Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance MP-SEE-THRU-01 Rev. 018

Size: px
Start display at page:

Download "Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance MP-SEE-THRU-01 Rev. 018"

Transcription

1 Student Operating Procedure Millstone Station Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance Approval Date: 01/12/2011 Effective Date: 01/12/2011

2 TABLE OF CONTENTS 1. PURPOSE Objective Discussion Applicability PREREQUISITES General PRECAUTIONS Safety Precautions General Precautions Operating Limits INSTRUCTIONS Establish Initial Plant Conditions Plant Heatup Establishing Pressurizer Steam Bubble Heatup and Secondary Plant Startup of 18

3 1. PURPOSE 1.1 Objective This procedure provides instructions for the heat-up and power operation of the SEE- THRU Nuclear Power Plant. Students under the instruction of a qualified instructor may use this procedure. 1.2 Discussion This procedure provides instructions for drawing a pressurizer bubble, heating-up the reactor plant, and operating the turbine-generator and secondary plant of the SEE-THRU Nuclear Power Plant. The PYREX glass that is used for the pressure vessels of the SEE-THRU Nuclear Power Plant needs to be gradually heated up to prevent stress damage to the glass. Therefore, several hold points will be observed during the plant heat up to allow for thermal equalization of the glass. The reactor coolant system (pressurizer, reactor vessel, steam generators (primary side), and piping) will be water solid at the beginning of this exercise. When the reactor coolant system is in this condition, changes in temperature will result in pressure changes due to thermal expansion or contraction of primary system water. The water in the pressurizer is heated to a saturated condition with an electric heater. When the water in the pressurizer reaches saturation temperature, a steam bubble in the pressurizer is established by lowering pressurizer water level to approximately 50%. The reactor coolant is concurrently heated by electric heater rods (which simulate the reactor core) and is circulated, through two steam generators, via two reactor coolant pumps. As the reactor plant heat up continues, the water in the steam generators will begin to boil and the steam will be transported to the secondary plant. The heat input (reactor power) into the reactor coolant system is raised and the turbine-generator is started using the steam from the steam generators. 1.3 Applicability This procedure is applicable for student operation of the SEE-THRU Nuclear Power Plant. 3 of 18

4 2. PREREQUISITES 2.1 General The instructor has completed procedure Millstone Power Station SEE-THRU Nuclear Power Plant Preparation for Operation Students have reviewed the SEE-THRU Nuclear Power Plant layout and are familiar with the locations of the major plant components, operating controls, local valves, pumps and instrumentation indicators Students have reviewed and understand the safety precautions, general precautions and SEE-THRU Nuclear Power Plant operating limits The instructor has conducted a pre-job brief with all students for this activity. 4 of 18

5 3. PRECAUTIONS 3.1 Safety Precaution Always operate the SEE-THRU Nuclear Power Plant with the containment plexiglass (cylinder and dome) and component plexiglass covers in place to prevent scalding from hot water or steam in the event of a primary or secondary plant leak or rupture. The containment and component covers must also be in place to prevent serious lacerations or other injuries from broken/flying glass should a glass component break. 3.2 General Precautions When starting any pump, STOP it immediately if there is an abnormal noise or if an abnormal noise develops during operation Do NOT run any pump at a shutoff head for an extended period of time ENSURE that the pressurizer heaters and reactor vessel heaters are completely covered with water anytime the heaters are energized Do NOT allow the condenser to pump empty because this will cause air binding of the Condensate Pump and/or Feed Pump When the reactor coolant system is solid (no steam bubble in pressurizer), a small change in temperature can result in a significant change in system pressure Start up of SEE-THRU Nuclear Power Plant is NOT allowed if reactor coolant system Auto/Manual Relief Valve is NOT operational When shutting Feedwater Regulating Valves FW1 and FW2, Reactor Vessel Vent Valve RC-15, and Pressurizer PORV Isolation Valve RC-22, do NOT run them hard into their shut seat. This will prevent damaging the valves Do NOT allow Feedwater Outlet temperature to exceed 170 o F. 3.3 Operating Limits Ensure that the following operating limits are not exceeded: a. Reactor coolant system pressure is maintained less than 23 psi b. Reactor temperature is maintained less than 275 F c. Pressurizer temperature is maintained less than 275 F d. Condenser water level is maintained greater than 1/3 full e. Containment temperature is maintained less than 180 F 5 of 18

6 4. INSTRUCTIONS 4.1 Establish Initial Plant Conditions Circ Water Regulating Valve CW1 regulates domestic water supply pressure to the Containment Air Recirculation Cooling (CARC) unit and the Quench Tank. The domestic water supply pressure is not stable and periodic adjustment of the circulating water pressure may be required during operation of the SEE-THRU Nuclear Power Plant Initiate circulating water and containment cooling by performing the following: a. THROTTLE OPEN Circ Water Reg CW1 to obtain an initial reading of psi as read on CW system pressure gauge. 1) PERIODICALLY CHECK the CW system pressure gauge to ensure pressure is between 15 to 20 psi. b. VERIFY no leaks exist at the circulating water connections to and from the model. 1) IF leaks are present, NOTIFY instructor for further guidance. c. VERIFY circulating water sump pump starts as tank fills. d. START the Containment Air Recirculation Cooling (CARC) fan VERIFY the initial operating conditions of the following components: Pressurizer is water solid Reactor vessel is water solid Passive Accumulator tank level is approximately 1/3 full Passive Accumulator tank pressure is approximately 0 psi Condenser is 1/3 to 1/2 full Quench Tank / RWST is 1/2 to 2/3 full Steam Generator A Level approximately ½ to 1 inch above tube bundle Steam Generator B Level approximately ½ to 1 inch above tube bundle IF any of the initial operating conditions in step do not exist, ADJUST water level or pressure as directed by the instructor. 6 of 18

7 CAUTION When pressurizing the passive accumulator, do not exceed 9 psi on Passive Accumulator Pressure gauge. Over pressurization of the passive accumulator could result in damage to the passive accumulator Perform the following to pressurize the passive accumulator: a. START Safety Inj Pump - P1. b. OPEN Fill - SI5 valve. c. WHEN Passive Accumulator Pressure gauge indicates 6-8 psi, CLOSE Fill - SI5 valve. d. STOP Safety Inj Pump - P1. - End of Section of 18

8 CAUTION Monitor pressurizer pressure (Red LED) and reactor temperature (F2) during plant heatup. 1. The Master Display/Controller Function Keys are as follows: F1 Main Menu/Reactor Coolant Loop hot and cold leg temperatures F2 Pressurizer water, reactor and PORV tailpipe temperatures F3 Main steam and feedwater inlet and outlet temperatures F4 Quench Tank, Circulating Water inlet and outlet, and Containment temperatures F5 Pressurizer Control F6 Pressurizer Manual Control % Output Control F7 Pressurizer Manual to Automatic and Automatic to Manual control mode change F8 Pressurizer Automatic Pressure Control Setpoint 2. When using the Master Display/Controller, F1 must be used to return the display to the Main Menu in order to use the F2, F3, F4, F5 and F Plant Heatup START Reactor Coolant Pump P START Reactor Coolant Pump P Perform the following to start pressurizer heatup: a. PRESS F1 then F5 on the Master Display/Controller b. VERIFY 0% output is displayed. c. VERIFY Pressurizer Control is in MANUAL d. PLACE the Pressurizer Heater switch in the ON position. e. PRESS F6 On the Master Display/Controller f. ENTER 50% (TYPE in 50 and depress the enter key) g. VERIFY 50% output is displayed 8 of 18

9 h. PRESS F1 then F2 on the Master Display/Controller. To observe pressurizer heater performance, look directly at the pressurizer to observe the shimmering waves of convection currents as the pressurizer heater begins to heat the water. CAUTION When the reactor coolant system is solid (no steam bubble in pressurizer), a small change in temperature could result in a significant change in system pressure Perform the following steps to manually control reactor coolant system pressure during heatup: Dual Verification a. CLOSE valve RC-15 (manual valve downstream of valve RC-1) Performer Verifier (Dual) b. OPEN valve RC-1 (reactor vent). 1) VERIFY Pressurizer Pressure is not decreasing. 2) IF Pressurizer Pressure lowers after opening valve RC-1, PERFORM the following: a) CLOSE valve RC-1 b) OPEN valve RC-15 Independent Verification Performer Verifier (Independent) c) ESTABLISH alternate drain path as directed by instructor 1. The Low System Pressure alarm will clear when pressurizer pressure raises above 10 psi. 2. Step (reactor startup) can be started while plant pressure is being raised to the pressure band in step c. c. WHEN Pressurizer Pressure is >10 psi, THROTTLE valve RC-15 as necessary to maintain pressure between 10 and 13 psi. 9 of 18

10 4.2.5 Initiate reactor startup and heat up of the reactor coolant system as follows: a. PRESS the Reactor Trip push button to reset the reactor trip. b. VERIFY Reactor Trip button red light is not lit and Reactor Trip alarm has cleared. c. RAISE Reactor Power to 10 amperes. d. WHEN Pressurizer Water Temperature is >125 o F, RAISE Reactor Power to 18 amperes. The PYREX glass that is used for the pressure vessels of the SEE- THRU Nuclear Power Plant needs to gradually heat up to prevent stress damage to the glass. There are several hold points during the plant heatup to allow for thermal equalization of the glass WHEN Reactor Temperature indication reaches 120 F: a. LOWER Reactor Power to between 6 and 10 amperes. b. MAINTAIN Reactor Temperature at approximately 120 F for >5 minutes WHEN the 5-minute temperature hold is complete, RAISE Reactor Power to 18 amperes WHEN Reactor Temperature indication reaches 135 F: a. LOWER Reactor Power to between 6 and 10 amperes. b. MAINTAIN Reactor Temperature at approximately 135 F for >5 minutes WHEN the 5-minute temperature hold is complete, RAISE Reactor Power to 18 amperes WHEN Reactor Temperature indication reaches 150 F: a. LOWER Reactor Power to between 6 and 10 amperes. b. MAINTAIN Reactor Temperature at approximately 150 F for >5 minutes WHEN the 5-minute temperature hold is complete, RAISE Reactor Power to 18 amperes. 10 of 18

11 Step (increasing pressurizer heatup rate) can be performed while plant pressure is being raised to the pressure band in step RAISE Pressurizer Pressure to between 17 and 18.5 psi as follows: a. CLOSE valve RC-15. b. WHEN Pressurizer Pressure is between 17 and 18.5 psi, THROTTLE RC-15 as necessary to maintain pressure between 17 and 18.5 psi RAISE pressurizer heat up rate as follows: a. PRESS F1 then F5 On the Master Display/Controller b. VERIFY 50% output is displayed. c. PRESS F6 On the Master Display/Controller d. ENTER 70% (TYPE in 70 and depress the enter key). e. VERIFY 70% output is displayed. f. PRESS F1 then F2 on the Master Display/Controller WHEN Reactor Temperature indication reaches 180 F, LOWER Reactor Power to between 6 and 10 amperes. - End of Section of 18

12 4.3 Establishing Pressurizer Steam Bubble CAUTION Do NOT allow pressurizer level to lower to below 40% or pressurizer pressure to exceed 23 psi WHEN Pressurizer Water temperature is >250 F: a. VERIFY Pressurizer Level is >50%. b. SLOWLY OPEN valve RC-15 to create a steam bubble in the pressurizer. 1) WHILE lowering pressurizer level, MAINTAIN pressurizer pressure above 16 psi. c. CLOSE valve RC-15 when pressurizer level has lowered to approximately 50%. d. CYCLE valve Pressurizer Spray -RC4 as necessary to maintain pressurizer pressure between 19 and 21 psi. Pressurizer pressure may be momentarily erratic when the Pressure Control is initially placed in Automatic mode ESTABLISH automatic pressurizer pressure control as follows: a. PRESS F1 then F5 on the Master Display/Controller b. PRESS F7 to switch from Manual to Automatic pressure control mode. c. IF open, SHUT valve Pressurizer Spray-RC4. d. VERIFY Pressurizer Pressure is stable between 19 and 21 psi WHEN Pressurizer Pressure is stable between 19 and 21 psi: a. PLACE the Injection SI1 key switch to Normal (key in vertical position - ¼ turn COUNTER CLOCKWISE). b. OPEN valve Flood SI2 to create a flow path from the passive accumulator. c. VERIFY passive accumulator level and pressure are stable. 12 of 18

13 Independent Verification CLOSE Reactor Vent valve RC FULLY OPEN valve RC-15. Performer Verifier (Independent) a. VERIFY pressurizer level is stable at approximately 50%. - End of Section of 18

14 4.4 Heatup and Secondary Plant Startup Do not allow loop T H (F1) to exceed 242 o F Perform the following steps to heatup the reactor coolant system: a. MONITOR reactor coolant loop (F1) and main steam (F3) temperatures during the plant heat up. b. RAISE Reactor Power to 18 amperes WHEN Loop Temperature indication reaches 210 F: a. LOWER Reactor Power to between 9 and 11 amperes. b. MAINTAIN Loop Temperature at approximately 210 F for >2 minutes. c. OPEN valve Pressurizer Spray RC4 to initiate pressurizer spray. d. VERIFY Pressurizer Pressure is stable between 19 and 21 psi. Because of its design, starting and stopping the turning gear several times may be necessary in order to obtain proper rotational direction (counter-clockwise as viewed from the turbine end) START the Turbine Generator Turning Gear IF Steam Generator water levels are greater than 1 inch above the U-tubes, RAISE Reactor Power to 28 amperes. CAUTION When shutting Feedwater Regulating Valves FW1 and FW2, do not run them hard into their shut seats. This will damage the valves VERIFY the following parameters: a. Valves MSIV-MS1 and MSIV-MS2 are OPEN b. Valve Bypass-MS3 (Steam Dump to the Condenser) is OPEN. c. Feedwater Regulating Valve FW1 is CLOSED d. Feedwater Regulating Valve FW2 is CLOSED. 14 of 18

15 e. Demineralizer Inlet valve MS-19 is OPEN f. Demineralizer Outlet valve MS-20 is THROTTLED 1/2 OPEN. g. Condenser water level is 1/3 to 1/2 full STARTUP the secondary plant as follows: a. START Condensate Pump P4. 1) VERIFY Feedwater System Pressure raises to between 3 and 10 psi. 2) IF Feedwater System Pressure did NOT raise when condensate pump was started, NOTIFY instructor that system may be air bound. b. START Feed Pump P3. 1) VERIFY Feedwater System Pressure raises to between 10 and 15 psi. 2) IF Feedwater System Pressure did NOT raise when feed pump was started, NOTIFY instructor that system may be air bound ESTABLISH feedwater flow to the steam generators as follows: a. OPEN Feedwater Regulating Valves FW1 and FW2 to float the rotometer balls to an initial setting of approximately 5 on the vertical feedwater flow gauges. b. THROTTLE, as necessary, FW1 and FW2 to maintain a water level of approximately ½ to 2 above the S/G U-tubes IF not performed previously, RAISE Reactor Power to 28 amperes. CAUTION The Turbine Generator Turning Gear must be stopped expeditiously after closing Bypass-MS3 to avoid damage to the Turbine Generator Turning Gear WHEN Main Steam Pressure is >1.5 psi on gauge PI-5, perform the following to startup the steam turbine: a. OPEN valve TSV-MS4 (Steam to the Main Turbine). b. VERIFY Turbine Trip annunciator light is NOT lit. c. CLOSE valve Bypass-MS3 (Steam Dump to the Condenser). 15 of 18

16 d. IMMEDIATELY STOP the Turbine Generator Turning Gear. e. VERIFY that the Main Turbine is rotating by observing the Turbine Speed LED. 1) MONITOR Turbine Speed to ensure it remains < 3400 RPM. 2) IF turbine speed exceeds 3380 RPM, CYCLE valve Bypass-MS3 (Steam Dump to the Condenser) as necessary to maintain turbine speed <3400 RPM. f. TURN the black Turbine Generator Exciter potentiometer to the fully counter-clockwise (minimum) position. g. WHEN Turbine Speed exceeds 1800 rpm, TURN ON the Turbine Generator Exciter switch. h. While MONITORING the Generator Output Power meter, RAISE the turbine generator output by turning the Turbine Generator Exciter potentiometer clockwise to its maximum position, not to exceed 750 watts, as read on the Generator Output Power meter LOWER Reactor Power to 26 amperes MAINTAIN the following parameters: Reactor Power = 23 to 26 amperes Primary Temp = Loop T H <242 o F Primary Pressure = 19 to 21 psi Pressurizer Level = approximately 50% Condenser Level = 1/3 to 1/2 full S/G Levels = visible level above the U-tubes Turbine Speed = < 3400 rpm Containment Temp = <180 o F 16 of 18

17 CAUTION Do NOT allow the feedwater outlet temperature to exceed 170 F when performing step The feedwater heater condensate level should be maintained slightly above the drain orifice to prevent the steam from bypassing directly to the condenser IF desired, perform the following steps to place the feedwater heater in operation: a. VERIFY Main Steam Pressure PI5 is greater than 2 psi. b. VERIFY CLOSED manual isolation valves MS-9 and MS-16. c. OPEN valve Feedwater Supply MS5. d. OPEN valve Feedwater Heater Drain MS6. e. Slowly OPEN manual valve MS-16 to pressurize the feedwater heater. f. THROTTLE OPEN feedwater heater drain manual isolation valve MS-9 as necessary to maintain desired condensate level (about 1/3 full). g. PRESS F1 then F3 On the Master Display/Controller to display Feedwater Temperature. h. THROTTLE manual isolation valve MS-16 as necessary to maintain Feedwater Outlet temperature < 170 F. The vacuum pump should NOT be operated continuously for more than 5 minutes. The pump should only run for short periods to demonstrate the improved efficiency of the steam cycle with a lower condenser vacuum IF desired, perform the following steps to place the vacuum pump in operation: a. OPEN manual isolation valve MS-12. b. CLOSE manual isolation valve MS-13. c. START Vacuum Pump P5. d. VERIFY proper operation by noting a lower in condenser pressure as read on the Condenser Vacuum Gauge PI of 18

18 e. After 5 minutes or less, STOP Vacuum Pump-P5. f. OPEN manual isolation valve MS-13. g. CLOSE manual isolation valve MS End of Section of 18

AP1000 European 7. Instrumentation and Controls Design Control Document

AP1000 European 7. Instrumentation and Controls Design Control Document 7.3 Engineered Safety Features AP1000 provides instrumentation and controls to sense accident situations and initiate engineered safety features (ESF). The occurrence of a limiting fault, such as a loss

More information

AP Plant Operational Transient Analysis

AP Plant Operational Transient Analysis www.ijnese.org International Journal of Nuclear Energy Science and Engineering Volume 3 Issue 2, June 2013 AP1000 1 Plant Operational Transient Analysis LIU Lixin 1, ZHENG Limin 2 Shanghai Nuclear Engineering

More information

AP1000 European 5. Reactor Coolant System and Connected Systems Design Control Document

AP1000 European 5. Reactor Coolant System and Connected Systems Design Control Document CHAPTER 5 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5.1 Summary Description This section describes the reactor coolant system (RCS) and includes a schematic flow diagram of the reactor coolant system

More information

Secondary Coolant 301

Secondary Coolant 301 Secondary Coolant 301 Instructor Rusty Walker Hill PHOENIX Learning Center Secondary Coolant 301 Start-Up Procedures Secondary Coolant 301 Objectives Describe the initial startup procedures for a medium

More information

POWER GENERATION SYSTEMS

POWER GENERATION SYSTEMS POWER GENERATION SYSTEMS The Power Generation Systems on HI 595 CF&D consist of three Waukesha 7042 gas driven generators and two diesel driven generators. Two of the three Gas Generators must run to provide

More information

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Standard Check Valve The standard check valve permits free flow in one direction

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

ANALYSIS OF BREST-OD-300 SAFETY DURING ANTICIPATED OPERATIONAL OCCURRENCES

ANALYSIS OF BREST-OD-300 SAFETY DURING ANTICIPATED OPERATIONAL OCCURRENCES ANALYSIS OF BREST-OD-300 SAFETY DURING ANTICIPATED OPERATIONAL OCCURRENCES D.V. Didorin, V.A. Kogut, A.G. Muratov, V.V. Tyukov, A.V. Moiseev (NIKIET, Moscow, Russia) 1. Brief description of the aim and

More information

Hope Creek Variable Frequency Drive

Hope Creek Variable Frequency Drive Hope Creek Variable Frequency Drive 2018 Power Plant Simulation Conference Houston, TX January 14-18, 2018 Hope Creek Variable Frequency Drive Simulation John Stone Senior Engineer - CORYS Presentation

More information

First Correlating Revision No. 1-NFPA [ Section No ]

First Correlating Revision No. 1-NFPA [ Section No ] First Correlating Revision No. 1-NFPA 85-2013 [ Section No. 3.3.52.1 ] 3.3.52.1 Booster Fan. A device fan used to assist in the supply of air to, or the removal of flue gas products from, the combustion

More information

LESSONS LEARNED FORSMARK EVENT Presented To IEEEE

LESSONS LEARNED FORSMARK EVENT Presented To IEEEE LESSONS LEARNED FORSMARK EVENT Presented To IEEEE Thomas Koshy Member of the Task Group on Forsmark Chief of Mechanical & Electrical Engineering Office of Research, USNRC Thomas.Koshy@nrc.gov 1 Agenda

More information

Operating instructions Form no safety definitions

Operating instructions Form no safety definitions Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety

More information

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL IMPORTANT These instructions are intended as a guide for the Installing Contractor and as a reference for the Operator, Owner and Serviceman. RETAIN

More information

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-10A & FTI-20A Single Tank Installation Manual

More information

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION SECTION 3.00 ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION Be sure that the clutch, circuit breaker, or other main power transmission device is disconnected. Generators develop voltage as soon as the

More information

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc

Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc Fuel flexibility and reliability in Combined Cycle gas turbine applications Schuyler McElrath Gas Turbine Consultant JASC: Jansen s Aircraft Systems Controls, Inc schuyler@jasc-controls.com www.jasc-controls.com

More information

Current Status of the Melcor Nodalization for Atucha I Nuclear Power Plant. Zárate. S.M. and Valle Cepero, R.

Current Status of the Melcor Nodalization for Atucha I Nuclear Power Plant. Zárate. S.M. and Valle Cepero, R. Current Status of the Melcor Nodalization for Atucha I Nuclear Power Plant Zárate. S.M. and Valle Cepero, R. presentado en USNRC Cooperative Severe Accident Research Program (CSARP), Maryland, EE. UU.,

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31 LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the

More information

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve

More information

AP1000 European 7. Instrumentation and Controls Design Control Document

AP1000 European 7. Instrumentation and Controls Design Control Document 7.7 Control and Instrumentation Systems The function of the AP1000 control systems is to establish and maintain the plant operating conditions within prescribed limits. The control system improves plant

More information

The Establishment and Application of TRACE/FRAPTRAN Model for Kuosheng Nuclear Power Plant

The Establishment and Application of TRACE/FRAPTRAN Model for Kuosheng Nuclear Power Plant The Establishment and Application of /FRAPTRAN Model for Kuosheng Nuclear Power Plant S. W. Chen, W. K. Lin, J. R. Wang, C. Shih, H. T. Lin, H. C. Chang, W. Y. Li Abstract Kuosheng nuclear power plant

More information

PALO VERDE NUCLEAR GENERATING STATION

PALO VERDE NUCLEAR GENERATING STATION PALO VERDE NUCLEAR GENERATING STATION Mechanical Maintenance Training Classroom Lesson Mechanical Maintenance Training Date: 7/23/2010 5:42:15 AM LP Number: NMC61C000202 Rev Author: LEE BAKER Title: Lubrication

More information

Generator, Unit Hydrogen, Seal Oil, Stator Coolant, Demin Water Plant Operations Training Huntly Power Station: Units 1-4 Assessment ID: 8014, 8012, 8009, 8015, 8016 NZQA Unit Standard: 17413 Assessment

More information

Single-Valve Powerstation

Single-Valve Powerstation Single-Valve Powerstation Description Powerstation is a complete, fully assembled water tempering system, designed to provide safe water throughout commercial and institutional facilities. Powerstation

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Automated Fuel Maintenance System FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 01/01/2014 Rev A - Fuel Technologies - FTI-2.8 with ModBus OPERATIONS & MAINTENANCE CONTENTS

More information

SUB-CHAPTER B.3 COMPARISON TABLE COMPARISON WITH REACTORS OF SIMILAR DESIGN (N4 AND KONVOI)

SUB-CHAPTER B.3 COMPARISON TABLE COMPARISON WITH REACTORS OF SIMILAR DESIGN (N4 AND KONVOI) CHAPTER B: INTRODUCTION AND GENERAL DESCRIPTION OF THE SUB-CHAPTER: B.3 SECTION : - PAGE : 1 / 9 SUB-CHAPTER B.3 COMPARISON TABLE COMPARISON WITH REACTORS OF SIMILAR DESIGN (N4 AND KONVOI) A comparison

More information

Page 2. Pitot tube anti-ice. Windshield Anti-ice Components. Propeller Anti-ice Components. Wing boot anti-ice pneumatic components

Page 2. Pitot tube anti-ice. Windshield Anti-ice Components. Propeller Anti-ice Components. Wing boot anti-ice pneumatic components Ice & Rain Trainer Component Location Page 2 Pitot tube anti-ice Propeller Anti-ice Components Windshield Anti-ice Components Wing boot anti-ice pneumatic components Control and Indicating Components 110

More information

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc. ARCHON Industries, Inc. Washdown Stations Models WD2010L, WD2010, WD2010H Installation / Operation / Maintenance Instructions 1 This manual has been prepared as an aid and guide for personnel involved

More information

BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL

BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL Website: www.recoveredenergy.com Email: oilwatersales@recoveredenergy.com BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL BOSS 2.2T/107 BOSS 5T/107 BOSS 11T/107 BOSS 25T/107 BOSS 45T/107 Installation

More information

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks. ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks. 1. Check log book for incomplete compliance for further operation. 2.

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

HP COOL TECH, INC. COOLANT PUMP. PowerPump. INSTALLATION MANUAL HANWHA XD20 Series 10000/11000

HP COOL TECH, INC. COOLANT PUMP. PowerPump. INSTALLATION MANUAL HANWHA XD20 Series 10000/11000 HP COOL TECH, INC. COOLANT PUMP PowerPump INSTALLATION MANUAL HANWHA XD20 Series 10000/11000 1 TABLE OF CONTENTS Page Topic 3 Introduction 3 Specifications 3 Warning 4 Safety 5, 6, 7 Installation 8 Use

More information

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

(770) Turning Parts Changers Into TROUBLESHOOTERS!

(770) Turning Parts Changers Into TROUBLESHOOTERS! Hydraulic Consulting, Inc. Turning Parts Changers Into TROUBLESHOOTERS! This e-book manual is your customized troubleshooting manual in Adobe Acrobat Portable Document File (PDF) format. It requires the

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

Fisher 644 and 645 Differential Pressure Pump Governors

Fisher 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Fisher 644 and 645 Differential Pressure Pump Governors Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services...

More information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,

More information

Evaluating Generation Considering All Plant Losses and Efficiencies Duane H. Morris, P.E. Tennessee Valley Authority

Evaluating Generation Considering All Plant Losses and Efficiencies Duane H. Morris, P.E. Tennessee Valley Authority Evaluating Generation Considering All Plant Losses and Efficiencies Duane H. Morris, P.E. Tennessee Valley Authority James W. Brower Scientech a business unit of Curtiss-Wright Flow Control Company Evaluating

More information

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI

More information

SECTION 2.05 FUEL SYSTEM DESCRIPTION FUEL SYSTEM COMPONENTS

SECTION 2.05 FUEL SYSTEM DESCRIPTION FUEL SYSTEM COMPONENTS SECTION 2.05 FUEL SYSTEM DESCRIPTION FUEL SYSTEM COMPONENTS The engine fuel system consists of the following engine mounted components: Carburetors Throttle valves Fuel pressure regulator and balance line(s)

More information

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE I.O.M. #082 1/08 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covers Models with LE Series Instrument. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 Service Department

More information

I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models with HE Series Instrument.

I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models with HE Series Instrument. I.O.M. #081 updated : 09/19/2014 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE Covers Models with HE Series Instrument. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277

More information

Air / Hydraulic Pump

Air / Hydraulic Pump Form No. 538016 Parts List & Operating Instructions for: 2510A Original Instructions Air / Hydraulic Pump Maximum Capacity: 690 bar (10,000 psi) Description: The 2510A air/hydraulic pump is designed to

More information

348002K/348012K Manifold Block Style Service Manual 12/2000

348002K/348012K Manifold Block Style Service Manual 12/2000 348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation

More information

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE 100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up

More information

Pressure degassing systems

Pressure degassing systems Pressure degassing systems A degassing system consists of several components: Degassing unit Feedwater tank Instrumentation and control technology Steel structures, platforms and ladders Exhaust vapours

More information

HS Refrigeration Screw Compressor Troubleshooting Guidelines. SG March 2014

HS Refrigeration Screw Compressor Troubleshooting Guidelines. SG March 2014 HS Refrigeration Screw Compressor Troubleshooting Guidelines SG-0003-01 March 2014 Refrigeration Screw Compressor Troubleshooting Guidelines SG-0003-01 March 2014 BITZER Screw Compressors CS High Temp

More information

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit Exercise 3-1 Basic Hydraulic Circuit EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the hydraulic schematic and components of the nacelle trainer. You will identify

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100 Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP-53-030/055/100 Rev. 1 3/21/11 K.G. Type - John Wood #JWOP-53-030/055/100, Outdoor Glycol Feed System Capacity 30/55/100 Gallons

More information

¼ to 1HP Chiller Service Manual

¼ to 1HP Chiller Service Manual ¼ to 1HP Chiller Service Manual Before performing any service to the unit, reset the controller to its default settings. It is our experience that many problems can be resolved by doing so. See Sec. 3.1

More information

Multi-Tank Submersible Pump Install Manual

Multi-Tank Submersible Pump Install Manual Multi-Tank Submersible Pump Install Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011

More information

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet

More information

Roth NP Manifold System Installation Instructions

Roth NP Manifold System Installation Instructions Roth Industries, Inc. 268 Bellew Avenue South Watertown, NY 360 Ph. 35-755-0 Fax 35-475-0200 www.roth-usa.com info@roth-usa.com ) Product description Constructed of heavy wall extruded nickel plated brass

More information

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA Series Rainwater/Graywater Filtration Systems MODELS: DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA-2F-180 DFA-3F-180 DFA-3F-350 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety

More information

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit Exercise 3-1 Basic Hydraulic Circuit EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the hydraulic schematic and components of the nacelle trainer. You will identify

More information

Engine coolant. Introduction WARNING

Engine coolant. Introduction WARNING Engine coolant Introduction In this section you ll find information about: Warning light and engine coolant temperature gauge Engine coolant specifications Checking engine coolant level and topping off

More information

IMPLEMENTATION OF THE RCP SHIELD MECHANICAL SEAL MODEL IN THE COMANCHE PEAK PRA

IMPLEMENTATION OF THE RCP SHIELD MECHANICAL SEAL MODEL IN THE COMANCHE PEAK PRA IMPLEMENTATION OF THE RCP SHIELD MECHANICAL SEAL MODEL IN THE COMANCHE PEAK PRA Nathan Larson Principal Engineer Daniel Tirsun Fellow Engineer Aaron Moreno Senior Engineer Glen Rose, TX SHIELD is a trademark

More information

Sohn Suk-Whun

Sohn Suk-Whun Application of the Performance Validation Tool for the Evaluation of NSSS Control System Performance Sohn Suk-Whun 29. 1. 29 1 Pre-Op Dynamic Test 2 Test Results 3 Pre-PAT Dynamic Test 4 Conclusion 2 29

More information

PLANT HATCH FEEDWATER SYSTEM OPERATING EXPERIENCE. Significant events from 2015

PLANT HATCH FEEDWATER SYSTEM OPERATING EXPERIENCE. Significant events from 2015 PLANT HATCH FEEDWATER SYSTEM OPERATING EXPERIENCE Significant events from 2015 ICES Report #315779 Hatch Unit 2 March 10, 2015 Startup from 2R23 refueling outage Feedwater Control System (RWL Control)

More information

PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy

PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy April 15, 2013 PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy www.codesignengg.com This article has some reproductions from the PV Newsletter - Volume 1, Issue 10 contributed

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide P/N 0153180 July 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains procedures for locating

More information

Installation & Technical Guide. Domestic & Commercial.

Installation & Technical Guide. Domestic & Commercial. Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower

More information

SECTION 4.05 FUEL SYSTEM MAINTENANCE F18/H24 AND L36/P48 ENGINES

SECTION 4.05 FUEL SYSTEM MAINTENANCE F18/H24 AND L36/P48 ENGINES SECTION 4.05 SYSTEM MAINTENANCE F18/H24 AND L36/P48 ENGINES PHYSICAL REQUIREMENTS supply, pressure, and regulator type will vary with each application. Refer to S6656-23 for applicable regulator information.

More information

Fuel System Diagnosis

Fuel System Diagnosis Page 1 of 6 2001 Chevrolet Express Express, Savana (VIN G) Service Manual Engine Engine Controls - 5.0L and 5.7L Diagnostic Information and Procedures Document ID: 720867 Fuel System Diagnosis Circuit

More information

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL Installation Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Local Union No International Brotherhood of Electrical Workers, AFL-CIO P. O. Box 4790 Walnut Creek, California 94596

Local Union No International Brotherhood of Electrical Workers, AFL-CIO P. O. Box 4790 Walnut Creek, California 94596 Local Union No. 1245 International Brotherhood of Electrical Workers, AFL-CIO P. O. Box 4790 Walnut Creek, California 94596 Company proposes adoption of the attached three versions of the revised Assistant

More information

Delayed Coking. Process Overview

Delayed Coking. Process Overview Process Overview Page 1 of 6 History of the Delayed Coking Process Petroleum coke was first made by the pioneer oil refineries in Northwestern Pennsylvania in the 1860 s. Primitive distillation techniques

More information

TC Series Cooling Systems

TC Series Cooling Systems TC Series Cooling Systems Table of Contents Table of Contents...1 List of Figures...1 Safety...2 Introduction...2 General Specifications...2 Types of Coolant...2 Routine Maintenance...2 Surge Tank Coolant

More information

Ace Heaters. Semi Instantaneous Water Heater Water-to-Water Mini-Pack TM System WW Pneumatic/Electric System Operating and Maintenance Manual

Ace Heaters. Semi Instantaneous Water Heater Water-to-Water Mini-Pack TM System WW Pneumatic/Electric System Operating and Maintenance Manual Semi Instantaneous Water Heater Water-to-Water Mini-Pack TM System WW Pneumatic/Electric System Operating and Maintenance Manual Table of Contents Page 3 Operating and Installation Instruction 4 The Mini-Pack

More information

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve High Performance in a Competitive Package ZERO Leak Technology Non-Binding Trim Design Quick, Easy Maintenance 5/1 Version 3 Product Information

More information

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR FD2 1 E 02/2000 1 Introduction As isolating valve in the main steam line of nuclear power stations different designs are known. Beside

More information

WARCO CHEMAG SERIES GH FILTERS

WARCO CHEMAG SERIES GH FILTERS WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System.

More information

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS PAGE : 1 / 13 4. PRESSURISER 4.1. DESCRIPTION The pressuriser (PZR) is a pressurised vessel forming part of the reactor coolant pressure boundary (CPP) [RCPB]. It comprises a vertical cylindrical shell,

More information

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8 , Chapter 8 as amended by CCR, Title 19 Page 1 of 8 Address: City: Date of Pump Test: Shaft Orientation: Horizontal Vertical Annual Fire Pump Test Results Number of pumps at this location: If multiple

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual Automated Fuel Maintenance System MODEL FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 03/01/2011 Rev B - Fuel Technologies - FTI-2.8 OPERATIONS & MAINTENANCE CONTENTS Installation

More information

Low fuel pressure will damage injectors 6.0 POWERSTROKE FUEL PRESSURE TESTING AND TIPS

Low fuel pressure will damage injectors 6.0 POWERSTROKE FUEL PRESSURE TESTING AND TIPS Low fuel pressure will damage injectors 6.0 POWERSTROKE FUEL PRESSURE TESTING AND TIPS WHAT CAUSES INJECTOR FAILURE This chart is from FORD. As you can see, we need to do our part to ensure the customer

More information

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with

More information

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS STEAM / HOT WATER MODELS HWG FEATURES A. O. Smith hot water generators are available for operation with steam or boiler water as the energy source. They are completely assembled with components sized,

More information

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments manuals can be found on

More information

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074

More information

Please note this is a condensed catalog. For a complete version, contact Velan directly.

Please note this is a condensed catalog. For a complete version, contact Velan directly. Please note this is a condensed catalog. For a complete version, contact Velan directly. VELAN VALVES IN POWER With an installed base covering over 300 nuclear power plants and over 2,000 thermal power

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Packaged Design Day Tank Systems

Packaged Design Day Tank Systems Fuel Supply Systems Packaged Design Day Tank Systems for diesel/fuel oil application providing a reliable fuel source for diesel and turbine engine driven equipment and oil fired boilers model & accessory

More information

Diesel Engines for Fire Protection Applications

Diesel Engines for Fire Protection Applications Cincinnati, Ohio USA - Glasgow, Scotland UK Diesel Engines for Fire Protection Applications Based on NFPA 20 2010 Edition www.clarkefire.com NFPA 20 Engine Type Diesel Engines for fire pump drive shall

More information

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2 to 1 1/2 add 2 1/2 to 'C' dimension. 428 Jones Boulevard Limerick Airport Business Center Pottstown, PA 19464 Phone: (610)495-5131 ax: (610)495-5134 www.watsonmcdaniel.com PAGE 28 INSTRUCTION PART NO. 2315400 C.R.3500 REV. 10 SIZE C B CENTER

More information

Mizer Single Pump and Starter Box

Mizer Single Pump and Starter Box Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...

More information

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting PAGE 1 This document outlines questions to ask and components to check during TES troubleshooting. More detailed troubleshooting procedures are available in the TES Troubleshooting Guide. 1. Flow Light

More information

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP A range of high pressure turbine bypass valves that provide greater reliability under extreme conditions. FEATURES Pressure reduction by multi-stage controlled expansion Atomizing steam desuperheater,

More information

Safety Considerations

Safety Considerations Safety Considerations The following safety rules MUST BE FOLLOWED to ensure safety in the laboratory. General Considerations No smoking, eating or drinking in the laboratory. Hydraulic oil in its vapor

More information

OPERATION AND INSTALLATION

OPERATION AND INSTALLATION OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over

More information

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators ENTEC WEST, INC. Spare Parts List EW-3500-C and D EW-4200-C and D Marine Diesel Generators Every generator produced by Entec West, Inc. has been recorded in a master computer file by serial number. This

More information

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5 PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5 STEP #1. MOUNTING 1. Choose a location where the unit is visible to the machine operator. 2. Locate the unit out of

More information

Operating and Installation Instructions

Operating and Installation Instructions Model Number 40401-c (-sp) Electronic Fuel Pump Operating and Installation Instructions This Product is Patent Pending. Application available upon request CAUTION! This product is to be installed only

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide diesel - gasoline - LPG P/N 0172021 June 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains

More information

HP COOL TECH, INC. COOLANT PUMP. PowerPump. OPREATIONS MANUAL Series 10000/11000

HP COOL TECH, INC. COOLANT PUMP. PowerPump. OPREATIONS MANUAL Series 10000/11000 HP COOL TECH, INC. COOLANT PUMP PowerPump OPREATIONS MANUAL Series 10000/11000 1 TABLE OF CONTENTS Page Topic 3 Introduction 3 Specifications 3 Warning 4 Safety 5 Use 6 Filter Replacement Procedure 7 Operator

More information

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011 -

More information