PRODUCT CATALOG. Powered by ELECTRONET

Size: px
Start display at page:

Download "PRODUCT CATALOG. Powered by ELECTRONET"

Transcription

1 PRODUCT CATALOG

2 Flow Meters

3 Magnetic Flow Meters

4 ELMAG- 60H ELECTRO NET MAGNETIC FLOW METER ELMAG 60H DESCRIPTION The ELMAG-60H is a micro-controller based 2 wire full bore type electromagnetic flow transmitters specially used for various industrial applications. These flow transmitters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the flow transmitter is an obstruction- less & maintenancefree instrument in place of conventional mechanical flow measuring device. The use of Pulsed DC technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 ma DC inearly proportional to volumetric flow, The instrument is based on Faraday s law of electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity & corresponding electrical output is provided with respect to easuring voltage. SALIENT FEATURES Full bore type Suitable for conductive liquids 2 wire system with HART communication Material option depending upon process data Empty pipe indication Local Indication through Graphics LCD Maintenance free Simple & cost effective construction Inbuilt Data Logger DIMENSIONAL DETAILS FD Fig. Front View Line Size Flange Diameter D Diameter of Raised Face R Diameter of Bolt Hole Circle DBC Diameter of Bolt Hole No. of Holes Flange Distance FD Flow Range(m 3 /hr) at 0.03m/s to 6m/s Inch NB Minimum Maximum ½ / ½ ½ R Ø DBC Lining Ø Bolt Hole Note For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to D 1 Fig. Side View

5 MAGNETIC FLOW METER ELMAG 60H TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Power Supply Power Consumption Response Time Electronics Transmitter Enclosure Process Connections Mounting Operating Conditions Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 600 NB Pulsed DC coil 4 to 20mA DC, 2 wire HART COG Graphic LCD display - 5 digit for Flow Rate & 8 digit for Totalizer Flow As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% M.V.(For 20 to 100% flow) +/- 0.5% of M.V. +/- 0.2% of M.V. +/- 0.1% per C 85 C max for Rubber Lining & 220 C for PTFE Lining 10 kg/cm² max (higher on request) Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE Flange - MS / CS / SS316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum Coil Housing - MS / SS 304 / SS V DC < 40mW <10 Sec Integral / Remote Electronics IP66, Flow Tube IP68 ASA150 flanged, as per table B 16.5 (Other On Requirement) In-Line Horizontal / Vertical Temperature -20 to 75 C / Humidity 5 to 95% non condensing Note - For process conditions other than above please consult factory. ORDERING INFORMATION 15NB To 600NB 08 Other 05 PTFE 02 Remote 02 SS Hard Rubber 01 Local 01 Aluminum 01 Neoprene Rubber Lining Enclosure Material 04 PFA 04 Tantalum 03 EPDM 03 Platinum 02 SS Other 02 SS Hyst. C mA + HART 09 10mtr 01 MS / CS 01 ASA MS 01 SS 316L mA 01 5mtr Series Line Size Electronics Electronic Flange Flange Coil Electrode Output Remote Material Rating Housing Material Cable Length ELMAG 60H A 15NB B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01 * Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. * GSM output is without SIM card & SCADA viewing software. * For better accuracy consult factory. * Accuracy defined at lab conditions. 2

6 INSERTION TYPE ELECTROMAGNETIC FLOW METER ELMAG-100 SALIENT FEATURES Suitable for conductive liquid Maintenance free Insertion Type Local Indication through LCD Simple & cost effective construction Unit conversion facility Material option depending upon process data Universal Power Supply 90 to 260V AC Optional 24V DC Communication port (Optional) DESCRIPTION The ELMAG-100 is a micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device.the use of Pulsed DC technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20mA DC linearly proportional to volumetric flow. The instrument is based on Faraday s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid following through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range. TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Display Calibration Range Accuracy Linearity Repeatability Process Temperature Process Pressure Material of construction Power Supply Power Consumption Response Time Temperature Coef cient Process Connections Mounting Operating Conditions Transmitter Enclosure Liquids (Conductive) > 5 µs/cm 200 cp max 200 NB to 2000 NB Pulsed DC 1) 4 to 20 ma DC 2) Pulse 16 x 2 LCD - 4 digit for Flow Rate & 8 digit for Totalised Flow As per requirement (Factory Calibrated up to 4NB) +/- 2% of F. S. (for 20 to 100% ow) +/- 0.5% of F. S. +/- 1% of F. S. 85 ºC max. 10 kg/cm 2 max Electrode - SS 316L Retractable Assembly - MS / SS 304 Wetted Parts - SS 316 Option 1 24 V DC Option V AC, 50 Hz < 10 VA < 1 Sec +/- 0.01% per ºC ASA 150, 2 Flanged, as per table B 16.5 Insertion type Temperature 0 to 55 ºC / Humidity 5 to 95% non condensing Die Cast Aluminium IP 68 3 OPTIONAL Communication Port Remote Electronics RS 485 supporting MODBUS RTU Protocol GSM connectivity Weather-proof, IP-65, wall mounted

7 ELECTROMAGNETIC FLOW METER ELMAG-200E INSERTION TYPE ELECTROMAGNETIC FLOW METER ELMAG-100 DIMENSIONAL DETAILS M20 x 1.5,DOUBLE COMPRESSION CABLE ENTRY 120 mm 90 mm Adjustable 1000mm 290mm 5 mm GASKET NEOPRENE 100mm 200 mm P P ELMAG- 100 CMRI CERTIFIED DIE CAST ALUMINIUM FLAMEPROOF HOUSING 2 SS FLANGE ASA 150 B mm 15 mm 120 mm 26.5 mm 2 SS FLANGE ASA 150 B mm 49 mm 1&1/2 Ball Valve 2 SS FLANGE ASA 150 B mm 47mm Line Size (mm) Flow min (m/ 3 hr) Flow normal (m/ 3 hr) Flow max (m/ 3 hr) Flow (MLD) FLOW INLET Line Size/ mm LINE SIZE 200NB to 2000NB FLOW OUTLET Note Typical mounting dimensions for reference Standard factory calibration for 0 to 2m/Sec velocity ORDERING INFORMATION 200 mm to 2000 mm 04 All mA 09 None mtr. + HART Pulse R Remote 02 SS V AC 03 GSM mtr. 09 None 02 SS mA L Local 01 Aluminium ma 01 24V DC 02 RS mtr. 01 Data logger 01 MS SERIES Line Size Electronics Electronics Enclosure Output Power Supply Communication Port Remote Cable Length Data Logging Retractable Sensor Assembly ELMAG mm L / R E 01 F 01 G 02 H 02 I 02 J 01 K 02 *Due to our continuous product revisions, Design, Speci cations and Model Number are subject to change without notice. *Accuracy de ned at lab conditions. Note GSM output is without SIM card & SCADA viewing software. 4

8 EL E M LM A A G G MH ELEECLETCRTORMOAMGAGNNEETTICC FLOOWWMMETEETRER NO ELECTROMAGNETIC FLOW METER ELMAG 200 SALIENT FEATURES Suitable for conductive liquids Maintenance free Full bore type Local Indication through LCD Simple & cost effective construction Empty pipe indication Material option depending upon process data Universal Power Supply 90 to 260V AC Optional 24V DC Communication port (Optional) HART Communication DESCRIPTION The ELMAG-200 is a micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device. The use of Pulsed DC technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20mA DC linearly proportional to volumetric flow. The instrument is based on Faraday s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid following through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range. DIMENSIONAL DETAILS 250 mm H P P MODE L SR. W FD Meter OD W H FD Flow Range (m³ /hr) Size (mm) (mm) (mm) (mm) Min Normal Max 15 NB NB NB NB NB NB NB NB NB NB NB NB NB NB NB NB NB NB NB OD Flange Diameter H Coil Housing Height W Coil Housing width FD Flange to Flange distance 5 OD

9 ELECTROMAGNETIC FLOW METER ELMAG 200 TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Display Engineering Unit Calibration Range Accuracy Linearity Repeatability Temperature Coef cient Process Temperature Process Pressure Material of construction Power Supply Power Consumption Isolation Response Time Transmitter Enclosure Process Connections Mounting Operating Conditions Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 600 NB Pulsed DC 1) 4 to 20 ma DC, Isolated, HART 2) Pulse 16 x 2 LCD - 4 digit for Flow Rate & 8 digit for Totalised Flow User Programmable (m³ /hr by default) As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% of F. S. (for 20 to 100% ow) +/- 0.5% of F. S. +/- 0.2% of F. S. +/- 0.05% per C 85 C max for Rubber Lining & 120 C for PTFE Lining 10 kg/cm² max (higher on request) Lining - Rubber (5mm +/-1mm thick) / PTFE (Te on) (3mm +/-1mm thick) Flange - CS / MS / SS Electrode - SS 316L / Hastalloy C / Platinum Coil Housing - MS / SS 304 Option 1 24 V DC Option V AC, 50 Hz < 10 VA 1.4 KV between Input, Output & Power Supply < 1 Sec Die cast Aluminium IP 66, ow tube IP 68 ASA 150 anged, as per table B 16.5 In-Line Horizontal (Vertical on request) Temperature 0 to 55 C / Humidity 5 to 95% non condensing Note - For process conditions other than above please consult factory. OPTIONAL Communication Port 1) RS 485 supporting MODBUS RTU Protocol 2) GSM Communication 3) 4-20mA with HART Electronics Remote Electronics ORDERING INFORMATION 08 Other 04 All 4-20mA 08 Other 03 SS SS Platinum 03 + HART 09 None mtr. 15 mm to R Remote 02 Rubber L 4-20mA 02 SS SS Hyst C 02 SS Pulse V AC 02 GSM mtr. 600 mm Local 01 PTFE 01 CS / MS 01 MS 01 SS 316L 01 Aluminium ma 01 24V DC 01 RS mtr. SERIES Line Size Electronics Lining Flange Coil Electrode Electronics Power Output Communi- Remote Material Housing Material Enclosure Supply cation Port Cable Length ELMAG mm L / R A 02 B 01 C 01 D 01 E 01 F 01 G 02 H 01 I None 01 Datalogger Data logging J 02 6 *Due to our continuous product revisions, Design, Speci cations and Model Number are subject to change without notice. *Accuracy de ned at lab conditions. Note GSM output is without SIM card & SCADA viewing software. Consult Factory

10 BATTERY POWERED ELECTROMAGNETIC FLOW METER ELMAG-600 SALIENT FEATURES Full bore type Suitable for conductive liquid Battery Operated Data Logging facility for 5 Years Local Indication through Graphics LCD Communication port (Optional) Empty pipe indication(optional) Maintenance free Simple & cost effective construction Inbuilt Data Logger DESCRIPTION The ELMAG-600, is a battery-powered Electromagnetic flow meters are ideal when connecting to a power is difficult or expensive. When no mains power is available, the battery powered ELMAG-600 gives the flexibility to install a reliable flow meter, virtually anywhere, without distorting accuracy & performance. ELMAG-600 is provided with 2 years continuous battery operation. The flow meter is extremely easy to use, simple to install & requires no regular maintenance. The product is engineered for various industrial as well as domestic applications such as Municipal & Industrial Water applications, Cooling tower, Water treatment, etc. The graphic display provides indication for flow rate & totalized flow with key selection. The display auto shuts off after 10 minutes, which saves the battery life. The display can be turned ON by pressing the 'enter' key. 7 TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Power Supply Low Bat indication Battery Life Response Time Transmitter Enclosure Process Connections Mounting Operating Conditions Data Logging Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 600 NB Pulsed DC COG Graphic LCD display- 5 digit for Flow Rate & 8 digit for Totalizer Flow As per requirement (Factory Calibrated ) +/- 0.5% of M.V. (for 20 to 100% flow) +/- 0.5% of M.V. +/- 0.2% of M.V. +/- 0.05% per C 85 C max for Rubber Lining & 220 C for PTFE Lining 10 kg/cm² max (higher on request) Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE Flange - MS /CS / S316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum Coil Housing - MS / SS 316 Inbuilt Battery 3.6 V, 19 Ah ( 2 nos) Provided 2 to 10 years depending on sampling time. <10 Sec Electronics IP66, Flow Tube IP68 ASA150 flanged, as per table B 16.5 (Other On Requirement) In-Line Horizontal / Vertical Temperature -20 to 75 C / Humidity 5 to 95% non condensing For 5 years (per day 1 sample) Note - For process conditions other than above please consult factory. OPTIONAL Communication Output 1) RS 232 2) GSM connectivity 3) Pulse

11 ELMAG 600 BATTERY POWERED ELECTROMAGNETIC FLOW METER ELMAG-600 DIMENSIONAL DETAILS R FD Fig. Front View D Fig. Side View ½ / ½ ½ Ø Bolt Hole Ø DBC Lining DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5) Line Size Flange Diameter D Diameter of Raised Face R Diameter of Bolt Hole Circle DBC Diameter of Bolt Hole No. of Holes Flange Distance FD Note For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to Flow Range(m 3 /hr) at 0.03m/s to 6m/s Inch NB Minimum Maximum Measuring error (% M.V) Flow Nomograph 1.0% 0.9% 0.8% 0.7% 0.6% 0.5% 0.4% 0.3% 0.2% 0.1% 0.0% Flow Velocity 6 m/s ORDERING INFORMATION 08 Other 05 PTFE 04 PFA 04 Tantalum 15NB To 600NB 02 Remote 02 SS Hard Rubber 01 Local 01 Aluminum 01 Neoprene Rubber Lining Enclosure Material 03 EPDM 03 Platinum 03 Pulse 02 SS Other 02 SS Hyst. C 02 GSM 02 10mtr 01 MS /CS 01 ASA MS 01 SS 316L 01 RS mtr Series Line Size Electronics Electronic Flange Flange Coil Electrode Comm. Material Rating Housing Material Output ELMAG 600 A 150NB B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01 Remote Cable Length * Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. * GSM output is without SIM card & SCADA viewing software. * For better accuracy consult factory. * Accuracy defined at lab conditions. 8

12 ELECTRONIC WATER METER ELMAG-600W SALIENT FEATURES Electronic replacement to mechanical water meter Battery Powered Real time data Reliable connectivity Durability Accurate measurement Zero maintenance Tampering protection Low pressure loss Simple installation Simple & cost effective construction DESCRIPTION The ELMAG-600W, battery-powered Electromagnetic water meters, are ideal when connecting to a power is difficult or expensive. When no mains power is available, the battery powered ELMAG-600W gives the flexibility to install a reliable flow meter, virtually anywhere, without distorting accuracy & performance. ELMAG-600W is provided with 2 years continuous battery operation. The water meter is extremely easy to use, simple to install & requires no regular maintenance. The product is engineered for various industrial as well as domestic applications such as Municipal & Industrial Water applications, Cooling tower, Water treatment, etc. The graphic display provides indication for flow rate & totalized flow with key selection. The display auto shuts off after 10 minutes, which saves the battery life. The display can be turned ON by pressing the 'enter' key. IT S AN ELECTRONIC WATER METER. TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Power Supply Low Bat indication Battery Life Response Time Transmitter Enclosure Process Connections Operating Conditions Data Logging Water > 5 µs/cm 200 cp max 15 NB to 40 NB Pulsed DC COG Graphical LCD display- 4 digit for Flow Rate & 6 digit for Totalizer Flow As per requirement (Factory Calibrated) +/- 1% of M.V. +/- 1% of M.V. +/- 0.5% of M.V. +/- 0.05% per C 65 ºC max 5 kg/cm² max Electrode - SS 316L Inbuilt Battery 3.6 V, 19 Ah Provided 2 to 10 years depending on sampling time. <10 Sec Die cast Aluminum IP66, flow tube IP68 BSP Threaded (F) Temperature -20 to 75 C / Humidity 5 to 95% non 25 O C For 5 years (per day 1 sample) OPTIONAL Communication Port 1) RS 232 for Data Downloading 2) Automatic Meter Reading (AMR- RF) / GSM 3) Pulse Note - For process conditions other than above please consult factory. 9

13 ELECTRONIC WATER METER ELMAG-600W DIMENSIONAL DETAILS H Mete r Size L (mm) D (mm) H (mm) Flow Range (m³ /hr) Min Normal Max 15 NB NB NB NB NB D Diameter H Height L Length L D Note Typical mounting dimensions for reference Standard factory calibration for 0.2 to 2 m/s velocity Max. flow range in LPH/LPM is upto 9999 ORDERING INFORMATION 05 40NB 04 32NB 03 25NB 03 Pulse (Open Collector) 02 20NB 02 AMR-GSM 01 15NB 01 RS232 SERIES ELMAG-600W Line Size Communicati on Output A 01 B 01 * Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. * For GSM communication, SIM card & SCADA viewing software will be in customers scope. * Accuracy defined at lab conditions. * For better accuracy consult factory. 10

14 TWO WIRE ELECTROMAGNETIC FLOW METER ELMAG-600H SALIENT FEATURES Full bore type Suitable for conductive liquids 2 wire system with HART communication Material option depending upon process data Empty pipe indication Local Indication through Graphics LCD Maintenance free Simple & cost effective construction Inbuilt Data Logger DESCRIPTION The ELMAG-60H is a micro-controller based 2 wire full bore type electromagnetic flow transmitters specially used for various industrial applications. These flow transmitters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the flow transmitter is an obstruction- less & maintenancefree instrument in place of conventional mechanical flow measuring device. The use of Pulsed DC technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 ma DC inearly proportional to volumetric flow, The instrument is based on Faraday s law of electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity & corresponding electrical output is provided with respect to easuring voltage. TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 600 NB Pulsed DC coil 4 to 20mA DC, 2 wire HART COG Graphic LCD display - 5 digit for Flow Rate & 8 digit for Totalizer Flow As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% M.V.(For 20 to 100% flow) +/- 0.5% of M.V. +/- 0.2% of M.V. +/- 0.1% per C 85 C max for Rubber Lining & 220 C for PTFE Lining 10 kg/cm² max (higher on request) Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE Flange - MS / CS / SS316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum Coil Housing - MS / SS 304 / SS V DC < 40mW <10 Sec Integral / Remote Electronics IP66, Flow Tube IP68 ASA150 flanged, as per table B 16.5 (Other On Requirement) In-Line Horizontal / Vertical Temperature -20 to 75 C / Humidity 5 to 95% non condensing Power Supply Power Consumption Response Time Electronics Transmitter Enclosure Process Connections Mounting Operating Conditions 11 Note - For process conditions other than above please consult factory.

15 ELMAG- 60H ELECTRO NET TWO WIRE ELECTROMAGNETIC FLOW METER ELMAG-600H DIMENSIONAL DETAILS FD Fig. Front View R D Fig. Side View Ø DBC Lining Ø Bolt Hole DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5) Line Size Flange Diameter of Diameter of Diameter No. Flange Flow Range(m 3 /hr) Diameter Raised Face Bolt Hole of Bolt of Distance at 0.03m/s to 6m/s Inch NB D R Circle DBC Hole Holes FD Minimum Maximum ½ / ½ ½ Note For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to Measuring error (% M.V) Flow Nomograph 1.0% 0.9% 0.8% 0.7% 0.6% 0.5% 0.4% 0.3% 0.2% 0.1% 0.0% m/s Flow Velocity ORDERING INFORMATION 15NB To 600NB 08 Other 05 PTFE 02 Remote 02 SS Hard Rubber 01 Local 01 Aluminum 01 Neoprene Rubber Lining Enclosure Material 04 PFA 04 Tantalum 03 EPDM 03 Platinum 02 SS Other 02 SS Hyst. C mA + HART 09 10mtr 01 MS / CS 01 ASA MS 01 SS 316L mA 01 5mtr Series Line Size Electronics Electronic Flange Flange Coil Electrode Output Remote Material Rating Housing Material Cable Length ELMAG 60H A 15NB B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01 *Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. *GSM output is without SIM card & SCADA viewing software. * For better accuracy consult factory. * Accuracy defined at lab conditions. 12

16 ELECTROMAGNETIC FLOW METER ELMAG-800 SALIENT FEATURES Suitable for conductive liquid Maintenance free Full bore type Simple & cost effective construction Power Supply 24V DC Supported by Flow view software DESCRIPTION The ELMAG-800 is a micro-controller based full bore type electromagnetic flow meters specially used for various industrial domestic applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device. The use of Pulsed DC technology offers highest ability & better measuring accuracy in the form of electrical signal in the form of RS 485 communication linearly proportional to volumetric flow. The instrument is based on Faraday s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range. TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Power Supply Power Consumption Isolation Response Time Transmitter Enclosure Process Connections Mounting Operating Conditions Communication Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 200 NB Pulsed DC RS 485 As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% of F. S.(for 20 to 100% flow) +/- 0.5% of F. S. +/- 0.2% of F. S. +/- 0.05% per C 85 C max for Rubber Lining 10 kg/cm² max (higher on request) Lining - Rubber (5mm +/-1mm thick) Flange - CS / MS Electrode - SS 316L Coil Housing - MS 24 V DC < 10 VA 1.4 KV between Input, Output & Power Supply < 1 Sec Die cast Aluminium IP-66, flow tube IP-68 ASA 150 flanged, as per table B 16.5 (other on request) In-Line (Horizontal OR Vertical) Temperature 0 to 55 C / Humidity 5 to 95% non condensing RS

17 ELMAG 800 MODEL ELECTROMAGNETIC FLOW METER ELMAG-800 DIMENSIONAL DETAILS H SR. NO W FD Met er Size OD (mm) W (mm) H (mm) FD (m m) Flow Range (m³ /hr) Min Normal Max 15 NB NB NB NB NB NB NB NB NB NB NB NB OD Flange Diameter H Coil Housing Height FLOW NOMOGRAPH W Coil Housing width FD Flange to Flange distance Note Typical mounting dimensions for reference Standard factory calibration for 0 to 2m/Sec velocity Max. Flow range in LPH / LPM is upto 9999 Flow meter should be selected with the help of Nomograph recommended full scale velocity ORDERING INFORMATION 15 mm to 200 mm SERIES ELMAG-800 Line Size 65 mm *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions. 14

18 ORIFICE FLOW METER DESCRIPTION The Orifice plate is the most common differential pressure flow primary element. It is based on proven technology has no moving parts and is suitable for high temperature and pressure applications. Orifice plates are recommended for clean liquids, gases and low velocity steam flows. Flow measurement using Orifice plates requires the accurate location of up stream and downstream pressure tappings. Various types of orifice carrier assemblies are available to suit a wide range of applications SALIENT FEATURES Orifice Design as per BS EN ISO 5167 Range of Orifice types 1) Concentric Square Edge 2) Quarter Circle 3) Segmental 4) Eccentric Non IBR and IBR certified Orifice assembly Availableinwidevarietyofmaterials Nomovingparts,simpleconstruction Maintenance-free TECHNICAL SPECIFICATIONS Service Line Size Type Ori ce Assembly Materials Liquid, Gas and Vapor Application ½ to 20 1) Concentric Square Edge 2) Quarter Circle 3) Segmental 4) Eccentric 1) Orifice plate with ANSI B16.36 Flange 2) Integral Orifice. 3) Carrier ring type SS316 Std.(Others on Request) TYPES OF ORIFICE 1. Square Edge For general applications in clean fluids - the most widely used design. Suitable for pipes up to 1000 mm diameter Concentric Square Edge 2. Quarter Circle Suitable for measurement of low Reynolds number flows in pipelines of diameter less than 750 mm. Quarter Circle Segmental Suitable for measurement for measurement of dirty fluids and 2 phase flow - allows passage of extraneous matter. Suitable for pipes up to 350mm 4. Eccentric Suitable for measurement of dirty fluids and 2 phase flow preferred to segmental pipelines of diameters less than 350 mm. Segmental Eccentric

19 ORIFICE FLOW METER ANSI B ORIFICE FLANGES Orifice Flanges are intended for use instead of standard pipe flanges when an orifice plate or flow nozzle must be installed. Pairs of pressure tappings are machined into the orifice flange, making separate orifice carriers or tappings in the pipe wall unnecessary. The range of orifice flanges covers all standard sizes and ranges, and all common flange materials. Flanges are available in socket weld or weld neck form, and are typically supplied with two ½ NPT tappings in each flange. Jacking screws to ensure ease of removal of the primary flow element are provided. Orifice flanges are supplied complete with bolting and gasket kits. INTEGRAL ORIFICE Typically consisting of a factory assembled section of pipe with an orifice plate mounted between two flanges near the center of the run, terminated with a flange at each end to connect to the process. Building the assembly in the factory allows us to control all the variables which can lead to inaccuracies which can arise if the system is assembled by untrained personnel on-site. Other advantages include reduced installation time; the completed section only needs to be bolted into the pre-prepared line. The complete assembly can be calibrated to provide the maximum accuracy. ANSI B ORIFICE FLANGE ASSEMBLY INTEGRAL ORIFICE PLATE ASSEMBLY ORIFICE MATERIAL 316 Stainless Steel Hastelloy C276 Hastelloy B3 Monel 400 Titanium Tantalum PTFEandPVDF. 16

20 Ultrasonic Meter

21 ULTRASONIC FLOW METER ASIONIC-400W SALIENT FEATURES DOMESTIC AMR ULTRASONIC FLOW METER ASIONIC 400W Ultrasonic transit time measurement Long Battery life RF Connectivity Meets OIML(R49) & MID standards Bidirectional flow measurement Inbuilt data logging TECHNICAL SPECIFICATIONS ASIONIC 400W is designed to measures the velocity of a fluid in a sealed pipeline fitted with transducers. This enables calculation of flow and volume based on time of flight principle. ASIONIC 400W is a static water meter which has no moving parts to avoid wear and tear. The electronic unit having inbuilt LCD display to continuously indicate and log / record the following parameters a. Flow rate b. Total volume c. Forward and reverse flow d. Battery status e. Unit of measurement f. Real time ASIONIC 400W is an integral and hermetically closed static water meter intended for the registration of cold and hot water consumption. ASIONIC 400W is constructed as a vacuum chamber of molded composite material. Thus, the electronics are fully protected against penetration of water. This means that the meter can, without problems, be placed in e.g. bathrooms, where it is sprayed with water daily, and it is also suitable for mounting in meter wells, which are frequently filled with water. The meter can and must only be opened by Oilog s authorized service center by means of special tools, if the meter has been opened, and seal have thus been broken, the meter is no longer valid for billing purpose. Furthermore, the factory guarantee no longer applies. The water meter is powered by an internal lithium battery with up to 10 years lifetime. the battery can be changed by one of the Oilog s authorized service center / personnel. 17

22 ULTRASONIC FLOW METER ASIONIC-400W Testing Pressure 16 Bar Nominal Pressure 10 Bar Minimum Pressure 0.1 Bar Pressure Loss < 0.63 Bar Media Temperature 0.1 to 60 OC Relative Humidity 100% Ambient Temperature 70 OC Max. mean temperature over 24 hours 55 OC Remote Reading Wireless M-Bus(incripted-protects personal data against unauthorized monitoring) Reprogramming / Downloading Store Data Through Optical Port using proprietary Water AMR software Data Storage Facility Up to 10 Years Battery life 10 Years RF Frequency MHz Available line sizes 15, 20, 25, 32, 40 NB MOC SS / ABS Process Connection BSP Threading(Male) ALARM Battery Low Alarm Meter Tamper Alarm Meter Open Alarm Meter Dry Alarm Reverse Flow Alarm Meter Overload Flow Alarm Meter Overload Pressure Alarm Continuous Zero Flow Alarm Leak / Continuous Flow Alarm Communication Signal / Indication ACCURACY The MPE for the upper flow rate zone (Q2 Q Q4) is ±2% for temperature from 0.1CO and ± 3% for temperature grater than 30OC.to 30CO, The MPE for the lower flow rate zone (Q1 Q Q2) is ±5% regardless of the temperature range. Q3 Indicating range (minimum values) 18 m³/h m³ Q

23 ULTRASONIC FLOW METER ASIONIC-400W DIMENSIONAL DETAILS H MODEL SR. NO D Meter Size L (mm) D Diameter H Height D (mm) H (mm) L Length Flow Range (m³ /hr) Min Normal Max 15 NB NB NB NB NB NB L Note Typical mounting dimensions for reference Standard factory calibration for 0 to 2m/Sec velocity Max. Flow range in LPH / LPM is upto 9999 ORDERING INFORMATION 15 mm to 50 mm 09 None 02 SS 03 GSM 01 CS / MS 02 RS 485 SERIES Line Size Flange Communication Port ASONIC mm A 01 B 02 *Due to our continuous product revisions, Design, Speci cations and Model Number are subject to change without notice. *Accuracy de ned at lab conditions & higher sampling rate. 19

24 ULTRASONIC FLOW METER ASIONIC-200 SALIENT FEATURES Ultrasonic measurement using transit time technology EMI / EMC Compliant Single / Dual / Quad beam technology for precise measurements Maintenance free Excellent long term stability & reliability Inline / Hot retractable sensor assembly Simple & cost effective construction Empty pipe indication Low start flow measuring capability to earn revenue from every drop of liquid delivered IP 68 Construction No pressure drop DESCRIPTION The Serie ASIONIC-200 is a micro-controller based full bore type Ultrasonic Flow Meter, specially used for various industrial applications. These flow meters accurately measures the flow rate of liquid in closed pipes. Due to its simple& rigid design, the flow meter is an obstruction-less & maintenance free instrument in place of conventional mechanical Flow measuring devices. The system is well suited to most environments. Programming of the flow meter is simple and can be accomplished with 4 keys available on instrument, It provides access to an extensive range of diagnostic information. Meter is manufactured in several flow meter consoles to meet the specific requirements of various applications. TECHNICAL SPECIFICATIONS Media Viscosity Line Size Display Calibration Range Acoustic Paths Sonically conductive liquids 200 cp maximum 50 NB to 2000 NB 6 digit for Flow Rate & 8 digit for Totalised Flow As per requirement (Factory Calibrated) Single, Dual & four path Accuracy* Line Size ±0.5% of MV ±1% of MV ±2% of MV 50 to 300NB Single path to 600NB Dual path Single path ---- Turbidity Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of Construction Power Supply Communication Port Analog Output Response Time Transmitter Enclosure Process Connections Operating Conditions Data logging Sensor Pair Sensor MOC Electronics 650 to 2000NB Four path Dual path Single path Smaller than 10,000ppm (mg/ltr) with a low level of air bubble content ± 0.5% of M.V. ± 0.2% of M.V. ± 0.05% per O C -20 O C to 85 O C maximum 15 kg/cm 2 maximum Flow tube - SS / MS / CS 1) 230V AC,50 Hz 2) 24V DC,+20%, -15% / 20 Watts Max. RS-485 MODBUS RTU 4-20 ma < 1Sec Die Cast Aluminum IP-66, flow tube IP-68 ANSI 150 flanged, as per table B 16.5 Temperature -20 to 75 O C / Humidity 5 to 95% non condensing for 10 years (per day 1 sample) As per requitement SS 316 1) Integral 2) Remote Note For process conditions other than above, please consult factory. 19

25 A S I ONIC 200 ELECTRON ET ASIONIC 200 ELECTRO NET ULTRASONIC FLOW METER ASIONIC-400W DIMENSIONAL DETAILS H A W Fig. 1 Front View DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5) Line Size Flange Diameter of Diameter of Diameter No. Flange Flow Range(m 3 /hr) Diameter Raised Face Bolt Hole of Bolt of Distance at 0.03m/s to 6m/s Inch NB D R Circle DBC Hole Holes FD Minimum Maximum ½ Note- Standard factory calibration for 0.2 to 2m/Sec velocity Typical mounting dimensions for reference Max. Flow range in LPH / LPM is up to For line size above 600NB consult factory for dimensions & flow range Fig. 2 Side View INSTALLATION DRAWING Valve Flow Out Flow In Pipe Support Pipe Support 5D 10D Valve Valve Pipe Support Pipe Support 19

26 ULTRASONIC FLOW METER ASIONIC-400W ORDERING INFORMATION NB NB mtr 03 Four 08 Other mtr 02 Remote 02 Dual 02 Fixed Inline 02 SS Other 02 SS mA + RS V DC 02 5 mtr NB 01 Local 01 Single 01 Hot retracta ble insertio n SERIES Line Size Electronics No. of paths Sensor Constructi on 01 MS 01 ASA Aluminum mA V AC 01 0 mtr Flow Tube Flange Rating Electronic s Enclosure Output Power Supply Remote Cable Length ASIONIC 200 A 01 B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01 *Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions. 19

27 AUTOMATIC METER READER AMR 600 SALIENT FEATURES Increased Meter Reading Efficiency Through High Performance AMR. Accurate meter reading collection. Leak, tamper, and reverse flow alarms. Highly reliable RF communication with data encryption facility. Innovative remote Walk By automated reading solution. Uploads.CSV file to PC from Handheld unit over USB. Frequent transmit mode. Local display of HHU for operator convenience. DESCRIPTION The AMR 600 offers Walk By automated reading solution for efficient data collection with fewer efforts. Integrated RF transmitter with our own water meters makes it even more reliable and Cost effective. Eliminates the need for physical access or visual inspection of water meters, allowing gathering data from meters located in paces that are not easily accessible. Also eliminates the errors were present in manual meter reading system. TECHNICAL SPECIFICATIONS RF frequency band Display Transmission Interval RF output power Reception sensitivity Modulation technique Flow Meter Parameter readings HHU data Output Handheld memory Size Handheld Power Supply RF Bit rate AMR OPERATING SCHEME 865 MHz 867 MHz 16 x 2 LCD 13 Sec 17 Sec +12 dbm Down to -107 dbm FSK (Phase Shift Keying) Meter ID, Total Flow count, Battery Low flag, Back Flow flag, Leak detection flag, Meter Tampering flag CSV file over USB 512 Kb (4000 Records), Expandable (Optional) 2.4 V AA cell batteries 25 kbps *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions & higher sampling rate. 20

28 Turbine Flow Meters

29 TWO WIRE TURBINE FLOW METER FL-100 SALIENT FEATURES 2 wire System Simple & cost effective construction Suitable for non conductive clear liquids. Local display as 8X1 LCD Durable & Versatile Easy maintenance Die Cast Aluminium IP-68 housing Remote display optionally available DESCRIPTION The FL-100 is a 2 wire turbine flow transmitter specially used for various industrial applications. The flowing media engages a vaned rotor causing it to rotate at an angular velocity proportional to flow rate. The pick-up coil senses the spinning motion of the rotor inside the pipe & converts it into a pulsating electrical signal. Summation of the pulsating electrical signal is directly related to the total flow. The frequency is linearly proportional to flow rate which is converted to electrical signal 4-20 ma. TECHNICAL SPECIFICATIONS Media Viscosity Line Size Display Transmitter Electronics Remote Electronics Cable Type of Output Calibration Range Accuracy Linearity Repeatability Pressure Drop Turn down ratio Process Temperature Process Pressure Material of construction Power Supply Power Consumption Response Time Temperature Coefficient Transmitter Enclosure Process Connections Liquids (Clear) 100 cp max 15 NB to 150 NB 8 x 1 LCD - 4 digit for flow rate & 8 digit for totalised flow (Flow rate & totalised flow will be visible through toggle key) Option 1 Integral Option 2 Remote 25 mtr max 1) 4 to 20 ma DC 2) Pulse - 30mA Peak-Peak As per requirement (Factory Calibrated) +/- 1% of F. S. (For 20 to 100% flow) +/- 1% +/- 1% Approx kg/cm 2 at max. Flow 10 1 to to 85 0 C max 0 to 10 kg/cm² max Bearings - Tungsten Carbide Sleeve / V Jewel Rotor - SS 410 / 17.4 PH Shaft - Tungsten Carbide Body / Support / Flange - SS 24 V DC < 0.5 VA < 100 msec +/- 0.01% per 0 C Die Cast Aluminum IP 68 1)ASA 150 RF,flanged as per table B ) BSP (M), Threaded ( Upto 50 NB only) 3)SS Tri-clover ( Upto 50 NB only) In-Line ( Horizontal or Vertical ) Temperature 0 to 55 0 C / Humidity 5 to 95% non condensing Mounting Operating Conditions Note For process conditions other than above please consult factory. 21

30 P FL-100 TWO WIRE TURBINE FLOW METER FL-100 DIMENSIONAL DETAILS D 100 mm 30 mm FD Line Size Flow Range Flange Details ANSI 150(B 16.5) m³/hr LPM D C R DBC d FD 15NB 0.4 to to NB 0.8 to to NB 1.6 to to NB 3.4 to to NB 6.8 to to NB 13.5 to to NB 27.0 to to Magnetic pick-up assembly SS 316 Flange RF DBC R D (OD)Outer Diameter of Flange No. of Holes For ½ to 3 & 4 to 6 C Thickness of flange R Diameter of Raised face DBC Diameter of bolt circle d Size of Hole FD Flange Diameter D mm d Note Typical mounting dimensions for reference ORDERING INFORMATION psi 4 0 Other 0 Other 0 Triclov er 3 15 mm to Pulse (Open 0 Remote 0 V Jewel PH 0 0 Flange 0 Collector) 150 mm d 2 0 Integral 0 Tungsten 4-20 ma 0 Thread 0 Carbide Sleeve ed 1 SERIES Line Size Electronics Bearing Rotor Output Process Pressu Connect re ion Ratting 600 psi Mtr 300 psi Mtr 150 psi 01 5 Mtr Remote Cable Length FL mm A 02 B 01 C 01 D 01 F 01 G 03 H 03 *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions. 22

31 Flow Indicator / Totalizers

32 FLOW INDICATOR TOTALISER FL-244 SPECIFICATIONS Averaging of inputs for turbulent flow Software calibration Input Linear / Square Rooted 4-20 ma, 1-5V / 0-5V, 0-10 KHz Display 4 digit, 0.5 Red LED for Flow Rate & 8 digit, 0.3 Red LED for Totaliser Accuracy Better than ± 0.25% of F. S. Power Supply V AC, 50 Hz; OPTIONAL 24V DC Mounting Flush of the Panel DIN std. OR wall mounting WP enclosure Transmitter Supply 24V DC, 30 ma Retransmission Output 4-20 ma / 0-5 V, Isolated Alarm Output Potential free Relay Contact - 2 nos. for High, Low / Batch Communication Port RS 485 / RS 232 supporting MODBUS RTU protocol FLOW INDICATOR TOTALISER Micro-controller Based with LCD FL-600 / FL-600 PTC / FL-600 OC SPECIFICATIONS Averaging of inputs for turbulent flow Optional Available with 3 inputs for Pressure, Temperature, Compensated Flow Optional Available for OPEN CHANNEL Flow measurement Input Linear / Square Rooted / 10 Point Linearisation Table 4-20 ma, 1-5 V / 0-5 V, 0-10 Khz Accuracy Better than ± 0.25% of F. S. Power Supply V AC, 50 Hz; OPTIONAL 24V DC Mounting Flush of the Panel DIN std. OR wall mounting WP enclosure Transmitter Supply 24 V DC, 30 ma Retransmission Output 4-20 ma / 0-5 V, Isolated Alarm Output Potential free Relay Contact for High, Low / Batch Communication Port RS 485 / RS 232 supporting MODBUS RTU protocol 23

33 BARGRAPH INDICATORS DPI-160-1/ DPI SPECIFICATIONS Multi color bargraph display with 4 digit LED display for process variable Cold junction compensation for Thermocouple input. No. of Bargraph Segments 101 Nos. No. of Channels 01 No. (OPTIONAL DUAL CHANNEL) Input LINEAR 4-20mA, 0-20mA, 0-6V, 1-5V, -20µA to +20µA / RTD /THERMOCOUPLE Accuracy Better than ± 0.5% of F. S. for TC & ± 0.1% F.S. for other inputs Power Supply 24V DC ± 10% OPTIONAL Transmitter Supply 24 V DC, 30 ma / 60 ma Output 4-20 ma / 0-5 V, Isolated per channel, Alarm Output Potential free Relay Contact - 4 nos. Communication Port RS 485 UNIVERSAL INPUT PROCESS INDICATOR DPC-808 SPECIFICATIONS Cold junction compensation for Thermocouple input. Open sensor indication, Software calibration. Input 1 No; Universal - RTD / Thermocouple / Current /Voltage Display 4 x 1 digit, 0.8, 7 seg. Red LED Accuracy Better than ± 0.5% of F. S for TC & ± 0.25% F. S. for other inputs Power Supply 1) 24 V DC ; 2) V AC, 50 Hz Enclosure 1) Din std. ; 2) Weather-proof, IP-65; 3) Flameproof OPTIONAL Transmitter Supply 24 V DC, 30 ma Retransmission Output 4-20 ma / 0-5 V, isolated Alarm Output Potential free Relay Contact - 2 nos. Communication Port RS 485 / RS 232 with MODBUS RTU Protocol 24

34 DIGITAL PROCESS INDICATOR DPC-100/200/300 PROCESS SCANNER SC-204 SPECIFICATIONS Cold junction compensation for Thermocouple input. Open sensor indication, Software calibration. No. of Input 01 No. (OPTIONAL UPTO 3 INPUTS) Input Universal - RTD / Thermocouple / Current /Voltage Display 4 x 1 digit, 0.8, 7 seg. Red LED (OPTIONAL UPTO 3 DISPLAYS) Accuracy Better than ± 0.5% of F. S for Thermocouple & ± 0.25% F. S. for other inputs Power Supply 1) 24 V DC ; 2) V AC, 50 Hz OPTIONAL Transmitter Supply 24 V DC, 30 ma Retransmission Output 4-20 ma / 0-5 V, isolated Alarm Output Potential free Relay Contact - 2 nos Communication Port RS 485 / RS 232 with MODBUS RTU Protocol SPECIFICATIONS Individual alarm output for each channel. Long lasting battery backup for memory. Cold junction compensation for TC input. No. of Channels 8/16 nos. Input DEDICATED RTD/ TC/mA/ Voltage OR UNIVERSAL Display Scan Time Programmable from 1 to 99 seconds Power Supply V AC, 50 Hz / 24 V DC Accuracy Better than ± 0.25% F. S. for TC & RTD, ± 0.1% F. S. for other inputs Response Time < 100 msec per channel Output (common for all channels) RS 232/RS485 ; Printer Port (80 column parallel) ; Relay output OPTIONAL Alarm Output (Individual per channel) Potential free Relay Contacts for High & Low 25

35 DUAL INPUT ANALYSER UAC 100 Single / Dual channel. SPECIFICATIONS Input from ph/orp/conductivity/do2 Electrode and 4-20mA. Auto temperature compensation & Inbuilt memory for data logging. Power Supply 1) 24 V DC ; 2) 85 to 265V AC, 50Hz Type of Inputs From any ph / ORP / Conductivity / DO2 Electrode Input Range 1) ph, 0 to 14 ph 2) ORP, to 2000 mv 3)Conductivity, 0.01µS/cm to 10mS/cm 4)DO2, 0 to 20 ppm 5)Temperature, 0 to 150 deg C Output 1) 4-20 ma DC, HART (HART Optional for one channel) 2)Potential free Relay Contact (1 c/o, 1 Amp) - 2 nos, programmable 3)Serial communication RS485/RS232 ANALYTICAL TRANSMITTERS CT-100S / PH-100S / DO-100S SPECIFICATIONS On-line measurement. Auto/Manual temperature compensation Power Supply 24 V DC Display Local display 128X64 COG with backlit Type of Input From Conductivity / PH / DO Electrode (Single I/P) Type of Output 4-20 ma DC with HART COMMUNICATION, 2 wire Isolated Accuracy ± 0.25% F. S. Response Time < 1000 msec Process Connection Through BNC connector / Through Terminals Dimensions 135 (H) x 249 (W) including cable gland x 170 (D) in mm approx. Mounting 2 Pipe Mounting Housing Cast aluminium with epoxy coating NEMA 4X (IP- 65) 26

36 ANALYTICAL INDICATOR CONTROLLERS CT-801 / PH 104 / DO 801 SPECIFICATIONS Single channel ON/OFF Indicator controller. Open sensor indication. Software calibration. Power Supply 1) 24 V DC ; 2) V AC, 50 Hz Type of Input From Conductivity / PH / DO Electrode (Single I/P) Display 4 digit, 0.5 LED for ph & 16X2 LCD for Conductivity & DO Accuracy Better than ± 0.25% F. S. Process Connection Through BNC connector / Through Terminals Enclosure 1) DIN Std. 2) Weather-proof, IP-65 Mounting Flush of the Panel DIN std. & wall mount for FLP/WP enclosure Output 1) 4-20 ma DC 2)Potential free Relay Contact (1 c/o, 1 Amp) - 2 nos, programmable 3)Serial communication RS485/RS232 ANALYTICAL SENSORS CONDUCTIVITY SENSOR / ph - SENSOR / DO2 - SENSOR SPECIFICATIONS Large selection of electrodes to suit a wide variety of applications. Easy to install with stable performance & reliable measurement Range 1) For ph, 0 to 14 ph 2) For ORP, to 2000 mv 3) For Conductivity, 0.01µS/cm to 10mS/cm 4) For DO2, 0 to 20 ppm 5) For Temperature, 0 to 150 deg C System Accuracy ± 2 % OF F.S. Operating Temperature Range Customer to specify Operating Pressure Customer to specify Temperature Compensation Through RTD upto 100 o C Cable Length Upto 3 Mtrs 27

37 Mechanical Meters

38 28 ROTARY VANE WHEEL DRY-DIAL WATER METER DESCRIPTION Magnet drive, magnet-proof and resistance exterior magnet interference. Keep the reading easy and clear in a long-term service. FEATURES * Magnet drive, magnet-proof and resistance exterior magnet interference. * Keep the reading easy and clear in a long-term service. * The cover can be turned discretional. * Selected high quality materials for steady & reliable characteristic and good looking. * Brass or stainless steel body, hot water meter, magnet-proof device and remote reading transmission system for option. Note technical data conforms to ISO4064. TECHNICAL SPECIFICATIONS Main Technical Data Size (mm) Q3/Q1 Max Flow (m³/h) Nominal Flow (m³/h) Transitional Flow (m³/h) Min Flow (m³/h) Dimensions and weight Type LXSG- 40E size (mm) Length (mm) Width (mm) Height (mm) Connecting Thread G2B 4.8 Weight (kg)

39 29 ROTARY VANE WHEEL MULTI JET DRY METAL LXSG WATER METER DESCRIPTION Rotary vane wheel multi jet water meter Dry type and magnet drive water meter Easy reading High accuracy Remote water meter for option. 201 or 304 stainless steel water meter Size 15mm-25mm ISO 4064 class B Horizontal type and vertical type are available Pulse output for option FEATURES 1. High quality stainless steel material, NO.201 or NO Multi jet, dry dial or wet dial are available 3.Regular type and pulse-output communication for option. 4.Nice looking and perfect performance. 5.Magnet drive water meter, magnet-proof and resistance exterior magnet interference. 6.Water meter can keep the reading easy and clear in a long-term service. 7.The cover of water meter can be turned discretional. 8.Selected high quality materials for steady & reliable characteristic and good looking. 9.Brass or stainless steel body, hot water meter, magnet-proof device and remote reading transmission system for option Note technical data confirm to ISO4064 TECHNICAL SPECIFICATIONS Water meter size and basic information are below TYPE SIZE LENGTH WIDTH HEIGHT CONNECTING THREAD mm LXSG-15E / G3/4B LXSG-20E / G1B LXSG-25E G1 1/4B LXSG-32E G1 1/2B LXSG-40E G2B LXSG-50E G2 1/2B GB D=Φ165 D=Φ125

40 Valves and other accessories

41 30 BRASS GATE VALVES JY -101 Brass gate valve Forged brass body size 1/2 ; 3/4 ; 1 ; 1-1/4 ; 1-1/2 ; 2" ;2-1/2 ; 3 and 4" JY -102 Brass gate valve Forged brass body size 1/2 ; 3/4 ; 1 ; 1-1/4 ; 1-1/2 ; 2" ;2-1/2 ; 3 and 4" JY -103 Brass gate valve (CXC) Forged brass body size 1/2 ; 3/4 ; 1 ; 1-1/4 ; 1-1/2 ; 2" ;2-1/2 ; 3 and 4"

42 31 BRASS GATE VALVES JY -104 Brass gate valve Forged brass body size 1/2 ; 3/4 ; 1 ; 1-1/4 ; 1-1/2 ; 2 JY -105 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -106 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

43 32 BRASS GATE VALVES JY -107 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -108 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -109 Brass compression gate valve Forged brass body size 15mm; 18mm; 22mm; 28mm; 35mm; 42mm; 54mm JY -125 Brass gate valve with flange Cast brass body size 11/2" 2" 21/2" 3" 4"

44 33 BRASS STOP VALVES JY -110 Brass stop valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2 JY -111 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -112 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

45 34 BRASS STOP VALVES JY -113 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -114 Brass stop valve Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -115 Brass stop valve Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

46 35 BRASS STOP VALVES JY -116 Brass compression stop valve forged brass body size 15mm 22mm JY -117 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -124 Brass stop valve Cast or forged brass body size " 2

47 36 BRASS CHECK VALVES JY -118 Brass check valve Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"4" JY -119 Brass check valve (CXC) Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -120 Brass spring check valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"

48 37 BRASS FOOT VALVES JY -121 Brass foot valve With stainless steel filter forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" J Y -122 Brass foot valve With brass filter Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY -123 Brass Y pattern strainer With stainless steel filter Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

49 38 BRASS BALL VALVES JY-201 Brass ball valve (standard port) F/F Forged or cast brass body Steel handle size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" JY-202 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" JY-203 Brass ball valve (Full port) M/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY-204 Brass ball valve (Full port) M/M Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

50 39 BRASS BALL VALVES JY-205 Brass ball valve with drain (Full port) Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY-206 Brass ball valve (standard port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" JY-207 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" JY-208 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

F6700 ELECTROMAGNETIC METER

F6700 ELECTROMAGNETIC METER EETROMAGNETI FOW TRANSMITTER Special Features: F6700 Full Bore type Simple and ost effective onstruction Absolutely Maintenance free Suitable for all conductive liquids and slurries Outstanding Accuracy

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids Magnetic Inductive Flowmeter for Conductive Liquids measuring monitoring analyzing EPS / UMF2 High Accuracy: 0.3 % of Actual Flow Maintenance-free No Pressure Drop Wide Variety of Lining and Electrode

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES: KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage

More information

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell Transmitters Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell Oldest design, developed during WW 2. Can be used for flow, level, and pressure, vent low side. Several ranges 0 to

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Industrial OG meter series IOG Inline and flanged oval gear meter

Industrial OG meter series IOG Inline and flanged oval gear meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

F-2500 SERIES VORTEX METER

F-2500 SERIES VORTEX METER F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing

More information

Turbidity and Suspended Solids Transmitter

Turbidity and Suspended Solids Transmitter Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

INSTRUMENTS & TECHNOLOGY

INSTRUMENTS & TECHNOLOGY Manufacturer and Exporter of Plot No. C1B-888/1/A, G.I.D.C. Estate, Makarpura Vadodara - 390010. Gujarat (INDIA) +91 9722212144 / 9979119649 +91 265 2637999 kabirinstru108@gmail.com info@kabirinstruments.com

More information

tprime TM Series 280T

tprime TM Series 280T MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.

More information

RUN ACCUM. TOTAL STOP BAT LOW HIGH

RUN ACCUM. TOTAL STOP BAT LOW HIGH TURBOPULSE TURBINE FLOWMETER INSTRUCTION MANUAL gal RUN ACCUM. TOTAL STOP BAT LOW HIGH RESET > PROGRAM ENTER ACCUM TOTAL ^ RATE TOTAL TP050 TABLE OF CONTENTS 1. INTRODUCTION Overview 1 1.1 Model number

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Model TUR-200D Turbine Flowmeter

Model TUR-200D Turbine Flowmeter General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

ProcessAutomatic EZ-Mag

ProcessAutomatic EZ-Mag ProcessAutomatic EZ-Mag THE EZ-CHOICE Robust Design: The highly robust and compact EZ-Mag is designed to be able to cope with tough environments. Whether installed in-house or on a vehicle, you can be

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits. GE Measurement & Control Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically for custody

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

MAIN FUNCTION FEATURES. . D = v t /2

MAIN FUNCTION FEATURES. . D = v t /2 ttp e-te com e-ma l o e-te com LT ASONIC LE EL MEAS EMENT Tel -2-22 Fa -2-22 2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems.

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems. Cerama~Flow CF900 Wear Resistant Magnetic Slurry Flowmeter Superior Measurement Systems www.hmagroup.com.au Technical Specification NautiFlow NF-1 Battery Powered Electromagnetic flowmeter Intelligent

More information

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electro-Magnetic Flowmeters Sensors MagMaster MFE Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year

More information

Flow meter Type Recordall (RCDL)

Flow meter Type Recordall (RCDL) Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Flow meter Type Recordall (RCDL) Bronze model Features

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters EMF Series ELECTROMAGNETIC FLOWMETER Description Introduction for EMF Series of Electromagnetic Flowmeters The Electromagnetic Flowmeters(EMF) can be used to accurately measure the flowrate of liquids,

More information

ULTRASONIC HEAT METER

ULTRASONIC HEAT METER MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.

More information

Insertion Flow Meters. Municipal Market Customer Presentation

Insertion Flow Meters. Municipal Market Customer Presentation Insertion Flow Meters Municipal Market Customer Presentation Topics for Discussion Product Description Product Offering Product Name Principal of Operation Why the New FPI Mag? Development Team Comparison

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

Field IT Electro-Magnetic Flowmeters Sensors

Field IT Electro-Magnetic Flowmeters Sensors Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up

More information

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type magnetic flow meters Safmag Flanged Type Lining Electrodes Accuracy 25mm to 800mm Natural rubber Neoprene Ebonite Polyurethane PTFE Hastelloy C Monel Titanium Tantalum Conductive rubber 110 / 220 V AC

More information

flow measurement solutions RIM10 series rotor insertion flowmeters

flow measurement solutions RIM10 series rotor insertion flowmeters flow measurement solutions RIM10 series rotor insertion flowmeters R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits. GE Sensing & Inspection Technologies Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 Data sheet MULTICAL 6L2 Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 M15 0200 Contents Calculator functions 3 Cabinet design 7 Approved meter data 8 Electrical

More information

DY-LWGY Liquid turbine flow meter

DY-LWGY Liquid turbine flow meter Typical Application: liquid with no impurities and no corrosion, such as water, diesel, methanol. DY-LWGY Liquid turbine flow meter One. Overview DY-LWGY series Turbine Flow has its simple structure, light

More information

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by

More information

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Botlek Studiegroep Basics Electro Magnetic Flowmeters Arjan Meerveld, ABB b.v. / 2 juni 2016 Botlek Studiegroep Basics Electro Magnetic Flowmeters ABB Group 8 June 2016 Slide 1 Measuring Principle of EMF Faraday s law (year 1831) Measurement electrodes Magnetic

More information

Electromagnetic amplifier type ModMAG M10 for all detectors

Electromagnetic amplifier type ModMAG M10 for all detectors Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors

More information

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity Ideal for monitoring opacity and smoke levels in the exhaust gas of industrial combustion or air filtration processes. In situ measurement directly in exhaust gas flow using the widely accepted light transmission

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability zirconium oxide measuring tube Extreme long-term stability Most compact and lightweight design

More information

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs s Meriam s Flow Sensors are lab-tested and field-proven flow elements perfect for gas, liquid or steam service. With thousands in use worldwide, the continues to be the right choice when ease of installation,

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information