CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ. Semester 2 Examinations 2008/09. Bachelor of Science in Process Plant Technology
|
|
- Bennett Howard
- 5 years ago
- Views:
Transcription
1 CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 2 Examinations 2008/09 Module Title: Process Plant Services Module Code: MECH8018 School: Mechanical Engineering. Programme Title: Programme Code: Bachelor of Science in Process Plant Technology EPPTE_8_Y4 External Examiner(s): Mr. Neil Kingston; Mr. Joe Phelan Internal Examiner(s): Mr. Willie Bateman (Section B) Mr. John Healy (Section A) Instructions: Duration: Answer any 3 questions. All questions carry equal marks. Answer Section A and Section B in seperate answer books. 2 hours. Sitting: Summer 2009 Requirements for this examination: Attachments to be provided, for student reference, with this exam paper. 1 Steam Pipeline Sizing Chart Pressure Drop Q1 (with paper) 2 CIBSE Table C Velocity press loss factors. Q3,Q4 (with paper) 3 CIBSE Table C4.11, Page Water 75 C Medium Grade Q3 (with paper) Steel. 4 Vapour Pressure V s Water Temperature. Q3 (with paper) 5 CIBSE Table C4.11, Page Water 75 C Medium Grade Q4 (with paper) Steel. 6 Lowara HTE-HTS Series 2 Pole pumps Data Sheet Q4 (with paper) Note to Candidates: Please check the Programme Title and the Module Title to ensure that you have received the correct examination paper. If in doubt please contact an Invigilator. Page 1 of 10
2 Section A Steam & Refrigeration Q1 a) Compare and contrast the construction and operating characteristics of a Fire Tube Boiler with those of a Water Tube Boiler. [5 marks] b) Why is boiler feed water pre-treatment necessary? [5 marks] c) Why does TDS build up inside a steam boiler? What negative effects can high TDS have on boiler operation? How are TDS levels controlled within a steam boiler? [5 marks] d) Steam is generated at 10 Bar g pressure inside the boiler house. A new process 65m from the boiler house required 5000 kg/h at a minimum supply pressure of 9.0 bar g. Using the steam pipe sizing chart provided suggest the most suitable pipe diameter and calculate the actual pressure available at the point of use. NB design for a maximum pressure drop of 0.1 Bar / 100m. Reference :- [5 marks] Steam Pipeline Sizing Chart Pressure Drop Q1 (with paper) Q2 a). Describe with the aid of a neat sketch a typical refrigeration circuit. Label the four major components. Indicate relative pressures and liquid / gas phases after each of the four major components. [6 marks] b) Where does flash gas occur and how does it effect the fridge cycle? [4 marks] c) Draw a neat labelled sketch of a Split Unit air conditioning system, capable of heating and cooling the air conditioned space, when it is operating in cooling mode. [6 marks] d) Give a brief explanation of each of the following terms in relation to a cooling tower. Induced draught. Drift. Approach. Range. [4 marks] Page 2 of 10
3 Section B Pipe work systems. Q3 The following diagram shows a reactor vessel working under vacuum. Determine if the pump shown will cavitate under the operating conditions shown. [20 marks] Water 80 Deg PG Pressure Gauge Reading 0.5 Bar g vacuum 10.5 m 8.0 m 1.0 m Steel Pipe connecting vessel to pump Welded mild steel elbows Pump Details Q=10 cubic m/h NPSHr = 2.0m 1.0 m 3.0 m Reference 2 CIBSE Table C Velocity press loss factors. Q3 (with paper) 3 CIBSE Table C4.11, Page Water 75 C Medium Grade Steel. Q3 (with paper) 4 Vapour Pressure V s Water Temperature. Q3 (with paper) Q4 A Cleaning In Place (CIP) pipe work system is shown on the next page. Pump and pipe work sizing required for transfer of l/h of water at 75 Deg C to one of three points on T1003, T2002 or T3007. Only one route enable at any one time. Use CIBSE Charts for steel pipe and fittings. Use all welded joints. Page 3 of 10
4 NOTES 0,4 m 2,2 m Stainless Steel Pipe work on all pipe runs. No CIBSE Charts for SS. Use CIBSE Charts for Mild Steel i.e. assume mild steel pipe work on all pipe runs also welded mild steel elbows All valves are actuated Diaphragm valves w/d = 1.0. For CIBSE Table C4.36. CIP nozzles T1003, T2002 residual pressure of 3 bar at inlet to nozzle. CIP spray ball T3007 residual pressure of 1 bar at inlet to spay ball Only one route in use at any one time i.e from pump to one of A. T1003 CIP nozzle. B. T2002 CIP nozzle. C. T3007 Spray Ball. Pumped Volume Q=90,000 l/h Water at 75 Deg C To facilitate agressive washing of pipes + PHE use a target water flow of 3m/s for CIP systems. Tank 3007 CIP spray ball residual press of 1 bar at inlet to nozzle. 3rd Floor Tank nd Floor Tank st Floor Tank m 0,4 m Water at 10 Deg C Tank G100 Ground Floor 0,4 m Tank 1003 CIP nozzle residual pressure of 3 bar at inlet to nozzle. 1 m Tank 2002 CIP nozzle residual press of 3 bar at inlet to nozzle. 4,2 m Cond Outlet 3,2 m P.H.E dp 1.1 Bar 1 m Steam Inlet Floor Drain 2,7 m 3 m 3 m CIP SYSTEM PIPE SIZING EXERCISE a) Estimate which route will be the index run. Without completing detailed calculations use the combined pressured drops associated with straight pipe, fittings, static head and residual head to estimate which run will be the index run. [6 marks] b) Establish the pipe diameter, pl and le for the index run. [4 marks] c) Specify overall flow and pressure requirements for the pump. [8 marks] d) Select a suitable pump from the Lowara pump data sheet attached. [2 marks] 3 CIBSE Table C Velocity press loss factors. Q4 (with paper) 5 CIBSE Table C4.11, Page Water 75 C Medium Grade Steel. Q4 (with paper) 6 Lowara HTE-HTS Series 2 Pole pumps Data Sheet Q4 (with paper) Page 4 of 10
5 Page 5 of 10
6 Page 6 of 10
7 Page 7 of 10
8 Page 8 of 10
9 Page 9 of 10
10 Page 10 of 10
1. (a) If a large power generating station is operating with steam at 16,000 kpa and 500 and exhausting to a condenser at, 37.6 mm mercury absolute;
Sample Questions REVISED SECOND CLASS PARTS B1, B2, AND B3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations, they are not intended as study
More informationTRINITY COLLEGE DUBLIN THE UNIVERSITY OF DUBLIN. Faculty of Engineering, Mathematics and Science. School of Computer Science and Statistics
ST7003-1 TRINITY COLLEGE DUBLIN THE UNIVERSITY OF DUBLIN Faculty of Engineering, Mathematics and Science School of Computer Science and Statistics Postgraduate Certificate in Statistics Hilary Term 2015
More informationPHYA5/2C. General Certificate of Education Advanced Level Examination June Section B. Monday 18 June am to am (JUN12PHYA52C01)
Centre Number Surname Candidate Number For Examinerʼs Use Other Names Candidate Signature Examinerʼs Initials General Certificate of Education Advanced Level Examination June 2012 Question 1 2 Mark Physics
More informationDEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET
I-736 Pg. 1 of 10 Summary The 258BD-200C Drain Master is designed to feed chemicals into drains and grease traps to break up grease, detergent buildup and eliminate odors. The 258BT-200C Trash Master is
More informationHours / 100 Marks Seat No.
17610 16172 4 Hours / 100 Seat No. Instructions (1) All Questions are Compulsory. (2) Answer each next main Question on a new page. (3) Illustrate your answers with neat sketches wherever necessary. (4)
More informationSIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) QUESTION BANK UNIT I I.C ENGINES
SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR UNIT I I.C ENGINES 1 (a) Explain any six types of classification of Internal Combustion engines. (6M) (b) With a neat sketch explain any three
More informationSpare Parts List - DUO 500 & DUO 2
Spare Parts List - DUO 00 & DUO 2 Issue Date 03//200 Part No. 930.000 Issue B MD - 200 Water Inlet -2 Water Drainage 3-4 Wash Pump -6 Bottom Washing / Rinsing System 7-8 Top Washing / Rinsing System DUO
More informationSET - 1 II B. Tech II Semester Regular/Supplementary Examinations, April/May-2017 THERMAL ENGINEERING-I (Mechanical Engineering) Time: 3 hours Max. Marks: 70 Note: 1. Question Paper consists of two parts
More information2013 THERMAL ENGINEERING-I
SET - 1 II B. Tech II Semester, Regular Examinations, April/May 2013 THERMAL ENGINEERING-I (Com. to ME, AME) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions carry Equal Marks ~~~~~~~~~~~~~~~~~~~~~~~~
More informationInstruction Manual for UPPPU
Instruction Manual for UPPPU Contents 1. Product Overview 2. Operations 3. Installation & Commissioning Instructions 4. Bill of Material 5. Maintenance and Troubleshooting 6. Storage 1.Product Overview:-
More informationWINTER 14 EXAMINATION
WINTER 14 EXAMINATION Subject Code: 17413(EME) Model Answer Important Instructions to examiners: 1) The answers should be examined by key words and not as word-to-word as given in the model answer scheme.
More information05 Marks (c) Sketch and explain Lancashire Boiler.
Model question paper No.1 1. Answer any FIVE full questions choosing at least two questions from part A & two questions from part B 2. Use of steam tables is permitted 1. (a) Discuss briefly the different
More information(a) then mean effective pressure and the indicated power for each end ; (b) the total indicated power : [16]
Code No: R05220304 Set No. 1 II B.Tech II Semester Regular Examinations, Apr/May 2007 THERMAL ENGINEERING-I ( Common to Mechanical Engineering and Automobile Engineering) Time: 3 hours Max Marks: 80 Answer
More informationGOVERNMENT ENGINEERING COLLEGE, GODHRA
Practical No. - 1 To understand construction and working of various types of Steam boilers. 1) What is the function of Steam boiler? And what are factors should be considered while selecting a boiler?
More informationSQA Advanced Unit specification: general information
SQA Advanced Unit specification: general information Unit title: Electrical Machine Principles Unit code: HT83 47 Superclass: XJ Publication date: August 2017 Source: Scottish Qualifications Authority
More informationCLASSIFIED 5 MAGNETISM ELECTROMAGNETIC INDUCTION GENERATOR MOTOR - TRANSFORMER. Mr. Hussam Samir
CLASSIFIED 5 MAGNETISM ELECTROMAGNETIC INDUCTION GENERATOR MOTOR - TRANSFORMER Mr. Hussam Samir EXAMINATION QUESTIONS (5) 1. A wire perpendicular to the page carries an electric current in a direction
More informationPressure degassing systems
Pressure degassing systems A degassing system consists of several components: Degassing unit Feedwater tank Instrumentation and control technology Steel structures, platforms and ladders Exhaust vapours
More informationŒ æ fl : GΔ»ÊflMmÈ A±È BMf æ fl MVÈ
CCE RR UN-REVISED B O %lo ÆË v ÃO y Æ fio» flms ÿ,» fl Ê«fiÀ M, ÊMV fl 560 003 KARNATAKA SECONDARY EDUCATION EXAMINATION BOARD, MALLESWARAM, BANGALORE 560 003 G È.G È.G È.. Æ fioê, d È 2018 S. S. L. C.
More informationProgramme area 4a. Fluid Energy Machines
Programme area 4a Fluid Energy 136 Contents: Fundamentals of Fluid Mechanics 138 Thermodynamics 140 Mechanics / Other 142 Power Engines Hydroturbines Pelton...143 Francis...144 others...145 Steam Turbines...146
More informationMIE243 Computer Aided Design I Design Example 1. Problem Your goal is to design a commercial clothes dryer.
Design Example 1 Problem Your goal is to design a commercial clothes dryer. In general, this machine is expected to be able to perform all of the following basic functions: Machine is to be front-loading,
More informationOperation Manual Cobra 1 Automatic Spray Gun
SB-E-2-CBA1 ISS.06 Operation Manual Cobra 1 Automatic Spray Gun E P 1 12 1 Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this
More informationPRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES
WATER METERS VALVES & COCKS PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES FILTER, REGULATOR & LUBRICATORS W IKA V I INSTRUMENTS
More informationSB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun
EN SB-E-2-CBA1 ISS.13 Operation Manual Cobra 1 Automatic Spray Gun Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this equipment
More informationMulti-port Diaphragm Valve, Forged stainless steel body
Fully machined from SS 316L bar-stock no welded components Increased security no internal fabrication welds Reduced dead leg based on orientation Greater structural integrity Fewer fittings, welds and
More informationSCHOOL OF COMPUTING, ENGINEERING AND MATHEMATICS SEMESTER 2 EXAMINATIONS 2013/2014 ME110. Aircraft and Automotive Systems
s SCHOOL OF COMPUTING, ENGINEERING AND MATHEMATICS SEMESTER 2 EXAMINATIONS 2013/2014 ME110 Aircraft and Automotive Systems Time allowed: TWO hours Answer TWO questions from THREE in Section A and TWO questions
More informationThe figure 269J is a double seal mix-proof piston valve, used for product isolation, where safe separation of process and C.I.P. fluids is required.
The figure 269J is a double seal mix-proof piston valve, used for product isolation, where safe separation of process and C.I.P. fluids is required. Features Product contact parts manufactured from high
More informationSpare parts list GREENSTAR CAMRAY. Burner 24/04/
Spare parts list 620620260 GREENSTAR CAMRAY 3 1 8 6 2 9 Burner 24/04/2009 620620260 1 24/04/2009 620620260 2 24/04/2009 620620260 3 Spare parts list 1 Cabinet Assembly rawing Heatslave 12/14 24/04/2009
More informationDEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS
I. PARTS: A. 1 pc. Cyclone Portable Injector B. 1 pc. Foot Strainer & 1/4" I.D. Tubing. C. 1 pc. Ceramic Weight. D. 1 pc. Instruction Sheet D. 2 pc. 3 hose w/ female x female GHT fittings on both ends
More information'' ''' '' ''' Code No: R R16 SET - 1
Code No: R161232 R16 SET - 1 1. a) List the Primary requirements of a Steam Boiler. (2M) b) What are the distinguishing features between a Casting and a Pattern? (2M) c) Define (i) Brake Power; (ii) Indicated
More informationAURORA FILTERS. - S 316L Stainless Steel AF-LD C C22 Hastelloy AF-PC-001/2/3/4/5 Flange Type Designation Code
49 Passmore Ave., Toronto, ON, Canada TF 1-888-368-8884 P 416-299-3311 F 416-299-3387 www.aurorafilters.com AURORA FILTERS Introduction AURORA FILTERS has developed a line of portable Filter Systems that
More informationF269B+ HYGIENIC BALANCED DOUBLE SEAL VALVES REVERSIBLE ACTUATOR TYPE PENTAIR HYGIENIC PROCESS VALVES (FORMERLY KEYSTONE)
PENTAIR HYGIENIC PROCESS VALVES (FORMERLY KEYSTONE) F269B+ HYGIENIC BALANCED DOUBLE SEAL VALVES REVERSIBLE ACTUATOR TYPE FOOD & BEVERAGE PROCESS SOLUTIONS PROCESS VALVE TECHNOLOGY PENTAIR HYGIENIC PROCESS
More informationCambridge International Examinations Cambridge International General Certificate of Secondary Education
Cambridge International Examinations Cambridge International General Certificate of Secondary Education *7100832055* DESIGN AND TECHNOLOGY 0445/41 Paper 4 Systems and Control October/November 2017 1 hour
More information2. Discuss the effects of the following operating variables on detonation
Code No: RR220303 Set No. 1 II B.Tech II Semester Regular Examinations, Apr/May 2006 THERMAL ENGINEERING-I ( Common to Mechanical Engineering and Automobile Engineering) Time: 3 hours Max Marks: 80 Answer
More informationLevel 1 Physics, 2017
90937 909370 1SUPERVISOR S Level 1 Physics, 2017 90937 Demonstrate understanding of aspects of electricity and magnetism 9.30 a.m. Tuesday 28 November 2017 Credits: Four Achievement Achievement with Merit
More informationTECHNICAL INFORMATION F25 AS LT3 12/2011 / B 1
F25 AS LT3 1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 25 Kg 55 60 Lbs BASKET Diameter 1000 mm 39.4 inches Depth 640 mm 25.2 inches Volume 500 Lt 14.1 cu.ft Wash speed 20 50 rpm Extract
More informationSTEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE
STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE Benefits Savings of up to US$ 200.000 per year in maintenance costs Production gains due to superior stability of the temperature control Operational
More informationJUNE 2017 Level 3 Advanced Technical Extended Diploma in Land-based Engineering Level 3 Land-based Engineering Theory Exam (1)
*01715150617* 0171-515 JUNE 2017 Level 3 Advanced Technical Extended Diploma in Land-based Engineering Level 3 Land-based Engineering Theory Exam (1) If provided, stick your candidate barcode label here.
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More informationVAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationCROSBY STYLE JB PRESSURE RELIEF VALVE
A large orifice pressure relief valve engineered to provide high quality, dependable overpressure protection for air, gas, vapor and steam applications FEATURES Ten size product range is the broadest available.
More informationHeavy Duty Que - Temp Desuperheater Model: 13 / 23
Narvik covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry and
More informationNARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64
NARVIK-YARWAY Narvik-Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp &
More information2014 ELECTRICAL TECHNOLOGY
SET - 1 II B. Tech I Semester Regular Examinations, March 2014 ELECTRICAL TECHNOLOGY (Com. to ECE, EIE, BME) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions carry Equal Marks ~~~~~~~~~~~~~~~~~~~~~~~~~~
More informationTECHNICAL INFORMATION HXL 8015 S 11/2011 / 730-C 1
1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 15 Kg 35 Lbs BASKET Diameter 800 mm 31.5 inches Depth 560 mm 22 inches Volume 285 Lt 10.1 cu.ft Wash speed 20 55 rpm Extract speed 300 500 rpm
More informationMODEL CMA-180UC PARTS MANUAL Rev 1.19
MODEL CMA-180UC PARTS MANUAL Rev 1.19 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS
More informationComponent 5 - Physics: Energy, forces and the structure of matter
SPECIMEN MATERIAL Please write clearly, in block capitals. Centre number Candidate number Surname Forename(s) Candidate signature ELC SCIENCE 5960 Externally-Set Assignment Marks Component 5 - Physics:
More informationYARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp and paper industry and
More informationKWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology
KWT GALLEY WATER WASH HOOD With supply air and Capture Jet technology APPLICATIONS Halton KWT is a galley water wash hood for use in marine & offshore applications. The highly efficient KWT hood uses Halton
More informationUNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education
UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education *8019038925* PHYSICS 0625/03 Paper 3 Extended October/November 2007 1 hour 15 minutes Candidates
More informationBASIC CIVIL & MECHANICAL ENGINEERING
SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2000 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI 621 105 DEPARTMENT OF MECHANICAL ENGINEERING FS81504 BASIC CIVIL & MECHANICAL
More information78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves
LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves Featuring High Resistance Multiple Stage LINCOLNLOG Trim Angle Configuration 78200 Globe Configuration 18200 Specification Data CP6020 10/97
More informationYARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER
Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp and paper industry and
More informationPAPER 2 THEORY QUESTIONS
PAPER 2 THEORY QUESTIONS 1 A plastic rod is rubbed with a cloth and becomes negatively charged. (a) Explain how the rod becomes negatively charged when rubbed with a cloth... [2] (b) An uncharged metal-coated
More informationDESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS
DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil
More informationGraspIT AQA GCSE Magnetism and Electromagnetism - Questions
A. Permanent and Induced Magnetism, Magnetic Forces and Fields 1. The following question is about magnets. a. Iron is a magnetic material. Name two other magnetic elements. (2) b. Describe the effect a
More informationSELF-CLEANING FILTER
SELF-CLEANING FILTER CT0126.0_00 UK November 2008 PRODUCTION RANGE Connections Standard Mesh [μm] Size Code Kv [m³/h] THREADED FF UNI-EN-ISO 228 100 3/8 126.03.10 1,80 1/2 126.04.10 3,10 3/4 126.05.10
More informationMODEL NO. UTL-60-7
5301400 MODEL NO. UTL-60-7 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS ASSEMBLY The sprayer is fully assembled at the factory. The only assembly necessary is to thread
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 40 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 35.4 inches 21 gal 90 rpm 12 50 rpm 300 540 inches
More informationSingle-phase Coolant Flow and Heat Transfer
22.06 ENGINEERING OF NUCLEAR SYSTEMS - Fall 2010 Problem Set 5 Single-phase Coolant Flow and Heat Transfer 1) Hydraulic Analysis of the Emergency Core Spray System in a BWR The emergency spray system of
More informationLetter Figures Words SYSTEMS ENGINEERING. Written examination. Monday 19 November 2012
Victorian Certificate of Education 2012 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words SYSTEMS ENGINEERING Written examination Monday 19 November 2012 Reading time: 9.00
More information1103 Per 9: Simple Machines-Levers
Name Section 1103 Per 9: Simple Machines-Levers 9.1 How do Levers Work? 1) Fulcrums and forces a) Place a meter stick on the plastic tube with the 50 cm mark directly above the tube. Place a 5 newton weight
More informationOTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE
OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE THERMOLIER UNIT HEATERS TRENCH HEATING DADO HEATING RAIL HEAT EXCHANGERS GILLED TUBING RADIANT STRIP BLAST COOLERS RADIANT PANELS SKIRTING HEATING BOILER
More informationTempLowHT Steam Desuperheater Model: 59/69/79
NARVIK-YARWAY The TempLowHT utilizes the fundamental design concepts of the standard Templow, designed for temperatures up to 1150 F (621 C). The TempLowHT is designed to eliminate sliding trim parts in
More informationYarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty
Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide of models, sizes and materials to satisfy the specifications of the power, pulp and paper industries along with
More informationDirect steam injection sterilizer
Stematic Long Run Stematic Long Run Direct steam injection sterilizer STEMATIC LONG RUN - Direct steam injection sterilizer Stematic long run Direct steam injection sterilizer Expression of Rossi & Catelli
More informationTOTAL ENGINEERED SOLUTIONS CSG PROCESS FILTER MODEL CL
TOTAL ENGINEERED SOLUTIONS CSG PROCESS FILTER MODEL CL19-1200 INTRODUCTION One of the major problems occurring in the CSG industry is dealing with large volumes of water containing coal fines, debris and
More informationSeries 774 Automatic Skid Package
Fluid Engineering 1432 Walnut St Erie, PA 16502 USA PH 814.453.5014 FAX 814.452.6573 www.fluideng.com sales @fluideng.com CONTINUOUS FLOW The Fluid Engineering 774 Strainer Package is designed to handle
More informationParts List. Modular Crescent Cuber. Models KM-1340MAH, MWH, MRH/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1340MAH, MWH, MRH/3 hoshizakiamerica.com Number: 71251 Issued: 5-1-2006 Revised: 9-7-2016 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main
More informationUNIVERSITY OF BOLTON SCHOOL OF ENGINEERING B.ENG (HONS) ELECTRICAL & ELECTRONIC ENGINEERING EXAMINATION SEMESTER /2017 RENEWABLE ENERGIES
UNIVERSITY OF BOLTON TW20 SCHOOL OF ENGINEERING B.ENG (HONS) ELECTRICAL & ELECTRONIC ENGINEERING EXAMINATION SEMESTER 2-2016/2017 RENEWABLE ENERGIES MODULE NO: EEE6006 Date: Monday 15 May 2017 Time: 2.00
More informationStandard Duty Que - Temp Desuperheater Model: 33 / 43
Model: 33 / 43 Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power-pulp
More informationINDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified
05-0514 INDUSTRIAL GENERATORS steam or overheated water 97/23/CE - P.E.D. certified TECHNIQUE, COMPETENCE, EXPERIENCE OR INDUSTRY The steam and overheated water production cost is a decisive factor for
More informationInquiry-Based Physics in Middle School. David E. Meltzer
Inquiry-Based Physics in Middle School David E. Meltzer Mary Lou Fulton Teachers College Arizona State University Mesa, Arizona U.S.A. Supported in part by a grant from Mary Lou Fulton Teachers College
More informationMODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS
5301399 MODEL NO. UTL-40-5 40 Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS ASSEMBLY The sprayer is fully assembled at the factory. The only assembly necessary is
More informationSolenoid Valve ST-IA-series
2/2-WAY INDIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-IA-series The ST-IA is an indirect operated 2/2-way solenoid valve. The valve is normally closed. The solenoid valves have an orifice of 13 to
More informationME2301 THERMAL ENGINEERING L T P C OBJECTIVE:
ME2301 THERMAL ENGINEERING L T P C 3 1 0 4 OBJECTIVE: To integrate the concepts, laws and methodologies from the first course in thermo dynamics into analysis of cyclic processes To apply the thermodynamic
More information& PumpRight for PWM Control. Maximum Pump Flow and Application Rates. Max Flow GPM
396-001070 PumpRight Fertilizer System for John Deere GS2 2600 & GS3 2630 & PumpRight for PWM Control Maximum Pump Flow and Application Rates Number of Diaphragms Max Flow GPM Max GPA on 40 at 6 MPH Max
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 gal 132 rpm 12 50 rpm 300 540 inches 20 SOLVENT
More informationDESIGN AND TECHNOLOGY
Candidate Name Centre Number 0 Candidate Number GCSE 142/04 DESIGN AND TECHNOLOGY PAPER 2 FOCUS AREA: SYSTEMS AND CONTROL TECHNOLOGY Higher Tier A.M. MONDAY, 2 June 2008 1 1 2 hours Leave Blank Question
More informationSolenoid Valve ST-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-SA-series The ST-SA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. The body material can be brass or stainless
More informationS200-P Passport Series Fire Pump Service Parts List
Document Number Issue Date 04/08/13 Rev. Date 9/24/18 S200-P Passport Series Fire Pump Service Parts List Index: Component See Pages Body and Impeller 2, 3 Pedestal and Primers 4, 5 Cross Section Views
More informationDon t Freeze the Engine Answer Key
Don t Freeze the Engine Answer Key Antifreeze is used in a car s cooling system to protect the engine from freezing at various temperatures. In this activity, you will use an antifreeze chart to determine
More informationSERIES COOLING TOWER SINGLE-CELL UP TO 1700HRT COOLING CAPACITY
EC-S SERIES COOLING TOWER SINGLE-CELL UP TO 1700HRT COOLING CAPACITY High Performance Counterflow Type CERTIFICATE NUMBER: 12-41-01 ENERGY CONSERVATION SPACE SAVING DESIGN FLEXIBILITY CERTIFICATE NUMBER:
More informationGLASSMAN EUROP CERCAT : A Technology for Air Pollution Control. Process, Construction & Performances
GLASSMAN EUROP CERCAT : A Technology for Air Pollution Control Process, Construction & Performances SUGAR INDUSTRY ALCOHOL DRYING ENVIRONMENT 13 th 14 th May 2009 1 PROGRAMME 1. MAGUIN S.A.S. presentation
More informationMulti Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Multi Ejector Solution TM, consists of a CTM 1 and CTM 2 liquid valves and an AK-PC 782A controller.
More informationMr. Freeze QUALITATIVE QUESTIONS
QUALITATIVE QUESTIONS Many of the questions that follow refer to the graphs of data collected when riding Mr. Freeze with high tech data collection vests. With your I.D., you can borrow a vest without
More informationQuali cations. Forename(s) Surname Number of seat
FOR OFFICIAL USE Quali cations N5National 205 X723/75/0 Mark Engineering Science TUESDAY, 2 MAY :00 PM 2:30 PM *X723750* Fill in these boxes and read what is printed below. Full name of centre Town Forename(s)
More informationStartup and Operation of SEE-THRU Nuclear Power Plant for Student Performance MP-SEE-THRU-01 Rev. 018
Student Operating Procedure Millstone Station Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance Approval Date: 01/12/2011 Effective Date: 01/12/2011 TABLE OF CONTENTS 1. PURPOSE...3
More informationStandard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34
Narvik-Yarway covers requirements for desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp & paper industry
More informationRev.2.06A www.cmadishmachines.com Table of Contents EST-44 1. PARTS MANUAL... 3 1.1. Initial Parts Kit... 3 1.2. Exploded View Drawings... 4 1.2.1. Cabinet Assembly... 4 1.2.2. Control Box Assembly (3
More informationSEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL
SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Model Number: Service: Code: Installation Date: Installation
More informationWork done and Moment. When using the equipment, John wants to do 300J of work in each lift.
Yr 11 Physics worksheet Paper 2 Work done and Moment Q1) The diagram shows weightlifting equipment found in most gyms. When using the equipment, John wants to do 300J of work in each lift. He can vary
More informationTECHNICAL INFORMATION HXL8018S-K 11/2012 / 733-B 1
HXL8018S-K 1 WORKING MACHINE WITH SOLVENT HYDROCARBON / GREEN EARTH / SOLVON K4 MACHINE CAPACITY 18 Kg 40 Lbs BASKET Diameter 900 mm 35.4 inches Depth 535 mm 21 inches Volume 340 Lt 12 cu.ft Wash speed
More informationFile No: 7(600)/2016/Pur Date:
File No: 7(600)/206/Pur Date: 09.06.207 Revised Technical Specification issued after the Pre-Bid Conference for Bio-Diesel Plant using Leather Fleshing Waste, Chamois Leather, Fish Oil and Slaughter House
More informationSolenoid Valve DF-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve DF-SA-series The DF-DA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. These valves have an orifice of 16 to
More informationTUTORIAL QUESTIONS FOR COURSE TEP 4195
TUTORIL QUESTIONS FOR COURSE TEP 4195 Data: Hydraulic Oil Density 870 kg/m 3 bsolute viscosity 0.03 Ns/m 2 Spool valve discharge coefficient 0.62. 1) hydrostatic transmission has a variable displacement
More informationIndex. LIST No. GENERAL INFORMATION 1/01, 1/02. General Information 1/03. Selection of Valve Types VALVE TYPE FL 441 (STANDARD PRESSURE SERIES) 2/01
Index SECTION LIST No. DESCRIPTION PAGE No. GENERAL INFORMATION General Information Selection of Valve Types /0, /0 /0 VALVE TYPE FL (STANDARD PREURE SERIES) Method of Model Numbering /0 General Arrangement
More informationEnergy Conversions Questions CfE
Energy Conversions Questions CfE 1) A 0.02kg mass is held at a height of 0.8m above the ground. a) Calculate the gravitational potential energy stored in the mass before it is dropped. b) i) State the
More informationDirect Contact Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A
MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More information