Assembly Numbers Style A, B & C LINOFLAME Burners
|
|
- Estella Dennis
- 5 years ago
- Views:
Transcription
1 Premix-type Line Burners Page 00-A/P-1 Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with cast iron ignition rails L INOFLAME Burner Section Description straight section (Code) S tyle "A" S tyle "B" Style "C" LA-(*)-36 LA-(*)-72 LB-(*)-24 LB-(*)-36 LB-(*)-72 LB-(*)-96 LC-(*)-24 C onfigured Item [ 2] LA36 LA72 LB24 LB36 LB72 LB96 LC24 straight section with # 6" straight section 6" straight section with # 8" straight section 8" straight section with # (-3) (-6) (-8) Size and number of drilled ports for all LINOFLAME Burner sections must be specified on order " straight section (-9) 1 straight section 1 straight section 1 straight section bossed side inlet with # (1-1/ NPT) 1 straight section (1-1/ NPT) bossed side inlet with # 1 straight section bossed back inlet (1-1/ NPT) 1 straight section (1-1/ NPT) bossed back inlet with # straight section bossed back inlet (1" NPT) straight section (1" NPT) bossed back inlet with # 1 tee section side inlet 1 tee section side inlet with # 1 tee section back inlet 1 tee section back inlet with # (-) (-S) (-B) (-3B) (-TS) (-TB) [1] [ 1] Style C LINOFLAME section requires 10mm spark ignitor #18110 [ 2] T o order line burner arrangements, o rder the appropriate configured item number. To order burner sections loose, order individual burner section assembly numbers. 4/11
2 Page 00-A/P-2 Premix-type Line Burners Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with cast iron ignition rails L INOFLAME Burner Section Description Bottom & Side Inlet Flange for (-TS) & (-TB) sections Inlet Flange (Code) S tyle "A" S tyle "B" Style "C" LA36 LA72 LB24 LB36 LB72 LB96 LC24 1-1/4" NPT 1-1/4" -LFC / NPT 1-1/ -LFE NPT 2 " -LFE cross ignition section (-TX) 3 " elbow section (-E3) 6 " elbow section (-E6) midget section L M-3-72 [ 1] / NPT L FB- 1-1/ " NPT L FB / NPT L FB- 2-1/ " NPT L FB B to C reducing section LBC-3 Division plate (plain) plate (flame rod) plate cross ignition Universal plate support bracket (order in pairs) rod holder LEP LEP-FR LXEP LDP (1) U SB (CS) / (SS) 2LFBR rod L= 7-1/8" (with cover) [1] Suggested drilling for LM-3-72 is #44 mains and #44 ignitors (maximum ignitor port drill size is #44) (1) Size and number of drilled ports for all LINOFLAME Burner sections must be specified on order
3 Premix-type Line Burners Page 00-A/P-3 Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with alloy ignition rails LINOFLAME Burner Description straight section Section (Code) S tyle "A" S tyle "B" Style "C" LAA-(*)-36 LAA-(*)-72 LBA-(*)-24 LBA-(*)-36 LBA-(*)-72 LBA-(*)-96 LCA-(*)-24 C onfigured Item No. [ 1] LAA36 LAA72 LBA24 LBA36 LBA72 LBA96 LCA24 straight section with # 6" straight section 6" straight section with # 8" straight section 8" straight section with # (-3) (-6) (-8) " straight section (-9) 1 straight section 1 straight section with # 1 straight section (1-1/ NPT) bossed side inlet 1 straight section (1-1/ NPT) bossed side inlet with # 1 straight section (1-1/ NPT) bossed back inlet 1 straight section (1-1/ NPT) bossed back inlet with # straight section (1" NPT) bossed back inlet straight section (1" NPT) bossed back inlet with # 1 tee section side inlet 1 tee section side inlet with # 1 tee section back inlet 1 tee section back inlet with # (-) (-S) (-B) (-3B) (-TS) (-TB) [ 1] To order line burner arrangements, o rder the appropriate configured item number. To order burner sections loose, order individual burner section assembly numbers Size and number of drilled ports for all LINOFLAME Burner sections must be specified on order 4/11
4 Page 00-A/P-4 Premix-type Line Burners Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with alloy ignition rails L INOFLAME Burner Section Description Bottom & Side Inlet Flange Set for (-TS) & (-TB) sections Inlet Flange Set (Code) S tyle "A" S tyle "B" Style "C" LAA36 LAA72 LBA24 LBA36 LBA72 LBA96 LCA24 1-1/ NPT L FB- 1-1/ " NPT L FB / NPT L FB- 2-1/ " NPT L FB /4" NPT 1-1/4" -LFC / NPT 1-1/ -LFE NPT 2 " -LFE cross ignition section (-TX) 3 " elbow section (-E3) 6 " elbow section (-E6) Division plate (plain) plate (flame rod) plate cross ignition plate Universal support bracket (order in pairs) rod holder LEP LEP-FR LXAEP LDP (1) USB LFBR Pilot mounting bracket (1) rod L= 7-1/8" (unsealed) or (sealed) Size and number of drilled ports for all LINOFLAME Burner sections must be specified on order (1) 26634
5 Premix-type Line Burners Page 00-A/P-5 Style A, B & C LINOFLAME Burners Spare Parts -mounted LINOPAK Pilots f or Style A, B & C LINOFLAME Burners Pilot Assembly Pilot Description Inert air LINOPAK pilot Fresh air LINOPAK pilot Fresh air LINOPAK pilot (w/vane) Inert air LINOPAK pilot (w/vane) Pressure type LINOPAK pilot Pressure type LINOPAK pilot (w/vane) Pilot Assembly Includes: Pilot Mixer Gas Adjustable Orifice Cock Miscellaneous Optional Accessories Spark Ignitor 18mm spark ignitor (R) 10mm spark ignitor (R) Electrode cover for flame rod or spark ignitor (A) Side-mounted pilots f or Style A, B & C LINOFLAME Burners Pilot Assembly Pilot Description Fresh air type L INOFLAME pilot Fresh air type (with vane) Recirculating (with vane) type Pressure type pilot (with vane) Open port venturi pilot Pilot Assembly Includes: Pilot Mixer Gas Adjustable Orifice Cock Spark Ignitor Miscellaneous Optional Accessories S tyle B Only ( threaded flanges) 1 (1.5" NPT bossed side inlet) straight section 1 (1.5" NPT bossed side inlet) straight section w/ SI 1 (1.5" NPT bossed back inlet) straight section 1 (1.5" NPT bossed back inlet) straight section w/ SI (1" NPT bossed back inlet) straight section (1" NPT bossed back inlet) straight section w/ SI /11
6 Page 00-A/P-6 Premix-type Line Burners V F LINOFLAME Burner Sections Item Burner Sections VF LINOFLAME Burners C onfigured Item [ 1] VF H Section Descriptio n VF V FH LINOFLAME FL LINOFLAME Assembly L V Assembly 1 straight V FH V FL Back Inlet Feed Sections 1 x 1 back inlet cross V FH-XB (24) V FL-XB (15) (each requires an inlet flange from below) 1 back inlet straight V FH-B (17) V FL-B ANS Back Inlet Flange Options Back Inlet Flange Option Cap Sets Plate Sets ANS Inlet Flange Options Inlet Flange Options For (B) back inlet sections For (XB) back inlet cross sections For (B) back inlet sections For (XB) back inlet sections cap set-plain cap set with provision for flame #18117 flame rod closure set spark ignitor) NPT V FL-2BF (1) NPT V FH-3BF NPT V FH-3XF V FL-3XF " NPT V FH-4XF VFL-2BF VFH-3BF VFH-3XF VFL-3XF " VFH-4XF rod (order with spark ignitor (includes #18110 High recirculation end plate (use with end cap set or end inlet flange set) Expansion end plate set (includes end closures with necessary expansion joint fasteners) inlet flange set inlet flange set w/provision for flame rod (order #8117 flame rod flange set w/spark ignitor (includes #23739 spark ignitor) inlet flange set inlet flange set w/provision for flame rod (order #18117 flame rod inlet flange set w/spark ignitor (includes #23739 spark ignitor) V FH-EC V FL-EC V FH-EC-FR V FL-EC-FR V FH-EC-SI V FL-EC-SI VFH-HREP VFL-HREP 250 V FH-XEP V FL-XEP / NPT V FL-1-1/2-EF NPT V FH-2-EF NPT V FH-2EF-FR NPT V FH-2EF-SI straight V FH V FL " straight V FH V FL " elbow V FL-L x 6" tee V FH (16) V FL-T x 1 cross V FH-X (20) V FL-X (15) 1-1/ VFL- 1-1/2 -EF VFH-2-EF VFH-2EF-FR VFH-2EF-SI [ 1] T o order line burner arrangements, o rder the appropriate configured item number. To order loose items, order individual assembly numbers. [2] A sealed (cannot be disassembled) version of the flame rod, part number , can also be chosen.
7 Premix-type Line Burners Page 00-A/P-7 VF LINOFLAME Burners E nd-mounted LINOPAK Pilots for "VF" LINOFLAME Burners Available Natural Gas Pressures Low Gas Pressures (4-7" wc) High Gas Pressures (1-2 PSIG) S election Parameters: "VFH" Type of INOFLAME Pilot Mixer Venturi-type Pressure-type (requires 4-16 osi combustion air) Venturi-type Pressure-type (requires 4-16 osi combustion air) Safeguard Rod UV Scanner Rod L Burner LINOPAK Pilot VFH-LO-V-FR VFH-LO-P-UV VFH-LO-P-FR "VFL" L INOFLAME Burner LINOPAK Pilot VFL-LO-V-FR VFL-LO-P-UV VFL-LO-P-FR Pilot Mixer UV Scanner Rod UV Scanner Rod Fasteners for flanges ordered loose Configured Item Description Back inlet flange for (B) back inlet section VFH-HI-V-FR VFH-HI-P-UV VFH-HI-P-FR NPT VFL-HI-V-FR VFL-HI-P-UV VFL-HI-P-FR Part Pilot Assembly Includes: Adjustable Gas Orifice VF Qty. H Part Qty. Part 18mm Spark Ignitor VF Qty. L Part NPT NPT Qty. Back inlet flange for (XB) back inlet cross section inlet flange set NPT " NPT 4" / NPT 1-1/ NPT Miscellaneous Accessories and/or Replacement Parts rod (L = 4.5") Spark ignitor Universal Support Bracket (USB) (normally furnished in pairs) 10mm mm mm (CS) (SS) Rubber cover /11
8 Page 00-A/P-8 Premix-type Line Burners INFRAWAVE Burners I NFRAWAVE Burner Sections Section Type 6" straight sections (I.S.O. assemblies) 1 straight sections (I.S.O. assemblies) Plain N ote: All INFRAWAV E Burner sections use standard (metric) fasteners C onfigured Item [ 1] INFRA SG Description With pilot, includes side-mounted pressure pilot #25906 which includes #11680 pilot mixer, #18110 spark ignitor, #38579 adjustable pilot gas orifice, with provision for mounting a UV scanner With SI and FR, includes side-mounted #23739 spark ignitor, opposite provision for mounting a flame rod (order #18117 flame rod, if used, With SI, of INFRA DG " SG" Single Grid "DG" Double Grid 6 S SG (16) 6 S DG (20) 6 SP SG 6 SP DG (22) 6 SSF DG (21) i ncludes side-mounted #23739 spark ignitor 6 SS SG (16) 6 SS DG (20) With FR-SCAN, includes provision for side-mounting a UV scanner or flame rod (order #18117 flame rod, if used, Plain With pilot, includes side-mounted pressure pilot #25906 which includes #11680 pilot mixer, #18110 spark ignitor, #38579 adjustable pilot gas orifice, with provision for mounting a UV scanner With SI and FR, includes side-mounted #23739 spark ignitor, opposite provision for mounting a flame rod (order #18117 flame rod, if used, With SI, of 6 SFU SG (16) 6 SFU DG (20) S SG (32) S DG (40) SP SG (30) SP DG (37) SSF SG (32) SSF DG (40) i ncludes side-mounted #23739 spark ignitor SS SG (30) SS DG (37) With FR-SCAN, includes provision for side-mounting a UV scanner or flame rod (order #18117 flame rod, if used, [ 1] T o order burner arrangements, order the appropriate configured item number. [2] A sealed (cannot be disassembled) version of the flame rod, part number , can also be chosen. SFU SG (32) SFU DG (40) Segment Choice Detail - INFRAWAVE Burner sections BAFFLE GRID Segment Name Segment Description Choice of baffle grid Segment Choices (DEFAULT is shaded) HIGH_PROF Segment Choice Description High profile grid L OW_PROF Low profile grid (standard) GRID CLAMP Choice of material for grid clamp SS STD Stainless steel clamp material Standard clamp material BODY GASKET Choice of body gasket NO YES Do not include with order Include with order MAX AIRSTREAM TEMP (F) Choice of maximum airstream temperature F max airstream temperature F max airstream temperature
9 Premix-type Line Burners Page 00-A/P-9 I NFRAWAVE Burner Sections Section Type 6" bottom inlet sections (I.S.O. assemblies) NOTE: Select optional inlet flange set separately from listing on following page 1 bottom inlet sections (I.S.O. assemblies) NOTE: Select optional inlet flange set separately from listing on following page 1 side inlet sections (I.S.O. assemblies) NOTE: Select optional inlet flange set separately from listing on following page Plain INFRAWAVE Burners N ote: All INFRAWAV E Burner sections use standard (metric) fasteners C onfigured Item [ 1] INFRA SG Descriptio n With pilot, includes side-mounted pressure pilot, #25906 which includes #11680 pilot mixer, #18110 spark ignitor, #38579 adjustable pilot gas orifice, with provision for mounting a UV scanner W ith SI and FR, includes side-mounted #23739 spark ignitor, opposite of provision for mounting a flame rod (order #18117 flame rod, if used, With SI, INFRA DG " SG" Single Grid "DG" Double Grid 6 BI SG (15) 6 BI DG (19) 6 BI SP SG (17) 6 BI SP DG (21) 6 BI SSF DG (19) i ncludes side-mounted #23739 spark ignitor 6 BI SS SG (15) 6 BI SS DG (19) With FR-SCAN, includes provision for side-mounting of scanner or flame rod (order #18117 flame rod, if used, Plain a UV With pilot, includes side-mounted pressure pilot, #25906 which includes #11680 pilot mixer, #18110 spark ignitor, #38579 adjustable pilot gas orifice, with provision for mounting a UV scanner W ith SI and FR, includes side-mounted #23739 spark ignitor, opposite of provision for mounting a flame rod (order #18117 flame rod, if used, With SI, 6 BI SFU SG (15) 6 BI SFU DG (19) BI SG (28) BI DG (36) BI SP SG (31) BI SP DG (38) BI SSF SG (29) BI SSF DG (37) i ncludes side-mounted #23739 spark ignitor BI SS SG (28) BI SS DG (36) With FR-SCAN, includes provision for side-mounting of a UV scanner or flame rod (order #18117 flame rod, if used, Plain With pilot, includes side-mounted pressure pilot #25906 which includes #11680 pilot mixer, #18110 spark ignitor, # adjustable pilot gas orifice, with provision for mounting a UV scanner W ith SI and FR, includes side-mounted #23739 spark ignitor, opposite of provision for mounting a flame rod (order #18117 flame rod, if used, With SI, BI SFU SG (29) BI SFU DG (36) SI SG (28) SI DG (35) SI SP SG (30) SI SP DG (38) SI SSF SG (29) SI SSF DG (36) i ncludes side-mounted #23739 spark ignitor SI SS SG (28) SI SS DG (36) With FR-SCAN, includes provision for side-mounting a UV scanner or flame rod (order #18117 flame rod, if used, SI SFU SG (29) [ 1] T o order burner arrangements, order the appropriate configured item number. [2] A sealed (cannot be disassembled) version of the flame rod, part number , can also be chosen. SI SFU DG (36) 4/11
10 Page 00-A/P-10 Premix-type Line Burners INFRAWAVE Burners I NFRAWAVE Burner Plate Sets, Accessory Options and Spare Parts Mounted Pilot Assembly NOTE: Select an end plate set from below to close off the end of the burner assembly Bottom & Side Inlet Flange Sets Bottom & Side Flanges Inlet Flange Inlet Sets Inlet Flanges Closure Sets Miscellaneous Accessory Options and Spare Parts Description mounted pressure pilot and mounting bracket, includes pressure pilot #24922 which includes #11680 pilot mixer, # spark ignitor, #38579 adjustable pilot gas orifice with provision to mount a flame rod (order #18117 flame rod, if used, separately) [1] INFRA SG INFRA DG " SG" single grid "DG" double grid " NPT ( ANS) " NPT ( ANS) " NPT ( ANS) " NPT ( ANS) plate set - plate set - e nd closur e b ottom and side closur e F lame rod ( L - 7-1/8") (A/R) (unsealed) or (sealed) S park Ignitor (R) E lectrode protective cover (A/R) for flame rod or spark ignitor U niversal support bracket (A) USB normally furnished in pairs 10mm mm mm zinc plated, good up to 750 F stainless steel, good up to 1600 F F lame rod cooling tee ( A) R efractory baffle grid (R) Manifold gasket S tandard (Low Prof); (High Prof) D rilled for pilot (Low Prof); (High Prof) D rilled for ignitor (Low Prof); (High Prof) ( R) for field assembly M anifold gaske t, 6" body (R) M anifold gaske t, 1 body (R) # 310SS grid clamp ( R) # 310SS deflector rail ( R) D eflector rail, cross ignition ( R) Maximum airstream temperature: 450 F (rubber boot limit); 600 F (burner limit if up-fired, 400 F if down-fired) [1] A sealed (cannot be disassembled) version of the flame rod, part number , can also be chosen.
Assembly Numbers. Approximate net ship weight (in pounds) shown in parentheses
Page 5700-A/P-1 Burner Sections Back Inlet Feed Sections (each requires inlet flange from Page 5700-A/P-2) C OMBUSTIFUME Line Burners Material Specifications > w/#310 SS mixing plates w/ Hastelloy X mixing
More informationPilot Capacities/Specifications
s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will
More informationDesign and Application Details
LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog
More informationPerformance Selection Data
Series "NP" & "RG" AIRFLO Burners Page 5505 Performance Selection Data Operation in shaded area requires special considerations Optimum Design Area Operation in shaded area requires special considerations
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationCrest Heating Boilers FBN(L)
Replacement Parts List S & SERVICE DEMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 2500-6000 69 67 59 62 79 18 26 66 76
More informationAssembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)
Series 67 TUBE-O-FLAME Burners Page 2200-A/P-1 For these products, please order per the following product numbers: (configured products are those with alphanumeric text) Size Packaged Burner 6-08 608 TOF
More informationDesign and Application Details
Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are
More informationCrest Heating Boilers FBN(L)
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65
More informationGAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign
3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationAPX Nozzle-mix line burner
Duct urners - PX urners 1 E-i-03/16 PX Nozzle-mix line burner Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminum extrusion
More informationSpecifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry
4-22.4-4 Specifications of LVDT/HC-pilot burner Typical burner data 15 C 21 % O 2 combustion air 50 % humidity natural gas with 10.9 kwh/m³(st) HHV - sg = 0.6 [1] Stated pressures are indicative - actual
More informationAPX Nozzle-mix line burner
Nozzle-mix line burner TECHNICL CTLOG Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminum extrusion body design Cooler
More informationEclipse RatioAir Burners
Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire
More informationAPX Nozzle-mix line burner
Nozzle-mix line burner TECHNICL CTLOG Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminum extrusion body design Cooler
More informationPREMIX TUNNEL BURNERS
FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,
More informationStart-up Instructions
RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been
More information15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE
Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.
More informationECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH
Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower
More information15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS
Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.
More information36/60/160/260 L Series Gas Ranges
VULCAN L Series Gas Ranges 36/60/160/260 L Series Gas Ranges 34 THRU 41 1 5 51 52 26 42 THRU 49 55-56-57 2-3-4 33 31-32 25 29-30 27 15 PL-53065 14 13 12 28 24 23 22 21 20 19 18 16 17 52 11 10 9 8 7 6 632
More informationF300 Pressure Regulator
F300 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P302 has Internal Relief Valve for Overpressure Protection Ideal for Fix Factor Billing The F300 series pilot operated
More informationLVDT/HC PILOT BURNER. External raw gas pilot burner
4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable
More informationFigure 1-1(d) Tft Installation Kit
TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending
More informationReplacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & 101
More informationSpecifications of OPTIMA SLS Burners
1.1.9-4 Low emperature urners - PIM L pecifications of PIM L urners ypical burner data Fuel: natural gas at 60 F with 1000 tu/ft 3 (st) HH - sg = 0.6 (1) ombustion air: 60 F - 21% 2-50% humidity - sg =
More informationGROUP E EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 ITEM PART# QTY. DESCRIPTION
EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 GROUP E ITEM PART# QTY. DESCRIPTION 1 026915 2 NIPPLE CLOSE 3/4 X 1.375 2 075580 1 FLANGE FUEL INLET 3 0F6390C 1 REGULATOR ASSY 2.4L (25KW) 0F6390B
More information2.0 Burner Operating Parameters and Requirements
ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical
More informationQ SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER
Models Q90-25 Q90-50 Q90-5 Q90-200 Q90 25-200 SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER REPAIR PARTS, OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When
More informationMULTIFIRE. High temperature dual fuel burner
MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,
More informationThe Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor
OPERATIONS MANUAL The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor The CSA approved alternative ignition system delivering safety, reliability and versatility. KEY FEATURES Unique
More informationIgniter, BMS & Valve Parts Directory Contact Us Toll Free:
Igniter, BMS & Valve Parts Directory Phone: (03) 32-9 Email: sales@combustex.com Web: www.combustex.com Combustex is ready to provide you with the spare parts you need to keep your Pilot Pro Igniters,
More informationNorth American 4575 HiRAM
Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace
More informationAll repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change
4 Parts To Your Door Repair Parts Trade Price List (R-18) Effective June 1, 2018 Description Quantity Required 1 Ignition Electrode KIT includes Gasket, Hardware, and Cable 1 54835 $75 2 Sensor Electrode
More informationIHR Series With Standard Oven ITEM NO DESCRIPTION PART # 36" 1 Top Grate Cast Iron 12" X 28" - (Old Style) 1187 N/A *** 12" Top Grate 12 x 13 1/4
1 Top Grate Cast Iron 12" X 28" - (Old Style) 1187 N/A *** 12" Top Grate 12 x 13 1/4 (Front) Open Burner 35334 3 *** 12" Top Grate 12 x 13 1/4 (Rear) Open Burner 35335 3 2 Top Grate Cast Iron 18" X 28"
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationPARTS LIST GAS TILTING SKILLETS MODELS: ACGTS-30 ACGTS-40
PARTS LIST GAS TILTING SKILLETS MODELS: ACGTS-30 ACGTS-40 ACCUTEMP PRODUCTS, INC. 8415 North Clinton Park Dr. Fort Wayne, IN 46825 800 210-5907 Office 260 493-0415 Fax www.accutemp.net PART 10006R13 1
More information94407 Horizontal Inline Deflagration Flame Arrester
94407 The Shand & Jurs 94407 Horizontal Inline Deflagration Flame Arrester is designed to provide a positive flame stop in horizontal gas piping systems containing flammable vapors having a low flash point.
More informationLow emissions, high performance natural gas burners
-.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner
More informationREPLACEMENT PARTS LIST. M1 Series
REPLACEMENT PARTS LIST M Series Model MG(*) Item Description MGH MG(B,C,D) 056 070 077 090 056 070 077 090 Louvered Door (White) 9007 9007 9007 9007 9007 9007 9007 9007 Coil Door (White) 9009 9009 9009
More information47 SERIES GAS FRYERS PARTS LIST
8. Accessories 80-00 Basket, Twin 80-008 Basket Hanger (for Non-Basket Lift Fryers) 80-0 Basket Support Rack 8- Drain Extension Pipe (for use on units w/o built-in filtration systems) 80-009 Frypot Cleanout
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure
More informationLow Temperature Burners - STICKTITE and PILOTPAK Nozzles
Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean
More informationLB601B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools
COMPRESSORS CB-5E-051 2011/06 LB601B PARTS LIST Serial # ID# Gasket Set, Repair Kits and Special Tools Gasket Set Buna-N & Aluminum 794099 Top End Repair Kit 794237 Includes Piston Rings & Expanders, Packing
More informationCOMPRESSORS 09/97 CB-5C-050. Suggested Spare Parts for LB601 and LB601A Compressors: Qty./ Unit
09/97 CB-5C-050 Suggested Spare Parts for LB601 and LB601A Compressors: Part # Description Qty./ Unit Comm. Qty. 794099 Gasket Set - Buna-N, Aluminum T 1 1 1 794259 Suction Valve Sub-Assembly T 2 2 794279
More informationReplacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38
More informationFD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS
SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF
More informationCrest Heating Boilers FBN(L)
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 1500-5000 67 65 57 60 77 18
More informationLVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1
Gas Limiting Orifice Valve Features Precision machined valve flow piston Rugged cast iron body Replaceable cartridge assembly for LVG 55-5 Straight through valve design; right angle valve option Pressure
More informationQ SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER
Models Q90-25 Q90-50 Q90-75 Q90-200 Q90 25-200 SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER REPAIR PARTS, OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When
More informationGAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]
GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER (25-200 MBH) REPAIR PARTS MANUAL P/N 24000523, Rev..2 [02/06] TABLE OF CONTENTS I. Circulator Pumps (Optional)...2 II. Burner Assembly...3 III. Boiler
More informationRatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750
Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact
More informationCrest Heating Boilers FBN(L)
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 1500-5000 67 65 57 60 77 18
More information94406 Vertical Inline Deflagration Flame Arrester. Features
94406 The Shand & Jurs 94406 Vertical Inline Deflagration Flame Arresters are designed to provide a positive flame stop on low pressure tanks or piping systems containing flammable liquids or solvents
More informationRatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000
Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
-.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an
More informationEclipse RatioAir Burners
Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged
More information2500/2700 Series Gas Convection Oven
MARKET FORGE 2500/2700 Series Gas Convection Oven 2500/2700 Series Gas Convection Oven 2500 2700 2592 2792 Control Panel Assembly 1 99-4209 Control Panel Assembly Complete (Excluding Thermostat) 2 10-6307
More informationInfo 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes
Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &
More information1466 SERIES COLD AIR GAS/OIL BURNER
CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES
More informationIR 2000 Series Medium Duty Range w/standard Oven ITEM NO DESCRIPTION PART # 24" 36" 48" 60" 72" Griddle Plate Assembly 24"
1 Griddle Plate Assembly 12" 20006 1 1 1 1 1 Griddle Plate Assembly 24" 20007 1 1 1 1 1 Griddle Plate Assembly 36" 20008 1 1 1 1 Griddle Plate Assembly 48" 20009 1 1 1 Griddle Plate Assembly 60" 20010
More information95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER REPAIR PARTS MANUAL. P/N , Rev. C [09/08]
9M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER REPAIR PARTS MANUAL P/N 240006107, Rev. C [09/08] TABLE OF CONTENTS Burner/Igniter Assembly... 4 Exhaust Tee/Condensate Trap Assembly... Boiler
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural
More informationProduct Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures
More informationField proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility
-.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER
More information1070 SERIES ULTRA LOW NO X
CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationSpecifications of MAXON VALUPAK burners for 50 Hz operation
1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size
More informationUB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler
UB9M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Repair Parts Manual Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number
More information97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel
97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic
More informationThe Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor
OPERATIONS MANUAL The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor KEY FEATURES Strong, Reliable Ignition & Pilot Flame Rapid Flame Response LED Flame Status Indicator Fully
More information1470 SERIES HOT AIR GAS BURNER
1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light
More informationToll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com MODEL: MCO-GS/GD-10 MU - CE UNITS Oven Manufactured Up To May 29, 2008 DESCRIPTION
More informationOPEN FIRED STARJET BASIC UNIT SJ075 SJ260
OPEN FIRED STARJET BASIC UNIT SJ075 SJ260 PARTS LIST Y4135 No. Description SJ075 SJ150 SJ200 SJ260 1 Burner, Basic 46965 70301 70319 70305 a Spin Vane Adjustment 46982x001 46982x001 46353x001 46353x001
More informationF200 Pilot Operated Pressure Regulator
F00 Pilot Operated Pressure Regulator External or Internal Pressure Registration Minimize Sudden ownstream Load Change Ideal for Fix Factor Billing Quick Response Time / High ccuracy The F00 series is
More informationS1 SERIES TECHNICAL DATA INFORMATION PACKET
S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical
More informationOPN DESCRIPTION QTY B-160 See next page for drawing of B-160 Blower -46-
-45- Models B-1501 B-160 OPN DESCRIPTION QTY A 002016 3/8" Jam Nut 8 B 010008 Support Rod Bracket 2 C 002017 3/8" Hex Lock Nut 2 D 100475 Lid Support Rod 2 E 010009 Lid Lift Bushings 4 F 010005 Drive-In
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data
More informationKINEMAX. Medium velocity gas or oil burners
KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,
More informationControls and Accessories Part Number Controls and Accessories Part Number
Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION
More informationLB361B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools
COMPRESSORS CB-5E-031 2011/06 LB361B PARTS LIST Serial # ID# Gasket Set, Repair Kits and Special Tools Gasket Set Buna-N & Aluminum 793099 Top End Repair Kit 793229 Includes Piston Rings & Expanders, Packing
More informationJANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS
JANDY HEATERS Heaters H-58 A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS E-Z FIND CHART MARK V XE XE SERIES I SERIES I MILLIVOLT MILLIVOLT ELECTRONIC MILLIVOLT ELECTRONIC DM, DR EG ES, EC EPG EPS,
More informationBLOC U A-12G BLOC U C-12G
3.3- INJECTOR BLOCKS AND ORIFICES 3.3.1- INJECTOR BLOCKS WITHOUT IGNITION AND WITHOUT FLAME SAFETY BLOC U-0-000-000-00-A-12G...3.3.1.1 BLOC U-0-000-000-00-C-12G...3.3.1.2 Related sections : Burners...3.2
More informationData /1/07 Eclipse RatioAir Burners Model RA0040
Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet
More informationPROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for
More informationBOILER RATINGS. Net Ratings Oil Gas
POWER BURNER Series TC II Large Commercial s -, Assembled Block or Individual Sections Forced Draft ing Power s - Oil, Gas, Gas/Oil or Hot s Optional Tankless Coils Increased Efficiencies Oil Input GPH
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationM SERIES TECHNICAL DATA INFORMATION PACKET
M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical
More information2013 MASTER PARTS LIST Effective: 2013-May-01 to 2014-Apr-30
2013 MASTER PARTS LIST Effective: 2013-May-01 to 2014-Apr-30 Table of Contents Parts Breakout 1.0 Trinity Lx150-800....................................... 1 Residential Lx150-400 Commercial Lx500-800 2.0
More informationNorth American 4485 Tempest SE
Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable
More informationSAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY
PROVIDES HIGH QUALITY OVERPRESSURE PROTECTION FOR AIR, GAS, LIQUID & STEAM IN SINGLE STANDARDIZED DESIGN SAFETY relief VALVE DESIGN FEATURES SAFETY VALVE MANUFACTURED IN ACCORDANCE WITH REQUIREMENT OF
More informationBurner Selection Criteria
UNI-RAD Radiant Tube Burners Page 4803 Burner Selection Criteria Combustion Air View Port/Optic Flame Sensor Mount Gas Inlet 3"- 4" Burner Selection The UNI-RAD Burner can be used with various radiant
More informationOT LE 600/900/1200 GAS
OXYTHERM LE Burners Configured Item Number: OT LE for configured item number OT LE ASSEMBLY NUMBER PAGES SERIES FUEL Choice of burner series Choice of fuel 12 1200 Series 6 600 Series 9 900 Series G Gas
More informationReplacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46
More informationUNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M
UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M-02007-01 TABLE OF CONTENTS Product Description... 3 Features and Benefits... 3 Applications... 3 Modes of Operation... 3 Burner Selection
More information1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER
CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics
More informationWafer Silent Check Valves
Applications Liquid Service Metals & Mining Process Industry Water & Waste Water Power Industry Pulp & Paper Chemical Industry Oil & Gas Wafer Silent Check Valves Pressures to 740 PSIG Temperatures to
More informationLinea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN
Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame
More information