1 Heavy Duty Series (HDS) Installation and user guide HDS20-50 HDS (2x50 Watt transducers) (2x100 Watt transducers) a brand of: delta-sistems BV Blokjesplaat BC Goes The Netherlands info@shipsonic.com
2 Contents Delivery... 3 Parts list... 3 System dimensions and weights... 3 Product overview outside... 4 Product overview inside... 6 System identification... 7 Installation... 8 Planning... 8 Installation of the control-unit... 8 Installation of the transducers... 8 Transducer cables... 9 Activation... 9 Schematic electrical diagram... 9 Maintenance checklist... 9 Troubleshooting Technical support and after sales service Contact CE certification Page 2 of 11
3 Delivery Inspect the shipping crate for exterior damage and if necessary bring this to the attention of the freight carrier. Unpack the crate immediately after delivery. Inspect if the contents comply with the packing list from your local agent or Shipsonic Check the contents for damage Open the control-unit and inspect the interior for loose and/or damaged parts. Inspect cable fittings to transducers and IP68 connectors. If any damage is found, please file a concealed damage claim with the Freight Carrier within 24 hours of delivery. Only the consignee can file a damage claim. Keep the damaged shipping crate until the carrier s representative has inspected it. If necessary, contact your local agent or Shipsonic for further assistance. Parts list For a complete parts list, please refer to the technical documentation inside the control cabinet. System dimensions and weights Part Dimensions Weight Cabinet H x W x D = 300 x 300 x 155 mm 13 kg Transducers-100-Watt -Water-resistant-PVC-housing -Water-proof-POM/stainless-steel-housing -Water-proof-POM/stainless steel-housing-support H x = 86 x 74 mm H x = 78 x 86 mm H x = 126 x 90 mm 750 grms 1035 grms 1350 grms Page 3 of 11
4 Product overview outside Front exterior of HDS20 The HDS series is mounted in a cabinet with rubber door seal and safety lock with removable key. The red/yellow on/off emergency power switch (110/240 AC) can be locked in the off position. The blue signal lamps (1,2) indicate individual power circuit board (PCB) actuation. The blue illuminated push switches (1,2) actuate the individual PCBs. Page 4 of 11
5 Bottom exterior of HDS20 To the right the AC power cable inlet, and to the left 2 TH381 2 pole transducer connectors. Side panel of HDS20 Side panel with 2 ventilators (Note that the ventilators are mounted at opposite sides, one blowing inward and one outward to enhance cooling air circulation in the cabinet) Page 5 of 11
6 Product overview inside Interior of HDS20 On top 2 Mean Well power supplies, below the Power Circuit Boards (PCB). Each transducer has an individual power supply and PCB. Each PCB has 2 2-color LED indicators; green for power on and red for blown fuse. In the picture, the left PCB has a blown fuse (demonstration purposes only), the right PCB is functioning properly. Power supplies, PCBs, activation buttons, indicator lights and transducer connectors have corresponding numbers. WARNING: High voltage and high capacitance is present in Shipsonic HDS ultrasonic systems. Only qualified electricians are permitted to work on this equipment. Page 6 of 11
7 Interior cabinet door of HDS20 Cabinet door with seal, separate grounding, push buttons, indicator lights, power switch and system identification sticker. System identification Digits of the information on the identification sticker: Type: HDS X0 - XXX Wattage of transducers Number of transducers Serial: HDS X0 - XXX-XX-XX Serial number in year of manufacture Year of manufacture Wattage of transducers Number of transducers Date: day-month-year Page 7 of 11
8 Installation Planning Plan the layout of your complete system. Position the control-unit such that engine room staff can check the indicator LEDs regularly. Do not locate it too far from the box-cooler, plate-cooler intake or any other object that you want to protect form fouling. Standard the transducers are equipped with 10 meter cables. Make sure the control-unit is within reach of a suitable electrical source (earthed). Installation of the control-unit Identify a suitable location for the control-unit: Clean and dry Well ventilated Ambient temperature of -10 C (14 F) and 50 C (122 F) Protected from airborne particulate, moisture and dirt. Mount the control-unit using the enclosed mounting brackets and optionally vibration absorbing mounting feet and connect the power cable to a dedicated VAC 16 ampere, single-phase outlet with grounding. Example of vibration absorbing mounting feet Incoming power must be free of any power surges or spike' greater than 15% of rated voltage i.e.: 110 VAC with a maximum of 126 VAC 240 VAC with a maximum of 276 VAC (spikes < 0.5 seconds in duration) Installation of the transducers Delta-sistems offers different types of transducers: 100 Watt, 28 KHz series -water resistant, PVC housing, direct glue or aluminum bracket installation -water proof, POM and stainless steel 316 housing, direct glue installation -water proof, POM and stainless steel 316 housing, installation with stainless steel 316 support Page 8 of 11
9 50 Watt, 40 KHz series -water proof, POM and stainless steel 316 housing, direct glue installation -water proof, POM and stainless steel 316 housing, installation with stainless steel 316 support You will find the transducer installation manual -for the specific transducer type you have chosenattached to this manual. Transducer cables Standard transducer cables have a length of 10 meter. In your order you might have specified a different length. Conduct the transducer cables between transducer and control-unit out of harm's way, using tie-wraps as deemed necessary. Do not roll up spare transducer cable into a tight service loop; a tightly rolled loop might start functioning as a spool and interfere with the working of the transducer. Activation Connect the transducer cables to the connectors at the underside of the control-unit using the IP68 connectors. It is not possible to mix up the polarity with these connectors. 2 pin Techno IP68 connectors Connect the control box to a Volt power outlet if you had not already done so. Turn on the main power red/yellow emergency power switch. Power on the transducers one by one through the blue push button switches. The blue illumination of the push button should come on permanently. The blue indicator light for each transducer should start blinking. If possible check if you can hear a light ticking sound coming from each transducer. Your system is now functional. Schematic electrical diagram For a detailed electrical diagram please refer to the technical documentation inside the control unit. Maintenance checklist Your ultrasonic antifouling system does not need regular maintenance. Just check the following minor items regularly: -Check the functioning of both cooling fans in the cabinet Page 9 of 11
10 -Check to ensure that the cooling fan intake openings are clear and free from obstructions -Check the inside of the cabinet and remove dust and particles once per month -Check the installation of the transducers. If a transducer has come off, re-install applying the steps under 'Installation of the transducers' again. Troubleshooting Step 1: A blue LED does not blink If a transducer is not working properly, the blue indicator light on the cabinet door will stop blinking. If this happens, open the cabinet door and mark which PCB does not have its green LED on. This PCB will probably have the its red LED on. Then switch off all transducers one by one and remove 240 VAC from the cabinet. Now disconnect the concerned transducer from the control cabinet. Step 2: The fuse Check the fuse of the affected PCB. If it is blown, replace it with a T6A, reapply 240 AC and check the functioning of the PCB through the blue blinking light on the cabinet door. If it does start blinking normally, the PCB is fine and the problem is the transducer. Proceed to step 3. If the PCB does not start blinking normally (the fuse might trip again), proceed to step 4. Step 3: Check the transducer Using a multi-meter, check resistance between pin 1 and pin 2 on the male (cable-end) IP68 connector of the affected transducer. Resistance should be 1. If it is not 1, there is a short circuit in the transducer or in the wire. Check the wire for damages, and if possible, take out the damaged part. If the wire is not damaged, replace the transducer with cable with a new one. The inner parts of the transducer are not serviceable. If wire and transducer are in order (resistance between pole 1 and pole 2 is 1), check its functioning again by plugging in this transducer into a different connector on the cabinet and check functioning. It should function normally. Now you know the PCB is the problem, proceed to step 4 Step 4: Replace the PCB If the fuse trips again and the transducer has been checked as described under step 3, replace the entire PCB. On the PCB, pull off the green connectors (do not remove the wires from the green connector itself). Loosen the 4 screws on the corners of the PCB and pull out the PCB. Install the new PCB by applying the steps in reverse order. Close the cabinet and power on the affected PCB. If the problem persists, contact your dealer or Shipsonic directly. Note: A short circuit in the transducer or the transducer wire makes the fuse trip, but it often also results in damage to the PCB. In other words, if a PCB is not functioning (damaged), normally a short circuit in the transducer is the cause. If you plug this transducer into another connector on the control cabinet, you might damage another PCB. Page 10 of 11
11 Technical support and after sales service Technical support is available through or directly by telephone from your local dealer or from Shipsonic. When calling, please be prepared to provide the information on the identification sticker on the inside of the cabinet door of the control-unit. Requests for parts can also be placed by phone or sent by to your local agent or Shipsonic. If a system needs to be returned for repair, contact your local agent or Shipsonic directly. We will arrange the repair and/or eventually the exchange of the system. Shipsonic pays for all repairs/replacements within the warranty period (1 year). Outside that period, your agent and/or Shipsonic will decide on a case by case basis what to do and whom will bear the costs. Contact For any additional information contact your local agent. Otherwise, contact the producer of Shipsonic systems directly: delta-sistems info@delta-sistems.nl Goes, The Netherlands CE certification All our products are in conformity with the essential requirements of directives 2004/108/EC (Electromagnetic Compatibility) 2011/65/EC (RoHS Directive) and 2006/95/EC (Low Voltage Directive) and their subsequent amendments of the European Parliament and Council. CE - test done in accordance with the company: Globus Benelux Hattem The Netherlands: CE - test ultrasonic anti fouling systems, under the following test norm: NEN-EN IEC ELECTROMAGNETIC COMPATIBILITY (EMC)-PART 6-4 GENERIC STANDARDS EMMISION STANDARDS FOR INDUSTRIAL ENVIRONMENTS: (IEC :2006/A1;2010,IDT) All modifications reserved Page 11 of 11
Heavy Duty Series (HDS) Installation and user guide
Heavy Duty Series (HDS) Installation and user guide HDS40-50 HDS40-100 (4x50 Watt transducers) (4x100 Watt transducers) www.shipsonic.com a brand of: delta-sistems BV Blokjesplaat 1 4465 BC Goes The Netherlands
More informationUSER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE
USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE SECTIONS: ENGLISH 2 NEDERLANDS 17 DEUTSCH 37 Victron Energy BV De Paal 35 1351 JG Almere-Haven The Netherlands Article number
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationThe Powermatic User Guide Test Sieve Shaker
The Powermatic User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3-4 Levelling 4 Electrical Connections 5 Sieve Stacking 6-8 Operating Instructions
More information36 HYPER MAX DIRECT DRIVE GALVANIZED BOX FAN
Assembly & Installation Manual Read carefully the information provided. Retain manual for future reference. 36 HYPER MAX DIRECT DRIVE GALVANIZED BOX FAN IS10063.DOC Step 1 Unpack and become familiar with
More informationLED AR111 Instruction Manual
LED AR111 Instruction Manual *Technical Information* The alternative LED module to AR111 halogen reflector lamps 50/75W Tender text Designed to fit into standard AR111 fixture Use 6 high power LEDs Available
More informationXENON POWER SUPPLY 4000 Watt Gladiator IV
XENON POWER SUPPLY 4000 Watt Gladiator IV 220 Volt Equipment Type 62-00049 Rev. February 2003 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationWF-5100 Series True Sine Wave Inverters
Operator s Manual WF-5100 Series True Sine Wave Inverters WF-9900 Series WF-5118 WF-5120 ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada
More informationGo Power! Manual. GP-1750HD Inverter GP-2500 Inverter
Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...
More informationHQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual
HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter User Manual Important Safety Instructions Please read the installation and operating instructions in this manual carefully before using your
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has
More informationAC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters
AC Anywhere Power Inverter (Class II product) F5C412uk140W F5C412uk300W User Manual F5C412uk140W, F5C412uk300W Please read the installation and operations instructions before using the Power Inverters
More informationSITESTAR ELECTRONICS CABINET DESCRIPTION
SITESTAR ELECTRONICS CABINET DESCRIPTION SiteTel Sweden AB Haukadalsgatan 8A, SE-164 40 Kista, Sweden www.northstarbattery.com Contents 1 INTRODUCTION... 4 1.1 TARGET GROUP... 4 1.2 DOCUMENTS... 4 1.3
More informationPhoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
More informationGP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:
Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS
More informationGSL Electronics Modified Sine Wave Power Inverters
GSL Electronics Modified Sine Wave Power Inverters Congratulations on choosing one of our Modified Sine Wave Inverters for your application. There are 6 models in the range, which will meet most of your
More informationUser Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply
More informationIQL Helios Area-/Streetlight. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...
More informationOutdoorXUPS-600AHV-8364
OutdoorXUPS-600AHV-8364 TSi Power s OutdoorXUPS-600AHV-8364 provides secure and uninterrupted 230 vac power to critical loads. 1) Weather-tight metal cabinet (IP44 or NEMA 3R rated) 2) 2A and 2B are wide
More informationMODEL H INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your unit has been carefully packaged at the factory to prevent damage during shipping.
More informationMV Series Motors Operation & Parts Manual
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson
More informationMeasurements are expressed in millimeters.
T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164
More informationPURE SINE WAVE DC TO AC POWER INVERTER
PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read
More informationInstallation Guide The RSi brief overview:
Electronic Rust Protection Installation Guide The RSi brief overview: The RustStop RSi Industrial uses a 6 channel output system to drive up to 18 anodes (Rust Magnets ) Each channel has its own output
More informationAIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:
AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual
More informationMatch 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.
Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
More informationUser Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work
GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS AR24 REMOTE CONTROLLED SURGICAL LIGHT TEC-B-0022 REV5 1/14 Page 1 EQUIPMENT LABELS AND SPECIFICATIONS ATTENTION, CONSULT MANUAL FOR FURTHER INSTRUCTIONS. INDICATES SPECIAL USER
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More information1100 Series Piston Type Differential Pressure Gauges
1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.
More informationEMERGENCY VEHICLE BATTERY MANAGER PS2024
EMERGENCY VEHICLE BATTERY MANAGER PS2024 2 The PS2024 (Fig. 1) is designed as a on-vehicle battery charger / battery charge state monitor. While the vehicle is at its base or station, the charger is connected
More informationHPP1 MK5 Owner s Manual
J Wolmarans Page 1 2017/03/07 Page 1 of 10 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Features...3 5 Contents...3 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible
More informationw w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual
w w w.apc.com Home Appliance & ighting UPS HI800SQ Installation Guide and User s Manual 990-2391D Copyright 2009 American Power Conversion. All rights reserved. APC is a registered trademark of American
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY. MODEL MP-3913 WITH MP-2002 Control
OPERATING INSTRUCTIONS AND SERVICE MANUAL BMX DISPLAY MODEL MP-3913 WITH MP-2002 Control EFFECTIVE S.N. 18225 May 6, 2002 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification 1.3
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationInstallation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System
Installation and Operation Guide Tundra HD 2500 Power Inverter for the Webasto BlueCool Truck System www.tundrainternational.com www.techwebasto.com BCTSP0063A Table of Contents 1. Introduction 4 1.1 Disclaimer.................................................................................
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER. MODEL MP-3905 WITH MP-2002 Control
OPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER MODEL MP-3905 WITH MP-2002 Control EFFECTIVE S.N. 17155 May 18, 2001 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification
More informationHyperFlex 12G.
HyperFlex 12G USER MANUAL www.venuelightingeffects.com Table of contents Introduction...2 safety precautions...3 UNIT OVERVIEW...4 rigging the fixtures...4 Lamp Installation/Replacement...5 gobo Selection
More informationOPERATION INSTRUCTIONS
www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech
More informationGo Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4
Table of Contents 1. INTRODUCTION... 3 Go Power! Manual GP-SW1500 Inverter 2. SPECIFICATIONS... 3 3. NAME AND MAIN FUNCTION... 3 4. INSTALLATION... 5 5. OPERATION... 7 6. OPERATING LIMITS... 9 7. TROUBLESHOOTING...
More informationDC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL
DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL 1 A. INTRODUCTION The AIMS Power pure sine inverter product line is used for back-up power. The pure sine product line is ideal for sensitive
More informationLED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR
INTRODUCTION The LED AC Driverless Floodlights with PIR include a hanging / mounting bracket and a 100cm cable. SPECIFICATION LED 800-4000lm IP65 180-240V IK07 6000K 50Hz >80 Ra 10W- 50W Dimensions: FLAC10BPIR:
More informationLED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechefficiency.com sales@altechefficiency.com Specifications
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3903 TIMER
OPERATING INSTRUCTIONS AND SERVICE MANUAL MODEL MP-3903 TIMER EFFECTIVE S.N. 16,600, FEB. 28, 2001 1. General Information TABLE OF CONTENTS 1.1 Description 1.2 Identification 1.3 Damage 1.4 Damage Claim
More informationLARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions
LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions GENERAL 2 Inspection 2 Location 2 INSTALLATION 2 Door Alignment 2 Shelf Installation 2 Remote Contacts 2 2-10 Volt DC Output
More informationHPP1 MK5 Owner s Manual
J Wolmarans Page 1 2016/09/15 Page 1 of 9 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Contents...3 5 Installation...3 5.1 Mounting the unit:...3 5.2 Connecting the battery:...3
More informationDIGITAL TEMPERATURE CONTROL
Fridge / Freezer / Warmer with DIGITAL TEMPERATURE CONTROL MODEL MHD13F-DM SPECIFICATION DESIGNATION OF PARTS MODEL CAPACITY OUTER DIMENSIONS INPUT RATING ( or FREEZER) (WARMER) REFRIGERANT WEIGHT MHD13F-DM
More informationMass Sine 24/10000 Mass Sine 24/15000
USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342
More informationWF-5110R True Sine Wave Inverter
Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION
More informationPan and Tilt Head CDD2416-T
Pan and Tilt Head CDD2416-T Installation guide Before attempting to connect or operate this product, please read these instructions completely Williams Electronics Ltd www.w-e.co.uk Tel: +44 (0)2921 660
More informationUser Guide for Logo Projector
User Guide for Logo Projector Professional Entertainment Technology . TABLE OF CONTENTS 1. Introduction 2. Safety Instruction 3. Description 4. Operation and Technical Specification 5. Lamp Installation
More informationHigh Profile Evaporator
High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost
More informationLED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light scratch that. This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechelectronics.com sales@altechelectronics.com
More informationH-2034, H-2035 SHRINK TUNNEL
H-2034, H-2035 SHRINK TUNNEL SPECIFICATIONS IMPORTANT! Read this manual thoroughly and familiarize yourself with ALL controls and operating features. Keep this manual for future reference and maintenance.
More informationOPERATING INSTRUCTIONS AND SERVICE MANUAL PRODUCTION COUNTER. MODEL MP-3911 WITH MP-2002 Control
OPERATING INSTRUCTIONS AND SERVICE MANUAL PRODUCTION COUNTER MODEL MP-3911 WITH MP-2002 Control EFFECTIVE S.N. 17255 September 13, 2001 TABLE OF CONTENTS - 1. General Information 1.1 Description 1.2 Identification
More informationThe EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents
The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating
More informationTREE ASSEMBLY INSTRUCTIONS
TREE ASSEMBLY INSTRUCTIONS The Oldest Family Name for Christmas Trees in America SAVE THESE INSTRUCTIONS! - 1 - Table of Contents 1. Important Safety Notes Page 3 2. Attention Page 4 3. Getting Started
More informationCLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual
CLEAN AIR WORKSTATION REVERSE FLOW Installation and Operations Manual CLEAN AIR WORKSTATION REVERSE FLOW Installation and Operations Manual Revision: 16-Jan-17 Page 1 of 12 CLEAN AIR WORKSTATION REVERSE
More informationO W N E R ' S M A N U A L
1500 Watt DC to AC Power Inverter C o n v e r t s 1 2 V D C B a t t e r y P o w e r t o 1 1 0 V A C H o m e P o w e r O W N E R ' S M A N U A L SAVE THESE INSTRUCTIONS The recommended source of power is
More informationC.fm Page 1 Thursday, February 21, :28 AM Raptor user manual
Raptor user manual 1 mounting bracket 2 swivel lock 3 clamp hole 4 lamp access screws 5 air vents 6 AC input & main fuse 7 cooling fan Thank you for selecting the Martin Raptor. This Martin lighting fixture
More informationC RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
C RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire England
More informationModel: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power
OWNER S MANUAL Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationOwner s Manual. PowerVerterDC-to-AC Inverter
Owner s Manual PowerVerterDC-to-AC Inverter Model: PV700HF Input V DC Output 0V, 60Hz AC Reliable AC Power Wherever You Need It Congratulations! You've purchased a high-quality Inverter designed to function
More informationOperator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)
Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION Warranty Service
More information3. Operating instructions: Minor 200
1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200
More informationPure Sine Wave Inverter GP-HS1500. Owner s Manual
Pure Sine Wave Inverter GP-HS1500 Owner s Manual 2 Table of Contents Introduction 3 Specifications 4 Name and Main Function 5 Installation 7 Operation 9 Operating Limits 13 Troubleshooting 13 Maintenance
More informationSingle Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25
V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationWELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04
WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...
More informationHPP1 MK6-15A/20A R00 Owners Manual
J Wolmarans Page 1 2018/10/23 Page 1 of 7 TABLE OF CONTENTS Page 1 Introduction...2 2 Model...2 3 Safety warnings...2 4 Contents...2 5 Features...2 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting
More informationModel 1693, 1694 Switching DC Power Supply
Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases
More informationModel and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS
Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact
More informationPHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC
PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC 1 DANGER: HIGH VOLTAGE Electric shock could result in death or injury. qualified personnel for installation. Please
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationDESIGN-AIRE SL-RSR-EC. Installation and Operations Manual
DESIGN-AIRE SL-RSR-EC Installation and Operations Manual DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 28-Jan-16 Page 2 of 15 DESIGN-AIRE SL-RSR-EC Installation and Operations Manual
More informationCaddy. Tig 2200i AC/DC. Instruction manual GB Valid for: serial no. 711-, 747-xxx-xxxx
Caddy Tig 2200i AC/DC Instruction manual 0460 225 301 GB 20180920 Valid for: serial no. 711-, 747-xxx-xxxx TABLE OF CONTENTS 1 SAFETY... 4 1.1 Meaning of symbols... 4 1.2 Safety precautions... 4 2 INTRODUCTION...
More informationCALTRAP INSTALLATION AND OPERATIONS MANUAL
INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.
More informationV 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual
DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual Introduction The AIMS Power 5000 Watt series inverters are the most advanced line of mobile DC to AC power
More informationSBC / 2140 / Stage Battery Charger User Manual
SBC - 2130 / 2140 / 2150 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationInstallation, Operation and Maintenance Manual. EVC Controller (from February 2007)
Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions
More informationPRODUCT OPERATING MANUAL
PRODUCT OPERATING MANUAL PANBLAST TM CS37 SUCTION BLAST CABINET Manual Number: ZVP PC 0069 00 SECTION 1. GENERAL INFORMATION 2. ASSEMBLY & INSTALLATION INSTRUCTIONS 3. OPERATING INSTRUCTIONS 4. MAINTENANCE
More informationOperators Manual. Recirculating Chiller /06/08
Operators Manual Recirculating Chiller 110-197 11/06/08 Table of Contents Section 1. General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description of the Recirculating Chiller 1.5
More informationSingle Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100
V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane
More informationThe Power of Reliability INSTRUCTION MANUAL
The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects
More informationAsynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors
Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors Series R2, Frame 63 355 Introduction KHM R2 series cast iron motors are totally enclosed fan cooled, 3 phase, and squirrel cage induction
More informationX100P Load Bank. Read all instructions before using the load bank. Contents
X100P Load Bank Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a) X100P Load Bank... 4 3) Receiving... 4 4) Safety... 5 a) Grounding...
More informationSPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1
SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL Issue No: 1 Certificate No: 0954499 CE Marking certifies that this equipment conforms to the following EEC directives: - Low Voltage
More informationA3Z OPERATING MANUAL
A3Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...
More informationUser Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736
User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationXENON POWER SUPPLY Watt
XENON POWER SUPPLY 3000-5000 Watt 220 Volt Equipment Type 62-00016 62-00017 62-00004 (Export) Rev. February 2006 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha,
More informationEC MACHINE DIRECTIVE COMPLIANCE DECLARATION
770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the
More informationDelta HE 35-XX, 55-XX
Installation and Operating Instructions Delta HE 35-XX, 55-XX 10.2009 Table of contents Table of contents EC Conformity Declaration Technical Data Delta HE 35 Technical Data Delta HE 55 Mounting Instructions
More informationMRC 150/300 USER MANUAL. 1 Laird Technologies
MRC 150/300 USER MANUAL 1 www.lairdtech.com Laird Technologies THR-UM-MRC150-300 0912 Americas: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 clv.customerpos@lairdtech.com 2 www.lairdtech.com
More informationA6Z OPERATING MANUAL
A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS 05/14 iss 4 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More information