1 EX5. Technical Characteristics. Dimensions

Size: px
Start display at page:

Download "1 EX5. Technical Characteristics. Dimensions"

Transcription

1 These robust IP rated standalone keypads incorporate proximity access and are designed to operate in both internal and external environments. EX5P Keypads include backlit metallic or plastic keys with a choice of plastic or metal housings (surface or flush). They incorporate an easy to follow programming menu allowing up to 99 unique codes/fobs and the setting of relay output times. The units also include inputs to trigger the relay from a push to exit button. Both audible and visual indication is standard indicating that a code is correct or incorrect while also helping to navigate through the programming menu. Technical Characteristics Codes / Fobs: 99 User Codes (1-8 digits) & Fobs Read Range: 3-12cm Operating Modes: Single security access with either a Code or Fob Double security with Code + Fob or Fob + Fob Relays: 2 Relays - R1: 24v DC / 120v AC) R2: (2A/24V DC / 120v AC) Relay Time: 1-99 Seconds or latching (00) IP Rating IP65 Power: 12v AC/DC Current: Standby 20mA / Maximum 180mA Dimensions 90mm 105mm 43 52/72 120mm mm 40mm 1 EX5

2 Installation Instructions 43 ABS Housing Surface Cable Cable Ø6.0 Ø6.0 30mm 30mm (8 x 30 CSK) 2 (M3 x 6mm) security screw 52/ 72 Metal Housing Surface (8 x 30mm CSK) 2 (M3 x 6mm) 2 EX5

3 102 Metal Housing Flush Cable Ø6.0 30mm (8 x 30mm CSK) 4 (M3 x 6mm) Terminal Connections Master code reset jumper Terminals Tamper switch DG/PS/0009 IS-01 LED G LED R DG/PS/0009 IS-01 EX5P 12 AC/DC 12 AC/DC Voltage in PB1 Push to exit input 1 (Active GND) GND Push to exit ground PB2 Push to exit input 2 (Active GND) +LED G + Green LED -LED G - Green LED NC rmally closed Relay 1 C Common NO rmally open +LED R + Red LED -LED R - Red LED +9V CODIX DATA BUS GND Connections for CODIX peripherals TAMP TAMP Tamper switch output (rmally closed) NC rmally closed Relay 2 C Common NO rmally open 3 EX5

4 12v DC Wiring Diagram 12 DC PSU + - IN4002 NC C NO LED G Relay 2 BUS LED R - + GND + DATA - +9V TAMP PB2 TAMP GND NC PB1 C NO Relay 1 12V AC/DC PTE (rmally Open) 12v AC Wiring Diagram 12 AC PSU IN nF NC C NO LED G Relay 2 BUS LED R - + GND + DATA - +9V TAMP PB2 TAMP GND NC PB1 C NO Relay 1 12V AC/DC IN4002 PTE (rmally Open) 4 EX5

5 Adding a User Code or Fob Press 0 Enter <user number> (01-99) (Up to 99 codes may be added) Enter <new user code> (1-8 digits) and / or <present fob> Relay Time Enter <relay number> (1 or 2) Enter <relay time> (01-99) (Enter 00 if latch mode required) Press 3 + <user number> Enter <relay number> to be triggered [1=Relay 1] [2=Relay 2] [12=Relays 1 & 2] relays? codes / fobs? Delete All Codes & Fobs Press 8 Press 99 Delete a User Code or Fob Press 9 Enter <user number> (01-99) to delete codes / fobs? 5 EX5

6 Double Security The keypad as standard either accepts a user code or fob. The keypad may be programmed so that it requires a code entered and a fob presented, or 2 individual fobs be presented. This is done by adding both the code + fob, or fob1 + fob2 to the same memory location. Adding a User Code & Fob In this instance a user has to enter a code, followed by presenting his/her key fob. Adding Fobs 1 & 2 In this instance a user has to present fob1 to the reader, followed be fob 2. Press 0 Enter <user number> (01-99) (Up to 99 codes may be added) Press 0 Enter <user number> (01-99) (Up to 99 codes may be added) Enter <new user code> (1-8 digits) <present fob 1> <present fob> <present fob 2> Press 3 + <user number> Press 3 + <user number> Enter <relay number> to be triggered [1=Relay 1] [2=Relay 2] [12=Relays 1 & 2] Enter <relay number> to be triggered [1=Relay 1] [2=Relay 2] [12=Relays 1 & 2] codes / fobs? codes / fobs? 6 EX5

7 Resetting the Master Code (P 3) (P 3) (P 3) (P 3) A B Disconnect power and close jumper P3. Reconnect power. Beep Beep + Yellow LED blinks Remove jumper P3. Yellow LED switches on + Long beep Enter the default master code 000 Enter the new master code e.g 2578 followed by Beep Beep Press B and the yellow LED switches off Troubleshooting Keypad does not respond to key presses 1. Check the correct voltage is present on the input terminals (12 ac/dc). Keypad does not register key fob 1. Try another key fob. Regardless if key fob is programmed or not the reader should attempt to read the key fob. Keypad is not accepting default master code Perform master code reset. Keypad no longer accepts user code or fob(s) 1. Check master code has been changed from the default. 2. Check back EMF protection across lock release. Keypad accepts user code or fob(s) but no longer releases lock 1. Check the correct relay output is assigned to user code. 2. Check all push to exit buttons are normally open. 3. Check for continuity across relay contacts when user code is entered. 4. Check lock wiring for continuity. 5. Check the correct voltage is present on the input terminals (12/24v ac/dc). Red / Green LED not functioning 1. Check LR & LG wiring. 2. Check a diode is present if device is powered by 12v AC. Relay triggers and does not return back to its previous state 1. Check relay is not set up to latch. 7 EX5

8 rthern Office Videx Security Ltd Unit 4-7 Chillingham ind Est Newcastle Upon Tyne Ne6 2XX Tel: Fax: Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD Fax: Technical Support tech@videx-security.com Tel: Fax: EX5

USER GUIDE KAS-840-DEN KAS-850-RDEN

USER GUIDE KAS-840-DEN KAS-850-RDEN USER GUIDE KAS-840-DEN KAS-850-RDEN 1 Discover the etouch Remote Control Keyless Lock Thank you for purchasing KAS etouch Remote Control Keyless Lock. As you ll soon discover, this stylish electronic touch

More information

USER GUIDE KAS-840-DEN KAS-850-RDEN

USER GUIDE KAS-840-DEN KAS-850-RDEN USER GUIDE KAS-840-DEN KAS-850-RDEN 1 Discover the etouch Remote Control Keyless Lock Thank you for choosing KA Security s etouch Remote Control Keyless Lock. As you ll soon discover, this stylish electronic

More information

Transponder Immobilizer Genius GT-550

Transponder Immobilizer Genius GT-550 Transponder Immobilizer Genius GT-550 www.geniuscaralarm.com 9 Introduction Congratulations, on the purchase of our security system for your vehicle, Read through the operating system user manual the transponder

More information

ILISP610-A Shift Interlock Chevy/GMC Full Size Van Chevy/GMC Full Size Van L Contact InterMotive for specific applications

ILISP610-A Shift Interlock Chevy/GMC Full Size Van Chevy/GMC Full Size Van L Contact InterMotive for specific applications An ISO 9001:2008 Registered Company ILISP610-A Shift Interlock Chevy/GMC Full Size Van 2008-2018 Chevy/GMC Full Size Van 2008-2015 4.6L Contact InterMotive for specific applications Introduction The ILISP610-A

More information

SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS CR4 FOUR STATION CONTROL MODULE The CR4 module operates on 12V or 24V DC and provides control of four (4) stations. Each CR4 station accepts a Dry () trigger input and provides one (1) Fused 2 Amp SPDT

More information

AWZ 110. AWZ 13,8V/1A/7Ah/LM

AWZ 110. AWZ 13,8V/1A/7Ah/LM AWZ 110 v.1.3 AWZ 13,8V/1A/7Ah/LM Linear buffer power supply unit Grade 2. EN* Edition: 9 from 02.11.2017 Supercedes the edition: 8 from 23.01.2017 GREY POWER plus Features: EN50131-6 compliance, 1 2 grades

More information

Model K20 installation guide. ProSecurity

Model K20 installation guide. ProSecurity Model K20 installation guide ProSecurity NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional

More information

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual M u l t i P o w e r CM MultiPower Installation and Operating Manual Index 1. Introduction of the 4HS submersible pumps range... 3 2. Safety Instructions... 4 3. CM MP installation... 5 3.1 Electric wiring...

More information

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21 Table of Contents Product Overview 01 / 02 Introduction / Warnings 03 / 04 Battery Operation / Battery Maintenance 05 / 07 Battery Installation 05 Charging the Battery 06 Master Code Programming 08 Remote

More information

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO 30 OTTO DC2

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO 30 OTTO DC2 MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO 30 OTTO DC2 REMOTE CONTROL BASICS Wall Mount Holder Remove cover from base by prying with flat head screwdriver. Use supplied fasteners and anchors to attach

More information

for Autonomous Operation Quick User s Guide SOR SOR Quick User s Guide for Autonomous Operation Rev 1

for Autonomous Operation Quick User s Guide SOR SOR Quick User s Guide for Autonomous Operation Rev 1 Quick User s Guide for Autonomous Operation SOR SOR Quick User s Guide for Autonomous Operation 15-00079 Rev 1 1 The SOR Series Electronic Dosimeter Welcome! The SOR/R and its sister products (DMC 2000

More information

Rally computer 3 Rally computer 3.GPS *

Rally computer 3 Rally computer 3.GPS * Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to

More information

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC PSBSH 2012B v.1.2 PSBSH 13,8V/2A/7Ah/HERMETIC Buffer switch mode power supply unit, EN** Edition: 7 from 02.11.2017 Supercedes the edition: 6 from 08.06.2017 Features: DC 13,8V/2A uninterruptible power

More information

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO RECHARGE OTTO RECHARGE PLUS OTTO RECHARGE MAX

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO RECHARGE OTTO RECHARGE PLUS OTTO RECHARGE MAX MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO RECHARGE OTTO RECHARGE PLUS OTTO RECHARGE MAX REMOTE CONTROL BASICS Wall Mount Holder Remove cover from base by prying with flat head screwdriver. Use supplied

More information

Responder 350. Installation Guide

Responder 350. Installation Guide Responder 350 Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may

More information

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring www.zkteco.com Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring Diagram FR1200 Connection Weigand Connection

More information

Programmable Output Module Installation Manual

Programmable Output Module Installation Manual Programmable Output Module Installation Manual PROGRAMMING CODE: (4 digits) (default = 1818) To enter programming mode, press [ ENTER] + programming code ADDRESS 000: 1 / 8 ADDRESS 001: 1 / 8 HOW TO:

More information

Maximiser Progressive Controller

Maximiser Progressive Controller Maximiser Progressive Controller Street & Race Model Owner's Manual 44 (0) 01302 834343 www.noswizard.com Introduction Congratulations on purchasing the Maximiser for the ultimate in progressive nitrous

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry Multiplex System Multiplex System Installation & Instructions (UM15 ~ 22272-03) Table of Contents Introduction... 1 Standard e-fob Operation and Features...

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

CONTENTS. GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2

CONTENTS. GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2 CONTTS GERAL PRESTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2 PRODUCT DESCRIPTION 2 Product components 2 Area of application 2 POINTS TO CHECK PRIOR TO INSTALLATION 3 Preliminary checks

More information

TEL: G&C Electronics CC E. T.

TEL: G&C Electronics CC E. T. TEL: +27 21 448 6774 G&C Electronics CC FAX: +27 21 447 7794 E. T. CK 89/31531/23 E-mail : etsystems@icon.co.za Internet: www.et.co.za 15 Nelson Road P.O. Box 34524 Observatory Groote Schuur Cape Town

More information

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. KE 680 DELUE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD Installation And Operation Manual MEGATRONI CALIFORNIA, U.S.A. KE 680 1 INSTALLATION DIAGRAM H8: 10 Pin White Mini Connector H8 10

More information

SST-3 Start-Stop-Throttle

SST-3 Start-Stop-Throttle SST-3 Start-Stop-Throttle Installation & Operation Guide Revision 1.1 Internet: www.wiredrite.com E-mail: info@wiredrite.com Page 1 CONTENTS Introduction 2 Hardware Mounting 2 Connections 2 Operation &

More information

CONTROL UNIT OMEGA 800-R. User manual

CONTROL UNIT OMEGA 800-R. User manual CONTROL UNIT OMEGA 800-R User manual INDEX 1. DESCRIPTION AND MAIN FEATURES... 3 2. DISPLAY AND CONTROL BUTTONS... 4 3. INSTALLATION AND CONNECTIONS... 5 4. MENU STRUCTURE... 6 5. HOW TO CHECK OR MODIFY

More information

650XV Installation Guide

650XV Installation Guide 650XV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may result

More information

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index POWER SUPPLIES & TRANSFORMERS

More information

SIDE ROLL SENSOR TROUBLESHOOTING GUIDE

SIDE ROLL SENSOR TROUBLESHOOTING GUIDE SIDE ROLL SENSOR TROUBLESHOOTING GUIDE WARNING Service the roll sensor(s) only if you are an authorized technician. The roll sensor triggers airbags and seat restraints. Accidental deployment could cause

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM ENGINE IMMOBILISER ENGINE IMMOBILISER SYSTEM 1 ENGINE IMMOBILISER SYSTEM PRECAUTION NOTICE: When disconnecting the cable from the negative (-) battery terminal, initialize the following systems after the

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4 QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series Four Door TCP/IP Web Server Controller Model: ACP-DXEL Table of Contents 0- Introduction 0 - Overview 0. - Package Contents 0. - Installation Requirements

More information

3000W HF/PFC Battery Charger

3000W HF/PFC Battery Charger 3000W HF/PFC Battery Charger Description Advanced high frequency switching design with 92% typical efficiency Fully sealed enclosure providing improved reliability in demanding environments > 0.98 Power

More information

SmartFOAM. Electronic Foam Proportioning Systems. Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179

SmartFOAM. Electronic Foam Proportioning Systems. Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179 Electronic Foam Proportioning Systems Models: Class A only 1.7AHP, 2.1A Class A/B 3.3, 5.0, 6.5 FOAM OPERATION QUICKSTART FSG-MNL-00179 HALE PRODUCTS, INC / CLASS 1 607 NW 27th Avenue Ocala, FL 34475 U.S.A.

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

EMF-2 / EMF-2m Multi-Function Timer

EMF-2 / EMF-2m Multi-Function Timer 0 Timberlea Blvd., Mississauga, LW T Telephone: 0-- Fax: 0-- Toll-Free: --- Web: www.camdencontrols.com EMF- / EMF-m Multi-Function Timer Installation Instructions Ver. A-00 MADE IN ANADA PAGE OF Section

More information

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B) TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B) TECHNICAL MANUAL v1.3 JANUARY 2014 Technical Manual (Updated 6 th January 2014) No Vehicle timer Vehicle delay timer Overrun timer

More information

2005 Directed Electronics, Inc. Vista, CA N412V 01-05

2005 Directed Electronics, Inc. Vista, CA N412V 01-05 Model 211HV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may

More information

Model 2100 Installation Guide

Model 2100 Installation Guide Model 2100 Installation Guide 2001 Directed Electronics, Inc. Vista, CA N2100 4-01 Rev. N/C 1.1 table of contents What Is Included..................... 2 Wiring Quick Reference Guide............ 3 Primary

More information

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m V200 USER MANUAL SWING GATE OPENER 100kg 1.m 100kg 1.m Content Important Safety Advice... Content of the Kit... Connection Diagram... Installation Guide... Actuator... Control box... AC cable wiring...

More information

Model 2000 Installation Guide

Model 2000 Installation Guide Model 2000 Installation Guide 2001 Directed Electronics, Inc. Vista, CA N2000 8-01 Rev. N/C 1.0 table of contents What Is Included..................... 2 Primary Harness (H1), 12-Pin Connector..... 3 Door

More information

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual Orica Seismic Electronic Initiation System OSEIS TESTER Manual Version 2.00a, November 2006 Overview Oseis System... 2 1. Oseis Detonator, Tester and accessories... 3 1.1 Oseis electronic detonator...

More information

USERS GUIDE LO-21U LOCKOUT RELAY

USERS GUIDE LO-21U LOCKOUT RELAY USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

2005 Directed Electronics, Inc. Vista, CA N426V 07-05

2005 Directed Electronics, Inc. Vista, CA N426V 07-05 350HV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may result

More information

Series AV. Pushbutton Switches NUT O-RING HOW TO ORDER

Series AV. Pushbutton Switches NUT O-RING HOW TO ORDER Pushbutton Switches SPECIFICATIS: BUSHING: 22mm. CTACT RATING: 2A @ 48VDC or 125VAC. ELECTRICAL LIFE: 10,000cycles at full load. CTACT RESISTANCE: 10m-ohms max. initial @2-4VDC. INSULATI RESISTANCE: 1,000M-ohms

More information

Volkswagen Information System. Introduction

Volkswagen Information System. Introduction Volkswagen Information System Introduction In this section you ll find information about: Using the instrument cluster menus: Basic version Using the instrument cluster menus: Premium version with multi-function

More information

USER MANUAL LEVER LOCK DIGITAL TOUCHPAD TEMPLATE. 120x165(mm)

USER MANUAL LEVER LOCK DIGITAL TOUCHPAD TEMPLATE. 120x165(mm) 120x165(mm) Mark Ø1" (25.4mm) hole at center of door edge. 2" 1-3/4" 1-9/16" 1-3/8" 51 45 40 35 FOR ( ) 2-3/8 60mm BACKSET Fit here on door edge FOR ( ) 2-3/4 70mm BACKSET TEMPLATE Limited Warranty Statements

More information

(electronic Access & Security Keyless-entry)

(electronic Access & Security Keyless-entry) e-ask Systems (electronic Access & Security Keyless-entry) Entrance doors, compartment doors or baggage doors, RF transmitter FOB, keypad or both...now you can have it all. Keyless convenience and security

More information

ED900. Low energy operator. Customizing Features: Book 3 of 3

ED900. Low energy operator. Customizing Features: Book 3 of 3 Low energy operator Customizing Features: Book 3 of 3 2 TABLE OF CONTENT Contents Page 1. ettings / ervice 4-8 2. Diagnosis / Troubleshooting 9-10 3. Error messages 11-13 Customizing Features on Your Door

More information

M40/50RF System - Installers Guide

M40/50RF System - Installers Guide M40/50RF System - Installers Guide Contents Glossary... 3 M40/50RF Motor... 3 SUITE Remote... 3 Battery Installation... 3 Introduction... 4 1) Install the Shade... 4 2) Create the Hub Motor... 4 3) Join

More information

QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS

QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS Page 1 Table of Contents SECTION 1... 2 Setting up the Electronic Lock... 2 Adding & Deleting Users & Superviss... 3 Operating

More information

VEHICLE CONTROLS Walk Away Auto Lock*

VEHICLE CONTROLS Walk Away Auto Lock* Walk Away Auto Lock* When you walk away from the vehicle while carrying the remote transmitter, the doors can automatically lock if the following conditions are met: The remote transmitter is within a

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

2001 Dodge Durango ACCESSORIES & EQUIPMENT' 'Anti-Theft Systems - Dakota & Durango 2001 ACCESSORIES & EQUIPMENT

2001 Dodge Durango ACCESSORIES & EQUIPMENT' 'Anti-Theft Systems - Dakota & Durango 2001 ACCESSORIES & EQUIPMENT DESCRIPTION VEHICLE THEFT SECURITY SYSTEM 2001 ACCESSORIES & EQUIPMENT Anti-Theft Systems - Dakota & Durango Vehicle Theft Security System (VTSS) provides perimeter protection against unauthorized use

More information

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com EM101 EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS LOW FLOW MAGNETIC FLOWMETER

More information

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White. MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM H7/1 Green : (-) 200mA Pulse H7 3 Pin H7/3 Blue : (-) 200mA Unlock White LED Indicator Valet Switch H6 2 Pin

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

Model 300 Installation Guide

Model 300 Installation Guide Model 300 Installation Guide 2000 Directed Electronics, Inc. Vista, CA N431R 3-00 table of contents What Is Included..................... 3 Primary Harness (H1), 12-Pin Connector..... 4 Relay Harness (H2),

More information

C e l l C O M. G S M I n t e r c o m

C e l l C O M. G S M I n t e r c o m C e l l C O M G S M I n t e r c o m Call fixed line phone GSM SIGNAL Call mobile cell phone Accepts any GSM SIM card. Quad band modem. 850 / 900 / 1800 / 1900 MHz Calls up to 3 numbers in sequence GSM

More information

TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE

TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE Manufactured in Australia for Telephone Technical Services PO BOX 675 SPRINGWOOD QLD 4127 PRODUCT DESCRIPTION This User Guide describes the installation and

More information

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1 MEGA 2500 2-WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM Installation Manual MEGATRONI CALIFORNIA, USA MEGA 2500 INSTALL 1 MEGA 2500 INSTALL 2 INSTALLATION DIAGRAM H8: 10 Pin White Mini Connector H8 10

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

COMMERCIAL CONCENTRATED ENERGY ELECTRIC BOILER 22.5 KW TO 180 KW

COMMERCIAL CONCENTRATED ENERGY ELECTRIC BOILER 22.5 KW TO 180 KW ELECTRIC BOILER 22.5 KW TO 80 KW COMMERCIAL CONCENTRATED ENERGY The VOLTMAX line of electric boilers was developed to efficiently supply hydronic heating systems in commercial, institutional and industrial

More information

PJC321, PJC322 PJC321-L, PJC322-L PJC321-MCL2, PJC322-MCL2 S-link Control Panel

PJC321, PJC322 PJC321-L, PJC322-L PJC321-MCL2, PJC322-MCL2 S-link Control Panel SIDE-POWER Thruster Systems PJC321, PJC322 PJC321-L, PJC322-L PJC321-MCL2, PJC322-MCL2 S-link Control Panel Keep this manual onboard! EN Installation and user s manual SLEIPNER MOTOR AS P.O. Box 519 N-1612

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

KEYLESS ENTRY SECURITY SYSTEM:

KEYLESS ENTRY SECURITY SYSTEM: KEYLESS ENTRY SECURITY SYSTEM: 1. TriMark Brain Box module, with programming button and LED (will be seen from exterior of unit through the front windshield, center of dash), fuse and holder is located

More information

LAN Power Supply Module.

LAN Power Supply Module. Revision 1.1 Sept. 2002 1 Contents Model 3000 / Access 4000 LAN Power Supply Module. Standard: P/N: 995050 Enhanced: P/N: 995050ENH INSTALLATION MANUAL Overview... 1 System Requirements and Reporting...

More information

CLIFFORD CONCEPT 300 Wiring Instructions Re-compiled and illustrated by Ray Heffer (www.rayheffer.com)

CLIFFORD CONCEPT 300 Wiring Instructions Re-compiled and illustrated by Ray Heffer (www.rayheffer.com) CLIFFORD CONCEPT 300 Wiring Instructions Re-compiled and illustrated by Ray Heffer (www.rayheffer.com) Wiring Description for the 9-Pin Connector Pin Label Connects to Inputs Outputs 1 Ground (-) Ground

More information

Speed Gate ST-01. Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL

Speed Gate ST-01. Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL Speed Gate ST-01 Double-Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL Speed Gate ST-01 Double-Sided Section STD-01 Assembly and Operation Manual CONTENTS 1 APPLICATION...4 2 OPERATION CONDITIONS...4

More information

AutoControl Pressure Governor

AutoControl Pressure Governor AutoControl Governor OPERATION and INSTALLATION MANUAL MODEL WSD-100: Cummins Electronics Engines-ISB, ISC, ISL, ISM WSD-200: DDEC electronics engines-series 50 and Series 60 WSD-240: DDEC Series 40 engines

More information

PLC Controlled High Performance Automatic Grease Lubricator

PLC Controlled High Performance Automatic Grease Lubricator Rev.0 PLC Controlled High Performance Automatic Grease Lubricator 1. About Pulsarlube PLC Specifications Specifications Grease Pouch Capacity Operating Pressure Power Supply Description 60, 120, 240, 480ml

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Square Proximity Sensor Terminal housing Active face changeable to one of every five Easy to install and same mounting dimensions as a standard style electromechanical limit

More information

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Covers All 430, 440, 441 and CJ Series Advanced Security Systems. INSTALL GUIDE Covers All 430, 440, 441 and CJ Series Advanced Security Systems www.ultrastarters.com Technical Support: 866-698-5872 ext 0 support@ultrastarters.com FCC/ID Notice This device complies with

More information

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016 PSU features. Compliant with the requirements of the

More information

TABLE OF CONTENTS General information... 4 Benefits of the system... 4 OPERATION CONCEPT... 5 Algorithm of deactivation... 5 Authorization with the

TABLE OF CONTENTS General information... 4 Benefits of the system... 4 OPERATION CONCEPT... 5 Algorithm of deactivation... 5 Authorization with the OPERATING MANUAL Dear car owner! Please note that the AUTHOR Alarm s anti-theft devices are not intended for self-installation. We strongly recommend to install and configure the purchased equipment only

More information

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE 7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE Contents Glossary... 3 M40/50RF Motor... 3 SUITE Remote... 3 Battery Installation... 3 Introduction... 4 1) Install the Shade... 4 2) Create the Hub Motor...

More information

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT SAFETY- FLY 700 P FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR.1017.2 MIT USER MANUAL UK Manufacturer Preface : MC elettronica S.r.l. Address : Via E. fermi, 450/486 Fiesso Umbertiano (ROVIGO) - ITALY

More information

DIAGNOSIS AND TESTING

DIAGNOSIS AND TESTING 501-14-1 Handles, Locks, Latches and Entry Systems 501-14-1 DIAGNOSIS AND TESTING Locks, Latches and Entry Systems Refer to Wiring Diagrams Cell 117 for schematic and connector information. Special Tool(s)

More information

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK. 575 Birch Street, Forestville, CT 06010 Phone (866) 322-1237 Fax (866) 322-1233 WWW. LOCKNETICS.COM 390/390-2 DEL INSTALLATION AND PROGRAMMING 390DEL DELAYED EGRESS General Description... 2 Technical Specifications...

More information

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates. Programmable Control board for wings gates www.remotecontrolgates.co.uk Manual for installation Compatible from firmware version BIOS2BT02 CONTROL UNIT BIOS2 1. Introduzione The control unit BIOS2 is particularly

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

MILPOWER SOURCE M130BA-1

MILPOWER SOURCE M130BA-1 UNINTERRUPTIBLE POWER SOURCE SINGLE PHASE - 2kVA M130BA-1 MADE IN THE U.S.A USER S MANUAL East Coast Milpower Source Field Lane, RTE. 106 Belmont, NH 03220 Phone: (603) 267-8865 Fax: (603) 267-7258 West

More information

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1 VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1 VS 315 2 INSTALLATION We recommend insulating all your soldered or crimped connections

More information

Gate & Door Controller with LCD and Intelligent Technology

Gate & Door Controller with LCD and Intelligent Technology 2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent

More information

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS PCS 00 SYSTEM INSTALLATION INSTRUCTIONS PCS - 00 + - POWER 4VDC CW TIME LO NL 4 5 6 ON C&K SDA06 CCW HI RL WHITE BROWN BLACK NC L NC L ON C&K SDA04 4 NO M NO M RESET START 5V 4V COM (0) BLUE SCU-00 Made

More information

Model H30 Operation Manual

Model H30 Operation Manual Model H30 Operation Manual Model H30 Version 1.0 August 1, 2007 2 135 West Davenport Street Rhinelander WI 54501 Phone: 866.441.7997 Fax: 866.278.0036 info@houstonst.com www.houstonst.com 3 Table of Contents

More information

Locomotive Driver Desk. Manual

Locomotive Driver Desk. Manual Locomotive Driver Desk Manual Authors: Dr.-Ing. T. Vaupel, D. Richter, M. Berger Translated by Wolfram Steinke Copyright Uhlenbrock Elektronik GmbH, Bottrop 3rd Edition March 2004 All Rights Reserved Duplication

More information

ILISC515-A Shift Interlock (Manual Lift Door) Ford Transit

ILISC515-A Shift Interlock (Manual Lift Door) Ford Transit An ISO 9001:2008 Registered Company ILISC515-A Shift Interlock (Manual Lift Door) 2015-2018 Ford Transit Introduction The ILISC515-A is a microprocessor driven system for controlling wheelchair lift operation.

More information

Model PRO 9246CH Installation Manual

Model PRO 9246CH Installation Manual Model PRO 9246CH Installation Manual PRE-INSTALLATION NOTES: RF Programmable Features : Feature Selection 1 Flash 2 Flash 3 Flash Default 1st Do L/UL 1 Sec. 3.5 Sec. 1 Sec L, Dbl. U/L 1 Sec. 2nd Accy Lock

More information

Total Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007)

Total Control Board. Installation, Operation and Maintenance Manual. Publication 2949A (GB) (From October 2007) Total Control Board (From October 2007) Publication 2949A (GB) 1108 Freedom from patent restrictions must not be assumed. IMPORTANT PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLATION THIS MANUAL SHOULD

More information

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO Lippert Components, Inc. Informational Publication LIP Sheet - 0182 revd ENTRY DOOR LATCH INFORMATION - SOUTHCO SOUTHCO, Inc. door latches are used in Lippert s Keyless Entry Door systems. All Southco

More information

ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM System Name Power Window Control System Sliding Roof System ENGINE IMMOBILISER SYSTEM PRECAUTION 1. PRECAUTION FOR DISCONNECTING BATTERY TERMINAL NOTICE: When disconnecting the negative () battery terminal,

More information

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you

More information

Aftermarket Interface Module

Aftermarket Interface Module An ISO 9001:2008 Registered Company Aftermarket Interface Module (2015-2018 Ford Transit) AIM514-B High Side Solenoid type Coolant Valve Control AIM515-B Motor Reversing type Coolant Valve Control Introduction

More information

QUICKSTART ESSENTIALS

QUICKSTART ESSENTIALS QUICKSTART ESSENTIALS QS007-01 WORKSURFACE HEIGHT ADJUSTMENT Sit to Stand EON PHOSPHATE CONTROL PANEL GAS SPRING MODEL ACTUATOR MODEL For height adjustment pull lever on gas spring model or use UP/DOWN

More information

victron energy B L U E P O W E R

victron energy B L U E P O W E R victron energy Bus-based power distribution system Installation & Operation manual VE.NET DC victr on ener gy Installation & operation manual Copyrights 2006 Victron Energy B.V. All Rights Reserved This

More information

SCCP PWM Charge Controller/Load Manager Owner s Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual SCCP05-050 PWM Charge Controller/Load Manager Owner s Manual NOTE: Follow instructions in order. Charge batteries at least once a week. Use reducers to connect larger wires disconnect to terminals. battery

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

CX-EMF-2 MULTI-FUNCTION RELAY

CX-EMF-2 MULTI-FUNCTION RELAY ELECTRIFIED S, RELAYS & TIMERS RELAYS & TIMERS ABM MULTI-FUNCTION RELAY FEATURES MICROPROCESSOR CONTROL USER SELECTABLE MULTI-APPLICATION DESIGN PLUG-IN CONNECRS FOR WIRING ACCEPTS UP 7 DRY INPUTS DESCRIPTION

More information