420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS
|
|
- Christiana Golden
- 5 years ago
- Views:
Transcription
1 MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within the premix combustion zone* Circular Furnace pening No special cutting of combustion chamber front plate -,00 MBH - PH The Power Flame Model C dual fuel burner presents optimum state-of-the-art design for maximum combustion efficiency and operating dependability. These packaged combustion systems will fire all types of gaseous fuels as well as # or similar distillate liquid fuels. The Model C ir tomizing Burner fires # oil at turndowns up to :, up to 0: on natural gas. Its flame retention firing head incorporates a single air atomizing nozzle assembly for liquid fuels and a nozzle mix multiport combustor for gaseous fuels. ur unique air sandwich firing Low as Pressure Firing Head dded flexibility of application for low gas pressure conditions* head design produces full range stable performance in both positive or negative combustion chambers. perating system adjustments have been minimized to provide troublefree start up and operation. The Model C provides efficient combustion without the aid of refrac- tory or other costly flame support devices. ptions include the premix and low gas pressure firing heads for limited size combustion chamber configurations or low gas pressure conditions. Modular design provides added flexibility for a wide range of optional features. ll Power Flame packaged combustion systems are factory fire-tested to ensure cost effective installation and start up. lpha SystemTM LED indicators, switches and operator annunciator. (ptional additional -light board shown on right.) Characterized Fuel Metering Varicam provides adjustable and accurately repeatable fuel/air ratios throughout the firing range* Total ccess Panel Swing out, easily removable top and front panels give total access to all internal panelmounted components raphic Burner Management System *ptional C Director graphic annunciation of critical functions* C-00 Rev.0
2 The optional Varicam has adjustable setpoints to maintain optimum fuel/air ratios from low to high fire settings. STNDRD EQUIPMENT 0 RPM blower, panel with lights & control switch Pressure regulators, pilot and main gas cocks il valve, nozzle assembly, manual fuel selector switch ir safety switch & leakage test cock as electric pilot and ignition transformer DDED FETURES -Standard -ptional -Not vailable UV Flame Safeguard with prepurge & postpurge with interrupted pilot Modulation with automatic air control Integral stage fuel unit Remote mounted stage fuel unit (single stage for C-C) Dual gas and dual oil safety valves High and Low gas pressure switches ir atomizing compressor set Man/uto switch - manual potentiometer Conforms to UL and UL MDEL CR (For low centerline applications) C-- C-- C--B C-- C--0 C--0(B) C--0 C--0 C--0,000 MBH and below may be replaced by one () proof of closure valve; above,000 MBH one () of the safety valves will include proof of closure feature. MDEL C DIMENSINS (Inches) Standard Models. RTINS & SPECIFICTINS * This dimension may be increased. Consult factory. CPCITY Blower Std. as # il Natural Nominal MotorH.P. as Pump Remote Pressure Burner PH as/mbh Boiler H.P. (0 Train Suction Pump Compressor Required Model B B(R) C C(R) D E Std. *Max H I L S Max. Max. Max. RPM) (In.) Capacity HP ( ) HP (In.W.C.) C-- / / / / 0., 0.0 / /. C-- / / / / 0 0., / / /. C--B / / / / 0., 0.0 / / /.0 C-- 0 / / / / / / / / 0.,0.0 / / /. C--0 0 / / / / / / / / 0.,0 0.0 / /. C--0 0 / / / / / / / /.,0.0 / 0 /. C--0B 0 / / / / / / / /. 0, / 0 /. C--0 / / / / / / / / / / / / 0.0, /. C--0 / / / / / / / / / / /., / 0.0 C--0B / / / / / / / / / / /.,00.0 /. C--0 / / / / / / / / / / / /.,00.0 / 0.0. Capacities listed are based on 0. W.C. positive pressure. For derates, see capacity curves.. t inlet to main manual shutoff cock to obtain P/F certified ratings with standard U.L. gas train. ptional gas trains and combustion heads available for lower pressures. Integral Pump standard on C and C, Remote Pump optional with / HP motor at 0 RPM. C through C Remote Pump standard with / HP motor at 0 RPM. Represented By: 0 South st Street Phone --00 Parsons, KS Fax --0 Web Site: csd@powerflame.com Copyright Power Flame Incorporated 0 Printed in U.S..
3 MDEL C MDEL C HTD FRCED DRFT BURNERS S,000 -,00,000 BTU/HR. Low as Pressure Firing Head dded flexibility of application for low gas pressure conditions* Circular Furnace pening No special cutting of combustion chamber front plate Power Flame s Versatile High Performance as Burner djustable Premix Firing Head Produces optimum fuel-air mixture within the premix combustion zone* The Power Flame Model C gas burner presents optimum state-of-the-art design for maximum combustion efficiency and operating dependability. These packaged combustion systems will fire natural gas and a full range of waste or other gaseous fuels. The Model C HTD (High Turndown) will fire natural gas at turndowns up to 0 to. The flame retention firing head incorporates the nozzle mix multiport combustor and unique air sandwich design to produce full range stable performance in both positive or negative combustion chamber environments. perating system adjustments have been minimized to provide trouble free start up and operating performance. The Model C produces efficient combustion without the aid of refractory or other costly flame support devices. ptional features include the premix and low gas pressure firing heads for limited size combustion chamber configurations or low gas pressure conditions. Modular design produces added flexibility for a wide range of optional features. ll Power Flame packaged combustion systems are factory fire-tested to ensure cost effective installation and start up. lpha System LED indicators, switches and operator annunciator. (ptional additional -light board shown on right.) Characterized Fuel Metering Varicam provides adjustable and accurately repeatable fuel-air ratios throughout the firing range* Total ccess Panel Swing out, easily removable top and front panels give total access to all internal panelmounted components raphic Burner Management System Director graphic annunciation of critical burner functions* *ptional C-00 Rpt.
4 ptional NV Low Nx systems: Induced Flue as Recirculation shown. STNDRD EQUIPMENT lpha System LED (power, demand, main fuel, FS alarm, selectable) and control switch as electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot and main gas pressure regulators ir safety switch DDED FETURES -Standard -ptional -Not vailable Flame Safeguard with UV and intermittent pilot Flame Safeguard with UV and interrupted pilot n-ff diaphragm gas valve with fixed air control manual adjustment Low-Hi-ff motorized gas valve with automatic air control Low-Hi-Low motorized gas valve with automatic air control Modulation with automatic air control (Standard on all C HTD) Dual gas safety valves High and Low gas pressure switches Nova Low Nx systems Customized control systems and accessories Man/uto switch - manual potentiometer-modulation units Conforms to UL MDEL CR (For low centerline applications) C--0 C-- C-- C-- C--B C-- C-- C--B MDEL C C-- C--0 C--0(B) C--0,000 MBH and below may be replaced by one () proof of closure valve; bove,000 MBH one () of the safety valves will include proof of closure feature. C--0 C--0 Burner Model C--0 C-- C-- C-- C--B C-- C-- C--B C-- C--0 C--0(B) C--0 C--0 C--0B C--0 DIMENSINS B / / / / / / / / / / 0 / 0 / 0 / / / / / / / / / B(R) / / / / / C / / / / / / / / C(R) / / D / / / / / / / / / / / / / / / / / / / / / / / / (Inches) Standard Models. Std. E / / / F** / / / / / / / / / / / / / / / / *Max. / / / / / / / / / H / / / / / / / / / / / / I / / / / / / / / / / / / K / / / L / / / / / / / / / / / / S / / / / / / / / / / / / / / / / / / RTINS & SPECIFICTINS CPCITY Nat. as MBH Max. 0,0,0,00,00,0,,0,00,0 0,00,,000,00,00 Nominal Boiler H.P. Max Blower Motor H.P. (0RPM) / / / / / / / 0 Standard as Train Size(In.) / / / / / as Pressure Required (In. W.C.) , South st Street Phone --00 Parsons, KS Fax --0 Web Site: csd@powerflame.com Copyright Power Flame Incorporated 0 Printed in U.S... Capacities listed are based on 0. W.C. positive pressure, except for C--0B, which is rated at +. W.C. Refer to capacity curves for derates based upon combustion chamber pressure.. t inlet to main manual shutoff cock to obtain P/F certified ratings with standard U.L. gas train. ptional gas trains and combustion heads available for lower pressures. * This dimension may be increased. Consult factory. ** This dimension depicts space required to accomodate a standard gas train.
5 MDEL C MDEL C HTD FRCED DRFT BURNERS S LIHT IL,000 -,00,000 BTU/HR. Power Flame s Versatile High Performance as-light il Burner djustable Premix Firing Head Produces optimum fuel-air mixture within the premix combustion zone* Circular Furnace pening No special cutting of combustion chamber front plate Low as Pressure Firing Head dded flexibility of application for low gas pressure conditions* The Power Flame Model C dual fuel burner presents optimum state-of-the-art design for maximum combustion efficiency and operating dependability. These packaged combustion systems will fire all types of gaseous fuels, as well as # or similar distillate liquid fuels. The Model C HTD (High Turndown) will fire natural gas at turndowns up to 0 to. The flame retention firing head incorporates a single nozzle pressure atomizing assembly for liquid fuels and a nozzle mix multiport combustor for gaseous fuels. The unique air sandwich firing head design produces full range stable performance in both positive or negative combustion chambers. perating system adjustments have been minimized to provide troublefree start up and operation. The Model C provides efficient combustion without the aid of refractory or other costly flame support devices. ptions include the premix and low gas pressure firing heads for limited size combustion chamber configurations or low gas pressure conditions. Modular design produces added flexibility for a wide range of optional features. ll Power Flame packaged combustion systems are factory fire-tested. lpha System LED indicators, switches and operator annunciator. (ptional additional -light board shown on right.) Characterized Fuel Metering Varicam provides adjustable and accurately repeatable fuel-air ratios throughout the firing range* Total ccess Panel Swing out, easily removable top and front panels give total access to state-of-the-art, compact DIN rail mounted components *ptional raphic Burner Management System Director graphic annunciation of critical burner functions* C-00 Rev.
6 The optional Varicam has adjustable setpoints to maintain optimum fuel/air ratios from low to high fire settings. STNDRD EQUIPMENT lpha System LED indicators (power, demand, main fuel, FS alarm, customer selectable) & control switch Pressure regulators, pilot and main gas cocks il valve, nozzle assembly, manual fuel selector switch ir safety switch & leakage test cock as electric pilot and gas ignition transformer DDED FETURES -Standard -ptional -Not vailable Flame Safeguard with UV and prepurge with interrupted pilot n-ff diaphragm gas valve with fixed air control manual adjustment Low-Hi-ff motorized gas valve with automatic air control Low-Hi-Low motorized gas valve with automatic air control Modulation with automatic air control Integral stage fuel unit (C, C single stage) Remote mounted stage fuel unit (single stage for C-C) Dual gas B and dual oil safety valves High and Low gas pressure switches Direct spark ignition (oil) Low fire oil start with automatic air control Man/uto switch - manual potentiometer - modulation only Postpurge standard on C--B and all C to C models Conforms to UL and UL MDEL CR (For low centerline applications) C--0 C-- C-- B C-- C-- C-- C--B C--B C-- C--0 C--0(B) C--0,000 MBH and below may be replaced by one () proof of closure valve; above,000 MBH one () of the safety valves will include proof of closure feature. MDEL C C--0 C--0 Burner Model C--0 C-- C-- C-- C--B C-- C-- C--B C-- C--0 C--0(B) C--0 C--0 C--0B C--0 DIMENSINS (Inches) Standard Models. * This dimension may be increased. Consult factory. ** This dimension depicts space required to accommodate a standard gas train. / / / / / / / / / B / / / / / / / / / / / / B(R) / / / / / / / / / C / / / / / / / / / / / / / / / C(R) / / / / / / / / / D / / / / / / E / / / F** / / / / / / / / Std. / / / / / / / / *Max. / / / / / / / / / H / / / / / / / / / / / / I / / / / / / / / / / / / K / / / 0 South st Street Phone --00 Parsons, KS Fax --0 Web Site: csd@powerflame.com Copyright Power Flame Incorporated 0 Printed in U.S.. L / / / / / / / / / / / / S / / / / / / / / / / / / / / / / / / RTINS & SPECIFICTINS # il PH Max CPCITY Natural Nominal as/mbh Boiler H.P. Max. Max. 0.,0.,0.,00 0.0,00.,0 00.0,.0,0.0,00 0.0, ,00 0.0, 0.0, ,00.0,00.0 Blower Motor H.P. (0 RPM). Capacities listed are based on 0. W.C. positive pressure, except for C--0B, which is rated for 0 BHP at +. W.C. Refer to capacity curves for derates based upon combustion chamber pressure.. t inlet to main manual shutoff cock to obtain P/F certified ratings with standard U.L. gas train. ptional gas trains and combustion heads available for lower pressures. Remote Pump Set with 0 () or /0//0 motor, 0 RPM - / HP - C; 0 RPM - HP - C, C; 0 RPM - -/ HP - C, C. For n-ff and modulating firing modes only. Refer to C Manual for capacities on other modes. / / / / / 0 Std. as Train (In.) / / / / / Pressure Pump Suction (PH) as Pressure Required (In. W.C.) ,
Power Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationGAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign
3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot
More informationFD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS
SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,
More informationM SERIES TECHNICAL DATA INFORMATION PACKET
M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical
More information1070 SERIES ULTRA LOW NO X
CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing
More informationS1 SERIES TECHNICAL DATA INFORMATION PACKET
S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationPROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and
More informationManual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.
Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A. 2001 South 21st Street Phone 620-421-0480 Parsons, KS 67357 FAX 620-421-0948 Web Site: http://www.powerflame.com E-Mail: CSD@powerflame.com
More informationMULTIFIRE. High temperature dual fuel burner
MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,
More informationPROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for
More informationIMMERSION FIRED HOT WATER BOILER
918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series
More informationProduct Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures
More information1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X
1500 SERIES LRGE CPCITY ULTR 2 LOW NO X URNER CPILITIES High release rates with moderate air pressure Good turndown with flame characteristics and direction maintained Stable flames can range from highly
More informationD SERIES BURNERS 4.2 TO 42.0 MMBTU/HR
D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler
More informationPROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.
PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationINDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS
Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012
More informationEclipse RatioAir Burners
Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire
More informationStart-up Instructions
RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been
More informationEclipse Vortometric Burners Series HI
Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)
More information1200 SERIES FTR HOT AIR BAFFLE BURNER
CAPABILITIES High release rates with moderate air pressure Good turn down with flame characteristics and direction maintained Stable flames tailored to the job applications can be from highly oxidizing
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from
More informationFeatures Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design
97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This
More informationModel HDS and HDSX Burner
Price: $50.00 US $75.00 Canadian Webster Engineering & Manufacturing Co., L.L.C. 619 Industrial Road, Winfield, KS 67156 Installation, Startup, Operation and Maintenance Manual Model HDS and HDSX Burner
More informationManual JA 1082 Rpt 0409 Copyright Power Flame Incorporated 1989 Printed U.S.A.
Manual JA 1082 Rpt 0409 Copyright Power Flame Incorporated 1989 Printed U.S.A. 2001 South 21st Street Phone 620-421-0480 Parsons, KS 67357 FAX 620-421-0948 Web Site: http://www.powerflame.com E-Mail: CSD@powerflame.com
More informationPROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.
PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,
More information97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel
97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic
More informationField proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility
-.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER
More informationCOMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners
W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure
More informationJR30A-12 J15A-10HTD INSTALLATION & OPERATION JA MANUAL POWER FLAME INCORPORATED
JR30A-12 J15A-10HTD INSTALLATION & OPERATION JA MANUAL POWER FLAME INCORPORATED FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. Do not touch electrical switches. 3. Extinguish any open flame. 4.
More informationKINEMAX. Medium velocity gas or oil burners
KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate
More informationData 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)
More informationX4 Installation and Operation Manual - POWER FLAME INCORPORATED
7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice
More informationDoing more for clean environment and energy saving
Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one
More informationHamilton 3VO Submittal
Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum
More informationCombustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels
Combustion Equipment Combustion equipment for Solid fuels Liquid fuels Gaseous fuels Combustion equipment Each fuel type has relative advantages and disadvantages. The same is true with regard to firing
More informationEconomite RE Series. Power Gas Burners. MADE in the USA
Economite RE Series MADE in the USA Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44"
More information02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.
I EQUIPMENT : GAS/OIL FIRED INDIRECTLY HEATED ROTARY REACTOR. Technical Data : 01. Type : Indirectly heated. 02. Purpose : Heating / Drying / Calcination etc. 03. Feed Size : 0 25mm. 04. Feeder System
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
-.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an
More information7. SERVICING AND COMPONENT ADJUSTMENTS
7. SERVICING AND COMPONENT ADJUSTMENTS General Information on Internal Bypass Oil Systems 1. The system is designed to use 300 PSI pressure at the nozzle inlet at low and high fire (and throughout the
More information1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER
CAPABILITIES Short, compact, clear and bushy flame Suitable for rich gases and most oils 10% to 300% excess air through burner with rich gaseous fuels and light oils 10% to 100% excess air through burner
More informationFD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP
FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP Features of the FD68 Series RUGGED INDUSTRIAL DESIGN SUPERIOR HOUSING Cylindrical windbox design provides
More informationPREMIX TUNNEL BURNERS
FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More informationLow Temperature Burners - STICKTITE and PILOTPAK Nozzles
Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean
More informationBBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction
BBG Gas Beta Burner BBG-1 Edition 02-08 BBG shown with pilot ignition and converging tile options. Designed for low pressure air operation Rugged heavy gauge steel construction Alloy or refractory tile
More informationECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH
Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower
More informationLANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM
LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM Part 1. General 1.01 Description A. This section describes a candlestick flare system for the combustion of landfill gases. The flare system must be of
More information1470 SERIES HOT AIR GAS BURNER
1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light
More information1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER
CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics
More information1466 SERIES COLD AIR GAS/OIL BURNER
CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES
More informationM/SERIES. Installation, Operation, Service, and Parts Manual
M/SERIES Installation, Operation, Service, and Parts Manual! WARNING DANGER ONLY FACTORY AUTHORIZED BURNER SERVICE PERSONNEL SHOULD START UP, ADJUST, OR SER- VICE THIS EQUIPMENT IC-993 09/10 M SERIES
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000
More information2.0 Burner Operating Parameters and Requirements
ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical
More informationModel CBEX Elite HP
Model CBEX Elite 100-800 HP TABLE OF CONTENTS FEATURES AND BENEFITS.....................................................3 PRODUCT OFFERING.........................................................3 DIMENSIONS
More informationG861 Series Integrated Function. Direct Spark Ignition Control
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:
More informationPower Flame Incorporated
Power Flame Incorporated DC-4 SEQUENCE OVERFIRE DRAFT CONTROL SYSTEM OPERATING AND MAINTENANCE MANUAL THE POWER TO MANAGE ENERGY 2001 South 21 st Street, Parsons, Kansas 67357 Telephone 620-421-0480, Fax
More informationGEMINI GAS CONTROL PRODUCT INFORMATION
GEMINI GAS CONTROL PRODUCT INFORMATION The Gemini (6G) combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition
More informationInfo 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes
Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &
More informationSkotch Trifecta Oil Valve System
Skotch Trifecta Oil Valve System A compact high-performance valve system for firing and purging oil-fired burners and igniters. Revision 0 Need a reliable, cost-effective solution for firing and purging
More informationLecture 27: Principles of Burner Design
Lecture 27: Principles of Burner Design Contents: How does combustion occur? What is a burner? Mixing of air and gaseous fuel Characteristic features of jet Behavior of free (unconfined) and confined jet
More informationAggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS. For Hot Mix Asphalt Facilities
Aggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS For Hot Mix Asphalt Facilities ASTEC COMPANY PROFILE Astec, Inc. designs, manufactures and markets continuous and batch-process hot-mix asphalt
More informationDesign and Application Details
Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are
More informationICEMINI & Vertical MTI Units
ICEMINI & Vertical MTI Units ICEMINI Units......K-1 ICEMINI-8MPN (Dimension Information)....... K-2 ICEMINI-8MPN (Horizontal Small)....... K-3 ICEMINI-8MPN (Vertical Small)........ K-4 ICEMINI-8MPN (Vertical
More information36C and 36D Gas Control Product Information
6C and 6D Gas Control Product Information The 6C and 6D combination gas control valves are compact multifunction controls designed to meet requirements for use with Standing Pilot systems and all types
More informationXL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration
XL/LNXL SERIES Installation, Operation, and Service Manual for Vertical Configuration! WARNING DANGER ONLY FACTORY AUTHORIZED BURNER SERVICE PERSONNEL SHOULD START UP, ADJUST, OR SERVICE THIS EQUIPMENT
More informationG821L/G822L Series Integrated Function Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G821L/G822L Issue Date 1199 G821L/G822L Series Integrated Function Direct Spark Ignition Controls
More informationDATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL
DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL DATA SHEET Model: TG3 Revision Date: September 2015 Output: 200 2950 kw Revision Number: DS.TG3.19 All models approved to current British and
More informationinfo NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners
info Information on Ultra ow O x gas burners O x emissions
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationPower Flame Incorporated
Power Flame Incorporated CX BURNER PARTS LIST THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 620-421-0480, Fax 620-421-0948 Web Site: www.powerflame.com E-Mail: CSD@powerflame.com
More informationBurner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110
NOTES: Burner Capacity Information, BBC 111/211 NATURAL GAS, AMBIENT COMBUSTION AIR OPERATION, LOW PRESSURE ATOMIZATION Capacity (at 1% Excess Air) Gas Inlet Pressure Flame Length (at 1% Excess Air) Flame
More information100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE
100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up
More informationPower Flame Incorporated
Power Flame Incorporated VARICAM ADJUSTMENT INSTRUCTIONS THE POWER TO MANAGE ENERGY 2001 South 21 st Street, Parsons, Kansas 67357 Telephone 620-421-0480, Fax 620-421-0948 Web Site: www.powerflame.com
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationFirst Correlating Revision No. 1-NFPA [ Section No ]
First Correlating Revision No. 1-NFPA 85-2013 [ Section No. 3.3.52.1 ] 3.3.52.1 Booster Fan. A device fan used to assist in the supply of air to, or the removal of flue gas products from, the combustion
More informationDATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL
DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL DATA SHEET Model: TG4 Revision Date: September 2015 Output: 600 6500 kw Revision Number: DS.TG4.16 All models approved to current British and
More informationRatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750
Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact
More informationRatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000
Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.
More informationBOILER RATINGS. Net Ratings Oil Gas
POWER BURNER Series TC II Large Commercial s -, Assembled Block or Individual Sections Forced Draft ing Power s - Oil, Gas, Gas/Oil or Hot s Optional Tankless Coils Increased Efficiencies Oil Input GPH
More informationBBC Multi-fuel Combination Beta Burner
BBC Multi-fuel Combination Beta Burner BBC-1 Edition 11-08 Designed for low pressure air operation Rugged heavy gauge steel construction Converging tile provides higher velocity flames for higher convective
More informationC C A. Combustion Components Associates, Inc.
C C A Combustion Components Associates, Inc. www.cca-inc.net About CCA CCA is a global provider of combustion control technologies to reduce NOx, particulate matter (PM), unburned carbon and CO emissions
More informationPilot Capacities/Specifications
s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will
More informationEclipse RatioAir Burners
Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged
More informationTriOx Triple Air Staged Ultra Low NOx Burner
Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent
More informationZEECO BURNER DIVISION
ZEECO BURNER DIVISION Enhanced Jet Flat Flame Burners GLSF Series 22151 EAST 91ST STREET BROKEN ARROW OK 74014 USA +1-918-258-8551 SALES@ZEECO.COM ZEECO.COM INTRODUCTION: This document discusses the advantages
More informationModel CBLE Boilers HP
Boilers 125-800HP CONTENTS FEATURES AND BENEFITS.....................................................4 True Boiler/Burner/Low NOx Package................................................4 PRODUCT OFFERING.........................................................4
More informationNorth American 4485 Tempest SE
Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable
More informationMethods of combustion in combustion chambers that are specially adapted for generation of combustion products of high pressure or high velocity.
F23R GENERATING COMBUSTION PRODUCTS OF HIGH PRESSURE OR HIGH VELOCITY, e.g. GAS-TURBINE COMBUSTION CHAMBERS (fluidised bed combustion apparatus specially adapted for operation at superatmospheric pressures
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationWeishaupt Low NOx Solutions for Boiler Applications
Weishaupt Low NOx Solutions for Boiler Applications Presentation by Greg Meyer Ottawa, 2003 Content Weishaupt Company and Products Weishaupt Low NOx Solutions Applications 1 Max Weishaupt GmbH Administration
More informationRESIDENTIAL BOILER 95% HIGH EFFICIENCY COMMERCIAL BOILER 93% HIGH EFFICIENCY
RESIDENTIAL BOILER 95% HIGH EFFICIENCY WARRANTY: 12 YEARS LIMITED AGAINST LEAKS; PARTS = 1 YEAR STANDARD EQUIPMENT: PLASTIC TEE & COUPLING W/SCREENS, 30 PSI RELIEF VALVE, 0-60 PSI PRESSURE AND TEMPERATURE
More informationClean Burning Technology
The MTC Clean and Superclean burners were developed to provide the Well testing market with a compact, lightweight and practical clean up and separated oil burning solution with a complete combustion system
More information