DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island incl. SMA ENERGY METER

Size: px
Start display at page:

Download "DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island incl. SMA ENERGY METER"

Transcription

1 3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER enwitecordernumber Customerarticlenumber Type designation Match code Application Batteryinverter ENERGY METER Grid structure BatteryBackupDistribution 1PH incl. SMA ENERGY METER 3PH_IPC_SMA.SI_BBDAP_20KW_1PH_INT.EM_DACH_1.0 Standby power SMA "Flexible Storage System" Sunny Island 4.4M12 from firmwareversion 1.00.xx.R Sunny Island 6.0H12 from firmwareversion 1.00.xx.R Sunny Island 8.0H12 from firmwareversion 1.00.xx.R EMETER20 from firmwareversion R TT or TNS system Sunny Island feed in: 1 phase! (=1 x Sunny Island) Page 1 von 5

2 3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER SCOPE OF DELIVERY A B C D E F G H I J K L M N O P Q R Position Quantity Designation A 1 Battery Backup Distribution 1PH B 2 Cable gland M40 x 1,5 (clamping range Ø 16 28mm) C 2 Enlargement adaptor from M32 to M40 D 3 Cable gland M32 x 1,5 (clamping range Ø 13 21mm) E 2 Cable gland M25 x 1,5 (clamping range Ø 9 17mm) F 1 Reduction adaptor from M20 to M12 (for pressure equalization valve) G 5 Cable gland M20 x 1,5 (clamping range Ø 6 13mm) H 3 Locknut M32 I 2 Locknut M25 J 6 Locknut M20 K 1 Special sealing insert for CAT 5e cable (M25) L 1 Pressure equalization element M 1 Cover caps for fastening screws N 1 Installation manual O 1 Original accessories kit SMA Energy Meter P 3 Ferrulefuse 10x38mm (1A fast; Littelfuse #KLKD or Bussmann #KTK) 2 pieces in the fuse holders; 1 piece in the accessories kit (spare part) Q 1 Warning label high voltage R 1 Label image with reference to an island mode system ability Page 2 von 5

3 3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER ORIGINAL CIRCUIT DIAGRAM SMA Grid disconnection Phase coupling for singlephase operation * 1 The indicated values are recommended by SMA Solar Technology AG. The electrical devices must be designed in accordance with the locally applicable standards and directives * 2 Only applicable for TT grid configuration * 3 Not required for systems without increased selfconsumption * 4 Requirements for thermal fuse: fuse 1A, nominal cold resistance of at least 0,2Ω and melting integral max. 1A²s Grounding device : Phase coupling inclusive; with SMA Energy Meter Page 3 von 5

4 3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER ORIGINAL CIRCUITRY OVERVIEW SMA PV ARRAY PV INVERTERS AUTOMATIC TRANSFER SWITCH GROUNDING DEVICE PHASE COUPLING Existing house distribution board with protective devices** AC LOADS At connection AC2, always connect the neutral conductor to NTT BATTERY FUSE * In the event of grid failure, maximum tripcapable circuit breakers: Trip characteristic B6 (SI3.0M11/SI4.4M11) or B16/C6 /SI6.0H 11/SI8.0H11) GRID DISCONNECTION BATTERY Lithiumion battery Leadacid battery UTILITY GRID Gridconnection point with energy meter of the electric utility company TN or TT system WLAN DC+ cable DC cable Line conductor Neutral conductor Grounding conductor Data cable WAN Network cable Speedwire (LAN) Terminator : with SMA EnergyMeter! Page 4 von 5

5 3PHBatteryBackupDistribution for 1x Sunny Island incl. SMA ENERGY METER TECHNICAL DATA Rated operating voltage AC [V] 3PH 230/400 Rated insulation voltage [V] 400 Operating frequency [Hz] 50/60+/5% Max. prospective short circuit current [ka] 10 Permitted grid structure TT / TNS Max. value of prefuses [A] 63 A Max. thermal power [kw] 20 Standbyloss [W] ca. 15 Circuit breakers and fuses F1 Ferrule fuse 10x38mm F2 RCD (residual current protective device) F3 MCB (circuit breaker "C"characteristic) F4 MCB (circuit breaker "C"characteristic) F5 Ferrule fuse 10x38mm F6 MCB (circuit breaker "C"characteristic) F7 RCD (residual current protective device) Contactors IEC/EN 61095; IEC/EN609471; IEC A fast Type A /40A0,03A 1A fast Type A/40A0,03A Q2 grid disconnection AC1 [A] 63 Q3 grounding device I AC1 [A] 40 Q4 grounding device II" AC1 [A] 40 Q6 "phase coupling" AC1 [A] 63 Control voltage Humfree Connections/terminals (springloaded terminals) Terminal block X1/X2/X3 X4 X5 (L1/N/PE) X5 (1/2/3/4) Cable glands Wire type Cross section [mm²] max Stripping length [mm] V AC/DC Terminal block Size (metrical) Clamping range [mm] X1 M32/M /1628 X1 PE M X2 M32/M /1628 X3 M X4 M X5 L1/N/PE M X5 1/2/3/4 M Ferrule General data Dimensions (WxHxD) [mm] 448x622x161 Weight [kg] 11,5 Operating temperature range [ C] Temperature transport/storage [ C] Temporary max. 24 hours [ C] 70 Humiditycondensing allowed / Humidity permitted range [%] 5 95 max. altitude above sea level [m] 2000 Protection class IP (EN 60529) 65 Outdoorapplication permitted / Installation type Protection against electric shock (EN 61140) Case material Indoor area II Polycarbonate RoHSconformity (2011/65/EU) Colour of case Way of mounting cover Locking system Relevant standards Switching devices distribution boards operated by ordinary people (DBO) Miscellaneous Consider installation manual! similar RAL7046 wall mounting transparent without tool EN EN EN Customer tariff number Page 5 von 5

DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island

DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island 3PHBatteryBackupDistribution for 1x Sunny Island enwitecordernumber 10012549 Customerarticlenumber Type designation Match code Application Batteryinverter Grid structure BatteryBackupDistribution 1PH prepared

More information

INSTALLATION MANUAL. Automatic Transfer Switch Battery Backup Distribution. FLEXIBLE STORAGE within Battery Backup Function

INSTALLATION MANUAL. Automatic Transfer Switch Battery Backup Distribution. FLEXIBLE STORAGE within Battery Backup Function INSTALLATION MANUAL Automatic Transfer Switch Battery Backup Distribution FLEXIBLE STORAGE within Battery Backup Function BATTERY BACKUP DISTRIBUTION Sunny Island SI 3.0M-11/SI 4.4M-11 from Firmware 3.2

More information

Automatic Transfer Switch Battery Backup Distribution

Automatic Transfer Switch Battery Backup Distribution INSTALLATION MANUAL Automatic Transfer Switch Battery Backup Distribution FLEXIBLE STORAGE within Battery Backup Function United Kingdom of Great Britain and Northern Ireland Sunny Island SI 3.0M-11/SI

More information

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H ENGLISH SI44M-80H-12-OffGrid-IA-en-11 Version 1.1 Legal Provisions SMA Solar Technology AG Legal Provisions The information contained

More information

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function Battery-Backup Systems including Increased Self-Consumption with SUY ISLAD 4.4M / 6.0H / 8.0H and SUY HOME MAAGER EGLISH SI44M-80H-2-BBF-IA-en-0

More information

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION Circuitry Overviews, Schematic Diagrams and Material Lists SI-Ersatzstrom-PL-en-23 Version 2.3 ENGLISH Legal Provisions SMA

More information

500 / 630 / 720 / 760 / 800 / 850 / 900

500 / 630 / 720 / 760 / 800 / 850 / 900 SUNNY CENTRAL STORAGE 500 / 630 / 720 / 760 / 800 / 850 / 900 SCS 500 / SCS 630 / SCS 720 / SCS 760 / SCS 800 / SCS 850 / SCS 900 Durable Full nominal power in continuous operation at ambient temperatures

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

Technical specifications

Technical specifications xstorage Home Technical specifications System overview The following Table 1 provides a general overview of battery capacity and inverter power range combinations that can be integrated together with the

More information

Operating Manual NA-BOX 12

Operating Manual NA-BOX 12 Operating Manual NA-BOX 12 NA-BOX-12-3-20-BE-en-11 Version 1.1 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar

More information

xcomfort EWK Compact Distribution Boxes

xcomfort EWK Compact Distribution Boxes Product catalogue EWK Compact Distribution Boxes Release 2017-03 Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers New Central Gridtied PV Inverters 500kW/MW level Ttype modular inverters MW/ PV power containers MW/ PV Power Containers Product Introduction Superior integration and turnkey design Integrated PV inverters,

More information

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE.

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE. GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE. WWW.REINHAUSEN.COM SAMSUNG ESS INSIDE 1 GRIDCON ACF ESS 2 ENERGY STORAGE SYSTEMS IMPROVE FLEXIBILITY. Energy storage systems are an attractive

More information

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range Professional Photovoltaic Distributors NEW with extended product range 10 11 Safe product solutions conforming to standards for photovoltaic plants Industrial Electrical Power Distribution Systems Solar

More information

SMA FLEXIBLE STORAGE SYSTEMS. SMA Solar Technology AG

SMA FLEXIBLE STORAGE SYSTEMS. SMA Solar Technology AG SMA FLEXIBLE STORAGE SYSTEMS SMA Solar Technology AG SMA FLEXIBLE STORAGE SYSTEM Solar inverter Home Manager Energy Meter Sunny Island Controllable Appliance via Plugwise automation units 2 Sunny Island

More information

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and end users who require

More information

IP65 Wall mounted distribution boards ECH

IP65 Wall mounted distribution boards ECH IP65 Wall mounted distribution boards ECH Available in 4, 8, 2, 24, 36 modules Applications: Watertight wall-mounted distribution boards apply in domestic and industry architecture for mounting modular

More information

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Planning Guidelines SMA SMART HOME

Planning Guidelines SMA SMART HOME Planning Guidelines SMA SMART HOME The System Solution for Greater Independence ENGLISH SI-HoMan-PL-en-51 Version 5.1 Table of Contents SMA Solar Technology AG Table of Contents 1 Information on this Document...

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

Increased requirements on external DC-breakers for transformerless PV inverters in Australia

Increased requirements on external DC-breakers for transformerless PV inverters in Australia Increased requirements on external DC-breakers for transformerless PV inverters in Australia Are the requirements also expedient for PV plants with transformerless SMA PV inverters? Content The standard

More information

Quick Installation Manual Alpha ESS Battery with SMA Flexible Storage System V1.0

Quick Installation Manual Alpha ESS Battery with SMA Flexible Storage System V1.0 Quick Installation Manual Alpha ESS Battery with SMA Flexible Storage System V1.0 Germany Alpha ESS Europe GmbH Tel.: +49 (0)6103 459 160-1 E-mail: europe@alpha-ess.de Web: www.alpha-ess.de Add: Paul-Ehrlich-Straße

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20 Maintenance Manual SC500-800HE20-WH-en-10 98-4110410 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function Sunny Island 6.0H / 8.0H and Multicluster-Box 12 / NA-Box 12 / Grid-Connect-Box 12

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Solar inverter AX-series

Solar inverter AX-series Power Supplies Inverters Solar inverter AX-series 1-5kVA Multifunctional inverter NEU / NEW PV inverter PV / Battery Charger with 3-stage charge Battery-backed power supply Sine wave inverter with charging

More information

System description SMA FLEXIBLE STORAGE SYSTEM

System description SMA FLEXIBLE STORAGE SYSTEM System description SMA FLEXIBLE STORAGE SYSTEM Increased self-consumption with SUNNY ISLAND 4.4M / 6.0H / 8.0H and SUNNY HOME MANAGER ENGLISH SI44M-80H-12-FSS-IA-en-10 Version 1.0 Legal Provisions SMA

More information

SMA FLEXIBLE STORAGE SYSTEM

SMA FLEXIBLE STORAGE SYSTEM SMA FLEXIBLE STORAGE SYSTEM Now even more attractive with the German incentive program for storage systems Flexible Future-proof Intelligent Efficient Capability to upgrade almost any existing PV system

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Get ready for rising energy challenges. This is where xstorage Home can help

Get ready for rising energy challenges. This is where xstorage Home can help xstorage Home Get ready for rising energy challenges More and more people, factories, businesses connect to the grid around the world. How can you be sure there will still be power for you and your family

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

EAD10H80D EAD14H80D EAD17H80D

EAD10H80D EAD14H80D EAD17H80D 12.4 Technical data Consumer units and enclosures dimensions and data RCCB controlled surface mounting consumer units Eaton list Dimensions (mm) number w h d EAD2/3M63 154 223 101 EAD2/3M80 EAD4M63 235

More information

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK Energy storage kits for residential and commercial customers Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK SMA Smart Home Basic, Integrated and Flexible Storage

More information

Distribution boxes with suspension hook

Distribution boxes with suspension hook Distribution boxes with suspension hook Distribution boxes with suspension hook Pegasus Page 258 Dimensions: HxWxD = 220x140x140mm Imst Page 260 Dimensions: HxWxD = 197x197x120mm Freistadt Page 262 Kombi

More information

1.2 Switched socket outlets with interlock

1.2 Switched socket outlets with interlock . Switched socket outlets with interlock. OMNIA Series OMNIAPLUS Series ADVANCE Series ADVANCE System ADVANCE-GRP System ADVANCE-GRP Series 8 87 Switched socket outlets with interlock. IP IP/IP7 > V

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EST 2074 For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed:

More information

Internationally approved.

Internationally approved. E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards ALPHA 400 - DIN Wall-Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards (Flat Pack) /6 8GK1 surface-mounting distribution boards Pre-Assembled Unequipped Distribution Boards /7

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Hilton Hunkin Senior Application Engineer SMA Solar Technology South Africa

Hilton Hunkin Senior Application Engineer SMA Solar Technology South Africa Hilton Hunkin Senior Application Engineer SMA Solar Technology South Africa Sunny Island Load Shedding Flexible energy self-storage: Covering zero export to grid SUNNY ISLAND ON GRID, OFF GRID APPLICATION:

More information

Installation Guide SUNNY TRIPOWER 60

Installation Guide SUNNY TRIPOWER 60 Installation Guide SUNNY TRIPOWER 60 STP60-JP-10-IA-en-10 Version 1.0 Legal Provisions The information contained in these documents is the property of SMA Solar Technology AG. Any publication, whether

More information

Motor Starter Reverse MSR22-FBP

Motor Starter Reverse MSR22-FBP Technical Description FBP FieldBusPlug V6 Motor Starter Reverse MSR22-FBP V 6 MSR22-FBPMotor Starter Reverse MSR22-FBP: Motor branch connection 1 motor, 2 directions of rotation Connecting plug for external

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Catch Eco Range : Technical Specification Sheet

Catch Eco Range : Technical Specification Sheet Catch Eco Range : Technical Specification Sheet Battery Hybrid Inverter AC Coupled Inverter Lithium phosphate technology High cycle life with warrantied throughput Indoor and outdoor options (IP21 and

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

Step 1: Collection of required data

Step 1: Collection of required data Step 1: Collection of required data If the relevant parameters of the interfaces are known, it is possible to dimension ASSEMBLIES 3 Installation and environmental conditions 4 Operating and servicing

More information

Power Conversion System The Best Technology for your photovoltaic and storage system

Power Conversion System The Best Technology for your photovoltaic and storage system The Best Technology for your photovoltaic and storage system The Best Technology for your photovoltaic and storage system EEI. Experience and Reliability since 1978 EEI s mission started in 1978 coming

More information

AME. Rectifier - Battery charger. Industrial applications: Key features:

AME. Rectifier - Battery charger. Industrial applications: Key features: Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);

More information

SUNNY TRIPOWER CORE1 - STP 50-40

SUNNY TRIPOWER CORE1 - STP 50-40 Skype bornay@bornay.com (+34) 965 560 025 SUNNY TRIPOWER CORE1 - STP 50-40 Sunny Tripower Core 1, the World's first free standing inverter, with up to 60% faster installation for commercial PV systems.

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT Maintenance Manual SCCP-WH-B4-en-20 98-4046720 Version 2.0 EN SMA Solar Technology

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

1.1 GENERAL CHARACTERISTICS

1.1 GENERAL CHARACTERISTICS 1.1 GENERAL CHARACTERISTICS General characteristics - Frame Values Unit Model: Conceptpower DPA 500, UL Series Power, rated: Apparent 500 kva Active 500 kw Power, range 100-3000 kw UPS type: online, transformerless,

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

KEWTECH. KT56 digital multi function tester. Instruction manual

KEWTECH. KT56 digital multi function tester. Instruction manual KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating

More information

1.1 Scope Characteristics General system description 1-2

1.1 Scope Characteristics General system description 1-2 TABLE OF CONTENTS 1. INTRODUCTION 1.1 Scope 1-2 1.2 Characteristics 1-2 1.3 General system description 1-2 2. BOXES 2.1 Box overview 2-2 2.2 Box accessories 2-2 2.3 Box fittings 2-9 2.3.1 Flanges for increasing

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A Rectifier - Battery charger AMS VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines); Energy & Power Generation

More information

TANZANIA BUREAU OF STANDARDS

TANZANIA BUREAU OF STANDARDS EDC 5 (5235) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD (Draft for comments only) Part 2: Application of Inverters TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 T able of content 1 2 3 4 5

More information

Standard-compliant components for commercial photovoltaic applications

Standard-compliant components for commercial photovoltaic applications Standard-compliant components for commercial photovoltaic applications Safe and economical construction and operation of commercial photovoltaic systems In view of the limited resources of fossil fuels,

More information

2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display

2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display General Model name Product no. 2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display 904461011 2 x type 2 socket, 1-phase, max. 2x32A input, RCD type A, 6mA detection, Display

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important

More information

APS-PV-Series 1000 V DC

APS-PV-Series 1000 V DC APS-PV-Series 1000 V DC utdoor PV hybrid inverters, with output power ranging from 650 up to 3280 kva. The APS-Series 1000 V DC solution for large scale PV installations. outdoor PV central inverter is

More information

AMTRON Xtra (E/R), Trend E, Premium (E/R)

AMTRON Xtra (E/R), Trend E, Premium (E/R) The MENNEKES AMTRON Wallbox is a charging station for use in private and semi-public areas, such as private land, company car parks and depots. Charging acc. Mode 3 (IEC 61851) Vehicle connectors and charging

More information

MTPi2000C - 80 KW (RANGE)

MTPi2000C - 80 KW (RANGE) MTPi2000C - 80 KW (RANGE) TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MTPi2000C - 80 kw system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipments with back up batteries.

More information

GPRS UTP/LAN. Cable gland, range for cable thicknesses 14mm till 25,5mm

GPRS UTP/LAN. Cable gland, range for cable thicknesses 14mm till 25,5mm General Model name Part no. 1 x type 1 fixed cable 5 m, 1-phase, 16A, Plug & Charge 904460001A 1 x type 2 fixed cable 5 m, 1-phase, 16A, Plug & Charge 904460001B 1 x type 1 fixed cable 8 m, 1-phase, 16A,

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Commando Safetyswitch

Commando Safetyswitch 80 Commando Safetyswitch Commando Safetyswitches are manufactured from Polybutylene Terephthalate (PBT) for maximum impact resistance. The range offers a selection of IP54 and IP65 ratings to cover a variety

More information

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL³ 400 metal distribution cabinets, free-standing Cat. No(s) : 20103/04/05/06/07/08/18/19/23/ CONTENTS PAGE 1. General characteristics...

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011 Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV

More information

Solid-rubber distribution boxes - mobile

Solid-rubber distribution boxes - mobile Solid-rubber distribution boxes - with fuse 16 modules with fuse portable, handy solid-rubber distribution box dimensions: WxHxD = 320x320x320 mm lifting hinged cover with 2 quick acting closures fuses,

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

BC Mini Contactor VDC

BC Mini Contactor VDC ABB Mini Contactor 110-125VDC General Information Extended Product Type Product ID GJL1213001R0014 EAN 4013614052859 Catalog Description Long Description Mini Contactor 110-125VDC The BC6-30-01 mini contactor

More information