energised Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Under
More informationÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.
Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities
Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,
More informationÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V
PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:
More informationRADOX SOLAR. Edition 2014
RADOX SOLAR Edition 2014 Be energised Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Under
More informationÖLFLEX CLASSIC 110 H Info Benefits
Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article
More informationArticle number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}
Description 12x SM G.657.A1 (2x6) The Loose Tube Cable Slim Rodent-Protected () is a non-metallic, loose tube outdoor duct cable, rodent protected, longitudinal water-protected, with high pulling force.
More information600/1000V, PVC Insulated Cables according to IEC
8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)
More information6000 Series Ethernet Buccaneer
Thermo-plastic version Patch Cord Flex Connector - Pur Jacket Cable PXP6037 Mates with PXP6033TP type panel mounting Overmoulded patchcords with IP rated connector Supplied with shielded RJ45 plug Single
More informationFlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E
Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics
ENERGY TECSUN(PV) PV1 F Cables for Photovoltaics Technical Data Electrical Thermal Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / DE TECSUN (PV)
More informationPower & Control Cables
The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.
More informationINFORMATION. Hybrid cables. Description
Description INFORMATION This chapter shows the technical data of the hybrid cables available at SEW EURODRIVE. For assignment of hybrid cables to the products, refer to the respective chapters..1 Description
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V
More informationPVC SHEATH FLAME RETARDANT CABLE TO IEC60332
600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit
More informationCables for Railway Technology
Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual
More information75 OHM COAXIAL CABLE (RG6)
RG6 CABLE (RG6) Drop Cable RG6 UL listed as type CMG for indoor cables. RG-6. 18 AWG copper covered steel with nominal diameter of 0.040 inch (1.02mm). Gas injected foam polyolefin insulation. Nominal
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities
Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More information600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH
More informationFlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable
Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813
More informationis the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.
is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing
More informationCoupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut
Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68
More information0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR
TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE
More informationTelephone Cables Fire Warning Cables
Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More informationNA2XSEKRY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95
More informationBS 6724 Armoured Power Cables, 600/1000V
BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The
More informationEthernet Buccaneer BUCCANEER DATA. bulgin
BUCCANEER FOR DATA bulgin Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationTHERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx
THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology
PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).
More informationPower & Control Cables. U o. /U 0.6/1 kv - IEC
Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4
More informationFISCHER FREEDOM TM SERIES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationNA2XSEKY 3 x (25-300) mm² 3.6/6 kv
NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5
More information300 V TTR KABLOLAR 300 V MULTICORE CABLES H03VV-F H03V2V2-F H03V2V2-F 105 C H03VVH2-F H03V2V2H2-F H03V2V2H2-F 105 C TS 9760 HD 21.5 S3 - VDE 0281-5 HD 21.5 S3 TS HD 21.12 S1 - VDE 0281-12 HD 21.12 S1 TS
More informationPROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics
PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationDNV-GL HH CE RoHS-II conform
Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable
More informationData sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight
More informationEthernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA
IP68 Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains IP68 seal to panel
More informationSUNCLIX Connection technology for photovoltaics
SUNCLIX Connection technology for photovoltaics SUNCLIX The unique connection system for photovoltaics Are you looking for an innovative and reliable connection method for your PV modules, inverters or
More informationN2XSEFGbY 3 x (25-300) mm² 3.6/6 kv
N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0
More informationMining and Petrochemical Tray-Rated Fiber Optic Cables
Features and Benefits Loose tube construction Stable and highly reliable transmission parameters Waterblocking technology Allows efficient and craft-friendly cable preparation Extra tough double jackets
More informationConductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5
Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail
More informationCF270.UL.D.
Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:
More informationINDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS
INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More informationTC-RHH/RHW-2 USE-2 Copper
TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationFlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable
Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationTECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire
TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire A brand of the Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable
More informationIdentification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No
PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined