NY 55 Mall Drive, Commack, NY LA Earl St, Torrance CA 90503
|
|
- Jonah McDonald
- 5 years ago
- Views:
Transcription
1
2 NY 55 Mall Drive, Commack, NY LA Earl St, Torrance CA Tel NY (toll free) LA (toll free) Fax NY LA Web
3 IRL Series Infrared Illuminators INSTALLATION INSTRUCTIONS
4 IMPORTANT For best results, please read this Instruction Booklet prior to installing the IRL Series illuminator. CSA Certified / UL Listed CLASS 2 power adaptors must be used in order to comply with electrical safety standards. EU Directives covered b y this declaration: 72/9/EC Low Voltage Directives 89/336/EEC Electromagnetic Compatibility Directive This installation should be made by a qualified service person and conform to all local codes. CBC (America) Corp. will not be responsible for injuries or damages resulting from the improper installation or use of any illuminator sold by CBC (America) Corp., their agents, distributors or dealers.
5 5. GENERAL SPECIFICATIONS LED Type...High Perf. 850nm / 940nm LED Beam Angles... 60deg. (W), 30deg. (M) Operational Range C to +60 C (-58 F to +140 F) Humidity Range...Up to 85% (relative) Power Supply... 12V dc or 24V ac (60Hz), 10W Housing.Extruded Aluminum Dimensions...168mm x 91mm x 89mm Weight lbs. Subject To Change Without Notice. 16
6 LEDs are not ON - Cover the photocell to activate power to the LEDs ( up to 30 seconds delay for activation ). - Adjust the photocell s variable resistor towards the ON position. - Adjust power to the LEDs. LEDs are not turning OFF when sufficient ambient light is present - Make sure the photocell is not covered or hidden behind any object. - Adjust the photocell s variable resistor towards the OFF position (up to 30 seconds delay). The LEDS will stay ON or OFF if the adjustments are at full turn. Note: 15
7 Page Description...1 Unpacking...2 Parts List...2 Items Required for Installation...2 Mechanical Specifications...3 Initial Preparations...5 Guidelines...6 Section 1. Voltage Setting...7 Section 2. Adjustments Illuminator...10 Section 3. Illuminator Mounting...12 Section 4. Troubleshooting - Illuminator...13 Section 5. General Specifications...16
8 DESCRIPTION The IRL Series Infrared Illuminator is a versatile short to mid-range illuminator (60 feet / 20 m with 850 nm LED s, at a 30 beam angle). It is encased in a weather-tight cast and extruded aluminum housing. There are 2 mounting options for these units. 1) a U-bracket for standalone mounting (Model IRL-UB) and 2) a flat bracket for mountgin together with CBC (America) Corp. HWB and HJB Housing series. The brackets must be ordered separately depending on application. As a 12 VDC / 24 VAC unit, it is ideal for existing CCTV installations and new CCTV projects that specify 24 hour surveillance in and around buildings in covert or semi-covert conditions. A voltage regulator circuit allows for 12V dc or 24V ac operation, and a range in between, also providing protection from voltage surge, transient spikes, and reverse voltage. Contact CBC (America) Corp. for information. NY: LA:
9 4. TROUBLESHOOTING GUIDE LEDs PROBLEM POSSIBLE SOLUTION Fuse Blows Don t know if LEDS are ON - Check the fuse rating. - Check for shorting between the housing and the input power wires. -850nm LEDs will have a faint red glow when ON. -940nm LEDs are covert. -Aim the LEDs directly at an IR sensitive camera, or use a mirror to see the lights through the EX35 camera, or wait for the LEDs to warm up (two minutes). 14
10 3. ILLUMINATOR MOUNTING The IRL Series can be mounted using the optional L bracket or the standard U bracket. 13
11 UNPACKING Care should be taken when unpacking. Check the parts list and confirm all items have been located. Inspect the equipment thoroughly to ensure nothing was damaged in transit. Contact CBC (America) Corp. if a problem is noted. PARTS LIST (items supplied with unit) - IRL Series illuminator assembly - Installation Instructions ITEMS REQUIRED FOR INSTALLATION (not supplied with unit) - U shaped Mounting Bracket Model IRL-UB (for standalone installations) - Flat Mounting bracket Model IRL-PB (for installation with HWB or HJB Housings - Phillips screwdriver - 3mm Allen key - Optional heavy duty L mounting bracket or die-cast aluminum mounting bracket - Hardware for illuminator mounting (bolts, etc.) 2
12 IRL Series MECHANICAL SPECIFICATIONS With U Mount Bracket IRL-UB ( See Section 6 - General Specifications, for additional information ) Side View 3
13 Step Step Step Carefully slide out the rear housing from the main enclosure. Make sure the gasket remains with the rear section.. Make the necessary adjustments as per Figures 1-1 to 1-2 on pages 8 to 9 respectively. Carefully slide rear section back into the main enclosure and re-install the cap screws. FIGURE 2 1 Rear Housing Removal 12
14 2. ADJUSTMENTS - ILLUMINATOR For optimum picture quality the illuminator brightness can be adjusted to match the camera. It would be beneficial for the installer to have a connected IR sensitive camera during this adjustment phase. The following steps show the installer how to access the Illuminator/LED board. Step Step Disconnect the power source to the illuminator. Remove the four cap screws with a 3mm Allen key. See Figure 2-1 on page
15 Optional Mounting with HWB and HJB Series Housings (Use optional Mounting Bracket IRL-PB) 4
16 IRL Series MECHANICAL SPECIFICATIONS ( See Section 6 - General Specifications, for additional information ) Front View 5
17 FIGURE 1 2 Terminal Block +12V dc Connection 10
18 See Section 2, Figures 2-1 if access to VRB is required. FIGURE 1 1 Terminal Block 24V ac Connections ( as shipped ) 9
19 INITIAL PREPARATIONS Determine the operating voltage at the installation site. The illuminator has been pre-wired at the factory for 24V ac operation. Section 1 Voltage Setting. All illuminators have been tested prior to shipment. After the wiring has been reconnected, it is advisable to check the illuminator s operation before installation. Select a suitable location that is protected from accidental damage, tampering, and environmental conditions exceeding the illuminator s specifications. Caution: The selected mounting location should not place the illuminator in a situation where its environmental specifications could be exceeded. Ensure the selected location is protected from falling objects, accidental contact with moving objects, and unintentional interference from personnel. Follow all applicable building codes. 6
20 The following installation guidelines must be followed: Locate the illuminator such that it cannot be easily interfered with, either intentionally or accidentally. Select a mounting surface capable of supporting the combined weight of the illuminator and mounting hardware under all expected conditions of vibration and temperature. Secure all cabling. Installations on drywall must use a ¼ bolt and drywall butterfly type anchor or superior connection. GUIDELINES Two basic requirements must be met before the IRL Series unit can be installed. 1. Voltage Setting 2. Illuminator Wiring & Settings Sections 1 and 2 will guide the installer through these settings and adjustments. 7
21 1. VOLTAGE SETTING The IRL Series, when shipped, is connected for 24V ac operation. Note: Input voltages between 13.5 and 28V, ac or dc, will work in the 24V ac input setting. Step Step If 12V dc operation is required, remove the screw located at the rear of the housing. (Figure 2-1) For 24Vac operation: Power is red or black Refer to Figure 1-1 on page 8. For 12V dc operation: Power is black (GND) and red (+ dc). Refer to Figure 1-2 on page 9. Step Before closing the end, ensure the gasket is seated properly on the enclosure (flat against the edge). Close the end and tighten the screw. Step Test the illuminator for proper operation. 8
SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationTC26-B Vehicle Sensor
Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only
More informationDA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators
Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory
More informationREFERENCE MANUAL FORM: MX-TRM-E REL REV MTE
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation
More informationMatrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages
More informationASSEMBLY AND INSTALLATION INSTRUCTIONS
ASSEMBLY AND INSTALLATION INSTRUCTIONS 356-9231 / 356-9232 WARNING: NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. Customer Service: 1-800-887-6326
More informationMatrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING
Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationHATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL
HATO 120/200 SECTIONAL DOOR OPERATOR USER S 2 OUTLINE 1. Safety instructions...4 2. Description and features... 4 3. Technical specifications... 4 4. Check... 5 5. Installation and adjustment... 5 6. Programming...
More informationThe POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.
The POWER In PRESENTATION PRODUCTS Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137
More informationHigh-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES
High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES The LHP Series offers many advantages in an industrial environment LHP SERIES Illuminates wide, open areas such as warehouses, manufacturing
More informationEffective June 1, 2013 This guide supersedes all previous versions
Effective June 1, 2013 This guide supersedes all previous versions 3842 Redman Drive 1-800-797-7974 Fort Collins, CO 80524 www.commandlight.com L-CAS THANK YOU Please allow us to express a simple thank
More informationnual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual
nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual Copyright Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission
More informationLED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light scratch that. This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechelectronics.com sales@altechelectronics.com
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationCAUTION CM-SE CM-S21 CM-S41
CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and
More informationBULLETIN NO.ELEC IM121/10A Replaces IM121/09A
Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt
More informationHigh Frequency SineWave Guardian TM
High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation
More informationThe Da-Lite Difference.
The Da-Lite Difference. Instruction Book for Cosmopolitan Electrol For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationPOWERWARE User s Guide VA.
POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
More informationBattery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A
Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC-122000A AND PSC-241000A Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC
More information1329I Integrated Drive/Motor CE Filter Option Kit
Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the
More informationModel Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:
MAPA Products MPD-XX / Pedestal Disconnect 30, 60, 100 amp February 2014 Pedestal Disconnect Installation Instructions Parts List MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides
More informationCCTV Rack Mount Power Supplies
CCTV Rack Mount Power Supplies Installation Guide Models Include: Vertiline24C Vertiline24CD - or @ 10 - or @ 10 - Twenty-four (24) fuse protected outputs - Twenty-four (24) PTC protected outputs Vertiline246C
More informationLUMASTAR EPL-100 J500 INSTALLATION, OPERATING & J MAINTENANCE
Specialists in Liquid Level Indication LUMASTAR EPL-100 INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR ATEX UNITS Section: J500 Bulletin: J500.33 Date: 01-10-12 Supersedes: 09-11-06 STORAGE and
More informationInstallation Instructions
SOLAR GARDEN POWER CELL SKU#229120 Rated Voltage 12VDC Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before
More information1100 Series Piston Type Differential Pressure Gauges
1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.
More informationVA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators
VA-640GSX024P Datasheet Large Globe Actuators Overview The VA-640GSX024P Electronic valve actuators receive a 0 to 10 VDC or 4 to 20 ma control signal to proportionally control the valve. Applications
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationOPERATING MANUAL: L/S VARIABLE-SPEED MODULAR DRIVES Model Nos. Pump Drive 07559-00 with Pump Head 07516-00 07559-00 07559-05 07559-10 07559-15 A-1299-7331 Edition 01 (US & Canada only) Toll Free 1-800-MASTERFLEX
More informationVandal Resistant Ringdown/Autodialer Telephone
www.guardiantelecom.com MADE IN CANADA Industrial Communications Worldwide Vandal Resistant Ringdown/Autodialer Telephone Installation & Operation Guardian Telecom Inc. XXXXXXXX XXXXXXXX XXXXXXXX MODEL:
More information150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord
150 Watt Explosion Proof LED Flood Light - Surface Mount - 17,500 Lumens - C1D2-25ft Cord Part #: EPLC2-LED-150W-RT-JB2-25C The Larson Electronics EPLC2-LED-150W-RT-JB2-25C Explosion Proof LED Flood Light
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement
More informationTABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input
BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...5 2.1 Location and
More informationINSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.
103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com
More informationOperating Instructions
DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,
More informationSV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications
The US manufactured SV10 LED is the brightest thru hull LED underwater light available to owners of GRP and wood boats. The industry leading SV10 combines the unique qualities of the latest high density
More informationMANUAL. Single charger
MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3
More informationBMRX Series ROTARY LEVEL CONTROL
BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...
More informationModel 550 Series Vibration Switches
OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...
More informationINSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES
INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES Page 1 of 18 The PRL LED Point Rollover Light is used for heliport TLOF and FATO applications where an inset light is required. The thick soda lime glass
More informationVP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY
Issue 6 VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-6124 and VP-6124-E, 24Volt Power
More informationPan and Tilt Head CDD2416-T
Pan and Tilt Head CDD2416-T Installation guide Before attempting to connect or operate this product, please read these instructions completely Williams Electronics Ltd www.w-e.co.uk Tel: +44 (0)2921 660
More informationOperating Data Installation Maintenance Instructions. For Level Sensor. Large Multi-Level
Operating Data Installation Maintenance Instructions For Level Sensor Large Multi-Level NOTE: SSR1000 and 500 Controls have built in switch protection, time delay and low voltage power supplies. The electrical
More informationASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY
0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod
More informationSineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING
SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of
More information1100W PORTABLE GENERATOR
1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use
More informationBattery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP
Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC-124000AP OPERATING PROCEDURES AND SAFETY INSTRUCTIONS CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER NO USER
More informationSAVE THESE INSTRUCTIONS!!
IMPORTANT: Please read carefully before installation and retain for future reference To prevent possible shock hazard, the fixture should be installed by a qualified licensed electrician All electrical
More informationdv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING
dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationBMRX Series Rotary Level Indicator
BMRX Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ
More informationLED FLASHER GND CONTROL FPC4N
LED FLASHER GND CONTROL FPC4N Installation/Operations Manual FPC4N Table of Contents Applicable Models... 2 Introduction... 2 General Warnings... 2 Unpacking &Pre-Installation Check... 3 Installation &
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationUL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected
Rack Mount Series UL Listed CCTV Power Supplies Installation Guide Models Include: R615DC8UL R615DC8ULCB - 6-15VDC @ 4 amp. - 6-15VDC @ 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected R615DC416UL
More informationBattery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A
Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC-124000A OPERATING PROCEDURES AND SAFETY INSTRUCTIONS CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER NO USER
More informationinnovations in battery charging
innovations in battery charging AutomaticBatteryCharger forsealed or Valve Regulated Lead-Acid Batteries Model HPX-60 Series OperatingInstructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT
More information500 Watt Portable LED Work Area Light Cart ft cord - 60,000 Lumens V AC
500 Watt Portable LED Work Area Light Cart - 100 ft cord - 60,000 Lumens - 120-277V AC Part #: WAL-WBC-500LTL-LED-100 Page: 1 Made in the USA The WAL-WBC-500LTL-LED-100 Cart Mounted LED Work Area Light
More informationSV14 technical specifications
aluminum weld in underwater light SV14 T he Sea Vision SV14 weld in model for aluminum hulls can be installed in the transom or the hull, it utilizes a 150 watt HID metal halide lamp and 110-230 volt AC
More informationValor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur
Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS
More informationSPSR-115/230. Self-Powered Sensor
MONARCH INSTRUMENT Instruction Manual SPSR-115/230 SPSR-115/230 Self-Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com
More informationECONOMISER SERIES E2T USER MANUAL
TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014
More informationSafe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual
Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationBAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer
BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer PREPARATION Getting Started Thank you for purchasing the Dual BAK1500 compact amplified subwoofer. Although Dual has attempted to ensure
More informationSolenoid Operator 0516 / 1216
nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!
More informationDefender 3000 Series Base Instruction Manual
Defender 3000 Series Base Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compliance This product conforms to
More informationPM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.
PM500 Voltage Regulator User Manual A Regal Brand Scan here for other languages. Introduction The PM500 is an encapsulated electronic voltage regulator intended for use with Marathon Generators PMG system.
More informationNORTH CAROLINA SHERIFFS ASSOCIATION
NORTH CAROLINA SHERIFFS ASSOCIATION Name of Dealership Type of Vehicle Zone 600 AMP AUTOMATIC TRANSFER SWITCH (Specification #07) Base Unit Price 207 ASCO AC600 Appalachia -- NB -- 207 ASCO AC600 Dogwood
More informationAIM LED LIGHT (wall mount)
AIM LED LIGHT (wall mount) Installation Manual AIM LED LIGHT (wall mount) INTRODUCTION Lights in the AIM Series are designed to give the professional health care market superior performance, reliability
More information150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B
150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B Part #: HBLP-REMG-1MLED-B-PND Page: 1 Made in Texas The Larson Electronics HBLP-REMG-1MLED-B-PND LED
More informationEXP Scaffold Mount LED - Remote Mount Emergency Backup - Day/Night Sensor - C1D1 & C2D1-150' Cord
EXP Scaffold Mount LED - Remote Mount Emergency Backup - Day/Night Sensor - C1D1 & C2D1-150' Cord Part #: EPL-JH16C-1MLED-150C-XEMG-XDNS-10C Made in the USA The EPL-JH16C-1MLED-150C-XEMG-XDNS-10C Explosion
More informationElectric Actuator Instructions
BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5
More informationRecommended Tools: Phillips Screwdriver, Flat Blade Screwdriver, 13mm and 10mm Wrench, 5/16 nut driver,
UPS-ST-120 UPSPro Outdoor UPS System Wireless Base Stations and Client Devices Surveillance Cameras Mission Critical Backup Power Remote Sensors Congratulations! on your purchase of the UPSPro Outdoor
More informationBUSWAY Low Voltage (Pow-R-Flex)
BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and
More informationSolenoid Operator 0513 / 1213
nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In
More informationISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)
ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions
More informationUsage Instructions of Solar Control for 3Way-Ball Valve
Table of Contents: Page: 2 Safety Instructions 3 Intended Use / General / Warranty / Installation: 4 Schematic Diagram: Mounting the sensor 5 Start-UP 6 Note: 7 Electrical connections: Technical Specifications
More informationPS-1X Series Power Supply Unit Information & User Manual
PS-1X Series Power Supply Unit Information & User Manual AC to DC Power Supply Unit for Motion Control Applications Model No s: PS-1X0 and PS-1X2 Ultra Motion PSU Manual 1 Safety Information IMPORTANT:
More informationAIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:
AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual
More informationPOWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR
User s Manual for The POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR 301 Gaddis Boulevard Dayton, Ohio 45403 U.S. Toll Free 866-261-1191 (937) 253-1191 Fax: (937) 253-1723 Web site: www.stacoenergy.com
More informationOperating Instructions for Oval Wheel Flowmeter. Model: DOC
Operating Instructions for Oval Wheel Flowmeter Model: DOC We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document
More information56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof
56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications - 7000 Lumens - IP67 Waterproof Part #: GVP-48-2L-LED Page: 1 The Larson Electronics GVP-48-2L-LED is similar to our popular explosion proof
More informationThe Da-Lite Difference.
The Da-Lite Difference. Instruction Book for Large Advantage Electrol DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737
More informationDeclaration of Conformity
We Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. No. 7-1, Jhongsing Rd, Tucheng City, Taipei County 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District
More informationLED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechefficiency.com sales@altechefficiency.com Specifications
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationA Member of the. Integrated Metering Technologies
I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe
More information150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1
150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1 Part #: EPLC2-JHM-150LED-RT-100-EPP The EPLC2-JHM-150LED-RT-100-EPP from Larson Electronics is an Explosion
More information1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket
1000W High Intensity LED Crane Light - 110,000 Lumens - 347-480V AC - Stainless Steel Bracket Part #: GAU-HB-1000W-LED-SS-480V Page: 1 The GAU-HB-1000W-LED-SS-480V from Larson Electronics is an LED Crane
More informationHeavy Duty Series (HDS) Installation and user guide
Heavy Duty Series (HDS) Installation and user guide HDS20-50 HDS20-100 (2x50 Watt transducers) (2x100 Watt transducers) www.shipsonic.com a brand of: delta-sistems BV Blokjesplaat 1 4465 BC Goes The Netherlands
More informationMD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version
MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty
More informationSERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL
SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown
More information7W Explosion Proof LED Drop Light - C1D1 - Transformer Steps Down 240VAC to 12VDC - 50' SOOW
7W Explosion Proof LED Drop Light - C1D1 - Transformer Steps Down 240VAC to 12VDC - 50' SOOW Part #: EHL-LED-240X12V-XGFI-50 Made in the USA The Larson Electronics EHL-LED-240X12V-XGFI-50 Explosion Proof
More informationELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS
ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4
More informationInstallation Guide. FOR TECHNICAL ASSISTANCE, VISIT
Installation Guide The HG2 Runner Package is an extremely versatile emergency lighting system designed for maximum visibility with a minimal footprint. HG2 Runners were developed to enhance the outline
More informationTS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc
TS400Q TS800Q Auto Pressure Control Pump Instruction Manual ISO 9001 Certified Walrus America Inc EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih
More informationSPSR-115/230. Self-Powered Sensor
MONARCH INSTRUMENT Instruction Manual SPSR-115/230 SPSR-115/230 Self-Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com
More information- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
ALTV248 Series CCTV Power Supplies Installation Guide Models Include: ALTV248 ALTV248CB - @ 4 amp (100VA). - @ 4 amp (100VA). or @ 3.5 amp. or @ 3.5 amp. - Eight (8) Fuse Protected s. - Eight (8) PTC Protected