NSW/ACT QLD VIC/TAS SA/WA/NT

Size: px
Start display at page:

Download "NSW/ACT QLD VIC/TAS SA/WA/NT"

Transcription

1

2 PRODUCT Contents RANGE Icons 0 Innovation Fan Type Fan Type Wall Hung Split Systems Variable Capacity Pages - Split Ducted Cycling Split Ducted Variable Capacity Split Ducted Tri-Capacity Package Units Cycling Pages - Pages - Pages - Add On Air Conditioning Pages 8- Pages 0- The ActronAir range of air conditioners provides a solution for most applications. On the following pages, you ll get a thorough overview of each model along with its capabilities. From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs. And when you choose the comfort of an ActronAir system, you have the latest, most innovative technology at your fingertips. 8 0 Durability Performance MULTI DIRECTIONAL AIR FLOW Variable Capacity Ability to vary the capacity of a compressor, allowing better temperature control and operating costs, whilst reducing energy consumption. Variable Fan Technology Adjusts the airflow based on the requirements of each zone Variable Air Volume Technology Delivers individual temperature zone control in up to 8 zones Louvre Grille External louvre grille protection for improved durability Coil Protection An external coil protection for improved durability and corrosion resistance Vertical Discharge Enables installation in confined space & minimises re-circulated air Multi-Directional Air Flow -way automatic multi-directional airflow for improved air circulation. Electrical Centrifugal Fan Centrifugal forward curved fan for optimum air movement ECM Fan Centrifugal forward curved fan that uses an EC (Electronic Commutated) motor for superior air movement control, improved energy efficiency and easier commissioning EC Plug Fan s Centrifugal backward curved fan that uses an EC (Electronic Commutated) motor for improved energy efficiency, faster commissioning and flexibility in air handing options Single Phase Electrical Supply 0V Power Supply with Neutral and Earth connections Three Phase Electrical Supply 00V Power Supply with Neutral and Earth connections Scroll Axial and radial compliant scroll compressor for improved performance and durability Digital Scroll Variable capacity compressor ranging from 0% to 00% for improved comfort control and energy efficiency Low Noise Axial Fan Low noise Axial Fan for quieter operation Wall Hung Split System Operating Range Ducted System Operating Range Designed to keep operating at temperatures of - C to 0 C Engineered using high efficiency heat exchangers and superior components to deliver an operating range of -0 to 0 C Engineered using high efficiency heat exchangers and superior components to deliver an operating range of -0 to C Package Units Tri-Capacity Controls Pages - Page FOLLOW ME SLEEP MODE Follow Me Follow Me function uses remote control as a secondary temperature sensor for improved temperature control. Sleep Mode Sleep Program automatically adjusts temperature for better comfort during sleep time. Turbo Turbo function delivers faster cooling or heating. Tri-capacity Scroll s Used in commercial air conditioners, allowing capacity stages (~%, % and 00% compressor capacity) for improved building load matching and efficiency Inverter Rotary Rotary compressor for reliable operation all year round. Accessories Page

3 PRODUCT Product RANGE Line Up Total Capacity kw.kw.kw kw kw kw kw kw 0kW kw kw 0kW 0kW kw kw 0kW 8kW kw Wall Hung Split System Variable Capacity With advanced DC Inverter compressor technology, the wall split system delivers improved energy efficiency and reduced running costs. Split Ducted Cycling The SRA range operates at 00% capacity to deliver maximum performance in all seasons. The SCA range is available in single stage (00% capacity) or two stage (0% & 00% capacity) operation for improved comfort, performance and reliability. Split Ducted Variable Capacity ESP Plus Incorporates digital variable capacity (0-00%) operation for improved temperature control and energy efficiency, along with Variable Fan Technology (VFT) to deliver further energy efficiency. Split Ducted Variable Capacity Split Ducted Tri-Capacity ESP Ultima Combines the energy efficiency of VFT with Variable Air Volume (VAV) technology for individual temperature control of up to 8 zones. This unique technology delivers capacity stages (~,, 00% capacity) for improved comfort, efficiency and performance. Designed with dial-up airflow features for ease of commissioning. Add On Air Conditioning Designed for use with gas ducted heating systems. Package Units Cycling Incorporating scroll compressor technology in single stage (00% capacity) or two stage (0 & 00% capacity) operation for improved comfort, performance and reliability. Package Units Tri-Capacity This unique technology delivers capacity stages (~,, 00% Capacity) for improved efficiency, performance and reliability. Designed with dial-up airflow features for ease of commissioning.

4 Wall Hung Split System Single Phase (.-.kw) SLEEP MODE FOLLOW ME MULTI DIRECTIONAL AIR FLOW ROTARY COMPRESSOR COIL PROTECTION Cooling: up to 0ºC DB Heating: down to -ºC DB protection and SWA models only. OUTDOOR MODEL SWA0C SWAC SWA8C SWAC SWA8C INDOOR MODEL SWA0E SWAE SWA8E SWAE SWA8E Nett (Rated) Capacity (kw) Cooling (min-max).0 (0.8-.0).0 (.0-.8).00 (.0-.0).0 (.0-.0).0 (.0-8.0) Heating (min-max).0 (.-.0).0 (.0-.0).0 (.0-.0).00 (.0-8.0) 8.0 (.0-.00) Cooling (min-max) 0. (0.-.) 0.8 (0.-.). (0.-.). (0.8-.). (.-.0) Heating (min-max) 0. (0.-.) 0.8 (0.-.8). (0.-.0). ( ).8 (.0-.80) EER Rated Cooling..... COP Rated Heating V / Ph + N / 0Hz Rated Load Amps Rated (min-max). (.-.).0 (.-.0). (.-.8).0 (.-.) 0.80 (.0-.) Full Load Amps Moisture Removal (L/hr) Wiring Method 0A Pin Plug A Pin Plug A Pin Plug Hard Wire Hard Wire (to ) (to ) (to ) (to ) (to ).mm Suggested Minimum Mains Cable Size.mm.mm.mm.mm (0A GPO) (A GPO) (A GPO) Suggested Minimum to Cable Size mm ( Core).mm ( Core).mm ( Core) mm ( Core) mm ( Core) IP IP IP IP IP IPX0 IPX0 IPX0 IPX0 IPX0 Type / No. per unit Rotary / Starting Method DC Inverter Starting Capacity Range Cooling -% 0-% 0-0% -0% 0-0% Heating -0% -% 0-0% -0% 0-0% Axial / Pole / Direct Drive x Centrifugal / Pole / Direct Drive x (PULSE) Centrifugal / Pole / Direct Drive x Maximum 8 Airflow Range (l/s) Nominal Minimum Depth Dimensions (mm) Height Width Depth 00 8 Dimensions (mm) Height Width Operating Range (ºC) Cooling 0 to 0 Heating - to 8 8 Sound Pressure Level (Hi/Mi/Lo) db(a) / 0 / 8 / / 8 / / 8 / / 0 / / Sound Pressure Level (dba) at m / / / 8 / 0 8 / (Low/High Fan) Sound Power Level (dba) 0 / / / 8 / 0 / 0 MEPS Certified Yes Yes Yes Yes Yes Charge Factory Charge - (g) Pre-Charge Length - (m) Additional Charge - (g/m) Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential (m) included in max length Unit Connections Unit Connections Units supplied prior to February 0 have Amp/SAA Plugs. 0- Please see Product Foot Notes on Page - OUTDOOR MODEL SWA0C SWAC SWA8C SWAC SWA8C INDOOR MODEL SWA0E SWAE SWA8E SWAE SWA8E Star Rating - Cooling Star Rating - Heating Remote Controller RG-A RG RG RG RG Follow Me Function Yes Yes Yes Yes Yes Sleep Program Yes Yes Yes Yes Yes Turbo Mode Yes Yes Yes Yes Yes Self Clean Function Yes Yes Yes Yes Yes Timer On/Off Yes Yes Yes Yes Yes Dehumidification Yes Yes Yes Yes Yes -way Automatic Multi-directional Airflow Vertical auto-swing (up/down) Horizontal auto-swing (left/right) Hydrophilic Aluminium Coil Protection Manual (/ ). (/ ). (/ ). (/8 ). (/8 ). (/8 ). (/ ). (/ ).88 (/8 ).88 (/8 ). (/ ). (/ ). (/ ). (/8 ). (/8 ). (/8 ). (/ ). (/ ).88 (/8 ).88 (/8 ). (/ ). (/ ). (/ ). (/8 ). (/8 ). (/8 ). (/ ). (/ ).88 (/8 ).88 (/8 ) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Options and Accessories Yes Yes Yes Yes Yes 0 0 Warranty Trading Authorisation No.: AU0 N08

5 Split Ducted Cycling Single Phase (-kw) Cooling: up to 0ºC DB Heating: down to -0ºC DB 000-hour salt spray exposure AS/NZS 0:00 commutated motor (except for SRE0C) rd party control OUTDOOR MODEL SRE0C SRAC SRAC SRAC INDOOR MODEL SRG0E SRGE SRGE SRGE Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling.... Heating.... EER Rated Cooling...8. COP Rated Heating V / Ph + N / 0Hz 0V / Ph + N / 0Hz Rated Load Amps / / Total. /.8 /.. /.8 /.. /. / 0.. /. /.0 Full Load Amps / / Total. /. /.. /. /..0 /. / /. /.0 Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Compliant Scroll / Starting Method Soft Starter No. Refrigeration Circuits/No. Capacity Stages (Capacity range) / (00% capacity) Axial x Axial / Pole External Rotor / Direct Drive x Single Deck Centrifugal / ECM Direct Twin Deck Centrifugal / ECM Direct Drive x Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow Nominal Airflow 0 8 Depth Dimensions (mm) Height Width Depth Dimensions (mm) Height 0 Width Sound Pressure Level (dba) (low/high fan) 0 / 0 / 0 / / Sound Power Level (dba) (low/high fan) / / / / MEPS Certified Yes Yes Yes Yes LM Wall Controller (8 Zone) Included Included Included Included LM Wall Controller (8 Zone) - Secondary Master Controller Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Home Automation ON / OFF Capability Yes Yes Yes Yes Manual Inputs Capable for Third Party Control Optional Optional Optional Optional Maximum Number of Zones Options & Accessories OUTDOOR MODEL SRE0C SRAC SRAC SRAC INDOOR MODEL SRG0E SRGE SRGE SRGE Two Piece Fan Coil Coil Section Model SRAA SRAA SRAA Fan Section Model SRGF SRGF SRGF Soft Start - Included Yes Yes Yes Yes Drain Kit (ADRKT) - Included Yes Yes Yes Yes Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Optional Drain Tray - Model CDT CDT0 CDT0 CDT Hanging Kits (AHKFC) Optional PLDP - /0 PLDP - /00 PLDP - /00 PLR - /0S PLR - /S PL8R - /S PL0R - /0S Way PLS - /S Way PLS - /0S PL8S - /S PLS - /S PL0S - /0S PLS - /0S Way PL8S - /S PL0S - /SPS B - rd Party Manual Input ( Unit) Optional Optional Optional Optional H - Horizontal Discharge Fan ( Unit) Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional V - Upright Fan Coil Vertical Discharge (Fan Coil Unit) Optional Optional Optional Optional Z - Soft Starter ( Unit) Factory Charge - (g) not pre-charged Charge Pre-Charge Length - (m) 0 Δ Additional Charge - (g/m) 0 Δ Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length (/8).0 (/8) Unit Unit Condensate Drain Connection - Size Safety Tray Connection - Size (Flange Connection).0 (/8) to be cut and in the field.0 (/8) cut swage end 0mm OD 0mm ID Supply Duct H x W - (mm) 0 x (no flange) 00 x Return Duct H x W - (mm) 0 x 0 0 x 00 0 x 00 Δ Refer to installation instruction for gas charge information. Warranty Trading Authorisation No.: AU0 N08

6 8 Split Ducted Cycling Three Phase (-kw) Cooling: up to 0ºC DB Heating: down to -0ºC DB 000-hour salt spray exposure AS/NZS 0:00 commutated motor (except SRA0 & SRA0) rd party control OUTDOOR MODEL SRAC SRAC SRAC SRA0C SRA0C SRA0C INDOOR MODEL SRGE SRGE SRGE SRG0E SRA0E SRA0E Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz 0V / Ph + N / 0Hz Rated Load Amps Full Load Amps / / Total / / Total. /. /. 8. /. /.. /. /.. /. /.0 8. /. /.8. /. /..0 /. /.. /. /.8. /. /..8 /. / 0.. /. / /. /. Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Compliant Scroll / Starting Method D.O.L. No. of refrigeration Circuits/No of capacity stages (Capacity range) / (00% capacity) Axial / Pole External Rotor / Direct Drive x Twin Deck Centrifugal / Twin Deck Centrifugal / ECM Direct Drive x Pole / Direct Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow 0 0 Nominal Airflow Depth Dimensions (mm) Height Width Depth 80 Dimensions (mm) Height 8 Width Sound Pressure Level (dba) (low/high fan) 0 / 0 / / / / / Sound Power Level (dba) (low/high fan) / / / / / / MEPS Certified Yes Yes Yes Yes Yes Yes LM Wall Controller (8 Zone) Included Included Included Included Included Included LM Wall Controller (8 Zone) - Secondary Master Controller Optional Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Yes Yes Yes Yes Yes Yes Manual Inputs Capable for Third Party Control Optional Optional Optional Optional Optional Optional Maximum Number of Zones Options & Accessories OUTDOOR MODEL SRAC SRAC SRAC SRA0C SRA0C SRA0C INDOOR MODEL SRGE SRGE SRGE SRG0E SRA0E SRA0E Two Piece Fan Coil Coil Section Model SRAA SRAA SRAA SRA0A SRA0A Fan Section Model SRGF SRGF SRGF SRG0F SRA0F Soft Start - Included Optional Optional Optional Optional Optional Optional Drain Kit (ADRKT) - Included Yes Yes Yes Yes No No Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Yes Yes Optional Drain Tray - Model CDT0 CDT0 CDT CDT CDT CDT Hanging Kit (AHKFC) Optional PLDP - /0 PLDP - /00 PLDP - /00 PLDS - /00 PLDT- /0 PLR - /S PL8R - /S PLR - /0S PL0R - /0S PLR - /S PLR - /S Way PL8S - /S PL0S - /0S PLS - /S PLS - /0S PLS - /S Way PL8S - /S PL0S - /0S PL0S - /SPS PLS - /S B - rd Party Manual Input ( Unit) Optional Optional Optional Optional - - D - Fault Detection ( Unit) Optional Optional H - Horizontal Discharge Fan ( Unit) Optional Optional Optional Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Optional V - Upright Fan Coil Vertical Discharge (Fan Coil Unit ) Optional Optional Optional Optional Optional Optional Z - Soft Starter ( Unit) Optional Optional Optional Optional Optional Optional Factory Charge - (g) Charge Pre-Charge Length - (m) 0 0 Additional Charge - (g/m) Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length Unit Unit.0 (/).0 (/).0 (/8) 0.0 ().0 ().0 (/).0 (/8) cut swage end cut swage end to fit.0 ( ).0 (/).0 () to be in field Condensate Drain Connection - Size 0mm OD 0mm ID mm ID Safety Tray Connection - Size 0mm ID mm ID Supply Duct H x W - (mm) 00 x 80 x 8 (Flange Connection) Return Duct H x W - (mm) 0 x 00 0 x 00 0 x 0 0 x 0 8. (-/8) ID to fit field pipe.0 (/8).0 () 0-0 Please see Product Foot Notes on Page - Warranty Trading Authorisation No.: AU0 N08

7 0 Split Ducted Cycling Three Phase (-kw) Cooling: up to 0ºC DB Heating: down to -0ºC DB - SCG series on two stage systems 000-hour salt spray exposure AS/NZS 0:00 party control OUTDOOR MODEL SCA0C SCA0C SCA00C SCA0C SCA00C INDOOR MODEL SCG0E SCA0E SCA00E SCA0E SCG00E Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz 0-0V / Ph + N / 0Hz Rated Load Amps / / Total. / 8. /.. /. /.. /. / 0.. /. /.. /0. /. Full Load Amps / / Total. /. / 0.. /. /..0 /. /.. /. /.. /. /. Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Scroll / Scroll / Starting Method D.O.L. D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) /(00%) /(0%, 00%) Axial / Pole External Rotor / Direct Drive x Twin Deck Twin Deck Centrifugal / Centrifugal / Twin Deck Centrifugal / Pole / Direct Drive x ECM Direct ECM Direct Drive Drive x x Maximum Airflow Range (l/s) Nominal Minimum 0 Maximum Airflow 8 0 Nominal Airflow Depth 8 Dimensions (mm) Height 0 Width 8 Depth 0 Dimensions (mm) Height Width Sound Pressure Level (dba) (low/high fan). /..8 /.8. /..8 /.8.0 /.0 Sound Power Level (dba) (low/high fan). /..8 / 8.8. /..8 / / 8.0 MEPS Certified Yes Yes Yes Yes Yes OUTDOOR MODEL SCA0C SCA0C SCA00C SCA0C SCA00C INDOOR MODEL SCG0E SCA0E SCA00E SCA0E SCG00E D - Fault Detection ( Unit) Optional Optional Optional Optional Optional H - Horizontal Discharge Fan (Upright Unit) Optional Optional Optional Optional Optional H - Horizontal Discharge Fan ( Unit) Optional Optional Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional V - Upright Fan Coil Vertical Discharge ( Unit) Optional Optional Optional Optional Optional Z - -Phase Soft Starter ( Unit) Optional Optional Optional Optional Optional Factory Charge - (g),00,800 x, x,00 x,80 Charge Pre-Charge Length - (m) Additional Charge - (g/m) 0 per stage 0 per stage 00 per stage Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length (/8). (/8).0 (/) 8. (-/8) 8. (-/8) Unit Unit Condensate Drain Connection - Size Safety Tray Connection - Size (Flange Connection) 0-0 Please see Product Foot Notes on Page -. (/8) 8. (-/8). (/8) 8. (-/8). (/8) 8. (-/8). (/8) 8. (-/8) mm ID mm ID cut-off swage cut-off swage.0 (/).0 (/).mm ID BSP Female Thread.mm ID BSP Socket Supply Duct H x W - (mm) 0 x 0 Return Duct H x W - (mm) x 00 0 x 0 x 00 0 x 0 x C- Wall Controller (BCA Compliant) Optional Optional Optional Optional Optional Secondary Master Controller No No No No No Remote Temperature Sensor Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Optional Optional Optional Optional Optional Manual Inputs Capable for Third Party Control Optional Optional Optional Optional Optional Maximum Number of Zones Trading Authorisation No.: AU0 N08

8 Split Ducted Variable Capacity ESP Plus (Single/Three Phase) split system improved energy efficiency and lower indoor noise 0 to 00% operation Cooling: up to 0ºC DB Heating: down to -0ºC DB withstand 000-hour salt spray exposure AS/NZS 0:00 controller included on/off control Single Phase Three Phase OUTDOOR MODEL SRDC SRDC SRDC SRDC SRD0C SRD0C INDOOR MODEL SRVE SRVE SRVE SRVE SRV0E SRV0E Total (Gross) Capacity (kw) Cooling Heating Cooling (min - max) Nett (Rated) Capacity (kw) (.-.) (.-.) (.8-8.) (.-.88) (.-.) (.0-.00) Heating (min - max) (.-.) (.8-.00) (.-8.) (.-.) (.8-0.) (.-.0) Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz 00V / Ph + N / 0Hz 0V / Ph + N / 0Hz Rated Load Amps / / Total. /. /.. /. /.8 0.8/. /. 8. /. /.8. /. /..0 /.0 / 8.0 Full Load Amps / / Total. /. /.. /. /.. /. /.. /. /../. /.. /. /. Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Digital Scroll / Starting Method Soft Starter D.O.L. No. of refrigeration Circuits/No of capacity stages (Capacity range) / Variable (0-00% capacity) Axial / Pole External Rotor / Direct Drive x Twin Deck Centrifugal / ECM Direct Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow Nominal Airflow Depth Dimensions (mm) Height Width Depth Dimensions (mm) Height 8 Width Sound Pressure Level (dba) (low/high fan) / 0 0 / / / / / Sound Power Level (dba) (low/high fan) / / / / / 0 / MEPS Certified Yes Yes Yes Yes Yes Yes LM-D Wall Controller (8 Zone) Included Included Included Included Included Included LM Wall Controller (8 Zone) - Secondary Master Controller Optional Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Yes Yes Yes Yes Yes Yes Maximum Number of Zones Options & Accessories Single Phase Three Phase OUTDOOR MODEL SRDC SRDC SRDC SRDC SRD0C SRD0C INDOOR MODEL SRVE SRVE SRVE SRVE SRV0E SRV0E Two Piece Fan Coil Coil Selection Model - - SRVA - SRV0A - Fan Selection Model - - SRVF - SRV0F - Soft Start - Included Yes Yes Yes Optional Optional Optional Drain Kit (ADRKT) - Included Yes Yes Yes Yes Yes No Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Yes Yes Optional Drain Tray - Model CDT0 CDT0 CDT CDT CDT CDT Hanging Kit (AHKFC) Optional - - PLDS - /00 - PLDS - /00 - PLR - /S PL8R - /S PLR - /0S PL8R - /S PLR - /0S PLR - /S PL0R - /0S PLR - /S PL0R - /0S PLR - /S Way Way PL8S - /S PL0S - /0S PLS - /S PLS - /0S PLS - /S PL8S - /S PL0S - /0S PL0S - /SPS PLS - /S H - Horizontal Discharge Fan ( Unit) Optional Optional Optional Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Optional V - Upright Fan Coil Vertical Discharge ( Unit ) Optional Optional Optional Optional Optional Optional Z - Soft Starter ( Unit) Optional Optional Optional Factory Charge - (g) Charge Pre-Charge Length - (m) 0 Additional Charge - (g/m) Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length Unit Unit.0 (/).0 (/) 0.0 ().0 (/) cut swage end cut swage end cut swage end to fit.0 ( ).0 (/).0 () Condensate Drain Connection - Size 0mm OD 0mm ID 0mm OD 0mm ID mm ID Safety Tray Connection - Size 0mm ID mm ID Supply Duct H x W - (mm) 00 x 80 x Return Duct H x W - (mm) 0 x 00 0 x 00 0 x 0 0 x 00 0 x 0 0 x Please see Product Foot Notes on Page - Warranty Trading Authorisation No.: AU0 N08

9 Split Ducted Variable Capacity ESP Ultima (Single/Three Phase) 8 0 of the award winning ESP Plus reverse cycle ducted split system technology to deliver individual temperature zone control 0 to 00% operation improved energy efficiency in each individual zone : Cooling: up to 0ºC DB Heating: down to -0ºC DB 000-hour salt spray exposure AS/NZS 0:00 on/off control Single Phase Three Phase OUTDOOR MODEL SRDC SRDC SRDC SRD0C SRD0C INDOOR MODEL SRME SRME SRME SRM0E SRM0E Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling (min - max). (.-.) 8. (.8-8.).88 (.-.88). (.-.).00 (.0-.00) Heating (min - max).00 (.8-.00) 8. (.-8.). (.-.) 0.0 (.8-0.0).0 (.-.0) Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz 00V / Ph + N / 0Hz 0V / Ph + N / 0Hz Rated Load Amps / / Total. /. / /. /. 8. /. /.8. /. /..0 /.0 / 8.0 Full Load Amps / / Total. /. /.. /. /.. /. /.. /. /.. /. /. Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Digital Scroll / Starting Method Soft Starter D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) /Variable (0-00% capacity) Axial / Pole External Rotor / Direct Drive x Twin Deck Centrifugal / ECM Direct Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow Nominal Airflow Depth Dimensions (mm) Height Width Depth Dimensions (mm) Height 8 Width Sound Pressure Level (dba) (low/high fan) 0 / / / / / Sound Power Level (dba) (low/high fan) / / / / 0 / MEPS Certified Yes Yes Yes Yes Yes LM-D Wall Controller (8 Zone) Included Included Included Included Included LM Wall Controller (8 Zone) - Secondary Master Controller Optional Optional Optional Optional Optional AM-ZC Zone Controller Optional Optional Optional Optional Optional AM-ZS Zone Sensor Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Yes Yes Yes Yes Yes Maximum Number of Zones Options & Accessories Single Phase Three Phase OUTDOOR MODEL SRDC SRDC SRDC SRD0C SRD0C INDOOR MODEL SRME SRME SRME SRM0E SRM0E Soft Start - Included Yes Yes Optional Optional Optional Drain Kit (ADRKT) - Included Yes Yes Yes Yes No Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Yes Optional Drain Tray - Model CDT0 CDT CDT CDT CDT Hanging Kit (AHKFC) Optional PL8R - /S PLR - /0S PL8R - /S PLR - /0S PL0R - /0S PLR - /S PL0R - /0S PLR - /S PLR - /S Way PL8S - /S PL0S - /0S PLS - /S PLS - /0S PLS - /S Way PL8S - /S PL0S - /0S PL0S - /SPS PLS - /S H - Horizontal Discharge Fan ( Unit) Optional Optional Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Z - Soft Starter ( Unit) Optional Optional Optional Factory Charge - (g) Charge Pre-Charge Length - (m) 0 Additional Charge - (g/m) Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length (/).0 (/) 0.0 () Unit Unit cut swage end cut end cut swage end.0 (/) to fit.0 ( ).0 (/).0 () Condensate Drain Connection - Size 0mm OD 0mm ID 0mm OD 0mm ID 0mm ID mm ID Safety Tray Connection - Size 0mm ID mm ID Supply Duct H x W - (mm) 00 x 80 x Return Duct H x W - (mm) 0 x 00 0 x 0 0 x 00 0 x 0 0 x Please see Product Foot Notes on Page - Warranty Trading Authorisation No.: AU0 N08

10 Split Ducted Tri-Capacity Three Phase (-kw) (~%, % or 00% capacity) energy efficiency accurate commissioning withstand 000-hour salt spray exposure AS/NZS 0:00 - Unit OUTDOOR MODEL CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY00T-Q CAY00T-Q INDOOR MODEL EVY0T-Q ELY0T-Q EVY0T-Q ELY0T-Q EVY0T-Q ELY0T-Q EVY00T-Q ELY00T-Q Std Profile Low Profile Std Profile Low Profile Std Profile Low Profile Std Profile Low Profile Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz V / Ph + N / 0Hz Rated Load Amps / / Total. /. / 8.0. /. /. 8. /. /.0 8. /. / 0.. /. /.. /. / /. /. 0. /. /.8 Full Load Amps / / Total. /.8 / 0.. /. / /.8 / /. /.. /. /.8. /. /..8 /. /..8 /. /.0 Circuit Breaker Amps (Suggested) IP IP0 Type / No. per Unit Compliant Scroll / Starting Method D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) / Tri-Capacity (~% % 00%) Axial Low Noise / Pole External Rotor / Direct Drive x Variable Speed ECM Motor Direct Drive Backward Curve Plug Fan x (EVY Models), (ELY Models) Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow 0 Nominal Airflow Depth Dimensions (mm) Height Width 0 0 Depth Dimensions (mm) Height Width Sound Pressure Level (dba ) (low/high fan) 8 / / Sound Power Level (dba) (low/high fan) / 80 / 8 MEPS Certified Yes Yes Yes Yes Yes Yes BCA Table J.c Compliant C- Wall Controller (BCA Compliant) Optional Optional Optional Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Optional Optional Optional Commercial Control Interface - Third Party Controls Adjustable Dial-Up Airflow Adaptive Demand Defrost Options & Accessories OUTDOOR MODEL CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY0T-Q CAY00T-Q CAY00T-Q INDOOR MODEL EVY0T-Q ELY0T-Q EVY0T-Q ELY0T-Q EVY0T-Q ELY0T-Q EVY00T-Q ELY00T-Q Std Profile Low Profile Std Profile Low Profile Std Profile Low Profile Std Profile Low Profile Low Ambient / High Static Fans Optional Optional Optional Optional Optional Optional Optional Optional Drain Kit (ADRKT) - Included No No No No No No No No Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Yes Yes Yes Yes D - Fault Detection ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional K- Additional Full Coil Coat Protection ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional L- Additional Full Coil Coat Protection ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional P- IP Rated ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) U - Low Ambient +0C Optional Optional Optional Optional Optional Optional Optional Optional W - Three-Phase Sequence Protection Relay ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional X - IP Rated ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional Y - Powder Coating ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional Z - -Phase Soft Starter ( Unit Only) Optional Optional Optional Optional Optional Optional Optional Optional Factory Charge - (g) 00 & 0,00 00 &,00 00 &,00 00 &,00 Charge Pre-Charge Length - (m) (Crt # & Crt #) Additional Charge - (g/m) 0 & 0 & 00 & 00 & Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length 0 &.0 (/8) &.0 (/8).0 (/) &.0 (/8).0 (/) &.0 (/8) (Crt # & Crt #) & 8. (-/8) & 8. (-/8).0 () & 8. (-/8).0 () & 8. (-/8) Unit Connection &.0 (/8) &.0 (/8).0 (/) &.0 (/8).0 (/) &.0 (/8) (Crt # & Crt #) & 8. (-/8) & 8. (-/8).0 () & 8. (-/8).0 () & 8. (-/8) Unit Connection &.0 (/8) &.0 (/8).0 (/) &.0 (/8).0 (/) &.0 (/8) (Crt # & Crt #) & 8. (-/8) & 8. (-/8).0 () & 8. (-/8).0 () & 8. (-/8) Condensate Drain Connection - (Size /Type). mm ( ) Ø/BSP Female Thread Safety Tray Connection - Size/Type. mm ( ) Ø/BSP Socket Air Handing F - Front Discharge (EVY & ELY Models Only) T - Top Discharge (CAY Models Only) T- Top Discharge (EVY Models Only) Optional Optional Optional Optional Optional Optional Optional Optional Supply Duct H x W - (mm) 80 x 0 80 x x 0 80 x x 0 80 x x 0 80 x 000 Return Duct H x W - (mm) 0 x 0 x x 0 x x x x x Please see Product Foot Notes on Page - Trading Authorisation No.: AU0 N08

11 8 Add On Air Conditioning heating systems to remove heat and humidity Cooling: up to 0ºC DB 000-hour salt spray exposure AS/NZS 0:00 Single Phase Three Phase OUTDOOR MODEL SRAC SRAC SRAC SRAC SRAC SRAC SRA0C SRA0C INDOOR MODEL SRAA SRAA SRAA SRAA SRAA SRAA SRA0A SRA0A 0 Nominal Capacity (kw) Cooling Nominal Cooling Nominal EER Cooling Nett (Rated) Capacity (kw) Cooling Nett (Rated) Cooling Nett (Rated) EER Rated (AS/ NZS8..) Cooling V / Ph + N / 0Hz 00V / Ph + N / 0Hz Unit Rated Amps Unit Full Load Amps Circuit Breaker Amps (Suggested) Unit IP Type / No. per Unit Compliant Scroll / Starting Method Soft Starter D.O.L. No. of refrigeration Circuits/No of capacity stages (Capacity range) / (00% capacity) Axial / Pole External Rotor / Direct Drive x Maximum Airflow Range (l/s) Nominal Minimum Coil Static Pressure Drop Maximum Airflow 0 / 88 0 / 0 / 8 0 / 88 0 / 0 / 8 / 0 / Wet Coil / Dry Coil (Pa) at: Nominal Airflow 8 / 0 8 / / 8 8 / 0 8 / / 8 0 / 8 0 / Depth Dimensions (mm) Height Width Depth Dimensions (mm) Height 8 Width Sound Pressure Level (dba) (low/high fan) 0 / 0 / / 0 / 0 / / / / Sound Power Level (dba) (low/high fan) / / / / / / / / MEPS Certified Yes Yes Yes Yes Yes Yes Yes Yes Home Automation ON / OFF Capability Yes Yes Yes Yes Yes Yes Yes Yes Manual Inputs Capable for Third Party Control Yes Yes Yes Yes Yes Yes Yes Yes Options & Accessories Single Phase Three Phase OUTDOOR MODEL SRAC SRAC SRAC SRAC SRAC SRAC SRA0C SRA0C INDOOR MODEL SRAA SRAA SRAA SRAA SRAA SRAA SRA0A SRA0A Soft Start - Included Yes Yes Yes Optional Optional Optional Optional Optional Drain Kit (ADRKT) - Included Yes Yes Yes Yes Yes Yes Yes No Unit Integral Fan Coil Safety Tray - Included Yes Yes Yes Yes Yes Yes Yes Yes Optional Drain Tray - Model CDT0 CDT0 CDT CDT0 CDT0 CDT CDT CDT Hanging Kit (AHKFC) Optional PLDP-/0 PLDP-/0 PLDP-/00 PLDP-/00 PLDP-/00 PLDP-/00 PLDS-/00 PLDT-/0 - Way PL8S-/0S n/a n/a - Way - Way PL8S - /S n/a n/a PL0S - /0S n/a n/a PLS - /0S n/a n/a PL8S - /S n/a n/a PL0S - /SPS n/a n/a D - Fault Detection ( Unit) N / A N / A N / A Optional Optional Optional Optional Optional H - Horizontal Discharge Fan ( Unit) Optional Optional Optional Optional Optional Optional Optional Optional K- Coil Protection ( Unit) Optional Optional Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Optional Optional Optional Z - Soft Starter ( Unit) Optional Optional Optional Optional Optional Factory Charge - (g) Charge Pre-Charge Length - (m) 0 Additional Charge - (g/m) Maximum Field Pipe Length Range - (m) Maximum Vertical Height Differential - (m) included in max length Unit Unit.0 (/).0 (/) () (/8) (/8).0 (/) cut swage end cut swage end to fit. ( ).0 (/).0 () to be in field Condensate Drain Connection - Size 0mm OD 0mm ID mm ID Safety Tray Connection - Size 0mm ID mm ID Supply Duct H x W - (mm) 00 x 80 x 8 (Opening only, no flange) Return Duct H x W - (mm) 0 x 00 0 x 00 0 x 00 0 x 00 0 x 0 0 x Please see Product Foot Notes on Page - Warranty Trading Authorisation No.: AU0 N08

12 0 Package Unit Cycling Three Phase (-0kW) Package Model - Under/Over Configuration PCGU PCGU PCG0U PCA0U PCA0U PCG0U PCA0U PCA00U PCA0U PCG00U Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz Rated Load Amps Full Load Amps Circuit Breaker Amps (Suggested) IP Type / No. per Unit Compliant Scroll / Compliant Scroll / Starting Method D.O.L. D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) / (00% capacity) / (0%, 00% capacity) Axial / Pole External Rotor / Direct Drive x Twin Deck Twin Deck Centrifugal Centrifugal Twin Deck Centrifugal / Twin Deck Centrifugal / Twin Deck Centrifugal / Pole / ECM / ECM ECM Direct Drive x Pole / Direct Drive x / Direct Drive x Direct Direct Drive x Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow Nominal Airflow Depth 8 0 Unit Dimensions (mm) Height 00 0 Width Sound Pressure Level (dba) (low/high fan).0 /.0.0 /.0.0 /.0.0 /.0.0 /.0. / /.8. / /.8.0 /.0 Sound Power Level (dba) (low/high fan) 8.0 / /.0.0 /.0.0 /.0.0 /.0. /..8 /.8. /..8 /.8.0 / 8.0 MEPS Certified Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes C- Wall Controller (BCA Compliant) Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Manual Inputs Capable for Third Party Control Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Secondary Master Controller No No No No No No No No No No Maximum Number of Zones D - Fault Detection Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional H - Horizontal Discharge Fan Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional K- Coil Protection (Fan Coil & Unit) Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional W - Phase Sequence Protection Relay Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Z - Soft Starter Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Installation Information Factory Charge - (g) ,0,0 x x 0 x.mm ID BSP Female Condensate Drain Connection - Size 0mm OD mm ID Thread and.mm ID BSP Socket Supply Duct H x W - (mm) 00 x 00 x x 0 Return Duct H x W - (mm) 0 x 00 0 x 0 00 x 00 0 x 0 x 0 0 x 0 x 0 x operation Cooling: up to 0ºC DB Heating: down to -0ºC DB - PCG series cooling on two stage systems Package Model - Side By Side Configuration withstand 000-hour salt spray exposure AS/NZS 0:00 rd party control PCG0L/R PCG0L/R PCG00L/R PCG0L/R PCG00L/R Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz Rated Amps..... Full Load Amps Circuit Breaker Amps (Suggested) IP Type / No. per Unit Compliant Scroll / Compliant Scroll / Starting Method D.O.L. D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) / (00% capacity) / (0%, 00% capacity) Axial / Pole External Rotor / Direct Drive x Single Deck Centrifugal / ECM Direct Drive x Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow 0 Nominal Airflow 8 8 Depth 0 Unit Dimensions (mm) Height 0 Width Sound Pressure Level (dba) (low/high fan). / /.8. / /.8.0 /.0 Sound Power Level (dba) (low/high fan). /..8 /.8. /..8 /.8.0 / 8.0 MEPS Certified Yes Yes Yes Yes Yes C- Wall Controller (BCA Compliant) Optional Optional Optional Optional Optional Home Automation ON / OFF Capability Optional Optional Optional Optional Optional Manual Inputs Capable for Third Party Control Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Secondary Master Controller No No No No No Maximum Number of Zones D - Fault Detection Optional Optional Optional Optional Optional H - Horizontal Discharge Fan Optional Optional Optional Optional Optional K- Coil Protection ( Coil) Optional Optional Optional Optional Optional P- Coil Protection ( Coil) Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional W - Phase Sequence Protection Relay Optional Optional Optional Optional Optional Z - Soft Starter Optional Optional Optional Optional Optional Installation Information Factory Charge - (g) 0,,00 x x 000 x.mm ID BSP Female Condensate Drain Connection - Size mm ID ( Drain per unit) Thread and.mm ID BSP Socket Supply Duct H x W - (mm) 80 x x 00 Return Duct H x W - (mm) 80 x 0 80 x x 0 80 x x Please see Product Foot Notes on Page Please see Product Foot Notes on Page - Trading Authorisation No.: AU0 N08

13 Package Unit Tri-Capacity Three Phase (-kw) (~%, % or 00% capacity) energy efficiency accurate commissioning configurations 000-hour salt spray exposure AS/NZS 0:00 - Unit PACKAGE MODEL PKY0T-Q PKY0T-Q PKY0T-Q PKY00T-Q PKY80T-Q PKY0T-Q Total (Gross) Capacity (kw) Cooling Heating Nett (Rated) Capacity (kw) Cooling Heating Cooling Heating EER Rated Cooling COP Rated Heating V / Ph + N / 0Hz Rated Load Amps / / Total Full Load Amps (AS/ NZS8..) / / Total Circuit Breaker Amps (Suggested) IP Type / No. per Unit Compliant Scroll / (0-00 Models), (80-0 Models) Starting Method D.O.L. No. Refrigeration Circuits/No. Capacity Stages (Capacity range) (0-00 Models), (80-0 Models) / Tri-Capacity (~% % 00%) All Models Axial Low Noise / Pole External Rotor / Direct Drive x Variable Speed ECM Direct Drive Backward Curve Plug Fan x (Q Models), (Q Models) Maximum Airflow Range (l/s) Nominal Minimum Maximum Airflow Nominal Airflow Depth 0 0 Unit Dimensions (mm) Height Width Sound Pressure Level (dba) (low/high fan) / 0 / / Sound Power Level (dba) (low/high fan) / 8 / 8 8 / 8 MEPS Certified Yes Yes Yes BCA Compliant BCA Compliant BCA Compliant PACKAGE MODEL PKY0T-Q PKY0T-Q PKY0T-Q PKY00T-Q PKY80T-Q PKY0T-Q D - Fault Detection Optional Optional Optional Optional Optional Optional E- Economy Starter Kit Optional Optional Optional Optional Optional Optional G- Auto Outside Air Kit Optional Optional Optional Optional Optional Optional H- Manual Outside Air Kit Optional Optional Optional Optional Optional Optional K- Additional Full Coil Coat Protection ( Coil) Optional Optional Optional Optional Optional Optional L- Additional Full Coil Coat Protection ( Coil) Optional Optional Optional Optional Optional Optional R - 8 Demand Response Capability (AS.) Optional Optional Optional Optional Optional Optional U- Low Ambient +0ºC Optional Optional Optional Optional Optional Optional W - Three-Phase Sequence Protection Relay Optional Optional Optional Optional Optional Optional X- IP Rated Optional Optional Optional Optional Optional Optional Z - -Phase Soft Starter ( Unit Only) Optional Optional Optional Optional Optional Optional 0-8 Please see Product Foot Notes on Page - Air Handing Options Handing Top Supply Top Return Side Return Side Return Top Return Reverse Handing Top Supply C- Wall Controller (BCA Compliant) Optional Optional Optional Optional Optional Optional Remote Temperature Sensor Optional Optional Optional Optional Optional Optional Commercial Control Interface - Third Party Controls Adjustable Dial-Up Airflow Adaptive Demand Defrost Blue Hydrophylic Coil Fin Protection - Coil Louvred Coil Guard Side Supply Front Supply () Down Return Front Return () Front Return () Down Return Front Supply () Side Supply () Field Information Factory Charge -(g) For Q Models - (Crt # & Crt #), For Q Models (each ) 00 & &, &, &,800 8,00 (each),000 (each) Condensate Drain Connection Section. mm ( ) Ø BSP Female Thread.8 mm (-/ ) Ø BSP Female Thread - Size/Type Section. mm ( ) Ø BSP Socket.8 mm (-/ ) Ø BSP Socket Supply Duct H x W - (mm) 0 x x 00 Return Duct H x W - (mm) 00 x x 00 Down Supply Down Supply Trading Authorisation No.: AU0 N08

14 LIVING MASTER BED LIVING MASTER BED LIVING MASTER BED PROGRAM EXIT FAMILY BEDROOMS PROGRAM EXIT FAMILY BEDROOMS PROGRAM EXIT FAMILY BEDROOMS TIMER REPEAT KITCHEN NURSERY TIMER REPEAT KITCHEN NURSERY TIMER REPEAT KITCHEN NURSERY SELECT RUMPUS GUEST SELECT RUMPUS GUEST SELECT RUMPUS GUEST PRODUCT Controls RANGE & Sensors Accessories Controller Model LM hr ON/OFF timer day ON/OFF timer Auto Heat/Cool Modes Auto/ Continuous Fan Fan Setting ESP Mode Max. No. of Zones capability On Board Sensor Mimic Logic Filter Light Indicator Last Zone Enable/ Disable Zone Cards (V) Zone Cards (0V) LM Return Air Plenums Supply Air Plenums Model Number Size Model Number Size LM-D C- AM-ZC AM-ZS AERSN * PLR-/0S x 00mm ( ) PLR-/S x 0mm ( ) PL8R-/S x 0mm ( ) PLR-/0S x 00mm ( ) PLR-/S x 0mm (8 ) PL0R-/0S x 00mm ( ) PLR-/S x 0mm (8 ) Duct Plates Model Number Size PLDP-/0 x 0mm ( ) PLDP-/00 x 00mm ( ) PLDS-/00 x 00mm ( ) PLDT-/0 x 0mm (8 ) V Zone Barrels Hanging Kit ready for hanging kit Way Way Plain Way Plain Condensor Drain Tray from surrounding areas (e.g. concrete/tiles/pavers) from SRE0C SRA0C only Cables & Joiners PL8S-/0S x 00mm (") PLS-/S x 0mm (") PLS-/0S x 00mm ( ) PLS-/S x 0mm (") PL8S-/S x 0mm (") PL0S-/0S x 00mm (") PLS-/S x 0mm (8 ) PLS-/0S x 00mm ( ) PL8S-/S x 0mm ( ) PL0S-/SPS x( ) + x( ) PLS-/S x 0mm ( ) PL0S-/0S x 00mm ( ) PLS-/S x 0mm (8 ) and 0m length. be used with ActronAir Zone Barrels to ensure system optimum operation and to ensure warranty remains valid. to maintain integrity and to ensure faults or warranty issues do not occur. Foot Notes 0. Nominal Capacity = Unit kw rating excluding indoor fan kw (Add-On Cooling model only). Nominal Input Power = Input Power of the system less Fan Power (Add-On Cooling model only). Nominal EER = Nominal Capacity Nominal Input Power (Add-On Cooling model only).. Based on unit rating excluding indoor fan kw.. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).. Recommended circuit breaker size. This should be used as a guide only. Refer to AS/NZS 000 Australian/New Zealand Wiring Rules for more details.. Refer to Catalogue Unit Weight Distribution Guide section for details of weight points.. Sound Pressure Level at m distance is determined as the measured sound pressure at m perpendicular to the coil side of the condenser.. Determination of Sound Power Levels of Noise Sources, AS. - Precision Methods for Broad-Band Sources in Reverberation Rooms. 8. When Demand Response capability is chosen, the air conditioner will fully comply with AS. in the following modes: DRM,,.. Supplied as with -Phase soft starter. 0. For short pipe run of 0-0m or average -storey residential dwellings,.0mm (/ ) Gas Field Pipe and.mm (/8 ) Liquid Line may be used in place of the recommended.mm (/8 ) gas pipe and. (/ ) liquid line. Please refer to Capacity Selection Data & see Pipe Length Correction Multiplier for the drop in refrigeration capacity as a consequence of change in Gas Field Pipe diameter. Swaged end of and Units gas pipe to be cut in the field to fit ID into.0mm (/ ) replacement Field Pipe. Swaged end to be cut-off in the field to fit into field pipe. Important Notes: The Local Electricity Supply Authority may require limits on - starting current, running current and voltage drop, please check prior to purchase. When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values. Specifications subject to change without notice. Rated Conditions: Cooling: C DB / Air Entering C DB, C WB Heating: C DB, C WB / Air Entering 0 C DB Wall Hung Split System OperatingRange: Cooling: C DB to 0 C DB / Air Entering C DB Heating: -0 C DB to C DB / Air Entering C DB Ducted System Operating Range: Cooling: C DB to 0 C DB / Air Entering C DB Heating: -0 C DB to C DB / Air Entering C DB Warranty: For full terms and conditions of ActronAir warranty, please refer to warranty terms document -

15 Copyright 0 Actron Engineering Pty Limited ABN Registered Trade Marks of Actron Engineering Pty Limited. Actron Engineering Pty Limited.has applied for the registration of the Trade Mark ESP Ultima / NSW/ACT ActronAir Head Office Irvine Place Bella Vista NSW Ph: (0) Trade, Sales and Technical Support Enquiries 00 QLD ActronAir Benjamin Place Portlink Industrial Park Lytton QLD 8 Ph: (0) 8 0 Service and Warranty Enquiries 800 General Enquiries 00 VIC/TAS ActronAir Hallmarc Office Park Unit / Ricketts Road Mt Waverley VIC Ph: (0) 0 SA/WA/NT ActronAir Unit A/ Sir Donald Bradman Drive Hilton SA 0 Ph: (08) 8 8

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs. PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.

More information

NSW/ACT QLD VIC/TAS SA/NT

NSW/ACT QLD VIC/TAS SA/NT PRODUCT Contents RANGE Icons Fan Type Fan Type Ability to vary the capacity of a compressor, allowing better temperature control and operating costs, whilst reducing energy consumption. Centrifugal Fan

More information

PRODUCT RANGE. Trade, Sales and Technical Support Enquiries Service and Warranty Enquiries

PRODUCT RANGE.  Trade, Sales and Technical Support Enquiries Service and Warranty Enquiries Copyright 0 Actron Engineering Pty Limited ABN 00 6 0. Registered Trade Marks of Actron Engineering Pty Limited. Actron Engineering Pty Limited has applied for the registration of the Trade Marks Hercules,

More information

The ActronAir range of air conditioners provides a solution for most applications.

The ActronAir range of air conditioners provides a solution for most applications. Contents Icons Fan Type Fan Type Ability to vary the capacity of a compressor, allowing better temperature control and operating costs, whilst reducing energy consumption. Centrifugal Fan Centrifugal forward

More information

Commercial TRI-CAPACITY Performance and efficiencies through smart engineering. That s better. That s Actron.

Commercial TRI-CAPACITY Performance and efficiencies through smart engineering. That s better. That s Actron. Commercial Performance and efficiencies through smart engineering. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair

More information

VARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.

VARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls. Commercial Premium performance, flexible controls. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. Advanced performance with flexible options. The year 1984

More information

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Louvred Outdoor Coil Guard Pre-charged with

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

TRI-CAPACITY PACKAGE UNIT

TRI-CAPACITY PACKAGE UNIT TECHNICAL SELECTION TRI-CAPACITY PACKAGE UNIT +50 o C -10 o C 3 THREE PHASE TRI-CAPACITY EC PLUG FAN LOUVRE LOW NOISE FAN UNIT FEATURES Compliant Scroll Compressors Tri-Capacity 33% 67% 100% Capacity Stages

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

Air Cooled Packaged Units

Air Cooled Packaged Units Air Cooled Packaged Units Technical Data OPA 465, OPA 550, OPA 705, OPA 855, OPA 960 (ECO) Cooling Capacity 44.9kW - 96.0kW Heating Capacity 41.1kW - 90.0kW Contents OPA 465 960 ECO 3 General 3 Applications

More information

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw DRAFT Ducted Three Phase Packaged Air Conditioners Technical Data 96 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil OPTION TZT-71 Controller & Digital Scroll Compressor for close

More information

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160) FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioning 100% outside air About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

PREMIUM INVERTER DUCTED AIR CONDITIONING

PREMIUM INVERTER DUCTED AIR CONDITIONING PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs

More information

Ducted Split System Air Conditioners

Ducted Split System Air Conditioners Technical Data ISD 116, ISD 141, ISD 164, ISD 184, ISD 194, ISD 224 Cooling Capacity 11.4kW - 22.4kW Heating Capacity 10.8kW - 21.6kW Contents ISD 116 224 KYX SERIES 3 General 3 Applications 4 Air Flow

More information

Air Cooled Packaged Units Technical Data

Air Cooled Packaged Units Technical Data Technical Data OPA 2100 Eco Ultra Cooling Capacity 15kW - 200kW Heating Capacity 15kW -186kW Version 7 Contents OPA 2100 ECO ULTRA 3 General 3 Applications 4 Features 4 Energy Efficient Refrigerant R410A

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Air-conditioning. split ducted systems

Air-conditioning. split ducted systems Air-conditioning split ducted systems 1300 306 125 www.sygnal.com.au Dual Inverter *high static, variable refrigerant flow, variable indoor airflow SYSTEM MODEL HS-IV-10 HS-IV-14 HS-IV-17 INDOOR UNIT MODEL

More information

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM 1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain

More information

Ducted Split System Air Conditioners

Ducted Split System Air Conditioners Technical Data ISD 380, 465, 570, 670, 840, 950 Cooling Capacity 37.6kW - 94.9kW Heating Capacity 35.9kW - 90.1kW Contents ISD 380 950 General 3 Applications 4 Air Flow Selection 4 Features Refrigerant

More information

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS Ducted Split System Air Conditioners Technical Data ISDL Series Optional HAN-L6 Controller Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 2.9 kw 1. kw JANUARY 5 ISDL SERIES DUCTED SPLIT

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz] R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge

More information

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 2-8 GENERAL DATA 2.3. INVERTER SERIES 2.3.1. INVERTER (RAS-25YHA2/35YHA3/50YHA2/60YHA2/70YHA2/80YHA2) Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2 Power Supply From Outdoor Unit

More information

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

DC INVERTER DUCTED AIR CONDITIONERS

DC INVERTER DUCTED AIR CONDITIONERS DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s EC Motor MultiZone Fan Coil Units IXDL-Y Series 00 000 l/s Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

P5RF Series Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans. Cooling Capacity: 6,4 97,4 next dx C rcgroupairconditioning R410 E C UP FLOW DOWN FLOW MIN FETURES

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it Hi-Wall Inverter Split System Cooling and heating, exactly where and when you need it Save on Running Costs 2.6kW & 3.2kW 4.2kW & 5.0kW 7.0kW & 8.0kW High Efficiency Along with running cost savings due

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Ducted medium static pressure monosplit DC Inverter

Ducted medium static pressure monosplit DC Inverter +VAV (Variable Air Volume) Ducted medium static pressure monosplit Unique solutions 20 19 22 For 18-24-30-36 23 24 18 A ++ RC08W 2016 Ducted medium static pressure monosplit FUNCTIONS > Ducted line available

More information

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

FORM NO. PTZ-806 REV. 1 HEAT PUMPS FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Q4SE Series Single Packaged Heat Pump, Single Phase

Q4SE Series Single Packaged Heat Pump, Single Phase TM TECHNICAL SPECIFICATIONS Q4SE Series Single Packaged Heat Pump, Single Phase Q4SE-14 SEER 2-5 Ton Units Cooling: 23,600 to 56,500 Btuh Heating: 22,200 to 55,500 Btuh The Q4SE Series single packaged

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP VEP075N432K Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Hinged electrical box for ease of maintenance

More information

Multizone Multi Split systems

Multizone Multi Split systems 19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

DC INVERTER VRF SYSTEMS C-VRF

DC INVERTER VRF SYSTEMS C-VRF DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it Hi-Wall Inverter Split System Efficient, effective and comfortable cooling and heating where you need it The Convenient Solution Feature Packed The Brivis Hi-Wall Inverter Split System has a pleasing,

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw) -P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air

More information

SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz M-SERIES SUBMITTAL DATA: MXZ-2C20NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: Outdoor Unit: MXZ-2C20NAHZ ACCESSORIES 3/8" x 1/2" Port Adapter (MAC-A454JP; for use with

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw Flex Series Modular Air-cooled Chillers and Heat Pumps Cooling Capacity 38-329 kw Heating Capacity 47-354 kw 1 Trane Flex Series Modular air/water chillers and heat pumps units with axial fans and scroll

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant

More information

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Fan Coil Units. Technical Data ECDEN FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF Fan Coil Units Technical Data ECDEN10-400 FWL-DT/DF TABLE OF CONTENTS FWL-DT/DF 1 Features.............................................................

More information

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw Chiller VLC 524 to 1204 Air Cooled Condensing Units Engineering Data Manual 154 to 347 kw Outstanding Strength Points Units with R410A refrigerant (it will be the real replacement of R22). As near azeotropic

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A

More information

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SE Series M1200 Product Line Single Packaged Heat Pump 14 SEER - 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information