ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Size: px
Start display at page:

Download "ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY"

Transcription

1 ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the information, products, services, or related graphics contained in the document for any purpose. Any reliance placed on such information is therefore strictly at your own risk. ABB reserves the right to discontinue any product or service at any time. Copyright 2018 ABB. All rights reserved. 9AKK107045A

2 MAY 2018 Order sheet

3 2 PORCELAIN BUSHINGS (MEDIUM/LOW ) ORDER SHEET Technical data Catalogue tandard Rated Nominal Dry Power Creepage Arcing MIN Lee current Voltage lightning frequency distance Distance Protected Line A kv kv kv kv mm mm mm 1/250 DIN A1 DIN /250 DIN A1 DIN /630 DIN A1 DIN /630 DIN A1 DIN /1000 DIN A2 DIN /1000 DIN A2 DIN /2000 DIN A2 DIN /2000 DIN A2 DIN /3150 DIN A2 DIN /3150 DIN A2 DIN /250-A A3 EN /250-B A4 EN /630-A A5 EN /630-B A6 EN /1250-A A7 EN /1000-B A8 EN /1250-B A8 EN /2000 A9 EN /3150 A9 EN /4000 A9 EN /5000 A9 EN /4500 A10 COMEM /6500 A11 COMEM LV - LOW

4 ORDER SHEET PORCELAIN BUSHINGS (MEDIUM/LOW ) 3 Technical data Catalogue Standard Rated Nominal Dry Power Creepage Arcing Pollution current Voltage lightning frequency distance Distance level A kv kv kv kv mm mm 12/250-P1 B5 EN P1 12/250-P2 B5 EN P2 12/250-P4 B5 EN P4 24/250-P2 B5 EN P2 24/250-P3 B5 EN P3 24/250-P4 B5 EN P4 36/250-P1 B5 EN P1 36/250-P3 B5 EN P3 36/250-P4 B5 EN P4 12/630-P3 B6 EN P3 12/630-P4 B6 EN P4 24/630-P2 B6 EN P2 24/630-P4 B6 EN P4 36/630-P2 B6 EN P2 36/630-P4 B6 EN P4 12/1250-P4 B7 EN P4 24/1250-P3 B7 EN P3 24/1250-P4 B7 EN P4 36/1250-P3 B7 EN P3 36/1250-P4 B7 EN P4 12/2000-P4 B7 EN P4 24/2000-P3 B7 EN P3 24/2000-P4 B7 EN P4 36/2000-P3 B7 EN P3 36/2000-P4 B7 EN P4 12/3150-P4 B7 EN P4 24/3150-P3 B7 EN P3 24/3150-P4 B7 EN P4 36/3150-P3 B7 EN P3 36/3150-P4 B7 EN P4 MV - MEDIUM

5 4 PORCELAIN BUSHINGS (MEDIUM/LOW ) ORDER SHEET Technical data Catalogue Standard Rated Nominal Dry Power Creepage Arcing Pollution current Voltage lightning frequency distance Distance level A kv kv kv kv mm mm 52/1250-P1 B13 EN P1 52/2000-P1 B13 EN P1 52/3150-P1 B13 EN P1 52/1250-P3 B13 EN P3 52/2000-P3 B13 EN P3 52/3150-P3 B13 EN P3 52/1250-P4 B13 EN P4 52/2000-P4 B13 EN P4 52/3150-P4 B13 EN P4 24/5000-P2 B15 EN P2 24/8000-P2 B15 EN P2 24/5000-P4 B15 EN P4 24/8000-P4 B15 EN P4 36/5000-P2 B15 EN P2 36/8000-P2 B15 EN P2 36/5000-P3 B15 EN P3 36/8000-P3 B15 EN P3 MV - MEDIUM Catalogue Standard Rated Nominal Dry Power Creepage Arcing MIN Lee current Voltage lightning frequency distance Distance Protected Line A kv kv kv kv mm mm mm 36/250 B8 COMEM /250 B9 COMEM /630 B9 COMEM /6300 B10 COMEM /4500 B11 COMEM /4500 B11 COMEM /4500 B11 COMEM /1000 B12 COMEM /2000 B12 COMEM /3150 B12 COMEM MV - MEDIUM

6 ORDER SHEET PORCELAIN BUSHINGS (MEDIUM/LOW ) 5 Technical data Catalogue Standard Rated Nominal Dry Power Creepage Arcing Pollution current Voltage lightning frequency distance Distance level A kv kv kv kv mm mm 12/250 DIN B1 DIN /250 DIN B1 DIN /250 DIN B1 DIN /630 DIN B2 DIN /630 DIN B2 DIN /630 DIN B2 DIN /1000 DIN B3 DIN /1000 DIN B3 DIN /1000 DIN B3 DIN /2000 DIN B3 DIN /2000 DIN B3 DIN /2000 DIN B3 DIN /3150 DIN B3 DIN /3150 DIN B3 DIN /3150 DIN B3 DIN /1000 DIN B4 DIN /2000 DIN B4 DIN /3150 DIN B4 DIN /5000 DIN B14 DIN /8000 DIN B14 DIN /5000 DIN B14 DIN /8000 DIN B14 DIN MV - MEDIUM

7 6 PORCELAIN BUSHINGS (MEDIUM/LOW ) ORDER SHEET Porcelain bushings (Low Voltage) Order specification sheet Date Rev. Customer reference Electrical features Nominal voltage Rated current kv A Relevant standard DIN EN Comem Other Active parts in air Tinned 10 micron Silver-plated 3 micron Other Catalogue page A Gasket NBR VITON FVMQ (Fluorosilicon) Special Terminal contact in the lower part A Notes B (1) Customer drawing (1) According to EN strandard type B is applied to: Brass bolt: 1kV/250A, 1kV/630A, 1kV/1000A, 1kV/1800A Copper bolt: 1kV/1250A, 1kV/2000A B Terminal contact in the upper part A B Customer drawing No need Notes Notes (Construction details according to customer specifications):

8 ORDER SHEET PORCELAIN BUSHINGS (MEDIUM/LOW ) 7 Porcelain bushings (Medium Voltage) Order specification sheet Date Rev. Customer reference Electrical features Nominal voltage Rated current Creepage distance kv A mm Relevant standard DIN EN Comem Other Active parts in air Tinned 10 micron Silver-plated 3 micron Other Fixing components Galvanized Stainless steel Flange Aluminium Galvanized Gasket (1) NBR VITON FVMQ (Fluorosilicon) Special (1) The gasket between porcelain and tank will be always in rubber cork if not differently specified in the notes Catalogue page B Dimension (mm) Arcing horns Yes No Accessiories for lower part Flag Customer drawing Accessiories for upper part Flag Customer drawing Notes (Construction details according to customer specifications):

Pressure Relief Device Comem PRD Order sheet

Pressure Relief Device Comem PRD Order sheet J U N E 2 017 Pressure Relief Device Comem PRD Order sheet ABB SpA COMEM Operating Unit Power Grids Division Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY The information contained

More information

INSTRUCTION MANUAL CRS Combined insulation bushing

INSTRUCTION MANUAL CRS Combined insulation bushing INSTRUCTION MANUAL CRS Combined insulation bushing 5COH020200 CRS REV03 2 TABLE OF CONTENTS 1 SAFETY... 5 1.1 SAFETY INSTRUCTION... 5 1.2 SPECIFIED APPLICATION... 5 1.3 SAFETY NOTES ON THE EQUIPMENT OPERATION...

More information

BUSHINGS: GENERAL INFORMATION

BUSHINGS: GENERAL INFORMATION BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency

More information

PORCELAIN BUSHINGS ED Series

PORCELAIN BUSHINGS ED Series PORCELAIN BUSHINGS ED Series An innovative design: the most popular and most reliable 1 kv bushing on the market www.cedaspe.com LV BUSHINGS ED by CEDASPE CEDASPE is happy to present a complete new family

More information

Bushing Insulators according to DIN and UNEL Standards

Bushing Insulators according to DIN and UNEL Standards Bushing Insulators according to DIN and UNEL Standards Description and general specifications Outdoor transformer bushing DIN 42532 and UNEL 38159/74 rated current 630A Bushing EN 50180 12-24-36/630-1250-2000-3150

More information

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03 INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00 INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

Outdoor Bushings DIN kv / A Freiluft Durchführungen DIN kv / A

Outdoor Bushings DIN kv / A Freiluft Durchführungen DIN kv / A Outdoor Bushings DIN 0 kv / 0-0 A Freiluft Durchführungen DIN 0 kv / 0-0 A Qty. 0 Top porcelain A Bottom porcelain B Brass stem Brass washer E Brass washer G Ring gasket J Plain gasket (M) Flange gasket

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Type IMC Indoor current transformer

Type IMC Indoor current transformer Instrument transformers Type IMC Indoor current transformer Product features 600 volt indoor 10 kv BIL 25 through 400 Hertz amperes: 50-1000 2.5" (64 mm) round window Designed for variable applications

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Spare Parts

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Spare Parts 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Spare Parts SafeGear Motor Control Center Arc resistant Metal-Clad construction Lamps & buttons YMN -074063P0212 YMN -074063P0412

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Type ICX Outdoor open type cutout

Type ICX Outdoor open type cutout Distribution cutouts Type IC Outdoor open type cutout Product features 7.8 kv, 15 kv, 15/27 kv, 27 kv, or 38 kv on 100 A 7.8 kv, 15 kv, and 15/27 kv only on 200 A 110, 125, 150, 170, or 180 kv BIL 180

More information

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper GE Grid Solutions PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper PNO bushings are capacitance graded bushings with an oil impregnated paper core. PNO bushings are conform

More information

Transformer bushings, type GSA-OA Technical guide

Transformer bushings, type GSA-OA Technical guide Transformer bushings, type GSA-OA Technical guide ZSE 2750- en, Rev. 5, 2005-05-5 This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to

More information

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer bushings, type GOA 250. Installation and maintenance guide Transformer bushings, type GOA 250 Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor

More information

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide 1ZSE 2750-111 en, Rev. 9 Transformer bushings, type GSA-OA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Bushings for High Voltage AC Applications

Bushings for High Voltage AC Applications Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure

More information

Advance 27 ANSI 27 kv switchgear

Advance 27 ANSI 27 kv switchgear Advance 27 ANSI 27 kv switchgear Table of contents Advance 27...3 AMVAC breaker...4 Instrument transformers...5 Current transformers...5 27 kv voltage transformers...6 Distribution protection and control...7

More information

How to take advantage of the growing demand for intelligent solar solutions

How to take advantage of the growing demand for intelligent solar solutions How to take advantage of the growing demand for intelligent solar solutions The intelligent solar boom The demand for solar energy in residential installations is on the rise and has been for some time.

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SafeGear TM Motor Control Center Arc resistant metal-clad construction SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor

More information

Inductive voltage transformers

Inductive voltage transformers Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They

More information

Inductive voltage transformers

Inductive voltage transformers Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They

More information

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY PABS Air-to-SF 6 Bushings 7.5-800 kv BUSHINGS AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS 7 - ANSI STANDARDS AN ALSTOM COMPANY PABS bushings are gas-insulated types that meet IEC 7, ANSI/IEEE or

More information

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear Descriptive bulletin ReliaGear ND ANSI narrow frame metal-clad switchgear Table of contents Introduction...3 Vmax/A breaker...4 Instrument transformers...5 Potential transformers...6 15 kv potential transformers...6

More information

SERIES TAP-CHANGER

SERIES TAP-CHANGER SERIES 090 - TAP-CHANGER Main characteristics This is an off-circuit tap changer. It means DO NOT OPERATE WHILE THE TRANSFORMER IS ENERGISED. Main characteristics of this tap-changer series are: dimensional

More information

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin Contents 1. Introduction 2 2. Product highlights 2 3. Available configuration/competitive

More information

General catalogue Epoxy resin and silicon rubber insulators

General catalogue Epoxy resin and silicon rubber insulators General catalogue Epoxy resin and silicon rubber insulators 1 2 Contents Introduction 02 Insulators for indoor use 04 Insulators for outdoor use 27 Products for SF6 insulated switchgear 39 1 Introduction

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin SafeGear Motor Control Center Arc resistant Metal-Clad construction Descriptive Bulletin Table of Contents

More information

INSTRUCTION MANUAL Oil level with pointer indicator

INSTRUCTION MANUAL Oil level with pointer indicator INSTRUCTION MANUAL Oil level with pointer indicator 5COL868200 REV.B I II CONTENTS 1. SAFETY... 1 1.1 Safety instructions... 1 1.2 Specified applications... 1 1.3 Safety notes on the equipment operation...

More information

Transformers Global product offering

Transformers Global product offering Distributor Line Card Transformers Global product offering ABB is a major transformer manufacturer throughout the world and offers both liquid-filled and dry-type transformers as well as services for complete

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market

OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market OTAA The OTAA is the next generation of Oil Impregnated Paper condenser bushing manufactured to IEEE C57.19.01 from 25 kv to 500 kv system

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

Inductive voltage transformers

Inductive voltage transformers Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They

More information

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv 3EP1 Surge Arrester Metal-oxide surge arrester without series gaps for high-voltage systems up to U m = 170 kv Rated voltage up to 180 kv Nominal discharge current 10 ka, 8/20 µs Line discharge class LD1,

More information

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT. PowerIT PowerIT Indoor Voltage Transformer Fuses, WBP Outdoor Voltage Transformer Fuses, BRT Catalogue 1YMB612070-en Industrial IT enabled TM 1. FEATURES Unlimited breaking capacity Short circuit current

More information

BHATINDA CERAMICS PRIVATE LIMITED (Mfrs/Exporters of High Tension Porcelain Insulators)

BHATINDA CERAMICS PRIVATE LIMITED (Mfrs/Exporters of High Tension Porcelain Insulators) (Mfrs/Exporters of High Tension Porcelain Insulators) Regd. (O) & Works:- Vill. Jodhpur Romana Dabwali Road, Bathinda (Pb.) 151001 India. Ph. No. 0164-2280715, 2282432 Fax- 0164-2282387, 2283927 Web Site:

More information

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy. Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that

More information

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS The S1 model is self-operated bellows sealed pressure excess valve. This series of

More information

NPS modular outdoor switch-disconnectors

NPS modular outdoor switch-disconnectors NPS modular outdoor switch-disconnectors 2 NPS Index Introduction... 4 Technology review... 5 NPS technology... 5 Product review... 9 Benefits... 9 Technical data... 10 Samples of pole installation...

More information

Inductive voltage transformers

Inductive voltage transformers Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They

More information

UNIWORLD series PNEUMATIC VALVES

UNIWORLD series PNEUMATIC VALVES UNIWORLD series PNEUMATIC VALVES 5100AD/E 07 2013 SINGLE SEAT TWO WAY ON-OFF VALVES PED 97/23/CE / ATEX 94/9/CE / MACHINERY DIRECTIVE 2006/42/CE TYPE 5100 AD Normally open air closes Face-to-face ASME

More information

Solenoid System FLANGE MOUNTING VERSION

Solenoid System FLANGE MOUNTING VERSION EVI 9S Solenoid System COIL The EVI 9S system by AMISCO includes a wide range of solenoid operators designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter of 8

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK 1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA 023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir

More information

TMF 600 ( cm³/rev.)

TMF 600 ( cm³/rev.) HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Outdoor vacuum breaker for railway applications - FSK II

Outdoor vacuum breaker for railway applications - FSK II Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL

More information

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals? White paper Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals? Darryl Moser, Business Development Manager, DEM Sales, ABB, Electrification Products Division

More information

Cast Iron Liquid Relief Valves

Cast Iron Liquid Relief Valves Cast Iron Liquid Relief Valves Features Bolted bonnet permits easy inspection and servicing without removal from system. Quality cast iron body and bonnet, insert and disc are available in either bronze

More information

Waveguide Directional Couplers. Cross Guide Couplers CC SERIES

Waveguide Directional Couplers. Cross Guide Couplers CC SERIES Directional Couplers Cross Guide Couplers CC SERIES Broad Wall Couplers Side Wall Couplers DC SERIES SC SERIES CROSS GUIDE COUPLERS (3PORT) Coupling Values: Nominal Coupling Values Accuracy V.S.W.R. 20

More information

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. MV-CONNEX, HV-CONNEX, IXOSIL Terminations, IXOSIL MSA Slip-on Joint Boxes CABLE SYSTEMS Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. Welcome to the CABLE SYSTEMS Centre of Competence.

More information

Precision Bourdon tube pressure gauges

Precision Bourdon tube pressure gauges Pressure gauges Precision pressure gauges High accuracy (class 0.6) Housing can be plumbed Serial number on dial Suitable as measuring equipment as per QA requirements DNV- and GOSSTANDART-certified A

More information

TECHNICAL CATALOGUE BALL VALVES: VIENNA

TECHNICAL CATALOGUE BALL VALVES: VIENNA TECHNICAL CATALOGUE BALL VALVES: STANDARD LOW BALL VALVES: Suitable for domestic water ServiceS, heating, airconditioning plants and compressed air SyStemS. BALL VALVES 116 BALL VALVE, STANDARD LOW size

More information

Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY

Condenser Bushings. OIL-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C AND IEEE C AN ALSTOM COMPANY PAO Condenser Bushings - kv BUSHINGS OI-TO-AIR - Oil-Impregnated Paper ANSI STANDARDS IEEE C.9.0-000 AND IEEE C.9.0-99 AN ASTOM COMPANY PAO bushings are capacitance-graded bushings with an oil-impregnated

More information

CATALOGUE TRACTION OUTDOOR DISCONNECTORS TYP QAD 3. 3 kv DC; 2500; 3000; 4000; 4500 A

CATALOGUE TRACTION OUTDOOR DISCONNECTORS TYP QAD 3. 3 kv DC; 2500; 3000; 4000; 4500 A CATALOGUE TRACTION OUTDOOR DISCONNECTORS Unsere Handelsvertretung in Deutschland TYP QAD 3 3 kv DC; 2500; 3000; 4000; 4500 A ISO 9001:2009 ISO 14001:2005 APPLICATION The outdoor traction disconnectors

More information

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure sensor for liquid and gaseous media QBE620-P... 1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal

More information

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009 THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009 1General Features 1.1Characteristics The butterfly valves, metal to metal sealing withy thin blade(or full tightening type, with o-ring blade), are

More information

3EQ Composite Housed Surge Arresters

3EQ Composite Housed Surge Arresters Power Transmission and Distribution 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters: Your

More information

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc. DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw

More information

BALL VALVES FILTERS TEST POINTS 8

BALL VALVES FILTERS TEST POINTS 8 BALL VALVES FILTERS TEST POINTS 8 8 PRODUCT CATALOGUE 357 HYDROSCAND BALL VALVES, FILTERS TEST POINTS TABLE OF CONTENTS BALL VALVES PAGE BALL VALVES The ball valves are mainly used as shut-down valves

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

CATALOGUE

CATALOGUE www.vemer.it Vemer offers to the Electrical Industry a wide range of products able to meet all the requirements of the modern installer. The digital programmable thermostats, time switches, measurement

More information

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

T YPE MZ DISTRIBUTION S TANDARD CUTOUT T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

TECHNICAL CATALOGUE BALL VALVES: VIENNA

TECHNICAL CATALOGUE BALL VALVES: VIENNA TECHNICAL CATALOGUE BALL VALVES: VIENNA TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds

More information

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

PC3.0/MNS R 690 V A Main low voltage distribution switchgear Technical catalogue PC3.0/MNS R 690 V - 6300 A Main low voltage distribution switchgear 1TTB900001D0201 PC3.0/MNS R main low voltage distribution switchgear Index General Introduction...2 Technical data...3

More information

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:

More information

TECHNICAL CATALOGUE BALL VALVES: PARIS

TECHNICAL CATALOGUE BALL VALVES: PARIS TECHNICAL CATALOGUE BALL VALVES: PARIS TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds

More information

TECHNICAL CATALOGUE BALL VALVES: VIENNA

TECHNICAL CATALOGUE BALL VALVES: VIENNA TECHNICAL CATALOGUE BALL VALVES: VIENNA TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds

More information

شركة كهرباء محافظة القدس المساهمة المحدودة

شركة كهرباء محافظة القدس المساهمة المحدودة Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories

More information

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...

More information

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258 PREFILTER MSKP59259238 4T Replacement for 1 x 8258 592 x 592 x 38 mm Media Synthetic fibers Frame Media area 3,20 m 2 Initial resistance 100 Pa @ 4250 m 3 /h Average arrestance 80% (As per ASHRAE 52.1)

More information

3EP6 porcelain surge arrester

3EP6 porcelain surge arrester www.siemens.com/energy/arrester 3EP6 porcelain surge arrester Safe, reliable, long-lasting, and stable Answers for energy. Compact design high mechanical stability Sealing system Spring Maximum values

More information

DC Tarction Power Supply Global product offering for DC traction power supply applications

DC Tarction Power Supply Global product offering for DC traction power supply applications DC RAILWAY INFRASTRUCTURE LINE CARD DC Tarction Power Supply Global product offering for DC traction power supply applications Since decades, ABB supplies worldwide traction power supply systems to deliver

More information

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS HV EARTHING AND SHORT CIRCUIT LANCE DEVICE For use on maintenance operation and reparation of system parts electrically insulated of interconnection station of hv with air insulation: on coloumn support

More information

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

STERI-TROL Clean Service 'S' series Two-port and Three-port Control Valves - DN15 (½") to DN100 (4")

STERI-TROL Clean Service 'S' series Two-port and Three-port Control Valves - DN15 (½) to DN100 (4) Page 1 of 17 Cert. No. LRQ 09608 ISO 9001 STERI-TROL Clean Service 'S' series Two-port and Three-port Control Valves - DN15 (½") to DN100 (4") TI-P183-02 CH Issue 3 Description STERI-TROL 'S' series are

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

Zinc Oxide Surge Arrester EXLIM R

Zinc Oxide Surge Arrester EXLIM R Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy

More information

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS COMPANY PROFILE Founded by the Giorgi family in 1967, CEDASPE has been manufacturing bushings and accessories for distribution and power

More information

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other

More information

FS40. Cheese Shredder

FS40. Cheese Shredder FS40 Cheese Shredder FS40 Class of Shredders Deville Technologies FS40 class of cheese shredders evolved to be the reference in its category of full block shredders. With special attention to hygiene,

More information

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R High Voltage Surge Arresters Buyer s Guide Section PEXLIM R Zinc Oxide Surge Arrester PEXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching

More information

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN

TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN TECHNICAL CATALOGUE GAS BALL VALVES: BERLIN TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds

More information

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv PASS M0S 252 kv Innovation In today s market, the HV substation is increasingly becoming a key element

More information