Geberit Assisted Toilet Pre-Installation Instructions

Size: px
Start display at page:

Download "Geberit Assisted Toilet Pre-Installation Instructions"

Transcription

1 Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried out by a qualified electrician. AC Power to be tested and available in advance of OpeMed engineers arrival. All flooring must be level and complete. All walls must be decorated and complete. Information: The factory setting for the seat height is 42.5 cm. If you wish to use this height, proceed to step B. If the customer wishes the seat height to be different from the factory setting, proceed to step A V ESD 3 Please note: 87 1 Cold water supply can be placed anywhere in the specified area Fused 2 Fuse Spur can be installed outside of the toilet however, distance is limited as there is only 700mm flex (see pages 3-5). Please always ensure the fuse is positioned above the water supply pipe. 140mm If the soil / waste pipe is positioned through floor, ensure 140mm from centre of pipe to wall (see page 2). Waste pipe can be 90mm or 110mm. 1

2 Waste PIpe:- The Diagram below shows the positioning of the waste outlet. 1 Only for sideways soil connection: Outlet bend can also be fitted in a Left or Right position. ø 12 mm Determine the height of the outlet pipe with the seat height: Select the appropriate dimension for Y depending on the set frame height. D (14 28) D = X = D = X = x 18 Y H Y

3 Electrical Connection:- The Geberit AquaClean requires a 230V AC 50Hz power supply. The power connection must be made in an area that is kept free from moisture or connected via a IPX4 waterproof socket with isolation switch be decorated and complete. The Diagram below shows the recommended positioning of the IP rated fuse. The electrical connection of Geberit AquaClean may only be installed by skilled persons in accordance with the local regulations. The following recommendations apply according to DIN VDE : The country-speciþc conditions for Austria and Switzerland are taken into account therein. Installation in rooms with bath tub or shower tray - The Geberit AquaClean models correspond to protection degree IPX4 and may only be installed outside of the edge of the tub or tray Protection area around the bath tub Protection area around the shower tray 1. Hidden connection IPX4 a) with unswitched b) with Þxed connection via junction box (at least IPX4, Geberit AquaClean may be closer than 60 cm to the edge of the tub or tray) 3

4 2. Visible connection Geberit AquaClean complete solution Geberit AquaClean enhancement solution Installation in rooms with showers without tray - The power outlet has to be installed outside the protection area. Protection area around the shower without tray (with Þxed fixed shower head) Protection area around the shower without tray (with ßexible flexible hose) ³ cm ³ cm Geberit AquaClean complete solution Geberit AquaClean enhancement solution 4

5 Geberit AquaClean in the protective area Approach: Construct a Þxed shower partition with a height of 225 cm between shower and WC system. This will mean that the WC system is outside the protective area. Non-conforming installation of the Geberit AquaClean models will then be possible. *In the case of shower partitions with heights less than 225 cm, the the minimum distance in in horizontal (encompassing radius) and vertical (thread measure) direction must be maintained. ³ ³ 225* a) Minimum distance, horizontal b) Minimum distance, vertical 5

6 Product data sheet Technical data Protection class Protection degree Nominal voltage Mains frequency Power consumption Power consumption standby / with heating switched on Cable length Flow pressure 1 Operating temperature Water temperature, adjustment range I IPX4 230 V AC Hz 1000 W 1/9 W 0.7 m -10 bar 1 bar C C Water temperature, factory setting 37 C Dryer temperature, factory setting 45 C Flush volume, factory setting 6 and 3 l Spray time 2 Maximum load WC seat Scope of delivery 0.13 l/s 0 s 150 kg Water supply connection set with angle stop valve, reinforced braided hose and screw connection Spray shield Nozzle cleaner, 400 ml Cleaning set Connection set for WC, 9 0 mm Cover plate for remote control compartment Remote control with LC display, wall-mounted case and batteries, LR03 (AAA ) Fastening material Article Art. no Colour / Surface white alpine This product is supplied with the Geberit AquaClean nozzle cleaner and the Geberit Information, instructions and measures for handling hazardous substances safely can be found in the appendix or at Accessories Accessory overview: Water supply and electrical connection for Geberit concealed cisterns 6

Geberit Concealed cisterns

Geberit Concealed cisterns Factory setting Description Front actuation 12 cm thick cm thick 6/3l for Geberit Sigma actuator plates Page 4 /3l for Geberit Delta actuator plates Page 6 6 / 3 l for Geberit Sigma actuator plates Page

More information

Clos-o-Mat Lima Lifter installation & user guide

Clos-o-Mat Lima Lifter installation & user guide Clos-o-Mat Lima Lifter installation & user guide design manufacture supply install service recycle Technical data General specifications 1 Technical data 1.1 General specifications 2 Technical data Operating

More information

7. Geberit Exposed Cisterns

7. Geberit Exposed Cisterns 7. 7.1 Expose cisterns for WCs...128 7.1.1 Close-couple... 128 7.1.2 High-level... 129 7.1.3... 13 7.2 Flush pipes for expose cisterns...133 7.3 ccessories...136 7.3.1 Connections... 136 7.3.2 ngle valves...

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

cover plate Instructions for Use suitable for Viega Eco Plus universal shower WC element, model from 08/2015 en_int

cover plate Instructions for Use suitable for Viega Eco Plus universal shower WC element, model from 08/2015 en_int cover plate Instructions for Use suitable for Viega Eco Plus universal shower WC element, model 8161.20 Model Year built: 8040.19 from 08/2015 en_int cover plate 2 from 14 Table of contents Table of contents

More information

Ropox Shower & Changing Bed

Ropox Shower & Changing Bed Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,

More information

Systems for Wall-Hung Toilets, Pre-Wall, 2x6 Installation

Systems for Wall-Hung Toilets, Pre-Wall, 2x6 Installation GEBERIT INSTALLATION SYSTEMS Geberit Installation Systems Systems for Wall-Hung Toilets, Pre-Wall, 2x6 Installation Geberit Duofix Carrier, Model No. Description List Price 111.012.00.1 Carrier frame with

More information

Operating Instruction for Downlights

Operating Instruction for Downlights Operating Instruction for Downlights Type: ES_T4_1027_SILVER/ ES_T5_1027_WHITE/ ES_T6_1017_SILVER/ ES_T7_1017_WHITE/ ES_T8_1047_SILVER/ ES_T9_2019_WHITE/ ES_T10_1044_SILVER Index 1. General safety information...

More information

Sanitary systems. TECElux TECHNICAL GUIDELINES

Sanitary systems. TECElux TECHNICAL GUIDELINES Sanitary systems TECElux TECHNICAL GUIDELINES 1-2 Contents TECElux Introduction 1-4 Design 1-4 Advanced features 1-5 Product range 1-6 TECElux module 1-8 Upper glass facings with actuation unit 1-10 Lower

More information

HOSPITAL & PROFESSIONAL. Equipment

HOSPITAL & PROFESSIONAL. Equipment Equipment Hospital & Professional Wall-Hung Hospital Scrub with high upstand 0711230001 700 mm 80 445 0711220001 1400 mm 0711240001 2100 mm 715 620 50 120 415 730 365 365 Wall-hung hospital scrub with

More information

Universal flushing cisterns for front operation date of production since 09/2007, for large toilet operation panel: Model F 102, F 106, F 500, F 502

Universal flushing cisterns for front operation date of production since 09/2007, for large toilet operation panel: Model F 102, F 106, F 500, F 502 re- and In-Wall Installation Universal flushing cisterns for front operation date of production since 09/2007, for large toilet operation panel: Model F 102, F 106, F 500, F 502 Model F 102 Ref.No. 3307xx

More information

Electronic Bidet Seat

Electronic Bidet Seat Electronic idet Seat Powered bytoto Installation Guide efore installation, be sure to read this installation guide and the separate safety sheet. Mount parts properly according to the instructions. Precautions

More information

SECTION LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY

SECTION LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY SECTION 11110 LAUNDRY WASHER-EXTRACTOR, 100 LB. (45.4 KG) CAPACITY PART 1 GENERAL 1.01 SECTION INCLUDES: A. Automatic laundry washer-extractor for processing water-washed linen items 1.02 SYSTEM DESCRIPTION

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Electric Bathroom Accessories

Electric Bathroom Accessories www.ebon.com.hk Electric Bathroom Accessories Electric Towel Rails Electric elements have a built in thermostat and internal cut out ensuring safety. The TR Series perfects simplistic design and practicality.

More information

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS ACTUATOR LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 170 air damper actuator is designed to be fitted to multi-stage or modulating oil and

More information

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide Infrared Control Valve Installation Guide Supplied Parts 1. Sensor Unit 2. Solenoid Valve 3. Mounting Bracket (for cavity walls or ceiling tiles) 4. Remote Valve Plug & Gasket 5. Mounting Screws M3.5 x

More information

Infrared Control Valve Installation Guide

Infrared Control Valve Installation Guide Infrared Control Valve Installation Guide Supplied Parts 1 1. Sensor Unit 2. Solenoid Valve 3. Mounting Bracket (for cavity walls or ceiling tiles) 2 4. Remote Valve Plug & Gasket 5. Mounting Screws M3.5

More information

Designed to touch. Geberit actuator plates for WC flush controls

Designed to touch. Geberit actuator plates for WC flush controls Geberit South East Asia Pte Ltd 59 Jalan Pemimpin, #01-01 L&Y Building, Singapore 577218, Singapore T: +65 6250 4011 F: +65 6250 4211 E: sales.sg@geberit.com www.geberit.com.sg Geberit South East Asia

More information

Systems for Wall-Hung Toilets for Sigma 2x6 Installation

Systems for Wall-Hung Toilets for Sigma 2x6 Installation GEBERIT INSTALLATION SYSTEMS Geberit Installation Systems Systems for Wall-Hung Toilets for Sigma 2x6 Installation Geberit Duofix Carrier, Sigma 2x6 Installation Model No. Description List Price 111.335.00.5

More information

Urinal Flushing. Hydraulic Valve Infrared Control (IRC) Valve Direct Flush

Urinal Flushing. Hydraulic Valve Infrared Control (IRC) Valve Direct Flush Urinal Flushing Hydraulic Valve Infrared Control (IRC) Valve Direct Flush Hydraulic Valve Urinal flush control valve Reduces water consumption and washroom odours The Hydraulic Valve is an automatic urinal

More information

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners

More information

Duo water control system

Duo water control system Duo water control system Installation and maintenance guide DUOINSTRUCT Contents Important and safety information Pack contents / Tools required Duo trim plate dimensions Flow performance Typical wall

More information

Operating instructions Flow monitors SI / / 2010

Operating instructions Flow monitors SI / / 2010 Operating instructions Flow monitors SI5004 UK 704339 / 02 08 / 2010 Contents 1 Safety instructions 3 2 Functions and features 4 2.1 Application area 4 2.2 Operating principle flow monitoring 4 3 Installation

More information

Chapter 6. Plumbing Elements and Facilities

Chapter 6. Plumbing Elements and Facilities AMERICAN NATIONAL STANDARD Chapter 6. Plumbing Elements and Facilities Chapter 6. Plumbing Elements and Facilities 601 General 601.1 Scope. Plumbing elements and facilities required to be accessible by

More information

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories

More information

Systems for Floor-Mounted, Back Outlet Toilets, 2x6 Installation

Systems for Floor-Mounted, Back Outlet Toilets, 2x6 Installation Geberit Flushing System Systems for Floor-Mounted, Back Outlet Toilets, 2x6 Installation GEBERIT FLUSHING SYSTEM Concealed Tank, Sigma 2x6 Installation Model No. Description List Price 109.304.00.5 Sigma

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

LED.Commercial 12W LED DD

LED.Commercial 12W LED DD LED.Commercial 12W LED DD 12W GR8 (2-pin) & GR10q (4-pin) LED DD Lamp Product Overview Kosnic s range of LED DD lamps takes a fresh approach to functional lighting with a design philosophy offering plug-in

More information

Water, vibration and oil resistant LED work light, suitable for machine tools applications and high temperature water cleaning environments

Water, vibration and oil resistant LED work light, suitable for machine tools applications and high temperature water cleaning environments 67 69K Water, vibration and oil resistant LED work light, suitable for machine tools applications and high temperature water cleaning environments Common Specifications(QML/ QMHL) Excellent oil resistance

More information

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire

More information

Kitchen Tara Ultra. UNI SET Single-lever mixer Article number: Single-lever mixer Article number:

Kitchen Tara Ultra. UNI SET Single-lever mixer Article number: Single-lever mixer Article number: UNI SET Single-lever mixer Article number: 37 847 875 and spray flow single-lever mixer hole diameter 35mm hole diameter rinsing spray 32mm fabric braided hose 1500mm Recommended minimum flow pressure:

More information

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170 SWING ARM MAGNIFYING LAMP MODEL NO: SAM170 PART NO: 54605338 ASSEMBLY & OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0217 INTRODUCTION Thank you for purchasing your CLARKE swing arm magnifying lamp,

More information

Designed to touch. Geberit actuator plates for WC flush controls

Designed to touch. Geberit actuator plates for WC flush controls Designed to touch. Geberit actuator plates for WC flush controls 1 The choice is up to you. Actuator plates for your dream bathroom. Design your new bathroom exactly according to your tastes and your requirements.

More information

Mira Mode Shower and Bath Fittings

Mira Mode Shower and Bath Fittings Mira Mode Shower and Bath Fittings Installation Guide Please leave these instructions with the user If you experience any difficulty with the installation or operation of your new shower, then please refer

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features: Technical Data Round Pin And xport Socket Outlets Brief product description: The subtle design will blend with any décor - suitable for domestic or commercial installations. Universal socket will accept

More information

SY PVC / BS EN Control Flexible Cable

SY PVC / BS EN Control Flexible Cable SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Installation Instructions 1662SG SG.223

Installation Instructions 1662SG SG.223 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation

More information

San Remo. Uncluttered design. Ideal Standard S.A. Regions: Greece Mediterranean Middle East, Asia

San Remo. Uncluttered design. Ideal Standard S.A. Regions: Greece Mediterranean Middle East, Asia Ideal Standard S.A. Regions: Greece Mediterranean Middle East, Asia 265 Messogion Avenue 154 51 N.Psychiko Athens - Greece Tel.: +30 67 / 67877 Fax: +30 67892 Ideal Standard International Group of companies

More information

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features: Technical Data Round Pin And xport Socket Outlets Brief product description: The subtle design will blend with any décor - suitable for domestic or commercial installations. Universal socket will accept

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

BATHROOM EXTRACT FANS DECOR-100 Series

BATHROOM EXTRACT FANS DECOR-100 Series DECOR-1 Series Range of axial extractors with airflow rates of 1 m 3 /h, for connection to 1 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

Installation Instructions 1662SG SG.222

Installation Instructions 1662SG SG.222 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm & 2. gpm Installation Instructions 12SG.212 12SG.222 12SG.212 (1.gpm) 12SG.222 (2.gpm) Thank you for selecting American-Standard...the benchmark of fine quality for

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

COMFORT THROUGH ELECTRONICS

COMFORT THROUGH ELECTRONICS SANIT INEO electronic flush activation. radio controlled. cable controlled. infrared controlled COMFORT THROUGH ELECTRONICS WWW.SANIT.COM BARRIER-FREE CONSTRUCTION ACCORDING TO DIN 18040 WC control system,

More information

Installation Instructions 1662SG SG.224

Installation Instructions 1662SG SG.224 COMMERCIAL SHOWER SYSTEM KITS: 1. gpm &. gpm Installation Instructions 1SG.1 1SG. Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation

More information

ENGELS GROUP Shaping Inspiration NINETY YEARS. PRODUCT LIST lavanto 2017 / 2018

ENGELS GROUP Shaping Inspiration NINETY YEARS. PRODUCT LIST lavanto 2017 / 2018 ENGELS Shaping Inspiration GROUP 1927 2017 NINETY YEARS PRODUCT LIST lavanto 2017 / 2018 2 Product List lavanto 2017 / 2018 Contents Contents PRODUcT LIST lavanto Sinks 6-13 owls 16-30 Top-mount asins

More information

The Impact of the 18 th edition (BS 7671:2018)

The Impact of the 18 th edition (BS 7671:2018) The Impact of the 18 th edition (BS 7671:2018) In this article, Geoff Cronshaw looks at some of the proposed changes in the DPC (draft for public comment) for electrical installations, focusing on Section

More information

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions P 1 of 4 Single Colour Installation Instructions IMPORTANT PLEASE READ BEFORE INSTALLATION Before commencing installation ensure the relevant mains supply has been safely isolated. Installation should

More information

STAINLESS STEEL WASHROOM SOLUTIONS

STAINLESS STEEL WASHROOM SOLUTIONS STAINLESS STEEL WASHROOM SOLUTIONS i Find out more at www.aquazone-uk.com Oakwell Park Trading Estate Oakwell Way, Birstall, Leeds, England WF17 9LU Tel : +44 (0)1924 233977 Fax : +44 (0)1924 233966 info@aquazone-uk.com

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

STAINLESS STEEL WASHROOM SOLUTIONS

STAINLESS STEEL WASHROOM SOLUTIONS STAINLESS STEEL WASHROOM SOLUTIONS Oakwell Park Trading Estate Oakwell Way, Birstall, Leeds, England WF17 9LU Tel : +44 (0)1924 233977 Fax : +44 (0)1924 233966 info@aquazone-uk.com www.aquazone-uk.com

More information

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz III Nominal voltages up to 30 kv / 50 Hz EN/IEC 61243-1 (DIN VDE 0682 411) Also for use in wet weather for indoor and outdoor installations With self-testing device Visual indicator Wide nominal voltage

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

NEWS MARCH RRP excl. V.A.T.

NEWS MARCH RRP excl. V.A.T. NEWS MARCH 2018 RRP excl. V.A.T. INDEX PLAN blue Fittings (539)... 01.01-01.06 EDITION 400 Accessories (115)... 02.01-02.02 PLAN Accessories (149)... 03.01-03.03 COSMETIC MIRRORS Accessories (176)... 04.01-04.04

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems F L 1 5 0-3 B Metal Halide Light Generator for Fiber Optic Lighting Systems User Manual This user manual describes the following product: Item number 0161 0000 FL 150-3 B. White light. 99082019 Rev. 30.06.09

More information

Viega Flushing System Technology. List Price Book Volume

Viega Flushing System Technology. List Price Book Volume Viega Flushing System Technology List Price Book Volume 2 2017 CONTENTS 4Viega flush plates 14 WC in-wall flushing carrier systems 16 Urinal in-wall flushing carrier systems 20 Sink and bidet carriers

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

tapware bath set wall top assemblies washing machine stops basin set Also available with ceramic disc

tapware bath set wall top assemblies washing machine stops basin set Also available with ceramic disc product range tapware bath set 2205210 65 39 52 135 wall top assemblies 2205250 Ø52 washing machine stops 2205260 Also available with ceramic disc basin set 9502922 Fixed outlet 115 19 35.5 25 105 120

More information

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet Pump Station Ama-Porter CK Pump Station Type Series Booklet Legal information/copyright Type Series Booklet Ama-Porter CK Pump Station All rights reserved. The contents provided herein must neither be

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

LEAD ACID BATTERY CHARGER

LEAD ACID BATTERY CHARGER LEAD ACID BATTERY CHARGER MODEL NO: LA4 & LA6 OPERATION & MAINTENANCE INSTRUCTIONS LS1214 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger. Please read this manual thoroughly, before attempting

More information

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011) Author: IET Publications (edited by Mark Coles) Book details Author: IET Publications (edited by Mark Coles) Year: 2011 Format: Paperback,

More information

CB14 CB14 XW CB14 Full Flush

CB14 CB14 XW CB14 Full Flush CB14 CB14 XW CB14 Full Flush Asphalt Compactors Cat C1.1 Diesel Engine CB14 CB14 XW CB14 XW CB14 Full Flush Gross power (ISO 14396) at 2400 rpm 16.1 kw/22 hp 16.1 kw/22 hp 16.1 kw/22 hp 16.1 kw/22 hp Net

More information

10W LED Die Cast Small Rectangle Bulkhead Light

10W LED Die Cast Small Rectangle Bulkhead Light 10W LED Die Cast Small Rectangle Bulkhead Light Model: LEDBHRE10W Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference

More information

WC PANS, SQUAT PANS, URINALS & SHOWERS FRANKE WC PANS ARE DESIGNED TO REDUCE WATER CONSUMPTION BY UP TO

WC PANS, SQUAT PANS, URINALS & SHOWERS FRANKE WC PANS ARE DESIGNED TO REDUCE WATER CONSUMPTION BY UP TO WC Pans, squat pans, urinals & showers FRANKE WC PANS ARE DESIGNED TO REDUCE WATER CONSUMPTION BY UP TO 60% WC Pans consume up to 90 percent of water usage in commercial buildings. New technology has been

More information

G SERIES - E TOUCH MIXER / TAP

G SERIES - E TOUCH MIXER / TAP PLUMBERS Installation and maintenance INSTRUCTIONS G SERIES - E TOUCH MIXER / TAP electronically operated MIXER / TAP G Series E Touch Basin Tap G Series E Touch Basin Mixer 1 IS1301C (03/15) INDEX 3 IMPORTANT

More information

METLAM PARTITION HARDWARE. Metlam Partition Hardware. > Washroom Hardware & Accessories

METLAM PARTITION HARDWARE. Metlam Partition Hardware. > Washroom Hardware & Accessories METLAM PARTITION HARDWARE Metlam Partition Hardware > Washroom Hardware & Accessories Metlam Proud to be Australian Owned Metlam is proud to be Australian owned and managed. Formed in the mid 1990 s, it

More information

WC UNITS. WC units. 68 Products Ifö

WC UNITS. WC units. 68 Products Ifö WC units 8 s Ifö WC UNITS WC units We have been making WC units for the Nordic market for 7 years. nother aspect is environmental awareness. For example, we developed the ENVIRONMENTL BUTTON 4/2 litre

More information

28W WORK LAMP Model: CTL28 Part No:

28W WORK LAMP Model: CTL28 Part No: 28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609 INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read

More information

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011 Operating instructions Flow monitors SI6600 SI6700 SI6800 UK 704680/02 01/2011 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Functions and features 4 3.1 Application

More information

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical

More information

Bathroom Collection Vanity Units Vitreous China Basins Toilet Suites Mixer Taps

Bathroom Collection Vanity Units Vitreous China Basins Toilet Suites Mixer Taps Bathroom Collection s Vitreous China Basins Toilet Suites Mixer Taps National Customer Service Number 13 1926 Everything Water Vitreous China Basin Range The Virtue by Everhard range of vitreous china

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 750W SUBMERSIBLE PUMP WITH BUILT-IN FLOAT SWITCH MODEL NO: PSV5A PART NO: 7236046 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0917 iss 3 INTRODUCTION Thank you for purchasing this CLARKE

More information

X-JET (Counter current system)

X-JET (Counter current system) X-JET (Counter current system) GB Instruction Manual Translation of the original 27131 - A SOMMAIRE Contents 1 General... 3 1.1 Warranty instructions... 3 1.2 General... 3 1.3 Usage instructions... 3 2

More information

Sanitary Ware Expert, Your best choice!

Sanitary Ware Expert, Your best choice! (VI) Telephone function (optional) When the machine is turned on, the icon will flicker on the panel if there is an incoming call; meanwhile, the speaker will play the ring tone. Touch the button on the

More information

NEOZED D0 fuse-links gg 400/440VAC

NEOZED D0 fuse-links gg 400/440VAC NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

Operating instructions Spray nozzle SDU

Operating instructions Spray nozzle SDU Operating instructions Spray nozzle SDU INDEX Page 1. General... 2 2. Safety... 2 4 A. Nozzles type... 5 B. Nozzles inserts... 5 C. Revision... 5 D. Monitoring... 6 E. Heating... 6 F. Accessories... 6

More information

Medifab AU 1300 b NZ Page 1

Medifab AU 1300 b NZ Page 1 Medifab Ltd Australia: 26 Pardoe Street, Devonport, TAS 7310 New Zealand: 32 Detroit Drive, Rolleston 7675 Call 1300 543 343 (AU) Call 0800 543 343 (NZ) www.medifab.com solutions@medifab.com Medifab AU

More information

Data sheet chainflex CF886

Data sheet chainflex CF886 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.

More information

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER HIGH FREQUENCY AUTOMATIC BATTERY CHARGER MODEL NO: HFBC12 PART NO: 6267000 OPERATION & MAINTENANCE INSTRUCTIONS LS0814 INTRODUCTION Thank you for purchasing this CLARKE High Frequency Automatic Battery

More information

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1 Installation Instructions Mirror Solutions Bevel & Pivot Models 620095-620098 Mirror Solutions Bevel - Models # 620095 & 620096 Mirror Solutions Pivot - Models # 620097 & 620098 Figure 1 INSTALLATION INSTRUCTIONS

More information

Planning and dimensioning of the drinking water system

Planning and dimensioning of the drinking water system Planning and dimensioning of the drinking water system The planning and dimensioning of the drinking water system is based on DIN 1988 technical regulations for drinking water (TRWI) as well as for determining

More information

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1 TBi Industries MIG / MAG Welding torches TBi Expert 1 0. 1 CONTENTS. TBi Expert Gas cooled torches TBi 150 Classic Series 60% (10 min.) Mix : 150 A CO 2 : 180 A Ø 0.6-1.0 mm Water cooled torches TBi 240

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Is a good feeling to be sure and independent

Is a good feeling to be sure and independent The Lift Toilet Instruction of use 1. Description 2. Safety details 3. Operation 4. Cleaning 5. Maintenance and guarantee 6. Trouble shooting 7. Spare parts Is a good feeling to be sure and independent

More information

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810 5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

GENERAL REQUIREMENTS FOR ACCESS

GENERAL REQUIREMENTS FOR ACCESS GENERAL REQUIREMENTS FOR ACCESS AS1428 SERIES 2009 EDITION COPYRIGHT GRIMBOS BUILDING SURVEYORS ACCESSIBLE TOILET MINIMUM CLEARANCES Compartment Size 2100mm x 2700mm Pan Circulation Space 1900mm x 2300mm

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional

More information

Lighting series JLZ Lighting series JELZ

Lighting series JLZ Lighting series JELZ C A B I N L I G H T S Lighting series JFZ Lighting series JFZS Lighting series JLZ Lighting series JELZ 2011/09 CABIN LIGHTS Description of lighting: The JUNG lighting series JFZS, JFZ, JLZ and JELZ are

More information