1 ΕΓΧΕΙΡΙΔΙΟ ΤΟΠΟΘΕΤΗΣΗΣ & ΡΥΘΜΙΣΗΣ ΑΥΤΟΜΑΤΩΝ ΠΟΡΤΩΝ ΘΑΛΑΜΟΥ ASSEMBLING & REGULATION INSTRUCTIONS FOR AYTOMATIC CABIN DOORS

2 CABIN DOORS

3

4 INDEX PARTS DESCRIPTION 26 POSITION OF THE OPERATOR IN THE CABIN 26 ADJUSTMENT OF CLEAR OPENING IN CENTRE PARTING DOORS 27 ADJUSTMENT OF CLEAR OPENING IN SIDE OPENING DOORS 27 INSTALLATION OF GUIDE SHOES AND HANGERS 28 ADJUSTMENT OF PANELS 28 ADJUSTMENT OF WHEELS 29 LANDING DOOR COUPLING 29 CORRECT ADJUSTMENT BETWEEN CLAMP AND RETAINER 30 LOCKING DEVICE 30 ELEMENTS SITUATION 31 VVVF-4+ MODULE Programming 33 Inputs 34 Programming Examples 39 Technical Features 40 Start Up Protocol & Autoadjustment Of Vvvf (Inverter) 41 POSSIBLE PROBLEMS & SOLUTIONS 42 PREVENTIVE MAINTENANCE 43

5 26 PARTS DESCRIPTION 1 Fixation bracket 2 Operator 3 Plate 4 Panels 5 Tread 6 Tread support 7 Toe guard POSITION OF THE OPERATOR ON THE CABIN 1. Place the brackets in the guide tracks situated in the cabin roof (fig. 2) 2. Place the operator 220mm higher than the clear height of the cabin (fig. 1). 3. Tighten the operator to the brackets (fig. 2). 4. Let 30mm between the front part of the cabin and the outside of the operator regulated with the brackets (fig. 3). 5. Fix the brackets in the guide tracks.

6 27 ADJUSTMENT OF CO. IN CENTRE PARTING DOORS Slow plates: 1. Place the slow plates at the operator extremes. 2. Check that distance between them is X.(fig.1) 3. Tighten the air cord clamps (fig. 2). Fast plates: 1. Place the fast plates in flush position with the slow plates. 2. Tighten the air cord clamps (fig. 2). * X = CO + 45mm (In case of fire protected panels) *X = CO + 30mm (In case of non fire protected panels) Adjust the opening of the door by the slots of the top of the hanger plates. ADJUSTMENT OF CO. IN SIDE OPENING DOORS 1. Place the flush plates in open position. 2. Check that between the extreme plate and the end of opening there is a distance of X*, as shown fig. 1. Use the slots of the top plate for adjusting the door (see figure 1). 3. Once the fast plate is in the flush position with the slow plate, fix the syncronization cord (fig. 2).

7 28 INSTALATION OF GUIDE SHOES AND HANGERS Guide shoes (fig. 1) and hangers (fig. 2) installation in panel procedure. ADJUSTMENT OF PANELS The following procedure is the same for any type of cabin door (Central or side opening). 1. Once the panels are placed into their corresponding plates, slide them through the side they open till they are raised with the frames. 2. Tighen the nuts that hold the plates with the hangers (fig. 1). 3. Straigthen the panels with the help of the hanger nuts until the panel is parallel to the post (fig. 1). Check that between tread, between panel and panel, and between panel and post it exist a distance of 5mm. (fig. 2) Alignment of panels: The panels should slide smoothly in the tread. If for any reason the panels do not slide smoothly, follow these instructions: 1. Disassemble the inferior guides. 2. Straigthen the panels to remain parallel to the tread. 3. Assemble the guides.

8 29 ADJUSTMENT OF WHEELS 1. The adjustment will be made by the inferior wheels (eccentric), rotating the shaft we can adjust the force done to the track. 2. This adjustment may be done with an allen wrench of 5 mm and the flat key. An excessive tightening could stop the panel. Wheels are adjusted in factory, only should be regulated in case of bad functioning. LANDING DOOR COUPLING The cabin door includes the moving skate that does the opening of the landing door. When the cabin door is closed, the moving skate remains closed, so that while the cabin is moving it does not work with the landing locks (fig.1). Before the opening manoeuvre, the moving skate opens and unlocks the landing lock so that it can start the opening and closing of the landing door. In the closing cycle, the movements will be other way round, moving the skate while closing, and closing the skate to free the landing lock, so that the landing door will be ready to close and the cabin free to move. The correct position of the skate is centred in relation with the rollers of the landing lock.

9 30 CORRECT ADJUSTMENT BETWEEN CLAMP AND RETAINER Once the skate is placed (145mm between the end of the plate and the shaft of the skate), in locked position, adjust the clamp-retainer set by the slots (8 x 25) of the support with a gap of 0,5 mm in the horizontal and vertical shaft. Doors 4 panels between CO 600 until CO 915 the measure is 80mm. LOCKING DEVICE Figure A1 and B1 correspond to a lock set and figures A2 and B2 show an open position. In these drawings we can notice the correct situation of the locking mechanism parts. 1. Locked position, between landing cam and movement bushing should be 10mm to allow the cabin fit (fig. A1 and B1). 2. Check when cabin is in the floor the locking device and cam work allowing a correctly opening of the door (fig. A2 and B2).

10 31 ELEMENTS SITUATION D - Distance between treads = 30mm

11 32 TECHNICAL MANUAL & ELECTRONICAL MODULE REGULATION VVVF-4+

12 33 PROGRAMMING 1 DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any of the above switch selections, the Mains Supply to the VVVF-4+ unit MUST be switched OFF and ON again to read the new programming. The switches functions are: 1 & 2 Inputs: ON: 1 Input The door control unit will be controlled by a single input. Any voltage between 12 to 250 volts AC or DC applied between terminals 8 & 10 will open the doors. Without any signal the door remains open. In the contrary the door remains close. OFF: 2 Inputs The door control module will be controlled by two independent inputs. Any voltage between 12 to 250 volts AC or DC applied between terminals 8 & 10 will cause the doors to close. And between terminals 12 & 10 will cause the doors to open. In the absence of a signal, the doors will remain static. If both inputs are applied then the open signal has priority Automatic / Semiautomatic: ON: Automatic: Operators with skate (automatic landing). In this case a special movement is made for locking and unlocking the skate OFF: Semiautomatic: Operators without skate (Semiautomatic landing door). Rotation sense (photocell): ON: The control unit is expecting to control left hand or centre opening doors. OFF: The control unit is expecting to control right hand opening doors. (Special Note: The sense is defined from the outside of the car, refering to the direction taken when the door is opening.) Master and Slave: ON: Master: The door control unit will execute instructions directly. Example: operation of the Photoelectric Detector will cause the doors to re-open immediately under control of the door control unit. OFF: Slave: There is no automatic re-open movements. The photocell will only react to instruction given by the main lift controller by the inputs. Example: operation of the Safety Edge Detector will cause the door operator module to give a signal to the main lift controller via the PHOTOCELL (36, 37, 38) output. The main lift controller then must remove the close signal and put the open signal.

13 34 INPUTS POWER INPUTS V SINGLE PHASE AC (5, 6, 7): The circuit has been designed to operate on a mains supply of 230 Volts AC (+10%,-15%, 50 or 60 Hz). The unit will consume approx 1 Amp from the supply. In the case of using the new External Emergency Passenger Release System the connection of the power from the main supply (230V) is done directly on the unit (3 NEUTRAL - 2 GROUNDING - 3 PHASE). From there onwards through the interconnection between of the 2 boxes (VVVF & Emergency Unit ) the power is trasmitted to VVVF (page 35). CONTROL INPUTS (8, 9, 10, 11, 12): The circuit can work with external voltage inputs or by means a volt free contact input. It is important that the Door Operator Module has a GOOD EARTH CONNECTION. 12. Opening Signal: Is an isolated signal with an impedance of 20 komh and a sensibility from 12 to 250V. used for ordering the door. If we use the control with only one input, it will be closing signal and door will open Volts: Is the negative pole of 12V. When using an internal voltage it should bridged to common (10). 10. Common: Is the reference used for the two inputs Volt: Isolated 12 Volts output available to control the door via a volt free contact. Features are: a. This supply must only be used for this purpose. b. This contact must be isolated from any other power supply. 8. Close signal: It has the same characteristics as the open signal. SERIAL PORT (13, 14, 15, 16): The serial port is used to connect with external devices like the diagnostic console, interfaces and future expansion devices. Operating speed Baud, current loop.

14 35 PHOTOCELL (17, 18, 19, 20): One of the most relevant characteristics of this control is the optional incorporation of a photocell. It is composed by a emitter and receptor infrared. OTHER INPUTS (26, 21, 25, 23): 26. Landing signal: This input is for connecting the external emergency current supplier that allows the opening manouvre in the case of power failure by a battery of 12V, able to give power during 15 seconds for a passengers rescue. 21. Reopening: This signal is for installing the cabin door swich or an external barrier. This signal has priority to the closing signal. Use contacts free on tension. For activating close one contact with the main supply +12V. (23). 25. Slow Closing: This input orders to the operator to close the door slowly regardless of the barrier and control signs. Is created for working with detection of fire centres V. COM: This terminal is used for giving with an isolated contact a reopening order or a slow closing. Always use contacts free of tension and usually open.

15 36 EMERGENCY SUPPLY INPUTS ( ) AND INTERCONNECTION WITH VVVF The KLEFER VVVF can be connected with an optional External Emergency Passenger Release System powered by a 12V battery. In the case of Power Failure the battery provides sufficient power to release trapped passengers. The Door opening manouevre is controlled by a free voltage contact, applied between terminals 66 & 67. Special attention should be paid to the following points: The connection of the power from the main supply (230V) is done directly on the Unit. ( 3-Neutral 2 Ground 1 Phase ). From there onwards through the interconnection of the two boxes (VVVF & Emergency Unit 5-6-7), the power is transmitted to the VVVF4. On the connections 66 & 67 of the Emergency Unit connect the magnetic Normally Open Switch (NO), which through the assistance of a magnetic belt closes the circuit. Special attention should be paid to the connection of the battery. On connector 28 of the Emergency Unit connect the negative pole and on connector 29 the positive. In any other case the 20A fuse will be burned. The Battery automatically recharges itself, once its capacity drops below 70%, and may take up to 48 hours. The situation of the battery is indicated through a led on the Emergency Unit showing the following three different statuses. 1. When the led is ON it means that battery is charging. If this lasts for more than 48 hours the battery is defective and should be replaced (2Ah and above). 2. When the led is flashing everything is operating properly. 3. When the led is flashing every 15 seconds a cut in electricity has occurred.

16 37 OUTPUT RELAYS AND LED INDICATORS (from 30 to 41): Output relays have been provided to give continuous information to the main lift controller concerning the status of the doors. One 5 Amp/250 Volts volt free change over contact is provided on each relay that may be used by the main lift controller to pilot such information as doors fully opened, doors fully closed, Photoelectric detection, obstruction in the doorway and door control O.K.. Opened: Led indicator and relay activated when the doors are fully open. Closed: Led indicator and relay activated when the doors are fully closed and locked. Photocell: Led indicator and relay activated when the photocell or the reopening input is operated. Obstruction: Led indicator and relay activated when an obstacle is detected that stops the doors from closing. The signal will reset when the doors reach the opened or closed position. Status: Blinking led indicating proper working conditions.

17 38 TEST PUSHBUTTON (50): Operation of the Test pushbutton will cause a door open or close cycle. AUTOADJUSTMENT PUSHBUTTON (51): The Autoadjustment pushbutton is used to set up the doors. The doors will do 3 complete movements at first the doors will close completly, then the doors will open slowly counting the pulses from the encoder built into the drive motor until they reach the open mechanical stop, and after a short delay the doors will close. From the information gained the microprocessor will calculate the acceleration and deceleration ramps and the bracking torque required to give the optimum control of the doors. Once the autoadjustment has been completed the parameter are stored in non- volatile EEPROM and will be used to calculate the optimum performance. The doors will open slowly for the first operation after power has been removed from the door control unit. Autoadjustment only needs to be used when setting the initial parameters or when changes such as connecting or removing the Fermator Safety Detector are made. For Advanced Start Up Protocol & Autoadjustment of the VVVF (INVERTER) see Appendix I CLOSE SPEED (52): The door closing speed can be independently adjusted from 150 mm/s upto 600 mm/s. OPEN SPEED (53): The door opening speed can be independently adjusted from 200 mm/s upto mm/s. SAFETY (54): This potentiometer is used to set the closing pressure onto an obstacle in the doorway. The closing pressure can be set between 40 and 150 Nw. ENCODER (55): An integral quadrature pulse encoder is connected to this input. The purpose of the encoder, which is situated inside the motor, is to inform the control of the exact position and speed of doors. MOTOR (56): Output to the 3 phase motor varying the voltage and frequency to control speed and torque. ON/OFF SWITCH (57): Disconnects the unit from the 230 Volts AC mains supply. Caution: When the supply is switched off, capacitors in the control system will remain charged for a short time. Allow 60 seconds before handling the Control Card or Motor.

18 39 PROGRAMMING EXAMPLES MASTER: 1 INPUT Configuration 1. ON: 1 Input. 2. Depends on type of door. 3. Depends on type of door. 4. ON: Master photocell. Inputs 1. (8) Close Closes the doors with voltage between terminals 8 & 10. Open the doors when the voltage between terminals 8 & 10 is removed. 2. ( ) Photocell Doors will reopen if the photocell beam is broken. 3. (21-23) Reopening Doors will not close if this signal is active. SLAVE: 2 INPUTS Configuration 1. OFF: 2 Inputs. 2. Depends on type door. 3. Depends on type door. 4. OFF: slave photocell. 4. Obstacle Door will open if an obstacle is detected by the motor ceasing to rotate. 5. (25-23) Slow Closing Closes regardless of the state of the photocell. Priorities 1. (21-23) Reopening. 2. Obstacle. 3. (25-23) Slow Closing. 4. ( ) Photocell. 5. (8) Close. Inputs 1. (8) Close Closes the doors with voltage between terminals 8 & (12) Open Open the doors with voltage between terminals 12 & 10. Pryority to close. 3. ( ) Photocell Does not re-open the doors when activated but provides signal to main controller via the Photocell relay. 4. (21-23) Reopening Doors will not close if this signal is active. 5. Obstacle Doors will not re-open if an obstacle is detected by the motor ceasing to rotate. 6. (25-23) Slow Closing Closes regardless of the state of the photocell. Priorities 1. (12) Open. 2. (21-23) Reopening. 3. (25-23) Slow Closing. 4. (8) Close.

19 40 TECHNICAL FEATURES POWER SUPPLY AC voltage range v +10%, -15%. AC/DC Frequency supply Hz Minimum supply...70 ma-13 W Open door power...0,6 A-80 W Nominal power... 0,93 A-140 W Maximum power... 1,38 A -190 W INVERTER Carrier frequency KHz Frequency range...0, Hz Voltage range V AC III Maximum output current... 4 A Positional control...quadrature encoder MOTOR Asynchronous three phase...6 poles Voltage supply V Power W Thermic class...b-130 C Nominal speed RPM INPUTS Impedance...20 KOhm Voltage V AC/DC OUTPUTS Contacts...Switched R. contact mw Swich time...5 ms Output current...5 Α max Voltage V PRESTACIONES Open Speed mm/s Close speed mm/s Maximum acceleration mm/s 2 Safety force N adjustable Maintenance torque (Opened Door) Nm/cm

20 START UP PROTOCOL & AUTOADJUSTMENT OF THE VVVF (INVERTER) Put the cabin between floors, in order to make adjustments separately from landing doors. 2. Put the door middle opened, after switching off the unit (switch 57). 3. Disconnect the signals coming from the main controller (8, 9, 10, 11, 12 & 21, 23, 25). 4. Programm in 2 INPUTS and MASTER (Microswitches 1 in OFF and 4 in ON) independently to how you will program the doors afterwards. Microswitches 2 and 3 according to the kind of door. (Right-Left-Central sense and semiautomatic or automatic landing door). 5. Adjust the 3 potentiometers (52, 53, 54) in maximum, in order to overcome little mechanical disorders. 6. Switch on the unit by means the main switch (57). 7. The door must remain stopped. If the door moves check the micro switch 1 in OFF position. 8. Press the AUTO ADJUSTMENT button (51) to make an auto adjustment cycle. Α. The door should close. In case it opens you should check the micro switch 3 and if it is correct then any motor phases is inverted and it will have to interchange 2 of them and make the auto adjustment again. If the door doesn t move, check the motor wires and the motor connector (56). If the door stops before closing completely, the information from the encoder is not correct. Check the encoder (55) and try the auto adjustment again. If the door stops in the locking skate movement, check manually if the locking and de-locking skate movement is made easily and completely. (See the Mounting cabin doors instructions). If the door doesn t close completely disconnect the VVVF and check if there is any mechanical obstruction. B. Once the door is fully closed it will activate the CLOSE led and after a few seconds will open slowly and the led will be deactivated. The door should open slowly until the mechanical rubber stopper. If it only opens 26cm, the encoder information doesn t arrive to the VVVF. Check the connections or change the encoder or the wire if they are damaged. If it doesn t open completely, check the mechanical because the motor torque is enough to drag any kind of door (Check the wheels, the leaves, e.t.c.) C. The door will close again without hitting. If the door doesn t close, one encoder phase fails. Verify the wire and the encoder. If the door stops for some seconds before the close movement there is too much mechanical friction detected by the system. The system will work, but the door operator should be checked mechanically. If the door closes hitting, check the microswitch No.2 (type of landing door). At this point by pressing TEST button the door will make a closing or opening movement. It should open and close without hitting with the standard movements pre-programmed. So now it is the time to adjust the speeds (52 and 53). D. Be sure that the 3 movements (CLOSE-OPEN-CLOSE) are well completed when running the autoadjustment function. Check all the functions: obstruction, photocell, the inputs, open/close movements, etc. E. If the VVVF control works correctly, we can switch off the circuit and program according to your requirements and connect the input signals from the manoeuvre lift control.

21 42 POSSIBLE PROBLEMS & SOLUTIONS The door doesn t answer to the test or auto-adjustment buttons. Switch OFF (57) and try again. The door only closes 35cm. This is the clear entrance of any controller that has never been adjusted. Therefore an auto adjustment is required. The door opens but doesn t close. Check if the photocell LED is activated. Check if the close signal arrives to the system using a multimeter or the console. Check if the re-opening signal is activated. Check that there is no stray voltage in the open signal. The door re-opens by itself. Check the sensibility of the re-opening (# 54) Safety regulation potentiometer. Check that the photocell is not activated. Check that there is no mechanical obstruction on the door. In case of having the same problem, disconnect the photocell and try again with the TEST button, and if the door doesn t open totally there must be a mechanical obstruction on the door. The photocell is activated intermittently. Check the grounding connection (#6). Check the correct plugs connection. Remove the photocell wiring from any place where there are electric noises such as motors, supplies wiring, etc. If you can use a console, please check the stability of the signal. Do not extend the wires especially the reception one (green colour). Take in mind that in master mode the system recognizes automatically the photocell detector after making a complete open - close cycle with the beam free controlled by the input signals. The door doesn t reach the fully open position. The mechanical adjustment of the door is not correct, as the motor of the door operator has always enough power to open in normal circumstances. The door reopens when the skate is closing. Check the regulation of the skate, because probably the locking system of the skate is not well adjusted and the door has a mechanical friction, and consequently the door reopens and the obstruction LED lights. The door hits when it opens. Check that the skate un-locking is well fixed before the door starts to open. In case the skate is not fully fixed you should check the skate adjustment because it is probably too hard. The ON LED is activated and the door doesn t obey to the signals. There has been an obstruction at opening and then the door enters into an out of order stage during 15 seconds. There is a continuous obstruction and the lift controller has not changed the close signal by the open signal in slave mode. There has been a short circuit in the output of the motor, and the system will be deactivated during 3 seconds. The door hits when is fully opened, the open LED is not activated and the system gets out of order. Check the tension of the toothed belt, because probably it is not correctly adjusted and it slips on the pulley of the motor and consequently the encoder is sending a wrong information. The system gets power but doesn t work and the led ON is off. Check if the external fuse is burned and change it for another of the same type (250V, 4A ceramic fast speed).

22 43 The LEDS are working but the door doesn t move. The power module (and the internal fuse related) is blown and the controller must be sent back to be repaired. Do not try to change it by yourself as it could give an electric shock and damage more components. The motor is moving intermittently. Check the wiring connections or if a phase of the motor is falling. The door opens less centimeters in each movement and the opened led is activated, but the door is not really opened. If the motor box protection has been de-mounted, be sure that the encoder wire is free inside the box. Maybe the wire is pressed between the motor and a plastic nerve and the encoder information does not arrive properly to the VVVF. How to check the correct direction of rotation of the motor. Disconnect the input signals from the controller, the encoder wires and program the switch 1 in ON position. (Only mains supply and motor connected). Switch on the circuit. If the door starts to open, then the turning sense is correct, but if the door starts to close, interchange two motor phases. Connect the encoder wire and the system inputs. How to check the encoder If the door opens 26cm only, the encoder information doesn t arrive to the VVVF. Check the connections or the wires if they are damaged or change the encoder. If during the start up, the door opens completely (after closing), it remains opened, although the CLOSED led is activated, a phase of the encoder is failing and we have to interchange the two central wires. Even if after the above the door doesn t work properly, change the encoder. PREVENTIVE MAINTENANCE FOR CABIN DOORS VVVF 1. Check and replace the electric contact as necessary. (Approximately after 2 million cycles). 2. Periodically check that the closing cycle ends resting on the rubber stop. 3. Concentric and eccentric wheels require no maintenance. Replace them when they have signs of wear, noisy operation... (Approx. after 10 million cycles). 4. To prolong the life of the hanger wheels keep the top tracks clean. Never apply grease to the top tracks. 5. Once a year grease the shafts of the skate. Use only SAE-20 lubricants (Do not use spray lubricants). 6. Replace the guide shoes when they appear to be worn. 7. Periodically check the tension of the belt. With the correct tension the life of the belt is almost unlimited. 8. Once a year grease the shaft of return splined pulley (Do not use spray lubricants). 9. Periodically check and adjust the tension of the air cords. Replace them when they have signs of breaks, wear... (approximately after 6 million cycles). 10. Synchronization wheels (air cord pulleys) need no maintenance. Replace them when the have signs of wear, cracks or noisy operation... (approx. 8 million cycles).

23

24

25 Βιομηχανική Περιοχή Κιλκίς, Ελλάδα Τηλ: Fax: Kilkis Industrial Area, Greece Tel: Fax:

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + 8 CABIN DOORS DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any

More information

FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL

FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL *ACMAP1* ACMAP1 INS-TEC-GC-40.02 V1 Rev.: 11.2005 INDEX PACKAGING CONTENT...3 TECHNICAL DRAWING...3 OPERATOR ASSEMBLY INTO THE CABIN DOOR...4 SILL ASSEMBLY...4

More information

AUTOMATIC DOORS FOR LIFTS

AUTOMATIC DOORS FOR LIFTS ENG Installation manual. Automatic folding car door. Model: Electronic Driven ECC 230 V. MAN-MMEC00000ENGTC-07.2015 INDEX TECHNICAL DRAWING... 3 PACKAGING CONTENT... 4 OPERATOR ASSEMBLY INTO THE CABIN

More information

AUTOMATIC DOORS FOR LIFTS MODEL ECC FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL

AUTOMATIC DOORS FOR LIFTS MODEL ECC FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL MODEL ECC FOLDING DOOR ASSEMBLY AND MAINTENANCE MANUAL *MANMMPLINGDCTL* MAN-MMPLINGDCTL Rev.: 04.2009 INDEX PACKAGING CONTENT...3 TECHNICAL DRAWING...3 OPERATOR ASSEMBLY INTO THE CABIN DOOR...4 SILL ASSEMBLY...4

More information

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

SLIDING DOOR OPERATOR INSTRUCTION MANUAL SLIDING DOOR OPERATOR INSTRUCTION MANUAL (MODEL NO. 1071.101 & 1071.102) Please carefully keep this manual for good maintenance. Caution Be sure the door opener is far away from moisture, vibration, and

More information

TEL: G&C Electronics CC E. T.

TEL: G&C Electronics CC E. T. TEL: +27 21 448 6774 G&C Electronics CC FAX: +27 21 447 7794 E. T. CK 89/31531/23 E-mail : etsystems@icon.co.za Internet: www.et.co.za 15 Nelson Road P.O. Box 34524 Observatory Groote Schuur Cape Town

More information

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind) Barrier Gate Manual (DZX2. Control Board) (The third version) (Pictures for reference only, the product prevail in kind) Contents. Brief Introduction... 2. Functions and Features... 3. Technical Data...2

More information

Roll Up Door Operator

Roll Up Door Operator INSTRUCTIONS & OWNERS MANUAL Roll Up Door Operator 2 INDEX Preparation before installation 4. Terms and definitions 5. Pictures & names of parts 6. Mounting the weight bar 7. Installing the operator 7.

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual Sliding Gate Operator User's Manual PY800AC/PY00AC. Products introduction Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

GLOBAL LIFT EQUIPMENT LTD. Fermator Door Spares

GLOBAL LIFT EQUIPMENT LTD. Fermator Door Spares Fermator Door Spares Units H42/43 Ashmount Enterprise Park, Flint, Flintshire, CH6 5YL. Tel: 01352 735400 Fax: 01352 735733 Email: sales@global-lift.com www.global-lift.com Tel: 01352 735400 Fax: 01352

More information

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual Sliding Gate Operator User's Manual SL600AC. Products introduction Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button interface.

More information

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max. Automated system for NEW Passage opening 700-3.000 mm Max. leaf weight 110-2x70 Kg FAAC SERIES automated systems are intended for the automation of exits in compliance with European Standard EN16005; in

More information

Servo and Proportional Valves

Servo and Proportional Valves Servo and Proportional Valves Servo and proportional valves are used to precisely control the position or speed of an actuator. The valves are different internally but perform the same function. A servo

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

ELECTRIC MACHINES EUROLAB 0.3 kw

ELECTRIC MACHINES EUROLAB 0.3 kw index SINGLE-PHASE MOTORS SPLIT-PHASE MOTOR DL 30130 CAPACITOR MOTOR DL 30140 UNIVERSAL MOTOR DL 30150 REPULSION MOTOR DL 30170 THREE PHASE ASYNCHRONOUS MOTORS SQUIRREL CAGE THREE PHASE ASYNCHRONOUS MOTOR

More information

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3 Operating Instructions for DORNIER looms Robustness Reliability Quality Productivity Versatility WARNING! - Condensation could form on the Weft Feeder when

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 9-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Setup and Programming Manual

Setup and Programming Manual Microprocessor and Handy Terminal Setup and Programming Manual Versions U04 to U19 for Sliding Door Systems P/N 159000 Rev 7-2-07 The manufacturer, NABCO Entrances, Inc. suggests that this manual be given

More information

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i OPERATING MANUAL Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i Art. nr. 40200801 WHISPER POWER BV ENGLISH: PAGE 1 Kelvinlaan 82 9207 JB Drachten NEDERLANDS: PAGINA 41 Netherlands

More information

PY600AC Sliding Gate Opener User Manual

PY600AC Sliding Gate Opener User Manual PY600AC Sliding Gate Opener User Manual 2017 Dear users, Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 1. INTRODUCTION 2. SAFETY INSTRUCTIONS 3. SPECIFICATION 4. OPERATING INSTRUCTIONS AND CONTROL FUNCTIONS 5. SET UP PROCEDURE 6. CONNECTIONS

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

1. An inverter can be programmed to stop an AC motor quickly by enabling

1. An inverter can be programmed to stop an AC motor quickly by enabling Student ID: 53703105 Exam: 086053 - Controlling Industrial Motors When you have completed your exam and reviewed your answers, click Submit Exam. Answers will not be recorded until you hit Submit Exam.

More information

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş. 1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.

More information

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş. 1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.

More information

Automatic Swing door Operator SD3108 Product manual. Notes: please keep the manual properly for reference. Do carefully read this manual before use.

Automatic Swing door Operator SD3108 Product manual. Notes: please keep the manual properly for reference. Do carefully read this manual before use. Automatic Swing door Operator SD3108 Product manual Notes: please keep the manual properly for reference. Do carefully read this manual before use. Safety Warning! Please read carefully the instructions

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns 24-488 and 24-489 Control must be connected to a known GOOD LOAD prior to testing Problem: No output from the control

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

ROBUSTA PM HD Automatic horizontal sliding car door Designed for high traffic intallations

ROBUSTA PM HD Automatic horizontal sliding car door Designed for high traffic intallations ROBUSTA PM HD Automatic horizontal sliding car door Designed for high traffic intallations Commercial Service lifts DOC-FECMCBPRHC00EN ONGOING VERSION: 07-03-2014 Door configuration LIFT APPLICATION Door

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8

More information

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

F ERNI K I T THE FERNI-S KIT CONSISTS OF: CAME UNITED KINGDOM LTD ORCHARD PARK INDUSTRIAL ESTATE TOWN STREET, SANDIACRE, NOTTINGHAM, NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 INTERNET - www.cameuk.com E-MAIL - enquiries@cameuk.com TECHNICAL

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual for M² Sync Slideout Control Box #1510000122 CONTENTS Introduction Installation Installation Problems Program Mode Operation Mode Preventative Maintenance Fault Diagnostics

More information

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING Sliding Gate Opener Model: DKC400Y Installation Manual WARNING Read and thoroughly understand all instructions before installing or operating this automatic gate opener. Failure to do so may cause serious

More information

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection.

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection. GeN2 Comfort lift A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection. Using a unique polyurethane-coated steel belt drive system - a revolutionary

More information

KONE High-Performance Door Systems

KONE High-Performance Door Systems PRECISE, SOLID, FAST AND QUIET EVERY TIME. KONE High-Performance Door Systems People judge the performance of an elevator by how well its doors work. Doors that function improperly can create a negative

More information

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF: CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

Installation and Maintenancee Manual

Installation and Maintenancee Manual Installation and Maintenancee Manual Commercial Boom Gate Operator Model: GDS BOOM 4 and 6 A.B.N. 62 059 806 405 Nov 2013 Section No: CONTENTS Page Number: 1 Safety Precautions 3 2 Specifications 4 3 Mechanical

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL TABLE OF CONTENTS SYSTEM...... Warning........ Description...... Prior to Operation OPERATION... Main Components... Mechanical...

More information

SECEUROGLIDE ROLLER GARAGE DOORS, SECEUROSHIELD, SECEUROSCREEN & SECEUROVISION ROLLER SHUTTERS CONTENTS

SECEUROGLIDE ROLLER GARAGE DOORS, SECEUROSHIELD, SECEUROSCREEN & SECEUROVISION ROLLER SHUTTERS CONTENTS Operating & Maintenance Instructions SECEUROGLIDE ROLLER GARAGE DOORS, July 2007 Issue 4 SECEUROSHIELD, SECEUROSCREEN & SECEUROVISION ROLLER SHUTTERS CONTENTS Page 1. General Instructions 2 2. Operating

More information

Model 2300DL Installation Guide

Model 2300DL Installation Guide Model 2300DL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300DL

More information

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box Installation & Service Manual M² Sync Room Slideout System w/o Room Locks: for Slideout Control Box# 1510000143 and 1510000198 Figure 1 01/13 Power Gear #3010002088 Rev. 0C Installation and Service Manual

More information

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT Quadri di Manovra per Ascensori Lifts Control Panels PELAZZA PEPPINO S.r.l. 20063 CERNUSCO SUL NAVIGLIO (MI) ITALY Via Ponchielli, 6/8 Tel. 02/92.31.694 Fax 02/92.42.706 Tel. 02/92.42.706 Web Site: www.pelazza.com

More information

TROUBLESHOOTING TP. Index

TROUBLESHOOTING TP. Index TROUBLESHOOTING TP Index E1 POWER CUT DETECTED... 2 E2 LOCK ERROR... 3 E3 DRAINAGE FAILURE / WATER IN TUB... 6 E4 MAXIMUM WATER LEVEL REACHED... 6 E5 FAULT WATER INLET... 6 E6 HEATING FAULT... 6 E7 MAXIMUM

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

Installation Manual DELT. Platform stairlift. Web: Tel: Mobile:

Installation Manual DELT. Platform stairlift. Web:   Tel: Mobile: Installation Manual DELT Platform stairlift Web: www.lehner-lifttechnik.at Tel: +4372783514 Email: office@lehnerlifttechnik.at Mobile: +436641612980 Table of content OBSERVE THE FOLLOWING POINTS BEFORE

More information

Magnetek DSD 412 Drive

Magnetek DSD 412 Drive DRIVE STARTUP MANUAL Magnetek DSD 412 Drive Induction Motor Installation www.smartrise.us 2601 Fair Oaks Blvd., Sacramento, CA 95864 916.457.5129 Magnetek DSD 412 Drive EQUIPMENT/SETTINGS VERIFICATION

More information

HIGH SPEED SLIDING GATE OPENER

HIGH SPEED SLIDING GATE OPENER HIGH SPEED SLIDING GATE OPENER Model: is1200 + Elsema s Eclipse Control Card with GDS Operator USER MANUAL CONTENTS Section No: Page No: 1 Safety Precautions 3 2 Wiring Requirements 4 3 Installation details

More information

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT. Z700-A82 / 120V Treadmill WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT. Table of Contents TABLE OF CONTENTS Table of Contents...1 Table of Figures...3 Description...4

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

6100 Series Swing Door Operator Installation Instructions

6100 Series Swing Door Operator Installation Instructions 6100 Series Swing Door Operator Installation Instructions The manufacturer s specifications for this product require the installation to be approved by an AAADM certified inspector. -USA 4324 Phil Hargett

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Table of Contents

Table of Contents Flexirun Self Repairing Rapid Roll Up Door Quick Assembling Guidebook Flexirun PLC Curtain Unwinding Detection Safety Edge Manualopen Basic or Easy 0161 432 6655 sales@indupart.co.uk /indupart /indupart

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS ASTRO ENVELOPE FEEDER AMC-2000-5 FOR RYOBI 3302 / ITEK 3985 (2 COLOR) INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Thank you for purchasing the Astro Envelope Feeder. It is fast, efficient, reliable,

More information

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT. Z100-A81 CE Treadmill WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT. Table of Contents TABLE OF CONTENTS Table of Contents...1 Table of Figures...3 Description...4

More information

SUNROOF - SERVICE INFORMATION ADJUSTMENTS

SUNROOF - SERVICE INFORMATION ADJUSTMENTS SUNROOF - SERVICE INFORMATION DESCRIPTION OPERATION DIAGNOSIS AND TESTING POWER TOP - SUNROOF SUNROOF ASSEMBLY-MODULE REMOVAL INSTALLATION CHANNEL-DRAIN REMOVAL INSTALLATION COVER-GUIDE MECHANISM REMOVAL

More information

JBI Docupunch P33 Automatic Punch

JBI Docupunch P33 Automatic Punch JBI Docupunch P33 Automatic Punch Instruction Manual Provided By http://www.mybinding.com http://www.mybindingblog.com TABLE OF CONTENTS SECTION I: INSTALLATION & TESTING: 1) Uncrating, Inspection & removal

More information

Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data

Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data Door Drive Unit The is an electrical door drive unit which automatically opens hinged lift doors up to 200 kg. As the operating arm is not directly fixed to the door, all landing doors in the lift can

More information

ESD5500E Series Speed Control Unit

ESD5500E Series Speed Control Unit ESD5500E Series Speed Control Unit 1 SPECIFICATIONS INTRODUCTION PERFORMANCE Isochronous Operation ± 0.25% or better Speed Range / Governor 1-7.5 KHz Continuous Speed Drift with Temperature ±1% Maximum

More information

MBM8 / MBM11- Barriers. Installer and User s manual

MBM8 / MBM11- Barriers. Installer and User s manual MBM8 / MBM11- Barriers Installer and User s manual v2.0 REV. 01/2014 00. CONTENT 01.SAFETY INSTRUCTIONS INDEX 00. CONTENT index page 01.A 01. SAFETY INSTRUCTIONS standards to follow page 01.B 02. PACKAGE

More information

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009 B00S - Super Swing Instruction Manual Document number: B00S-C Release: V4.0 Date: May 08,009 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must be familiar

More information

Der PARAVAN KALI V2 Cassette lift Owner`s Manual. User manual/ PARAVAN KALI V3.3 cassette lift (Software-Update 2.0)

Der PARAVAN KALI V2 Cassette lift Owner`s Manual. User manual/ PARAVAN KALI V3.3 cassette lift (Software-Update 2.0) Der PARAVAN KALI V2 Cassette lift Owner`s Manual User manual/ PARAVAN KALI V3.3 cassette lift (Software-Update 2.0) User manual for the PARAVAN KALI V2 cassette lift 1st Introduction The Paravan cassette

More information

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS Super ELF-X2 USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS SUPER ELF X2 WARNING! - Condensation could form on the Weft Feeder when it is moved from the cold environment of the warehouse to

More information

WWWAUTO-ROLLER.CO.ZA INSTALLATION MANUAL AUTO- ROLLER

WWWAUTO-ROLLER.CO.ZA INSTALLATION MANUAL AUTO- ROLLER WWWAUTO-ROLLER.CO.ZA INSTALLATION MANUAL AUTO- ROLLER Notice. Please read these instructions carefully before installing the Rolling Door motor 1. The motor must be installed and operated by a professional.

More information

Service Manual Gulf Stream Electronic Full Wall Slide Systems

Service Manual Gulf Stream Electronic Full Wall Slide Systems Service Manual Gulf Stream Electronic Full Wall Slide Systems CONTENTS Page Before you operate the slide system 2 Operating Instructions 3 Preventive maintenance 3 Manually overriding your slide system

More information

OPERATING INSTRUCTIONS IC-2, 3,4,5,6 INTELLICUT SERVO CUTTER Version 5.1xx Created 11/2009

OPERATING INSTRUCTIONS IC-2, 3,4,5,6 INTELLICUT SERVO CUTTER Version 5.1xx Created 11/2009 OPERATING INSTRUCTIONS IC-2, 3,4,5,6 INTELLICUT SERVO CUTTER Version 5.1xx Created 11/2009 "CAUTION" "DO NOT OPERATE MACHINE WITH GUARD REMOVED" UNCRATE AND INSPECT This machine has been carefully crated

More information

LIPPERTCOMPONENTS, INC.

LIPPERTCOMPONENTS, INC. LIPPERTCOMPONENTS, INC. SCHWINTEK INWALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL Contents I. Controls 1-1 System components 1 1-1A versions C1 & C2 2 1-2 Motor wiring harness connections 3 1-3 Extend

More information

Expanding Application of FRENIC-Lift Series for Elevators

Expanding Application of FRENIC-Lift Series for Elevators Expanding Application of FRENIC-Lift Series for Elevators Tetsuya Nomura Hiroyuki Yonezawa 1. Introduction In recent years the elevator industry has been transitioning from geared elevators that use standard

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

SMS PRODUCT CATALOGUE

SMS PRODUCT CATALOGUE SMS PRODUCT CATALOGUE CONTENTS 1 TAKEDO 3VF-NXP - LIFT INVERTER Page 3 2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER Page 6 3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT Page 7 4 HYDROVERT VVVF FOR

More information

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars. General In This Section PTC PTC-SCR PTC-AC PTC-MG VVMC-1000 SCR VFMC-1000 AC VVMC-1000 MG Traction Controllers, PTC, VVMC, VFMC General Systems described in this section can be used for geared traction

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 3500ETL/3600ETL Commercial Swing Gate Operator INSTALLATION MANUAL 01/08 CONTENTS IMPORTANT SAFETY INSTRUCTIONS. 3 Applications... 4 Pre-Installation Checklist... 5 Parts

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

Contents. Section 2: Electrical - Switches, Solenoids and Motors

Contents. Section 2: Electrical - Switches, Solenoids and Motors Contents Section 2: Electrical - Switches, Solenoids and Motors... 2-3 Switches...2-3 Switches A, B, C and D...2-4 Error Code A Switch...2-4 Error Code B Switch...2-5 Error Code C Switch...2-5 Error Code

More information

Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, IMPORTANT!

Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, IMPORTANT! MANUFACTURER INFORMATION: Name: ACORN Inc. Address: 6450 Kingspointe Parkway, Unit 1, Orlando, Florida, 32819 Helpline: 407 650-0216 IMPORTANT! READ THESE PROCEDURES THOROUGHLY PRIOR TO stair lift INSTALLATION

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

8. Remote Control Panel P4 Control

8. Remote Control Panel P4 Control 8. Remote Control Panel P4 Control Art Nr. 0000522 Bez. Remote Control Panel P4 Control Tabelle 1: Dokument Hardware Software Aktuell: R03 V1.00 -------------------------- Ersetzt: R02.1 V1.00 --------------------------

More information

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen. Kelly HSR Opto-Isolated Series Motor Controller with Regen User s Manual HSR72601 HSR72801 HSR12401 HSR12601 HSR12901 HSR14301 HSR14501 HSR14701 Rev.3.3 Dec. 2011 Contents Chapter 1 Introduction... 2 1.1

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

GENERAL SAFETY... 3 PARTS LIST...

GENERAL SAFETY... 3 PARTS LIST... Rev 17a 1 GENERAL SAFETY... 3 PARTS LIST... 4 GTR100... 4 GTR058... 5 TECHNICAL SPECIFICATIONS... 6 FEATURES:... 6 QUICK INSTALLATION GUIDE... 7 GATE ARM INSTALLATION... 8 BEFORE YOU START... 8 INSTALLATION

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual G-Scale Graphics 4118 Clayton Ct. Fort Collins, CO 80525 970-581-3567 GScaleGraphics@comcast.net www.gscalegraphics.net Revision C: Updated 7/15/2009 Page Overview The

More information

Z TECHNICAL INSTRUCTIONS

Z TECHNICAL INSTRUCTIONS ÍNDICE: Z40 2.0 TECHNICAL INSTRUCTIONS 1.- Error list 2.- Replace the control board 3.- Opening the machine 4.- Replace the power board 5.- Dismantling motor and gear box 6.- Assembly of gear box 7.- Pushing

More information

G203V / G213V MANUAL STEP MOTOR DRIVE

G203V / G213V MANUAL STEP MOTOR DRIVE G203V / G213V MANUAL STEP MOTOR DRIVE PRODUCT DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 80 VDC Motor Current 0 7 A Power Dissipation 1 13 W Short Circuit Trip 10

More information

User Instructions for WRC1021D. Doc

User Instructions for WRC1021D. Doc User Instructions for WRC1021D Doc. 0001-5989 CONTENTS 1.0 INTRODUCTION TO THE WRC1021D... 2 2.0 FUNCTIONAL DESCRIPTION... 3 3.0 POTENTIOMETERS, SWITCHES AND INDICATORS... 5 4.0 CALIBRATION AND START-UP

More information

MBM6 - Barrier. Installer and User s manual

MBM6 - Barrier. Installer and User s manual MBM6 - Barrier Installer and User s manual v2.0 REV. 11/2013 00. CONTENT 01. SAFETY INSTRUCTIONS INDEX 00. CONTENT index pág 01.A 01. SAFETY INSTRUCTIONS standards to follow pág 01.B 02. PACKAGE inside

More information

Model 2300JL Installation Guide

Model 2300JL Installation Guide Model 2300JL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300JL

More information

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box Installation & Service Manual M² Sync Room Slideout System w/o Room Locks: for Slideout Control Box# 1510000143 and 1510000198 Figure 1 01/13 Power Gear #3010002088 Rev. 0C Installation and Service Manual

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

G213V STEP MOTOR DRIVE REV 7: March 25, 2011

G213V STEP MOTOR DRIVE REV 7: March 25, 2011 Thank you for purchasing the G213V drive. The G213V is part of Geckodrive s new generation of CPLD-based microstep drives. It has short-circuit protection for the motor outputs, over-voltage and under-voltage

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information