Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Size: px
Start display at page:

Download "Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401"

Transcription

1 February 26, 1976 Supersedes PL dated October 15,1974 Pages 1-8 Prices effective April 29, 1974 Subject to change without notice Selling Policy Mailed to E, D, C/1991, 2430/ PL Standard Bill of Material/ Design Features Amp cutouts include tin plated parallel groove connectors suitable for copper or aluminum conductors from No. 8 to 4/0 ACSR. 200 Amp cutouts and 300 Amp disconnects include eyebolt connectors suitable for copper or aluminum conductors from No. 6 to 250 MCM. Fuse holders for 14.4/24.9 and 1 shot 27Kv cutouts are identical in length. All cutouts are furnished with NEMA "B" crossarm mounting brackets. All castings are molded from aluminum bronze ingots, except the disconnect blades which are molded from manganese bronze. All Westinghouse fuse holders will accommodate either solid or expendable caps. Voltage Rating Single Voltage Cutouts with single voltage ratings are suitable for application on circuits with lineto-line voltages not in excess of value shown. Dual Voltage The use of LOX cutouts is verified by extensive tests conducted on all voltages from 34.5 kv multi-grounded wye down to 2.4 kv delta. These cutouts are suitable for application on single phase circuits having maximum line-to-ground voltage not in excess of value shown to the left of diagonal line. For three phase circuits, the maximum lineto-line voltage should not exceed the value shown to the right of the diagonal line. Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana /24.9, 27 and 20/34.5 Kv and 200 Amps Interrupting Capacity Up to Amps Amp heavy duty cutouts have paper tubes impregnated with a phenolic resin. Tubes are centerless ground and painted ASA-70 grey. Amp extra heavy duty cutouts and all 200 Amp cutouts have glass filament wound tubes with an epoxy resin binder. Tubes are centerless ground and are not painted. 200 Amp cutout can be converted to a 300 Amp disconnect by interchanging the fuse holder and the appropriate length disconnect blade from the Parts Section of this Price List. Interrupting Rating Interrupting ratings for Westinghouse LOX cutouts are established on the basis of the maximum line-to-ground voltage across the fuse tube. The voltages used in establishing the ratings are as follows: Cutout Voltage Rating 14.4/ 24.9 KV 20/34.5 KV 27 KV Voltage Across Fuse Tube to Establish Interrupting Rating 20 KV 27 KV P WEA Page 1 Non-Load break Open Fuse Cutouts Type LOX

2 Page 2 Single Cutout List Prices, Standard Styles: Order by Style Number on Tops or Q-09CD Description Cont. NEMA BIL Style Style List Wt. Lbs. Cutouts Current Interrupting Number Number Price With Brkt. Per Rating Rating RMS '73 Design '74 Design Net Ship- Pallet Asym. Amps ping 14.4/24.9 KV Grounded Wye Maximum Voltage Heavy Duty (Solid Cap) A696A01 236C909A A693A01 236C909A Extra Heavy Duty (Solid Cap) A697A01 236C909A Extra A6A01 236C909A Normal Duty (Solid Cap) A698A01 236C909A A699A01 236C909A Disconnect A701A01 236C909A /34.5 KV Grounded Wye Maximum Voltage Heavy Duty (Solid Cap) A313A01 236C909A A314A01 236C909A KV Maximum Voltage A988A01 236C909A Extra A092A01 236C909A (j) For 7.8/13.8 and cutouts refer to high as 27 KV. Where recovery voltage does not ex- PWEA. ceed, which is usually the case on three phase One shot rating. Fuse holder has to be replaced after installations and all single phase installations, the cut amp operation. Designed for application on 25 out has a 5-shot rating of Amps asymmetrical. KV grounded wye systems where faults on three phase equipment installations may see recovery voltages as Cutout-Arrester Combination List Prices: Order by Style Number on TOPS Style No. Style No. Cont. Type Interrupting Cutout Arrester List Approx. Cutouts '73 Design '74 Design Amps of Amps Description Rating Price WI. Lbs. Per Mtg. Exp. Cap. Net Ship- Pallet 14.4/24.9 Kv Grounded Wye Maximum Voltage 633A324A01 236C912A08 Crossarm 8,000 Heavy Duty A323A01 236C912A07 Pole 8,000 Heavy Duty ping

3 Parts Fuse Holders and Disconnect Blades for LOX Cutouts Order by Style Number on 0-09 Only Description Continuous NEMA For LDX Cutout; Current Interrupting Style Number of Rating Rating Rms Fuse Holder or Amperes Asymmetrical Disconnect Blade Amperes For 7.8/13.8 Kv Cutouts Heavy Duty (Solid Cap) A342A A343A01 Extra Heavy Duty (Solid Cap) A344A01 Extra A345A01 Normal Duty (Solid Cap) A347A A348A01 Disconnect A239G01 For 15 Kv Cutouts Heavy Duty (Solid Cap) A497A A498A01 Extra Heavy Duty (Solid Cap) C083G05 Extra C083G07 Normal Duty (Solid Cap) C694G C694G08 Disconnect A239G02 For 14.4/24.9 Kv Cutouts Heavy Duty (Solid Cap) A499A A500A01 Extra Heavy Duty (Solid Cap) A523G17 Extra A523G19 Normal Duty (Solid Cap) A523G A523G28 Disconnect A239G02 For 20/34.5 Kv Cutouts Heavy Duty (Solid Cap) A316A A317A01 For 27 Kv Cutouts A091A01 Extra Heavy Duty (Solid Cap) A093A01 Spare Caps for Fuseholders Description Style Number RAM AD of Each Cap For Amp Cutouts Solid Cap for All Amp LDX 162A775H Expendable Cap for All Amp LDX Heavy Duty 3872A21G For 200 Amp Cutouts Solid Cap for All 200 Amp LDX 162A775H Expendable Cap for 200 Amp LDX Heavy Duty 161A292H RAM AD List Price $ list Price of Each Cap $ P WEA Page 3

4 Page 4 Optional Features/Accessories The standard styles can be modified in a variety of ways. To price a cutout other than a standard style, select the base price from Modi- Accessory fication Number A B c D E List Price Adders (+) or Deducts (-) 200 Amp main contacts on Amp cutouts. NOTE: Amp cutouts are normally furnished with a main contact capable of carrying Amps continuous with a fuseholder or 200 Amps with a disconnect blade. + $0.90 Delete the NEMA "A" (366C723G05) or "B" ( 403A 101 G03) bracket. Furnish NEMA "B" braeket (403A101G03) in place of NEMA "A" bracket (366C723G05). (Do not deduct for NEMA "A") - $ $0.75 Eyebolt connectors to accommodate No.6 to 250 MCM copper or aluminum conductors in place of the parallel groove connectors 5554A16H01 on Amp cutouts that accommodate lli 8 solid to 4/0 ACSR. Two required per cutout. (628A333H01) + $1.00 Ea. Connector Furnish parallel groove connector 5554A 16H01 that accommodates lli 8 solid to 4/0 ACSR on 200A cutouts in place of standard eyebolt that accommodates No. 6 to 250 MCM (628A333H01). Two required per cutout. - $1.00 Ea. Connector the standard style table on the basis of the cutout voltage, current, and interrupting rating and then add or subtract the modification price additions or deductions to the base price to determine the total list price. Standard Configuration Once the cutout bill of material and list price have been determined, a style number must be assigned for order entry. This style number is available from the Distribution Apparatus Division, Bloomington, Indiana. Modification Configuration

5 Optional Features/Accessories for Standard Units and Combination Units, Continued Modi- Accessory List Price Standard fica- Adders ( +) Configuration tion or Number Deducts(-) F G H J Eyebolt connectors to accommodate No. 8 to 2/0 copper or aluminum conductors in place of the parallel groove connectors on Amp cutouts. Two required per cutout. (678A517G01) Special hookeye to increase the opening force by a factor of approximately 3. (803B200H01) Oversize crossarm mounting bracket for crossarms up to 6-1 /8"' in height and 4-1 /2" in width. Standard NEMA bracket is for 3" x 4" to 4" x 5" crossarms. (366C926G05) + $0.80 Ea. Connector + $ $0.10 6" Carriage bolts 161 A486H21 for NEMA brackets in place of the standard 5" carriage bolts 161 A487 H01 furnished as part of the standard style. Cork gasket mounting cushion under the nut on the top contact bolt and the back bracket bolt. + $0.30 For Two Bolts + $0.10 Ea. Gasket P WEA Page 5 Modification Configuration

6 Page 6 Optional Features/Accessories for Standard Units and Combination Units, Continued Modi- Accessory List Price Standard fica- Adders ( +) Configuration tion or Number Deducts ( -) K L M 1 /2" x 1-1/2" bolt assembled into the cutout mounting bracket, including lock washer and star washer. NOTE: This carriage bolt is normally pressed into the "L" bracket of the NEMA mounting bracket. When the bolt is to be assembled by the user into the mounting bracket, a deduct should be made for the bracket per modification " B" if it is not required. + $0.35 Hooks for use with the S & C loadbuster tool. + $0.90 Seacoast design. All galvanized steel parts on the cutout are replaced either by stainless steel or silicon bronze parts. This includes the top contact terminal support and stop, the top contact and mounting bracket bolts, the bottom clamp, and the bottom clamping bolts as indicated by arrows. + $6.75 Modification Configuration

7 I Optional Features/Accessories for Standard Units and Combination Units, Continued Modi- Accessory List Price Standard fica- Adders ( +) Configuration tion Number or Deducts (-) N 0 p Elongated "L" bracket 367C802H13 with an "A" dimension of 5". NOTE: Standard "'L" bracket 366C723H01 has an "A" dimension of 2-1/4". Universal mounting bracket on combination units to provide either pole or crossarm mounting. + $ $1.50 Bracket for mounting two (2) arresters on either type of combination mounting bracket: NOTE: Adder for arrester also required. + $1.65 r-- I A=2.q " P WEA Page 7 Modification Configuration Solder less Connectors on Top and Bottom Terminals for Number 6 Solid to Number 2 Stranded Cable

8 P WEA Page 8 Optional Features/Accessories for Standard Units and Combination Units, Continued Modification Number Q R s Accessory To furnish the following arrester on a combination unit in place of a 10 KV arrester: 3 KV 6 KV 12 KV To furnish second arrester on a combination unit for dual mounting: 3 KV 6 KV 9/10 KV 12 KV 18 KV To furnish a 200 Amp cutout on a combination unit in place of a Amp cutout. Further Information Description: DB LBU, DB LOX, D WE A. NCX Fuse Links Section Enclosed Fuse Cutouts Current Limiting Cutouts PL Load break Cutouts PL Non-Loadbreak Cutouts P WE A Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana List Price Adders ( +) or Deducts (-) $ $ $7.50

9 8 October 15, 1974 Supersedes PL dated April 29, 1974 Pages 1-2 and PL , dated April 4, 1974, pages 1-2 Prices effective April 29, 1974 Subject to change without notice Selling Policy Mailed to E, D, C/1991 /PL Standard Bill of Material/ Design Features Amp cutouts include tin plated parallel groove connectors suitable for copper or aluminum conductors from No. 8 to 4/0 ACSR. 200 Amp cutouts and 300 Amp disconnects include eyebolt connectors suitable for copper or aluminum conductors from No. 6 to 250 MCM. Fuse holders for 15Kv and 14.4/24.9 and 1 shot 27Kv cutouts are identical in length. The only difference in the cutouts is the BIL of the cutouts which is determined by the diameter of the porcelain. Amp 7.8/13.8Kv and 15Kv cutouts have NEMA "A" brackets. All other cutouts are furnished with N EMA "B" crossarm mounting brackets. Voltage Rating Single Voltage Cutouts with single voltage ratings are suitable for application on circuits with lineto-line voltages not in excess of value shown. Dual Voltage The use of LOX cutouts is verified by extensive tests conducted on all voltages from 34.5 kv multi-grounded wye down to 2.4 kv delta. These cutouts are suitable for application on single phase circuits having maximum line-to-ground voltage not in excess of value shown to the left of diagonal line. For three phase circuits, the maximum lineto-line voltage should not exceed the value shown to the right of the diagonal line. Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana /13.8, 15 and 14.4/24.9, 20/34.5 Kv 50, and 200 Amps Interrupting Capacity Up to Amps All castings are molded from aluminum bronze ingots, except the disconnect blades which are molded from manganese bronze. All Westinghouse fuse holders will accommodate either solid or expendable caps. Amp heavy duty cutouts have paper tubes impregnated with a phenolic resin. Tubes are centerless ground and painted ASA-70 grey. Amp extra heavy duty cutouts and all 200 Amp cutouts have glass filament wound tubes with an epoxy resin binder. Tubes are centerless ground and are not painted. 200 Amp cutout can be converted to a 300 Amp disconnect by interchanging the fuse holder and the appropriate length disconnect blade from the Parts Section of this Price List. Interrupting Rating Interrupting ratings for Westinghouse LOX cutouts are established on the basis of the maximum line-to-ground voltage across the fuse tube. The voltages used in establishing the ratings are as follows: Cutout Voltage Rating 7.8/13.8 KV 14.4/24.9 KV 20/34.5 KV 27 KV Voltage Across Fuse Tube to Establish Interrupting Rating 7.8 KV 20 KV 27 KV P WEA Page 1 Non-Load break Open Fuse Cutouts Type LOX

10 P WEA Page 8 Optional Features/Accessories for Standard Units and Combination Units, Continued Modification Number Accessory List Price Adders ( +) or Deducts ( -) s To furnish the following arrester on a combination unit in place of a 10 KV arrester: 3 KV 6 KV KV T u To furnish second arrester on a combination unit for dual mounting: 3 KV 6 KV 9/10 KV 12 KV 18 KV To furnish a 200 Amp cutout on a combination unit in place of a Amp cutout. Further Information Description: DB LBU, DB LDX Fuse Links Section Enclosed Fuse Cutouts Current Limiting Cutouts PL Loadbreak Cutouts PL We tin? house Electric Dlstnb tjon Corporation Apparatus Division Bloommgton, Indiana $ $ $

11 Westinghouse Dual Voltage The use of LOX cutouts is verified by extensive tests conducted on all voltages from 34.5 kv multi-grounded wye down to 2.4 kv delta. These cutouts are suitable for application on single phase circuits having maximum line-to-ground voltage not in excess of value shown to the left of diagonal line. For three phase circuits, the maximum line-to-line voltage should not exceed the value shown to the right of the diagonal line. Single Voltage Cutouts having single voltage ratings are suitable for application on circuits with lineto-line voltages not in excess of value shown. Prices effective August 24, 1970; subject to change without notice. Discount Symbol CC-53 Selling Policy Non- Loadbreal< Open Fuse Cutouts Type LOX PL Page 1 7.8/13.8, 15 and 14.4/ /34.5 Kv 50, and 200 Amps Interrupting Capacity Up to Amps List Prices, Single Insulator: Order by Style Number on TOPSal Standard Type LOX (Dropout) Description Conlin- NEMA uous Int. Rat- Current ing Rms Rating Asym. Amperes Amperes 7.8/13.8 Kv Grounded Wye Maximum Voltage Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) 00 Extra Normal Duty (Solid Cap) Disconnect Kv Maximum Voltage Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) 8000 Extra Normal Duty (Solid Cap) Disconnect /24.9 Kv Grounded Wye Maximum Voltage Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) 8000 Extra Normal Duty (Solid Cap) Disconnect /34.5 Kv Grounded Wye Maximum Voltage Heavy Duty (Solid Cap) Kv Sky Gray List Wt. Lbs. BIL Style Price with Brkt. NumberCD<n Net Ship ping 633A326A01 $ A327A A328A A329A A331A A332A A333A A473A A474A A475A A476A A478A A479A A480A A696A A693A A697A A6A A698A A699A A701A A313A01 I A314A CD ampere LOX style numbers include tin-plated parallel groove type terminals suitable for copper or aluminum conductors from No. 8 solid to 4/0 ACSR. 200 ampere cutouts include eyebolt terminals suilable for conductors No. 6 to 250 MCM. en Style numbers and prices do not include Fuse Links. See for rating 14.4/24.9 Kv and 20/34.5 Kv units are packed 18 per pallet. All others are 24 units per pallet. March 9, 1972 Supersedes PL , pages 1-2, dated August 24, 1970 E, D, C/1991 /PL

12 u. Yl...,.,, PL Page 2 Non-Loadbreak Open Fuse Cutouts Type LOX 7.8/13.8, 15 and 14.4/24.9, 20/34.5 Kv 50, and 200 Amps Interrupting Capacity Up to Amps Fuseholders and Disconnect Blades for LBU and LDX Cutouts Order by Style Number on TOPS Description For 7.8/13.8 Kv Cutouts Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) Extra Heavy Duty ( Exp. Cap) Normal Duty (Solid Cap) Disconnect Continuous Current Rating Amperes For 15 Kv Cutouts ( Amp Cutouts Only) Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) Extra For 15 Kv Cutouts (200 Amp Cutouts Only) Normal Duty_ (Solid Cap) Disconnect For 14.4/24.9 Kv Cutouts ( Amp Cutouts Only) Heavy Duty (Solid Cap) Extra Heavy Duty (Solid Cap) Extra For 14.4/24.9 Kv Cutouts (200 Amp Cutouts Only) Normal Duty (Solid Cap) Disconnect For 20/34.5 Kv Cutouts Heavy Duty (Solid Cap) Spare Caps for Fuseholders NEMA Interrupting Rating Rms Asymmetrical Amperes For LDX Cutout Style Number for Fuse Holder 633A342A01 633A343A01 633A344A01 633A345A01 633A347A01 633A348A01 680A239G01 633A497A01 633A498A01 367C083G05 367C083G C694G07 367C694G08 680A239G02 633A499A01 633A500A01 678A523G17 678A523G A523G27 678A523G28 680A239G02 633A316A01 633A317A01 List Price $ Description Style Number List Price of Each Cap of Each Cap For Amp Cutouts Solid Cap for All Amp LDX Expendable Cap for All Amp LOX Heavy Duty For 200 Amp Cutouts Solid Cap for All 200 Amp LOX Expendable Cap for 200 Amp LOX Heavy Duty Further Information Description: DB LBU, DB LOX Fuse Links Section Enclosed Fuse Cutouts A775H02 161A292H01 162A775H03 161A292H03 Westinghouse Electric Corporation Distribution Apparatus Division, Bloomington, Indiana Printed in USA $ """"'

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv) Outdoor Distribution (4.16 through 25 ) Specifications Conditions of Sale STANDAD: Seller s standard conditions of sale set forth in Price Sheet 153 apply, except as modified under WAANTY QUALIFICATIONS

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

Type ICX Outdoor open type cutout

Type ICX Outdoor open type cutout Distribution cutouts Type IC Outdoor open type cutout Product features 7.8 kv, 15 kv, 15/27 kv, 27 kv, or 38 kv on 100 A 7.8 kv, 15 kv, and 15/27 kv only on 200 A 110, 125, 150, 170, or 180 kv BIL 180

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB Type ICX Interchangeable Cutout 15-38 kv Outdoor Distribution Cutout Product Bulletin 1VAG271201-DB Product Features 15, 27, or 38 kv 110, 125, 150, 180, or 200 kv BIL 100 A, 200 A Fused 300 A Disconnect

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013 10AA Type C-Polymer Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all

More information

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv) Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015 10A Type C PORCELAIN Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10A Page 1 Type C Cutouts LINKBREAK cutout, pages 8-10 LOADBREAK cutout with Arc-Chute interrupter,

More information

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

T YPE MZ DISTRIBUTION S TANDARD CUTOUT T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7 The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015 10AA Type C-POLYMER Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations Catalog 10AA Page 10AA-1 Quality Construction Efficient Current Transfer The Type C-Polymer cutout has an all

More information

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order S&C Alduti-Rupter Switchesa Indoor Distribution ( kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 0 apply. SPECIAL TO THIS PRODUCT:

More information

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS

More information

S&C Recloser Bypass Disconnects

S&C Recloser Bypass Disconnects S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers

More information

WLI Medium Voltage Switchgear Renewal Parts

WLI Medium Voltage Switchgear Renewal Parts Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement

More information

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets Surge Arresters Surge Arrester/Type L use ombination Electrical Apparatus 235-26 escription ooper Power Systems surge arrester/type L interchangeable fuse cutout combinations are available in a wide variety

More information

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1 t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear

More information

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in

More information

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526 Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526 Section 10A 10A-1 Warranty - Material Hubbell Power Systems, Inc. warrants all products sold

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Catalog 14B January 2015 HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch.

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.

More information

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection

More information

K-Limiter high ampere Companion II fuse

K-Limiter high ampere Companion II fuse Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently

More information

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv) S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching

More information

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information

T HREE-SHOT TYPE MZR F USE CUTOUT

T HREE-SHOT TYPE MZR F USE CUTOUT T HREE-SHOT TYPE MZR F USE CUTOUT Page 1 of 7 D ESCRIPTION It is known that about 90% of the defects that occur in an air distribution system, are of a transient origin, i.e., are transient faults which

More information

S&C Loadbuster Disconnects

S&C Loadbuster Disconnects S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for

More information

Catalog 14A January 2013

Catalog 14A January 2013 Catalog 14A January 2013 Page 1 January 2013 Type AR (Automation-Ready) Switch 14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt Description The Hubbell unitized Type AR switch is a distribution-level,

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN Fusing Equipment MN132010EN Effective February 2016 Supersedes S240-64A-1 October 1998 COOPER POWER K-Limiter back-up current-limiting fuse installation instructions SERIES DISCLAIMER OF WARRANTIES AND

More information

Jumpers & Load Pickup Tools

Jumpers & Load Pickup Tools Jumpers & Load Pickup Tools Catalog 2300 May 2016 Jumpers & Load Pickup Tools 2300 May 2016 Page 2301 All Chance Insulated Jumpers meet ASTM F 2321 Standard Specification. G4758 15kV 5 5 / 8 " G4765 25kV

More information

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBITIONS Warranty - Material Chance warrants all products sold by it to be merchantable (as such term is defined in the Uniform Coercial

More information

S&C Type XS Fuse Cutouts

S&C Type XS Fuse Cutouts S&C Type XS Fuse Cutouts Outdoor Distribution (4.16 kv through 25 kv) S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection Descriptive Bulletin 351-30 August 25, 2003 Supersedes

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Electronic Resettable Sectionalizer

Electronic Resettable Sectionalizer POWER SYSTEMS, INC. Protected by U.S. Patents No. 5,612,661; 4,935,715; DES. 278,331 and other patents pending Warranty - Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable

More information

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below Instructions for Cast Resin Bushing, 15 KV & Below Fig. 1 Cast Resin Bushing The Westinghouse Cast Resin Bushing, used for voltages 15KV and below, is made by casting an insulating resin around the conductor.

More information

SPECIFICATION BULLETIN

SPECIFICATION BULLETIN SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:

More information

S&C Type XS Fuse Cutouts

S&C Type XS Fuse Cutouts S&C Type XS Fuse Cutouts Outdoor Distribution 4.16 kv through 25 kv Application An Unexcelled Cutout S&C Type XS Fuse Cutouts, when fused with S&C Positrol Fuse Links provide full-fault-spectrum protection

More information

BRACKETS, MOUNTS & HARDWARE

BRACKETS, MOUNTS & HARDWARE HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

JUMPERS & SWITCHING TOOLS

JUMPERS & SWITCHING TOOLS INSULATED JUMPER SETS 368 INSULATED JUMPER SETS FOR 15 KV, 25KV AND 35 KV Used for bypassing work areas when upgrading lines and when making temporary or emergency repairs Continuous-current ratings for

More information

10DD 10DD-1. Section CAUTION:

10DD 10DD-1. Section CAUTION: POLYMER Electronic Resettable Sectionalizer Protected by U.S. Patents No. 6,593,842; 5,854,582; 5,612,661; 4,935,715; 4,795,996; and other patents pending Section 10DD-1 10DD Warranty - Material Hubbell

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana Supersedes Descriptive Bulletin, pages 1-8, dated January, 1976 Mailed to: E, D, C/38-000F Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

More information

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-10,000 feet KV May 975 Supersedes 8-2 F WE A, Pages -2, dated January 975 E, D, C/98 /DB Dimensions, Weights and Creep These notes apply to all ratings.. These arresters are designed for 0,000 feet. ncrease clearances

More information

RBA Catalog Numbers and Information

RBA Catalog Numbers and Information 50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926 Technical Guide Load-break, General Description The Drywell Current Limiting Fuse Cannister is a removable fuse assembly for use in single and three

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN Surge Arresters MN235004EN Effective December 2015 Supersedes S235-26-1 August 2012 COOPER POWER SERIES Surge arrester interchangeable fuse cutout combination installation instructions DISCLAIMER OF WARRANTIES

More information

TYPE BILT DISCONNECT SWITCHES

TYPE BILT DISCONNECT SWITCHES TYPE BILT DISCONNECT SWITCHES OUTDOOR HOOKSTICK OPERTED (DISTRIBUTION CLSS) For sectionalizing and tap applications 7.5KV through 38KV 900 -- 40,000 momentary Furnished with hooks for loadbreak tool Used

More information

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II

More information

Easy-On II Terminations

Easy-On II Terminations Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional

More information

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN Switches MN008004EN Effective April 2016 Supersedes S328-10-1 June 2013 COOPER POWER SERIES UltraSIL polymer-insulated D-73P disconnect switches installation instructions DISCLAIMER OF WARRANTIES AND LIMITATION

More information

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4 General Information: DT-100 DT-150 DV-100 DV-150 De-energized Switches TPL 44-816, July 1999, Page 1 of 4 Type DT-100 & DT - 150, Tap Changers; Type DV-100 & DV- 150, Dual Voltage Switches - General Information

More information

PRODUCT CATALOGUE. Overhead System

PRODUCT CATALOGUE. Overhead System PRODUCT CATALOGUE Overhead System Information Tel : 03-4777547 Fax : 03-4777570 E-mail : overseas@jaker.com.tw Web : www.jaker.com.tw Add : No.787, Xinwen Rd. Xinwu Dist., Taoyuan City 327, Taiwan Contents

More information

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc. DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw

More information

Specif ications. Minimum Surge Arrester Rating, kv

Specif ications. Minimum Surge Arrester Rating, kv &C Fault amer Fuse Limiter Outdoor Distribution ( kv through kv) For Overhead Pole-op ransformers pecif ications Conditions of ale ADAD: eller s standard conditions of sale set forth in Price heet 0 apply.

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION Fusing Equipment Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly Electrical Apparatus 240-40 GENERAL Cooper Power Systems Bay-O-Net Fuse Assemblies are used to protect transformers and distribution

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV December, 1975 New nformation and Supersedes DB 38-131 Pages 1-4, dated May 1972, and 38-121 D WE A, Pages 1-4, dated April1974 E, D, C/1981/ DB Westinghouse Electric Corporation Distribution Apparatus

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

www. ElectricalPartManuals. com r n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin Westinghouse Application Transpac power centers are for applications where space availability is critical and thus the power center must be put into special locations such as against the wall, in closets.

More information

3.0OVERHEAD TRANSMISSION SWITCHES

3.0OVERHEAD TRANSMISSION SWITCHES HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 3 Overhead Transmission Switches CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Unit Substation Transformers 5 and 15 KV Class

Unit Substation Transformers 5 and 15 KV Class Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical

More information

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard

More information

Steel Fabrications Equipment Brackets

Steel Fabrications Equipment Brackets April 2004 Page 25 of 43 H. R. Steel; Each bracket includes (2) 1/2 x 1 hex bolts, flat washers, and special retaining clips as well as (1) 1/2 x 2 captive carriage bolt, shake proof washer, lockwasher,

More information

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12 Bulletin DB-104E12 Type RL-C Side Break Switch 7.2-69 kv 600-2000 A. CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Type RL-C

More information

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17 GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT

More information

Blocks and Holders. In-Line Watertight Fuseholders. Applications. Benefits. Features. Specifications. w w w. l i t t e l f u s e.

Blocks and Holders. In-Line Watertight Fuseholders. Applications. Benefits. Features. Specifications. w w w. l i t t e l f u s e. Littelfuse 600 volt in-line watertight fuse holders are the ideal answer for all high humidity and corrosive environments where fuses are required. Available in both breakaway and non-breakaway, single

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN Fusing Equipment MN132011EN Effective January 2016 Supersedes KS1.1-01-1 May 2003 HX-CB loadbreak fuse cutout installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

More information

OVERHEAD DISTRIBUTION SWITCHES

OVERHEAD DISTRIBUTION SWITCHES OVERHEAD DISTRIBUTION SWITCHES 0800 442 182 www.transnet.co.nz CONTENTS LineBOSS 15kV - 35kV Sidebreak GOAB Switch - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 LineBOSS Selection

More information

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors Loadbreak/Deadbreak Connectors CA650079EN Supersedes 650-10 December 2005 COOPER POWER SERIES and 600 A, 15, 25, and 35 kv junction bars for General Eaton designs its Cooper Power series junction bars

More information

OVERHEAD DISTRIBUTION SWITCHES

OVERHEAD DISTRIBUTION SWITCHES HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 2 Overhead Distribution Switches CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton,

More information

UltraSIL polymer-housed VariSTAR station-class surge arresters

UltraSIL polymer-housed VariSTAR station-class surge arresters Surge s Catalog Data CA235013EN Supersedes August 2015 COOPER POWER SERIES UltraSIL polymer-housed VariSTAR station-class surge arresters General Eaton has set a new standard of excellence for polymer-housed

More information

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated

More information

Medium Voltage Outdoor Apparatus Portfolio 2009

Medium Voltage Outdoor Apparatus Portfolio 2009 PPMV, April/May 2009 Medium Voltage Outdoor Apparatus Portfolio 2009 May 5, 2009 Slide 1 Summary Reclosers Outdoor dead tank vacuum circuit breakers Outdoor live tank circuit breakers Pole mounted circuit

More information

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters Section 1-1 1 Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications

More information

TYPE V CENTER BREAK SWITCH

TYPE V CENTER BREAK SWITCH TYPE V CENTER BREAK SWITCH 3-PHASE, GROUP-OPERATED (SUBSTATION AND TRANSMISSION APPLICATIONS) *Available in Copper Horizontal upright, vertical or underhung mounting 15KV through 230KV 600A through 4000A

More information

Fuse/Var Technical Data

Fuse/Var Technical Data Fuse/Var Technical Data 38-852 CAPACITOR FUSES Selection Guide Interrupting Type ABB Voltage Rated Capability Discharge (Combination) Application See Type Rating Current Iind Icap Capability (Current Limiting)

More information

Fuse Blocks and Holders Fuse Block Technical Data Fuse Blocks 250 Volt E4 600 Volt E5 Cartridge Fuse Pullers Fuse Holders. ATC / Mini Fuse Tabs

Fuse Blocks and Holders Fuse Block Technical Data Fuse Blocks 250 Volt E4 600 Volt E5 Cartridge Fuse Pullers Fuse Holders. ATC / Mini Fuse Tabs BLOCKS AND HOLDERS 1850 Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: 416-741-7336 Fax: 416-741-9104 SECTION E BLOCKS AND HOLDERS E1 and Holders Fuse Block Technical Data E2-E3 250 Volt E4 600 Volt

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

NX indoor current-limiting fuses

NX indoor current-limiting fuses Fusing Equipment Catalog Data CA132049EN Supersedes 240-60 September 2009 COOPER POWER SERIES NX indoor current-limiting fuses General Eaton provides overload protection for all indoor and underground

More information