RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

Size: px
Start display at page:

Download "RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa"

Transcription

1 ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. ROOM CONTROL EQUIPMENT RWBa For sequential control of heating and cooling, or cooling/ heating only. Electromechanical actuators provide assured operations. Connection card and prefabricated cables with quick connectors facilitate installation and give immense flexibility. Regular conditioning of valves ensure operation. FUNCTIONS - Control cooling and heating in sequence. - Adapted for room control no unnecessary functions low costs. - Individual temperature control high comfort. - Universal actuator compatible with most types of actuator, with or without adapters. AREAS OF APPLICATION For waterborne climate systems in connection with new installations, expansion and renovation. RWBa has been developed for Stifab Farex water based climate systems. RWBa consists of: Regulator with integrated temperature sensor, electromechanical actuator, valve housing, prefabricated cables with quick connectors and connection card. Regulation function: PI or P (resettable). Supply voltage: 24 V AC. RWBa We reserve the right to change the technical specification. 169

2 STIFAB FAREX ROOM REGULATOR EQUIPMENT ADVANTAGES OF RWBa Sequential control of heating and cooling. The regulator has adjustable regulation function, P or PI. Basic circuit diagram The connection card and prefabricated cables are used with series installation. This facilitates installation and gives a flexible solution. With modified room division only the electrical cables need to be re-routed. Up to 10 actuator pairs (10+10) per regulator. Reliable and energy saving three position electromechanical actuator. The actuator only consumes current during the period it is working (opens or closes). The actuator is not fed with current in both the open and closed positions. The equipment requires no trimming, the operating parameters are pre-programmed for comfort control. The system has clear operating display. The actual operating mode is shown on the regulator and the valve s position is shown on the actuator via the position indicator. Test/Start up function that allows function checks during commissioning. This function also makes it possible to open all valves centrally, which makes venting the system easier. The valves are conditioned regularly to prevent jamming. The sensors for the changeover function can be connected to the regulator, external temperature sensor and currentless, normally closed contacts, for example, a window contact. FUNCTION Sequential control of heating and cooling. With higher temperatures than the set point value the cooling actuator opens the cooling valve and when the temperature drops below the set desired value by 2K the heating valve opens. The control functions are set for PI control. The I section detects the size as well as the duration of the control deviations so that remaining deviations are eliminated. The control parameters are set for comfort control, which means that the temperature can be set within the range 18 C to 26 C with cooling and 16 C and 24 C with heating. The neutral zone between cooling mode and heating mode is 2K. The regulator conditions the valves if they have not moved for eighteen hours. The regulator s pre-programmed Test/Start up function permits control of regulator and actuator functionality. The regulator opens and closes in fixed steps. This also permits all valves on the loop to be opened centrally, for example, when venting the system. Currentless normally open contacts, e.g. the window contact, can be connected to the regulator s screw terminal to set the operating parameters to economy mode or frost protection mode. RWBa, with prefabricated cables and connection card Function Heating requirement Heating valve Output signal/valve mode (% open) 100% 80% 50% Cooling valve 2K Neutral zone Cooling requirement Example: Room temperature = 24 C Valve opens 50% and the regulator starts to acts to Set desired value - 22 Copen or close valves depending on the cooling requirement. Installation RWBa, connection to perimeter unit Farline using factory fitted actuators and connection cards. INSTALLATION Installation is easy to carry out using prefabricated cables and connection cards with quick connectors. See the figure to the right. RWBa, connected to a chilled beam and radiator 170

3 TECHNICAL DATA REGULATOR RWBa RE The regulator consists of a circuit unit, sensor, LEDs and set point potentiometer fitted in a plastic enclosure. Designation: RWBa RE. Temperature: Ambient temperature with storage 25 to +65 C. In operation 0 to +50 C. Labelling: Stifab Farex logo on the cover. Enclosure: ABS - white plastic. Protection class: IP 30. Supply voltage: 24 V AC + 20%, Hz. Terminal block: There are quick connectorsor voltage supply and motor outputs. Other outputs are connected on screws terminals for 0.5 mm 2 cables. Control outputs: 24 V AC, 0.5 A, 1 for heating, 1 for cooling. Other outputs: Normally open contact for the window contact and normally open condensation sensor. Changeover sensor External temperature sensor Power consumption: Regulation function: Neutral zone: Temperature sensor: Setting range: Operating mode: Operating control: Installation: Lead throughs: Delivery setting: 0,5 VA (only the regulator), 15 VA (including 10 actuator pairs). P or PI (resettable), p-band can be set to 2K or 4K. 2k or 4k (resettable) Thermistor C. Knob setting in centre position 22 C (comfort mode). Comfort mode, economy mode and frost protection mode. LEDs. Cooling operation - blue LED. Neutral - LEDs off. Heating operation - red LED. On the wall or 70 mm standard connection box. Not exposed to direct sunlight. Lead throughs must have a minimum diameter of 12 mm to permit routing of the connectioncable to the regulator. See description under the CONNEC- TION INSTRUCTIONS. The product is Ce marked and complies with EU s demands regarding EMC. Regulator RWBa RE Operating mode Operating mode Comfort mode: Neutral zone = 2K 100 Activated by DIL-switches. Economy mode: Neutral zone = 2K Activated by DIL switches and open contact (window contact or the like). Frost protection mode: Neutral zone = 2K Activated by DIL switches and/or open contact (window contact or the like) Operating parameters 20 C 22 C 16 C 24 C Heating 18 C 14 C 22 C Heating 12 C 12 C 12 C Heating 18 C 26 C Cooling 25 C 21 C 29 C Cooling Cooling With connection of the normally open contact (window contact or the like) to the regulator s output D1 the regulator switches between a primary (normally closed contact) and a secondary (normally open contact) depending on the status of the contact. Possible operating modes are: Operating mode 1: from comfort mode to frost protection mode Operating mode 2: from comfort mode to economy mode Operating mode 3: from economy mode to frost protection mode The delivery setting is made with DIL switches according to the description given under CONNECTION INSTRUCTIONS. RWBa 171

4 VALVE ACTUATOR RWBa ST Designation: RWBa ST Labelling: Stifab Farex logo on the cover. Enclosure: ABS - white plastic. Supply voltage: 24 V AC + 20%, Hz. Function: 3 modes, increase/decrease, electromechanical. Connection cable: Supplied with 1.0 m 3 core cable. Power consumption: 0.8 VA Protection class: IP 40. Operating control: 1 = closed valve 0 = open valve Actuator force: 100 N Stroke length: mm Weight: 300 g Connection: Threaded M30 x 1.5 Installation: The valve s actuator connection must not be fitted under the horizontal line. The product is ce marked and complies with EU s demands regarding EMC. VALVE RWBA VD / VE Valves RWBa VD (straight valve) and RWBa VE (angled valve) fit on the system s RWBa ST, which is fitted directly to the valve. Dimensions: see the table to the right. kv - value: see the table to the right. Max working pressure: 1000 kpa Max pressure drop across an open valve: 20 kpa Max pressure drop across a closed valve: 150 kpa Max. supply pipe temperature: 110 C Max concentration of glycol in the water: 40% Presetting the k v -value Setting is done according to the table to the right, see illustration below. Valve actuator RWBa ST Ventil Dim. table DN (inch) 81,4 VD Table k v -value RWBa VD / VE Type Straight 2-way valves VD) M30 x 1.5 3/8 VD110 1, /2 VD115 1, VE DN A B C D E V D110 3/8" V D115 1/2" V D120 3/4" V E110 3/8" V E115 1/2" V E120 3/4" k v -value delivery setting k v -value limit settable (m 3 /h) 3/4 VD120 2, Angled valves (VE) 3/8 VE110 2, /2 VE115 2, /4 VE120 3, Screw in the insert clockwise until it bottoms. 2. Turn the insert anti-clockwise to 0 3. Turn the insert clockwise to the required preset number. Table presetting the k v -value RWBa VD / VE Preset figures VD VD VD VE VE VE

5 CONNECTION CARD RWBa KK Connection card for connecting actuators, transformers and slave units to the regulator. All connections are made using quick connectors and prefabricated cables. Designation: RWBa KK Enclosure: ABS, grey plastic Protection class: IP 20. Labelling: On the enclosure showing the connection and orientation of slave and operating voltage cables. The connection card has a self-adhesive film on the back that makes it easy to install where required. Each connection card has two actuator outputs, one for heating and one for cooling, two slave outputs(signal and power supply) and a regulator input. All connectors on the card are female connectors. See the figure under CONNEC- TION INSTRUCTIONS. TRANSFORMER RWBA TS Double insulated protection transformer. Designation: RWBa TS Enclosure: Fully enclosed Plastic cover Protection class: IP 54. Primary side: 230V AC, Hz. Connection with plug SE Secondary side: 24 V AC, 2.5 A, secondary fuse. Connection cable, length = 1 m, with 2 branches, quick connector 2L (male) for connection to the connection card. The branches are marked with blue and red tape for orientation to the colour codes on the connection card. Installation: Securing holes on the outside of the enclosure or using a bracket against the wall (perimeter wall system). The product is ce Ce marked and complies with EU s demands regarding EMC and LVD. CABLES RWBa KL Cable, operating voltage: RWBa KL - A Prefabricated 2 wire cable 0.5 mm 2 with quick connector (male) for connection of the operating voltage between the connection cards. The cable is available in three standard lengths, 1900, 3200 and 4200 mm. The cable can be joined using a terminal block, see under accessories. Cable, slave control RWBa KL - B Prefabricated 6 wire cable 0.5 mm 2 with quick connector (male) for slave control. The cable forwards the control signal and operating voltage between cards. The cable is available in three standard lengths, 1900, 3200 and 4200 mm. The cable can be joined using a terminal block, see under accessories. 52 Connection card, transformer RWBa KK Cables RWBa TS-1 RWBa KL - A RWBa KL - B RWBa KL - C Selection - maximum cable length The maximum cable length from the transformer connection point to the farthest actuator and maximum cable length from the regulator to the farthest actuator see the formula below. Maximum cable length ( 0.5 mm 2 ) = 672 / (2 ΣP (VA) ) P regulator = 0.5 VA P actuator = 0.8 VA Example 1. 1 regulator and 8 actuators cooling and 8 actuators heating. Maximum cable length = 672 / (2 ( )) = 48.5 m. Exempel rooms with 1 perimeter unit per room, c-c between regulators is 6 m. Tests using two transformers give the overall cable length per transformer: 24 6 / 4 = 36 m (see illustration below). Check with the formula gives: Maximum cable length = 672 / (2 6( )) = 43 m. As cooling and heating actuators have separate cables the maximum cable length will be equal when you have both cooling and heating actuators and when you only have cooling or heating actuators. 36 m 36 m 36 m 36 m Transformer L (end to end) Transformer Cable lengths to perimeter system FARLINE Calculate the requisite cable length between devices by taking the measurement L (end to end as illustrated below) and add 600 mm. Select the closest, longer standard length. Regulator cable RWBa KL - C Prefabricated 6 wire cable 0.5 mm 2 with quick connector (male) for connection of the regulator to the connection card. The cable is available in standard lengths of 1500 and 3000 mm Cable selection and calculation of cable lengths for the perimeter system FARLINE see the description to the right. RWBa 173

6 ACCESSORIES Terminal block for operating voltage cable: RWBT SK - 2L Terminal block with two pins for interconnecting the cable for the operating voltage. Terminal block for the slave control cable: RWBT SK - 4L Terminal block with four pins for interconnecting the cable for the slave signal. One terminal block 2L and one terminal block 4L are required to interconnect cable RWBa KL - B Cable connector: RWBT KT Removable cable connector with male housing, for connection to connection card RWBa KK. Cable connector 2 pin, operating voltage: RWBT KT - 2L Cable connector 3 pin, actuator: RWBT KT - 3L Cable connector 4 pin, control signal: RWBT KT - 4L Cable connector 6 pin, regulator signal: RWBT KT - 6L Quick connector in the regulator (3 x 2 pins) not removable. Accessories Terminal block RWBT SK - 4L and SK - 2L Cable connectors RWBT KT - 2L, 3L, 4L and 6L Screw terminal for actuator RWBT SP Screw terminal for actuator RWBT SP Screw terminal with quick connection to actuator RWBa ST. The screw terminal is connected once the supplied cable has been disconnected (quick connection). External temperature sesnor RWBT TG External temperature sensor, length 2500 mm. Assembly set RWBT CS, clips for changeover sensor External temperature sensor RWBT TG can be used as a changeover sensor by using assembly set RWBT CS. The sensor can be fitted to mm pipes by using the assembly set. The changeover sensor, which is connected to the regulator s screw terminal, is adapted for a 2-pipe system and can work with both cooling and heating with only one valve connected. The temperature that the sensor detects on the supply pipe determines the operating mode the regulator shall work under. External temperature sensor RWBT TG Assembly set for changeover sensor RWBT CS Adapter for motor to work with other makes of valve RWBT AV The adapter makes up the connection between the valve and the actuator. Fits dim. 10, 15 and 20 mm. Actuator RWBa ST with adapter is compatible with the following makes and types of valve: Danfoss RAV, RAV-L, RA 2000 Heimeier Oventrop Markaryd Material: White plastic. The actuator fits directly (without adapter) to all valves with threaded fitting M30 x 1.5 and stroke length <2,5 mm. 174

7 CONNECTION INSTRUCTIONS Black Blue Black Blue Orange Violet Orange Violet Prefabricated cables are marked with colour codes and numbers or colours and white markings. Black Black Blue Orange Violet Connection to connection card RWBa KK Connection to another terminal block Inputs/outputs G: System potential G0: System zero Y1: Actuator heating - open Y2: Actuator heating - closed Y10: Actuator cooling - open Y20: Actuator cooling - closed Outputs with screw terminals on the regulator (even the Delivery settings on the DIL switches must be checked for these). B2 to M: Changeover sensor BI to M: External temperature sensor D1 to M: Normally closed contact, for example, window contact. Strapped on delivery. D2 to M: Normally closed contact, for example, normally closed condensation guard. Strapped on delivery. The outputs D1 and D2 work without current, voltages above 24 V AC can destroy the regulator. Maximum cable length is 100 m. Test/Start up function Activity Signal 1. Heating valve opens 60 s light 2. Cooling valve opens 60 s pulse and blue light 3. Both valves remain open for 60 s and blue pulse 4. Heating valve closes light and blue pulse 5. Cooling valve closes Blue light The delivery settings are activated after the regulator is first switched off and then restarted. Delivery settings of the DIL switches in the regulator Op. Mode 1 Op. Mode 2 Op. Mode 3 Switch: Mode: 1 Op mode select ON ON OFF ON / OFF 2 Op. mode select ON OFF OFF ON / OFF 3 P-band heating: ON = 2K / OFF = 4K ON / OFF 4 P-band cooling: ON = 2K / OFF = 4K ON / OFF 5 Reg. function: ON = PI / OFF = P ON / OFF 6 Neutral zone: ON = 2K / OFF = 4K ON / OFF 7 External temp. sensor (also see terminal8!) ON / OFF 8 Internal temp. sensor (also see terminal7!) ON / OFF 9 Run-time actuator: ON = 150 s / OFF = 45 s ON / OFF 10 Test-/start up function ON / OFF Delivery settings are marked in bold. Operating mode Primary mode Secondary mode Operating mode 1: from comfort mode to frost protection mode Operating mode 2: from comfort mode to economy mode Operating mode 3: from economy mode to frost protection mode Transition from primary mode to secondary mode takes place when the currentless contact between D1 and M breaks. Changes to the delivery settings are activated after the regulator is first switched off and then restarted. RWBa 175

8 SPECIFICATION Room control equipment type RWBa with electromechanical actuator for sequential control of heating and cooling. Specification Product Regulator Valve actuator RWBa RE RWBa ST Valve RWBa aa - bb Design: Straight = VD Angled = VE Size: 15, 20, 25 Accessories Terminal block cables Two pin= 2L Four pin= 4L Cable connector (male) Two pin = 2L Three pin = 3L Four pin = 4L Six pin= 6L Screw terminal Assembly set External temperature sensor RWBT SK - a RWBT KT - a RWBT SP RWBT CS RWBT TG Connection card RWBa KK Transformer RWBa TS - a Type: Without bracket = 1 Withbracket = 2 (perimeter system) Cable RWBa KL - a - bbbb Type: Operating voltage (2-wire) = A Slave cable (6 way) = B Length: 1900, 3200 and 4200 mm. Adapter, actuator/valve To valve type: Danfoss RAV Danfoss RAV-L Danfoss RA 2000 Heimeier Markaryd MNG Oventrop RWBT AV- aaaaaaaaa Regulator cable (6-way) Length: 1500 and 3000 mm. RWBa KL - C -aaaa Ordering example: Room control equipment for series connection of 7 FARLINE perimeter units c/c 2400 mm: 1 x regulator RWBa RE, 1 regulator cable RWBa KL-C-1500, 1 x transformer RWBa TS-2 and 6 slave cables RWBa KL - B Room control equipment for series connection of 6 beams (c-c 3600 mm) for cooling and heating: 1 regulator RWBa RE, 1 regulator cable RWBa KL-C-1500, 12 valve actuators RWBa ST, 12 valves RWBa VD-15, 6 connection cards RWBa KK, 5 slave cables RWBT KL - B and 1 transformer RWBa TS-1. 1 terminal block for the operating voltage cable RWBT SK - 2L is also required if the transformer is to be connected between the connection card and slave control cable. Alternatively with connection to a junction box with screw terminals: 1regulator RWBa RE, 1 regulator cable RWBa KL-C-3000, 12 valve actuators RWBa ST, 12 valves RWBa VD-15 and 1 transformer RWBa TS-1. Note that junction boxes and cables are not supplied. 176

lindab comfort Regula Control er

lindab comfort Regula Control er lindab comfort Regula Controller Regula Controller Control equipment for waterborne cooling and heating systems. Use Regula Mono, Duo and Regula Lon control the cooling and heating of a room in sequence

More information

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems EMOtec Actuators Thermal actuator for heating, ventilation, and air conditioning systems IMI HEIMEIER / Thermostats & Actuators / EMOtec EMOtec The EMOtec thermal actuator with position indicator (NC)

More information

SSA955. Synco living Radiator Control Actuator

SSA955. Synco living Radiator Control Actuator 2 700 Synco living Radiator Control Actuator SSA955 RF-controlled actuator for radiator valves RF communication based on KNX standard (868 MHz, bidirectional) Battery-powered by commercially available

More information

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:

More information

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control EMO T Actuators High performance thermoelectric actuator For ON/OFF or PWM control IMI TA / Actuators / EMO T EMO T Used in conjunction with small terminal valves e.g. TBV-C and TA-COMPACT-P or thermostatic

More information

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS kit Compact Change Over - 6-way switch valve with motor QUICK FACTS Enables heating & cooling in products with only one heat exchanger circuit Precise flow regulation For 4-pipe cooling/heating system

More information

Accessories STRA Room Controller

Accessories STRA Room Controller Accessories STRA Room Controller External temperature sensor, STRZ-5-b Technical data room sensor: STRZ-5-5 C PT, DIN class B IP Technical data external sensor: STRZ-5-2 - +7 C PT, DIN class B Technical

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1. HMF Single Duct Cabin Unit for Passenger And Crew Cabins Available as network compatible The Halton HMF is an automatic or semi-automatic single duct cabin unit with intergrated reheater. Automatic operation

More information

Temperature Controller (Heat Pumps)

Temperature Controller (Heat Pumps) 3 345 Temperature Controller (Heat Pumps) For comfort control in HVAC systems RWD31 RWD41 Stand-alone electronic temperature controller Four 2-position (On/Off) outputs Easy adjustment of parameters via

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46.. 4 863AP Electromotoric Actuators for zone valves VVI46.., VXI46.., VVS46.. and VXS46.. SFA21.. SFA11U SFA71 SFA21.. AC 230 V operating voltage, 2-position control signal SFA11U AC 110 V operating voltage,

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins HMR DUAL DUCT CABIN UNIT For passenger and crew cabins APPLICATIONS Halton HMR is pressure independent dual duct cabin unit. The airflow is continuously measured from the warm air spigot, as well as for

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Electromotoric Actuators

Electromotoric Actuators 4 863 Electromotoric Actuators for zone valves VVI46, VXI46, VVS46 and VXS46 SFA21/18 SFA71/18 SFA21/18 AC 230 V operating voltage, 2-position control signal SFA71/18 AC 24 V operating voltage, 2-position

More information

Valves and Actuators

Valves and Actuators Valves and Actuators Summary F-10-06 13 Dec 2004 V241 V311 V211 V341 V232 Data sheet 2-way plug valves V241 DN 15 DN 50, Bronze F-20-50 V211T DN 15 DN 50, Nodular iron F-20-55 V212T DN 25 DN 50, Nodular

More information

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems T-6-way valve NPT threads Standard control valves 6-way valve for change-over systems IMI T / Control valves / T-6-way valve NPT threads T-6-way valve NPT threads The 6-way valve solution enables various

More information

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V 4 637 OpenAir TM Air damper actuators Rotary version, modulating, with spring return, AC 24 V GCA16...1 Electromotive rotary actuators, DC 0...10 modulating control signal, nominal torque 16 Nm, spring

More information

HERZ Electronic room thermostat analog and digital

HERZ Electronic room thermostat analog and digital Dimension in mm 3 F799 11-3 F799 14 HERZ Electronic room thermostat analog and digital Data sheet for F799, Issue 0317 3 F799 15 3 F799 18 Mounting plate Page 1 Technical data 3 F799 11-14 3 F799 15-18

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6

More information

AXS 215S: Continuous actuator for unit valves, with stroke indicator

AXS 215S: Continuous actuator for unit valves, with stroke indicator AXS 215S: Continuous actuator for unit valves, with stroke indicator How energy efficiency is improved Reliable, precise actuation in efficient control systems Features Fitted to the valve using no force

More information

Control valves with electric actuators up to 90 C PN

Control valves with electric actuators up to 90 C PN Features Suitable for the control of hot and chilled water (0...+90 C) in drinking water systems Valves with DVGW test mark reg. no. DW-6340BP0198 acc. latest German Drinking Water Ordinance (TrinkwV 2001)

More information

TA-6-way valve. Standard control valves 6-way valve for change-over systems

TA-6-way valve. Standard control valves 6-way valve for change-over systems TA-6-way valve Standard control valves 6-way valve for change-over systems IMI TA / Control valves and Actuators / TA-6-way valve TA-6-way valve The 6-way valve solution enables various control set-ups

More information

Rotary actuators for ball valves

Rotary actuators for ball valves s ACVATIX Rotary actuators for ball valves Electromotoric rotary actuators for modulating control. Used in heating, ventilation and air conditioning plants. For 2-port and 3-port control ball valves, internally

More information

EMO TM. Actuators High performance proportional actuator For modulating control

EMO TM. Actuators High performance proportional actuator For modulating control EMO TM Actuators High performance proportional actuator For modulating control IMI TA / Actuators / EMO TM EMO TM A proportional thermoelectric actuator which, when used together with the TA-Modulator,

More information

Actuators for small valves

Actuators for small valves Actuators for small valves with 5.5 mm nominal stroke 4 891 SSB31... SSB81... 80130 80117 SSB... without auxiliary switch SSB...1 with auxiliary switch Electro-mechanical actuators for valve types VMP45...,

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

Condensation monitor

Condensation monitor QXA2101 QXA2100 Condensation monitor QXA2100 QXA2101 Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power. Can also be used with extension module AQX2000

More information

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied

More information

RC-DO. Room controllers with display and manual forced ventilation function

RC-DO. Room controllers with display and manual forced ventilation function revision 10 2017 RC-DO Room controllers with display and manual forced ventilation function RC-DO is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating HML Airflow Unit for Large Volumes with Centralized Airflow Heating Available as network compatible Halton HML is an airflow unit for large air volumes with centralized airflow heating. The unit can be

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 SQL33 Electromotoric Actuators for valves with 90 angle of rotation SQL33 operating voltage AC 230 V SQL33 operating voltage AC 230 V operating voltage AC 24 V 3-position control signal Nominal angle

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

Electromotoric Actuators

Electromotoric Actuators 4 505 SQL3500 SQL8500 SQL36E Electromotoric Actuators for VKF46, VKF46 TS butterfly valves SQL3500 SQL8500 SQL36E SQL3500, SQL36E operating voltage AC 230 V, 3-position control signal SQL8500 operating

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Air damper actuators

Air damper actuators 4 626 OpenAir TM Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GBB13...1 GBB33...1 Electromotive rotary actuators for three-position control, nominal torque 20 m, operating

More information

ZONE CONTROLE / 2-WAY

ZONE CONTROLE / 2-WAY ZONE CONTROLE / 2-WAY PRESSURE INDEPENDENT BALANCING AND CONTROL VALVE ON/OFF High-performing and compact, these pressure-independent temperature control valves for variable flow heating and cooling systems,

More information

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

2-Port and 3-Port Zone Valves, PN16

2-Port and 3-Port Zone Valves, PN16 4 867 2-port valves MVI421.15 to MVI421.25 2-Port and 3-Port Zone Valves, P16 3-port valves MXI421.15 to MXI421.25 MVI421... MXI421... Operating voltage C 230 V, 2-position control signal Spring return

More information

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers OpenAir TM Actuators for Fire and Smoke Protection Dampers GRA126.1E/... GRA326.1E/... Electric motor driven actuators for 2-position control, nominal torque 4 Nm, with spring return to failsafe position,

More information

Solenoid Valve DF-SB-series

Solenoid Valve DF-SB-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY OPEN Solenoid Valve DF-SB-series The DF-DB is a semi-direct operated 2/2-way solenoid valve. The valve is normally open. The solenoid valves have an orifice of 16

More information

BRC

BRC ------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings

More information

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications Description VG series accurately regulate the flow of water or steam in response to the demand of a controller in heating,ventilating and air conditioning systems. These valves are available in normally

More information

HERZ Motorised Actuator

HERZ Motorised Actuator HERZ Motorised Actuator Data sheet for HVACT Issue 1017 Dimensions Models HVACT24-01 HVACT230-01 HERZ Motor Valve Drive, Floating 3-point, M28 x 1.5, 24 V, 50 Hz actuating force 140 N, operating voltage

More information

Electrical Actuators

Electrical Actuators OEM Electrical Actuators SSY319 for valves VXG48, VXB489R, VXI48 VVP459, VXP459, VMP459, VVG549 AC 230 V operating voltage, 3-position control signal Positioning force 300 N Manual override with indication

More information

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators OpenAir GQD Series Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled

More information

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD General information AC 01.2 Actuator controls in SIL version for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR.2 type range. Information on SIL features

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION Master Slave 1 Slave (n + 1) Master Slave 1 Slave (n + 1) Simplified Master / Slave operation GENERAL is a CIAT electronic control system designed to control non-independent air conditioning terminal units

More information

SAV Electronic Valve Actuator

SAV Electronic Valve Actuator Document No. 155-548 Non-spring Return, 24 Vac/dc, 3-Position Control Description The SAV Non-spring Return (NSR), Electronic Valve Actuator requires a 24 Vac/dc supply to provide three-position (floating)

More information

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation ADRIATIC VF Climate beam Adriatic Adriatic is an enclosed climate beam with integrated

More information

2-Port and 3-Port Zone Valves, PN 16 / 20

2-Port and 3-Port Zone Valves, PN 16 / 20 4 867 2-port valve MVI421.15 to MVI421.25 3-port valve MXI421.15 to MXI421.25 2-Port and 3-Port Zone Valves, P 16 / 20 Max. permissible pressure 2000 kpa MVI421.. MXI421.. Operating voltage C 230 V, 2-position

More information

PGK Rectangular duct coolers for cooled water

PGK Rectangular duct coolers for cooled water Rectangular duct coolers for cooled water Rectangular duct coolers for cooled water The with rectangular duct connection uses chilled water as the energy carrier and is used for cooling the ventilation

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends

More information

Air damper actuators

Air damper actuators 4 654 OPEN AIR Air damper actuators Linear version, three-position control, AC 24 V or 230 V GDB..3..2 GLB..3..2 Electric motor-driven linear actuators for three-position control, nominal linear force

More information

Solenoid Valve ST-SA-series

Solenoid Valve ST-SA-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-SA-series The ST-SA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. The body material can be brass or stainless

More information

Solenoid Valve DF-SA-series

Solenoid Valve DF-SA-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve DF-SA-series The DF-DA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. These valves have an orifice of 16 to

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers 4 617 OpenAir TM Actuators for Fire and Smoke Protection Dampers GGA126.1E/.. GGA326.1E/.. Electric motor driven actuators for 2-position control, nominal torque 18 Nm, with spring return to failsafe position,

More information

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves - Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting

More information

VA-7000 SERIES ACTUATOR

VA-7000 SERIES ACTUATOR VA-7000 SERIES ACTUATOR DESCRIPTION VA-7000 series actuator is electromechanical product, and can be mounted on VB-7000 series valves. If with different connectors, it can be fitted with other kinds of

More information

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals IO Input/Output Modules IO-ABM4 Analogue Override Module Description IO-ABM4 Analogue Override Module Intended for applications which require independent manual override of analogue output channels from

More information

Actuators for Fire Protection Dampers

Actuators for Fire Protection Dampers 4 620 OpenAir TM Actuators for Fire Protection Dampers GNA126.1E/T. GNA326.1E/T. Rotary version, 2-position control, with spring return and ready connected temperature monitoring unit, / DC 24 48 V / AC

More information

Reliable season change

Reliable season change New perspectives with Danfoss Saginomiya 4 - Way Reversing Valves Reliable season change, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants

More information

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection ADAPTTM Sphere Active communicative, supply air diffuser for the WISE system Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring,

More information

Electromotoric actuators

Electromotoric actuators 4 573 SQS35.50, SQS35.53, SQS65.5 with spring return function, without manual adjuster ACVATIX Electromotoric actuators for valves with 5.5 mm stroke SQS35.00, SQS35.03, SQS65, SQS65.2, SQS85.00, SQS85.03

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

LK Manifold Shunt VS2

LK Manifold Shunt VS2 LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.

More information

TDU.3 floor distribution unit SK

TDU.3 floor distribution unit SK SK General description and application The is intended for two pipe horizontal heating systems and includes connecting, measuring, regulating and distribution functions. The TDU.3 is easily installed on

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

Actuators for modulating control AME 110 NL, AME 120 NL

Actuators for modulating control AME 110 NL, AME 120 NL Actuators for modulating control AME 110 NL, AME 120 NL Description The actuators are used together with automatically balanced combination valve type AB-QM for DN 10-32. The actuator can be used with

More information

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15

More information

2-Port and 3-Port Zone Valves & Actuators, PN16

2-Port and 3-Port Zone Valves & Actuators, PN16 2-port valve & actuator MVI421../2 3-port valve & actuator MXI421../2 2-Port and 3-Port Zone Valves & ctuators, P16 MVI421../2 MXI421../2 Operating voltage C 230 V, 2-position control signal Spring return

More information

Max. Input Power (W) Inrush Current (A pk /µs)

Max. Input Power (W) Inrush Current (A pk /µs) Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.

More information

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box HME SINGLE DUCT CABIN UNIT Sound attenuator and balancing box MATERIALS APPLICATIONS Halton HME can be used for air distribution and sound attenuation in various applications such as suites and pantries.

More information

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Document No. 155-507 Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Description The Flowrite 599 Series SAX Non-spring Return (NSR), Electronic Valve Actuator

More information

PNEUMATIC CYLINDERS CYLINDERS ISO solutions SERIES 21 SERIES 21 CYLINDERS ISO 15552

PNEUMATIC CYLINDERS CYLINDERS ISO solutions SERIES 21 SERIES 21 CYLINDERS ISO 15552 PNEUMATIC CYLINDERS 1 2 3 4 SERIEs 21- General Information 32-100 mm diameter 21 series cylinders are manufactured to ISO 15552 standard which specifies interchangeable mounting dimensions. The cylinder

More information

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Electronic suction modulating valves type KVS

Electronic suction modulating valves type KVS MAKING MODERN LIVING POSSIBLE Technical brochure Electronic suction modulating valves type KVS KVS is a series of electronic suction modulating valves for AC transport and refrigeration applications. Accurate

More information

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick 2017 3 Table of contents ADVANTAGES OF THE NEW ProClick GENERATION...4 INFORMATION ABOUT PACKAGING AND DELIVERY...5

More information

10V. the rack of the oil pump must be on the

10V. the rack of the oil pump must be on the P.E.D 20.. ESG2002 series ELECTRONIC GOVERNOR INSTRUCTION A1000C-W ELECTROMAGNETIC ACTUATOR Before inst al l el ectromag neti c, p lea se inspect that the rack of the oil pump shouldn' t be stuck in any

More information

Electro-hydraulic actuators for valves

Electro-hydraulic actuators for valves 4 564 Electro-hydraulic actuators for valves with a 40 mm stroke SKC32... SKC82... SKC62 SKC60 SKC32... Operating voltage AC 230 V, 3-position control signal SKC82... Operating voltage AC 24 V, 3-position

More information

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F ADAPTTM Free Active communicative, supply air diffuser for the WISE system, ADAPT F Quick facts Supply air diffuser with an active damper Pressure-dependent and cleanable Integrated sensor module Simple

More information

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve Product data sheet 5.1 51.364 AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve How energy efficiency is improved Automatic adaptation to ball valve, precise activation

More information

CWK Circular duct coolers for cooled water

CWK Circular duct coolers for cooled water Circular duct coolers for cooled water Circular duct coolers for cooled water duct coolers are designed for using cooled water as the cooling medium and are used for cooling the ventilation air in ventilation

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

GDB..3..1A GLB..3..1A

GDB..3..1A GLB..3..1A 4 624 OpenAir Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GDB31A GLB31A Electric motor-driven actuators for three-position control, 5 / 10 Nm nominal torque, AC 24

More information

High Capacity Valve Body, Type RA-G

High Capacity Valve Body, Type RA-G Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 Electromotoric Actuators for valves with 90 angle of rotation operating voltage AC 230 V 3-position control signal Nominal angle of rotation 90 Auxiliary switch and potentiometer for extra functions

More information

Pressure independent balancing and control valve For ON/OFF control

Pressure independent balancing and control valve For ON/OFF control KT 512 Pressure independent balancing and control valve For ON/OFF control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE High-performing and compact, these

More information

Power supply kit (70 W)

Power supply kit (70 W) Cerberus FIT Power supply kit (70 W) FP120-Z1 This standalone power supply is intended for decentralized supply to external devices. FP120-Z1 has an integrated operating and fault indicator, and makes

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information