Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
|
|
- Mavis Todd
- 6 years ago
- Views:
Transcription
1 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Bldg 3, Rm RM6 Contact: Gareth Williams Environmental Test Centre Tel: +44 (0) MoD Shoeburyness Fax: +44 (0) Southend-on-Sea Essex Website: SS3 9XJ Testing performed at the above address only DETAIL OF ACCREDITATION Hazardous items including but not limited to: Ammunition Explosives and Propellants ENVIRONMENTAL TESTS Environmental Testing, particularly on dangerous substances under the subdivisions of the Explosives Class 1 of the UN Dangerous Goods Classification system: Climatic Testing: Firearms 1350 kg HD 1.1 Fuses: Weapons 1350 kg HD Missile Components 2000 kg HD Missiles: Guided 3000 kg HD 1.3 Missiles: Unguided Unlimited HD 1.4 Rocket Motors Weapons and Sub-assemblies Dynamic Testing: Aerospace Components and 1000 kg HD 1.1 Equipment 1000 kg HD kg HD Non-hazardous items including 2000 kg HD 1.3 but not limited to: Unlimited HD 1.4 Deviations from prescribed standards are permitted. Subject to agreement under the terms of a documented contract review with the customer and using approved procedures, providing the tests still lie within the limits of accredited tests described in this schedule and are reported accordingly. Aerospace Structures Radiographic Inspection: Casting 400 kg HD 1.1 Compressors 250 kg HD Computers, Peripherals and other 1000 kg HD IT Equipment 2000 kg HD 1.3 Electrical/Electronic Components Unlimited HD 1.4 Connectors and Products Generators: Electrical Power and Welding Hydraulic Equipment and fittings Marine Equipment Medical/Dental Equipment Assessment Manager: RC3 Page 1 of 9
2 Office Equipment: Electrical and Climatic: Single Parameters: Mechanical Radar Equipment High Temperature: Radio and TV Equipment Iss 3, 1999: CL1 & CL2 Safety Equipment and Appliances Max Temperature: + 80 C Iss 4, 2006: CL1 & CL2 Security Equipment Sonar Equipment Max Chamber Size: E, 1989: 501 Telecommunications Equipment 2.5 m x 3.0 m x 9.0 m F, 2000: 501 G, 2010: 501 Max Temperature + 75 C 302 Max Chamber Size: 2.3 m x 3.35 m x 9.3 m 2007: -2-2: Bb Low Temperature: Iss 3, 1999: CL5 Min Temperature: - 60 C Iss 4, 2006: CL5 Max Chamber Size: E, 1989: m x 3.0 m x 9.0 m F, 2000: 502 G, 2010: : -2-1: Ab 2007: -2-1: Ab Humidity: - Steady State Iss 3, 1999: CL C to + 80 C Iss 4, 2006: CL7 Humidity Range: E, 1989: % RH to 95% RH F, 2000: 507 G, 2010: 507 Max Chamber Size: 2.5 m x 3.0 m x 9.0 m : -2-78: Cab Assessment Manager: RC3 Page 2 of 9
3 Climatic: Single Parameters: (cont d) Iss 3, 1999: CL6 Humidity: - Cyclic Iss 4, 2006: CL6 Temperature Range: E, 1989: C to + 80 C F, 2000: 507 G, 2010: 507 Humidity Range: 10% RH to 95% RH : -2-1: A Max Chamber Size: 2.5 m x 3.0 m x 9.0 m Pressure, Low: Iss 3, 1999: CL21 Minimum pressure: 3.4 kpa (34mb) Iss 4, 2006: CL21 (equivalent altitude 23760) E, 1989: 500 (I & II) Maximum chamber size: F, 2000: 500 (I & II) 2.2 m x 2.2 m x 5.1 m G, 2010: 500 (I & II) : : Water - mist: : Iss 3, 1999: CL26 Maximum Plan Area 3.0 m x 4.0 m Iss 4, 2006: CL26 Water rain Maximum Plan Area: 3.0 m x 4.0 m Iss 3, 1999: CL27 Iss 4, 2006: CL27 Method 310 Procedure I Assessment Manager: RC3 Page 3 of 9
4 Climatic: Single Parameters: (cont d) Water - immersion only Iss 3, 1999: CL29 Iss 4, 2006: CL29 Pressure over water - maximum simulated depth 65 m E, 1989: 512 F, 2000: 512 Tank size: G, 2010: m x 0.7 m x 0.6 m (deep) 2001: -2-18: Rc Water - sealing Iss 3, 1999: CL30 Iss 4, 2006: CL30 Tank size: 0.6 m x 0.6 m x 1.2 m (long) 1995: Icing: Iss 3, 1999: CL10 (A) Maximum chamber size: Iss 4, 2006: CL10 (A) 2.0 m x 2.0 m x 4.0 m (high) E, 1989: 521 F, 2000: 521 G, 2010: Salt Corrosive Atmospheres: Salt Mist Iss 3, 1999: CN2 Maximum Plan Area: 3.0 m x 4.0 m Iss 4, 2006: CN2 1996: -2-52: Assessment Manager: RC3 Page 4 of 9
5 Climatic: Single Parameters: (cont d) Contamination: Fluid Iss 3, 1999: CN4 Maximum Temperature: + 80 C Iss 4, 2006: CN4 Maximum Conditioning Chamber E, 1989: 504 Size: 1.8 x 1.8 x 2.3 m (high) F, 2000: 504 G, 2010: : -2-74: Xc Contamination: Dust & Sand Maximum Chamber size: Iss 3, 1999: CL m x 1.2 m x 1.2 m (high) Iss 4, 2006: CL25 Number of delivery ducts: 2 E, 1989: 510 F, 2000: 510 Duct size (each): G, 2010: m x 0.48 m (high) 313 Temperature range: 1996: C to + 40 C Maximum Air Velocity 18 m/s Thermal Shock: Iss 3, 1999: CL14 Procedure A Maximum Temperature: +80⁰C Iss 4, 2006: CL14 Procedure A Minimum Temperature: -60⁰C E, 1989: F, 2000: Maximum Chamber Sizes: G, 2007: Cold 2.5m x 3.0m x 9.0m and Hot 2.3m x 3.35m x 9.3m : -2-14: Na Assessment Manager: RC3 Page 5 of 9
6 Rapid Decompression Minimum pressure: 3.4kPa (34mb) Iss 3, 1999: CL9 (Rapid) (equivalent altitude 23,760m) Iss 4, 2006: CL9 (Rapid) Maximum chamber size: E, 1989: 500 (Proc III) 380 mm x 380 mm x 1100 mm F, 2000: 500 (Proc III) G, 2010: (Proc III) Climatic: combined parameters: Temperature/Low Pressure Iss 3, 1999: CL11, 12,13 Temperature range: Iss 4, 2006: CL11, 12,13-60 C to + 80 C E, 1989: 500 Minimum Pressure: 3.4 kpa (34 mb) F, 2000: 500 (equivalent altitude m) G, 2010: 500 Maximum chamber size: m x 2.2m x 5.1m 1999: : Assessment Manager: RC3 Page 6 of 9
7 Vibration: modes of (Single or Twin Vibration Systems) Iss 3, 1999: M1, M2, M3 Sinusoidal Iss 4, 2006 M1, M2, M3 Random Narrow band Random-on-Random E, 1989: 514, 519 Sine-on-Random F, 2000: 514.5, Swept Sine-on-Random G, 2010: 514.6, Gunfire Time History Replication 401, 405 Classical Shock Pulses Bump 1996: -2-6: Fc Restrained Cargo 2008: -2-6: Fc 2000: -2-50: Z/AFc Electro-Dynamic capabilities: 2000: -2-51: Z/BFc total 6 systems 2010: : -2-57: Ff Maximum values: 2013: -2-57: Ff 1993: -2-59: Fe Thrust: 160kN - Sine 1995: kN - Random 2008: Frequency Range: - 5 to 3000Hz 2005: -2-80: Fi Displacement: 50.8mm pk-pk (Shock) 38mm pk-pk Load Support: Header 1363kg Load Bearing Platform. 3500kg Temperature Conditioning: - 60 C to + 90 C Thermal Enclosure:approximately 2m x 2m x 6m Shock (free fall): modes of Iss 3, 1999: M3, M6, M7 Half Sine Iss 4, 2006 M3, M6, M7 Trapezoidal E, 1989: 516 Terminal Peak Sawtooth F, 2000: 516 Free fall shock capabilities: G, 2010: 516 Systems Maximum values: 403 Half Sine: 200 g - Load 1360 kg Table size 1.5 m x 1.5 m 2009: Trapezoidal : 2003: g - Load 1360 kg - Table size 1.5 m x 1.5 m Temperature Pre-Conditioning: - 60 C to + 60 C Assessment Manager: RC3 Page 7 of 9
8 Impact - Vertical & Horizontal Free fall: total 3 Systems Horizontal Impact: total 1 System Iss 3, 1999: M5, M11 Iss 4, 2006 M5, M11 Maximum values: Vertical Impact: Drop Height: 15m 413 (I & II) Item Mass: 2,400kg Size of Drop Plate: 2m x 3m 1997: : Horizontal Impact: Item Mass: 1940kg Impact Surface: Steel Plate Plate Size: 1.5m x 3.0m Bounce Maximum Mass: 2700kg Maximum size: 3.0m x 1.75m Temperature Pre-Conditioning: - 60 C to + 90 C for All Impact - Vertical & Horizontal and Bounce Climatic / Dynamic - Combined Parameters Temperature / Vibration / Shock Iss 3, 1999: M1 Iss 4, 2006 M1 Maximum Test Parameters: E, 1989: Temperatures: - 60 C to + 90 C F, 2000: G, 2010: Thermal Enclosure: 2.0 m x 2.0 m x 6.0 m 401, : -2-50: Z/AFc 2000: -2-51: Z/BFc 2010: : -2-6: Fc 2009: : : : -2-80: Fi Assessment Manager: RC3 Page 8 of 9
9 Radiographic Inspection: Documented 'In-house' methods to suit the customers requirements X-Ray - Static: 320keV (based on BS EN 444:1994 and related specifications) X-Ray - Mobile: 300keV Linear Accelerator: 6MeV END Assessment Manager: RC3 Page 9 of 9
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK High Post Contact: Enquiries +44 (0)1722 411611 Salisbury Tel: +44 (0)1722 428739 Wiltshire Fax: +44 (0)1722 428794 SP4 6AS E-Mail: ian.callender@chemringcm.com
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Environmental Engineering Department PB 500 PO Box 19 Six Hills Way Stevenage Hertfordshire SG1 2DA Contact: Mr V Patel/Mr S Warner Tel: +44 (0)1438 752857/752873 Fax: +44 (0)1438 753130 E-Mail: simon.warner@mbda-systems.com
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Unit 1 Quatro Park Paycocke Road Basildon Essex SS14 3GH Contact: Mr E Martin Tel: +44 (0)1268 290115 Fax: +44 (0)1268 290123 E-Mail: eamonn.martin@mira.co.uk
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Stratford Road Solihull West Midlands B90 4GW Contact: Mr C Gregory Tel: +44 (0)121 627 3225 Fax: +44 (0)121 627 4353 E-Mail: colin.gregory@trw.com Website:
More informationENVIRONMENTAL TESTING
ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431
More informationETSI EN V2.1.2 ( )
European Standard (Telecommunications series) Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-1: Specification of environmental tests; Storage 2 Reference
More informationDraft ETSI EN V2.1.6 ( )
Draft EN 300 019-2-1 V2.1.6 (2014-06) European Standard Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-1: Specification of environmental tests; Storage 2
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel
More informationDraft ETSI EN V2.3.7 ( )
Draft EN 300 019-2-3 V2.3.7 (2015-09) EUROPEAN STANDARD Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
(part of Smithers Rapra and Ltd) Packaging Technical Services Cleeve Road Leatherhead Surrey KT22 7RU Contact: Mr G Collis Tel: +44 (0)1372 802000 Fax: +44 (0)1372 802245 E-Mail: gcollis@smithers.com Website:
More informationETSI EN V2.3.1 ( )
EN 300 019-2-2 V2.3.1 (2013-04) European Standard Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-2: Specification of environmental tests; Transportation 2
More informationETSI EN V2.2.2 ( )
EN 00 019-2- V2.2.2 (200-04) European Standard (Telecommunications series) Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-: Specification of environmental
More informationFinal draft ETSI EN V2.2.1 ( )
Final draft EN 00 019-2- V2.2.1 (2002-11) European Standard (Telecommunications series) Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-: Specification of
More informationETSI EN V3.0.0 ( )
EN 300 019-2-6 V3.0.0 (2002-12) European Standard (Telecommunications series) Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-6:
More informationHuntsville- Aerospace Testing & Engineering Services Highway 20 West Huntsville, AL 35806
Huntsville- Aerospace Testing & Engineering Services 7800 Highway 20 West Huntsville, AL 35806 Facility Overview Huntsville Facility Overview Site: Total Square Footage: 92 Acres 160,000 sq. ft. of Laboratory
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Larry Brooks (QA Manager) Phone: 630 495 9770 ext. 166 Email: lbrooks@elitetest.com
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11321-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.12.2016 to 19.12.2021 Holder of certificate: TÜV
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 6 Prenton Way Contact: Dr J Roberts North Cheshire Trading Estate Tel: +44 (0)151 649 9955 Prenton Fax: +44 (0)151 649 9977 Wirral E-Mail:
More informationSPECIFICATION FOR BATTERY, NON-RECHARGEABLE, ALKALINE MANGANESE DIOXIDE, 1.5V, NATO STOCK NO XXX-XXXX (NATO TYPE DESIGNATION NBA 3058)
4 JUNE 1984 SPECIFICATION FOR BATTERY, NON-RECHARGEABLE, ALKALINE MANGANESE DIOXIDE, 1.5V, NATO STOCK NO 6135-99-XXX-XXXX (NATO TYPE DESIGNATION NBA 3058) 1 This Supplement is to be read in conjunction
More informationDraft ETSI EN V2.3.1 ( )
Draft EN 300 019-2-4 V2.3.1 (2012-12) European Standard Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental
More informationOur test laboratory - Apparatebau Kirchheim-Teck GmbH
1 / 16 Test laboratory equipment 1 Microsection lab for crimp contacts Tensile, pressure and bending test machine: Static + dynamic Vibration test: Vibration + shock Climate tests: Temperature + humidity
More informationDraft ETSI EN V2.3.7 ( )
Draft EN 300 019-2-4 V2.3.7 (2015-09) EUROPEAN STANDARD Engineering (EE); conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary
More informationEMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai
Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Stephen Laya (QA Manager) Phone: 630 495 9770 ext. 119 Email: sglaya@elitetest.com
More informationHigh Current Thermal Fuse
High Current Thermal Fuse FEATURES Functioning temperature: F = (235 ± 15) C Holding temperature: H = 160 C Current: 50 A Suitable for insert assembly systems Material categorization: For definitions of
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12095-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2015-07-16 to 2019-03-06 Holder of certificate: Weidmüller
More informationAPS 420 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5
Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 The APS 420 ELECTRO-SEIS shaker is a long stroke, electrodynamic force generator specifically designed to be used alone or in arrays for studying
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11272-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 18.10.2017 to 17.10.2022 Holder of certificate: VDZ
More informationCAN and Serial Instrumentation
Instrumentation Models 3140 and 3141 www.curtisinstruments.com 1 Curtis Models 3140 and 3141 are designed to display critical vehicle and motor controller data in an easy-to-read and attractive LCD. The
More informationQuality Product and Package Testing
TM WESTPAK, INC. Locations: 83 Great Oaks Boulevard San Jose California 95119 Phone: 408.224.1300 Fax: 408.224.5113 10326 Roselle Street Suite 101 San Diego California 92121 Phone: 858.623.8100 Fax: 858.623.8101
More informationAPS 113 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5
Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 The ELECTRO-SEIS shaker is a long stroke, electrodynamic force generator specifically designed to be used alone or in arrays for studying dynamic
More informationCHAPTER 6 ENVIRONMENTAL CONDITIONS
ENVIRONMENTAL CONDITIONS 6.1 Summary This chapter introduces the natural environment of launch site, thermal environment during SC operation, thermal and mechanical environments (vibration, shock & noise)
More informationPRODUCT RELIABILITY TESTING: Environmental, Mechanical and Packaging Case study: 19 Rackmount Switch
PRODUCT RELIABILITY TESTING: Environmental, Mechanical and Packaging Case study: 19 Rackmount Switch Herb Schueneman President & CEO Presenter Mike Brown Laboratory Manager Presenter June 2015 Overview
More informationETSI EN V2.5.1 ( )
EN 300 019-2-4 V2.5.1 (2018-07) EUROPEAN STANDARD Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SGS West Thurrock Laboratory Contact: David Mercer (Laboratory Manager) 859 London Road Tel: +44 (0)1708 681943 West Thurrock Fax: +44 (0)1708
More informationAnnex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 19102 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.09.2013 to 02.09.2018 Holder of certificate: AUCOTEAM
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 ine Trees, Chertsey Lane, taines-upon-thames, TW18 3HR, UK Millbrook roving Ground Ltd Aston Way Leyland reston Lancashire R26 7TZ Contact: Ms tephanie Nixon Tel: +44 (0)1772 425911 Fax: +44 (0)1772
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey ane, Staines-upon-Thames, TW18 3HR, UK Kiwa td t/a Kiwa Gastec Kiwa House Malvern View Business Park Stella Way Bishops Cleeve Cheltenham Gloucestershire G52 7DQ Contact: Mrs Thomas
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: Unit 9 G B Quality ssurance (Consultants)
More informationSeries 80 Mighty Mouse Technical Reference Complete Product Specification
Summary Performance Specifications Current Rating (Maximum): Size #23 Contact: 5 A., Size #20 contact: 7.5 A., Size #16 contact: 13 A., Size #12 contact: 23 A. Test Voltage (Dielectric Withstanding Voltage)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV SUD AMERICA - AUBURN HILLS 1755 Atlantic Blvd. Auburn Hills, MI 48326 William (Mac) Elliott Phone: 813 284 2736 MECHANICAL Valid To: August 31, 2018 Certificate
More informationAPS 400 ELECTRO-SEIS. Long Stroke Shaker Page 1 of 5. Applications. Features
Long Stroke Shaker Page 1 of 5 The APS 400 ELECTRO-SEIS is a force generator specifically designed to be used alone or in arrays for studying dynamic response characteristics of various structures. It
More informationSystems. Dynamic Test. Electrodynamic Vibration Test Systems
Systems 100 - water 120 kn cooled Electrodynamic Vibration Test Systems SW3-10480APP (100KN) SW3-10LS3-550APP (100KN) SW3-10650APP (100KN) SW3-12480APP (120KN) SW3-12LS3-550APP (120KN) Dynamic Test Technical
More informationReport of Expert Group 8 Environmental Engineering March 2010
CEN Workshop 10 Report of Expert Group 8 Environmental Engineering March 2010 1 Composition of Expert Group 8 Convenor Mr. RICHARDS, Dave Lockheed Martin UK dave.p.richards@lmco.com UK Active Participants
More informationROLEC Gehäuse-Systeme GmbH Mr. Volker Borcherding Kreuzbreite 2 D Rinteln
Reg.-Nr. DAP PL 2812.00 Labor für Umwelterprobung und Werksffprüfung Telefon +49-3 41 / 4 84 32-25 Telefax +49-3 41 / 4 84 32-14 email umwelterprobung@tzoleipzig.de Technologie Zentrum Oberflächentechnik
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Bootham Lane Industrial Estate Bootham Lane Dunscroft Doncaster
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Issue No: 031 Issue date: 21 ugust 2018 ccredited to Unit 7 Prince William Drive
More informationCLIMATE. Climate and temperature chambers.
Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate
More informationCabinet-built single drives, ACS880-07
Cabinet-built single drives, ACS880-07 Our cabinet-built single drives are built to order, meeting customer needs despite any technical challenges. Designed on ABB's common drives architecture, this compact
More informationE280 DIAMETER FRAMES
E28 DIAMETER FRAMES MODEL NUMBER CODE...E28 FRAME To construct a motor listing, select the combination of features required, and put all the coded information in the proper sequence. Please account for
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-19125-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2015-05-11 to 2018-12-15 Holder of certificate: Institute
More informationTESTS, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE TESTS ENVIRONMENTAL AND CORROSION TESTS
, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE ENVIRONMENTAL AND CORROSION VIBRATION AND ENVIRONMENTAL MECHANICAL RESISTANCE VZLU TEST, a.s. provides a wide range of development, qualification and serial
More informationMETHOD FOR TESTING STEERABILITY AND STABILITY OF MILITARY VEHICLES MOTION USING SR60E STEERING ROBOT
Journal of KONES Powertrain and Transport, Vol. 18, No. 1 11 METHOD FOR TESTING STEERABILITY AND STABILITY OF MILITARY VEHICLES MOTION USING SR6E STEERING ROBOT Wodzimierz Kupicz, Stanisaw Niziski Military
More informationBrüel & Kjær and LDS The Perfect Match SHORT FORM CATALOGUE
Brüel & Kjær and LDS The Perfect Match SHORT FORM CATALOGUE 4 Aerospace For any aircraft, helicopter, space vehicle or ballistic device, reliability is the number one priority. By using our vibration test
More informationACOCAR active suspension
ACOCAR active suspension Bert Vandersmissen Vehicle Dynamics Expo Stuttgart, 07/05/2008 Contents Introduction Active suspension hardware Quarter car test rig Skyhook quarter car control Experimental skyhook
More informationVibration Test Systems
Vibration Test Systems Lansmont Vibration Test Systems are versatile, easy to operate, and reliable servo-hydraulic vibration testing equipment. Whether you are testing bare products, individual packages,
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More informationProportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB
Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar
More informationFROM THE SEA TO THE LANDS. OUR WORKS DOCK TO SOLVE YOUR NEEDS
FROM THE SEA TO THE LANDS. OUR WORKS DOCK TO SOLVE YOUR NEEDS Absolute expertise, absolute accuracy, absolute reliability. Nothing else. Pellegrini s name became firmly established with Italian shipyards/owners
More informationActuator LA35. Data sheet LINAK.COM/TECHLINE
Actuator LA35 Data sheet LINAK.COM/TECHLINE LA35 The LA35 is a very quiet and powerful actuator, and provides a practical and cost-effective solution with low power consumption. The actuator is designed
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK retby usiness Park Ashby Road Stanhope urton upon Trent Staffordshire DE15 0YZ Contact: Mr R M Allen Tel: +44 (0)1283 216334 Fax: +44 (0)1283
More informationAxial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof
More informationHigh temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250
Data sheet High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250 The compact heavy duty pressure transmitter type MBS 2200 and MBS 2250 are designed for use in severe
More informationPressure transmitters for heavy duty applications MBS 3200 and 3250
Data sheet Pressure transmitters for heavy duty applications MBS 3200 and 3250 The compact high temperature pressure transmitter MBS 3200 is designed for use in hydraulic and almost all industrial applications,
More information1/11 表單編號 QS-3Q B
Battery Pack Test Report UN38.3 Customer: Lenovo Pack Model: L15C4A02 Nominal voltage: 14.4V Nominal capacity: 32Wh Configuration: 4S1P Customer P/N: 5B10L04163 Celxpert P/N: 921300080 Cell Type: LG INR18650S3
More information3M CP2 Press-Fit Headers and Sockets, 2 mm
1 of 7 3M CP2 Press-Fit Headers and Sockets, 2 mm A-Style CP2 Connectors CP2-SA110-G1-KR Right Angle Socket Connectors mated to CP2-HA110-GA1-KR Header Connectors 78-5102-0083-1 Revised Date: February
More informationTEST REPORT. The following merchandise was submitted and identified by the vendor as:
Page: 1 of 13 Date: Feb 17, 2016 E-ONE MOLI ENERGY CORP. Tainan Science-Based Industry Park No.10 Dail 2nd Rd., Shan-Hwa, Tainan City, Taiwan R.O.C. Tel: 886-6-505-0666, Fax: 886-6-505-0777 http://www.molicel.com.
More informationINTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist
INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR ac ROLLER TABLE MOTORS (Second Revision) Corresponding IS does not exist IPSS:1-03-007-14 Formerly : IPSS:1-03-007-03 0. FOREWORD 0.1 This Inter
More informationConcorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-380E/44 Series
... the heart of your system. Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106 RG-380E/44 Series 24 VOLT 42.0 Ah, VALVE REGULATED, LEAD-ACID, AIRCRAFT BATTERY USER
More informationOil Coolers 2000 series
Hydraulic Oil Coolers 2000 series Installation The illustration shows the correct position of the oil and water connections for horizontal and vertical mounting to ensure that the coolers operate full
More informationSPMM OUTLINE SPECIFICATION - SP20016 issue 2 WHAT IS THE SPMM 5000?
SPMM 5000 OUTLINE SPECIFICATION - SP20016 issue 2 WHAT IS THE SPMM 5000? The Suspension Parameter Measuring Machine (SPMM) is designed to measure the quasi-static suspension characteristics that are important
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK The Old School Stillhouse Lane Bedminster BS3 4EB Contact: Dr Dimitris Xirouchakis Tel: +44 (0)117-9471000 Fax: +44 (0)117-9471004 E-Mail:
More informationQUALIFICATION TEST SUMMARY REPORT ESR Qualification Type Testing of Amphenol Corporation s 2M801 Series Connector
Page 1 of 13 QUALIFICATION TEST SUMMARY REPORT ESR-9389 Qualification Type Testing of Amphenol Corporation s Connector PREPARED BY: Patrick Cole Design Engineer AMPHENOL CORPORATION Aerospace Operation
More informationThe Multivariable Air Flow Meter
The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide
More informationTitre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION
Date: December 19 th, 16 ISSUE: 1/B PAGE: 1 / 21 Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION Rédigé par / Written by Responsabilité / Responsibility Date Signature
More informationVIA Platform Environmental Qualification Testing Standards
VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...
More informationIQLab Pack UNDOT Test Report
IQ Laboratories 508 Chundong Road Shanghai 201108 China IQLab Pack UNDOT Test Report Tested According To UN Manual of Tests and Criteria, Part III, subsection 38.3, Rev 5 Name of Sample: Rechargeable Lithium
More informationFAR FROM THE COASTS, CLOSE TO THE BEST CHOICE YOU EVER MADE
FAR FROM THE COASTS, CLOSE TO THE BEST CHOICE YOU EVER MADE Absolute expertise, absolute accuracy, absolute reliability. Nothing else. M.E.P. Pellegrini Marine Equipments proposes a complete fshore crane
More informationPressure transmitter for marine applications MBS 3100 and MBS 3150
Data sheet Pressure transmitter for marine applications MBS 3100 and MBS 3150 The compact ship approved pressure transmitters MBS 3100 and MBS 3150 are designed for use in almost all marine applications.
More information4.Test Requirements: No mass loss,no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%.
: : : : : : 1.Test Item: Altitude simulation (T1) 2.Test Purpose: This test simulates air transport under low-pressure conditions. Test cells and batteries shall be stored at a pressure of 11.6kPa or less
More informationTRANSPORT OF DANGEROUS GOODS
Recommendations on the TRANSPORT OF DANGEROUS GOODS Manual of Tests and Criteria Fifth revised edition Amendment 1 UNITED NATIONS SECTION 38 38.3 Amend to read as follows: "38.3 Lithium metal and lithium
More informationE180 DIAMETER FRAMES
E18 DIAMETER FRAMES MODEL NUMBER CODE...E18 FRAME To construct a motor listing, select the combination of features required and put all the coded information in the proper sequence. Please account for
More informationControlled Power Technologies. COBRA FC Water Cooled Electric Compressor (Fuel Cell Air Supply)
Controlled Power Technologies COBRA FC Water Cooled Electric Compressor (Fuel Cell Air Supply) COBRA FC Water Cooled Electric Compressor Fuel Cell Air Supply COBRA (Controlled Boosting for Rapid response
More informationThe Multivariable Air Flow Meter
No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F
More informationHigh Performance Thermal-Magnetic Circuit Breakers 410/520/
High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism
More informationTechnical specification
See iorr- Technical specification SNO. DESCRIPTION UNIT I QTY 1 Hydraulic Snubber with Total stroke 140mm, working stroke 80mm, length NOS 10 at half stroke 49Rmm, dia 84mm and maximum load level] 7.5
More informationLOW RECOIL, HEAT TRANSFER MITIGATING RAREFACTION WAVE GUN ENGINEERING, MODELING AND LARGE CALIBER SYSTEM DEMONSTRATOR DEVELOPMENT
LOW RECOIL, HEAT TRANSFER MITIGATING RAREFACTION WAVE GUN ENGINEERING, MODELING AND LARGE CALIBER SYSTEM DEMONSTRATOR DEVELOPMENT BRIEFING FOR THE NDIA GUNS AND MISSILE SYSTEMS CONFERENCE - APRIL 23 26,
More informationCHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER
CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER 1. Scope : This Chapter describes the methods to measure the resistance to the progress
More informationZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket
Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in
More informationPressure transmitter for marine applications MBS 33M
Data sheet Pressure transmitter for marine applications MBS 33M The standard pressure transmitter MBS 33M is designed for use in almost all marine applications, and offers a reliable pressure measurement,
More informationSEP 2016 Rev D2
Product Specification 108-2112 28 SEP 2016 Rev D2 VAL-U-LOK* Connectors 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for VAL-U-LOK* Connectors. 1.2. Qualification
More information56 mm sq. (2.20 inch sq.)
56 mm sq. (2.2 inch sq.) 1.8 /step RoHS Bipolar winding, Lead wire type Unipolar winding, Lead wire type p. 68 Customizing Hollow Shaft modification Decelerator Encoder Varies depending on the model number
More informationUltrasonic Flow Meter Series Smart-IN US. Features. Description
Features Series 7200 is single-board, self-contained and state-of -the-art ultrasonic flow meter. It has the notable characteristics of high precision, high reliability, high performance, low price etc..
More informationTECHNICAL DATA SHEET AIRCRAFT GROUND POWER UNIT MODEL NO. B809D-1
COGNIZANT SERVICE: U.S.A.F. NATIONAL STOCK NUMBER: 6115-01-502-7927 OVERALL DIMENSIONS AND WEIGHT: Height: 63 Inches Length: 103 Inches Width: 66 Inches Weight (Dry): 4,372 Lbs. FUNCTIONAL DESCRIPTION:
More informationAstm E83. Astm E83
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with astm e83. To get started
More informationZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits
Technical Datasheet 1SNK1107D001 Catalogue Page 1SNK1107S001 ZS4-T Screw Clamp Terminal Blocks Triple deck with feed-through circuits Save space: independent circuits in just. mm 0.0 in spacing, - Fit
More informationZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral
Technical Datasheet SNK6047D00 Catalogue Page ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Simplify your PE.N connection with ZS35-PE block connected to ZS35-BL through a premounted jumper. SNK6063F004
More informationUN Test Report. - ASM P/N SB10F46442(Nom.36Wh, 7.4V)-
문서번호 Prepared Reviewed Approved QAE-EF02-140325-PKASM P/N SB10F46442 남익현장승현남대호박해나김병수 UN Test Report - ASM P/N SB10F46442(Nom.36Wh, 7.4V)- 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test
More informationConcorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106
Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106 RG-500 and RG-600 Series 24 VOLT 17 Ah, VALVE REGULATED, LEAD-ACID, AIRCRAFT BATTERY DECLARATION OF DESIGN PERFORMANCE
More information