HelioProtection Program

Size: px
Start display at page:

Download "HelioProtection Program"

Transcription

1 HelioProtection Program SOLUTIONS guide Photovoltaic Solutions (ISSUE 8) Ferraz Shawmut is Mersen

2 THE COMMITMENT OF MERSEN IN SAFER AND MORE RELIABLE SOLAR PHOTOVOLTAIC INSTALLATIONS In the solar market more especially, Mersen is a driving force in the development of safer and more reliable solar photovoltaic installations. To participate in implementing such installations, Mersen has developed a special program of solutions branded HelioProtection. HelioProtection program is a mix of: d edication all the solutions have been applications. Innovation the solutions in this program are all on the technological edge. e xpertise this program is supported in the marketplace by a team of Mersen s experts for helping the customer to select and apply the proper solution. HelioProtection is a brand of Mersen, the new name of Ferraz Shawmut. 2

3 GOING EVEN FURTHER TOGETHER To support all those we work with - developers, designers, engineering consultants, purchasers, quality managers, and listing agencies - in their efforts to specify, design, build, test and run solar power systems, Mersen has invested in the necessary resources: complex and arduous projects and get involved in co-design or co-development initiatives; a technical support department with attentive engineering staff listening to other professionals and helping them match protection components or solutions to their equipment; a hotline at Two labs dedicated to quality The proof of that quest for continual improvement: a total of more than a million tests in 25 years! Mersen has two test labs: one in Newburyport, Massachusetts, and one in Saint Bonnet de Mure in France. The two are complementary, in terms of the available resources, to be able to offer the widest possible range of a.c. and d.c. tests to UL-CSA and IeC standards. Mersen welcomes customers at both locations to run test campaigns focused on critical points in their own bills of requirements. An innovative PV installation for product test and validation with a total power of 35KW and an exclusive 6 strings of 24 PV modules or 12 strings of 12 PV modules. Newburyport: a specialized d.c. lab - obviously an asset in designing fuses for photovoltaic applications; a low power test lab; fusion tests at 0 to 6000A constant current; simulations of equipment starting up and stopping from 0 to 3000A; a low voltage test bench for surge protective devices; temperature tests, etc. Saint-Bonnet-de-Mure: temperature rise and strength tests on test benches with extra low voltage power supply; short circuit withstand tests (400MVA generator); d.c. tests with large time constants; dielectric tests at industrial frequencies; faraday cage impulse voltage tests; oven climate tests from -45 C to +150 C, plus salt mist; mechanical tests, pressure, vibration, acceleration - and more. Mersen Photovoltaic solutions 3

4 STANDARDIZATION COMPONENTS, SYSTEMS AND INSTALLATIONS Photovoltaic equipement and systems are governed by international general standards. IeC and UL standards provide the rules to apply to implement state-of-the-art PV installations. Besides that international or more local standards relay and complete the general standards. They concern complete systems and installations, components incorporated in the systems and connection to the grid. general Standards IEC Edition 1 Installation and safety requirements for photovoltaic (PV) generators Standards, guidelines, Recommendations PV Installations PV Systems IEC Low Voltage Installations PV Installations. DIN V VDE V Junction boxes for photovoltaic modules. IEC Low voltage switchgear and controlgear assemblies Surge Protective devices (SPds) EN Low voltage surge protective devices Surge protective devices D.C. Part 11: Requirements and tests for SPDs in photovoltaic applications Fuses for Photovoltaic Systems UL 2579 IEC Low voltage fuses Part 6: Supplementary requirements for fuse-links for the protection of solar PV energy systems. Photovoltaic Fuseholders UL enclosed and dead-front Switches for use in Photovoltaic Systems UL 98B PV Power Converters And grid Connection IEC Photovoltaic (PV) systems Characteristics of the utility interface. 4

5 GUARANTEED PROTECTION, FROM THE CELL TO THE GRID The fact that a solar device is both a dc environment and a non interruptible source of current whenever the sun is shining makes things pretty complicated compared to our customary AC world. ensuring the safety of solar power generating facilities is a tricky business, because there are So compliance with standards and recommendations is critical to guaranteeing the safety of people and property. Mersen Photovoltaic solutions 5

6 PV Fire Shunt RESIDENTIAL The PV Fire Shunt expands the HelioProtection program, with a product designed for the residential PV solar market. equipped with a PV system. The technology employed (a shunt that lowers voltage to almost 0V when the handle is pulled) and the product s mechanical characteristics (materials a safer working environment with no electrical hazard. It can shunt up to 3 strings of solar modules using ground level. HP6SH3STR32 Reference F28933 description Weight Packaging Shunt 600VDC 3 strings max. 32A 2.8kg 1 Ratings Ith=32A, (for Iscmax=25.4A) Icm=32A Ue=600VDC Ui=600VDC Uimp=8kV Maximum current per connector 17A Connection of max 3 strings if 1 tracker in the inverter and no string protection High temperature withstand curve ISO834 30min, 842 C Dust and waterproof to IP55 Outdoor mechanical impacts Operating temperature: -40/+90 C 4 MC4 connectors Cover color: beige RAL15 PV Fire Shunt Ith = 32A Ue = 600V

7 Residential DC & AC Combiner Boxes RESIDENTIAL A dedicated product offer for private home and small apartment building PV system from 3 to 5kW. dc combiner box DC combiner boxes are located between the solar modules and the inverter. This provides an optimal connection system for 2 strings of 25A under 600VDC or 20A under 00VDC. The DC combiner boxes include load isolation and surge protection of inputs dc ratings dc surge protection Input connection type Output connection type Protection class HSB2IT20SPZ 2 25A, 600VDC M16, Ø: 4.5-mm M16, Ø: 4.5-mm or Type II, 00VDC HSB2IT20SPX 2 20A, 00VDC MC4 connection M16, Ø: 4.5-mm IP65, IK07 AC combiner box AC combiner boxes are located between the inverter and the meter. This provides an optimal connection and protection for the AC network. The AC combiner boxes include a differential load breaker and an AC surge protection. AC ratings AC surge protection Input connection type Output connection type Protection class HSAC16A230V 16A, 230VAC M20, Ø: 7-13mm M20, Ø: 7-13mm Type II, 230VAC HSAC25A230V 25A, 230VAC M20, Ø: 7-13mm M20, Ø: 7-13mm IP65, IK07 Mersen Photovoltaic solutions 7

8 HelioProtection Fuse gpv HP6M 600VDC RESIDENTIAL the PV modules against the reverse currents. These HP6M fuses, designed for low minimum breaking capacity capabilitiesof 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Minimum Breaking Capacity = 1.35In Maximum Breaking Capacity = ka drawing Max.Operating Voltage = Rated Voltage Rated Current Ref. Packaging 600VDC UL Listed IEC Approved (gpv) 1 HP6M1 L18565J 2 HP6M2 M18566J 3 HP6M3 N18567J 4 HP6M4 Q18569J 5 HP6M5 R18570J 6 HP6M6 S18571J 7 HP6M7 T18572J 8 HP6M8 V18573J HP6M X18575J 12 HP6M12 Y18576J 15 HP6M15 Z18577J 20 HP6M20 A18578J 25 HP6M25 K186J 30 HP6M30 L18611J mm DERATING COEFFICIENT (% OF FUSE RATING) ,5mm Ø mm Fuse holders 0.8 Nb of poles Reference Nb of modules (17.5mm) Packaging Indicator US1HEL D09979K 1 12 No 1 US1IHEL Q09461K 1 12 Yes 1 USGM1HEL P22294K 1 12 No 1 USGM1IHEL N22293K 1 12 Yes AMBIENT TEMPERATURE ( C) electrical Characteristics Rated Voltage (V) Nominal Current (A) 70% AMP RATINg (W) 80% AMP RATINg (W) 0% AMP RATINg (W) HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M HP6M

9 HelioProtection Fuse gpv HPM 00VDC BUILDINGS SOLAR FARMS the reverse currents. These HPM fuses, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Minimum Breaking Capacity = 1.35In Maximum Breaking Capacity = ka drawing Max.Operating Voltage = Rated Voltage Rated Current Ref. Packaging 00VDC UL Listed IEC Approved (gpv) 1 HPM1 B18579J 2 HPM2 C18580J 3 HPM3 D18581J 4 HPM4 E18582J 5 HPM5 F18583J 6 HPM6 G18584J 7 HPM7 H18585J 8 HPM8 J18586J HPM L18588J 12 HPM12 M18589J 15 HPM15 N18590J 20 HPM20 P18591J 25 HPM25 D23825J 30 HPM30 E23826J mm DERATING COEFFICIENT (% OF FUSE RATING) ,5mm Ø mm Fuse holders 0.8 Nb of poles Reference Nb of modules (17.5mm) Packaging Indicator US1HEL D09979K 1 12 No 1 US1IHEL Q09461K 1 12 Yes 1 USGM1HEL P22294K 1 12 No 1 USGM1IHEL N22293K 1 12 Yes AMBIENT TEMPERATURE ( C) electrical Characteristics Rated Voltage (V) Nominal Current (A) 70% AMP RATINg (W) 80% AMP RATINg (W) 0% AMP RATINg (W) 00 1 HPM HPM HPM HPM HPM HPM HPM HPM HPM HPM HPM HPM HPM HPM Mersen Photovoltaic solutions 9

10 HelioProtection Fuse gpv x /1500 VDC the reverse currents. These x85 fuses, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. They are rated 1200V and 1500V and meet the trend for increasing the maximum open circuit voltage across the PV modules. DC HelioProtection Fuse complies with new IEC and with the new introducing the gpv type of fuse. BUILDINGS SOLAR FARMS Basics characteristics Size Maximum operating voltage Rated Current mm V A DxL Other ratings available on request. 12 Operation Breaking Un Power losses end contacts 0.7In 0.8In ka W W number HP15MGPV HP15MGPV16 Ref. number Packaging 8 1,3 1,7 DCHEL12C8 D14188BR 45 gpv 1,3 1,7 DCHEL12C T12017BR 45 type 12,5 1,3 1,9 DCHEL12C12,5 X08754BR ,5 2,1 DCHEL12C16 Y08755BR ,8 2,5 DCHEL12C20 Z08756BR ,2 3 DCHEL9C25 A08757BR 45 drawing Fuse clips Cat. Ref number designation Weight (g) Pack MRRESSORTCI Y098507R MR CI MRRESSORTCI Y098507T MRCI MR CI MR MR without compressor Ø Ø Ø Ø

11 Modulostar HelioProtection BUILDINGS SOLAR FARMS The Modulostar HelioProtection fuse holders from Mersen are very well known in the power low voltage distribution application market. HelioProtection Fuse gpv were specially designed for PV, and DC more generally speaking, applications. They comply with both UL512 and IEC standards and RoHS as well. The plastic parts of our Modulostar HelioProtection are UL94 V0 to V2 (Yellow Card).Two models are available: one with and one without blown fuse indication via an indicator light which is on when the fuse is blown (open circuit). The blown fuse indication operates from 350VDC up to 00VDC. Characteristics Wiring: rigid wire = 1-16mm2 (18-6AWG), use 75 C wire CO only. Screw driver heads: Mersen heads (maximum diameter 6mm). Maximum tightening torque: 2.2Nm DC20B-IP2X. Recommendations Do not operate under load. The PV source must be connected to the upstream terminal. Non insulated conductive parts: preferably the equipment should be laid out keeping the + and - polarities separate. Mounting with SPd: check that the SPD Up is compatible with the US s IU imp=6kv (see UTE C15-712). Nb of pole Cat. Ref. Nb of Mode (17.5mm) Pack Indicator 1 US1HEL D09979K 1 12 Without Ind. 1 US1IHEL Q09461K 1 12 With Ind. Nominal Voltage Ui dc 00VDC Pollution Degree 2 Voltage Isolation Uimp Nominal Current Max. power losses in the fuse links Fuse links rating Cable wire section (mm 2 ) recommended 6kV 32A 3W 2.5 6kV 32A 3W kV 32A 3W kV 32A 3W kV 32A 3W ,5 17, , Fuse clips Cat. designation Weight (g) Pack MRRESSORTCI MR CI MRRESSORT MR MRRESSORTSP MR without compressor ,27 64,5 40,5 6,5 MR CI MR MR without compressor Ø Ø Ø Ø Mersen Photovoltaic solutions 11

12 USGM1HEL UltraSafe Fuseholders BUILDINGS SOLAR FARMS Innovative UltraSafe midget fuseholders with screw-less, spring pressure, wire termination technology Mersen s new USGM series fuseholders deliver the ultimate ease-of-use, time (labor) saving and reliable solution available in the marketplace. wire termination technology into a power fuseholder, delivering the best of both technologies to its customers. They comply with UL standard and IEC Now you can and reliability of UltraSafe fuseholders and spring pressure technology. Fuse Type No. of Poles Voltage Rating Ampere Rating Photovoltaic 1 00VDC 30 Visual Indication Ref. Packaging No USGM1HEL P Yes USGM1IHEL N Recommended Fuse Usage: USGM1HEL use with Photovoltaic Fuses: HP6M, HPM. Screw-less, spring pressure terminals: WAGO CAGE CLAMP. Wire Range: #14 to 6 AWG (2.5 to 16mm 2 ) Single Conductor; #14 to AWG (2.5 to 5.0mm 2 ) Dual Conductor. Wire Type: 60/75/90 C Solid/ Stranded Copper. Ratings: Volts: 00VDC maximum Amps : 30A maximum SCCR : 200kA AC, 0kA DC 12

13 5H PRODUCT OFFERING HelioProtection Switch RESIDENTIAL BUILDINGS SOLAR FARMS These disconnect switches comply with IEC and VDE 0660 part 7 standards. These are real d.c. switches, specially designed for PV applications. HelioProtection switches are complete compact products, and are delivered already assembled with their shunts (so there s only one catalog number for the whole unit!). installation in PV applications. Category of use DC21B IT20HELCCF IT32HELCCF IT40HELCCF Ue - Operational Voltage IT70HELCCF 780 VdC 00 VdC Insulation 650 VdC 800 VdC Voltage Ref. Rated Current (A) IT20HEL6CCF P15026A IT32HEL6CCF Q15027A IT40HEL6CCF W15032A IT70HEL6CCF X15033A 60-6 IT20HELCCF M16427A VDC 8 IT25HELCCF Z11930A IT32HELCCF A11931A IT40HELCCF B11v932A IT70HELCCF E11935A of Poles 6 All our models of HelioProtection switch can be equipped with a handle for door mounting. *These HelioProtection switches are complete compact products, and are delivered already assembled with their shunts (so there s only one catalog number for the whole unit!) + Input F3 F1 F4 F Output Input A 26 Wiring diagram Input + - N N 1T3 2T1 + - Output Dimensions A E F1 F2 F3 F4 G H K L IT20HELCCF IT32HELCCF 43, ,5 45, IT40HELCCF 5, ,5 12,5 28,5 53, ,5 IT70HELCCF ,5 22,5 44,5 69, ,2 14 Input + - G N N 26 K E F3 F1 F4 F Output Input A 34 G 34 K E Input 45 Recommended tightening torque IT32HELI0CCF 1,25 Nm IT32HELI0CCF 1,80 Nm Wiring diagram 1T3 2T1 + - Output Peeling Lenght H 5 Mersen Photovoltaic solutions 13

14 FSPDB 00VDC BUILDINGS SOLAR FARMS Finger Safe Power Distribution Blocks bring extra safety to solar power systems. Starting from a primary pole, each FSPDB can distribute power to several secondary ones: 1, 4 or 8 depending on the model. Several FSPDBs can be combined to form a multipole distribution point. With the 175A to 800A FSPDB line, rigid wiring from 2.5 to 300mm 2 (aluminum or copper) can be used for connections. These products are UL Recognized. Pole (line) Load Aluminum Connector for Cu/Al 90 C wiring Copper Connector for Cu/Al 75 C wiring Rating (A) Rigid wiring cross-sectional of poles Rigid wiring cross-sectional of secondaries Nominal short circuit current FSPDB1A FSPDB1C kA FSPDB2A FSPDB2C kA FSPDB3A FSPDB3C kA FSPDB4A FSPDB4C kA FSPDB5A FSPDB5C kA dimensions Multiple wire ratings (same size & type wires only) FSPdB1 Figure 1 FSPdB2 Figure 1 FSPdB3 Figure 2 FSPdB4 Figure 1 FSPdB5 Figure 2 2/0 openings #2 openings (2) #4 AWG (2) # AWG (2) #6 AWG (2-4) #12 AWG (2) #6 AWG (2) #12 AWG (2) #8 AWG (2-4) #14 AWG (2) #8 AWG (2) #14 AWG (2-4) # AWG Accessory description FSPIN1 Multipole assembly pin dimension mm mm mm mm mm A B C D E F G H I J K FSPDB1 FSPDB4 FSPDB5 FSPDB2 FSPDB3 14

15 Surge-Trap - DC RESIDENTIAL BUILDINGS SOLAR FARMS Available in IP65 enclosure for connecting 1 to 3 strings Surge Protective Device (Thermally Protected) for PV applications. The Surge-Trap PV provides advanced overvoltage protection to photovoltaic systems by utilizing Mersen s patented TPMOV design, which does not require additional over-current protection due to its high short-circuit withstanding and its built-in disconnecting system. The Surge-Trap PV are Pluggable type SPD. The Surge-Trap PV is designed to be mounted on 35mm DIN-rail while featuring individual mode visual indication and optional remote indication, providing status to critical control circuits. Reference Rated Voltage (V) No of Poles System Type Replacement Plug STP600YPVM B15750A Y SP420PV STP00YPVM C15751A 00 3 Y SP670PV Rated Voltage (V) Ucpv Voltage Protection Level (Kv) electrical Strength (kv) Freq (Hz) Nominal discharge Current (Inom, 8/20, ka) Maximum discharge Current (Imax, 8/20, ka) ISCW (ka) STP600YPVM VDC < DC/PV STP00YPVM VDC < DC/PV consult us for Modular type SPDs. Wiring diagram STP600YPVM STP00YPVM Dimensions STP600YPVM STP00YPVM Approvals/Standards EN UTE C RoHS compliant CE UL Recognized UL A environmental & Physical characteristics Operating and storage temperature (C ): -40 to +85 Response time (ta) (ns): <25 Terminal torque (N.m): 3.5 max Enclosure material: UL 94 V0 Insulation resistance (MOhms): > Surge-Trap Microswitch diagram NO 1 Commun 2 NC 3 Subminiature Switch 125VAC-3A max Signal Wire Range: 0.05mm2 to 1.31mm2 Terminal Torque 0.25N.m max Mersen Photovoltaic solutions 15

16 Monitoring Solution electronic system to monitor from 6 to 30 PV strings by adding up to 4 AUx Card to the MAIN Card and up to 8 external sensors by adding the PROBe Card. MAIN Card / HMMC6A electrical Features of strings Max. 6 System Voltage Max. 00V Input current Max. 25A Output current Max. 150A String Voltage measurement Measurement range ± 00Vdc Presicion ± 0.5% (± 5V) String Current measurement Measurement range ± 20A Precision ± 0.5% (± 0mA) On-board Temperature measurement Measurement range -40 C to +0 C Precision ± 2 C Communication Protocol ModBUS RTU on isolated RS485 Data rate 19.2kbps (programmable) external Relay Control of outputs 3 Relay Coil power 24Vdc (max. 20mA) external Measurement and Signalling inputs SPD end-of-life status 1, potential-free input DC breaker status 1, potential-free input Auxiliary 1 & 2* 2, potential-free inputs Power Supply from PV strings Voltage Range 250Vdc to 00Vdc Power consumption 2.5W at 00Vdc external Power Supply Voltage Range 24Vdc ± % Power consumption 1.5W Mechanics Input connector Cage Clamp (6mm 2 ) Dimensions (LxPxH) in mm 190x160x35 environmental Conditions Operating temperature -30 C to +70 C Storage temperature -40 C to +80 C Relative humidity % to 95% non-condensing AUx Card / HMAC6A electrical Features of strings Max. 6 System Voltage Max. 00V Input current Max. 25A Output current Max. 150A String Voltage measurement Measurement range ± 00Vdc Precision ± 0.5% (± 5V) String Current measurement Measurement range ± 20A Precision ± 0.5% (± 0mA) On-board Temperature measurement Measurement range -40 C to +0 C Precision ± 2 C Power consumption Card consumption 0.5W Mechanics Input Connector Cage Clamp (max. 6mm 2 ) Dimensions (LxPxH) in mm 190x160x30 Same environmental conditions PROBe Card / HMPC8A Measurement inputs 1 input potential-free or pulse input Digital inputs Pulse-frequency: 0Hz to 0Hz Analog inputs - 0-V: precision ± 1% Power Consumption Card consumption 0.5W Sensor consumption Depending on the number and type of sensors Mechanics Input Connector Cage Clamp (max. 2.5mm 2 ) Dimensions (LxPxH) in mm 190x160x20 Same environmental conditions * Additional inputs (i.e.: door open, 2nd switch status ) 16

17 DC Combiner Boxes RESIDENTIAL BUILDINGS SOLAR FARMS Mersen offers a complete range of modular solutions for the most varied requirements. Designed and assembled on customer demand, DC combiner boxes can contain terminal blocks, surge protection, fuses and load circuit breakers and systems that permanently monitor the performance of the strings. Thanks to its long standing expertise in safety solutions, Mersen is performing the electrical validation Reliable Protection Polyester reinforced protecting up to IP66 to ensure a safe use outside. String performance monitoring Mersen monitoring system continuously detects the string current and the voltage. Any abnormality is detected.immediately. Fuse and fuse-holder A complete range of fuse and fuse-holder to protect PV module against overload from 1 to 30A and 600 to 1200V. A Perfect Solution for every customer s requirements Load-Break switch To isolate the DC side of a PV system load-break switch are used. Individual Solutions DC combiner box are assembled on customer demand to answer the most varied requirements. Power Distribution blocks Specially for use in the PV area, Mersen offers blocks to distribute power over wiring from 2.5 to 300mm². 0% Tested All DC combiner boxes laboratory and 0% tested after assembly. Surge protection The surge protection is using Mersen s patented TPMOV technology in a pluggable design up to 00V to meet higher demands of PV systems. Mersen Photovoltaic solutions 17

18 DC Combiner Boxes RESIDENTIAL BUILDINGS SOLAR FARMS Technical data enclosure Dimensions (HxWxP) 270 x 360 x 230 mm 308 x 255 x 150 mm 847 x 636 x 300 mm Casing IP protection class (IEC60529) IP 65 IP 65 IP 65 IK resistance classe (IEC 62262) IK 09 IK IK Colour RAL 7032 RAL 7032 RAL 7032 electrical Properties Max. rated voltage DC 00 VDC 00 VDC 00 VDC Max. current per input DC.5 A 3 A 14 A DC switching capacity (IEC ) 40 A (DC21B 00V) 20 A (DC21B 00V) 315 A (DC21B 00V) Surge Protection DC Type II / Up < 5kA - Type II / Up < 5kA Over-voltage category Cat. III - Cat. III Internal IP class IP 20 IP 20 IP 20 Inputs of DC inputs Connection DC input cable to - - Connection type DC input MC4 Connectors M16 connection, IP68, Ø: 4.5-mm MC4 Connectors Fuses yes yes yes Ouputs of DC ouputs Connection DC output cable to Connection type DC ouput M20 connection, IP68, Ø: 7-13mm M20 connection, IP68, Ø: 7-13mm M40 connection, IP68, Ø: 19-28mm Connection DC earth protection M16 connection, IP68, Ø: 4.5-mm - M20 connection, IP68, Ø: 7-13mm String Monitoring Monitoring board Circuit breaker status Surge Protection EOL External Sensors Power Supply environmental Condensation Management 2 climatic valves IP68-2 climatic valves IP68 Water evacuation 1 water drain plug IP55 1 water drain plug IP55 1 water drain plug IP55 Ambiant temperature range -20 C to +45 C -20 C to +45 C -20 C to +40 C IEC , Class II IEC , Class II Ordering Information HS5IT20VZ HS3IT40SPX HS18IT315SPX 18

19 DC Combiner Boxes with String Monitoring RESIDENTIAL BUILDINGS SOLAR FARMS enclosure 647 x 436 x 250 mm 747 x 536 x 300 mm 56 x 852 x 350 mm 56 x 852 x 350 mm IP 65 IP 65 IP 65 IP 65 IK IK IK IK RAL 7032 RAL 7032 RAL 7032 RAL 7032 electrical Properties 00 VDC 00 VDC 00 VDC 00 VDC.5 A 13 A 14 A 11 A 80 A (DC21B 00V) 0 A + 0A (DC21B 00V) 315 A (DC21B 00V) 400 A (DC21B 00V) Type II / Up < 5kA Type II / Up < 5kA Type II / Up < 5kA Type II / Up < 5kA Cat. III Cat. III Cat. III Cat. III IP 20 IP 20 IP 20 IP 20 Inputs MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors yes yes yes yes Ouputs M32 connection, IP68, Ø: 11-21mm M32 connection, IP68, Ø: 11-21mm M40 connection, IP68, Ø: 19-28mm M40 connection, IP68, Ø: 19-28mm M16 connection, IP68, Ø: 4.5-mm M16 connection, IP68, Ø: 4.5-mm M20 connection, IP68, Ø: 7-13mm M20 connection, IP68, Ø: 7-13mm String Monitoring 1 HMMC6A 1 HMMC6A + 1 HMAC6A 1 HMMC6A + 2 HMAC6A+ 1 HMPC8A 1 HMMC6A + 4 HMAC6A optional yes yes yes optional yes yes yes - - yes - self-supplied self-supplied 24 VDC ±% self-supplied environmental 2 climatic valves IP68 2 climatic valves IP68 2 climatic valves IP68 2 climatic valves IP68 1 water drain plug IP55 1 water drain plug IP55 1 water drain plug IP55 1 water drain plug IP55-20 C to +40 C -20 C to +45 C -20 C to +45 C -20 C to +40 C IEC , Class II IEC , Class II IEC , Class II IEC , Class II HM6IT80SPX HM122IT0SPX HM18IT315SPX HM18IT315SPX Mersen Photovoltaic solutions 19

20 HelioProtection Fuse HPNH 00VDC SOLAR FARMS Mersen HPNH photovoltaic (PV) fuse series was engineered HelioProtection HPNH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gpv type and comply with both IEC and UL 2579 PV standards. Global acceptance Low fault current interrupting capability Temperature cycle withstand capability Durable construction for enhanced system longevity losses Small footprint Applications All photovoltaic applications Inverter DC input protection Re-combiner applications (sub combiner, array combiner, master combiner) Ratings 00VDC IR = 50kA (L/R = 1ms) Approvals IEC UL 2579 (pending) RoHS compliance Size NH1 NH2 Rated Voltage (V) 00VDC Nominal Current (A) 50 Class Reference Watt 0% In (W) Watt 70% In (W) Package HPNH1GPV50 Z28283C HPNH1GPV63 A28284C HPNH1GPV80 B28285C HPNH1GPV0 C28286C gpv 125 HPNH1GPV125 D28287C HPNH1GPV160 E28288C HPNH2GPV200 X37619C HPNH2GPV250 Y37620C A B C d e F g H I J NH NH ,

21 HelioProtection Fuse HP12NH 1250VDC SOLAR FARMS Mersen HP12NH photovoltaic (PV) fuse series was engineered HelioProtection HP12NH fuse-links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection main fuse range enlarges our PV fuse-links offering on a size having a worldwide acceptance. They are of the gpv type and comply with both IEC and UL 2579 PV standards. Global acceptance Low fault current interrupting capability Temperature cycle withstand capability Durable construction for enhanced system longevity losses Applications All photovoltaic applications Inverter DC input protection Re-combiner applications (sub combiner, array combiner, master combiner) Ratings 1250VDC IR = 50kA (L/R = 1ms) Approvals IEC UL 2579 (pending) RoHS compliance Size NH1XL NH2XL NH3L Rated Voltage (V) 1250VDC Nominal Current (A) 125A Class Reference Power dissipation at 0.7xIn Power dissipation at In Package HP12NH1XLGPV125 G39744A A HP12NH1XLGPV160 H39745A A HP12NH2XLGPV200 J39746A A HP12NH2XLGPV250 K39747A gpv HP12NH3LGPV250 Z33389A HP12NH3LGPV315 A33390A HP12NH3LGPV350 B33391A HP12NH3LGPV400 C33392A dimensions NH1xL dimensions NH2xL dimensions NH3L (64.5) ,5 24 9, , ,5 60 (72) (84.5) ,5 2, , ,5 2,5 20 Mini = = = 127 = = (127.8) = 205 Mersen Photovoltaic solutions 21

22 HelioProtection Fuse HP15NH 1500VDC SOLAR FARMS Mersen HP15NH photovoltaic (PV) fuse series was engineered HelioProtection HP15NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gpv type and comply with both IEC and UL 2579 PV Global acceptance Low fault current interrupting capability Temperature cycle withstand capability Durable construction for enhanced system longevity losses Applications All photovoltaic applications Inverter DC input protection Re-combiner applications (sub combiner, array combiner, master combiner) Standards IEC UL 2579 (pending) RoHS compliance Size NH3L Rated Voltage (V) 1500VDC Nominal Current (A) 160 Class Reference Power dissipation at 0.7xIn Power dissipation at In Package HP15NH3LGPV160 H37859A HP15NH3LGPV200 J37860A HP15NH3LGPV250 K37861A gpv 315 HP15NH3LGPV315 L37862A HP15NH3LGPV350 M37863A HP15NH3LGPV400 N37864A (84.5) = (127.8) =

23 HelioProtection Fuse DC VDC BUILDINGS SOLAR FARMS The HelioProtection Fuse dc series are designed for the protection of cables in a PV groups of chains when a short circuit occurs in a panel. These HelioProtection fuse comply with the IeC standard They are of the gpv type. Size Minimum Breaking Capacity = 1.35In Maximum Breaking Capacity = 0kA Rated Voltage Nominal Current (A) Class ef Reference ef ef Reference ef Watt In gpv DC120GPV12C050E X03993 DC120GPV12C050P A gpv DC120GPV12C063E Y03994 DC120GPV12C063P D Watt 0.7In gpv DC120GPV12C080E Z03995 DC120GPV12C080P E gpv DC121GPV12C0E A03996 DC121GPV12C0P F gpv DC121GPV12C125E B03997 DC121GPV12C125P G gpv DC121GPV12C160E C03998 DC121GPV12C160P H gpv DC121GPV12C200E D03999 DC121GPV12C200P K gpv DC121GPV12C250E E04000 DC121GPV12C250P L gpv DC122GPV11C315E F04001 DC122GPV11C315P M gpv DC123GPVC400E G04002 DC123GPVC400P N Packaging 1 drawing (mm) 97.5 with MC2R 3E 82.5 with MCR 3E 67.5 with MC 3E 11,1 11,1 2,5 with MC2R 3E 87,5 with MCR 3E 72,5 with MC 3E with MC2R 3E 91 with MCR 3E 76 with MC 3E , , Fuse bases P/P0,7In 1.40 Corrective factor for power losses vs. ambient temperature Cat. Nb of poles Packaging SP Insulation Voltage P(T)/P(20) SE SE VDC SF I/In Ta ( C) Mersen Photovoltaic solutions 23

24 Photovoltaic Fuse-holders 00VDC NH fuse-bases for NH fuse-links gpv 00VdC, size 1, 250A, single pole HPBB11PPR Reference Power acceptance Rated impulse withstand voltage U imp design HPBB11PPR A W 8 kv open design, for DIN-rail or screw mounting, for NH fuse links size 1 HPBB11PPRFS K W 8 kv with touch protection, for DIN-rail or screw mounting, for NH fuse links size 1 Package 3 3 HPBB21PPR NH fuse-bases for NH fuse-links gpv 00VdC, size 2, 315A, single pole Reference Power acceptance Rated impulse withstand voltage U imp design HPBB21PPR C W 8 kv open design, for DIN-rail or screw mounting, for NH fuse links size 1 and 2 HPBB21PPRFS D W 8 kv with touch protection, for DIN-rail or screw mounting, for NH fuse links size 1 and 2 Package 3 3 NH fuse-base for short NH fuse-links gpv, sizes 1, type PP, open design (dimensions in mm) , Ø 20,5 Ø,5 250 M In case of multipole units in parallel without barriers a distance of 8mm must be considered between the live parts of the fuses. NH fuse-base for short NH fuse-links gpv, sizes 2, type PP, open design (dimensions in mm) Ø Ø 20.5 M In case of multipole units in parallel without barriers a distance of 8mm must be considered between the live parts of the fuses

25 NH fuse-base for short NH fuse-links gpv, sizes 1, type PP with touch protection (dimensions in mm) 87 67, , Ø 20,5 Ø,5 111, M , NH fuse-base for short NH fuse-links gpv, sizes 2, type PP with touch protection (dimensions in mm) 87 67, , Ø 20,5 Ø, , M NH Fuse handle for NH fuse links size 00-4 NHHANDLE Reference Size design Weight Package NHHANDLE P215592E 00 to 4 without arm protection to DIN VDE , DIN VDE X2165A 00 to 4 DIN VDE g g Mersen Photovoltaic solutions 25

26 Photovoltaic Fuse-holders 1500VDC - open version Open Fuse bases for NH long fuse-links gpv up to 1500VdC, 1 pole, SCCR 50kA Reference Power acceptance Rated impulse withstand voltage U imp Rating design Package SP36121 B kV 250 open design, screw mounting, for NH1Xl fuse link 1 SP P kV 630 open design screw mounting, for NH2Xl and NH3L fuse links 1 dimensions SP36121 NH Fusehandle for long fuses 199,5 141,5 POIGNEEPM12 Reference Y2402A 8, ,5 270,5 14 8,5 302,5 125,5 2 holes Ø 8, , dimensions SP , , holes Ø 8,

27 Photovoltaic Fuse-holders 1500VDC - protected version Protected fuse-bases for NH long fuse-links gpv up to 1500VdC, one pole, SCCR 15kA Reference Power acceptance Rated impulse withstand voltage U imp * can accept Mersen gpv fuse-links size 121 and NH2XL rated 250A with derating. ** can accept NH3L fuses up to 630A with derating. Rating design Package HPBB1XL1PPFS Y kV 250A With touch protection, screwmounting, for NH1XL fuse-links* HPBB2XL3L1PPFS Z kV 500A With touch protection, screwmounting, for NH2XL and NH3L fuselinks** HPBB2XL3L1PBFS A kV 500A With touch protection, screwmounting, busbar output, for NH2XL and NH3L fuselinks mind A HPBB1xL1PPFS Ø, NH-1XL mind. 6 Schnitt A-A 97,6 1, A 216,9 15,7 Ø, mind. 6 Ø, ,7 215, HPBB2xL3LPPFS ,7 30 HPBB2xL3LPBFS ,7 Mersen Photovoltaic solutions 27

28 Main production sites Industrial or commercial branch A WORLD LEADER in safety & reliability for electrical power Global expert in materials and equipment for extreme environments and in the safety and reliability of electrical equipment. A GLOBAL PLAYER Mersen designs innovative solutions to address its clients specific needs to enable them to optimize their manufacturing process in sectors such as Energy, Transportation, Electronics, Chemical, Pharmaceutical and Process Industries. BR-HELIO MERSEN France SB S.A.S. Rue Jacques de Vaucanson F Saint-Bonnet-de-Mure Tel: MERSEN Shanghai Co. Ltd. No.55-A6. Shu Shan Road, Songjiang Shanghai Tel: MERSEN USA Newburyport-MA L.L.C. 374 Merrimac Street Newburyport, MA Tel: ep.mersen.com

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic

More information

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1)

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) THE COMMITMENT OF MERSEN IN SAFER AND MORE RELIABLE SOLAR PHOTOVOLTAIC INSTALLATIONS In the solar market Mersen is a driving force in the

More information

issue 5 Solar solutions designed by Ferraz Shawmut Power generation & distribution Industrial controls Power quality

issue 5 Solar solutions designed by Ferraz Shawmut Power generation & distribution Industrial controls Power quality 1 Program Solar solutions designed by Ferraz Shawmut issue 5 www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Helio Protection.   Solar solutions designed by Ferraz Shawmut. Power generation & distribution. 1 Helio Protection Solar solutions designed by Ferraz Shawmut www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

Program Solar solutions designed by Ferraz Shawmut

Program Solar solutions designed by Ferraz Shawmut 1 Program Solar solutions designed by Ferraz Shawmut issue 4 www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

American Round Fuses - Form 101 range

American Round Fuses - Form 101 range Form 0 A5QS - 50 Vac A5QS- D007J 0 A5QS- E007J 0 A5QS- F0074J 0 4 A5QS4- G0075J 0 5 A5QS5- H007J 0 A5QS- J0077J 0 7 A5QS7- K0078J 0 8 A5QS8- L0079J 0 0 A5QS0- N008J 0 A5QS- P008J 0 5 A5QS5- Q008J 0 0 A5QS0-

More information

SOLAR POWER. Electrical Protection Solutions

SOLAR POWER. Electrical Protection Solutions SOLR POWER Electrical Protection Solutions solar power Mersen Keeps it safe & reliable global leader with a century of experience, Mersen brings expertise and innovation to your company Increase system

More information

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw Modulostar Motor Branch 400V AC - 690V AC up to 11 kw Innovations in MODULOSTAR to control energy in motor starters Already active in the field of motor starters with rated current over 32A per phase,

More information

Fused Coordination Panelboard

Fused Coordination Panelboard Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Solar Power Product SOLUTIONS GUIDE. Comprehensive photovoltaic protection

Solar Power Product SOLUTIONS GUIDE. Comprehensive photovoltaic protection Solar Power Product Solutions SOLUTIONS GUIDE Comprehensive photovoltaic protection solar power Mersen Keeps it safe & reliable A global leader with a century of experience, Mersen brings expertise and

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

Power Electronics. Serving the Power Electronics Market. Safety & Reliability

Power Electronics. Serving the Power Electronics Market. Safety & Reliability Power Electronics Serving the Power Electronics Market Safety & Reliability for Electrical Power Your partner should be a global leader Global expertise The Mersen Group is a global expert in materials

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

Medium Voltage Controllable Fuse

Medium Voltage Controllable Fuse Medium Voltage Controllable Fuse SOLUTIONS GUIDE SOLUTIONS GUIDE Intelligent Fuse Technology Introducing the Next Generation of Medium Voltage Arc-Flash Protection Mersen s new Medium Voltage Controllable

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD BRANCH CIRCUIT PROTECTION FUSED COORDINATION BOARD MERSEN S FUSED COORDINATION BOARD Selective Coordination is required in several locations as defined in the National Electrical Code (NEC). Mersen s Fused

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

A powerful way to manage your power distribution challenges. I Power Distribution Blocks I Power Distribution Blocks A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs... Power Distribution Blocks I A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

High-Voltage Fuse Links according to IEC

High-Voltage Fuse Links according to IEC High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

Medium voltage fuses - European Fuses

Medium voltage fuses - European Fuses HV Back-up Fuse-Links according to IEC 60 282- HV fuse-links have been used for reliable protection in medium-voltage switchgear and controlgear and systems for decades. They protect apparatus and equipment

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Complete and reliable solar circuit protection

Complete and reliable solar circuit protection Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Solar circuit protection application guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage High-Voltage Fuse-Links according to VDE 0670 T 402 Hi gh-voltage Limitor Notes 2 Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical

More information

Bussmann Circuit Protection Solutions. PV Combiner Box Solutions Photovoltaic Protection Made Simple

Bussmann Circuit Protection Solutions. PV Combiner Box Solutions Photovoltaic Protection Made Simple Bussmann Circuit Protection Solutions PV Combiner Box Solutions Photovoltaic Protection Made Simple Anatomy of a Bussmann Combiner Box PV Surge Protection Device (SPD) Class I or Class II Optional 240Vac

More information

Power Transfer for Rail Vehicles SOLUTIONS GUIDE

Power Transfer for Rail Vehicles SOLUTIONS GUIDE Power Transfer for Rail Vehicles SOLUTIONS GUIDE Commuting, sightseeing, moving... 400 different projects all Mersen provides expertise to customers for safety & reliability of electrical power We integrate

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Technical specifications

Technical specifications KINGDOM OF SAUDI ARABIA THE SAUDI FUND FOR DEVELOPMENT ( SFD) ITB -207-7 Technical specifications Project name: Reconstruction, Furniture and Equipping of Three Schools Photovoltaic Solar System for Holly

More information

PSC Protection Semiconductor Square Body Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE

PSC Protection Semiconductor Square Body Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE PSC Protection Semiconductor Square Fuses Now manufactured in North America for faster delivery to our North American consumers SOLUTIONS GUIDE PSC Square Fuses: Built with speed in mind Mersen s high-performance

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and adaptive technology. This technology is improving

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A Technical Data Effective March 0 Bussmann x38mm Photovoltaic fuses Operating class gpv and UL PV fuse links PV Fuse coordination With thin film cells and, 5 and crystalline silicon cells Description A

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information