Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

Size: px
Start display at page:

Download "Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics"

Transcription

1 Table of Contents Emergency Cable Pull Switches Operator Interface Overview LIfeline ope Tensioner System (LTS) Lifeline Lifeline Lifeline 4 Stainless Steel Enabling Switches GripSwitch Push Button Switches 22.5 mm mm Two-Hand Control Devices Touch Buttons 800Z Zero-Force Touch Buttons General 1-2-Opto-electronics Power Logic 4-Table of Contents Safety Switches 4-1

2 Cable Pull Switches Overview General 1-2-Opto-electronics Safety Switches Logic Power Cable Pull Switches Overview For machinery such as conveyors, it is often more convenient and effective to use a cable pull device along the hazard area (as shown in the figure below) as the emergency stop device. These devices use a steel wire rope connected to latching pull switches so that pulling on the rope in any direction at any point along its length will trip the switch to cut off the machine power. The cable pull switches must detect both a pull on the cable as well as when the cable goes slack. Slack detection ensures that the cable is not cut and is ready for use. ockwell Automation developed a unique Lifeline ope Tensioner System (LTS) which helps enable quicker installations. A dedicated stainless steel installation kit must be used with the stainless steel Lifeline 4 instead of the LTS. Selection Guide Lifeline 3 Lifeline 4 Material Painted Zinc Alloy Painted Aluminum Alloy Stainless Steel Lifeline 4 Stainless Steel 316 eset Yes Yes Yes E-Stop No Yes Yes Cable Span Typical Applications 30 m (98.42 ft) Mounting Specifications for Extended Length Models Lifeline 4 Cable Grips Steel Cable Tensioner Tensioner P. Bolts Tension Indicator 300mm (11.81in) 2-3m (6.5-9ft) m ( ft) 75 m (246 ft) 125 m (410 ft) extended model 75 m (246 ft) E-Stop Button eset Knob Notes: 1. The first and last P. bolt/eye bolt must be located as close as possible to the switch eyelet while maintaining adequate clearance (125 mm/5 in) from the cable grips to allow free movement. This provides for a straight and efficient pulling action on the switches. 2. Additional P. bolts/eye bolts, spaced 2-3 m (6-9 ft) apart, help keep the perpendicular pull force, F, and distance, d, within IEC specifications of 200 N (45 lbs) and 400 mm (15.75 in). 3. We recommend using a switch at both cable ends, especially in applications with long cable runs or cable runs going around bends. This helps ensure that the safety function is fulfilled upon actuation of the cable in any direction. 4. ISO requires that the full length of cable to be within view when the reset is turned to the run position or the machine must be inspected over the whole length of the cable, both before and after resetting. 5. On shorter cable runs (max 10 m), a Lifeline tensioner spring may be used at one end of the span. The installation must be such that the above requirements can be met. When a spring is used, the last P. Bolt/eye bolt must be located as close as possible to the spring while maintaining adequate clearance (125 mm/5 in) from the cable grips to allow free movement. This is intended to help to ensure that a pull near the end of the cable will be between P. Bolts/eye bolts. This should result in operation of the switch contacts instead of only the spring moving. 6. Careful attention is required for the design of the installation to ensure that the cable is not likely to become trapped or snagged. This is especially important when using a tensioner spring because a cable snag between the location of the pull and the switch could prevent the actuation of the safety function. 7. It is essential that when the installation is complete, a thorough functional test is made. This should include checking all types and directions of pull over the length of the cable as well as checking for slack-cable tripping. 4-2

3 Cable Pull Switches Overview Mounting Specifications for Standard ope Length Models Lifeline 4 E-Stop Button Lifeline 3 Tension Indicator Cable Grips Polypropylene-covered steel cable Tensioner P. Bolts eset Knob L1 L2 Lifeline mm (11.81 in) 75 m (246 ft) Lifeline mm (5 in) 30 m (98 ft) General Tension Indicator L1 2-3m (6-9ft) F d eset Knob 1- L2 Stainless Steel Lifeline 4 ope Grips Polypropylene Covered Steel ope Tensioner Eye Bolts Thimble E-Stop Button Tension Indicator 300 (11.81) 2-3 m (6.5-9 ft) 75 m (246 ft) eset Knob 2-Opto-electronics Mounting Specifications with Spring Tensioner Lifeline 4 Lifeline 3 Tension Indicator Stainless Steel Lifeline 4 Tension Indicator L1 ope Grips (SS) 2-3m (6-9ft) F Polypropylene Covered Steel ope d Tensioner L2 Tensioner (SS) Tensioner Spring Eye Bolts (SS) Wall L1 L2 Lifeline mm (11.81 in) 75 m (246 ft) Lifeline mm (5 in) 30 m (98 ft) Thimble (SS) Lifeline Tensioner Spring (SS) Safety Switches Tension Wall m (6.5-9 ft) (11.81) Indicator 75 m (246ft) The choice between using two switches or one switch and a spring is a matter of a risk assessment taking into consideration the probability of a trapped rope along the span. See also notes 3 and 6 on the previous page. Logic Power 4-3

4 Cable Pull Switches Lifeline ope Tensioner System (LTS) General 1-2-Opto-electronics Safety Switches The LTS is a unique cable (rope) tensioning system which enables quicker installation of cable actuated systems. Other methods are traditionally time consuming and sometimes awkward to fit. Features of the system include: 1. Cable adjustment up to 300 mm (11.8 in) (150 mm (5.9 in) either side of tensioner) 2. Quick thread and grip of cable with cable grip 3. Cable tidy incorporated into the cable grips 4. Simple tensioning via the tensioner with allen key. Due to the appeal of quick installation and universal use, the LTS can also be used for applications other than cable actuated emergency stop systems. Features Unique cable grip system Can be installed and commissioned in approximately 3 minutes Ease of installation, no specialty tools required Up to 300 mm (11.8 in) of cable adjustment Cable tidy incorporated into cable grips Specifications Material Color Weight [g (lb)] Operating Temperature [C (F)] Cable O.D. Cable Adjustment ange, Max. Tensioner Holding Force, Max. Gripper Holding Force, Max. Enclosure Type ating Tensioner Adjustment Tool Four Steps to Install Thread rope grip 1 Thread eyebolts & tensioner Tensioner: Glass-filled nylon Cable gripper: Acetal, zinc alloy, stainless steel Cable gripper gears: Stainless steel Cable: Cable to BS 302:1987, wire Ø4.0 Steel Core with polypropylene sheath P. Bolt: Stainless steel Tensioner: Yellow Cable gripper: Yellow/natural Cable: ed P. Bolt: Natural Tensioner: 140 (0.31) Cable gripper: 80 (0.17) ( ) 4 mm (0.15 in.) 300 mm (11.8 in.) 500 N (112.5 lbf) 280 N (63.0 lbf) IP30 5 mm A/F Allen key Thread rope grip 2 Tension system Logic Power 4-4

5 Cable Pull Switches Lifeline ope Tensioner System (LTS) Product Selection No. of P-Bolts Installation Kit 5 m (16.4 ft) 3 440E-A13079 Installation Kit 10 m (32.8 ft) 6 440E-A13080 Installation Kit 15 m (49.2 ft) 8 440E-A13081 Installation Kit 20 m (65.6 ft) E-A13082 Installation Kit 30 m (98.4 ft) E-A13083 Installation Kit 50 m (164 ft) E-A13084 Installation Kit 75 m (246 ft) E-A13085 A stainless steel tensioner kit is available for use with the Lifeline 4 Stainless Steel, see page General Accessories 1- Lifeline tensioner and Allen key only 440E-A17105 Lifeline gripper two pack Lifeline gripper 20 pack Lifeline tensioner, two grippers and Allen wrench 440E-A E-A E-A Opto-electronics Two Lifeline tensioners, two grippers and Allen wrench 440E-A m (49.2 ft) 440E-A m (98.4 ft) 440E-A17027 Polypropylene covered steel cable 100 m (328 ft) 440E-A m (410 ft) 440E-A m (984 ft) 440E-A m (1640 ft) 440E-A17032 UV resistant polypropylene covered 100 m (328 ft) 440E-A14739 ed Cable steel cable 300 m (984 ft) 440E-A14740 Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. 12 (0.47) Dia. 43 (1.69) 70 (2.75) Dia. 90 (3.54) 45 (1.77) Safety Switches 40 (1.57) Cable Grip 67 (2.63) 25 (0.98) Tensioner Logic Cable Cable Grip P. Bolts Tensioner Note: 2D, 3D and electrical drawings are available on Power 4-5

6 Cable Pull Switches Lifeline 3 General 1-2-Opto-electronics Safety Switches Logic Power The Lifeline 3 is a cable (rope) operated emergency stop device designed to meet the stringent requirements of ISO (Safety of Machinery Emergency Stop Equipment). The Lifeline 3 system can be installed along or around awkward machinery such as conveyors and provides a constant-access emergency-stop facility. 1. The positive-mode mechanism helps ensure that the contacts are immediately latched open on actuation and can only be reset by the intentional action of turning the blue reset knob. The design also protects against nuisance tripping and the effects of thermal expansion. 2. The cable-status indicator makes the system easy to set up and maintain for spans up to 30 m (98 ft). 3. Four sets of contacts are provided: 2 N.C. + 2 N.O., or 3 N.C. + 1 N.O. contacts. 4. Sealed to IP 67 with rugged construction using die-cast alloy and stainless steel to withstand harsh conditions. Features Switches up to 30 m (98 ft) span Universal mounting and operation Switch lockout on cable pulled and cable slack Cable-status indicator on switch lid Industry standard fixing centers to DIN/EN Quick disconnect styles available Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit Certifications Outputs Safety Contacts Auxiliary Contacts ISO 13850, EN ISO 12100, IEC , IEC Cat. 1 device per EN May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO :2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics CE Marked for all applicable directives, culus, TÜV, and CCC 2 N.C. directopening action 2 N.O. directopening action 3 N.C. directopening action 1 N.O. directopening action Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Voltage, Min. 5 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Cable Span Between Switches, Max. 30 m (98 ft) Tensioning Force to un Position 103 N (23.17 lbf) typical Tensioning Force to Lockout 188 N (42.3 lbf) typical Operating Force, Min. <125 N (28.1 lb) at 300 mm deflection Actuation Frequency, Max. 1 cycle/s Operating 100 ma load 1 x 106 Environmental Enclosure Type ating IP67 Operating Temperature [C (F)] ( ) Physical Characteristics Housing Material Heavy-duty painted zinc-based diecast alloy Indicator Material Glass-filled nylon Eye Nut Material Stainless steel Weight [g (lb)] 610 (1.34) Color Yellow body, blue reset button Usable for ISO :2006 and IEC Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. Note: It is recommended that the LTS (Lifeline ope Tensioning System) should be used with the Lifeline 3 cable rope switch. 4-6

7 Cable Pull Switches Lifeline 3 Product Selection Contacts Conduits Connectors Connect to ArmorBlock Guard I/O Safety Auxiliary M20 1/2 inch NPT 12-Pin M23 8-Pin Micro (M12) 5-Pin Micro (M12) 2 N.C. 2 N.O. 440E-D E-D E-D E-D21BNYH 440E-D2NNNYS 3 N.C. 1 N.O. 440E-D E-D E-D13124 For connector ratings, see page 3-9. With an 8-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagram on page 4-9 for wiring details. For connection to ArmorBlock Guard I/O. With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagram on page 4-9 for wiring details. ecommended Logic Interfaces Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Single-Function Safety elays for 2 N.C. Contact Switch MS127P 3 N.O. 1 N.C. emovable (Screw) Monitored Manual 24V AC/DC N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC N23132 MS126T 2 N.O. None Fixed Auto./Manual 24V AC/DC N23117 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or Monitored Manual 24V DC N23198 Modular Safety elays MS210P Base 1 N.C. and 2 PNP Auto./Manual or 24V DC from the 2 N.O. emovable 2 N.C. only Solid State Monitored Manual base unit H23176 MS220P Input Module emovable 24V DC H23178 MS310P Base MS300 Series Auto./Manual 3 PNP Solid State emovable Output Modules Monitored Manual 24V DC W23219 MS320P Input Module Note: For additional Safety elays connectivity, see the Safety elays section (page 5-8) of this catalog. For additional Safety I/O and Safety PLC connectivity, see the Programmable Safety System section (page 5-115) of this catalog. For application and wiring diagrams, see the Safety Applications section (page 10-1) of this catalog. Connection Systems 2 PNP Solid State emovable 5-Pin Micro (M12) 8-Pin Micro (M12) 12-Pin M23 Cordset 889D-F8AB- 889M-FX9AE- Patchcord 889D-F5ACDM- 889D-F8ABDM- 889M-F12AHMU- eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 0M3 (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths. To connect to ArmorBlock Guard I/O. 24V DC from the base unit W23218 General 1-2-Opto-electronics Safety Switches Power Logic 4-7

8 Cable Pull Switches Lifeline 3 General 1-2-Opto-electronics Safety Switches Accessories Lifeline P. bolt M8 x 1.25 thread size, 58 mm (2.28 in.) threaded length, 12 mm (0.47 in.) dia. eye, 95 mm (3.74 in.) overall length Lifeline tensioner spring 19 mm (0.75 in.) diameter, 210 mm (8.27 in.) overall length, 50 N force Lifeline inside corner pulley Internal diameter 16 mm (0.64 in.) zincplated mild steel Lifeline outside corner pulley Outside diameter 38 mm (1.5 in.) zincplated mild steel Blanking plug, M20 conduit Cable grip, M20 conduit, accommodates cable diameter mm ( in.) Adaptor, conduit, M20 to 1/2 inch NPT, plastic Screwdriver including security bit Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. 56 (2.2) 43 (1.69) 10.5 (0.41) 40 ( (2.36) 204 (8.03) 4 x M5 mounting holes 440E-A E-A A-A A-A A-A A-A A-A A-A09018 Logic Power 30 (1.18) Note: 2D, 3D and electrical drawings are available on 4-8

9 Typical Wiring Diagrams 2 N.C. & 2 N.O. 3 N.C. & 1 N.O. Operator Interface Cable Pull Switches Lifeline 3 General Contact Configuration Safety A Safety B Aux A Aux B Safety A Safety B Safety C Aux A Contact Action Open Closed 5-Pin Micro (M12) for ArmorBlock Guard I/O 8-Pin Micro (M12) 0 mm Safety A Safety B Aux A Aux B Cable Slack Lockout 5-Safety B 3-NA 3-Ground 8-Safety A 4-Safety B 5-Safety A Cable Tension ange 2-Safety A Cable Pulled Lockout 1-Safety A 4-Safety B 2-N/A 1-Aux A 7-Aux A 6-Safety B Safety A Safety B Safety C Aux B 0 mm Cable Slack Lockout Cable Tension ange 12-Pin M Safety A Safety A Pins 2, 5, 11 not connected 8-Pin Cordset 889D-F8AB Pin Cordset 889M-FX9AE- 4-6 Safety B Safety B 7-8 Aux A Safety C 9-10 Aux B Aux A 12 Ground Ground Grey ed Yellow Pink White Blue Green Brown Brown Blue White Green Yellow Grey Pink ed Green Yellow Safety A Safety B Aux A Aux B Ground eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 0F5 (0.5 ft) or 1F (1 ft) for standard cable lengths. Safety A Safety B Aux A Ground Not Used Safety A Safety B Safety C Aux A Ground Cable Pulled Lockout 1-2-Opto-electronics Safety Switches Logic Power 4-9

10 Cable Pull Switches Lifeline 4 General 1-2-Opto-electronics Safety Switches Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The Lifeline 4 is the only device of its kind to incorporate the following features in one unit making it the most versatile cable switch on the market. 1. The positive mode mechanism helps ensure that the contacts are immediately latched open on actuation and can only be reset by the intentional action of turning the blue reset knob. The design also protects against nuisance tripping and the effects of thermal expansion. 2. A mushroom head emergency stop button is included on the unit to provide E-Stop access even at the extreme ends of the span. 3. The cable status indicator makes the system easy to set up and maintain for spans up to 125 meters. 4. Four sets of contacts are provided: 2 N.C. + 2 N.O. or 3 N.O. + 1 N.O. contacts 5. Sealed to IP66 with rugged construction using die-cast alloy and stainless steel to withstand harsh conditions. Features Switches up to 125 meter span Universal mounting and operation Lid mounted emergency stop button, designed to conform to ISO 850 Switch lockout on cable pulled and cable slack Cable status indicator on switch lid Lid mounted E-Stop button A mushroom head emergency stop button is included on the unit to provide total E-Stop access even at the extreme ends of the span. Cable status indicator on lid The cable status indicator makes the system easy to setup and maintain for spans up to 125 meters. Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit Certifications Outputs Safety Contacts Auxiliary Contacts ISO 13850, EN ISO 12100, IEC , IEC Cat. 1 device per EN May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO :2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics CE Marked for all applicable directives, culus, TÜV, and CCC 2 N.C. directopening action 2 N.O. directopening action 3 N.C. directopening action 1 N.O. directopening action Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Voltage, Min. 5 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Cable Span Between Switches, Max. Tensioning Force to un Position Tensioning Force to Lockout 75 m (246 ft) standard model and m ( ft) extended length model 103 N (23.16 lbf) typical 188 N (42.3 lbf) typical Operating Force, Min. <125 N (28.1 lbf) at 300 mm deflection Actuation Frequency, Max. 1 cycle/s Operating 100 ma load 1 x 106 Environmental Enclosure Type ating IP66 Operating Temperature [C (F)] ( ) Physical Characteristics Housing Material Heavy-duty painted zinc-based diecast alloy (LM24) Indicator Material Glass-filled nylon Eye Nut Material Stainless steel Weight [g (lb)] 630 (1.38) Color Yellow body, blue reset button Usable for ISO :2006 and IEC Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. Note: It is recommended that the LTS (Lifeline ope Tensioning System) should be used with the Lifeline 4 cable rope switch. 4-10

11 Cable Pull Switches Lifeline 4 Product Selection Cable Span Safety Contacts Auxiliary Contacts 75 m (246 ft) m ( ft) Conduits Connectors M20 1/2 inch NPT 12-Pin M23 8-Pin Micro Connect to ArmorBlock Guard I/O 5-Pin Micro (M12) 2 N.C. 2 N.O. 440E-L E-L E-L E-L21BNYH 440E-L2NNNYS 3 N.C. 1 N.O. 440E-L E-L E-L N.C. 2 N.O. 440E-L E-L E-L E-L21BTYH 3 N.C. 1 N.O. 440E-L E-L E-L13164 For connector ratings, see page 3-9. For connection to ArmorBlock Guard I/O. With a 5-pin micro (M12) connector, not all contacts are connected. See page 4-15 for wiring details. With an 8-pin micro (M12) connector, not all contacts are connected. See page 4-15 for wiring details. ecommended Logic Interfaces Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Single-Function Safety elays for 2 N.C. Contact Switch MS127P 3 N.O. 1 N.C. emovable (Screw) Monitored Manual 24V AC/DC N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC N23132 MS126T 2 N.O. None Fixed Auto./Manual 24V AC/DC N23117 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or Monitored Manual 24V DC N23198 Modular Safety elays MS210P Base 1 N.C. and 2 PNP Auto./Manual or 24V DC from the 2 N.O. emovable 2 N.C. only Solid State Monitored Manual base unit H23176 MS220P Input Module emovable 24V DC H23178 MS310P Base MS300 Series Auto./Manual 3 PNP Solid State emovable Output Modules Monitored Manual 24V DC W23219 MS320P Input Module 2 PNP Solid State emovable Note: For additional Safety elays connectivity, see page 5-4. For additional Safety I/O and Safety PLC connectivity, see page For application and wiring diagrams, see page Connection Systems 5-Pin Micro (M12) 8-Pin Micro (M12) 12-Pin M23 Cordset 889D-F8AB- 889M-FX9AE- Patchcord 889D-F5ACDM- 889D-F8ABDM- 889M-F12AHMU- eplace symbol with 0M3 (0.3 m), 1 ( 1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard lengths. eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 0M3 (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard length. 24V DC from the base unit W23218 General 1-2-Opto-electronics Safety Switches Power Logic 4-11

12 Cable Pull Switches Lifeline 4 Accessories General 1-2-Opto-electronics Safety Switches Lifeline P. bolt Lifeline tensioner spring eplacement cover for Lifeline 4 cable/push button eplacement cover for Lifeline 4 cable/push button, no E-Stop Lifeline inside corner pulley Lifeline outside corner pulley Mounting bracket for Lifeline 4 cable/push button Blanking plug, M20 conduit Cable grip, M20 conduit, accommodates cable diameter mm ( in.) Adaptor, conduit, M20 to 1/2 inch NPT, plastic Screwdriver including security bit 440E-A E-A E-A E-A A-A A-A E-A A-A A-A A-A A-A09018 Logic Power 4-12

13 Cable Pull Switches Lifeline 4 Accessories (continued) Indicator, M20 Conduit Pilot Light Amber Lens T-3 1/4 Insert Use T-3 1/4 Bulb (Sold Separately) Indicator, 1/2in NPT Conduit Pilot Light Amber Lens T-3 1/4 Insert Use T-3 1/4 Bulb (Sold Separately) Indicator, M20 Conduit Pilot Light Amber Lens Bayonet Style Insert Use LED Bulb (Sold Separately) Indicator, 1/2in NPT Conduit Pilot Light Amber Lens Bayonet Style Insert Use LED Bulb (Sold Separately) Indicator, M20 Conduit Pilot Light ed Lens T-3 1/4 Insert Use T- 3 1/4 Bulb (Sold Separately) Indicator, 1/2in NPT Conduit Pilot Light ed Lens T-3 1/4 Insert Use T-3 1/4 Bulb (Sold Separately) Indicator, M20 Conduit Pilot Light ed Lens Bayonet Style Insert Use LED Bulb (Sold Separately) Indicator, 1/2in NPT Conduit Pilot Light ed Lens Bayonet Style Insert Use LED Bulb (Sold Separately) Bulb, 24V for Conduit Pilot Light 2.8W T-3 1/4 Bulb, Miniature Screw Base Bulb, 110V for Conduit Pilot Light 2.6W T-3 1/4 Bulb, Miniature Screw Base Bulb, 240V for Conduit Pilot Light 0.75W T-3 1/4 Bulb, Miniature Screw Base ed LED Bulb, 24V AC/DC for Conduit Pilot Light Bayonet Style Insert Amber LED Bulb, 24V AC/DC for Conduit Pilot Light Bayonet Style Insert ed LED Bulb, 120V AC for Conduit Pilot Light Bayonet Style Insert Amber LED Bulb, 120V AC for Conduit Pilot Light Bayonet Style Insert 440A-A A-A A-A A-A A-A A-A A-A A-A A-A A-A A-A T-N T-N319A 800T-N T-N320A Safety Switches 2-Opto-electronics 1- General Power Logic 4-13

14 Cable Pull Switches Lifeline 4 General 1-2-Opto-electronics Safety Switches Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. Standard Model Extended Length Models ( m cable span) 51 (2.0) 85 (3.35) 81 (3.19)min (3.72)max 115 (4.53) 51 (2.01) 101 (3.98) 48 (1.89) 62 (2.44) 85 (3.35) 51 (2.0) Emergency Stop Button eset Button 4 Mounting Holes Clearance for M5 Screws 101 (3.98) 85 (3.35) Note: 2D, 3D and electrical drawings are available on (3.98) min. to (4.51) max. 115 (4.53) 37 (1.46) 10.5 (0.41) 48 (1.89) 62 (2.44) 7.0 (0.28) 25.5 (1.0) Logic Power 4-14

15 Typical Wiring Diagrams 2 N.C. & 2 N.O. 3 N.C. & 1 N.O. Operator Interface Cable Pull Switches Lifeline 4 General Contact Configuration Contact Action Open 8-Pin Micro (M12) Closed mm Safety A Safety B Aux A Aux B Cable Slack Lockout 3-Ground 8-Safety A 4-Safety B 5-Safety A Cable Tension ange Safety A Safety B Aux B Aux A Cable Pulled Lockout 2-N/A 1-Aux A 7-Aux A 6-Safety B Safety A Safety B Safety C Aux B Cable Slack Lockout Cable Tension ange Safety A Safety B Safety C Aux B 0 mm Pin M Safety A Safety A Pins 2, 5, 11 not connected 5-Pin Micro for ArmorBlock Guard I/O 8-Pin Cordset 889D-F8AB- 12-Pin Cordset 889M-FX9AE Safety B Safety B 7-8 Aux A Safety C 9-10 Aux B Aux A 12 Ground Ground 5-Safety B 2-Safety A 1-Safety A 3-NA 4-Safety B Grey ed Safety A Yellow Pink Safety B White Blue Aux A Green Ground Brown Not Used Brown Blue Safety A Safety A White Green Safety B Safety B Yellow Grey Aux A Safety C Pink ed Aux B Aux A Green Yellow Ground Ground eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 0F5 (0.5 ft) or 1F (1 ft) for standard cable lengths. Cable Pulled Lockout 1-2-Opto-electronics Safety Switches Logic Power 4-15

16 Cable Pull Switches Lifeline 4 Stainless Steel General 1-2-Opto-electronics Safety Switches Logic Power The stainless steel Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. This switch is made from stainless steel 316 and is suitable for external use, applications where there are hygiene requirements and other situations where a level of corrosion resistance is required. The Lifeline 4 is the only device of its kind to incorporate the following features in one unit making it the most versatile cable switch on the market. 1. The positive mode mechanism helps ensure that the contacts are immediately latched open on actuation and can only be reset by the intentional action of turning the blue reset knob. The design also protects against nuisance tripping and the effects of thermal expansion. 2. A mushroom head emergency stop button is included on the unit to provide E-Stop access even at the extreme ends of the span. 3. The cable status indicator makes the system easy to set up and maintain for spans up to 75 meters. 4. Four sets of contacts are provided: 2 N.C. + 2 N.O. 5. Sealed to IP66 and IP69K with rugged construction using stainless steel 316 to withstand harsh conditions. Features Switches up to 75 m (246 ft) span Universal mounting and operation Lid mounted emergency stop button, designed to conform to ISO 850 Switch lockout on cable pulled and cable slack Cable status indicator on switch lid Made from stainless steel 316 Lid mounted E-Stop button A mushroom head emergency stop button is included on the unit to provide total E-Stop access even at the extreme ends of the span. Cable status indicator on lid The cable status indicator makes the system easy to setup and maintain for spans up to 75 m (246 ft). Specifications Safety atings Standards Safety Classification Functional Safety Data Note: For up-to-date information, visit EN , ISO 13850, EN ISO 12100, IEC Cat. 1 device per EN May be suitable for use in Cat 3 or Cat 4 systems depending on the architecture and application characteristics B10d: > 2 x 106 operations at min. load PFH D : < 3 x10-7 MTTFd: > 385 years May be suitable for use in performance levels Ple or Pld systems (according to ISO :2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics Certifications CE Marked for all applicable directives, culus Certified and TÜV Outputs Safety Contacts 2 N.C. direct opening action Auxiliary Contacts 2 N.O. Thermal CurrentI lth 10 A ated Insulation Voltage (Ui) 500V Switching Voltage, Min. 5 5V DC Utilization Category A600/AC-15 (Ue) 600V 500V 240V 120V (le) 1.2 A 1.4 A 3 A 6 A DC-13 (Ue) 24V (le) 2 A Operating Characteristics Cable Span Between Switches, Max. 75 m (246 ft) Tensioning Force to un Position 103 N (23.17 lbf) typical Tensioning Force to Lockout 188 N (42.3 lbf) typical Operating Force, Min. <125 N (28.1 lbf) at 300 mm deflection Actuation Frequency, Max. 1 cycle/s Operating 100 ma load 1 x 106 Environmental Enclosure Type ating IP66, IP67, IP69K Operating Temperature [C (F)] ( ) Physical Characteristics Housing Material Stainless steel 316 Indicator Material Acetal Eye Nut Material Stainless steel Weight [g (lb)] 1442 (3.17) Color Unpainted metal Usable for ISO :2006 and IEC Data is based on the B10d value given and: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing operations per year - Mission time/proof test interval of 38 years The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. Note: It is recommended that the stainless steel installation kit should be used with the stainless steel Lifeline 4 as it is made of suitable materials for harsh conditions. 4-16

17 Cable Pull Switches Lifeline 4 Stainless Steel Product Selection Conduits Connectors Cable Span Safety Contacts Auxiliary Contacts M20 1/2 inch NPT 12-Pin M23 Up to 75 m (246 ft) 2 N.C. 2 N.O. 440E-L22BNSM 440E-L22BNST 440E-L22BNSL For connector ratings, see 3-9. General ecommended Logic Interfaces Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Single-Function Safety elays for 2 N.C. Contact Switch MS127P 3 N.O. 1 N.C. emovable (Screw) Monitored Manual 24V AC/DC N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC N23132 MS126T 2 N.O. None Fixed Auto./Manual 24V AC/DC N23117 MS30T 2 N.O. Solid State 1 N.O. Solid State emovable Auto./Manual or Monitored Manual 24V DC N23198 Modular Safety elays MS210P Base 1 N.C. and 2 PNP Auto./Manual or 24V DC from the 2 N.O. emovable 2 N.C. only Solid State Monitored Manual base unit H23176 MS220P Input Module emovable 24V DC H23178 MS310P Base MS300 Series Auto./Manual 3 PNP Solid State emovable Output Modules Monitored Manual 24V DC W23219 MS320P Input Module 2 PNP Solid State emovable Note: For additional Safety elays connectivity, see page 5-4. For additional Safety I/O and Safety PLC connectivity, see page For application and wiring diagrams, see page V DC from the base unit W Opto-electronics Connection Systems 12-Pin M23 Cordset 889M-FX9AE- Patchcord 889M-F12AHMU- eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 0M3 (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard length. Safety Switches Power Logic 4-17

18 Cable Pull Switches Lifeline 4 Stainless Steel General 1-2-Opto-electronics Safety Switches Accessories Eye Bolts Stainless steel installation kit 5 m (16.4 ft) polypropylene 4 440E-A13194 Stainless steel installation kit 10 m (32.8 ft) polypropylene 4 440E-A13195 Stainless steel installation kit 15 m (49.2 ft) polypropylene 7 440E-A13196 Stainless steel installation kit 20 m (65.6 ft) polypropylene 8 440E-A13197 Stainless steel installation kit 30 m (98.4 ft) polypropylene E-A13198 Stainless steel installation kit 50 m (164 ft) polypropylene E-A13199 Polypropylene Covered Steel Cable Stainless steel installation kit 75 m (246 ft) polypropylene E-A13200 Stainless steel installation kit 5 m (16.4 ft) UV resistant 4 440E-A13220 Stainless steel installation kit 10 m (32.8 ft) UV resistant 4 440E-A13221 Stainless steel installation kit 15 m (49.2 ft) UV resistant 7 440E-A13222 Stainless steel installation kit 20 m (65.6 ft) UV resistant 8 440E-A13223 Stainless steel installation kit 30 m (98.4 ft) UV resistant E-A13224 UV esistant Polypropylene-Covered Steel Cable Stainless steel installation kit 50 m (164 ft) UV resistant E-A13225 Stainless steel installation kit 75 m (246 ft) UV resistant E-A13226 Stainless steel turn buckle kit (no cable) Stainless steel 304 eyebolt complete M8 x 1.25 thread size, 58 mm (2.28 in) threaded length, 12 mm (0.47 in) dia. eye 95 mm (3.74 in) overall length Stainless steel 316 tensioner spring, 19 mm (0.75 in) dia. 210 mm (8.27 in) overall length eplacement Cover eplacement cover no E-Stop Stainless steel 316 inside corner pulley Stainless steel outside corner pulley 440E-A E-A E-A E-A E-A E-A E-A13206 Note: Installation Kits include the following parts: one rope, one turnbuckle tensioner, four thimbles, eight rope grips and eyebolts, nuts and washers depending on the length of the rope. Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. Standard Model Logic Power 81 (3.19)min (3.72)max 115 (4.53) 48 (1.89) 62 (2.44) 85 (3.35) 51 (2.0) 101 (3.98) Note: 2D, 3D and electrical drawings are available on

19 Cable Pull Switches Lifeline 4 Stainless Steel Typical Wiring Diagrams 2 N.C. & 2 N.O. Power Logic General Contact Configuration Contact Action Open Closed Safety A Safety B Aux A Aux B Cable Slack Lockout Cable Tension ange Safety A Safety B Aux B Aux A 0 mm Pin M Safety A Pins 2, 5, 11 not connected 12-Pin Cordset 889M-FX9AE Safety B 7-8 Aux A 9-10 Aux B 12 Ground Brown Blue White Green Yellow Grey Pink ed Green Yellow eplace symbol with 0F5 (0.5 ft) or 1F (1 ft) for standard cable lengths. Safety A 1-2-Opto-electronics Safety Switches Safety B Aux A Aux B Ground Cable Pulled Lockout 4-19

20 Enabling Switches Overview General 1-2-Opto-electronics Safety Switches Overview An enabling device is a manually operated control device used in conjunction with a start control. The safety function of the enabling switch has two parts: 1) when continuously actuated, the enabling device allows machine operation, and 2) when not actuated, the enabling device initiates a stop command to prevent machine operation. Historically, many enabling devices used a two-position switch. In the event of an unexpected incident, the two-position switch is designed to open when the muscles relax. The three-position switch provides enhanced performance as it is designed to open when the muscles either relax or contract. The trend in machine safeguarding is towards the use of three-position switches. Various types of devices use the three-position switch as enabling devices. These are typically push buttons, grip switches and foot switches. The Allen-Bradley Guardmaster 440J is a hand-operated grip style enabling device. Underneath the rubber boot, called the trigger switch, the 440J enabling device has two three-position switches. The contacts are closed when the actuator is in the mid-position (partly depressed). The contacts are open when the actuator is in the rest (released) position and in the fully pressed position. When transitioning from fully pressed to released, the contacts remain open. The 440J meets the requirements of IEC :2006, which was written to describe the performance and design requirements of three-position enabling devices. elease Open "1" Ch1 Ch2 Mid-position Closed "2" Ch1 Ch2 Fully Pressed Open "3" Ch1 Ch2 Enabling devices are typically used when access to the hazardous portion of the machine is needed while the machine is running. Visual observations, minor adjustments, troubleshooting, calibration, tool changes, and lubrication are examples of tasks that may utilize an enabling device. Before accessing the machine, the operator must usually place the machine in a reduced performance role. A risk assessment must be performed to determine the level of reduced performance. The concept is that in the event of an unexpected event, the operator will either release or squeeze the actuator of the enabling device and disable the machine, prior to getting injured. The 440J enabling switches come in three models: 1) standard switch with no additional buttons, 2) switch with an additional single normally open contact, and 3) switch with an additional dual channel e-stop button. The model with the normally open contact is typically used as a jog or reset function. The safety system design must only allow the use of the jog or reset function when the trigger switch is in the midposition. The e-stop button has two normally closed contacts with direct opening action. The e-stop button latches when the contacts open per IEC and ISO When this model is selected with the quick disconnect option, the user must store the enabling switch in an out-of-sight location if it is disconnected. Mounting Considerations All three 440J enabling switches come with a base plate. All three models are offered with either a cable strain-relief or an M12 micro quick-disconnect connector. Base plate pre-mounted at the factory Cable Strain elief M12 Micro Quick Disconnect In some applications, the operation of the switch contacts is all that is needed. In this case, the holding bracket 440J-A00N is used. Logic Power Closed Open Position Closed Open Position Press 1 2 Press 1 2 Press 3 elease 1 elease 1 440J-A00N Additional accessory brackets can be added to achieve various arrangements. 440J-A01N right angle bracket is designed to accommodate 440K-A11238 (standard actuator) which is used with the standard Trojan 6 or Trojan T15 and 440G- A27011 (GD2 actuator) which is used with the GD2 interlocks. 4-20

21 Enabling Switches Overview 440J-A01N Bracket Shown with GD2 Actuator General With two additional screws, the right angle bracket can be mounted to the 440J enabling switch for horizontal mounting. An actuator can also be mounted for vertical use without the 440J-A01N bracket. Shown with 440G-A27011 GD2 Actuator Shown with 440K-A11095 Standard Actuator 1- Horizontal Mounting Vertical Mounting The mounting plate ( 440J-A02N) has multiple pre-drilled and tapped holes to facilitate mounting of a single 440K-MT (MT- GD2) or 440K-T (Trojan) interlock. Four additional through-holes at the corners allow mounting of the plate to a flat surface. MT-GD2 Interlock Horizontal Mount with MT-GD2 Vertical Mount with Trojan In some applications, additional contacts are needed when the enabling switch is used. Two additional accessories are used to allow the enabling switch to interact with two interlocks. 440J-A03N accessory mounts to the enabling switch base plate. This accessory has two sets of holes to accommodate either two standard or two GD2 actuators. This arrangement is used in conjunction with 440K-A04N accessory. 440J-A03N 2-Opto-electronics Safety Switches 440J-A02N Plate Trojan Interlock Enabling Switch mounted on 440J-A03N, shown with two standard actuators The U-shaped 440J-A04N can accommodate two interlocks: either 440K-MT or 440K-T. Using the 440J-A03N plate with dual actuators, a total of eight contacts, four in each switch, can be made available for the safety and control system. The MT-GD2 with the manual latch release should be used for horizontal actuator mounting. The Trojan should only be used with vertical mounting. To use the 440K-T (Trojan 6 or T15), the head must be rotated 180. The Trojan GD2 models cannot be used with the 440J-A02N as its head cannot be rotated. The recommended method for single-switch mounting is to use the 440K-MT (MT-GD2) with the latch release. The latch holds the contacts closed when the enabling switch is bumped or rattled. An alternative is to use the 440K-T (Trojan 6 or T15) with a vertical mounting. The holding force of these interlocks is enough to keep the contacts closed under minor bumps and rattles. Logic Power 4-21

22 Enabling Switches Overview Application Considerations General 1-2-Opto-electronics Safety Switches Logic Power 440J-A04N Dual Interlock Switches Provide Eight Contacts Safety system designers will quickly realize that the enabling device by itself is easy to understand; it is simply a set of contacts. The application of the enabling device into a machine safeguarding system is the challenge. Consideration must be given to the following: 1. Setting the machine in reduced performance mode. In some cases, the speed or other characteristic of the machine must be reduced to allow the operator to avoid the hazard by releasing or squeezing the trigger switch. The control system must be designed so that the machine is not changed back to normal performance during the enabling task. A key-operated mode selector switch is one method of setting the machine in a reduced performance mode. The operator selects reduced mode and then removes the key from the switch, taking the key with him or her. Holding the trigger switch then allows the hazard to operate in a reduced mode. 2. Knowing the machine is in reduced performance mode Sensors can be used to determine that reduced performance of the machine is maintained. Position sensors, encoders or other devices, monitored by an appropriated logic device, provide feedback to the control system. If the performance (e.g., operating speed) were to increase beyond a predetermined limit, the control system would execute a stop command. eleasing the enabling device could also be used to execute a stop command. 3. Type of access The safety system architecture will differ depending on whether partial body or full body access is required. When partial body access is required, the enabling device must continuously bypass the primary safeguard (e.g. gate interlock, light curtain, safety mat, or safety scanner). Enabling devices must only bypass one primary safeguard bypassing multiple safeguards with one enabling device must be avoided as access to the hazard may not be detected by the other bypassed safeguards. Enabling Device Enabling Device If full body access is required, consideration must be given to whether the primary safeguard can or must be active during the operation of the enabling device. With the primary safeguard active, additional entries into the hazard area will be detected. If the primary safeguard must remain inactive, administrative procedures must ensure that additional personnel do not enter the hazard area. 4. Multiple Personnel Access When more than one person must access the hazard, all persons must utilize their own enabling device. All enabling devices must be active to energize the hazard. Hazard 4-22

23 Enabling Switches Overview The table below summarizes when additional interlocking devices must be used in conjunction with the enabling device. For partial body access, three cases exist, depending on the type of device being bypassed and the logic unit used by the safety system. 1. The enabling switch can be connected directly across the safeguarding device that has dry contacts. 2. Devices with OSSD outputs, like the GuardShield Light curtain will need a single interlock with four contacts to avoid nuisance faults when a monitoring safety relay is used as the safety system logic device. 3. When a safety PLC is used as the logic device, the enabling device can be connected to separate inputs and internal programming logic can be used to bypass the light curtain when the enabling switch is needed. For full body access, there are two cases, which depend on the logic device used by the safety system. 1. When a safety PLC is used, a single interlock with four contacts is needed. These four contacts are used to interlock the safety system reset function and the machine start function. 2. When a monitoring safety relay is used, two interlocks with four contacts each are needed. Four contacts are used to bypass the primary safeguarding device. Two contacts are used to reset the safety system. Two contacts are used to interlock the machine start control to prevent starting of the machine from the control panel. General Access Type Safeguard Type Logic Device Interlocks equired Partial Body Full Body Dry Contact Interlocks (e.g., Elf, Cadet, Trojan, MT-GD2, Sipha, Ferrogard, 440G-MT, TLS-GD2, Atlas) Devices with OSSD Outputs (e.g., GuardShield Light Curtain, SensaGuard, SafeZone Multizone) All Types Monitoring Safety elay or Safety PLC Safety PLC Monitoring Safety elay Safety PLC Monitoring Safety elay None Single Interlock with Four Contacts Single Interlock with Four Contacts Dual Interlocks, each with Four Contacts 1-2-Opto-electronics Power Logic Safety Switches 4-23

24 Enabling Switches GripSwitch General 1-2-Opto-electronics Safety Switches Logic Power The three position enabling switch can be used as part of the conditions required to allow safe working inside a machine guard, e.g., set-up, maintenance, or troubleshooting. It is lightweight and ergonomically designed for easy use. The standard model includes two independent three-position switches which are actuated by squeezing the trigger. Additional models are available with an optional jog button or dual channel e-stop button. The trigger switch has three positions. The mid-position is the enabled position. Position 1 there is no pressure on the trigger switch, and the safety contacts are open. Position 2 the trigger switch is squeezed to the mid-position, and the safety contacts are closed. This mid-position is the enabled position. Position 3 the trigger switch is fully pressed and the safety contacts are open. When the trigger switch is released from position three back to position one, the safety contacts remain open, as it passes through position two. Features Dual three position enabling switches Lightweight and ergonomic Optional jog and e-stop functions Specifications Safety atings IEC/EN , IEC/EN , IEC/EN Standards , NFPA 79, ANSI B11.19, ANSI15.06, ISO 10218, ISO Safety Classification Cat. 1 Device per EN954-1; Dual channel suitable for Cat. 3 or 4 systems Certifications CE Marked for all applicable directives, culus Listed, BG Outputs Safety Contacts 2 N.C. direct opening action Auxiliary Contacts 1 N.C. Jog Contact 1 N.O. E-Stop 2 N.C. Direct-Opening Action Thermal CurrentI lth 3 A ated Insulation Voltage (Ui) 250V (jog button 125V) Switching Voltage, Min. 5 3V AC/DC Utilization Category 30V DC 125V AC 250V AC 3- Position Switch Terminals 1-2 and 3-4 Monitor Switch Terminals 5-6 E-Stop Switch Terminals 5-6 and 7-8 DC-12 or AC- 12 esistive DC-13 or AC- 15 Inductive DC-12 or AC- 12 esistive DC-13 or AC- 15 Inductive DC-12 or AC- 12 esistive DC-13 or AC- 15 Inductive 2 A 3 A 0.5 A 1 A 1.5 A 0.5 A 2 A 2 A 1 A 1 A 1 A 0.5 A 0.5 A Operating Characteristics Operating Force, Min. Position 2: 15 N (3.37 lbf) approx. Position 3: 50 N (11.2 lbf) max. Direct Opening Force 90 N (20 lbf) Actuation Frequency, Max operations per hour Environmental Enclosure Type ating IP66 Standard Switch (NEMA 6) IP65 Jog Button and E-Stop Switches elative Humidity 45 85% Operating Temperature [C (F)] ( ) Vibration 5 55 Hz, 0.5 mm Shock 10 g Physical Characteristics Wire Size mm2 (24 14 AWG) Cable Size 7 13 mm ( in.) Terminal Screw Torque N m ( ibf in) Conduit Type M20 Material Polyamide (Nylon) PA66 Boot Material NB/PVC Nitrile Blended with PVC Weight [g (lb)] Color 250 (0.55) with E-stop 210 (0.46) standard and jog Black/grey The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. 4-24

25 Enabling Switches GripSwitch Product Selection Standard Switch (No additional buttons) Switch with Jog Button Switch with Emergency Stop Button M20 Conduit with Cable Strain elief 440J-N21TNPM 440J-N21TNPM-NP 440J-N2NTNPM-NE General Note: Base plate included with all switches. ecommended Logic Interfaces Safety Outputs Auxiliary Outputs Terminals eset Type Power Supply Cat. Page No. Single-Function Safety elays for 2 N.C. Contact Switch MS127P 3 N.O. 1 N.C. emovable (Screw) Monitored Manual 24V AC/DC N23135 MS127TP 3 N.O. 1 N.C. emovable (Screw) Auto./Manual 24V AC/DC N23132 Modular Safety elays MS210P Base 2 N.C. only MS220P Input Module MS310P Base MS320P Input Module 2 N.O. 1 N.C. and 2 PNP Solid State emovable Auto./Manual or Monitored Manual 24V DC from the base unit H23176 emovable 24V DC H23178 MS300 Series Output Modules 3 PNP Solid State emovable Auto./Manual Monitored Manual 2 PNP Solid State emovable Note: For additional Safety elays connectivity, see page 5-4. For additional Safety I/O and Safety PLC connectivity, see page For application and wiring diagrams, see page V DC W V DC from the base unit W Opto-electronics Connection Systems 4-Pin Micro (M12) 5-Pin Micro (M12) 8-Pin Micro (M12) Quick Disconnect Quick Disconnect Quick Disconnect Cordset 889D-F4AC- 889D-F5AC- 889D-F8AB- Patchcord 889D-F4ACDM- 889D-F5ACDM- 889D-F8ABDM- eplace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. eplace symbol with 1 (1 m), 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. To connect to ArmorBlock Guard I/O. Safety Switches Power Logic 4-25

26 Enabling Switches GripSwitch Accessories General 1-2-Opto-electronics Safety Switches Mounting bracket suitable for single enabling switch Mounting bracket suitable for one actuator mounted onto switch Includes four flat head screws and one resistorx bit. Mounting bracket suitable for single enabling switch and single safety switch Mounting bracket suitable for two actuators mounted onto switch Includes six flat head screws and one resistorx bit. Mounting bracket suitable for single enabling switch and two safety switches NB/PVC (silicone free) rubber boot kit 440J-A00N 440J-A01N 440J-A02N 440J-A03N 440J-A04N 440J-A10N The bracket has predrilled holes suitable for mounting either the MT-GD2, Trojan 5, or Trojan 6. Please note that the enabling switch, safety switch, and actuator are not supplied with the mounting bracket and are available separately. Logic Power 4-26

27 81 (3.19) Operator Interface Enabling Switches GripSwitch Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. Standard Switch Emergency Stop Button 58 (2.28) 69 (2.72) 47 (1.85) 46 (1.81) 24 (0.95) General 174 (6.85) Jog Button 46 (1.81) 58 (2.28) 13 (0.51) max. M20 x (0.51) max (1.96) 68 (2.67) 86 (3.38) A range of brackets are available to allow the enabling switch to be mounted alone, or with one or two safety switches. A small bracket has already been fitted to the enabling switch onto which the actuator bracket is mounted. An Application Note on the use of the enabling switch in conjunction with a safety switch is available. 20 (0.79) 2-Opto-electronics 50 (1.97) 5.3 (0.21) Dia. (2 holes) 5.2 (0.2) thru csk 10.0 x 90.0% Dia. M5 x 08-6H Safety Switches PVC Coating (Color: Black) 8.6 (0.34) 40.0 (1.57) 40.0 (1.57) 52.0 (2.04) 16 x M5 x 0.8-6H (4.99) (4.49) 4 x 8.0 Thru 53 (2.09) 8.4 (0.33) 6.0 (0.23) 4.0 (0.15) 6.0 (0.23) 7.0 (0.27) 6.0 (0.23) (0.62) 18.0 (0.7) 440J-A01N Single Actuator Bracket Logic Power J-A00N Enabling Switch Mounting Bracket 4.0 (0.15) 6.35 (0.24) 6.35 (0.24) (4.49) 127 (4.99) 440J-A02N Single Safety Switch Plate 4-27

28 Enabling Switches GripSwitch General 1-2-Opto-electronics Safety Switches Logic Power 66.5 (2.611) 82.0 (3.22) 440J-A03N Double Actuator Plate Typical Wiring Diagram Contact Operation Contact Open Contact Closed Cable Termination Quick Disconnect Termination Mating Cordsets 2-Safety A 3-Safety B 84.0 (3.3) 21.5 (0.84) 2 x (2.55) 9.0 (0.35) 100 (3.94) 440J-A04N Double Safety Switch Bracket 43.0 (1.69) 6 x M5 x 0.8-6H Thru Standard With Jog Button With E-Stop Button Position Position Position Position Position Position Position Position Position Terminal No. Terminal Terminal No. No. Squeeze 1-2 Safety A Squeeze 1-2 Safety A Squeeze 1-2 Safety A 5-6 Aux 3-4 Safety B 5-6 Aux 3-4 Safety AB 3-4 Safety B elease 1-2 elease elease elease Press E-Stop A elease Press E-Stop B 7-8 Jog Safety A 4-Safety B 5-Safety B 3-N/A 2-Safety A 1-Safety A 4-Safety B 3-Safety B 8-Jog 4-Safety B 5-Aux 2-Safety A 1-Safety A 7-Jog 6-Aux 3-Safety B 8-E-Stop B 4-Safety B 5-E-Stop A 2-Safety A 1-Safety A 7-E-Stop A 6-E-stop B 889D-F4AC- 889D-F5AC-* 889D-F8AB-* 889D-F8AB-* 1 Brown 1 Brown 1 White 1 White Safety A Safety A Safety A Safety A 2 White 2 White 2 Brown 2 Brown 3 Blue NA 3 Green 3 Green Safety B 4 Yellow 4 Yellow 3 Blue 4 Black 5 Grey 5 Grey Safety B Safety B Aux 4 Black 5 Grey 6 Pink 6 Pink 7 Blue 7 Blue Jog 8 ed 8 ed Safety B E-Stop A E-Stop B 4-28

29 Push Buttons Bul. 800F 22.5 mm Principles Power General Specifications 22.5 mm Front-of-Panel (Operators) Mechanical atings Plastic (Bulletin 800FP) Metal (Bulletin 800FM) Vibration (assembled to panel) Tested at Hz, 1.52 mm displacement (peak-to-peak) max./10 G max. for 3 hr duration, no damage Shock Tested at 1/2 cycle sine wave for 11 ms; no damage at 100 G Degree of protection IP65/66 (Type 3/3/4/4X/12/13) IP65/66 (Type 3/3/4/12/13) Mechanical durability per EN (Annex C) Operating forces (typical with one contact block) Operating torque (typical application with one contact block) Mounting torque Cycles Momentary push buttons, momentary mushroom Cycles Multi-function, selector switch, key selector switch, selector jog, SensEjectTM key selector switch Cycles Non-illuminated push-pull E-stop Cycles Twist-to-release E-stop, illuminated push-pull E-stop, alternate action push buttons Cycles Potentiometer, toggle switch 9-10-Safety Applications Logic Plastic Metal Temperature range (operating) Temperature range (short term storage) Humidity Environmental Flush/extended = 5 N, E-stop = 36 N Mushroom = 9 N Selector switch = 0.25 N m (2.2 lb in) 1.7 N m (15 lb in) 4.4 N m (40 lb in) C ( F) C ( F) 50 95% H from C ( F) Performance Data see page Important-3 of the Industrial Controls catalog. Momentary mushroom operators are IP65. Plastic keyed operators are IP66, Type 4/13; not Type 4X. Operating temperatures below 0 C (32 F) are based on the absence of freezing moisture and liquids, UL ecognized to 55 C (131 F) - Incandescent module Max 40 C (104 F). Product Certifications Certifications U/UL, CSA, CCC, CE Standards Compliance CE Marked NEMA ICS-5; UL 508, EN ISO 13850, EN , EN , EN Terminal Identification EN/IEC Shipping Approvals ABS ohs 4-29

30 Push Buttons Bul. 800F 22.5 mm General Principles 9-10-Safety Applications Logic Power Back-of-Panel Components Standard contact block ratings Low voltage contact block ratings LED Module atings 24V AC 24V DC 120V AC 240V AC Electrical atings A600, Q V AC AC 15, DC 13 to IEC/EN and UL 508, 17V, 5 ma min. 5V, 1 ma DC min. C300, 150, AC 15, DC 13 to EN and UL 508 Nominal Voltage ange Current Draw Frequency 10 29V AC 10 30V DC V AC V AC 31 ma 24 ma 25 ma 22 ma Thermal current 10 A max. enclosed (40 C ambient) to UL508, EN Insulation voltage (Ui) Screw terminal = 690V, spring-clamp = 300V Wire capacity (screw terminal) Wire capacity (spring-clamp terminal) ecommended tightening torque on screw terminals Dielectric strength (minimum) External short circuit protection Electrical shock protection Standard blocks Vibration (assembled to panel) Shock Contact durability per EN (Annex C) Contact operation Low voltage contact blocks N.O. N.C. N.O.E.M. N.C.L.B. N.C.E.B. Push button travel to change electrical state Operating forces (typical) LED Dominant Wavelength LED Luminous Intensity Incandescent maximum wattage Springs Electrical contacts Terminals Single circuit contact block Dual circuit contact block Green ed Yellow Blue White Green ed Yellow Blue White Standard Low voltage Screw Spring-clamp Performance Data see page Important-3 of the Industrial Controls catalog. Low voltage contacts are recommended for applications below 17V, 5 ma. Wires less than #18 AWG (0.75 mm2) may not hold in terminal securely. 50/60 Hz DC 50/60 Hz 50/60 Hz #18 12 AWG ( mm2) Max. (2) #14 AWG or (1) #12 AWG #18 14 AWG ( mm2) One per spring clamp, two spring clamps per terminal N m (6 8 lb in) 2500V for one minute 10 A type gl/gg cartridge fuse to EN or gn (Class J to UL or Class C to UL 248-4) 6 A type gl/gg cartridge fuse to EN or gn (Class J to UL or Class C to UL 248-4) Finger-safe conforming to IP2X Mechanical atings Tested at Hz, 1.52 mm displacement (peak-to-peak) max./10 G max. 6 hr Tested at 1/2 cycle sine wave for 11 ms and no damage at 100 G max cycles N.C. and N.O.E.M. N.O. and N.C.L.B. Illumination Materials Slow double make and break Slow double make and break positive opening Double break / double make, early make Double break / double make, late break positive opening Double break / double make, early break positive opening 3.4 N N 525 nm 629 nm 590 nm 470 nm 780 mcd 780 mcd 600 mcd 168 mcd 360 mcd 2.6 W 1.5 mm (0.060 in.) 2.5 mm (0.1 in.) Stainless steel and zinc coated music wire Silver-nickel Gold-plated over silver Brass Silver-plated brass 4-30

31 Push Buttons Bul. 800F 22.5 mm Material Listing Component For Use with Material Used Panel gasket All operators Nitrile, TPE Diaphragm seal Illuminated push button, non-illuminated push button K-seal Selector switch, key selector switch, push/twist-to-release E-stop, key E-stop, push/pull mushroom Nitrile Diaphragm retainer, return spring I Illuminated push button, non-illuminated push button, momentary mushroom Stainless steel eturn spring II eset, selector switch, key selector switch, alternate action, push/twist-to-release E-stop, key E-stop, push/pull mushroom Automotive industry acceptable silicone Zinc-coated music wire Button cap/mushroom head Non-illuminated push button, momentary mushroom, reset, push/twist-to-release E-stop, key E-stop, push/pull mushroom, multi-function PBT/polycarbonate blend 2-color molded button cap Non-illuminated push button PBT/polycarbonate blend Lens Multi-function Acetal Lens, knob Illuminated push button, illuminated momentary mushroom, illuminated selector switch Polyamide Knob Non-illuminated selector switch Glass-filled polyamide Plastic bezel/bushing I Non-illuminated push button, illuminated push button, momentary mushroom, selector switch, key selector switch, push/twist-to-release E-stop, key E-stop, push/pull Glass-filled polyamide mushroom, multi-function, reset Plastic bezel/bushing II, jam nut Pilot light, reset jam nut, reset pushers Glass-filled PBT Metal bezel/bushing All metal operators Zinc Diffuser Illuminated push button, pilot light Polycarbonate Legend frames Glass-filled polyamide Plastic mounting ring All plastic operators Glass-filled polyamide Metal mounting ring All metal operators Chromated zinc Plastic latch Glass-filled polyamide Metal latch Chromated zinc + stainless steel Plastic enclosure PBT/polycarbonate blend Metal enclosure Aluminum Terminal screws LED module, incandescent module, contact blocks Zinc-plated steel with chromate Terminals LED module, incandescent module, contact blocks Brass with silver-nickel contacts Spring clamps LED module, incandescent module, contact blocks Stainless steel Lamp socket Incandescent module Brass Housing Incandescent module, LED module Glass-filled polyamide Low-voltage terminals Contact blocks Gold-plated silver-nickel contacts Low-voltage spanner Contact blocks Gold-plated silver-nickel contacts Spanner Contact blocks Brass with silver-nickel contacts Boot Toggle Switch, illuminated push button, non-illuminated push button, multi-function illuminated and non-illuminated Automotive industry acceptable silicone General Principles 9-10-Safety Applications Power Logic 4-31

32 Push Buttons Bul. 800F 22.5 mm Emergency Stop Operators General Principles 9-10-Safety Applications Non-Illuminated Twist-to-elease, Push-Pull 60 mm Non-Illuminated Twist-to-elease 800FP-MT64 Twist-to-elease (Trigger Action) 40 mm Non-Illuminated Push-Pull 800FP-MP44 Push-Pull (Trigger Action) Plastic Metal Plastic Metal Color Size Pkg. Quantity FP-MT34 800FM-MT34 ed FP-MT44 800FM-MT44 800FP-MP44 800FM-MP FP-MT64 800FM-MT64 Illuminated Twist-to-elease, Push-Pull 40 mm Illuminated Twist-to-elease 800FP-LMT44 Twist-to-elease (Trigger Action) 40 mm Mushroom Push/Pull 800FM-LMP44 Push-Pull (Trigger Action) Plastic Metal Plastic Metal Color Size Pkg. Quantity FP-LMP34 800FM-LMP34 ed FP-LMT44 800FM-LMT44 800FP-LMP44 800FM-LMP FP-LMT64 800FM-LMT64 800FP-LMP64 800FM-LMP64 LED module required for illumination, can not use incandescent module. Key elease Mushroom Operator Logic Power 40 mm Non-Illuminated Key elease 800FP-MK44 onis Key Lock (Trigger Action) Color Size Pkg. Quantity ed 40 mm 1 800FP-MK44 800FM-MK44 Plastic All emergency stop operators are EN ISO compliant with standard NC, NCLB, or self-monitoring contact blocks. For key options, see the Industrial Controls catalog. Metal 4-32

33 2-Position Push-Pull Operators, Non-Illuminated Twist-to-elease (Trigger Action), Push-Pull (Trigger Action) Operator Interface Push Buttons Bul. 800F 22.5 mm Power Logic General Principles 9-10-Safety Applications 40 mm Trigger Action Twist-to-elease Mushroom 800FP-MT44 40 mm Trigger Action Push-Pull Mushroom 800FP-MP44 90 mm Half-Dome 800FP-MP94 40 mm Mushroom (Trigger Action) Twist-to-elease 40 mm Mushroom (Trigger Action) Push-Pull Plastic Metal Plastic Metal Color Pkg. Quantity ed 1 800FP-MT44 800FM-MT44 800FP-MP44 800FM-MP44 800F P MT4 4 a b c d P M a Operator Construction ound plastic operator (IP66, Type 4/4X/13) ound metal operator (IP66, Type 4/13) MT3 MT4 MT6 MP4 MP9 b Operator Type Push, Twist-to-elease Type 30 mm color cap 40 mm color cap 60 mm color cap Push-Pull Type 40 mm color cap Half-Dome Push-Pull Type 90 mm color cap c Color Cap Color 2 Black 3 Green 4 ed 5 Yellow 6 Blue d Engraving Blank No engraving on cap LE EMO laser engraved E EMO printed All emergency stop operators are EN ISO compliant with standard NC, NCLB, or self-monitoring contact blocks. Only available with red color cap. For EMO guards, see page Only available on 40 mm color cap. Only available on red, 40 mm push, twist-to-release operator type (MT44). Half-dome operators only available with black, red, and yellow color caps. 4-33

34 Push Buttons Bul. 800F 22.5 mm 2-Position Push-Pull Operators, Illuminated Twist-to-elease (Trigger Action), Push-Pull (Trigger Action) General Principles 9-10-Safety Applications 40 mm Mushroom Trigger Action Twist-to-elease 800FP-LMT44 P M 40 mm Mushroom Push/Pull 800FM-LMP44 90 mm Half-Dome 800FP-LMP94 40 mm Mushroom (Trigger Action) Twist-to-elease 40 mm Mushroom (Trigger Action) Push-Pull Plastic Metal Plastic Metal Color Pkg. Quantity ed 1 800FP-LMT44 800FM-LMT44 800FP-LMP44 800FM-LMP44 a Operator Construction ound plastic operator (IP66, Type 4/4X/13) ound metal operator (IP66, Type 4/13) 800F P LMP4 3 LMT4 LMT6 LMP3 LMP4 LMP6 LMP9 a b c b Operator Type Push, Twist-to-elease Type 40 mm color cap 60 mm color cap Push-Pull Type 30 mm color cap 40 mm color cap 60 mm color cap Half-Dome Push-Pull Type 90 mm color cap LED module required for illumination, can not use incandescent module. All emergency stop operators are EN ISO compliant with standard NC, NCLB, or self-monitoring contact blocks. Only available with red color cap. 60 mm version has black arrows; 30 and 40 mm versions have white arrows. When using LED for illumination, a white LED is recommended. Only available with 40 mm Push-Pull color cap (LMP4 from Table b). Half-dome operators only available with red and yellow lens cap colors. c Lens Cap Color Color 3 Green 4 ed 5 Yellow 6 Blue Logic Power 4-34

35 Push Buttons Bul. 800F 22.5 mm 2-Position Non-Illuminated Operators Mushroom, Key elease (Trigger Action) Power Principles 9- Logic 10-Safety Applications General 40 mm Key elease Mushroom 800FP-MK44 2-Position (Trigger Action) 40 mm Mushroom Key elease Plastic Metal Color Pkg. Quantity ed 1 800FP-MK44 800FM-MK44 Note: For onis replacement keys, see the Industrial Controls catalog. Key release mushroom operators use key no F P MK4 4 a b c d P M a Operator Construction ound plastic operator (IP66, Type 4/13) ound metal operator (IP66, Type 4/13) MK4 b Operator Type Key elease Mushroom Type 40 mm All emergency stop operators are EN ISO compliant with standard NC, NCLB, or self-monitoring contact blocks. Keyed operators are IP66, Type 4/13. Not intended for high security applications. Interoperability is possible with certain key/cylinder lock combinations. Consult your local ockwell Automation sales office or Allen-Bradley distributor for interoperability information. For onis replacement keys, see the Industrial Controls catalog. c Lens Cap Color Color 4 ed d onis Key Lock Key No. Blank 3825 (Standard)

36 Push Buttons Bul. 800F 22.5 mm 3-Position Push-Pull Operators, Illuminated & Non-Illuminated Mushroom General Principles 9-10-Safety Applications Illuminated 3-Position Push-Pull 800FM-LMP44E3 Target Table and Operator Position Contact Type Out Center In N.O. O O X N.C.E.B. X O O N.C.L.B. X X O Note: X = Closed/O = Open Contact selection is limited to the following options, consult your local ockwell Automation sales office or Allen-Bradley distributor for other options. Operator Function Operator Type Color Pkg. Quantity Momentary Out, Maintained Center, Momentary In Momentary Out, Maintained Center, Maintained In Non-Illuminated Illuminated Non-Illuminated Illuminated Black Green ed Amber Green ed Blue Clear Black Green ed Amber Green ed Blue Clear 800F M L MM 4 4 E3 a b c d e f FM-MM42E3 800FM-MM43E3 800FM-MM44E3 800FM-LMM40E3 800FM-LMM43E3 800FM-LMM44E3 800FM-LMM46E3 800FM-LMM47E3 800FM-MP42E3 800FM-MP43E3 800FM-MP44E3 800FM-LMP40E3 800FM-LMP43E3 800FM-LMP44E3 800FM-LMP46E3 800FM-LMP47E3 Logic Power M Blank L a Operator Construction ound metal operator (IP66, Type 4/13) b Operator Type Non-Illuminated Illuminated MM MP c Operator Function Momentary Out, Maintained Center, Momentary In Momentary Out, Maintained Center, Maintained In d Cap Size 4 40 mm Plastic e Cap Color 0 Amber 2 Black 3 Green 4 ed 6 Blue 7 Clear Sold as stand-alone operator only. Not available as a composite catalog number. Cannot use N.C. or N.O.E.M. contact blocks with 3-position push-pull operators. Must use N.O., N.C.E.B., or N.C.L.B. contact blocks. Available in integrated LED version only. Available in illuminated only. Available in non-illuminated only. E3 f Positions 3-Position 4-36

37 Push Buttons Bul. 800F 22.5 mm Momentary Push Button Operators, Non-Illuminated Mushroom Power Principles Logic General 40 mm Mushroom 800FP-MM42 60 mm Mushroom 800FP-MM63 40 mm Mushroom 60 mm Mushroom 90 mm Mushroom 800FP-MM Safety Applications Plastic Metal Plastic Metal Color Pkg. Quantity Black 800FP-MM42 800FM-MM42 800FP-MM62 800FM-MM62 Green 800FP-MM43 800FM-MM43 800FP-MM63 800FM-MM63 ed 1 800FP-MM44 800FM-MM44 800FP-MM64 800FM-MM64 Yellow 800FP-MM45 800FM-MM45 800FP-MM65 800FM-MM65 Blue 800FP-MM46 800FM-MM46 800FP-MM66 800FM-MM66 800F P MM4 3 a b c P M a Operator Construction ound plastic operator (IP65, Type 4/4X/13) ound metal operator (IP65, Type 4/13) Momentary mushroom operators are IP65 rated. Only available with black, red, and yellow cap colors. MM4 MM6 MM9 b Size and Operator Type Mushroom Type 40 mm momentary 60 mm momentary 90 mm momentary c Color Cap Color 2 Black 3 Green 4 ed 5 Yellow 6 Blue 4-37

38 Push Buttons Bul. 800F 22.5 mm Momentary Push Button Operators, Illuminated Mushroom General Principles 9-10-Safety Applications P M 40 mm Mushroom 800FP-LMM43 Plastic 40 mm Mushroom Color Pkg. Quantity Green 800FP-LMM43 800FM-LMM43 ed 800FP-LMM44 800FM-LMM44 Yellow 1 800FP-LMM45 800FM-LMM45 Blue 800FP-LMM46 800FM-LMM46 Clear 800FP-LMM47 800FM-LMM47 a Operator Construction ound plastic operator (IP65, Type 4/4X/13) ound metal operator (IP65, Type 4/13) 800F P LMM4 3 LMM4 Momentary mushroom operators are IP65 rated. When using LED for illumination, a white LED is recommended. a b c b Size and Operator Type Mushroom Type 40 mm momentary c Metal Lens Cap Color Color 3 Green 4 ed 5 Yellow 6 Blue 7 Clear Logic Power 4-38

39 Push Buttons Bul. 800F 22.5 mm Back-of-Panel Components Contact Blocks with Latch Composite 800F P X 0 1 E a b c d e General a c Style N.O. (Normally Open) Circuits P Plastic latch 0 No contact M Metal latch 1 1 N.O. b 2 2 N.O. 3 3 N.O. Contact Block(s) Termination Style 4 4 N.O. 5 5 N.O. X Screw termination 6 6 N.O. Q Spring-clamp termination Six circuits maximum allowable. Power Modules Power Modules with Latch Composite 800F M N 3 G a b c d N.C. (Normally Closed) Circuits 0 No contact 1 1 N.C. 2 2 N.C. 3 3 N.C. 4 4 N.C. 5 5 N.C. 6 6 N.C. Specialty Contact Block(s) Blank Standard blocks V Low voltage QuadCONNECT E N.O. early make L N.C. late break B N.C. early break S N.C. self-monitoring d e Principles 9-10-Safety Applications P M D N Q a Style Plastic latch Metal latch b Power Module Type Incandescent module, screw termination Integrated LED module, screw termination Integrated LED module, spring-clamp termination c Voltage 0 No bulb 1 6V AC/DC 2 12V AC/DC 3 24V AC/DC 4 48V AC/DC 5 120V AC 7 240V AC C G Y W B d Lamp Color Incandescent ed LED Green LED Amber LED White LED Blue LED LED modules for use with all illuminated operators. Incandescent module for use with pilot lights, momentary push buttons, and momentary mushroom operators only. Four circuits maximum allowable when power module is used. Do not stack contact block on power module. Only available for incandescent module. Only available for integrated LED module. For best illumination results, LED color should match lens color. For yellow operator, select a white LED. Logic Power 4-39

40 Push Buttons Bul. 800F 22.5 mm Back-of-Panel Components, Continued General Principles 9-10-Safety Applications Power Modules with Contact Blocks and Latch Composite P M D N Q 800F P N 5 X 1 0 E a Style a b c d e f g h Plastic latch Metal latch b Power Module Type Incandescent module, screw termination Integrated LED module, screw termination Integrated LED module, spring-clamp termination Voltage 0 No bulb 1 6V AC/DC 2 12V AC/DC 3 24V AC/DC 4 48V AC/DC 5 120V AC 7 240V AC c C G Y W B d Lamp Color Incandescent ed LED Green LED Amber LED White LED Blue LED Contact Block(s) Termination Style X Screw termination Q Spring-clamp termination N.O. (Normally Open) Circuits 0 No contact 1 1 N.O. 2 2 N.O. 3 3 N.O. 4 4 N.O. e f N.C. (Normally Closed) Circuits 0 No contact 1 1 N.C. 2 2 N.C. 3 3 N.C. 4 4 N.C. Blank V E L S g h Specialty Contact Block(s) Standard blocks Low voltage QuadCONNECT N.O. early make N.C. late break N.C. self-monitoring Four circuits maximum allowable when power module is used. Do not stack contact block on power module. LED modules for use with all illuminated operators. Incandescent module for use with pilot lights, push buttons, and momentary mushroom operators only. Only available for incandescent module. Only available for integrated LED module. For best illuminated results, LED should match lens color. For yellow operator, select a white LED. Logic Power 4-40

41 Push Buttons Bul. 800F 22.5 mm Back-of-Panel Components, Continued Other Metal Mounting Latch These are zinc-plated, metal die cast mounting latches. Note: Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Pkg. Quantity F-ALM General 800F-ALM Note: Sold only in multiples of 100. Order (quantity of) 100 to receive one package of 100 pieces F-ALM-BP Plastic Mounting Latch Note: Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces F-ALP Principles 800F-ALP 800F-X10 Note: Sold only in multiples of 100. Order (quantity of) 100 to receive one package of 100 pieces. Contact Block Note: Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Latch not included. Note: Sold only in multiples of 100. Order (quantity of) 100 to receive one package of 100 pieces. Latch not included. For use with 800FP-CB_ and 800FP-CC_ operators. For use with 800FP-CC_ operators. Only for use with 4-position selector switch, 4-position toggle switch, or 3-position push-pull operator. Cannot stack. Cannot be used in a composite catalog number. eplacement screws are available ( 800F-AS1) Contact Type F-ALP-BP Pkg. Quantity N.O. 800F-X10 N.C. 800F-X01 N.O. low voltage QuadCONNECT 800F-X10V N.C. low voltage QuadCONNECT 800F-X01V N.O.L.M. 800F-X10N N.O.E.M. 800F-X10E N.O.E.E.M. 800F-X10M N.C.L.B. 800F-X01L N.C.E.B. 800F-X01B Self-Monitoring 800F-X01S Dual circuit of 2 N.O. 800F-X20D Dual circuit of 2 N.C. 800F-X02D 10 Dual circuit of 1 N.O.-1 N.C. 800F-X11D N.O. with stab terminals 800F-X10T N.C. with stab terminals 800F-X01T N.O. spring-clamp 800F-Q10 N.C. spring-clamp 800F-Q01 N.O. spring-clamp low-voltage QuadConnect 800F-Q10V N.C. spring-clamp low-voltage QuadConnect 800F-Q01V N.O.E.M. spring-clamp 800F-Q10E N.C.L.B. spring clamp 800F-Q01L N.C.E.B. spring-clamp 800F-Q01B ing lug N.O. 800F-10 ing lug N.C. 800F-01 N.O. 800F-X10-BP N.C F-X01-BP 9-10-Safety Applications Logic Power 4-41

42 Push Buttons Bul. 800F 22.5 mm General Principles 9-10-Safety Applications Back of Panel Components, Continued Other Volts Pkg. Quantity No bulb 800F-D0C Incandescent Module 6V AC/DC 800F-D1C For use with pilot lights, push buttons, and 12V AC/DC 800F-D2C momentary mushroom operators. Note: Sold in multiples of 10. Order (quantity 24V AC/DC F-D3C of) 10 to receive one package of 10 pieces. Latch not included. 48V AC/DC 800F-D4C 800F-D3C 120V AC/DC 800F-D5C Integrated LED Module For use with all illuminated devices. For best results, LED should match lens color. For amber operators, use yellow LED. Note: Sold in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Latch not included. 24V AC/DC 800F-N3x 120V AC 800F-N5x 240V AC 800F-N7x 24V AC/DC spring-clamp 800F-Q3x 120V AC spring-clamp F-Q5x 240V AC spring-clamp 800F-Q7x 800F-N3G 24V AC/DC ring lug 800F-3x Contact Material Pkg. Quantity N.O. 800F-BX10 N.C. 800F-BX01 N.O. low voltage Base Mounted Contact Block 800F-BX10V QuadCONNECT Base mounted contact blocks can be used in plastic or metal enclosures. N.C. low voltage F-BX01V Note: Sold only in multiples of 10. Order QuadCONNECT (quantity of) 10 to receive one package of 10 N.O.E.M. 800F-BX10E pieces. Latch not included. N.C.L.B. 800F-BX01L N.O. spring-clamp 800F-BQ10 800F-BX01 N.C. spring-clamp 800F-BQ01 Base Mounted Integrated LED Module Base mounted modules can be used in plastic or metal enclosures. For best illumination results, LED should match lens color. Note: Sold in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Latch not included. Volts Pkg. Quantity 24V AC/DC 800F-BN3x 120V AC 800F-BN5x 240V AC 800F-BN7x 24V AC/DC spring-clamp 800F-BQ3x V AC spring-clamp 800F-BQ5x 800F-BN3 240V AC spring-clamp 800F-BQ7x To complete the cat. no., replace the x with one of the following letters for the desired color: Y = Amber, = ed, G = Green, B = Blue, W = White. Cannot be used in a composite catalog number. eplacement screws are available ( 800F-AS1) Logic Power 4-42

43 Push Buttons Bul. 800F 22.5 mm Assembled Stations General 1-Hole Yellow Enclosure E-Stop Station 800F-1YP4 Enclosure Material Quick Connect Operator Type Illumination Voltage Plastic N/A AC Micro DC Micro Twist-to-elease 40 mm Key elease 40 mm Twist-to-elease 60 mm Twist-to-elease 40 mm Non-Illuminated Contact Configuration PG Knockouts Metric Knockouts 1 N.C. 800F-1YP1 800F-1YM1 1 N.O. / 1 N.C. 800F-1YP2 800F-1YM2 2 N.C. 800F-1YP3 800F-1YM3 1 N.C. 800F-1YP4 800F-1YM4 1 N.O. / 1 N.C. 800F-1YP5 800F-1YM5 2 N.C. 800F-1YP6 800F-1YM6 2 N.C. 800F-1YP7 1 N.O. / 2 N.C. 800F-1YP8 24V AC/DC 800F-1YML1 120V AC 1 N.C. 800F-1YML2 240V AC 800F-1YML3 5-pin 2 N.C. Non-Illuminated Low voltage 800F-1YMQ53V 6-pin 1 N.O. / 2 N.C. 800F-1YMQA 4-pin Non-Illuminated/EMO/Guard 1 N.C. 800F-NX1 Non-Illuminated 1 N.C. 800F-1YMQ1 1 N.O. / 1 N.C. 800F-1YMQ2 800F-1YMQ3 Non-Illuminated/EMO/Guard 2 N.C. 800F-1YMQ3VEG 5-pin Non-Illuminated 800F-1YMQ3V 4-pin Non-Illuminated 1 N.C. 800F-1YMQ41 24V AC/DC 1 N.O. / 1 N.C. 800F-1YMQ44 24V AC/DC 1 N.O. / 1 N.C. 800F-1YMQ4 Mini 120V AC 1 N.O. / 1 N.C. 800F-1YMQ5 eceptacle 240V AC 1 N.O. / 1 N.C. 800F-1YMQ6 6-pin 24V AC/DC 1 N.O./1 N.C. 800F-1MYMQ4 Metal 120V AC 1 N.O./1 N.C. 800F-1MYMQ5 240V AC 1 N.O./1 N.C. 800F-1MYMQ6 Please reference Assembled Station Pin Out Chart on page Hole Grey Enclosure E-Stop Station Enclosure Material Quick Connect Operator Type Illumination Voltage Contact Configuration Metal N/A Grey Enclosure Assembled Stations Twist-to-elease 40 mm Key elease 40 mm Non-Illuminated Enclosure Material Quick Connect Operator Type Illumination Voltage Contact Configuration 1-Hole Plastic 2-Hole Plastic 3-Hole Plastic N/A PG Knockouts Metric Knockouts 1 N.C. 800F-1MM1 1 N.O. / 1 N.C. 800F-1MM2 2 N.C. 800F-1MM3 1 N.C. 800F-1MM4 1 N.O. / 1 N.C. 800F-1MM5 2 N.C. 800F-1MM6 PG Knockouts Metric Knockouts Black Push Button 1 N.O. 800F-1PP1 800F-1PM Position Selector Switch 1 N.O. 800F-1PP2 800F-1PM2 "OFF-ON" 2-Position Selector Switch 1 N.O. / 1 N.C. 800F-1PP3 800F-1PM3 (Flush Black) Non-Illuminated 1 N.O. 800F-1PP4 Start and Stop Push Buttons (Flush Black) O (Extended ed) (Flush Black) 1 N.O./1 N.C. 800F-2PP1 Principles 9-10-Safety Applications Logic Power 4 N.O./1 N.C. 800F-3PP1 4-43

44 Push Buttons Bul. 800F 22.5 mm Assembled Stations, Continued 90 mm Enclosed Stations General Principles 9-10-Safety Applications Enclosure Material Quick Connect Operator Type Illumination Voltage 1-Hole, Yellow Plastic 1-Hole, Grey Plastic N/A Assembled Station Pin Out Chart ed half dome ed 90 mm momentary Black 90 mm momentary Contact Configuration PG Knockouts Metric Knockouts 1 N.C. 800F-1YP1HD 800F-1YM1HD Non-illuminated 1 N.O./1 N.C. 800F-1YP2HD 800F-1YM2HD 2 N.C. 800F-1YP3HD 800F-1YM3HD 24V AC/DC 800F-1YML1HD 120V AC 1 N.C. 800F-1YML2HD 240V AC 800F-1YML3HD Non-illuminated 1 N.C. 800F-1YP1M94 800F-1YM1M94 1 N.O./1 N.C. 800F-1YP2M94 800F-1YM2M94 2 N.C. 800F-1YP3M94 800F-1YM3M94 1 N.O./1 N.C. 800F-1PP2M92 800F-1PM2M92 Logic Power Connector Style / No. of Pins Location 1 A to Pin # B to Pin # Location 2 C to Pin # D to Pin # Location 3 E to Pin # F to Pin # G to Pin # 800F-1YMQ53V AC Micro / 5-pin BX01V 1 2 BX01V F-1YMQA AC Micro / 6-pin BX BX BX F-NX1 BX01 1/4 2/3 800F-1YMQ1 BX01 1/4 2/3 800F-1YMQ2 DC Micro / 4-pin BX10V 2 4 BX01V F-1YMQ3 BX01V 1 3 BX01V F-1YMQ3VEG BX01V 1 3 BX01V F-1YMQ3V DC Micro / 5-pin BX01V 1 2 BX01V F-1YMQ41 BX Mini eceptacle / 4-pin 800F-1YMQ44 BX10 1 J BX BN3 3 J J 800F-1YMQ4 BX10 1 J BX BN3 2 J J 800F-1YMQ5 BX10 1 J BX BN5 2 J J 800F-1YMQ6 BX10 1 J BX BN7 2 J J Mini eceptacle / 6-pin 800F-1MYMQ4 BX10 1 J BX BN3 2 J J 800F-1MYMQ5 BX10 1 J BX BN5 2 J J 800F-1MYMQ6 BX10 1 J BX BN7 2 J J J = Jumper 4-44

45 Push Buttons Bul. 800F 22.5 mm Guards Type Pkg. Quantity Protective ing for use with non-illuminated 2-position momentary and illuminated/non-illuminated 3-position mushroom operators (40 mm only) Shiny metal Black 800F-AMG 800F-AMGB General 800F-AMG Yellow Metal 800F-AMGY Plastic Guard for use with the following operators: 40 mm E-stop (SEMI Standards Compliant) 40 mm illuminated/non-illuminated alternate action and momentary operators 60 mm illuminated/non-illuminated momentary operators Selector switches (standard knob and key operated) Potentiometers Yellow, round 800F-A6P5 1 Principles 800F-A6P5 800F-AMEGY Narrow Plastic Guard for use with the following operators: Illuminated and non-illuminated momentary mushroom operators (40 mm) only Bul. 800FD monolithic E-stops (SEMI standards compliant) Flush/extended/guarded push buttons Alternate action operators Selector switches (standard knob and key operated) Potentiometers Yellow 800F-AMEGY 9-800F-AMMG 40 mm Protective Guard used with illuminated and non-illuminated momentary mushroom operators (40 mm) only. Shiny Metal 800F-AMMG 10-Safety Applications Emergency Stop Legend Plates 15Y 15YS 16Y a Size/Color (Yellow) 60 mm round (30.5 mm mounting hole) 60 mm round (22.5 mm mounting hole) 90 mm round (22.5 mm mounting hole) Blank E112 F112 G112 T112 S112 B F 15YS b a Text No text EMEGENCY STOP AÊT D UGENCE NOT AUS AESTO EMEGENZA PAADA DE EMEGENCIA EMEGENCY STOP, AÊT D UGENCE, PAADA DE EMEGENCIA Sold only multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces. Not for use with base mounted contact blocks. Not available on 15YS version. Text printed on the 15Y version only. Text printed on the 15YS & 16Y versions only. b M112 D112 N112 W112 A112 L112 H F-15YSE112 b (cont'd) Text 22.5 mm mounting hole NOT AUS, AESTO EMEGENZA, AÊT D UGENCE EMEGENCY STOP, AÊT D UGENCE, NOT AUS NOODSTOP NÖDSTOPP, EMEGENCY STOP NØDSTOPP, EMEGENCY STOP NØDSTOP NEYÐASTOPP, NEYÐASTOPP NÖD-STOP, HÄTÄ-SEIS, NÖD-STOP Logic Power 4-45

46 Push Buttons Bul. 800T 30.5 mm General Principles 9-10-Safety Applications Logic Power Non-Illuminated 2-Pos. Push-Pull 800T-FX6D4 Illuminated 2-Pos. Push-Pull 800T-FXP16A1 2-Pos. Push-Pull / Twist 800T-FXT6D4 2-Pos. Push-Pull/Twist 800T-FXTP16A1 2-Pos. Push-Pull / Twist 800H-FXT6D4 2-Pos. Push-Pull/Twist 800H-FXTP16A1 The Bulletin 800T and 800H 30.5 mm Emergency Stop devices provide increased reliability. E-stops with normally closed late break contacts comply with EN418 and IEC standards. This means the operator will latch when actuated before the contacts will change state. Application flexibility is offered with 2-position push-pull or 2-position push-pull/twist release configurations. Non-illuminated and illuminated operator options are available. Contact block versions are also available that provide IP2X finger-safe protection. ockwell Automation also offers Self-Monitoring contact blocks (SMCB) which feature enhanced E-stop safety for critical process control applications. The SMCB monitors whether or not it is properly installed on the operator so that the normally closed contacts will open when the E-stop is actuated. If the SMCB is separated from the operator for any reason, the controlled circuit will automatically open. Features 30.5 mm mounting hole Type 4/13 watertight/oiltight (Bul. 800T) Type 4/4X/13 corrosion-resistant/watertight/oiltight (Bul. 800H) Heavy industrial stations and operators Specifications Contact ratings Dielectric strength Electrical design life cycles Vibration Shock Degree of protection Mechanical design life cycles (Push-pull/twist-to-release) Contact operation Wire gauge/terminal screw torque Typical operating forces 2-position push-pull Twist-to-release or push-pull Contact blocks Electrical atings efer to the contact ratings tables below. 2200V for one minute, 1300V for one minute (Logic eed) at max. rated load, at max. rated load (Logic eed) Mechanical atings Standard Logic eed Sealed switch Stackable sealed switch Hz 1.52 mm displacement (peak-to-peak) max./10 G max. (except Logic eed) 1/2 cycle sine wave for 11 ms 25 G (contact fragility) and no damage at 100 G Type 1/4/12/13 (Bul. 800T); Type 1/4/4X/12/13 (Bul. 800H); EN/IEC IP66/ min. Shallow, mini, and low voltage contact blocks: Slow, double make and break Logic eed and sealed switch contact blocks: Single break magnetic #18 12 AWG / 6 8 lb in 7.5 lbs max. push or pull 9 lbs max. push or pull 30 in oz. max. twist, 6 in oz. minimum return 1 lb 1 lb max. 3 lbs max. at in plunger travel 1 lb max. Environment Temperature Operating F ( C) range Storage F ( C) Note: Operating temperatures below freezing are based on the absence of moisture and liquids. Contact your local ockwell Automation sales office or Allen-Bradley distributor for use in lower temperature applications. Humidity 50 95% H from F (25 60 C) per Procedure IV of MIL- STD-BIOC, Method cycling test Standard Contact atings Minimum: 24V 24 ma Maximum thermal continuous current I th 10 A AC/2.5 A DC. Bulletin 800T and 800H units with 800T-XA contacts have ratings as follows: Max. Opertnl. Volts Ue Utilization Category ated Operational Currents IEC NEMA Volts Ue Make Break AC 600 AC-15 A600 DC 600 DC-13 Q VA 60 A 60 A 69VA 2.5 A 720VA 720VA 10 A For applications below 24V/24 ma, PenTUFF or Logic eed contacts are recommended. Self-Monitoring is a trademark of ockwell Automation, Inc. 4-46

47 Push Buttons Bul. 800T 30.5 mm 2-Position Push-Pull and Push-Pull/Twist elease, Non-Illuminated Note: A jumbo or large legend plate is recommended, if space allows. Operator Position Type 4/13 Type 4/4X/13 Push-Pull/Twist Push-Pull/Twist Button Push-Pull elease elease Contact Type Out In Color N.C.L.B. X O ed 800T-FX6D4 800T-FXT6D4 800H-FXT6D4 N.O. - O X N.C.L.B. X O ed 800T-FX6A1 800T-FXT6A1 800H-FXT6A1 N.C.L.B. - N.C.L.B. X X O O ed 800T-FX6A5 800T-FXT6A5 800H-FXT6A5 S.M.C.B. X O ed 800TC-FX6D4S 800TC-FXT6D4S 800HC-FXT6D4S N.O. - S.M.C.B. S.M.C.B. - S.M.C.B O X X X X O O O ed 800TC-FX6A1S 800TC-FXT6A1S 800HC-FXT6A1S ed 800TC-FX6A5S 800TC-FXT6A5S 800HC-FXT6A5S General Principles Note: X = Closed/O = Open Note: Emergency stop push buttons are compliant with EN 418 and EN/IEC Standards when using N.C.L.B. contact blocks. Note: These caps are only available in plastic. 2-Position Push-Pull and Push-Pull/Twist elease Units, Illuminated Note: A jumbo or large legend plate is recommended, if space allows. 9- Operator Position Type 4/13 Type 4/4X/13 Push-Pull elease Push-Pull/Twist elease Push-Pull/Twist elease Maintained Maintained Type Lamp Type Volts Color Contacts Out In Full Voltage Incandescent 24V AC/DC N.O T-FXQ24A1 800T-FXTQ24A1 800H-FXTQ24A1 O X 120V AC ed N.C.L.B. 800T-FXQH10A1 800T-FXTQH10A1 800H-FXTQH10A1 LED X O 24V AC/DC 800T-FXQH24A1 800T-FXTQH24A1 800H-FXTQH24A1 Transformer 120V AC 800T-FXP16A1 800T-FXTP16A1 800H-FXTP16A1 Incandescent 240V AC N.O. - O X 800T-FXP26A1 800T-FXTP26A1 800H-FXTP26A1 ed N.C.L.B. 120V AC X O LED 800T-FXPH16A1 800T-FXTPH16A1 800H-FXTPH16A1 240V AC 800T-FXPH26A1 800T-FXTPH26A1 800H-FXTPH26A1 Note: X = Closed/O = Open Note: Emergency stop push buttons are compliant with EN 418 and EN/IEC Standards when using N.C.L.B. contact blocks. Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs. The Self Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically closes when the S.M.C.B. is properly installed onto the E-stop operator. If the S.M.C.B. is separated from the E-stop operator, the N.O. monitoring contact will automatically open. Contact your local ockwell Automation sales office or Allen-Bradley distributor for availability of illuminated E-stops with Self Monitoring Contact Blocks (S.M.C.B.s). 10-Safety Applications Accessories Type Style Color Yellow, Blank 800T-X646 Logic For 800T Buttons Yellow, Emergency Stop 800T-X646EM Emergency Stop Legend Plates For 800H Buttons Yellow, Emergency Stop 800H-W690 Power 4-47

48 Touch Buttons Bul. 800Z General Principles 9-10-Safety Applications 4-Two-Hand Control Device Logic Power General Purpose 800Z-GF2Q5 Heavy Industrial 800Z-HF1 General Purpose 800Z-GL3Q5B Heavy Industrial 800Z-HL1Y Bulletin 800Z Zero-Force Touch Buttons are designed for use by machine control systems requiring the use of two hands. An interlinked sensor surface weaves two capacitive sensors in offset planes for superior product sensitivity. Bulletin 800Z touch buttons are ergonomically designed for ease of operation. Simply touching the surface of the switch will initiate an output. The Bulletin 800Z line can detect the hand through most industrial gloves. The contour of Bulletin 800Z touch buttons serves two purposes; it easily conforms to the shape of the hand while helping prevent defeatability when two-hand control is needed. Two bi-colored diagnostic LEDs provide guidance during operation. The power/fault LED blinks at different rates to provide diagnostic information to the user. The Bulletin 800Z line detects the presence of a hand during power-up, noise, and conductive film build-up over time. Features Internationally rated ergonomic touch buttons Zero force to operate EMC protection Diagnostic LEDs eplaceable relays (heavy industrial design) Load Life Curves for General Purpose Product Line elay Output - Maximum DC Load elay Output - Electrical endurance breaking capacity DC Voltage (V DC) DC Current (A) resistive load Operations 250V AC resistive load Switching Current (A) Specifications Vibration Endurance Mechanical Shock Degree of Protection Operating Force Input Voltage (elay type) Input Voltage (Solid-State type) Electrical Design Life (elay type) On-delay/Off-delay Current Draw (Solid-State type) General Purpose Line ( 800Z-G) Mechanical atings Heavy Industrial Line ( 800Z-H) 10 G, 1.52 mm displacement 100 G (mechanical durability) Type 4/4X/13 IP psi Washdown Zero Electrical atings Type 4/13 IP66 Low Voltage: 10 40V DC, 20 30V AC Full Voltage (800Z-GF): V AC Low Voltage (800Z-GN/GP): 10 30V DC elay Output 200,000 2A inductive 4A resistive elay Output 150,000 5A inductive 2.5 A resistive Off 60 ms max. On 76 ms max. 100 ma at 24V DC = 2.23 W (no external load) Terminal Block atings Degree of Protection IP2X Wire ange #22 12 AWG (0.5 4 mm2) Tightening Torque 9 lb-in. (1N m) Environmental Temperature ange (Operating) C Temperature ange (Storage) C Humidity 95% H from C (full operation) Materials Housing/Guard Valox 357 Gasket BUNA-N 1/16 in. Cork-BUNA-N Connector Certifications Standards Conformity Insulator material (micro connector) = nylon Insulator material (mini connector) = PVC Standards and Certifications cul us, CE, C-TICK, CSA UL508, CSA 22.2 No. 14, UL50, EN/IEC , EN , EN , EN954-1 Load Life Curves for Heavy Industrial Line ated Operating Current (A) elay Output - Maximum load breaking capacity DC inductive load L/=7 ms AC resistive load AC inductive load (pf=0.4) DC resistive load ated Operating Voltage (V) Service life (x10³ operations) elay Output - Electrical endurance 250V AC resistive load 30V DC resistive load 250V AC inductive load (pf=0.4) 30V DC inductive load L/=7 ms ated Operating Current (A) 4-48

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics Table of Contents Emergency Operator Interface Overview...4-2 LIfeline ope Tensioner System (LTS)...4-4 Lifeline 3...4-6 Lifeline 4...4-10 Lifeline 4 Stainless Steel...4-16 Enabling Switches GripSwitch...4-24

More information

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT Safety Guard Locking 440G-MT General 1-2-Opto-electronics 3-Interlock Logic Description The 440G-MT solenoid switch is a positive mode, tongue operated guard locking interlock switch that locks a machine

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply Safety Guard Locking Atlas 5 General 1-2-Opto-electronics 3-Interlock Logic Description The Atlas 5 is a positive-mode, tongue-operated guard-locking interlock switch that locks a machine guard closed

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min Safety Guard Locking TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until

More information

Cable (Rope) Pull Switches Lifeline 4

Cable (Rope) Pull Switches Lifeline 4 Emergency Stop Devices Description The cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The is the only

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max. AUDIN - 8, avenue de la malle - 70 Saint Brice Courcelles - Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr 80T Direct Opening Action Description The 80T Direct Opening

More information

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model

More information

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation

Integral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model

More information

Termination Connector for Cascadable GuardShield Receiver (if it's a standalone pair) with ArmorBlock Guard I/O Connectivity

Termination Connector for Cascadable GuardShield Receiver (if it's a standalone pair) with ArmorBlock Guard I/O Connectivity POC Type 4 Safety Light Curtains GuardShield Termination Connector for Cascadable GuardShield eceiver (if it's a standalone pair) with ArmorBlock Guard I/O Connectivity Face View of Female 5 3 2 4 1 5-pin

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL SAFETY LIGHT SCREENS

CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL SAFETY LIGHT SCREENS SAFETY LIGHT SCREENS CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL Emergency Stop & Stop Control Rope pull emergency stop switches, when used with steel wire rope, provide emergency stop actuation

More information

Compact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration

Compact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration C R US Conforms to EN418, EN292, EN0947-5-1, EN50041, BS504, ISO1850 UL and C-UL listed ER4020 Compact Rope-Activated Emergency Stop Switch Compact size allows this switch to be used on smaller machines

More information

Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45

Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45 Cat with Guardlocking Interlock and TLSZ-GD, C,, PowerFlex 5 + VDC eset & Lock PowerFlex 5 LL L Brown ed Yellow Green Grey Pink White Blue TLSZ-GD D-FAC- X X 5 S5 S Y 6 -GLSP S S L5 5 A P P AX L Gnd S

More information

Description To Be Used With: Dimensions Cat. No. GD2 standard actuator Trojan GD2 Models Only G-A27011

Description To Be Used With: Dimensions Cat. No. GD2 standard actuator Trojan GD2 Models Only G-A27011 R Safety Tongue Trojan T15 Description To Be Used With: Dimensions Cat. No. Standard actuator Trojan T15 Standard Models Only 3-51 440K-A11238 GD2 standard actuator Trojan GD2 Models Only 3-50 440G-A27011

More information

IDEM Solenoid Interlock Safety Switches

IDEM Solenoid Interlock Safety Switches KLP/KLM/KL3-SS Series Housing Solenoid locking, tongue (key) interlock operated Power to unlock 90 degree adjustable head One (KLP) or three (KLM, KL3-SS) 1/2 in. female NPT conduit opening 30mm mounting

More information

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size General 1-Principles 2-Safety s 3-Safety Switches 4-Operator The Guard safety mat is a pressure-sensitive safeguarding product that is designed to detect the presence of people on its sensing surface.

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety

More information

Heavy-Duty Safety Interlock Switch with Guard Door Locking

Heavy-Duty Safety Interlock Switch with Guard Door Locking C R US Conforms to EN1088, EN60947--1, EN292, EN60204-1 UL and C-UL listed TL8018- Heavy-Duty Safety Interlock Switch with uard Door Locking High locking force of,00 N (1,236 lb.) locks guard door shut

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 78 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

Safety Switches Machine Safety

Safety Switches Machine Safety Safety Switches Machine Safety We develop products and solutions for machine safety The fact that the leading power and automation technology company, ABB, and a leader in machine safety, Jokab Safety,

More information

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

XW Series E-Stops. Safety.  Selection Guide ø22mm XW E-Stops Safety Selection Guide... 288 ø22mm XW E-Stops... 289 www.idec.com/usa/estop XW Series E-Stops Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Table

More information

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web:  - Safety ø22mm XW E-Stops... 277 XW Series E-Stops Overview Interlock Switches Enabling Switches Safety Control ight Curtains AS-Interface Safety at Work Phone: 8.894.412 - Fax: 888.723.4773 - Web: www.clrwtr.com

More information

ø22mm HW Series Control Units Control Units

ø22mm HW Series Control Units Control Units mm HW Series Control Units Control Units HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn eset Category ø40mm

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC

More information

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing IDEM MPC Non-Contact Coded Magnetic MPC Series Plastic Housing MPC-114105 Coded magnetic actuation Compact yet robust fitting suitable for all small guard applications Hygenic screw cap covers ensure suitability

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches Locking Safety Switches HSE HSE Full Size Locking Switches Key features: Plastic Housing: Lightweight 00N locking retention force Available with a red or green indicator Choose from circuit configurations

More information

HS1C Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB ø22mm XW E-Stops Circuit Breakers Terminal Blocks ors Timers elays & Sockets Signaling ights 22mm XW E-Stops Key features: The depth behind the panel can be as little as 46.4 mm for 1 to 4 contacts (with

More information

22mm XW E-Stops. UL File #E68961 CCC No Specifications

22mm XW E-Stops. UL File #E68961 CCC No Specifications XW Series 22mm XW E-Stops Key features: The depth behind the panel is only 48.7 mm for 1 to 4 contacts (with terminal cover) for illuminated and non-illuminated units. IDEC s original Safe break action

More information

Pneumatic Isolation Module

Pneumatic Isolation Module Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,

More information

Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch

Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document

More information

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches Standard Interlock Safety Switches HS6B HS5E-K Key Locking Safety Key features: Head removal detection circuitry. High-security pin tumbler key types are used. Sixteen types of key numbers are available,

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A Characteristics Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600, CSA A600-Q600 Standard version : TH Ambient air

More information

Programmable Logic Controller. Mat Nor Mohamad

Programmable Logic Controller. Mat Nor Mohamad Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

Safety detection solutions

Safety detection solutions General, Preventa XY C Presentation are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob

More information

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

Hall Coded Non-contact Safety Switches. Model Number Structure

Hall Coded Non-contact Safety Switches. Model Number Structure Hall Coded Non-contact Safety Switches FS-TGR-N@C Hall coded non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available.

More information

Sense7-series Non-contact coded safety switch

Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please

More information

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS 1 P/N: PS-P INSTALLATION & SETTING INSTRUCTIONS YELLOW INDICATION FLAG: P/N STP-F The Indication Flag should be fitted when there is more than one switch used on the conveyor as noted in AS1755-2000 Clause

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Machine & Process Safeguarding Solution Selection Guide

Machine & Process Safeguarding Solution Selection Guide Machine & Process Safeguarding Solution Selection Guide 2015-2016»» Expert Area»» Light Curtains»» Laser Scanners»» Programmable Safety Systems»» Mats and Edges»» Door Switches»» Emergency Stop Devices»»

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (00) 6-0 www.cmafh.com Safety Interlock Switches DSL-N Super Small Class 6-Contact uard Lock Safety-Door Switch

More information

HS1E-K Interlock Switches with Solenoid (3-circuit)

HS1E-K Interlock Switches with Solenoid (3-circuit) HS1E-K Interlock Switches with Solenoid (-circuit) Dual main circuit + lock monitor circuit provide more safety to your system Basic unit and solenoid unit in one housing Lightweight plastic housing All

More information

FS1A Safety Controller

FS1A Safety Controller Complies with key safety standards In Human Machine Interface (HMI) environment, ensuring the safety of operators and machines is given the top priority. Enabling switches, emergency stop switches, light

More information

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit C Conforms to EN94-1, EN1088, EN60204-1 UL and C-UL listed Description R US Compact Coded Magnetic Safety Interlock Switch and Control Unit Dual channel, fully monitored system; meets Category 3 when single

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

Installation Instructions - K-Safe-T-Rip Belt Rip Detector

Installation Instructions - K-Safe-T-Rip Belt Rip Detector Kinder Australia product: Preferred Setup Instructions Note: The correct Belt Rip pick up detachment operation of the Rip Socket, is in a sideways motion to the attachment point. This means once the Socket

More information

Hinge Wing Safety Interlock Switches

Hinge Wing Safety Interlock Switches Hinge Wing Safety Interlock Switches SI-HG80 Series Safety Interlock Switches Encapsulated in a Load-Bearing Hinge Inline QD Fitting Right-Angle QD Fitting Features Safety switch is integrated and encapsulated

More information

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions UGB4-KLT with Sliding Handle Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions UGB2-KLT Application: The UGB-KLT Gate Box (incorporating an RFID interlock switch) is designed to fit

More information

ED SERIES SAFETY LIMIT SWITCH

ED SERIES SAFETY LIMIT SWITCH Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make

More information

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series DESCRIPTION MICRO SWITCH GKL/R Series switches are a heavy-duty key operated solenoid safety interlock switch incorporating a key trapping mechanism.

More information

Section. Safety Products Selection Guide...B-2

Section. Safety Products   Selection Guide...B-2 Section B New New New Selection Guide...B-2 : Door Interlock Switches HS6B Sub-Miniature...........-5 HS5B Miniature...............-8 HS2B Full Size, Molded Plastic.-14 HS1B Full Size, Cast Aluminum..................-18

More information

Contents. Part no.: MLC510R Safety light curtain receiver

Contents. Part no.: MLC510R Safety light curtain receiver Part no.: 68001315 MLC510R30-1500 Safety light curtain receiver Figure can vary Contents Technical data Suitable transmitters Dimensioned drawings Electrical connection Circuit diagrams Operation and display

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

ABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products

ABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products ABB JOKAB SAFETY Products Material handling industries Machine safeguarding products Safety solutions for material handling Continuous operation and sustainability The costs associated with downtime in

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS Door Monitoring Trojan 5 Interlock Switch, Guardmaster Safety Relay, PowerFlex 525 Drive with Safe Torque-off Table of Contents: Introduction 6-122

More information

Automation - Lift - Handling System - Atex

Automation - Lift - Handling System - Atex Automation Lift Handling System Atex GIOVENZANA INTERNATIONAL B.V.: AUTOMATION TECHNOLOGIES AUTOMATION The solutions offered by Giovenzana are the results of the market analysis of industrial electrical

More information

PRODUCT SPECIFICATION. Stack Lights. Series.

PRODUCT SPECIFICATION. Stack Lights. Series. PRODUCT SPECIFICATION Stack Lights Series www.wernerelektrik.com Light Color Significance... Specifications... Functional Specification... Model Number Structure - Stack Lights... Model Number Selection...

More information

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content Pull-wire emergency-stop switches 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

Pendant control stations

Pendant control stations : pages 30075/3 to 30075/6 Characteristics Environment Conforming to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, VDE 0660-200 Approvals Protective treatment NEMKO. Special version : UL Listed A600-Q600,

More information

Safety door-handle system STS

Safety door-handle system STS Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks

More information

Power Contactor with Mirror Contacts

Power Contactor with Mirror Contacts LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z 11 15 1 LLAME SN

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Enabling Switches. Safety. Selection Guide

Enabling Switches. Safety.   Selection Guide Safety Selection Guide... 365 Panel Mount... 366 HE1B Series... 366 HE2B Series... 368 HE3B Series... 371 HE5B Series... 374 HE6B Series... 377 Grip... 380 HE1G Series... 380 HE1G-L Series... 384 HE2G

More information

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically

More information

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19 1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double

More information

Safety. For further information on this product range and to start purchasing online, please scan the QR code. 8-1

Safety. For further information on this product range and to start purchasing online, please scan the QR code. 8-1 Safety Safety Controllers Single Function Safety Relays -2 Programmable Safety Relays -3 Safety Interlocks Mechanical Interlocks -5 Non-Contact Interlocks - Key Exchange Interlocks -11 Presence Sensing

More information

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Catalogue PDE675TCUK October

More information

F3S-TGR-KM15/-KM16/-KH16

F3S-TGR-KM15/-KM16/-KH16 Safety door switches with partially or full stainless steel body F3S-TGR-KM1/-KM16/-KH16 This safety door switches use a stainless steel head or even a full stainless steel body to increase the robustness.

More information

PGS Gripper Double Blank Sensors

PGS Gripper Double Blank Sensors User Instructions Double Blank Sensor Kit Micro Catalog # Pico Catalog # Description SGS40040-K SGS40040P4-K NPN SGS40041-K SGS40041P4-K PNP Note: Whenever any part of the gripper is replaced including

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Installation Instructions: K-Safe-T-Drift

Installation Instructions: K-Safe-T-Drift Micro Switch Installation Sheet Micro Switch Cam Rest Position See Vertical or Horizontal Arm Installation Instructions for Micro Switch activation sequence. Micro Switch Cam Adjustment Screw SW 1 Micro

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE 4 NHP SAFETY REFERENCE GUIDE CONTENTS SAFETY TECHNOLOGY Risk Reduction Options Permanent Fixed Guard 4-02 Interlocked Guard: 4-03 Limit Switches 4-08 Presence Sensing Technology 4-09 Safety Laser Scanners

More information

F3S-TGR-KHL1/-KHL3/-KHL3R

F3S-TGR-KHL1/-KHL3/-KHL3R Safety guard-lock door switches with full stainless steel body F3S-TGR-KHL1/-KHL3/-KHL3R The F3S-TGR-KHL3 safety-door switch keeps medium to large guard doors closed until hazards have been removed. It

More information

Hinge Wing Safety Interlock Switches

Hinge Wing Safety Interlock Switches SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge Safety switch is integrated and encapsulated into a load-bearing hinge, providing a high degree of protection from intentional

More information

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept pg. 3 TS-6 & TS-16 Mini Sensing Edges Low profile with high sensitivity Immediate activation,

More information

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists. /2.0 PURPOSE This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists. The HMS system is a means of preventing hoist operation or movement to

More information

GHG43 Series Control Stations

GHG43 Series Control Stations GHG43 Series Control Stations Nonmetallic or 316L Stainless Steel UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, (A) Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cul) PTB ATEX

More information

Safety Interlock Switches

Safety Interlock Switches Interlock Switches Interlock Switches Selection and Application of Switches..... 186 Flat Pack Style Switches................... 191 Limit Switch Style Switches................. 199 Locking Style Switches....................

More information

MKey9-series Safety Interlock Switch with Guard Locking

MKey9-series Safety Interlock Switch with Guard Locking Original instructions MKey9-series Safety Interlock Switch with Guard Locking ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document

More information

Safety stop buttons Smile, INCA and Compact

Safety stop buttons Smile, INCA and Compact Smile, INCA and are used to safely stop a certain part of a dangerous machine. ABB offers safety stop buttons to suit different needs of connection and communication. Models are available for e.g. external

More information

Safety Interlock Switches

Safety Interlock Switches Safety Interlock Switches ATK ATK Safety Key Selector Switch Key-type selector switch with direct opening mechanism Selector Switch for secure equipment activation during maintenance 0 types of exclusive

More information

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Bulletin 0700-B3 ENGINEERING