1 The BIG names in Cable for the BIG jobs in Cable

2 Control Treotham Automation is the exclusive distributor for one of the biggest names in the cable industry. Treotham now offers it s own exclusive brand of Treoflex range of cables. TREOFLEX VSD-EMC-UV-3 TREOFLEX XLPE-CY-JB TREOFLEX SDI - VSD TREOFLEX SDI 0 C TREOFLEX EARTH TREOFLEX TWIN FIGURE 8 Each office keeps a stock of the most popular items These are usually available for immediate dispatch. HELUKABEL is a leading international manufacturer and supplier of wires & cables, custom cables, cable accessories, data, network & bus technology and media technology. Helukabel is one of Europe s largest stockists of specialised cables. Helukabel s extensive warehouse stock, containing over 33,000 articles, enables Treotham to deliver your orders within extremely short delivery times. HELUKABEL produce for all markets and for every purpose, including; Flexible Control Cables Data Cables Cables for Drag Chains Servo, Feedback & Motor Cables Heat Resistant Cables All weather and Rubber Cables Trailing, Hoist and Crane Cables Robotic Cables Single Core Cables Cables to International Approvals Bus, DeviceNet & Network Technology Spiral Cables Ship Wiring & Marine Cables KABELWERK EUPEN AG is today a leading cable manufacturer in Europe and one of the few cable manufacturers that has all the manufacturing facilities on one site. This enables flexibility in all stages, from design, through manufacturing up to final product testing. EUPEN has solid experience with all major national and international standards as IEC, VDE, BS, NF, NBN, NEN & SEV. Power Crane Single Core High Temp Data Instrumentation Bus/Devicenet Robotic Solar High Flex

3 Contents Control Cables JZ 500 Control Cable PVC 300/500V 8-9 JZ-600 Control Cable PVC 0.6/kV 0- PURÖ-JZ Control Cable PUR 300/500V 2 OZ-BL Control Cable Intrinsically Safe 300/500V 3 EMC/VSD Cables TREOFLEX -EMC-UV-3 Screened VSD UV Stabilised 0.6/kV 4 TREOFLEX XLPE-CY-JB Screened VSD 0.6/kV 5 Y-CY-JB Screened VSD 450/750V 6 Y-CY-JZ Screened Control 300/500V 7 JZ-600 Y-CY Screened Control 0,6/kV 8-9 TREOFLEX SDI - VSD Screened SDI - VSD 0,6/kV 20 Power Cables H05 RR-F / H05 RN-F 500V Rubber-Sheathed Cable 2 H07 RN-F Rubber-Sheathed Cable kv POWERFLEX RV-K PVC Sheathed Cable kv 24 H05 BQ-F / H07 BQ-F* PUR Sheathed Cable 25 TAUCHFLEX Blue Rubber Sheathed Cable 26 NSGAFÖU 3.3kV SIngle Rubber 27 TREOFLEX SDI 0 C Single Double Insulated 0ºC 28 TREOFLEX EARTH Flexible Earth 0ºC 29 TREOFLEX WELDING FLEX Single Double Insulated 90ºC 30 TREOFLEX TWIN FIGURE 8 Figure 8 Double Insulated 3 TREOFLEX SINGLE CORE Single Core Flex V90HT 32 H05 V-K PVC & H07 V-K Single Cores VDE 33 Halogen Free JZ-500 HMH Control Cable 300/500V JZ-500 HMH-C Control Cable Screened 300/500V 36 JZ-600 HMH Control Cable 0.6/kV 37 JZ-600 HMH-C Control Cable Screened 0.6/kV 38 DATAFLAMM Data Cable Coloured Cores 39 DATAFLAMM-C Data Cable Screened Coloured Core 40 DATAFLAMM-C PAAR Data Cable Screened Pair 4 High Temperature SIHF Silicon Mulitcore 80 C 42 SIHF-C-SI Silicon Multicore Screened 80 C 43 SIF/SIFF Silicon Single Core 80 C 44 HELUTHERM Nickel Conductor 400ºC 45 6

4 Crane Cables PVC-FLAT H05 V V H6 / H07 V V H6 Flat 46 NEO-FLAT Rubber Sheathed Flat 47 PVC-FLAT-CY Screened PVC Flat 48 NEO-FLAT-CY Screened Rubber Sheathed 48 TRAGO / LIFT Lift And Hoist Control 49 NSHTÖU Drum Reeling 50 TROMMELFLEX PUR PUR Drum / Reeling 5 Data Cables TRONIC (LIYY) Flexible, Colour Coded 52 TRONIC-CY (LIYY) Screened Flexible Colour Coded 53 PAAR-TRONIC-CY Screened Paired Flexible 54 Bus/Devicenet PROFIBUS Indoor Fixed Profibus 55 CAN BUS Indoor Fixed Can Bus 56 DEVICENET Drop & Trunk Devicenet 57 Instrumentation Cable OVERALL SCREENED PAIRS 59 OVERALL SCREENED ARMOURED PAIRS 59 INDIVIDUAL & OVERALL SCREENED PAIRS 60 OVERALL SCREENED ARMOURED PAIRS 60 OVERALL SCREENED TRIADS 6 OVERALL SCREENED ARMOURED TRIADS 6 INDIVIDUAL & OVERALL SCREENED TRIADS 62 INDIVIDUAL & OVERALL SCREENED ARMOURED TRIADS 62 High SUPERTRONIC -PVC Un-sceened Cores PVC 63 SUPERTRONIC -C-PVC Sceened Cores PVC 64 SUPERTRONIC -PURÖ Un-sceened Cores PUR 65 SUPERTRONIC -C-PURÖ Sceened Cores PUR 66 SUPER-PAAR-TRONIC-C-PUR Sceened Pairs PUR 67 TOPSERV 0 / 20 TopServo / Feedback Cable 68 ROBOFLEX 200 / 200 Robot Control / Signal 69 Curly Cords PVC/PUR SPIRAL CABLE Solarflex SOLAR CABLE 70 Spiral Cords 7 PV-F Solar Cable TECHNICAL INFORMATION

5 JZ-500 control cable Technical data Control cables, special PVC Bare copper, fine wire conductors, Extensively oil resistant Requirements adapted to DIN VDE 0245, 028, 0293, 0295 according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Chemical Resistance - see table Technical Informations Temperature range Core insulation of special PVC Z 7225 PVC self-extinguishing and flame retardant flexing -5 C ) to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 300/500 V Black cores with continuous white numbering according to DIN VDE 0293 (also available with other core colours) according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Test voltage 4000 V Breakdown voltage min V Green-yellow earth core in the outer layer (3 cores and above) The materials used in manufacture are cadmium-free and contain no silicone and Insulation resistance min. 20 MOhm x km Cores stranded in layers with optimal lay-lenght free from substances harmful to the wetting properties of lacquers Minimum bending radius flexing 7,5x cable Ø fixed installation 4x cable Ø Outer sheath of special PVC, TM2 to DIN VDE 028 part and HD 2. colour grey (RAL 700) Note G = with green-yellow earth core; Radiation resistance up to 80x0 6 cj/kg (up to 80 Mrad) ) cold bending test, impact resistance test at low temperatures, elongation test at low temperatures. Tested according VDE 0473 Teil 8--4, EN with meter marking, change-over in 2009 x = without green-yellow earth core (OZ). These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines in machinery production, in air-conditioning and in steel production. The earth core is laid in the outer layer. Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x G x G x G x G G x G x G G x G G G G G G G G G G G Cop.eight x G x G x G x G G x G x G G G G G G G G G G G G G G G G

6 cross-sec. mm x G x G x G x G G x G G G x G x G G G G G G x G x G G x G G G G G G G x G x G x G x G G x G G G G G G G G G G G G G G G G cross-sec. mm x G x G x G x G x G G G G G G G G G G G x G G G G G G G G G G G G G G G G G G G G G G x G G G G G G / G / G / G / G / G / G / G kcmil G kcmil 9

7 JZ /kV, control cable Technical Data In accordance to DIN VDE 0262/2.95 and DIN VDE 028 part 3, with insulation wall thickness for kv Temperature Range flexing -5 C to + 80 C fixed installation - 40 C to + 80 C Nominal voltage U0/U 0,6/ kv Test voltage 4000 V Breakdown voltage min V Insulation resistance min. 20 MOhm x km Current carrying capacity in accordance to VDE 0298 part 4 Minimum bending radius flexing 7,5x cable ø fixed installation 4x cable ø Radiation resistance up to 80x06 cj/kg (up to 80 Mrad) cold bending test, impact resistance test at low temperatures, elongation test at low temperatures. Tested according VDE 0473 part 8--4, EN Notes Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few centremetres. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG x G x G x G x G G x G x G G x G G G G G G G G G G G G G G G x G Bare copper, fine wire conductors, as per DIN VDE 0295 cl.5, BS6360 cl.5 and IEC cl.5 Special PVC core insulation TI2, to DIN VDE 028 part Black cores with white figure imprints to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores stranded in layers with optimal lay-length Special PVC outer sheath TM2, to DIN VDE 028 part Colour black (RAL 9005) With meter marking, change-over in 20 Extensively oil resistant, oil/chemical resistance - see Technical Information PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers. UV- resistant Note G = with green-yellow earth core; x = without green-yellow earth core (OZ) Different dimensions are also available with red resp. blue cores. AWG sizes are approximate equivalent values. The actual cross-section is in mm². screened analogue type: Cop.eight x G x G x G x G x G x G G G G G G G G G G G G G G G G G G G

8 cross-sec. mm x G x G x G x G G x G G G x G x G G G x G G G G G x G x G G G x G G G G G G G G x G x G x G x G G G G G G G x G G G G G G G G G G G G G G G G G cross-sec. mm G x G x G x G x G G G G G G G G G G G x G G G G G G G G G G G G G G G G G G G G G G G G G G G G G / G / G / G / G / G / G / G kcmil G kcmil

9 PURö-JZ PUR control cable, oil resistant Technical data Special PUR cables adapted to DIN VDE 0245, 028 Temperature range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 300/500 V Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Oil resistant PVC core insulation TI2, adapted to DIN VDE 028 part, for better sliding abilities Resistant to UV-Radiation, Oxygen, Ozone and hydrolysis Microbes Self-extinguishing and flame retardant according to VDE , DIN EN Test voltage 4000 V Breakdown voltage min V Black cores with continuous white figure imprint to DIN VDE / IEC (equivalent DIN VDE 0472 part 804 test method B) Insulation resistance min. 20 MOhm x km Green-yellow earth core in the outer layer (3 cores and above) The materials used in manufacture are cadmium-free, contain no silicone and are Minimum bending radius flexing 7,5x cable Ø fixed installation 4x cable Ø Cores stranded in layers with optimal lay-length Special full-polyurethane outer jacket free from substances harmful to the wetting properties of lacquers Radiation resistance TMPU, to DIN VDE 0282 part 0, appendix A Note up to 00x0 6 cj/kg (up to 00 Mrad) Sheath colour grey (RAL 700) G = with green-yellow earth core; Jacket also available in other colours x = without green-yellow earth core (OZ). PURö-JZ is an extremely robust control cable with high abrasion and tear resistant properties, and a high-grade oil resistant PVC core insulation. Due to its high resistance to mineral oils and especially to coolant emulsions, it is especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor living. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x G G G G G G G G G G x G G G G G G G G G G x G G G G G G G G G G x G G G cross-sec. mm G G G G G G G x G G G G G G G G G G G G G G G G G G G G G G G G / G /0 2

10 OZ-BL intrinsic safety, control cable Technical data Control cable, special PVC with blue outer jacket for hazardous areas - hazard type -i- (=intrinsically safe) For intrinsically safe installation according to DIN EN and IEC section (VDE 065 part ) Temperature range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 300/500 V Test voltage 3000 V Breakdown voltage min V Insulation resistance min. 20 MOhm x km Inductance approx. 0,68 mh/km Minimum bending radius flexing 7,5x cable Ø fixed 4x cable Ø Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Core insulation of special PVC Z 7225 Black cores with white continuous figure imprint to DIN VDE 0293 without earth core Cores stranded in layers with optimal lay-length Special PVC outer sheath TM2, to DIN VDE 028 part and HD 2. Colour blue (RAL 505) Extensively oil resistant PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. These cables are not suitable for underground laying. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Also available OZ-BL-CY Outer jacket blue. Intrinsic safety. Flexible. EMC-preferred type OB-BL-PAAR-CY Outer jacket blue. Intrinsic safety. EMC-preferred type 3

11 Treoflex-UV UV stabilised VSD Cable 0.6/kV Technical Data Flexible cable with multi-stranded conductors, with a cross-linked XLPE polyethylene insulation, double stranding element screen, with UV resistant outer sheath made of a special type of PVC. Symmetric conductor construction (3+3PE, conductors arranged symmetrically every 20 ) Operating temperature: -40 C to 90 C Operating voltage: U/U = 0.6/ kv Test voltage: 2500V Insulation resistance: > 200 MOhm x km Capacitance: conductor/conductor = 70 to 250 nf/km conductor/screen = 0 to 40 nf/km Max. operating conductor temp: 90 C Min. bending radius: Ø<2 mm - 5 x Ø Ø=2+20 mm - 7,5 x Ø Ø>20 mm - 0 x Ø Cable Structure Conductors: flexible copper wire, class 5 as per PN-EN or PN-HD 383 S2 Conductor insulation: XLPE cross-linked polyethylene Conductor marking: black, brown, grey, yellow-green (3 + 3PE). Cores twisted together without fillers Screens: an electrostatic screen in the form of polyester tape covered with a layer of aluminium, and a second screen in the form of a tinned copper wire braid Sheath: special PVC, self-extinguishing and flame retardant (as per PN-N60332-), UV resistant Sheath colour: transparent/orange Low capacitance Self-extinguishing sheath UV resistant Fulfilment of electromagnetic compatibility (EMC) requirements* *Note: in order to ensure optimal screen earthing and the fulfilment of electromagnetic compatibility (EMC) requirements by the connection, we recommend using Treotham metal EMC glands (please refer to pages 35-38). Cables with a special construction, used to supply power to motors from frequency converters while maintaining full electromagnetic compatibility (EMC). The cross-linked XLPE polyethylene insulation improves current-carrying capacity, while at the same time maintaining low cable capacitance in comparison with cables with a PVC insulation. The cables are suitable for both fixed installation and movable connections in industrial equipment, process lines, and machines operating in dry and damp rooms. The symmetric construction of the cable (3+3PE) ensures the symmetry of supply voltages on the motor terminals. No of cores x cross section mm 2 c.a mm Current capacity amps un-enclosed touching Cop weight ca. Kg Gland part no. TA G TA G TA G TA E 3x6 + 3G TA E 3x0 + 3G TA E 3x6 + 3G TA E 3x25 + 3G TA E 3x35 + 3G TA E 3x50 + 3G TA E 3x70 + 3G TA E 3x95 + 3G TA E 3x20 + 3G TA E 3x50 + 3G TA E 3x85 + 3G TA E 3x G For suitable EMC glands, see pages

12 Treoflex XLPE-CY-JB XLPE VSD Cable 0.6/kV Technical Data: Flexible cable with multi-stranded conductors, with a cross linked XLPE polyethylene insulation, Tinned Cu Braid, Clear Sheath 0.6/kV Operating temperature: flexing -5 C to 90 C fixed installation -20 C to 90 C Operating voltage: Uo/U = 0.6/kV Test voltage: 4000V Min. bending radius 8 x cables diameter Cable Structure Conductors: flexible copper wire, class 5 Conductor insulation: XLPE Conductor marking: 2+E = blue, brown, green/yellow 3+E = red, white, blue, green/yellow 4+E = red, white, blue, black, green/ yellow Bedding: PVC compoud to as/nzs 3808 Screen: tinned copper wire braid Sheath: special PVC, self-extinguishing Self-extinguishing sheath Fulfilment of electromagnetic compatibility (EMC) requirements Flame retardant Rohs compliant AS/NZS & IEC Used to supply power to motors from frequency converters while maintaining full electromagnetic compatibility (EMC). The screening density assures disturbance free transmission of all signals and impulses. The cables are suitable for both fixed installation and moveable connections in industrial equipment, process lines, and machines operating in dry and damp rooms. cross-sec. mm 2 Current Capicity Gland No to suit cable 634AU 3 G AU 4 G AU 5 G AU 3 G AU 4 G AU 5 G AU 3 G AU 4 G AU 5 G AU 3 G AU 4 G AU 5 G AU 4 G AU 5 G AU 4 G AU 5 G AU 4 G AU 5 G For suitable EMC glands, see pages

13 Y-CY-JB PVC, VSD cable Technical data Special PVC control cables, adapted to E DIN VDE 0245, 028 part 3 Conductor resistance to DIN VDE 0295 Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Core insulation of special PVC Z 7225 Extensively oil resistant. Chemical Resistance - see Technical Information table PVC self-extinguishing and flame retardant Temperature range Core colour coded to JB/OB colour code according to VDE , DIN EN flexing -5 C to + 80 C fixed installation -40 C to + 80 C Green-yellow earth core in the outer layer (3 cores and above) / IEC (equivalent DIN VDE 0472 part 804 test method B) Nominal voltage U0/U 300/500 V to,5 mm² Cores stranded in layers with optimal lay-length The materials used in manufacture are cadmium-free, contain no silicone and are U0/U 450/750 V at 2,5 mm² Special PVC inner sheath free from substances harmful to the Test voltage 4000 V Tinned copper, braided screen, approx. 85% wetting properties of lacquers Breakdown voltage min V coverage Insulation resistance Transparent special PVC outer sheath Note min. 20 MOhm x km Coupling resistance max. 250 Ohm/km Minimum bending radius flexing 0x cable Ø fixed installation 5x cable Ø Radiation resistance up to 80x0 6 cj/kg (up to 80 Mrad) G = with green-yellow earth core; x = without green-yellow earth core (OB). By 5 cores with VDE-Reg. No. For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above application. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x G G G x G G G x G G G x G G G G G G G G G G G G G G G / G / G / G kcmil G kcmil 6

14 Y-CY-JZ Screened control cable Technical data Special PVC control cables, adapted to Bare copper, fine wire conductors, bunch E DIN VDE 0245, 028 part 3 stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 Conductor resistance and IEC cl. 5 to DIN VDE 0295 Core insulation of special PVC Z 7225 Temperature range Black cores with continuous white flexing -5 C to +80 C numbering to DIN VDE 0293 fixed installation -40 C to +80 C Green-yellow earth core in the outer layer Nominal voltage U0/U 300/500 V (3 cores and above) Test voltage 4000 V Cores stranded in layers with optimal Breakdown voltage min V lay-length Insulation resistance Special PVC inner sheath min. 20 MOhm x km Coupling resistance max. 250 Ohm/km Minimum bending radius flexing 0x cable Ø fixed installation 5x cable Ø Radiation resistance up to 80x0 6 cj/kg (up to 80 Mrad) Tinned copper, braided screen, approx. 85% coverage Transparent special PVC outer sheath Extensively oil resistant. PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Note G = with green-yellow earth core; x = without green-yellow earth core (OZ). For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The screening density assures disturbance free transmission of all signals and impulses. The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm 2 Cop. weight x G G G G G G G G G x G G G G G G G G G G x G G G G G G G G G cross-sec. mm x G G G G G G G G G x G G G G G G G G G G G G G G G G G G G G

15 JZ-600 Y-CY 0,6/kV, Cu screened control cable Technical Data In accordance to DIN VDE 0262/2.95 and DIN VDE 028 part 3 Temperature Range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 0,6/ kv Test voltage 4000 V Breakdown voltage min V Insulation resistance min. 20 MOhm x km Current carrying capacity according to VDE 0298 Minimum bending radius flexing 0x cable ø fixed installation 5x cable ø Radiation resistance up to 80x06 cj/kg (up to 80 Mrad cold bending test, impact resistance test at low temperatures, elongation test at low temperatures. Tested according VDE 0473 part 8--4, EN Bare copper, fine wire conductors, according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Special PVC core insulation TI2, to DIN VDE 028 part Black cores with sequential numbering imprinted in white, according to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores stranded in layers with optimal lay-length PVC -insulated inner sheath Braided screen of tinned Cu wires, coverage approx. 85% Special PVC outer sheath TM2, to DIN VDE 028 part Colour black (RAL 9005) With meter marking, change-over in 20 Extensively oil resistant, oil/chemical resistance - see Technical Information table PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers. UV resistant Note G = with green-yellow earth core; x = without green-yellow earth core (OZ). Further sizes are available upon request AWG sizes are approximate equivalent values. The actual cross-section is in mm². Unscreened analogue type: JZ-600 see pages 0- Notes Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burial or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few centmetres. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. Interference-free transmission of signals and pulses is assured by the high degree of screening. EMC = Electromagnetic compatibility To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG x G G G G G G G x G G G G G x G x G x Cop.eight 56 2 x G G G G G G G x G G G G G G G

16 JZ-600 Y-CY flexible, number coded, 0,6/kV, Cu screened meter marking, EMC-preferred type x G G G G G G G x G G G G G x G G G G x G G G G Cop.eight x G G G G G G G G G G G G G G G / G / G / G / G / G / G / G / G kcmil G kcmil 9

17 Treoflex SDI - VSD Single Core VSD Cable Technical Data Special screened single core for EMC applications Temperature range Flexing -30 C to + 90 C fixed installation -40 C to + 00 C Nominal Voltage U /U 600/000 V Test voltage 3000 V Insulation resistance min 200 MOhm x km Minimum bending radius fixed installation 5x cores Ø Cable Structure Tinned copper, fine wire conductors bunch stranded to DIN VDE 0295 class 5 Inner insulation of special thermoplastic polymer, natural coloured Screen of tinned cu-braid, coverage approx 85% Outer insulation of special polyolefine black (RAL 9005) Very good oil resistantce Halogen free Abrasion resistant Resistant to Hydrofluoric acid Hydrochluoric acid Diluted sulfuric acid Coolants Microbes UV-Radiation Weather The materials used in manufacture are cadmium-free and contain no silicone and are free from substances harmful to the wetting properties of lacquers The special single cores are used for permanent flexible applications in machines, machine tools, composting appliances and seweragetreatment plants, animal stalls and greenhouses. They are used for permanent flexible application for movable automated machinery parts and multi-shift operation, as well as in open air. These cables are installed for flexible use with free movements without tensile stress or forced movements and are suitable for application in drag chains. The selected tinned copper wire conductor and tinned copper wire braid permit the installation in aggressive environments as well as hydrogen sulfide, ammonia and sulfur dioxide. TREOFLEX - VSD These screened cables are particularly suitable for the interference-free transmission instrumentation and control engineering applications (electromagnetic compatibility). EMC = Electromagnetic compatibility. For application as a protective core, the ends are to be identified with green-yellow shrink-on tubes. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc). We recommend for our specially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. For further technical details see selection table for drag chain cables, see lead text. = The product is conformed with the EC Low-Voltage Directive 2006/95 TA x TA x TA x TA x TA x

18 H05 RR-F 500 V Rubber Sheathed Cable Technical data To DIN VDE 0282 part 4, HD 22.4 S4 IEC Bare copper conductors, fine stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC Resistant to Ozone H05 RR-F zusätzlich nach BS 6500 cl. 5 and HD 383 Oils and fats are allowed to come in touch Temperature range -30 C to +90 C Rubber core insulation EI4 to DIN VDE 0282 part Behaviour in fire according to VDE , DIN EN / Permissible operating temperature Cores laid up IEC (equivalent DIN VDE 0472 at conductor 90 C Cores colour coded to DIN VDE part 804 test method B) Nominal voltage U0/U 300/500 V and HD 86 Max. operating voltage Outer jacket black: Note three-phase and one-phase a.c. RR-F = Rubber, EM 3 to DIN VDE 0282 part G = with green-yellow earth core; U0/U 38/550 V RN-F = EM 2 to DIN VDE 0282 part x = without green-yellow earth core. for direct current U0/U 43/825 V Test voltage 2000 V Minimum bending radius approx. 7,5x cable Ø H05 RR-F These cables are suitable for connecting electrical appliances, for example vacuum cleaners, flat irons, soldering irons, kitchen appliances, toaster, stoves etc. They were also used for medium mechanical stress in households and offices. These cables are suitable for fixed installation in partition walls, furniture, decoration covering and in hollow spaces of prefabricated building parts. They are suitable for use in open air for short time, in industries (also permitted to tailor workshops and of that kind), in agriculture plants and for connecting commercial electrical tools. H05 RN-F These cables are suitable for connecting electrical equipment with low mechanical stress in dry, damp and wet places as well in open air, for example as connection cable for horticulture tools. These cables can be used in contact with fats and oils (for example deep fryer). They are also suitable for fixed installation, for example in furniture, decoration covering, partition walls and in hollow spaces of prefabricated building parts. The installation in hazardous areas is allowed. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. H05 RR-F cross-sec. mm x G G G x G G G x G G G x G G G G G G G H05 RN-F x G G G x G G G

19 H07 RN-F rubber-sheathed cable Technical data Rubber sheathed cable H07 RN-F to DIN VDE 0282 part 4, HD 22.4 S4, BS799 IEC Temperature range -30 C to +90 C Permissible operating temperature at conductor 90 C Nominal voltage U0/U 0.6/kV * The cable is designated 450/750V in accordance with VDE/IEC & meets or exceeds the AS5000- for the voltage rating of 0.6/kV, R-EP-90. Test voltage 2500 V Permanent tensile load max. 5 N/mm2 Minimum bending radius for fixed installation 4x cable Ø for guiding over roller 7,5x cable Ø during winding on drums 5-7x cable Ø Copper conductor fine wire stranded, bare to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC cl. 5 and HD 383 Rubber core insulation EI7 to DIN VDE 0282 part Insulation thickness to DIN VDE 0282 part 4 Core identification to DIN VDE and HD 86 Core colours 2 core: Blue, Brown 3 core: Blue, Brown, Green/Yellow 4 core: Brown, Black, Grey, Green/Yellow 5 core: Blue, Brown, Black, Grey, Green/Yellow 6 and more Black numbered Green/Yelow Cores stranded in layers with optimal lay-length Outer jacket of rubber black, rubber compound to DIN VDE 0282 part Sheath thickness to DIN VDE 0282 part 4 Resistant to Ozone Weather Submersible to 500 metres Test Test according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Ozone resistant of the insulation to DIN VDE 0472 part 805, test method A or part 805 A, test method C Oil resistant Test according to EN Note G = with green-yellow earth core; x = without green-yellow earth core. Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in agricultural plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws and homework tools as well as for transportable motors or machines at site. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 065 is allowed. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x x x x x x x x x x /0 370 x / x / x kcmil 3704 x kcmil 3705 x kcmil 3706 x kcmil 3707 x kcmil 3708 x kcmil x x x x x x x x G G G G G G G G G G G / G / G / G kcmil G kcmil 22

20 cross-sec. mm G G G G G G G G G G G / G / G / G kcmil G kcmil G kcmil G kcmil G G G G cross-sec. mm G G G G G G / G / G G G G G G G G G G G Current ratings for HO7 RN for current supply in industrial application Operating temperature at conductor 90ºC Ambient temperature 40ºC (Air) of cores -core 2-cores 3-cores 4-cores of loaded 2-cores loaded 3 cores loaded 2-cores loaded 3 cores loaded 3 cores loaded Cross section mm 2 Current ratings in Ampere (A) Note: For the method of installation: AS/NZS :998 - Refer to tables 4, 7, 0, 3 of AS/NZS Conversion factors for deviating ambient temperature Ambient tempurature at ºC

21 POWERFLEX RV-K XLPE/PVC Sheathed Technical Data Special PVC outer sheath Type DMV 8 according to HD 603 Temperature range -40 C to + 90 C Nominal voltage 0.6/kV Minimum bending radius 5 x cable diameter Cable Structure Flexible electrolytic annealed copper conductor class 5 according to IEC60228 Core insulation XLPE. type DIX3 according to HD603 Colour coded conductors Special PVC outer sheath Extensively oil resistant No flame propagation Resistant to Ozone Chemicals Oil Submersible to 200m Heavy duty special PVC sheath flexible cable suitable for use in dry, damp, wet areas as well as open air and submersible. The cross linked polyethylene insulation ( XLPE ) allows greater power transmission as well as a higher resistance to overloads. Its flexibility makes the installation process substantially easier and as a result is particularly suitable for use in difficult layouts. It can be buried or installed in conduits as well as used outdoor without requiring additional protection. The Powerflex RV-K can withstand total water immersion. No. No. of Cores x cross-sec Outer Diameter Current Rating 3700RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K x RV-K 2 x RV-K 2 x RV-K 2 x RV-K 2 x RV-K 2 x RV-K 2 x RV-K 3 x RV-K 3 x RV-K 3 x RV-K 3 x RV-K 3 x No. No. of Cores x cross-sec Outer Diameter Current Rating 37033RV-K 3 x RV-K 3 x RV-K 3 x RV-K 3 x RV-K 3 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 4 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x RV-K 5 x

22 H05 BQ-F / H07 BQ-F* PUR sheathed cable Technical data EPR/PUR-insulated power cable according to DIN VDE 0282 part 0 and HD 22.0 S Temperature range flexing -40 C to +80 C fixed installation -50 C to +90 C Permissible operating temperature at conductor 90 C Nominal voltage a.c., 50 Hz H05BQ-F: U0/U 300/500 V up to mm2 H07BQ-F: U0/U 450/750 V as of,5 mm2 Test voltage H05BQ-F: 2000 V up to mm2 H07BQ-F: 2500 V as of,5 mm2 Minimum bending radius flexing 5x cable Ø fixed installation 3x cable Ø Radiation resistance up to 00x0 6 cj/kg (up to 00 Mrad) Plain copper conductor, stranded according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and HD 383 cl. 5 Insulating jacket of rubber, compound EI6 according to DIN VDE 0282 part Core identification according to DIN VDE and HD308 S2 Green-yellow earth core in the outer layer Cores stranded in layers with optimal lay-length (inner protection sheath permissible) PUR-insulated outer jacket TMPU, to DIN VDE 0282 part 0, appendix A Colour orange (RAL 2003) Minimum imprinted designation BQ Abrasion resistant Notch resistant Resistant to tearing and cutting Good flexibility at low temperatures down to -40 C Resistant to Oils and fats Petrol Water and weathering effects Oxygene and ozone UV-radiation Hydrolysis Microbial attack The materials used in manufacture are cadmium-free and contain no silicone and are free from substances harmful to the wetting properties of lacquers Note G = with green-yellow earth core; x = without green-yellow earth core. These harmonized types H05BQ-F and H07BQ-F replace the VDE-standardised types. 7 G,5 mm2 and 2 G,5 mm2 are not contained in VDE, adapted to VDE, (H)07BQ. These cables can be used for medium mechanical loads in dry, damp or wet environments, e.g. for connecting agricultural and commercial equipment and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables are used for electrical tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building sites, docks and refrigeration plants. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG x G G G x G G G x G G G G G x G G G x G G G x G G G x G G G x G G G

23 Tauchflex-R blue rubber sheathed cable Technical data Special cables corresponding to Bare copper, fine wire conductors, bunch Good insulation properties when DIN VDE 0250 and 0282 part 80 Temperature range stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 submerged in water Minimal weight gain under water -40 C to +80 C (max. temperature for the Foil as separator The mechanical stability of the insulation outer surface) Permissible operating temperature EPR core insulation, compound type 3GI3 to DIN VDE 0207 part 20 materials remains constant even when submerged at conductor +90C Colour code according to DIN VDE 0293 Not suitable for drinking water. Nominal voltage U0/U 450/750 V Cores standed in layers with optimal Cables for use in drinking water with Operating voltage for alternating and lay-length BAM-certificate on request (BAM three-phase currents U0/U 43/825 V, for direct currents U0/U 69/238 V EPR outer sheath, blue, compound type 5GM3 adapted to DIN VDE 0207 part 2 Bundesanstalt für Materialprüfung/Federal Institute for Materials Testing). Current rating to DIN 5700 part 523/ Minimum bending radius Installation adaptability for machinery VDE 000 part 523 flexing material of protection class II Test voltage 5 min 2,5 kv up to 8 mm cond. Ø min. 3x cond. Ø As rotor-connection cable for motors up Max. permitted tensile stress per mm2 conductor 5 N above 8 mm to 2 mm cond. Ø min. 4x cond. Ø to 000 V with protected fixed installation in tubes. above 2 mm cond. Ø min. 5x cond. Ø fixed installation Note up to 2 mm cond. Ø min. 3x cond. Ø G = with green-yellow earth core; above 2 mm cond. Ø min. 4x cond. Ø x = without green-yellow earth core. Temperature limit in water: max. +40 C, max. +60 C with limited duration of life in air: flexible -50 C to +80 C stationary -30 C to +80 C AWG sizes are approximate equivalent values. The actual cross-section is in mm2. Please note: halogen-free types available on request. Tauchflex-R is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and has proven its worth for constant use in waste water or water for general use up to the depth of immersion of 500 m (50 bar) and temperatures of up to 70 C. Tauchflex-R can also be installed for use in dry, damp and humid areas as well as in the open air. Not suitable for installation in hazardous areas. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x x x x x x x x x x /0 370 x /0 37 x /0 372 x kcmil 373 x kcmil 374 x kcmil 375 x kcmil x x x x x x x x x x x cross-sec. mm x x x x x x / x / x / G G G G G G G G G G / G / G / G G G G G G G

24 NSGAFÖU 3.3kV Single Rubber Technical data Special rubber-insulated single core cables to DIN VDE 0250 part 602 Temperature range flexing -25 C to +90 C fixed installation -40 C to +90 C Permissible operating temperature at conductor 90 C Nominal voltage U0/U,8/3 kv Max. permissible operating voltage for three and one-phase alternating current operation U0/U 2,/3,6 kv, for direct current operation U0/U 2,7/5,4 kv Test voltage 6 kv Minimum bending radius 5x cable Ø Tinned copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5 and IEC cl. 5 EPR-insulation, compound type 3GI3 to DIN VDE 0207 part 20 Polychloroprene outer jacket oil resistant, and abrasion resistanct Colour black or red Oil resistant Test to DIN VDE 0473 part 8-2- Behaviour in fire Test according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting assemblies where because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under operating conditions which are in accordance with those specified for the intended application. Note Version in 6 kv available on request. icularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also suitable for laying in dry environments x x x x x x x x cross-sec. mm x x /0 385 x / x / x kcmil 3852 x kcmil 3855 x kcmil 3856 x kcmil 27

25 Treoflex SDI Flexible 0ºC 0.6/kV Low Smoke Halogen Free Technical Data Extra flexible special LSHF R-E-0 Temperature range -40ºC to + 0ºC Nominal voltage 0.6/kV Bending radius 6 x cable diameter Cable Structure Annealed bare copper conductors Class 6 fine stranding Insulation of special R-E-0 low smoke halogen free 0ºC, colour white Outer sheath of special R-HF-0 thermoset compound LSHF 0ºC, colour orange. Low Smoke Halogen Free (LSHF, LS0H, LSZH) UV Stabilised Flame Retardant Resistant to: oils, petrol, acids, sea water Submersible to 200 metres Relevant Standards AS/NZS25, AS/NZS3808, IEC60332-, AS/NZS5000. Flexible single core double insulated for use in switchboards, busbars, transformers, welding leads, battery charges. Size mm 2 Nominal Stranding Cable Diameter mm Cable KG/KM Conductor Ω/KM Voltage Drop@50Hz MV/A Current Rating Spaced Amps* Current Rating Touching Amps* TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / * Current ratings based on AS/NZS3008..:2009 Table 9 Columns 3 and 7. Note: Please complete the part number for these cables by adding the below suffix for the colour required as per the list: OE = Orange, following colours are available on request; RD = Red, BE = Blue, BK = Black, WE = White. Motor current table, Amperes Power kw hp Single Phase 240V Three Phase 45V Power kw hp Single Phase 240V Three Phase 45V

26 Treoflex Flexible Earth 0.6/kV Low Smoke Halogen Free 0ºC Technical Data Special soft cross linked X-HF-0 Temperature range -40ºC to + 0ºC Nominal voltage 0.6/kV Bending radius 6 x cable diameter Cable Structure Tinned copper conductors for sizes 0.75mm2 to 6mm2 Annealed bare copper conductors for size 0mm2 and over Class 6 fine stranding Insulation of special Soft X-HF-0 Low Smoke Halogen Free (LSHF, LS0H, LSZH) UV Stabilised Flame Retardant Relevant Standards AS/NZS25, AS/NZS3808, IEC60332-, IEC (A), IEC 6034, AS/NZS5000. Flexible single core earth cable for use in switchboards, mains and sub-mains, transformers and generators. Size mm 2 Nominal Stranding Thickness of Insulation mm Cable Diameter mm Approx Kg/Km Conductor 20º Ω/Km Voltage MV/A TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / Minimum size of copper earthing conductor Nominal area active mm² Cu Earth mm² Nominal area active mm² Cu Earth mm² A.W.G conversion to mm² A.W.G Dia mm mm² A.W.G Dia mm mm² 0000 (4/0) (3/0) (2/0)

27 Treoflex Welding Flex 90ºC 0.6/kV Technical Data Extra fine wire to ensure maximum flexibility Temperature range -30ºC to 90ºC static -20ºC to 90ºC flexing Nominal voltage 0.6/kV Bending radius 5 x cable diameter Cable Structure Annealed bare copper conductors Class 6 fine stranding Insulation of very flexible NBR 90ºC, colour white Outer sheath of special NBR Available colours: Orange, Red, Blue, Black, White UV Stabilised Flame Retardant Resistant to: oils, acids, sea water Relevant Standards AS/NZS25, IEC60332-, AS/NZS5000. Flexible single core double insulated for use in switchboards, busbars, transformers, welding leads and battery charges. Size mm2 Nominal Stranding Cable Diameter mm Cable KG/KM Conductor Ω/KM Three-Phase Voltage MV/A Current Rating Spaced Amps* Current Rating Touching Amps* TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / * Current ratings based on AS/NZS3008..:2009 Table 8 Columns 3 and 9. Note: Please complete the part number for these cables by adding the below suffix for the colour required as per the list: OE = Orange, RD = Red, BE = Blue following colours are available on request; BK = Black, WE = White. Nominal Area mm 2 Welding Current Rating (Amps) Maximum Duty Cycle percent to AS/NZS * Current ratings based on a conductor temperature of 90 C and in ambient air temperature of 40 C 30

28 Treoflex Figure 8 Twin 0.6/kV Technical Data Extra fine wire to ensure maximum flexibility Temperature range -30 C to + 75 C static -20 C to + 75 C flexing Nominal voltage 0.6/kV Bending radius 5 x cable diameter Cable Structure Annealed bare copper conductors Class 6 fine stranding Insulation of very flexible NBR 90ºC Outer sheath of special PVC Colour : Red and Blue (red and black on request) UV Stabilised Flame Retardant Relevant Standards AS/NZS25, IEC60332-, AS/NZS5000. For use as a battery/jumper cable or battery powered equipment like forklifts and also for Telecom companies for phone equipment. Size mm 2 Conductor Structure No. / Wire mm Thickness of Insulation mm Thickness of Sheath mm Overall Diameter mm Conductor Ω/Km Approx Kg/Km TA x.5 48/ x TA x / x TA x 4 27/ x TA x 6 90/ x TA x 0 38/ x TA x 6 504/ x TA x / x TA x 35 74/ x TA x / x TA x / x Current Rating Amps Duty Cycle Current Rating (A) Size 00% 85% 60% 30% 20% 0% 2 x x x x x x x x

29 Treoflex V90HT 0.6/kV Flexible Single Core Technical Data PVC single core to V90HT Temperature range -20 C to + 90 C Nominal voltage 0.6/kV Bending radius 3 x cable diameter Cable Structure Annealed tinned copper conductors to AS25 Class 5 and 6 fine stranding Insulation of special soft V90HT PVC Flame Retardant RoHS Relevant Standards AS/NZS25, AS/NZS3808, IEC60332-, AS/NZS5000. Flexible single core cable for use in switchboards, transformers and other equipment requiring fixed and flexible single cores. Size Nominal Stranding Thickness of Insulation mm Approx Diameter mm Cable KG/KM Conductor Ω/KM Current Rating amps Voltage Drop@50Hz MV/A TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / TA / Note: Please complete the part number for these cables by adding the below suffix for the colour required as per the list: BK = Black, RD = Red, WE = White, BE = Blue, BN = Brown, GY = Grey, VT = Violet, OE = Orange, PK = Pink, GW = Green/Yellow. Current Ratings: Table 6 Column AS/NZS : 998 For immediate sales or product enquiries NSW VIC QLD W.A NZ Phone: (02) Phone: (03) Telephone: (07) Phone: (08) Phone: (09) Fax: (02) Fax: (03) Fax: (07) Fax: (08) Fax: (09) info@treotham.com.au info@treotham.co.nz 32

30 H05 V-K PVC- Single Cores, fine wire stranded Technical data PVC single cores to DIN VDE H05 V-K/H05 V-U to DIN VDE 028 part 3, HD 2.3 S3 and IEC Temperature range flexing -5 C to +70 C fixed installation -30 C to +80 C Nominal voltage U0/U300/500 V Test voltage H05 V-K 2000 V Insulation resistance min. 0 MOhm x km Minimum bending radius 2,5x cable Ø Bare copper fine wire stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383 and IEC cl. 5 PVC core insulation, compound TI to DIN VDE 0028 part 3, HD 2.3 S3 and IEC PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Crosssection mm 2 Min-Max mm Cop weight kg / km black gn-ye blue brown red white grey vio ye pink green trans dk-bu og o.col. 2-col. u-blue No mm No mm No mm H07 V-K / (H)07 V-K PVC- Single Cores, fine wire stranded Technical data PVC single cores to DIN VDE 028 part 3, HD 2.3 S3 and IEC Temperature range flexing -5 C to +70 C fixed installation -30 C to +80 C Nominal voltage U0/U 450/750 V Test voltage 2500 V Insulation resistance min. 0 MOhm x km Minimum bending radius 2,5 to 5x cable Ø Crosssection mm2 Min-Max mm Cop weight kg / km Bare copper fine wire stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383 and IEC cl. 5 PVC core insulation, compound TI to DIN VDE 028 part 3, HD 2.3 S3 and IEC Core colours see below Core Identification with nominal voltage U0/U 450/750 V PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free contain no silicone and are free from substances harmful to the wetting properties of lacquers black gn-ye blue brown red white grey vio ye pink green trans dk-bu og 2-col. u.blue No mm No mm No mm No mm H05 V-K PVC-Single Cores, fine wire stranded 33

31 JZ-500 HMH flexible control cable. halogen free. extremely fire resistant. oil resistant Technical data Halogen-free flexible control cable, adapted to E DIN VDE 028 part 4 and DIN VDE 028 part 3 Temperature range flexing -5 C to +70 C fixed installation -40 C to +70 C Nominal voltage U0/U 300/500 V Test voltage 2000 V Minimum bending radius flexing approx. 2,5x cable Ø fixed installation approx. 4x cable Ø Radiation resistance up to 00x0 6 cj/kg (up to 00 Mrad) Bare copper, fine wire conductors, to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Core insulation of halogen-free compound TI6, to E DIN VDE 028 part 4 Black cores with white continuous numbering to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores stranded in layer with optimal lay-length Halogen-free sheath compound TM7, to E DIN VDE 028 part 4 Outer jacket colour grey (RAL 700) LS0H = Low Smoke Zero Halogen-free. Halogen-free, fiame retrdant cables are used as measureing and contro cable in machine tools, conveyor belts, production lines as well as in plant installations, in air conditioning and steel production works. For fixed installation or flexible application, directed without forcing by casual, not constantly recurring free movements and without tensile stress, formedium mechanical strain. This cable is suitable for the application in dry, damp and wet environments and also for laying on, in and under plaster as well as in concrete and masonary excluding in direct laying in shaked or stamped concrete, not suitable for imbedding in solidified or compressed concrete. The product is conformed with the EC Low-Voltage Directive 2006/95/EG. For the critical applications we advise for consultation The materials used in manufacture are cadmium-free contain no silicone and are free from substances harmful to the wetting properties of lacquers Tests Flame test to VDE 0482 part 266-2, BS 4066 part 3/ DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method C) Self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Corrosiveness of combustion gases according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 83) Halogen-free according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 85) Smoke density according to VDE 0482 part / IEC / DIN EN / BS 7622 part +2 (equivalent DIN VDE 0472 part 86) Note G = with green-yellow earth core; x = without green-yellow earth core (OZ). Please note the clean room qualification when ordering. cross-sec. mm x G x G x G x G G G G G G G G G G G G G G G G cross-sec. mm x G x G x G x G x G G G G G G G G G G G G G G

32 cross-sec. mm x G x G x G G G G G G G G G G G G G G G G x G x G G G G G G G G G G G G G G G G G G G G G G G G G G G cross-sec. mm x G G G G G G G G G x G G G G x G G G G x G G G G G G G G G G G G G G / G / G / G / G /0 35

33 JZ-500 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil resistant), Cu-screened, EMC-preferred type Technical Data Halogen-free core, flexible control cable, adapted to DIN VDE 028 part 4 and DIN VDE 028 part 3 Temperature range flexing -5 C to +70 C fixed installation -40 C to +70 C Nominal voltage U0/U 300/500V Test Voltage 2000V Minimum Bending Radius flexing approx. 2.5 x cable ø fixed installation approx. 4x cable ø Radiation resistance up to 00 x 06 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductor to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Core insulation of halogen-free compound TI6, to E DIN VDE 028 part 4 Black cores with continuous white numbering according to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores layed up in layers with optimal lay length Separating layer Screen braid of tinned copper wires, coverage approx 85% Halogen-free sheath compound TM7 to E DIN VDE 028 part 4 Jacket colour Grey (RAL 700) With meter marking, change over in 20 LSOH = Low Smoke Zero Halogen-Free Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments for installation above, on, in and beneath plaster as well as in masonry and concrete walls. It cannot be used for direct embedding in vibrated, compact ed or tamped concrete and it is not suitable for embedding in solidified or compressed concrete. An interference-free transmission of signals and pulse in assured by the high degree of screening. EMC = Electromagnetic compatibility To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. For critical applications recommend you request a consultation. The materials used in manufacture are cadmium free, contain no silicone and are free from substances harmful to the wetting properties of lacquers. Tests Flame test acc. to VDE , BS /DIN EN /EIC (equivalent DIN VDE Test Method C) Self-extinguishing and flame retardant according to VDE , DIN EN /IEC (equivalent DIN VDE 0472 part 804 test method B) Corrosiveness of combustion gases acc. to VDE /DIN EN /IEC (equivalent DIN VDE 0472 part 83 Halogen-free according to VDE 0482, 267/DIN EN / IEC (equivalent DIN VDE 0472 part 85) Smoke density according to VDE 0482 part / IEC / DIN EN / BS 7622 part +2 equivalent DIN VDE 0472 part 86) Note G = without green-yellow earth core; X = without green-yellow earth core (OZ). Clean room qualification tested with analog type. Please note clean room qualified when ordering. Unscreened analogue type: JZ-600 HMH-C cross-sec. mm x G x G x G G G G G x G x G x G x G x G G G x G x G x G G G G G cross-sec. mm x G x G G G G G G x G G G G G x G G G G G G G G G x G G G G

34 JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil resistant), 0,6/kV, meter marking Technical Data Halogen-free, flexible control cable, adapted to DIN VDE 028 part 4 and DIN VDE 028 part 3 Temperature range flexing -5 C to +70 C fixed -40 C to +70 C Nominal voltage U0/U 0,6/ kv Bending radius 6 x cable diameter Test Voltage 4000V Minimum Bending Radius for permanent bending approx 5x cable diameter Radiation resistance up to 00 x 06 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductor to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and/or IEC cl. 5 Halogen-free polymer core insulation, TI6 acc. to E DIN VDE Black cores with continuous white numbering according to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores stranded in layers with optimal lay length Halogen-free polymer sheath, TM7 acc. to E DIN VDE Sheath colour black (RAL 9005) with meter marking, change over in 20 LSOH = Low Smoke Zero Halogen-Free Halogen-free, flame retardant cables are used as measuring and control cables in machine tools, conveyor belts, production lines as well as in plant installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in dry, damp and wet environments as well as outdoors (fixed installation) and for laying on, in and under plaster, concrete and masonary excluding in-direct laying vibration, compacted or compressed concrete. EMC = Electromagnetic compatibility = The product is conformed with the EC Low Voltage Directive 2006/95/EG. For critical applications we recommend you request a consultation. The materials used in manufacture are cadmium free, contain no silicone and are free from substances harmful to the wetting properties of lacquers. Tests Flame test acc. to VDE BS /DIN EN /EIC (as per DIN VDE Test Method C) Self-extinguishing and flame retardant according to VDE , DIN EN /IEC (equivalent DIN VDE 0472 part 804 test method B) Corrosiveness of corrosive gases acc. to VDE /DIN EN /IEC (as per DIN VDE ) Halogen-free acc. to VDE 0482, 267/ DIN EN / IEC (as per DIN EN 0472, 85) Smoke density according to VDE 0482 part / BS 7622 part +2 (equivalent DIN VDE 0472 part 86) Note G = without green-yellow earth core; X = without green-yellow earth core (OZ). Screened analogue type JZ-600 HMH-C cross-sec. mm x G x G x G G G G G x G x G x G G G G G x G x G x G G G G G x G x G x cross-sec. mm G G G G G x G x G x G x G G G G G G G G G G G G G G G G G G G G G G G G / G / G /0 37

35 JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil resistant), 0,6/kV, screened, EMCpreferred type, meter marking Technical Data Halogen-free, flexible control cable, adapted to DIN VDE 028 part 4 and DIN VDE 028 part 3 Temperature range flexing -5 C to +70 C fixed -40 C to +70 C Nominal voltage U0/U 0,6/ kv Bending radius 6 x cable diameter Test Voltage 4000V Minimum Bending Radius for permanent bending approx 5x cable ø Coupling resistance max. 250 Ohm/km Radiation resistance up to 00 x 06 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductor to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and/or IEC cl. 5 Halogen-free polymer core insulation, TI6 acc. to E DIN VDE Black cores with continuous white numbering according to DIN VDE 0293 Green-yellow earth core in the outer layer (3 cores and above) Cores stranded in layers with optimal lay length Inner sheath Tinned copper braided screening, coverage approx 85% Free polymer sheath, TM7 acc. to E DIN VDE Sheath colour black (RAL 9005) With meter marking, change-over in 20 The materials used in manufacture are cadmium free, contain no silicone and are free from substances harmful to the wetting properties of lacquers For critical applications we recommend you request a consultation Tests Flame test acc. to VDE BS / DIN EN EN /IEC (as per DIN VDE Test Method C Self-extinguishing and flame-resistant acc.to DIN VDE / EN / IEC (as per DIN VDE Test Method B) Corrosiveness of corrosive gases acc. to VDE 0482, 267/ DIN EN / IEC (as per DIN VDE 0472, 83) Halogen-free acc. to VDE 0482, 267/DIN EN / IEC (as per DIN DIN VDE 0472, 85) Smoke density according to VDE 0482 part / BS 7622 part +2 / IEC / DIN EN / BS 7622 part +2 (equivalent DIN VDE 0472 part 86) Note Unscreened analogue type JZ-600 HMH s Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant installations, in heating and air-conditioning systems and steel production works. Suitable for fixed installation or flexible application, directed without forcing by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. It is also for the application in dry, damp as well as wet environments and outdoors (fixed installation) and for laying on, in and under plaster. Also in concrete and masonry excluding in-direct laying in vibration, compacted or compressed concrete. The dense screening assures interference-free transmission of all signals and impulses. EMC = Electromagnetic compatibility = The product is conformed with the EC Low Voltage Directive 2006/95/EG. cross-sec. mm G G G G G G G G G G G G G G G G G G G G G G G G G G G G cross-sec. mm G G G G G G G G G G G G G G G G G G G G G G G G G G G / G / G / G /0 38

36 DATAFLAMM halogen-free, meter marking Technical Data Special data cable Temperature range flexing +5 C to +70 C fixed installation -40 C to +70 C Nominal voltage 0.4 mm2 = 350 V >0.4 mm2 = 500 V Test Voltage 0.4 mm2 = 800 V >0.4 mm2 = 200 V Insulation resistance min. 2 G Ohm x km Capacitance core/core <70 nf/km Minimum Bending Radius flexing approx. 2.5 x cable ø fixed installation approx. 4x cable ø Radiation resistance up to 00 x 06 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductors to DIN VDE 082 conductor make-up for 0,34 mm² - 7x0,25 mm PE-insulation, compound type 2YJ topound TI6, to E DIN VDE 028 part 4 DIN VDE 0207 part 2 Cores colour coded to DIN 4700 Cores twisted up in layers with optimal lay length Halogen-free outer sheath, DIN VDE 0207 part 24, compound type HM2 Sheath colour Grey (RAL 7005) With meter marking, change over in 20 Halogen-free according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 85) Corrosiveness of combustion gases according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 83) Halogen-free sheath compound, self-extinguishing and flame retardant according to DIN VDE 0482 part / EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Note Screened analogue type: DATAFLAM-C DATAFLAMM halogen-free data cables are used as connecting cables for signal, measuring, control, call-announcing, two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments as well as in masonry and concrete. PE-insulated-cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable capacitance value. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x cross-sec. mm x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

37 DATAFLAMM-C EMC-preferred type, halogen-free, screened, meter marking Technical Data Special data cable Temperature range Temperature Range flexing +5 C to +70 C fixed installation -40 C to +70 C Opreating top level voltage (not for purposes of high current and power installation) 0,4 mm² = 350 V >0,4 mm² = 500 V Test Voltage 0,4 mm² = 800 V >0,4 mm² = 200 V Insulation resistance min. 2 GOhm x km Capacitance core/core <70 nf/km Minimum Bending Radius approx. 7,5x cable ø Coupling resistance max. 250 Ohm/km Radiation resistance up to 00 x 06 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductors to DIN VDE 082, conductor make-up for 0,34 mm² - 7x0,25 mm PE-insulation, compound type 2YJ to DIN VDE 0207 part 2 Cores colour coded to DIN 4700 Cores twisted in layers with optimal lay-length Cores stranded in layers with optimal lay length Core wrapping with polyester (PETP) foil Tinned copper screened braiding, approx. 85% coverage Halogen-free outer sheath, to DIN VDE 0207 part 24, compound type HM2 Sheath colour grey (RAL 7005) With meter marking, change-over in 20 Halogen-free according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 85) Corrosiveness of combustion gases according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 83) Halogen-free sheath compound, self-extinguishing and flame retardant according to VDE 0482 part / to DIN VDE / DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) PE-insulated cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable capacitance values The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases Note Unscreened analogue type DATAFLAMM Dataflamm-C cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments as well as in masonry and concrete. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. With screened braiding offers interference-free signal transfer. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x cross-sec. mm x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

38 DATAFLAMM-C PAAR EMC-preferred type, halogen-free, screened, meter marking Technical Data Special data cable Temperature Range flexing +5 C to +70 C fixed installation -40 C to +70 C Opreating top level voltage (not for purposes of high current and power installation) 0,4 mm² = 350 V >0,4 mm² = 500 V Test Voltage 0,4 mm² = 800 V >0,4 mm² = 200 V Insulation resistance min. 2 GOhm x km Capacitance core/core <70 nf/km Minimum Bending Radius approx. 7,5x cable ø Coupling resistance max. 250 Ohm/km Radiation resistance up to 00 x 0 6 cj/kg (upto 00 Mrad) Cable Structure Bare copper, fine wire conductors to DIN VDE 082, conductor make-up for 0,34 mm² - 7x0,25 mm PE-insulation, compound type 2YJ to DIN VDE 0207 part 2 Cores colour coded to DIN 4700 Cores twisted in layers Core wrapping with polyester (PETP) foil Tinned copper screened braiding, approx. 85% coverage Halogen-free outer sheath, to DIN VDE 0207 part 24, compound type HM2 Sheath colour grey (RAL 7005) With meter marking, change-over in 20 Halogen-free according to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 85) Corrosiveness of combustion gases according to VDE 0482 part 267/DIN EN / IEC (equivalent DIN VDE 0472 part 83) Halogen-free sheath compound, self-extinguishing and flame retardant Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². Dataflamm-C PARR cables are used as connecting cables for signal, measuring, control, call-announcing, two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments as well as in masonry and concrete. PE-insulated cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable capacitance values. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. With screened braiding offers interference-free signal transfer. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases. EMC = Electromagnetic compatibility To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. cross-sec. mm x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x cross-sec. mm x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x

39 SiHF silicon mulitcore cable, flexible, halogen-free Technical data Special silicone multicore cable with higher heat-resistance range adapted to DIN VDE 0250 part and part 86 Temperature range -60 C to +80 C (up to +220 C for short time) Temperature limit at the conductor in operation +80 C Nominal voltage U0/U 300/500 V Test voltage 2000 V Breakdown voltage min V Insulation resistance min. 200 MOhm x km Power rating at ambient temperature up to +45 C to DIN VDE 000 for higher temperatures valid: 50 C - load value 00% 55 C - load value 9% 60 C - load value 82% 65 C - load value 7% 70 C - load value 58% 75 C - load value 4% Minimum bending radius flexing 7,5x cable Ø fixed installation 4x cable Ø Tinned fine wire copper conductors to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Silicone core insulation Core identification to DIN VDE colour coded or black cores with continuous white numbers For 2-cores brown, blue Cores stranded in layers with optimal lay-length Green-yellow earth-core (3 cores and above) Outer jacket of silicone Jacket colour preferably redbrown Advantages Hardly changes of dielectric strength and the insulation resistance also at high temperatures, high ignition or flash point, in case of fire, forms an insulating layer of SiO2 Resistant to High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV Halogen-free According to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 83) Behaviour in fire No flame propagation test according to DIN VDE 0482 part / EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for permanent temperatures up to +80 C and for short time operation up to +220 C. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60 C. Silicone cables are halogen-free and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Cop. weight x G G G G G G G G x G G x G G G G G G x G G G G G G G G x G G G G Cop. weight G G G x G G G G G G G G x G G G G x G G G G G G G G G G

40 SiHF-C-Si silicon multicore cable, halogen-free, Cu-screened EMC-preferred type Technical data Special silicone-insulated cable with higher heat-resistance adapted to DIN VDE 0250 part and part 86 Temperature range -60 C to +80 C (+220 C for short time) Temperature limit at the conductor in operation +80 C Nominal voltage U0/U 300/500 V Test voltage 2000 V Breakdown voltage min V Insulation resistance min. 200 MOhm x km Power rating at ambient temperatures up to +45 C according to DIN VDE C - load value 00% 55 C - load value 9% 60 C - load value 82% 65 C - load value 7% 70 C - load value 58% 75 C - load value 4% Minimum bending radius flexing 0x cable Ø fixed installation 5x cable Ø Coupling resistance max. 250 Ohm/km Radiation resistance up to 20x0 6 cj/kg (up to 20 Mrad) Tinned copper conductor fine wire according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 Core insulation of silicone Core identification according to DIN VDE , single colour, or black cores with sequential numbering imprinted in white, for 2 cores brown, blue Cores stranded in layers with optimal lay length Green-yellow earth core ( 3 cores) Inner sheath of silicone Braid of tinned Cu wires, coverage approx. 85% Silicone-rubber-insulated common outer jacket Jacket preferentially redbrown colour With meter marking, change-over in 2009 Resistant to High molecular oils, fats from vegetables and animals, alcohols, plasticisers and clophenes, diluter acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV Halogen-free According to VDE 0482 part 267/DIN EN / IEC (equivalent DIN VDE 0472 part 83) Burning behaviour No propagation of fire testing according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Note G = with green-yellow earth core; x = without green-yellow earth core. Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. These cables are heat-resistant for continuous use at temperatures up to +80 C as well as for short periods of time at +220 C. Silicone-rubber-insulated cables can also be used at low temperatures down to -60 C because of the excellent weathering resistance of the material. These cables are halogen-free. Silicone-rubber-insulated cables have demonstrated proven applications in projector and high-power lighting fixtures as well as all types of heating equipment. EMC = Electromagnetic compatibillity = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Cop. weight x G G G G G G G G G x G G G G G G G G G x G G G G G G G G G Cop. weight x G G G G G G G G G x G G G G G G G G G G G

41 SiF/SiFF silicon single cores, halogen-free Technical data Special-silicon single core with higher heat-resistance range adapted to DIN VDE 0250 Teil and part 502 Temperatue range -60 C to +80 C (up to +220 C for short time) Temperature limit at the conductor in operation +80 C Nominal voltage U0/U 300/500 V Test voltage 2000 V Breakdown voltage min V Minimum bending radius 5x cable Ø Radiation resistance up to 20 x 0 6 cj/kg (up to 20 Mrad) Type SiF Tinned copper conductors 0,5 mm² to DIN VDE 0295 Kl. 5, BS 6360 cl. 5 and IEC cl. 5 for 0,25 mm² = 4x0,5 mm Silicone core insulation Type SiFF as SiFF but with high flexible copper strands Strand make-up 0,25 to,0 mm² - cl. 6 col. 7 (single wire Ø 0,05 mm),5 to 0 mm² - cl. 6 col. 6 (single wire Ø 0,07 mm) Special cables for use in high and low temperature areas. They are used mainly in the steel producing industries, in aviation industries as well as in ship building, cement, glass and ceramic factories. As these cables are halogen-free, they are especially suited for use in power stations. SiF = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. SiFF Advantages High ignition or flash point Resistant to High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen Halogen-free According to VDE 0482 part 267/ DIN EN / IEC (equivalent DIN VDE 0472 part 83) Behaviour in fire No flame propagation test according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90 C. Note Please complete the part number for these cables by adding the suffix for the colour required as per the list: 00 = green, 0 = black, 02 = red, 03 = blue, 04 = brown, 05 = white, 06 = grey, 07 = violet, 08 = yellow, 09 = orange, 0 = transparent, = pink, 2 = beige, 3 = twin colour 232xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx SiF (Wire colour Black) / / / kcmil kcmil 44

42 HELUTHERM 400 Insulation Insulation class Cclass C Technical data Special core insulation Mono or multi coloured Temperature range -60 C to +400 C operating temperature (up to +450 C for short time) Nominal voltage 500 V Test voltage 2000 V Minimum bending radius approx. 8x cable Ø Radiation resistance up to x0 0 cj/kg (up to x0 4 Mrad) Stranded nickel conductor Overlapping with special heat-resistant impregnation These cables have very good electronic, chemical and radiation resistant properties Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². Also available with additional Kapton film at extra cost. The wide temperature range offered by this cable type makes it especially suited for use in the aviation and aerospace industries, for atomic power stations and in the steel making and chemical industries. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Cross-section mm 2 Conductor Construction black gn-ye blue brown red white grey vio ye Beige Pink og 2-col. trans No x No x No x No x No x No x No x No x No x No x No x No x No x No x No x No x No x No x

43 PVC-flat (H05 VVH6-F/H07 VVH6-F) 300/500V and 450/750V Technical data Special PVC-flat cable, Bare copper, stranded to DIN VDE 0295 cl. 5, H05 VVH6-F to EN 5024 BS 6360 cl. 5 and IEC cl. 5 H07 VVH6-F to HD 359 S2 Special PVC core insulation TI2 to (25 mm 2 and above in adapted) DIN VDE 028 part Temperature range Cores laying parallel flexing -5 C to +70 C Core identification up to 5 cores to colour fixed installation -40 C to +80 C code DIN VDE 0293 Nominal voltage H05 VVH6-F = up to mm² U0/U 300/500V H07 VVH6-F =,5 mm² U0/U 450/750 V Test voltage H05 VVH6-F = up to mm² 2000 V H07 VVH6-F =,5 mm² 2500 V Minimum bending radius 0x cable thickness Radiation resistance up to 80x06 cj/kg (up to 80 Mrad) 7 cores and above with number printing Green-yellow earth core Special PVC outer jacket TM2 to DIN VDE 028 part Colour black (RAL 9005) Extensively oil resistant Chemical Resistance - see Technical Information table Extremely small bending radius High flexibility Minimum waste of space Packeting possibility PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Note Art.No (6x4). G = with green-yellow earth core PVC type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. Installation notes: See NEO flat at page 47. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Outer dimension G x G x G x G x G x G x G x G x G x G x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G 4.5 x G x G x G x G x G x G x G x G x Outer dimension G x G x G x G x G x G x G 2.5 (6x4) 5.0 x G x G x G x G x G x G x G x G x G 6.2 x G x G x G x G x G x G x /0 46

44 NEO-flat NGFLGOU Technical data Special Neoprene-flat cable to DIN VDE 0250 Bare copper, stranded to DIN VDE 0295, Special rubber outer sheath, cold-resistant part 809 BS 6360 cl. 5 and IEC 60228, fine or extra Extensively oil resistant Temperature range fine wire stranded according to different Chemical Resistance - see Technical flexing -25 C to +60 C cross-sections Information table fixed installation -40 C to +80 C to 25 mm² - class 6, col. 4 Extremely small bending radius Nominal voltage U0/U 300/500 V 35 to 95 mm² - class 5 High flexibility Test voltage 3000 V Special rubber core insulation GI, to Minimum waste of space Minimum bending radius DIN VDE 0207 part 20 Packeting possibility 0x cable thickness Core identification up to 5 cores, colour Test according to VDE , DIN Radiation resistance code to DIN VDE 0293 EN / IEC (equivalent up to 50x0 6 cj/kg (up to 50 Mrad) 7 cores and above with number printing DIN VDE 0472 part 804 test method B) Cores laying parallel.no and 2803 cable structure Note 6x4 G = with green-yellow earth core; Green-yellow earth core x = without green-yellow earth core (OZ). Special rubber outer sheath 5GM2, to AWG sizes are approximate equivalent DIN VDE 0207 part 2 values. The actual cross-section is in mm². Colour black Neoprene type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are also available for export with UL-approval. Installation notes Cable reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this purpose, the corresponding fitting instructions should be followed. Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface of two cable trollys must be wider than the double thickness of a cable-packet. During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be built successively so that the biggest cross-section is laying on the top. Further, be careful of a symmetrical load distribution. In case of multicore flat cables with small cross-section, smaller than 2,5 mm², it is very critical due to its low tensile stress. In such case, you should add 0% reserve wire for calculation. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Outer dimension G x G x G x G x G x G x G.5 (6x4) 3.0 x G x G x G x G x G x G 2.5 (6x4) 5.5 x G x G x G x G x G x G x Outer dimension G x G x G 6.6 x G x G x G x G x G x G x G x G x G x / G x / G x /0 47

45 PVC-Flat-CY screened, EMC-preferred type Technical data Special PVC-flat cable, screened, adapted to DIN VDE 0283 part 2 Temperature range flexing -5 C to +70 C fixed installation -40 C to +80 C Nominal voltage U0/U 300/500 V Test voltage 3000 V Breakdown voltage min V Minimum bending radius 5x cable thickness Bare copper, fine wire conductors according to DIN VDE 0295 and IEC cl. 5, BS 6360 cl. 5 Special PVC insulation Core identification see below Cores screened individually or in bunches Cores laying parallel Copper screened braiding, approx. 85% coverage Special PVC outer jacket black (RAL 9005) Extensively oil resistant Extremely small bending radius High flexibility Minimum waste of space The high degree of screening density assures disturbance-free transmission of all signals and impulses PVC self-extinguishing and flameretardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) cross-sec. mm 2 Core marking Outer dimension mm t G 0.5 Colour coded. with earth core 2.0 x x 4 x 0.5 Colour coded 37.4 x x 7 x 0.5 Cont. white numbering 68.6 x G 0.75 Colour coded. with earth core 5.00 x x 4 x Colour coded 33.5 x G.5 Colour coded. with earth core 8.70 x G.5 Cont. white numbering. with earth core x G.5 Cont. white numbering. with earth core 52.0 x G 2.5 Colour coded. with earth core 2.00 x G 2.5 Cont. white numbering. with earth core 37.4 x G 4 Colour coded. with earth core x G 6 Colour coded. with earth core 30.0 x G 0 Colour coded. with earth core x G 6 Colour coded. with earth core 4.30 x G 25 Colour coded. with earth core x NEO-Flat-CY (MCHÖU) screened, EMC-preferred type Technical data Special-Neoprene-flat cable, screened, adapted to DIN VDE 0250 part 809 Temperature range flexing -25 C to +60 C fixed installation -40 C to +80 C Nominal voltage U0/U 300/500 V Test voltage 3000 V Minimum bending radius approx. 5x cable thickness Radiation resistance up to 50x0 6 cj/kg (up to 50 Mrad) Bare copper, extra fine wire conductors according to DIN VDE 0295 Kl. 6 and IEC cl. 6, BS 6360 cl. 6 Special rubber core insulation Core identification up to 5 cores to colour code DIN VDE cores and above with number printing Cores screened individually Cores laying parallel Copper screen, approx. 85% coverage Special Neoprene outer jacket black Outer jacket cold resistant Extensively oil resistant Extremely small bending radius High flexibility Minimum waste of space Packeting possibility The high degree of screening density assures disturbance-free transmission of all signal and impulses Outer dimension G x G x G x Outer dimension G x G x G x

46 TRAGO / Lift-2S Lift and Hoist Control Cables 300/500V Technical data Lift hoist control cables with strain bearing element Special PVC-compound for core and jacket, adapted to DIN VDE 0250 Temperature range flexing -5 C to +40 C fixed installation -40 C to +70 C Max. conductor temperature under load +70 C circuit conditions +50 C Nominal voltage U0/U 300/500 V Test voltage 3000 V Breakdown voltage min V Free suspension height max. 50 m Minimum bending radius approx. 20x cable Ø Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 6, BS 6360 cl. 6 and IEC cl. 6 Special PVC core insulation, YI3 to DIN VDE 0207 part 4 Core coding to DIN VDE 0293 Green-yellow earth core Special hemp support braid for Trago type with central support core of hemp for Lift-2S type with 2 outer steel support wires Cores stranded in layers with optimal lay-length Multi-layer wrapping functioning as a support braid Special PVC outer jacket YM2 to DIN VDE 0207 part 5 Colour black (RAL 9005) PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Note Art.no C = 2 cores 0,5 mm² with copper braiding. Art.no. 250 = 7G + 7x0,75 mm². G = with green-yellow earth core. AWG sizes are approximate equivalent values. The actual cross-section is in mm². These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for these cables has made them ideal even for use under extreme conditions. HELUKABEL -Lift-2S has also proven itself to be ideally suited for installation in conveyor systems and manual control units. The external steel support wires can be dismounted without damaging the cable insulation. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Trago ca. Support Core Pendal Length ca.m G Hemp G Hemp G Hemp G Hemp G Hemp G + 7 x Hemp G Hemp G Hemp G Hemp G Hemp G Hemp G Hemp 90 7 Lift-2s ca. Support Core Pendal Length ca.m G Steel G Steel G Steel G Steel G Steel G Steel G Steel G Steel G Steel G Steel

47 NSHTÖU drum cable, VDE approved Technical data Special crane-drum cable to DIN VDE 0250 part 84 Temperature range Tinned copper fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC cl. 5 flexing -35 C to +70 C Rubber core insulation GI to DIN VDE 0207 fixed installation -40 C to +70 C part 20 Max. conductor temperature Core identification to DIN VDE 0293, 6 cores under load +60 C and above with numbering circuit conditions +200 C Cores stranded (without elongated central Nominal voltage U0/U 0,6/ kv core) with max. lay-length of 8xØ over the Max. permissiblenominal voltages stranding layers for three phase and one phase a.c. Suspension strains as strain relieving current installation U0/U 0,7/,2 kv elements for direct current U0/U 0,9/,8 kv Textile tape Test voltage 2500 V Textile braiding as protection against Insulation resistance torsion, embedded in inner filling sheath min. 0 MOhm x km Neoprene outer jacket, type 5GM2 to Minimum bending radius DIN VDE 0207 part 2 7,5x cable Ø Jacket colour black Radiation resistance up to 20x0 6 cj/kg (up to 20 Mrad) Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional stress, for building machinery, conveyors, shifts and cranes. They are used as robust and all weather resistant cables for the roughest operations in mining and in flexible handling equipment and railway motors. The cables are suitable for outdoor installation in dry, damp and wet places. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Designed and developed for trailing use Permissible running speed up to 20 m/min max. Polychloroprene-rubber (neoprene)-jacket, extremely cold resistant Behaviour in fire Test according to , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) Oil resistant Test according to VDE 0472 part 803, test method A Due to the neoprene outer jacket, the cables are resistant against ozone and radiation, oils, acids, fats, gazoline, solvents and chemicals During the installation and operation the tensile stress on conductor may not increase 5 N/mm² Accelaration not more than 0,4 m/sec² While using to 2 convolutions it should remain on the operated drum In case of high mechanical stress, especially of high dynamic tensile stress resulting in accelaration, the permissible stress must high be defined in each case Note G = with green-yellow earth core. AWG sizes are approximate equivalent values. The actual cross-section is in mm². Outer G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G / G /0 50

48 TROMMELFLEX PUR trailing and control cable, halogen-free Technical Data Special PUR insulation and jacket Adapted to DIN VDE 0250 Strain bearing support strand Temperature range -40 C to +80 C (up to +00 C for short periods) Nominal Voltage up to mm² U0/U 300/500 V as of,5 mm² U0/U 450/750 V Test Voltage up to mm² = 2000 V as of,5 mm² = 2500 V Breakdown Voltage up to mm² = 4000 V as of,5 mm² = 5000 V Insulation Resistance min. 20 MOhm x km Minimum bending radius approx. 0x cable Ø Radiation resistance up to 00x0 6 cj/kg (up to 00 Mrad) Cable Structure Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 6, col. 4,BS 6360 cl. 6 and IEC cl. 6 Special core insulation, PUR Support core Core coding to DIN VDE 0293 (flexible cables) Cores stranded in layers with optimal lay length Core wrapping with fleece Support braiding of synthetic fibres Halogen-free outer jacket PUR Also available in black High flexibility at low temperatures Usable for foodstuffs Abrasion and tear resistant Loadable under torsional stress Resistant to Oils and fats Non-alcoholic fuels and kerosene Atmospheric influences UV-radiation Oxygen and ozone Microbes and rotting Sea and waste water Vibrations Note G = with green-yellow earth core. AWG sizes are approximate equivalent values. The actual cross-section is in mm². TROMMELFLEX-PUR has taken the development of the neoprene type cables one step further. It is a robust, all-weather cable, that is halogen-free, tear and abrasion resistant and suitable for use in drag-chains, in ship docks, on building sites, for conveyor systems, in mining, for tunnels and roadbuilding. Suitable for connecting the ski lift terminal positions to the control unit, surveillance of the joining rods in ski lift cables, as feeder cables for very high currents, as for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergency power generators etc. = The product conforms with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Breaking Strain ca. kp G G G G G G G G G G G G G G G G G G G G G G G G G

49 TRONIC (LiYY) flexible, colour coded to DIN 4700, TRONIC (LiYY) flexible, colour coded to DIN 4700, Technical data Special PVC data cables, adapted to Bare copper, fine wire conductors, bunch DIN VDE 0245, 082 stranded to DIN VDE 0295 cl. 5 and Temperature range IEC cl. 5 flexing -5 C to +80 C Conductor make-up for fixed installation -40 C to +80 C 0,4 mm² = 8x0, mm Nominal voltage 0,25 mm² = 4x0,5 mm 0,4 mm² = 350 V 0,34 mm² = 7x0,25 mm 0,25 mm² = 500 V Special PVC core insulation TI2, to Test voltage DIN VDE 028 part up to 0,25 mm² 200 V Colour coded to DIN 4700, but without from 0,34 mm² 2000 V colour repetition Breakdown voltage up to 0,25 mm² 2400 V from 0,34 mm² 4000 V Insulation resistance min. 20 MOhm x km Capacitance (approx.-value) at 800 Hz 0,4 mm² 20 pf/m 0,25 mm² 50 pf/m Inductance approx. 0,65 mh/km Impedance approx. 78 Ohm Minimum bending radius flexing 7,5x cable Ø fixed installation 4x cable Ø Cores stranded in layers with optimal lay-length Special PVC outer sheath TM2, to DIN VDE 028 part Colour grey (RAL 700) Extremely oil resistant. PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free contain no silicone and are free from substances harmful to the wetting properties of lacquers s These cables are used for flexible use with free movement, without tensile stress or forced movements in dry, moist or wet rooms but are not suitable for open air. When ever the construction requirements call for a minimum outer diameter. Tronic is the suitable cable to use. This applies especially to such areas as tool making and machine industries as well as electronic computer measurement and control sectors. = The product is conformed with the EC Low voltage directive 2006/95/EG x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

50 TRONIC-CY (LiY-CY) TRONIC-CY (LiY-CY) flexible, Cu-screened, colour coded to DIN 4700, EMC-preferred type flexible, Cu-screened, colour coded to DIN 4700, EMC-preferred type Technical data Special PVC data screened cables, adapted to DIN VDE 0245, 082 Temperature range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage 0,4 mm² = 350 V 0,25 mm² = 500 V Test voltage core/core 200 V core/screen 800 V Breakdown voltage min V Insulation resistance min. 200 MOhm x km Inductance approx. 0,65 mh/km Impedance approx. 78 Ohm Coupling resistance max. 250 Ohm/km Minimum bending radius flexing 0x cable Ø fixed installation 5x cable Ø x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Bare copper, fine wire conductors for Extensively oil resistant. 0,5 mm² to DIN VDE 0295 cl. 5 and IEC PVC self-extinguishing and flame retardant cl. 5 according to VDE , DIN EN Conductor make-up for / IEC (equivalent 0,4 mm² = 8x0, mm DIN VDE 0472 part 804 test method B) 0,25 mm² = 4x0,5 mm The materials used in manufacture are 0,34 mm² = 7x0,25 mm cadmium free, contain no silicone and are Special PVC core insulation TI2, to free from substances harmful to the DIN VDE 028 part wetting properties of lacquers Cores stranded in layers with optimal lay length EMC = Electromagnetic compatibillity Colour coded to DIN 4700, but without To optimise the EMC features we recommend colour repetition Core wrapping with foil a large round contact of the copper Drain-wire, tinned braiding on both ends. Tinned, copper braided screen, approx. 85% coverage Special PVC outer sheath TM2, to DIN VDE 028 part Colour grey (RAL 700) These screened cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies especially to such areas such as tool making and machine industries as well as electronic, computer, measurement and control sectors x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

51 PAAR-TRONIC-CY flexible, Cu screened, colour coded to DIN 4700, EMC-preferred type Technical data Special PVC data cables, adapted to DIN VDE 082, 084 Temperature range flexing -5 C to +80 C fixed installation -30 C to +80 C Operating voltage 350 V (not for purposes of high current and power installation) Test voltage core/core 200 V core/screen 800 V Breakdown voltage min V Insulation resistance Load at 0,4 mm² =,5 A at 0,25 mm² = 2,5 A at 0,34 mm² = 4,5 A at 0,50 mm² = 6 A at 0,75 mm² = 9 A Inductance approx. 0,65 mh/km Impedance approx. 78 Ohm K-coupling approx. 300 pf/00 m Coupling resistance max.250 Ohm/km Minimum bending radius flexing 0x cable Ø fixed installation 5x cable Ø x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl. 5, 0245 and IEC cl. 5 Conductor make-up for 0,4 mm² = 8x0, mm 0,25 mm² = 4x0,5 mm 0,34 mm² = 7x0,25 mm Special PVC core insulation YI2, to DIN VDE 0207 part 4 Colours coded to DIN 4700 with colour repetition Cores stranded in pairs with optimal lay length Pairs stranded in layers with optimal lay length Core wrapping with foil Tinned copper braided screening, coverage approx. 85% Special PVC outer sheath YM2, to DIN VDE 0207 part 5 Sheath colour grey (RAL 7032) Extensively oil resistant. Chemical Resistance - see Technical Information table PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry moist and wet rooms but not suitable for open air. PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially reduces the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an earth. The twisted pairs conform favourable cross-talk attenuation values. These cables are suitable for dry and wet rooms. yet not for open air. EMC = Electromagnetic compatibility = The product is conformed with the EC Low-Voltage Directive 2006/95/EG x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x

52 BUS Cables PROFIBUS L2 Indoor Type Inner conductor diameter: Core insulation: Core colours: Stranding element: Shielding : Shielding 2: Total shielding: Outer sheath material: Cable external diameter: Outer sheath colour: Fixed installation, indoor x2x0.64 mm Copper, bare (AWG 22/) Foam-skin-PE rd, gn 2 cores + 2 fillers stranded together Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned PVC approx. 7,8 mm ± 0,2 mm Grey similar to RAL 700 Fixed installation, indoor x2x0.64 mm Copper, bare (AWG 22/) Foam-skin-PE rd, gn 2 cores + 2 fillers stranded together Polyester foil over stranded bundle Polyester foil, aluminium-lined Cu braid, tinned PVC approx. 7,8 mm ± 0,2 mm Violet similar to RAL 400 Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Test voltage: Attenuation: 50 Ohm ± 0 % 50 Ohm ± 0 % 55,0 Ohm/km max. 55,0 Ohm/km max.,00 GOhm x km min.,00 GOhm x km min. 30,0 nf/km nom. 30,0 nf/km nom.,5 kv,5 kv 9,6 khz < 2,5 db/km 9,6 khz < 2,5 db/km 38,4 khz < 4,0 db/km 38,4 khz < 4,0 db/km 4 MHz < 22,0 db/km 4 MHz < 22,0 db/km 6 MHz < 42,0 db/km 6 MHz < 42,0 db/km Technical data : Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight: Norms Applicable standards: UL Style: approx. 69,0 20,0 mm -40 C +70 C 0,99 MJ/m 24,0 Profibus acc. to DIN 9245 T3 and EN5070 UL Style 257 approx. 69,0 20,0 mm -40 C +70 C 0,99 MJ/m 24,0 Profibus acc. to DIN 9245 T3 and EN5070 UL Style 257 This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the information exchange between different automation systems as well as for communication with the connected decentralized field units, serial field bus systems are used. The types mentioned here are suitable for indoor laying and are equipped with a special PVC sheath. no. Dimensions and specifications may be changed without prior notice , Profibus L2 8448, Profibus L2 55

53 BUS Cables CAN Bus Type Inner conductor diameter: Core insulation: Core colours: Stranding element: Shielding : Shielding 2: Total shielding: Outer sheath material: Cable external diameter: Outer sheath colour: Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Nominal voltage: Test voltage: Technical data : Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight: Norms Applicable standards: UL Style: Fixed installation, indoor x2x0.22 mm² (stranded) Copper, bare (AWG 24/7) Cell PE wh/bn Double core Polyester foil over stranded bundle - Cu braid, tinned PVC approx. 5,4 mm ± 0,2 mm Violet similar to RAL Ohm ± 0,00 % 87,0 Ohm/km max.,00 GOhm x km min. 58,0 nf/km nom. 30 V,5 kv approx. 35,0 8,0 mm -40 C +70 C 0,57 MJ/m 6,0 Profibus acc. to DIN 9245 T3 and EN5070 UL Style 257 Fixed installation, indoor 4xx0.22 mm² (stranded) Copper, bare (AWG 24/7) Cell PE wh, bn, gn, ye Star quad Polyester foil over stranded bundle - Cu braid, tinned PVC approx. 6,9 mm ± 0,2 mm Violet similar to RAL Ohm ± 0,00 % 87,0 Ohm/km max.,00 GOhm x km min. 58,0 nf/km nom. 30 V,5 kv approx. 60,0 07,0 mm -40 C +70 C,23 MJ/m 2,0 Profibus acc. to DIN 9245 T3 and EN5070 UL Style 257 The CAN bus series (control area network) is a variable field bus system. In the area of automation technology, complex controllers and control units are networked. Industries, such as the textile or construction machine industry and the medical technology, use this series. The above mentioned types are suitable for fixed laying in indoor applications. This is also a very economical solution of a BUS system. no. Dimensions and specifications may be changed without prior notice. 8286, CAN BUS 8287, CAN BUS 56

54 BUS Cables DeviceNet PVC Drop & Trunk Type Inner conductor diameter : Inner conductor diameter 2: Core insulation : Core insulation 2: Core colours : Core colours 2: Stranding element : Shielding : Shielding 2: Total shielding: Drain wire: Outer sheath material: Cable external diameter: Outer sheath colour: Electrical data Characteristic impedance: Conductor resistance: Insulation resistance: Mutual capacitance: Test voltage: Attenuation: Technical data : Min. bending radius for laying: Operating temperature range min.: Operating temperature range max.: Caloric load, approx. value: Copper weight: Norms Applicable standards: UL Style: CSA standard: Fixed installation, indoor x2xawg8 + x2xawg5 Copper, tinned (AWG 8/9) Copper, tinned (AWG 5/9) Foam-skin-PE PVC light bu, wh rd, bk Double core - Polyester foil, aluminium-lined Cu braid, tinned yes PVC approx. 2,2 mm ± 0,3 mm Grey 20 Ohm ± 0 % 22,6 Ohm/km max. 0,20 GOhm x km min. 39,8 nf/km nom. 2,0 kv 25 khz < 0,42 db/00m 500 khz < 0,8 db/00m approx. 92,0 90,0 mm -20 C +80 C 2,92 MJ/m 85,0 ODVA DeviceNet CMG 75 C PLTC FT4 CEC: CMG FT4 Fixed installation, indoor x2xawg24 + x2xawg22 Copper, tinned (AWG 24/9) Copper, tinned (AWG 22) Foam-skin-PE PVC light bu, wh rd, bk Double core - Polyester foil, aluminium-lined Copper shifting, tinned yes PVC approx. 6,9 mm ± 0,3 mm Grey 20 Ohm ± 0.0 % 90,0 Ohm/km max. 0,20 GOhm x km min. 39,8 nf/km nom. 2,0 kv 25 khz < 0.95 db/00m 500 khz <.64 db/00m approx. 67,0 0,0 mm -20 C +80 C 0,9 MJ/m 35,0 ODVA DeviceNet CMG 75 C PLTC FT4 CSA FT 4 DeviceNet is a bus system developed by Allen Bradley (Rockwell Automation). These cables are used to interconnect various industrial devices, such as SPS controls or limit switches. The special characteristic of this bus system is that a data pair and a power supply pair are integrated in one cable. These cables with PVC sheath are designed for fixed installation. no. Dimensions and specifications may be changed without prior notice , DeviceNet PVC THICK , DeviceNet PVC THIN 57

55 MACHLINK INSTRUMENTATION CABLE Appications The MACHLINK instrumentation cables described in this catalogue are manufactured strictly based on the requirement of Underwriters Laboratories (UL) as well as relevant Australian Standards. MACHLINK Instrumentation cables are mainly used in data processing and process control i.e. electrical measuring device to instrument panel. instrument to instrument connection, and electrical sensing device to control cabinets. It can be used also for general transmission of electrical signals in any systems of remote control, indication, telemetering, monitoring and analysis which it needs to be protected from interference to the transmission signal by other electrical circuits. Instrumentation cable with the identification colour blue is specified for intrinsically safe circuits use. Cable configuration Conductor: Plain annealed copper (class 2 strands) of the type specified in AS/NZS 25. ed and colour coded high grade polyvinyl chloride (PVC 90 C) compounds insulation to UL Style Insulation: 569. Laying-up core: Twisted to pair or triple with optimum pitch to minimise the cross talk. A stranded tinned annealed copper drain wire (7/0.2mm) is helically applied between the lapping polyester tape and the aluminium foil (00% coverage) for extra protection against external noise and Overall screened: interference (i.e. electrostatic from external high voltages and electromagnetic from external high currents) Bedding and sheath: High grade (PVC 90 C) Flame retardant to UL Style Sheath identification: Core identification to UL Style 2464: Laying-up core: Operating temperature Black sheath (Ultraviolet - UV stabilised) - standard type instrumentation cable to UL Style 2464 Blue sheath - instrumentation cable for intrinsically safe circuit to AS Pair element: Triple element: Black, White, and all cores numbered Black, White, Red, and all cores numbered Twisted to pair or triple with optimum pitch to minimise the cross talk. Minimum conductor continuous operating temperature: -25 C Permanent continuous conductor operating Temperature: 75 C Maximum conductor operating temperature: 90 C Short circuit temperature for 5 sec: 60 C --Flame retardant PVC is tested to standard IEC 332-3A. Physical & Electrical Test Voltage: Rated Voltage: Nominal Voltage: In-process spark test V and A.C withstand voltage test - 500V Max. 300V a.c 0V a.c / 50V d.c Nominal CSA Nominal Conductor Diameter Maximum Conductor 20 C Approximate current carrying capacity Fault Current for sec Insulation Max capacitance Cond. to Cond. (screened) Max. capacitance Cond. to Scr. (screened) Max capacitance Cond. to Cond. (unscreened) 0.50 mm² 0.87 mm 38.4/km 2 ~ 3.5 A 70 A 40MΩ.km 45pF/m 240pF/m 82pF/m 0.75 mm².08 mm 24.5/km 3 ~ 7.5 A 05 A 40MΩ.km pF/m.00 mm².4 mm 8./km 4 ~ 0 A 40 A 40MΩ.km pF/m.50 mm².47 mm 3.6/km 5 ~ 3. A 20 A 40MΩ.km 200pF/m 300pF/m 0pF/m Nominal CSA Cross talk attenuation between khz (screened) Cross talk attenuation between khz (unscreened) Attenuation of Attenuation of pairs khz khz Ω terminations 600 Ω terminations (unscreened) (screened) Characteristic khz (screened) Characteristic khz (unscreened) khz L/R 0.50 mm² >25dB/00m >90dB/00m 0.09dB/00m 0.dB/00m 300 Ω 380 Ω.00mH/km 3.7μH/ Ω 0.75 mm² >25dB/00m >90dB/00m 0.09dB/00m Ω 0.98mH/km 20.0μH/ Ω.00 mm² >25dB/00m >90dB/00m 0.08dB/00m Ω 0.97mH/km 27.7μH/ Ω.50 mm² >25dB/00m >90dB/00m 0.08dB/00m 0.09dB/00m 50 Ω 200 Ω 0.95mH/km 36.5μH/ Ω Mechanical Operating Temperature The recommended bending radius is as follows: Unarmoured Cable: 9 x Cable Outer Diameter (during installation) Minimum conductor continous operating temperature: -25 C 6 x Cable Outer Diameter (after installation) Permanent continous conductor operating temperature: 75 C Armoured Cable: 8 x Cable Outer Diameter (during installation) Maximum conductor operating temperature: 90 C 2 x Cable Outer Diameter (after installation) Short circuit temperature for 5 seconds: 60 C 58

56 Overall Screened, Pairs PVC 90C White Black White 4 Black White Black White 5 Black 4 2 White 2 Black Nominal Area mm 2 (AWG) No of Pairs 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA TA TA TA (8) TA (7/0.40mm) TA TA Nominal Area mm 2 (AWG) No of Pairs.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA TA TA Overall Screened, Armoured Pairs Nominal Area mm 2 (AWG) No of Pairs 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Pairs.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA

57 Individual & Overall Screened, Pairs PVC 90C White Black White White White Black 4 Black 5 Black White Black Nominal Area mm 2 (AWG) No of Pairs 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Pairs.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA TA Individual & Overall Screened, Armoured Pairs Nominal Area mm 2 (AWG) No of Pairs 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Pairs.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA TA

58 3 Red White Black 5 Overall Screened, Triads PVC 90C White White Red 2 Black Red 6 Black White Black White Black Red 3 3 White 4 Red Black Red Nominal Area mm 2 (AWG) No of Triads 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Triads.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA TA Overall Screened, Armoured, Triads Nominal Area mm 2 (AWG) No of Triads 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Triads.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA TA

59 Individual & Overall Screened, Triads Nominal Area mm 2 (AWG) No of Triads 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Triads.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA Individual & Overall Screened, Armoured, Triads Nominal Area mm 2 (AWG) No of Triads 0.5 (20) TA (7/0.30mm) TA TA TA TA TA TA TA TA TA TA Nominal Area mm 2 (AWG) No of Triads.5 (6) TA (7/0.50mm) TA TA TA TA TA TA TA TA TA TA

60 SUPERTRONIC -PVC special cable for drag chains, meter marking Technical data Special PVC cable for drag chains, adapted to DIN VDE 0245, 028 Very high flexibility due to special construction DIN VDE 028 part Temperature range flexing -5 C to +70 C fixed installation -40 C to +70 C (short time +05 C) selected lay length Nominal voltage 350 V Test voltage 500 V Breakdown voltage min V DIN VDE 028 part Insulation resistance min. 20 MOhm x km Bare copper, extra fine wire conductors, to DIN VDE 0295 cl. 6 col. 4 and 5 Special PVC core insulation TI2, to Minimum bending radius flexing 5x cable Ø fixed installation 3x cable Ø Radiation resistance up to 80x0 6 cj/kg (up to 80 Mrad) Cores colour coded to DIN 4700, see Technical Information Cores stranded in layers with optimal Core wrapping with textile tape Special PVC outer sheath TM2, to Colour grey (RAL 700) With meter marking, change-over in 2009 Extensively oil resistant Chemical Resistance - see Technical Information table Adhesion-free PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries, robotics and all areas of highly mobile machine parts. The long working life offers a secure performance and is economical. for applications which go beyond standard solutions (for example, for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend our specially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. For further technical details see lead in text selection table for drag chain cables. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Dimensions and specifications may be changed without prior notice. (RC03) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

61 SUPERTRONIC -C-PVC special cable for drag chains, EMC-preferred type, meter marking Technical data Special PVC cable for drag chains, adapted Bare copper, extra fine wire conductors, to to DIN VDE 0245, 028 DIN VDE 0295 cl. 6 col. 4 and 5 Very high flexibility due to special Special PVC core insulation TI2, to construction DIN VDE 028 part Temperature range Cores colour coded to DIN 4700, see flexing -5 C to +70 C Technical Information fixed installation -40 C to +70 C Cores stranded in layers with optimal (short time +05 C) selected lay length Nominal voltage 350 V Core wrapping with textile tape Test voltage 500 V Tinned copper braided screen, approx. 85% Breakdown voltage min V coverage are Insulation resistance Special PVC outer sheath TM2, to min. 20 MOhm x km DIN VDE 028 part Minimum bending radius Colour grey (RAL 700) flexing 7,5x cable Ø With meter marking, change-over in 2009 fixed installation 4x cable Ø Radiation resistance up to 80x0 6 cj/kg (up to 80 Mrad) Coupling resistance max. 250 Ohm/km Extensively oil resistant Chemical Resistant - see Technical Information table Adhesion-free PVC self-extinguishing and flame retardant according to VDE , DIN EN / IEC (equivalent DIN VDE 0472 part 804 test method B) The materials used in manufacture are cadmium-free, contain no silicone and free from substances harmful to the wetting properties of lacquers Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries, robotics and all areas of highly mobile machine parts. The long working life offers a secure performance and is economical. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc), we recommend our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see lead in text selection table for drag chain cables. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Dimensions and specifications may be changed without prior notice. (RC03) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

62 SUPERTRONIC -PURö special cable for drag chains, meter marking Technical data Special PUR drag chain cables adapted to Bare copper, extra fine wire conductors, to Features DIN VDE 028 part 3 DIN VDE 0295 cl. 6, col. 4 and 5, cl. 6 and High flexibility at low temperature, high Very high flexibility due to special IEC cl. 6 abrasion resistance, break and cut-resistance construction Oil resistant PVC core insulation TI2, in tear resistant and flame retardant. Temperature range adapted to DIN VDE 028 part, for better Resistant to UV-radiation, Oxygen, Ozone, flexing -5 C to +70 C sliding abilities Hydrolyse, Oil. fixed installation -40 C to +70 C Cores are stranded in layer with short Conditional resistance to Microbes, Nominal voltage 350 V lay length Hydraulic liquidity, Alkalis and Lye. Test voltage 500 V Cores colour coded to DIN 4700 The PUR outer jacket is extremely robust Breakdown voltage min V Core wrapping with textile tape with high tear, abrasion and oil-resistance. Special full-polyurethane outer jacket Adhesion-free. Insulation resistance min. 20 MOhm x km TMPU to DIN VDE 0282 part 0, appendix A The materials used in manufacture are Outer jacket grey (RAL 700), surface mat cadmium-free, contain no silicone and Minimum bending radius flexing 5x cable Ø With meter marking, change-over in 2009 are free from substances harmful to the fixed installation 3x cable Ø wetting properties of lacquers Radiation resistance up to 00x0 6 cj/kg (up to 00 Mrad) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². Perfect for use with cable trays. This highly flexible and screened PUR control cable is ideal for use wherever frequent high flexing motion is required, e.g. in robotics or all moving parts. The long working life of this cable makes it both efficient and economic. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc), we recommend our specially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. For further technical details see lead text in selection table for drag chain cables. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Dimensions and specifications may be changed without prior notice. (RC03) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

63 SUPERTRONIC -C-PURö special cable for drag chains, halogen-free, EMC-preferred type, meter marking Technical data Special PUR drag chain cables, screened, in Plain copper conductors extra fine wire Features adapted to DIN VDE 028 part 3 stranded to DIN VDE 0295 cl. 6, col. 4 and High flexibility at low temperature, high Temperature range 5, IEC cl. 6 abrasion resistance, break and cut-resistant, flexing -40 C to +70 C Oil resistant TPE core insulation tear resistant and flame retardant. fixed installation -50 C to +70 C Cores are stranded in layer with short Resistant to UV-radiation, Oxygen, Ozone, Nominal voltage lay length Hydrolyse, Oil. 0,4 mm² 350 V Cores colour coded to DIN 4700 Conditional resistance to Microbes, 0,25 and 0,34 mm² 500 V Core wrapping with textile tape Hydraulic liquidity, Alkalis and Lye. Test voltage The PUR outer jacket is extremely robust Tinned copper screened braiding. Due to 0,4 mm² 800 V the technical facilities, the copper braiding with high tear, abrasion and oil-resistance. 0,25 and 0,34 mm² 200 V can be mixed and webed with a portion of Adhesion-free. Capacitance core/core <80 nf/km synthetic fibres The materials used in manufacture are Minimum bending radius cadmium-free, contain no silicone and Special full-polyurethane outer jacket flexing 7,5x cable Ø TMPU to DIN VDE 0282 part 0, appendix A are free from substances harmful to the fixed installation 4x cable Ø wetting properties of lacquers Outer jacket grey (RAL 700) Radiation resistance With m,eter marking, change-over in 2009 up to 00x0 Note AWG sizes are approximate equivalent values. The actual cross-section is in mm². Used for installation in dry, moist and wet environments as well as for outdoors, for free movement without forced motion, for flexible routing without forced motion, for proven use as drag-chain cables. Suitable as a highly flexible control cable for fast hoisting and bending stresses in machinery and tooling construction, in robotics engineering and for continuously moving machinery parts. The long working life of this cable makes it both efficient and economic. The copper braided screening offers effective protection from both internal and external interference. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc), we recommend our specially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. For further technical details see lead text in selection table for drag chain cables. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Dimensions and specifications may be changed without prior notice. (RC03) x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

64 SUPER-PAAR-TRONIC-C-PUR cable for drag chains, halogen-free, EMC-preferred type, meter marking Technical data Special PETP-PUR cable, twisted in Plain copper conductors, extra fine wire Very good oil resistance, test method pairs,adapted to DIN VDE 0245, 082 stranded to DIN VDE 0295 cl. 6, col. 4, according to DIN VDE 0472 part 803 Conductor and loop resistance as per BS 6360 cl. 6 and IEC cl. 6 Resistant to weather, ozone and DIN VDE 0295, for 0,25 mm² see Special core insulation of TPE, oil resistant UV-radiation Technical-Information page Core identification as per DIN 4700 Chemical resistant to solvents, acids, lyes Temperature range and hydraulic liquidity Cores twisted in pairs, the pairs torsion-free flexing -40 C to +70 C Stranded in layers Flame retardant fixed installation -50 C to +70 C Special fleece over outer layer Guaranteed permanent application in Nominal voltage 350 V multi-shift operation under extreme high Tinned copper screened braiding, approx. Test voltage 500 V 85% coverage bending stress Insulation resistance Highly resistant to mechanical strain Full-polyurethane outer jacket TMPU, to min. 00 MOhm x km DIN VDE 0282 part 0, appendix A High property of alternating bending Mutual capacitance Outer jacket grey (RAL 700) strength approx. 35 nf/km Long life durabilities through low With meter marking, change-over in 2009 Minimum bending radius friction-resistance by using the TPE-core flexing at 0,25 mm² insulation where the cores are stranded in approx. 7,5xcable Ø layers fixed installation at 0,25 mm² High tensile strength, abrasion and impact approx. 4xcable Ø resistant at low temperature flexing at 0,5-,0 mm² approx. 0xcable Ø Adhesion-low The materials used in manufacture are fixed installation at 0,5-,0 mm² cadmium-free, contain no silicone and approx. 5xcable Ø are free from substances harmful to the Coupling resistance wetting properties of lacquers max. 250 Ohm/km Radiation resistance Note up to 00x0 6 cj/kg (up to 00 Mrad) AWG sizes are approximate equivalent values. The actual cross-section is in mm². These pair stranded and overall screened special cables for drag chains offer the operational possibilities where the outer electrical influences at high frequency cause interference of impulse transmission and are applied for permanent flexible operations in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift-operation as a transmission-cable. These high flexible data cables are developed according to the newest state of technology improvement with its sliding abilities by using the PETP-core insulation and adhesion-low and cut-resistant PUR-outer jacket, guarantee an optimum life durabilities are highly economic. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see lead text in selection table for drag chain cables. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Dimensions and specifications may be changed without prior notice. (RC03) 90 x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x x 2 x

65 TOPSERV 0 / 20 / Feedback-Cable drag chain cable, 0,6/kV EMC-preferred type, servo/feedback cable, high flexible Technical data Special-PUR drag chain cable based on Plain copper conductor, ultra-fine wire DIN VDE 0295, 0250, 028 for TOPSERV 0: Temperature range mm² = 9x0,25 mm flexing -40 C to +90 C TPE core insulation, halogen-free fixed installation -40 C to +90 C Core identification: Nominal voltage Power supply cores black with imprint U, power supply cores U0/U 600/000 V V2, W3 and earth core green-yellow, control cores U0/U 300/500 V Control cores black with imprint BR, BR2 or nos. 5-6 and 7-8 for the 2-pair-version Test voltage power supply cores 4000 V control cores 000 V Power rating to DIN VDE 0298 part 4 Insulation resistance min. 20 MOhm x km Minimum bending radius flexing approx. 7,5x cable Ø fixed installation approx. 4x cable Ø Coupling resistance max. 250 Ohm/km Screening of the control cores in pairs with Al film, tinned drain wire and tinned Cu braid; single pair with tinned Cu braid only Control cores stranded in pairs and laid up in layers together with the power supply cores Fleece wrapping Overall screening of tinned cu braid, visible coverage min. 80% Fleece wrapping PUR-outer sheath, flame-resistant Colour petrol (RAL 508) With meter marking, change-over in 2009 PUR-outer sheath flame retardant, low adhesion, resistant to hydrolysis and microbial attack, halogen-free These highly flexible cables are fitted with an additional overall screen to assure EMC compatibility, i.e. the protection against electromagnetic interference The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers Note For extreme applications extending beyond standard solutions we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Please observe applicable installation regulations for use in energy supply chains. The combination of feeder cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors, as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements are met to a high degree as is the electromagnetic compatibility (EMC). These cables can also be used as drag chain cables. Manufacturing is based on specifications from renowned manufacturers of servo-actuators and servo-controls as well as in accordance with diverse VDE standards. for system SIMODRIVE. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. TOPSERV 0 ( pair screened and overall screening) 749 (4x.5+ (2x.0)) (4x 2.5+ (2x.0)) x 4+ (2x.0)) (4x 6+ (2x.0)) (4x 0+ (2x.0)) (4x 6+ (2x.0) (4x 25+ (2x.0)) (4x 35+ (2x.0)) (4x 50+ (2x.0)) TOPSERV 20 (2 pairs individually screened and overall screening) 7990 (4x.5+ 2x (2x.0)) (4x x (2x.0)) (4x 4+ 2x (2x.0)) (4x 6+ 2x (2x.0)) (4x 0+ 2x (2x.0)) (4x 6+ 2x (2x.0)) (4x 25+ 2x (2x.0)) (4x 35+ 2x (2x.0)) (4x 50+ 2x (2x.0)) TOPSERV Feedback-Cable (overall braid-screened) (deviation from TOPSERV ) AWGca. mm No (2x 0.25) (3x (2x 0.4)+ 4x x x 0.5) (4x 2x x 0.5) PVC-core insulation. cores colour coded. foil taped. PUR-jacket TPE-core insulation. cores colour coded. fleece wrapping. PUR-jacket PVC-core insulation. cores colour coded. foil taped. PUR-jacket 68

66 ROBOFLEX 200 / 200-C Robot cables Technical data Special TPE-E/PUR adapted to DIN VDE 0245, Bare copper, stranded to DIN VDE 0295 and High flexibility at low temperatures 0250, 0282 IEC 60228, fine or extra fine wires, cl. 5 or High abrasion resistance Temperature range flexing -30 C to +80 C cl. 6, BS 6360 cl. 5 or 6, up to 0,34 mm² cl. 5, above 0,5 mm² cl. 6 Loadable under torsion stress ±360 /meter Low adhesion fixed installation -40 C to +80 C Special core insulation, TPE Resistant to Nominal voltage up to 0,34 mm² 350 V (operating peak voltage) above 0,5 mm² U0/U 300/500 V Cores coded up to 0,34 mm² according DIN 4700 above 0.5mm² black cores with continuous white numbering according to DIN VDE 0293 Microbes and rotting Oxygene and ozone Vibrations UV-radiation Test voltage Green-yellow earth core in the outer layer Oil and fats resistant up to 0,34 mm²,5 kv, 5 minutes (3 cores and above) PUR-jacket flame retardant according to above 0,5 mm² 3,0 kv, 5 minutes Mutual capacitance core/core approx. 00 nf/km core/screen approx. 20 nf/km Inductance approx. 0,69 mh/km Minimum bending radius 7,5x cabel Ø Cores stranded in layers with optimal DIN VDE 0482 part / EN / lay length IEC (equivalent DIN VDE 0472 Special separating foil part 804 test method B) C-type, cu-screen of helically wound, approx % coverage Outher sheath, special polyurethane Colour black (RAL 9005) With meter marking, change-over in 2009 These special robotic control and signal cables are specially designed for torsion and bending stresses in robots and connecting handling tools. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. ROBOFLEX 200 ROBOFLEX G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G ROBOFLEX 200-C Screened G G G G G G G G G G G G G G G G G G G G G

67 PVC spiral cables Technical Data Temperature range -5 C to +70 C Nominal voltage H03VV-F 300/300V (up to mm2) H05VV-F 300/500V (up to.5mm2) Test Voltage 2000 V Expansion Ratio :3 Straight Ends 200/200 mm Cable Structure Bare copper, fine wire conductors to VDE 0295 cl. 5 PVC Core insulation Cores Stranded Cores colour coded to VDE 0293 PVC outer sheath Note AWG sizes are approximate equivalent values. The actual cross section is in Also in coaxial construction On request closed spiral lengths up to max 5000 mm possible. PUR spiral cables orange Technical Data Temperature range -25 C to +70 C Nominal voltage H05BQ-F 300/500V (up to mm2) H07BQ-F 450/750V (up to.5mm2) Test Voltage 2000/2500 V Expansion Ratio :4 Straight Ends 200/200 mm Cable Structure PLAIN copper, fine wire conductor fine wire stranded EPDM Core insulation VDE approved cable PUR outer sheath Sheath colour orange Note AWG sizes are approximate equivalent values. The actual cross section is in Also in axial construction On request closed spiral lengths up to max 5000 mm possible. Spiral Cables can be customised to suit your requirements. In-house manufacturing allows for short lead times. 70

68 The perfect wire for solar modules Our SOLARFLEX -X PV-F cable has TÜV and VDE certifications and is manufactured to the highest quality standards. The wire is used globally in stand-alone and networked systems as a module or branch wire. Both insulation layers are set-off coloured from each other for improved handling: black sheathing on natural colour conductor insulation is the standard version, or optionally, red or blue sheathing to simplify local installation. A version designed as a twin wire is also available. Technical Data temperature range -40 C to +90 C max. temp. at conductor +20 C Nominal voltage according to VDE U 0/U 600/000 V AC 800 V DC conductor / conductor AC test voltage 4000 V, 50 Hz Minimum bending radius for fixed installation approx. 4x cable Ø Bare copper, tinned, finely stranded According to DIN VDE 0295 Class 5 and IEC cl. Double-insulated Insulation cross-linked special compound Outer sheath cross-linked special compound Sheath colours: black, red, blue Approval: VDE, TÜV (2 PfG 69/ ) UV, ozone, weather and hydrolysis-resistant Halogen-free acc. to DIN VDE 0482 part 267 Good resistance to oils and chemicals Flame-resistant according to VDE , DIN EN , IEC Anticipated service life - 25 years RoHS conformity No. cores x cross-sec. mm² app. mm Cop. weight kg / km app. kg / km x x x x x x x x x x Solarflex 7

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables The BIG names in Cable for the BIG jobs in Cable Treotham Automation is the exclusive distributor for the biggest names in the cable industry. Each office keeps a stock of the most popular items These

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

Industrial Cables and Wires

Industrial Cables and Wires HELUKABEL Products are available from MARYLAND METRICS P.O. Box Owings Mills, MD USA web: http://mdmetric.com ph: ()35-330 (00)3-30 fx: ()35-3 (00)7-939 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm

More information

MOTOR, SERVO, & FEEDBACK CABLES

MOTOR, SERVO, & FEEDBACK CABLES MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free

More information

Selection table for heat-resistant cables

Selection table for heat-resistant cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for heat-resistant cables www.helukabel.com HEAT-RESISTANT

More information

Photo: HELUKABEL. Trailing Cables G 1

Photo: HELUKABEL. Trailing Cables G 1 Photo: HELUKABEL Trailing Cables G 1 Trailing Cables Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

H05 V-K PVC-Single Cores, fine wire stranded

H05 V-K PVC-Single Cores, fine wire stranded H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description. H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial

More information

PUR c-track cables For highest requirements

PUR c-track cables For highest requirements 2. C-track cables PUR c-track cables For highest requirements LÜTZE SUPERFLEX PLUS N PUR UL 300 V Machine and device construction, transport and conveyor technology Through full PUR jacket and TPE conductor

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

Technical attributes

Technical attributes Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,

More information

Ship Wiring and Marine Cables

Ship Wiring and Marine Cables Ship Wiring and Marine Cables Photo: HELUKABEL Ship Wiring and Marine Cables 1 Ship Wiring and Marine Cables We offer ship wiring and marine cables with approvals from Germanischer Lloyd, Lloyds Register

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

Due to the increasing data transfer between machines and equipment the higher standards in data and computer applications are necessary.

Due to the increasing data transfer between machines and equipment the higher standards in data and computer applications are necessary. HI TECH CONTROLS' INC. _ Data and computer Cables Due to the increasing data transfer between machines and equipment the higher standards in data and computer applications are necessary. Besides standard

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE... Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter A A 146 FRN A A 156 FRN Halogen-free wiring with improved fire performance and extended temperature range 300/500

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination 2013 Product Catalogue Industrial Cables Hazardous area equipment Cable termination KabEx Australia is a leading company specializing in the supply of cables, hazardous area equipment and cable termination

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Cables for cable carriers and reels SYSTEMS IN MOTION

Cables for cable carriers and reels SYSTEMS IN MOTION Cables for cable carriers and reels SYSTEMS IN MOTION 8e/en 2016 Content PVC flatform cables (H)07VVH6-F H07VVH6-F... 4 PVC flatform cables, shielded YCFLY... 6 Neoprene flatform cables NGFLGÖU UL... 8

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE...

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE... Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter Halogen-free single A A 146 FRN A A 156 FRN Halogen-free single conductor with improved fire performance and extended

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

DKSH provides expertise and solutions to industry

DKSH provides expertise and solutions to industry Business Unit Technology DKSH provides expertise and solutions to industry Industrial Services Australia Our Profile Locations VICTORIA (Head Office) 14-17 Dansu Court Hallam VIC 3803 Tel: +61 3 9554 6666

More information

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination 2011 Ver 1.1 Product Catalogue Industrial Cables Hazardous area equipment Cable termination KabEx Australia is a leading company specializing in the supply of cables, hazardous area equipment and associated

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

Selection table for data and computer cables

Selection table for data and computer cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for data and computer cables www.helukabel.com DATA & COMPUTER

More information

PVC motor cables unshielded

PVC motor cables unshielded PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics ENERGY TECSUN(PV) PV1 F Cables for Photovoltaics Technical Data Electrical Thermal Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / DE TECSUN (PV)

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM) CORDAFLEX (SM) Portable reel cable EP insulation, dual neoprene jacket with braid reinforcement, 90 C, 600 volts Rack and pinion elevators using sheave guided cables Container crane spreader reels Timber

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

SY PVC / BS EN Control Flexible Cable

SY PVC / BS EN Control Flexible Cable SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

ENERGY. Solar Cables

ENERGY. Solar Cables ENERGY Solar Cables Contents TECSUN(PV) PV1-F Cables for Photovoltaics 3 Technical Data 4 Design Features 6 Selection and Ordering Data 6 TECSUN DUO (PV) Cables for Photovoltaics 7 Technical Data 8 Design

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire Low voltage - Energy, cabling, signalling and control TRIFLEX H07RN-F Structure and, physical, mechanical requirements: Low Directive: RoHS Directive: EN 50525-2-21 2014/35/EU 2011/65/EU Standard: Class:

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

Data sheet chainflex CF10

Data sheet chainflex CF10 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Industry Cables Special cables for industrial applications General Catalogue

Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the

More information

Data sheet chainflex CF140.UL

Data sheet chainflex CF140.UL 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight

More information

A SAFE CONNECTION EVERY STEP OF THE WAY Cables / Cable protectors

A SAFE CONNECTION EVERY STEP OF THE WAY Cables / Cable protectors 10 - Cables / Cable protectors A SAFE CONNECTION EVERY STEP OF THE WAY. Whether dry or wet, whether for connecting small devices or large machines: Electrical cables from GIFAS meet every challenge, from

More information

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

Data sheet chainflex CF5

Data sheet chainflex CF5 1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:

More information

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

Cable systems We offer you the essential components for a future-oriented e-mobility.

Cable systems We offer you the essential components for a future-oriented e-mobility. Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent

More information

CF11.LC / CF11.LC.D CF14.CAT5

CF11.LC / CF11.LC.D CF14.CAT5 TPE - e-chain - Bus cable for maximum load requirements (Class 6.6.4): shielded, oil- and biooil-resistant, PVC- and halogen-free as well as hydrolysis- and microbe-resistant. Overview Example drawing

More information

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES * october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent

More information

Kabel CONNECTION. A partnership to your advantage.

Kabel CONNECTION. A partnership to your advantage. Kabel THE CABLE CONNECTION catalogue www.boehm-kabel.de A partnership to your advantage Four reasons......to choose Kabel We can supply to final consumers if you express the wish. Fast and reliable supply

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information