Water analysis, QC and more:
|
|
- Ann Jones
- 5 years ago
- Views:
Transcription
1 Water analysis, QC and more: photoflex THE REAL MULTI COLORIMETER Standardized and easy-to-use Sturdy and waterproof Sophisticated and versatile
2 Environmental Protection: Fish Farming and Surface Water: Water, Beverage- and Quality Control: Accessories... Monitoring Comprehensive Water Analysis Free Ammonia and CO 2 The real Multi with ph and Turbidity... for Lab and on the Go LabStation for even more comfort LSdata-Software for GLP-compliant data management Programming of user-defined programs AQA: photoflex Check From Ammonia to Zinc: More than 150 programs for routine analysis Test kits for every demand: from high precisely to easy, fast and economic Storage with Identification Number (ID) Datafilter for easy selection of data sets photoflex STD, plus: Electrochemical ph-measurement from ph (± 0.01) for Standard DIN ph-electrodes Automatic Temperature Compensation (ATC) Redox Measurement 1-3 point calibration with calibration interval setting and calibration protocol IR light source acc. to DIN 27027/ISO 7027 photoflex ph, plus: Turbidity measurement range from NTU/FNU providing drinking water accuracy Longterm stable AMCO Clear Standards with ±1% manufacturing accuracy The most versatile colorimeter for field and lab Field Sets: the mobile lab
3 At a glance: Backlit display Intuitive user guidance Test kit measurement range, result, blank value... Working Smart: Robust and waterproof (IP 67) Working faster at your fingertips Simple selection via favorite list Store with Identification number (ID) Orderr. photoflex Instrument (SET) ( ) ( ) ( ) Photometric Measurement Transmission (%T), Absorption, Concentration ph-measurement (±0.01 ph)/ Redox Turbidity Measurement IR acc. DIN /ISO Calibration Intervall /-protocol Programs more than 150 Special programs with ph and Temperature NH 3, CO 2 User-defined programs via LSdata Software Data Sets (with Identification number ID) Field Sets with Accessories optional Optics power saving LED optical Filters: 436, 517, 557, 594, 610, 690 nm Abs reproduceability, < 2 nm wavelength accuracy Cell sizes 16 mm round ( H: mm); 28 mm Batteries 4 AA for approx measurements Interface, Update via Internet RS232 cable AK 540 B (Accessories) LSdata PC Software included in Sets or indivudal package optional Lab use: optional Accessories LabStation with barcode option via Scanner, incl. recharg. batteries and PC software LSdata, cable Recharg. batteries universal power supply optional optional Certificates CE/ETLus/cETL For more detailed information please order free of charge our catalog Lab and Field Instrumentation or visit our web site : (For convenience use our QR code). WTW Wissenschaftlich-Technische Werkstätten GmbH Dr.-Karl-Slevogt-Straße 1 D Weilheim, Germany Phone: Fax: Info.WTW@Xyleminc.com 03/2014 by WTW GmbH US
4 A Strong Team: photoflex Colorimeters & Reagents from A to Z Cell test with lot Reagent test with lot TC Cell test w/o lot TP Powder Pillow test w/o lot TR Reagent test w/o lot Measuring easy and (almost) unlimited: Second to none are the cell tests in 16 mm round vials offering highest precision with easy handling by ready-to-use reagent mix. Reagent test kits with lot certificate combine highest precision with superior cost effectiveness. The powder pillow test kits provide sachets with small pack size and thus are ideal for field monitoring, offering a very good accuracy. For those measuring in the lab, barcode support is given by using the Lab- Station with an external barcode reader. Acid Capacity up to p.3 / K S4, mmol/l mg/l CaCO Aluminium Al mg/l Al TP Al-1 TP mg/l Al Ammonia NH mg / l NH / / mg / l NH TP N -1 TP mg / l NH TC mg / l NH TC mg / l NH with photoflex ph/turb: subject to ph value and temperature; range given for ph 8,5 / 25 C Ammonium N A6 / mg / l N mg/l N mg / l N mg/l N / / mg / l N mg/l N TP N -1 TP mg / l N mg/l N -2 TC mg / l N mg/l N -3 TC mg / l N mg/l N Arsenic mg / l As Cadmium Cd mg / l Cd mg / l Cd Calcium Ca mg / l Ca Carbon dioxide / mg / l CO CO 2 with photoflex ph/turb: subject to ph value and temperature; range given for ph 6,5 / 18,6 C Chlorine Cl mg / l Cl mg / l Cl Chlorine Cl 2 TP Cl-1 TP mg / l Cl 2 free TP Cl-2 TP mg / l Cl 2 free TP Cl-3 TP mg / l Cl 2 total TP Cl-4 TP mg / l Cl 2 total Chlorine Liquid test kit Cl 2 freetotal / fg fg g fg mg / l Cl Chloride Cl mg / l Cl / / mg / l Cl Chlorine dioxide mg/l ClO ClO 2 Chromate Cr mg / l Cr COD C3/ mg/l COD Chemical oxygen mg/l COD demand O mg/l COD Cyanuric acid C4/ mg/l COD mg/l COD mg/l COD mg/l COD TC COD1 TC mg/l COD TC COD2 TC mg/l COD TC COD3 TC mg/l COD COD Chemical mg/l COD oxygen demand mg/l COD Copper Cu mg / l Cu mg / l Mg TP Cu-1 TP mg / l Mn Cyanide CN mg / l CN Cyanuric acid mg/l Cyanuric acid
5 DEHA/Oxygen scavenger TP DEHA-1 TP mg/l DEHA Fluoride F mg / l F Formaldehyde mg/l HCHO HCHO Gold Au mg/l Au Hydrazine N 2 TR N 2 1 TR mg/l N Iron Fe mg / l Fe mg / l Fe / / mg / l Fe TP Fe-1 TP mg / l Fe TP Fe-2 TP mg / l Fe Lead Pb mg / l Pb Magnesium Mg mg / l Mg Manganese Mn / / mg / l Mn mg / l Mn TP Mn-1 TP mg / l Mn TP Mn-2 TP mg / l Mn Molybdenum Mo mg/l Mo mg/l Mo TP Mo-1 TP mg/l Mo TP Mo-2 TP mg/l Mo Nickel Ni mg/l Ni mg/l Ni Nitrat NO mg / l NO mg/l NO mg / l NO mg/l NO mg / l NO mg/l NO TC NO 3-1 TC mg / l NO mg/l NO 3 Nitrit NO 2 N5 / mg / l NO mg/l NO 2 Ozone O / / mg / l NO mg/l NO TP NO2-1 TP mg / l NO TP NO2-3 TP mg/l NO TC NO2-2 TC mg / l NO mg/l NO / / mg/l O Phenol C 6 H 5 OH mg/l C 6 H 5 OH Phosphat PO 4 P6 / mg / l PO mg/l P total mg/l PO 4 P7 / mg / l PO mg/l P total mg/l PO mg / l PO mg/l PO mg/l PO mg/l PO / / mg / l PO mg/l P total mg/l PO Phosphat PO mg/l PO mg/l PO 4 TP PO 4-1 TP mg / l PO mg/l PO 4 TC PO 4-2 TC mg / l PO mg/l PO TC TC PO 4-3 TC PO 4-4 TC mg/l PO mg/l P total mg/l PO 4 Cell test with lot Reagent test with lot TC Cell test w/o lot TP Powder Pillow test w/o lot TR Reagent test w/o lot not suitable for sea water Potassium K mg / l K mg / l K Silicate/ mg / l Si Silicic acid Si mg/l SiO mg/l Si mg/ SiO TP Si-1 TP mg / l Si mg / l SiO 2 TP Si-2 TP mg/l Si mg/l SiO 2 TP Si-3 TP mg/l Si mg/l SiO 2 Silver Ag mg/l Ag Sodium Na mg / l Na Sulfate SO mg / l SO TP SO4-1 TP 0 70 mg / l SO TP SO4-2 TP 2 70 mg / l SO a-ten (anionic) mg/l a-ten n-ten (nonionic) mg/l Triton X Total Nitrogen mg / l N ges N total TC N tot 1 TC mg / l N ges TC N tot 2 TC mg / l N ges Water hardness, d, total hardness mg / l Ca Zinc Zn mg / l Zn mg / l Zn Coloration (reagent free) 436 nm 517 nm 610 nm photoflex Check Testing equipment for AQA For more detailed information please order free of charge our catalog Lab and Field Instrumentation or visit our web site : (For convenience use our QR code). WTW Wissenschaftlich-Technische Werkstätten GmbH Dr.-Karl-Slevogt-Straße 1 D Weilheim, Germany Phone: Fax: Info.WTW@Xyleminc.com All names are registered tradenames or trademarks of Xylem Inc. or one of its subsidiaries. Technical changes reserved WTW GmbH US October 2015
Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 5 I. WATER 1. Potable / Drinking Temperature IS 3025 (Part 9): 1984 (RA 2006) Ambient - 50 C Turbidity IS 3025 (Part 10): 1984 (RA 2006) 1 NTU to 100 NTU Specific Conductivity
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6
Last Amended on - Page 1 of 6 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Quality Monitoring Respirable Suspended Particulate Matter Less than 10µm or PM10 IS:5182 (Part 23):2006 5-1000 µg/m3 Respirable
More informationComparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.
Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing
More informationOperating manual. LabStation LS Flex/430
Operating manual LabStation LS Flex/430 ba75968edfs01 03/2012 Copyright Weilheim 2012, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH,
More informationEcosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date
Ecosteps Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh Last Amended on - Page 1 of 10 Specific Performed Method Specification Range of ing / At I. WATER 1. Potable Water/ Domestic Bore Water/ De-mineralized
More informationTintometer -Group. Comparator Highlights. The system for colorimetric water analysis
Tintometer -Group Highlights More than 400 different test discs are available Compensation for coloured and turbid samples Guaranteed constancy of the coloured glass standards Integrated prism The system
More informationCHECKIT Comparator. with continuous colour scales. Pool & Spa Water Testing - January 2017
with continuous colour scales 16 www.lovibond.com Pool & Spa Water Testing - January 2017 Front view of the with cells Test Kit in carrying case, ready to use Plastic cells, frosted on two sides, volume
More informationION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION
ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION WATER QUALITY PRODUCTS You can t manage what you can t measure. The importance of measurement is very well recognized by the industry. However, lack of
More informationVHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis
VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis Metallo-Organic Standards from VHG Labs VHG Labs has been a provider of quality analytical products and services for over 25 years.
More informationSAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9
Acidity SM 2310B 14 days - - 100 ml - - 250mL P None Alkalinity (as CaCO 3) SM 2320B 14 days NS 5 100 ml - - 250mL P None Ammonia Nitrogen SM 4500NH3-D 28 days - - 100 ml - - 250mL P H 2 SO 4 Asbestos
More informationRadionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x
Ac-225 Actinium(89) 0.6 16.2 1x10-2 0.270 2.1x10 3 5.8x10 4 Ac-227 40 1080 2x10-5 5.41x10-4 2.7 7.2x10 1 Ac-228 0.6 16.2 0.4 10.8 8.4x10 4 2.2x10 6 Ag-105 Silver(47) 2 54.1 2 54.1 1.1x10 3 3.0x10 4 Ag-108m
More informationortable ph, Conductivity & DO2 Meters
ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500
More informationTitrette. class A precision. 10 ml. New. size. The next generation Digital Burette!
The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10, 25, and 50 sizes, you can titrate quickly and reliably
More informationTitrette. class A precision. The next generation Digital Burette!
The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10 ml, 25 ml, and 50 ml sizes, you can titrate quickly and
More informationTitrette. class A precision. The next generation Digital Burette!
The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in
More informationPlate Heat Exchangers
Plate Heat Exchangers General Plate heat exchangers are used wherever thermal energy (heat) has to be transferred from one fl uid to another. The advantage is that they can maintain the fl uid temperature
More informationMPP 910 IDS MPP 930 IDS
Operating manual MPP 910 IDS MPP 930 IDS MPP 910 IDS MPP 930 IDS (Sample figures. Actual equipment depending on scope of delivery and selected options) Modular multi-parameter probe with depth measurement
More information4 A village survey: Mandari, Lakshmipur
115 4 A village survey: Mandari, A rapid hydrochemical survey of the mouza (village) of Mandari, District was carried out during November 1999. Arsenic in the survey was measured in a various field laboratories
More informationN E W! The next generation Digital Burette.
N E W! Bottle-top Burette Easy dropwise titration, a compact, highprecision design, replaceable piston/cylinder assembly and an optional PC interface these are just some of the features of this successor
More informationMiniLab EL Series for High Performance Engine Development and Maintenance
MiniLab EL Series for High Performance Engine Development and Maintenance Optimize performance output Detect problems early Ensure safety in operation Engine Oil Analysis: A Reliable Technique for Engine
More informationTRACE ELEMENTS IN URINE. Event #3, 2012
TRACE ELEMENTS IN URINE Event #3, 202 November 30 th, 202 Event #3, 202 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent. Urine was collected
More informationTRACE ELEMENTS IN URINE
TRACE ELEMENTS IN URINE Proficiency Test Report Event #1, 014 March 4 th, 014 Event #1, 014 Urine Arsenic The source of the test materials is human urine obtained from donor volunteers with informed consent.
More informationMONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION
COLD CORROSION MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION UNIMARINE MARINE ENGINES CYLINDERS SCRAPE-DOWN OIL ANALYSIS (CSDOA) FOCUS ON PREVENTIVE MAINTENANCE UniMarine provides high
More informationThe Measure of all Things. Volumetric Solutions from Merck
The Measure of all Things Volumetric Solutions from Merck Titration is the oldest but still the most precise procedure in chemical analysis. However, such precise analyses require accurately adjusted volumetric
More informationMiniLab EL Series for High Performance Engine Development and Maintenance
MiniLab EL Series for High Performance Engine Development and Maintenance Optimize performance output Detect problems early Ensure safety in operation Engine Oil Analysis: A Reliable Technique for Engine
More informationUIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.
DATE SAMPLED 16-May-15 15-Apr-15 15-Mar-15 03-Mar-15 15-Feb-15 15-Jan-15 DATE RECEIVED 22-May-15 23-Apr-15 23-Mar-15 09-Mar-15 20-Feb-15 22-Jan-15 DATE REPORTED 26-May-15 24-Apr-15 24-Mar-15 11-Mar-15
More informationAnalysis of Petroleum Samples Using the Teledyne Leeman Labs
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 ICP Petroleum Analysis of Petroleum Samples Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications
More information10.6 Schedule of Accreditation
Testing Laboratory is accredited by the GCC Accreditation Center () in accordance with the recognised International Standard, General requirements for the competence of testing and calibration laboratories
More informationAPPENDIX D WATER QUALITY DATA
APPENDIX D WATER QUALITY DATA Mr. John Keating August 9, 2002 Page 2/8 SW-4 and at the settling pond near the bulk extraction area. In addition, total and faecal coliform bacteria samples are collected
More informationSERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck
Antriebstechnik Drive Technology \\ Antriebsautomatisierung Drive Automation \ System \ Systemintegration Integration \ Services \ Services Condition Monitoring Service Oil Check Condition Monitoring Lubricant
More informationAnalysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES
Application Note AN1705 Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES John Condon, Applications Chemist and Bruce MacAllister, Applications Chemist; Teledyne Leeman Labs Page
More informationTest papers Test strips
Dip & Read Tests Test papers Test strips Accurate Rapid Easy Dip & Read Tests for more than 40 substances ph indicators semi-quantitative tests qualitative tests MACHEREY-NAGEL Welcome MACHEREY-NAGEL is
More informationElemental Analysis Advanced
better analysis counts Elemental Analysis Advanced Rapid sulfur measurement plus 12 elements from P to Zn. ASTM D4294 ISO 8754 IP 336 Advanced Software and Data Management Petra offers the latest software
More informationStamolys CA71AM. Technical Information
Technical Information Stamolys CA71AM Ammonium analyzer Compact photometric analysis system for the ammonium measurement in sewage treatment plants, in drinking water and in industrial water treatments
More information224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE
SCP SCIENCE 211 conostan - oil analysis standards SCP SCIENCE is proud to present CONOSTAN - the world s most trusted name in Oil Standards, whose industryleading position is the result of a uniquely superior
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationProduct data sheet VAPODEST 50s / 50s carousel
VAPODEST 50S / 50S CAROUSEL - Systems in comparison Standard configuration VAP50s VAP50s carousel Automatic addition H 3 BO 3 Automatic addition H 2 O Automatic addition NaOH Programmable reaction time
More informationENGINEERED LUBRICANTS CO.
ENGINEERED LUBRICANTS CO. LABORATORY FEE SCHEDULE Effective August 1, 2017 Page 1 of 5 Please send in SDS with samples. If you do not have an SDS please give a generic make-up of the product. (If we do
More information2-July-2016 Chemsheets A Page 1
www.chemsheets.co.uk 2-July-2016 Chemsheets A2 1076 Page 1 TASK 1 Oxidation states 1) Calculate the oxidation state of the stated element in the following species: a) Fe in Fe 0 FeCl 3 +3 FeCl 2 +2 K 2FeO
More informationProduct data sheet VAPODEST 50s / 50s carousel
VAPODEST 50S / 50S CAROUSEL - Systems in comparison Standard configuration VAP50s VAP50s carousel Automatic addition H 3 BO 3 Automatic addition H 2 O Automatic addition NaOH Programmable reaction time
More informationlubricants analysis. complete solutions for your lab. Lubricants Analysis
Lubricants Analysis lubricants analysis. complete solutions for your lab. PerkinElmer capabilities for lubricants analysis. The analysis of lubricants for conformity and process control has always been
More informationMeasuring Cells for free chlorine, chlorine dioxide, ozone
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationVariation Notice with introductory note
Variation Notice with introductory note Pollution Prevention and Control Regulations 2000 Dudley Energy from Waste Facility MES Environmental Ltd Lister Road Dudley West Midlands DY2 8JT. Variation Notice
More informationDiscipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013.
Last Amended on - Page 1 of 7 I. FOOD & AGRICULTURAL PRODUCTS 1. Food Grains Moisture AOAC (19 th Eddition): 2012, 930.15 Total Ash AOAC (19 th Eddition): 2012, 923.03 Protein AOAC (19 th Eddition): 2012,
More informationProduct data sheet VAPODEST
VAPODEST all systems in comparison - standard configuration Multi Touch Sensitive Screen 7 VAP 200 VAP 300 VAP 400 VAP 450 without titrator VAP 450 with titrator Programmable addition H 3 BO 3 Programmable
More informationTo the participants of AQS Baden-Württemberg Dear Madam or Sir,
AQS Baden-Württemberg To the participants of AQS Baden-Württemberg Dr. Frank Baumeister, Dr. Michael Koch, Mandy Wünsche Bandtäle 2 70569 Stuttgart GERMANY T +49 711 685-65446 F +49 711 685-63769 info@aqsbw.de
More information1 Alloy specification of standard sacrificial anodes BOLT-ON ANODES / DISC ANODES
Page: CONTENTS: 1 Alloy specification of standard sacrificial anodes 2 Use of zinc or aluminium anodes 3 Use of sacrificial anodes in tanks HULL ANODES 4 23 Aluminium hull anodes 24 40 Zinc hull anodes
More informationIn-Line Methods List for Automated Ion Analyzers. Flow Injection Analysis
In-Line Methods List for Automated Ion Analyzers Flow Injection Analysis 19 January 2018 1 In-line Modules: Method Number Analyte Lamp/Tubing Heater/tubing 10-107-06-6-A Ammonia Not used 850cm Tefzel
More informationSensoLyt 700 SensoLyt 700 SW
Operating manual SensoLyt 700 SensoLyt 700 SW SensoLyt 700 SensoLyt 700 SW ph/orp armature with impedance converter and temperature sensor ba15307e04 12/2005 SensoLyt 700 (SW) Accuracy when going to press
More informationCommitting to the future. The digital manifold testo 550, ideal for all measurement work on refrigeration systems and heat pumps
Committing to the future The digital manifold testo 550, ideal for all measurement work on refrigeration systems and heat pumps The new digital manifold testo 550 offers an unbeatable proce/performance
More informationThe ML-T Balance Line Reliable results Easy operation Compact and convenient. Big Features Go Compact Worry-free Weighing
ML-T Balances The ML-T Balance Line Reliable results Easy operation Compact and convenient Big Features Go Compact Worry-free Weighing Reliable Results ML-T Balances Results You Can Rely On With ever-increasing
More informationPhysico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents
Current World Environment Vol. 7(1), 125-131 (2012) Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents DHANANJAY DWIVEDI 1 and
More informationBlade Fuses - Illuminated Mini Blade
Photo Fuse Features: The photo fuse is designed for the automobile and electrical industry. It has become the original equipment circuit protection standard for automobiles, trucks and low power system.
More informationReport On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test
Report On Evaluation Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Nonreference oil) and shall not be used for multiple test acceptance
More informationCongratulations, Dorothy!
Congratulations, Dorothy! Battery Overview Steve Garland Kyle Jamieson Outline Why is this important? Brief history of batteries Basic chemistry Battery types and characteristics Case study: ThinkPad battery
More informationLaboratory Method Evaluation Report GBRA, August 2013
Introduction Laboratory Method Evaluation Report GBRA, August 2013 The following report outlines information collected under Task 4.1 of Objective 4: Laboratory Method Evaluation of Agreement 582 12 20495,
More informationApplication Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.
Chemical Compatibility Chart 6 Stainless Acetic Acid Acetone Acetylene Acidic Mine Water Acrylonitrile Ammonium Chloride Ammonium Hydroxide Ammonium Sulfate Ammonium Thio-Sulfate Anhydrous Ammonia Anhydrous
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE
More informationCeramics for pyrometers, furnace construction & laboratory ware. Schunk Ingenieurkeramik
Ceramics for pyrometers, furnace construction & laboratory ware Schunk Ingenieurkeramik Advantages High dimensional tolerance Very good thermal shock resistance Chemical corrosion resistance High heat
More informationConductivity Measurement CLM 280
Technical Information TI 347C/07/en/07.03 51511754 Conductivity Measurement CLM 280 Battery-driven pocket meter for conductivity and resistance measurement Application CLM 280 is a compact pocket meter
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11035-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 13.02.2018 to 12.02.2023 Holder of certificate: DMT
More informationX-ray Essentials from XOS Proven Performance
Petroleum Systems Services Corporation PSSC 2789 State Route 9 Malta, NY 12020-4357 phone: 518-581-0189 fax: 518-581-0201 email: pssc@pssc.org X-ray Essentials from XOS Proven Performance Elemental Analysis
More informationVortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1
Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow
More informationCOTTER CORPORATION CANON CITY MILLING FACILITY
CALENDAR YEAR 2004 APPENDIX C Water Quality Monitoring Report COTTER CORPORATION CANON CITY MILLING FACILITY Canon City, Colorado June 30, 2005 COTTER CORPORATION WATER SAMPLING LOCATIONS JUNE 30, 2005
More informationModel 2053 Conductivity Meter Instruction Manual
Model 2053 Conductivity Meter Instruction Manual Printed in U.S.A. 09/2006 Ship Date: Serial Number: Calibrated By: Table of Contents Page 1. Introduction.. 1 2. Shipping Checklist.. 1 3. Specifications...
More informationOIL PT. Scheme Description. Oils and Fuels Analysis Proficiency Testing Scheme
OIL PT Oils and Fuels Analysis Proficiency Testing Scheme Scheme Description LGC Standards Proficiency Testing 1 Chamberhall Business Park Chamberhall Green Bury, BL9 0AP UK. Telephone: +44 (0) 161 762
More informationJUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationCPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement
Technical Information CPM280 ph/orp measurement Battery-driven pocket meter for ph and ORP measurement Application CPM280 is a pocket meter for measuring ph value and ORP. It is suitable for the following
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY SERVICES, PETROTRIN Southern Main Road Pointe-A-Pierre, Trinidad, Trinidad & Tobago Peter Bhim Phone: 868 658 4200 CHEMICAL Valid To: November 30,
More informationApplication for Energy and Fuels
Application for Energy and Fuels Improved Throughput for Wear Metals Analysis by ICP-OES Using Next Generation Sample Introduction Technology Patrick Simmons, Doug Shrader & Phil Lowenstern Agilent Technologies
More informationFlash Point Process Analyzer
Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,
More informationASTM D Determing Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions. Work Order #:
TEL: 831-724-5422 FAX: 831-724-3188 ASTM D 6400 Determing Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions Work Order #: 0020396-01 Report Prepared For: Aseem Das World
More informationDigimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...
- 2-8 Digimar 816 CL The new Height Measuring Instrument Digimar 816 CL. You want to obtain highly accurate measurement results without any complicated procedures? With the Digimar 816 CL you have the
More informationQC CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager
Page: 1 QC CERTIFICATE SD16032427 This report is for 1 Rock sample submitted to our lab in Sudbury, ON, Canada on 4-MAR-2016. The following have access to data associated with this certificate: TOM VANDRUNEN
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSeamless hot rolled tubes and seamless hollow bars
Seamless hot rolled tubes and seamless hollow bars Benteler Distribution Customised steel tube solutions An internationally operating stockholding company of carbon alloy and stainless steel tubes With
More informationCONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)
CONNECTION BULLETIN Vogt Valves Zero Leakage Forged Steel Check Valves Class 800 FCD VVABR1003-00 10/04 (Replaces CB-03) Experience In Motion Zero Leakage, Forged Steel Check Valves: Class 800 Vogt Series
More informationThe Secrets of Pyrotechnic Whistles. Joseph A. Domanico VP Publications / Webmaster Crackerjacks, Inc.
The Secrets of Pyrotechnic Whistles Joseph A. Domanico VP Publications / Webmaster Crackerjacks, Inc. drpyro@home.com Who Was That Masked Man? Crackerjacks, Inc Vice President Publications Webmaster: www.crackerjacks.org
More informationOil secure power and performance
Oil analysis Oil secure power and performance through professional control Oil is the central component of every hydraulic system. When a system fails, oil contamination is usually the cause. Oil is continously
More informationDräger X-am 5100 Single-Gas Detection Device
Dräger X-am 5100 Single-Gas Detection Device For manufacturing petrochemical products, aseptic packing, or handling of rocket fuel: the Dräger X-am 5100 portable single-gas detector guarantees that you
More informationmagnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type
magnetic flow meters Safmag Flanged Type Lining Electrodes Accuracy 25mm to 800mm Natural rubber Neoprene Ebonite Polyurethane PTFE Hastelloy C Monel Titanium Tantalum Conductive rubber 110 / 220 V AC
More informationAdvanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer
Advanced Petrochemical Applications With ICP-OES Tina Harville, Ph.D. Application Engineer Elemental Analysis of Petrochem-Based Solutions Refineries and Petrochemicals Sulfur content of gasoline Acceptance
More informationAccurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre
Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of
More informationl/min mv Aquaculture Innovative solutions for your success
l/min mv mg/l ppm NTU µs/cm C ms/cm ph Aquaculture Innovative solutions for your success Contact Phone: +49 661 6003-0 Email: industry@jumo.net Dear Reader, All over the world more and more fish and crustaceans
More informationAGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.
Page 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Index Aguapure 100 2 Aguapure 200 2 Lara APS 3 P-Pump 4 Aspendose 5 Tank for chemical 6 Tank with mixer 6 Glass Sensor 7 AguaCon 8 Poolsaver Tetra 10 System
More informationDräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger CMS The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip start measurement
More informationLinea - Line. raccordi a compressione compression fittings
5300 Linea - Line raccordi a compressione compression fittings Raccordi a compressione/ Compression fittings SYSTEM FIELDS OF APPLICATION Mainly used in distribution systems for drinking water, sanitary
More informationInstruction Manual. Coating Thickness Gauge. Optionally with Memory
Instruction Manual Coating Thickness Gauge 1500 Optionally with Memory 1 Introduction The QNix 1500 is a part of the product line of non-destructive coating thickness measurement gauges manufactured by
More informationTRACE ELEMENTS IN WHOLE BLOOD. Event #2, 2010
TRACE ELEMENTS IN WHOLE BLOOD Event #2, 200 June 2, 200 Event #2, 200 Whole Blood Arsenic Test materials for arsenic were prepared from caprine (goat) whole blood preserved with K 2 EDTA anticoagulant.
More informationDaily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City
Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City Toshihiro Kuwayama, Chris R. Ruehl, and Michael J. Kleeman* Department of
More informationINTERPRETATION OF USED COOLANT ANALYSIS
RECO-COOL TECHNICAL BULLETIN 0006/12 INTERPRETATION OF USED COOLANT ANALYSIS Testing of coolants in use (whilst still within service) can give a vital indication on the health of the cooling system of
More informationTECHNICAL INFORMATION
PRO-gran: TECHNICAL INFORMATION The ultimate in pitch performance PRO-gran: THE ULTIMATE PITCH INFILL PRO-gran has literally changed the game in high-performance infill for artificial sports pitches. A
More informationBERKELEY SSCX SERIES CENTRIFUGAL PUMPS
BERKELEY SSCX SERIES CENTRIFUGAL PUMPS WWW.BERKELEYPUMPS.COM REMARKABLE RELIABILITY High-head performance and quiet operation join corrosion-resistant dependability with Berkeley SSCX Series centrifugal
More informationthe experience of many
First for Liquid Analysis Industrial liquid process analyzers the experience of many makes us stronger as one liquid analysis Analyze IT ph conductivity dissolved oxygen turbidity silica phosphate hydrazine
More informationProfessional thermometer and food oil monitor
Professional thermometer and food oil monitor according to EN 12830, EN 13485, EN 13486, HACCP 2017 Continuous Temperature Monitoring and Recording EBI 300 USB Data Logger Continuous temperature monitoring
More informationPRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )
CRD 200 Product Manual Page 1 of 18 PRODUCT MANUAL FOR CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N 062983) CRD 200 (2 mm) (P/N 062986) Dionex Corporation, 2006 Document No. 065068 Revision 04 November
More informationThe Role of Chemical Metrology in Transportation Industry
The Role of Chemical Metrology in Transportation Industry Dr Richard Shin Consultant Scientist Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group Health Sciences Authority,
More informationl/min mv Aquaculture Technology Innovative solutions for your success
l/min mv mg/l ppm NTU µs/cm Aquaculture Technology Innovative solutions for your success C ms/cm ph Contact Phone: +49 661 6003-0 Email: industry@jumo.net Dear Reader, All over the world more and more
More informationPCE-CS 300. Crane Scales up to 300 kg ( 661 lb)
300 Crane Scales PCE-HS N Series Crane Scales up to 150 kg ( 330 lb) powered by 3 x AA 1.5 V batteries auto power off (can be deactivated) PEAK and Hold functions / multiple taring animal weighing function
More informationISO INTERNATIONAL STANDARD. Diesel engines NOx reduction agent AUS 32 Part 1: Quality requirements
INTERNATIONAL STANDARD ISO 22241-1 First edition 2006-10-15 Diesel engines NOx reduction agent AUS 32 Part 1: Quality requirements Moteurs diesel Agent AUS 32 de réduction des NOx Partie 1: Exigences de
More information