1 BS LV Fuse Links Catalog 00 Blue Dot

2 Ferraz Shawmut Powerful presence of the world s leader on the circuit protection market Ferraz Shawmut, Carbone Lorraine s Electrical Protection Division, offer innovative solutions to enhance the safety of low and medium voltage installations and equipment. Above and beyond the supply of products, the company also provides added value in the form of technical support for OEMs, electrical contractors, panel builders, plant maintenance department and utilities. As a global player, Ferraz Shawmut has established production facilities on every continent to optimize the offering (France, Tunisia, United States, Canada, Mexico, India, Japan and P.R. of China). All these locations are united around a global quality, safety and environment policy. The world-class organization of Ferraz Shawmut offers tried, proven and approved solutions ensuring the integrity of the equipment their devices protect and the safety of people working around them. To guard customers electrical equipment and installations over the long term, Ferraz Shawmut markets the widest range of safe, reliable electrical and thermal protection solutions. Ferraz Shawmut solutions are sold all over the world at 500 points of sale through professional distributors of electrical components and equipment.

3 Blue Dot Blue Dot is the brand name of the Ferraz Shawmut s BS General Purpose Fuse and Fusegear range of products. Blue Dot brand provides you with high-quality products designed and manufactured by Ferraz Shawmut in compliance with ISO 9001 Standard. All the circuit protection solutions advertised in this catalogue are ASTA 0 certified and comply with the RoHS European Directive. Contents Offset Bolted Tag Fuses Links (A-type) Reference Data... Dimensions & Electrical Characteristics...5 Central Bolted Tag Fuses Links (B&C-type) Reference Data... Dimensions & Electrical Characteristics...7 Curves Set for A, B & C Type Offset Blade Tag Fuses Links (F-type) Reference Data & Dimension... Curves Set for F Type...11 Cut-off Current Characteristics for Blue Dot...1 Approvals...13 Application Information...1 Comparison Chart...15

4 Offset Bolted Bolted Tag Fuses Tag Links (A-type) Fuse Links (A-type) Offset Bolted Tag Offset Fuse Bolted Tag Links Fuses Links (A-type) Reference data Rated Voltage: 15V ac Breaking Capacity: 0kA Rating Catalog Reference BS Standard IEC Standard Designation Pack. (A) Number Number Reference Reference (Fuse Type) BNITV N3J BS- IEC09- A1 BNITV PJ BS- IEC09- A1 BNITV Q5J BS- IEC09- A1 BNITV RJ BS- IEC09- A1 1 BNITV1 S7J BS- IEC09-1A1 0 BNITV0 TJ BS- IEC09-0A1 5 BNITV5 V9J BS-1 IEC09-1 5A1 3 BNITV3 W70J BS-1 IEC09-1 3A1 5 BNITV0M5 X71J BS- IEC09-0M5A1 3 BNITV0M3 Y7J BS- IEC09-0M3A1 BTIAV Z73J BS- IEC09- A BTIAV A7J BS- IEC09- A BTIAV B75J BS- IEC09- A BTIAV C7J BS- IEC09- A 1 BTIAV1 D77J BS- IEC09-1A 0 BTIAV0 V733J BS- IEC09-0A 5 BTIAV5 E7J BS- IEC09-5A 3 BTIAV3 F79J BS- IEC09-3A 0 BTIAV3M0 G0J BS- IEC09-3M0A 50 BTIAV3M50 H1J BS- IEC09-3M50A 3 BTIAV3M3 K3J BS- IEC09-3M3A 0 BTISV0 LJ BS- IEC09-0A3 50 BTISV50 M5J BS- IEC09-50A3 3 BTISV3 NJ BS- IEC09-3A3 0 BTISV0 P7J BS-1 IEC09-1 0A3 0 BTISV0 QJ BS-1 IEC09-1 0A3 0 BTISV3M0 R9J BS- IEC09-3M0A3 0 BTISV3M0 S90J BS- IEC09-3M0A3 3 BTCPV3 T91E BS- IEC09-3A 5 0 BTCPV0 V9E BS- IEC09-0A 5 50 BTCPV50 W93E BS- IEC09-50A 5 3 BTCPV3 X9E BS- IEC09-3A 5 0 BTCPV0 Y95E BS- IEC09-0A 5 0 BTCPV0 Z9E BS- IEC09-0A 5 15 BTCPV0M15 A97E BS- IEC09-0M15A 5 BTCPV0M B9E BS- IEC09-0MA 5 00 BTCPV0M00 C99E BS- IEC09-0M00A 5 15 BTFPV15 D300E BS-1 IEC AX 5 BTFPV E301E BS-1 IEC09-1 AX 5 00 BTFPV00 F30E BS-1 IEC AX 5 50 BTFPV00M50 G303E BS-1 IEC M50AX BTFPV00M315 H30E BS-1 IEC M315AX 5

5 Dimensions Offset Bolted Tag Offset Fuse Bolted Tag Links Fuses Links (A-type) E D G A Pos. Fuse Current Rating Dimensions No. Type (A) A max B max D max E max F nom G nom H nom K max 01 BNIT,,,,1,0,5,3,0M5,0M BTIS 0,50, BTIS 0,0,3M0,3M Pos. Fuse Current Rating Dimensions No. Type (A) A max B max D max E max F nom G nom J nom H nom K max 01 BTIA,,,,1,0,5, BTIA 3M0,3M50,3M BTCP 3,0,50,3,0, BTCP 0M15,0M,0M BTFP 15,, BTFP 00M50,00M Electrical characteristics Fuse Rating Curve I t (Ampere seconds) Watts Type (A) Pre Arcing Total Loss BNIT/BTIA gg BNIT/BTIA gg BNIT/BTIA gg 0 1. BNIT/BTIA gg BNIT/BTIA 1 gg BNIT/BTIA 0 gg BNIT/BTIA 5 gg BNIT 0M5 gm BNIT/BTIA 3 gg BNIT 0M3 gm BTCP 3 gg BTIS/BTCP 0 gg BTIA 3M0 gm BTIS/BTCP 50 gg BTIA 3M50 gm BTIS/BTCP 3 gg BTIA 3M3 gm BTIS/BTCP 0 gg BTIS 3M0 gm BTIS/BTCP 0 gg BTIS 3M0 gm BTFP 15 gg BTCP 0M15 gm BTFP gg BTCP 0M gm BTFP 00 gg BTCP 0M00 gm BTFP 00M50 gm BTFP 00M315 gm H K F B Offset Bolted Bolted Tag Fuses Tag Links (A-type) Fuse Links (A-type) 5

6 Central Bolted Bolted Tag Fuse Links Tag (B Fuse & C-Type) Links (B & C-Type) Central Bolted Tag Central Fuse Bolted Links Tag Fuse (B Links & (B & C-Type) Reference data Rated Voltage: 15V ac Breaking Capacity: 0kA Rating Catalog Reference BS Standard IEC Standard Designation Pack. (A) Number Number Reference Reference (Fuse Type) 3 BTBCV3 J305J BS- IEC09-3B1X 0 BTBCV0 K30J BS- IEC09-0B1X 50 BTBCV50 L307J BS- IEC09-50B1X 3 BTBCV3 M30J BS- IEC09-3B1X 0 BTCV0 N309E BS- IEC09-0B1 5 0 BTCV0 P3E BS- IEC09-0B BTCV0M15 Q311E BS- IEC09-0M15B1 5 BTCV0M R31E BS- IEC09-0MB BTCV0M00 S313E BS- IEC09-0M00B BTFV15 T31E BS- IEC09-15B 5 BTFV V315E BS- IEC09- B 5 00 BTFV00 W31E BS- IEC09-00B 5 50 BTFV00M50 X317A BS- IEC09-00M50B BTFV00M315 Y31A BS- IEC09-00M315B 1 50 BTKFV50 Z319A BS- IEC09-50B BTKFV315 A30A BS- IEC09-315B BTKFV315M00 B31A BS-1 IEC M00B BTKMV50 C3A BS-1 IEC B3X BTKMV315 D33A BS-1 IEC B3X BTMFV355 E3A BS- IEC09-355B 1 00 BTMFV00 F35A BS- IEC09-00B BTMV355 G3A BS- IEC09-355C BTMV00 H37A BS- IEC09-00C BTTMV50 J3A BS- IEC09-50C BTTMV500 K39A BS- IEC09-500C 1 50 BTTMV50 L330A BS- IEC09-50C 1 30 BTTMV30 M331A BS- IEC09-30C 1 70 BTLMV70 N33A BS- IEC09-70C3 1 7 BTLMV7 P333A BS- IEC09-7C BTLMV750 Q33A BS- IEC09-750C BTLMV00 R335A BS- IEC09-00C3 1

7 Central Bolted Tag Central Fuse Bolted Links Tag Fuse (B Links & (B & C-Type) Dimensions Pos. Fuse Current Rating Dimensions No. Type (A) A max B max D max E max F nom G nom H nom J nom 01 BTC/BTBC 3,0,50,3,0, BTC 0M15,0M,0M BTF 15A,A,00A BTF 00M50,00M BTKF 50, BTKF 315M BTKM 50, BTMF 355, Pos. Fuse Current Rating Dimensions No. Type (A) A max B max D max E max F nom G nom H nom J nom L nom 01 BTM 355, BTTM 50,500,50, BTLM 70,7,750, Electrical characteristics Fuse Rating Curve I t (Ampere seconds) Watts Type (A) Pre Arcing Total Loss BTBC 3 gg BTBC 0 gg BTBC 50 gg BTBC 3 gg BTC 0 gg BTC 0 gg BTF 15 gg BTC 0M15 gm BTF gg BTC 0M gm BTF 00 gg BTC 0M00 gm BTKF/BTKM 50 gg BTF 00M50 gm BTKF/BTKM 315 gg BTF 00M315 gm BTMF/BTM 355 gg BTMF/BTM 00 gg BTKF 315M00 gm BTTM 50 gg BTTM 500 gg BTTM 50 gg BTTM 30 gg BTLM 70 gg BTLM 7 gg BTLM 750 gg BTLM 00 gg Central Bolted Bolted Tag Fuse Links Tag (B Fuse & C-Type) Links (B & C-Type) 7

8 Curves Set for Set A, B for & C Type A, B & C Type Curves Set for Curves A, Set B for & A, C B & C Type Time (seconds) Time vs. Current characteristics gg curves - to 00A - 15VAC,000 1, A A A A 1A 0A 5A 3A 0A 50A 3A 0A 0A 0 Current (Amperes) 00 Time (seconds),000 1, A A 00A 50A 315A 355A 00A 50A 500A 50A 30A 70A 7A 750A 00A 00,000 0,000 gm curves - 0M5 to 315M00A - 15VAC, , M0A 3M3A 3M50A 3M0A 0M3A 0M5A 315M00A 00M315A 00M50A 0M00A 0MA 0M15A 3M0A ,000,000 3,000 5,000 7,000,000 0,000 Current (Amperes) Time (seconds) Current (Amperes)

9 Curves Set for Curves A, Set B for & A, C B & C Type I t characteristics I t let-through (Ampere seconds) total I 15V pre-arcing I t Curves Set for Set A, B for & C Type A, B & C Type 0 Fuse-link rating (A) Power dissipation chart Power dissipation (Watts) Current rating (A) 9

10 Offset Blade Blade Tag Fuse Tag Links (F-Type) Fuse Links (F-Type) Offset Blade Tag Offset Fuse Blade Tag Links Fuse Links (F-Type) Reference data Rated Voltage: 15V ac - Breaking Capacity: 0kA Dimensions Rating Catalog Reference BS Standard IEC Standard Designation Pack. (A) Number Number Reference Reference (Fuse Type) BNSV S33J BS- IEC09- F1 BNSV T337J BS- IEC09- F1 BNSV V33J BS- IEC09- F1 BNSV W339J BS- IEC09- F1 1 BNSV1 X30J BS- IEC09-1F1 0 BNSV0 Y31J BS- IEC09-0F1 5 BNSV5 Z3J BS- IEC09-5F1 3 BNSV3 A33J BS- IEC09-3F1 5 BNSV0M5 B3J BS- IEC09-0M5F1 3 BNSV0M3 C35J BS- IEC09-0M3F1 BESV D3J BS- IEC09- F 1 BESV1 E37J BS- IEC09-1F 0 BESV0 F3J BS- IEC09-0F 5 BESV5 G39J BS- IEC09-5F 3 BESV3 H350J BS- IEC09-3F 0 BESV0 J351J BS- IEC09-0F 50 BESV50 K35J BS- IEC09-50F 3 BESV3 L353J BS- IEC09-3F Pos. Fuse Current Rating Dimensions No. Type (A) A max B max D max E max F nom N nom 01 BNS,,,,1,0,5,3,0M5,0M BES,1,0,5,3,0,50, Electrical characteristics Fuse Rating Curve I t (Ampere seconds) Watts Type (A) Pre Arcing Total Loss BNS gg BNS gg BNS gg 0 1. BNS/BES gg BNS/BES 1 gg BNS/BES 0 gg BNS/BES 5 gg BNS 0M5 gm BNS/BES 3 gg BNS 0M3 gm BES 0 gg BES 50 gg BES 3 gg

11 Curves Curves Set F Set F Type Time vs. Current characteristics gg curves - to 3A - 15VAC Time (seconds), , A 3A 50A A A A A 1A 5A 0A 3A Curves Set F Set Type F Type ,000 Current (Amperes) I t characteristics I t let-through (Ampere seconds) Power dissipation (Watts) Power dissipation chart Fuse-link rating (A) Current rating (A) 11

12 Cut-off Current Current Characteristics Characteristics Cut-off Current Cut-off Current Characteristics Cut-off Current (ka PEAK) Cut-off Current Characteristics A,B,C & F Type Prospective Current (Sym. R.M.S. ka) 1

13 Approvals Approvals 13

14 Application Application Information Application Information Information Voltage rating selection BS fuses comply with IEC 09 standards. They are tested under a voltage at least % higher than the fuse rated voltage. Ambient Temperature Above an ambient of 0 C a general de-rating of 0.5% of the fuse-link ratied current per excess degree centigrade is recommended Cable protection gg fuses protect cables against both overload and short circuit current. The cable is protected when the following conditions are fulfilled: I B : operating current of the cable I Z : maximum current carrying capacity of the cable I N : rated current of the fuse I F : conventional fusing current of the fuse Capacitor circuit protection The fuse selection must take into account: - the inrush current occurring when the capacitor is switched on - the harmonic currents during the normal operation of the network - Capacitor tolerances The fuse link should be chosen with a current rating greater than 1.7 times the rated capacitor current. Correction for ambient temperature higher than 0 C must be added. Transformer protection Fuses must be fitted both in the primary and the secondary of the transformer. The fuse selection must take into account the high transient inrush current in the primary of the transformer. Consequently the normal current rating of the fuse links on the primary side of transformers should be at least twice the nominal transformer primary current. The normal IN value of the fuse links on the secondary side of transformers is at least equal to the nominal transformer secondary current when the temperature does not exceed 0 C. Motor circuit protection The motor starters manufacturer generally recommend the fuse link rating to be used in conjunction with the motor starter. Type co-ordination is easily obtained with FERRAZ SHAWMUT fuses in view of having the pre arcing It values closer to the lower limit of the specified limits of the standard. The gm fuse selection as for an am fuse requires the melt current at 5s is 7 times the fuse rating. Protection against electrical shock The rule is to disconnect within a time specified by local standards. Generally wiring regulations require a disconnecting time not exceeding 5 seconds for a distribution circuit. It will be less than 1 second in many other cases. Rating (A) Z s (Ohms) Rating (A) Z s (Ohms) for more information, please contact our Technical Support : ts@fr.ferrazshawmut.com 1

15 Comparison Chart Comparison chart for BS LV Fuse links NIT TIA TIS TCP TFP TBC TC TF TKF TKM TMF TM TTM TLM NS MES Competitors NITD AAO BAO CEO DEO BD CD DD ED EFS ED EF FF GF NSD ESD FERRAZ SHAWMUT BNITVx BTIAVx BTISVxx BTCPVxx BTFPVxxx BTBCVxx BTCVxx BTFVxxx BTKFVxxx BTKMVxxx BTMFVxxx BTMVxxx BTTMVxxx BTLMVxxx BNSVx BESVxx This list is intended for guidance only. Ferraz Shawmut do not guarantee identical performance for the comparative types. It is essential that the performance characteristics are checked to ensure compatibility Ferraz Shawmut Numbering System Comparison Chart Chart BS LV Industrial fuse links B NIT V xxx BS Part Number Rated Voltage Current Rating (15V AC) BS LV Industrial fuse links Motor Rated B NIT V xxmxx BS Part Number Rated Voltage Current Rating (15V AC) 15

16 DISTRIBUTOR: 37 Merrimac Street Newburyport, MA USA Tél. (97) - - Fax (97) , rue Jean Novel 9 VILLEURBANNE Cedex - FRANCE Tél. 33 (0) Fax 33 (0) A-3, Essae Industrial Estate, /3 Begur Hobli Road, Bommanahalli, Bangalore Tel: / 03 - Fax: Amalgame - 0/00

BS88 LV Fuse Links & Holders Catalogue Blue Dot

BS88 LV Fuse Links & Holders Catalogue Blue Dot BS88 LV Fuse Links & Holders Catalogue 009 Blue Dot Ferraz Shawmut Powerful presence of the world s leader on the circuit protection market Ferraz Shawmut, Carbone Lorraine s Electrical Protection Division,

More information

BS88 LV Fuse Links & Fuse Holders TECHNICAL GUIDE

BS88 LV Fuse Links & Fuse Holders TECHNICAL GUIDE BS88 LV Fuse Links & Fuse Holders TECHNICAL GUIDE MERSEN Powerful presence of the world s leader on the circuit protection market, Mersen Electrical Protection Activity, offer innovative solutions to enhance

More information

SPECIALIST FUSES SPRING

SPECIALIST FUSES SPRING SPECIALIST FUSES SPRING 2017 We keep businesses moving Rexel understands your business-critical need to get the right fuses on site at the right time, and our Specialist Fuses division exists to provide

More information

American Round Fuses - Form 101 range

American Round Fuses - Form 101 range Form 0 A5QS - 50 Vac A5QS- D007J 0 A5QS- E007J 0 A5QS- F0074J 0 4 A5QS4- G0075J 0 5 A5QS5- H007J 0 A5QS- J0077J 0 7 A5QS7- K0078J 0 8 A5QS8- L0079J 0 0 A5QS0- N008J 0 A5QS- P008J 0 5 A5QS5- Q008J 0 0 A5QS0-

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw Modulostar Motor Branch 400V AC - 690V AC up to 11 kw Innovations in MODULOSTAR to control energy in motor starters Already active in the field of motor starters with rated current over 32A per phase,

More information

High-Voltage Fuse Links according to IEC

High-Voltage Fuse Links according to IEC High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative

More information

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage High-Voltage Fuse-Links according to VDE 0670 T 402 Hi gh-voltage Limitor Notes 2 Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical

More information

IEC FUSES & FUSEGEAR BS88 LV FUSE LINKS & FUSE HOLDERS

IEC FUSES & FUSEGEAR BS88 LV FUSE LINKS & FUSE HOLDERS IEC FUSES & FUSEGER S88 LV FUSE LINKS & FUSE HOLDERS MERSEN Powerful presence of the world s leader on the circuit protection market, Mersen Electrical Protection ctivity, offer innovative solutions to

More information

HRC Fuse Links Low Voltage Industrial SAFECLIP. NH DIN Standard RED SPOT / SAFECLIP / NH

HRC Fuse Links Low Voltage Industrial SAFECLIP. NH DIN Standard RED SPOT / SAFECLIP / NH GE Power Controls HRC Fuse Links Low Voltage Industrial RED SPOT Standard RED SPOT 400 Series RED SPOT / SAFECLIP / NH SAFECLIP NH DIN Standard RED SPOT / SAFECLIP / NH RED SPOT / SAFECLIP / NH Low Voltage

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

gg ferrule-style fuses

gg ferrule-style fuses gg 8.5 x 31.5-400V Size Current Voltage Cat. number Ref. number Cat. number Ref. number Voltage Ref. number Cat.number Pckg (A) (V) w/o indicator w/o indicator with indicator with indicator (V) with striker

More information

GE Power Controls. Low Voltage HBC Fuselinks. For more information, please contact: MAJESTIC GLOBAL LTD.

GE Power Controls. Low Voltage HBC Fuselinks. For more information, please contact: MAJESTIC GLOBAL LTD. GE Power Controls Low Voltage HBC Fuselinks For more information, please contact: MAJESTIC GLOBAL LTD. www.mgl.hk GE Power Controls type NS/T/TS range of High Breaking Capacity (HBC) fuselinks are extensively

More information

Medium voltage fuses - European Fuses

Medium voltage fuses - European Fuses HV Back-up Fuse-Links according to IEC 60 282- HV fuse-links have been used for reliable protection in medium-voltage switchgear and controlgear and systems for decades. They protect apparatus and equipment

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Low Voltage Industrial Type T Fuse Links

Low Voltage Industrial Type T Fuse Links Low Voltage Industrial Type T Fuse Links Type T HRC Fuse Links for Industrial and General Application Contents Introduction 2 Performance Data 3 List Numbers and Dimensions 4 Utilisation Categories 8 Application

More information

Red Spot centre bolted tags fuse links

Red Spot centre bolted tags fuse links Supersedes July 2015 BUSSMANN SERIES Red Spot bolted tags Product description Eaton s Bussmann series Red Spot tagged BS (in sizes B1 to B4 and C1 to C3 and D1) are specifically designed for the protection

More information

IEC and British Standard Fuses.

IEC and British Standard Fuses. IEC and British Standard Fuses Section Contents Page Application Data..................... 45-46 CSA Type P and Type D fuses (CDS, CDN & PON)............................47 Tron HRC Form II Class C fuses

More information

Loadswitch. Fuse Combination Units

Loadswitch. Fuse Combination Units Loadswitch Dorman Smith Switchgear Limited With over 130 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high quality equipment for lowvoltage

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

Bussmann series Red spot range offset bolted tags fuse links

Bussmann series Red spot range offset bolted tags fuse links Supersedes June 2015 Product description SERIES Eaton s Red Spot offset bolted tags BS fuse links (in sizes A1 to A4) are specifically designed for the protection of general industrial applications, e.g.

More information

HRC Fuselinks & Installation Accessories BILL MEANS BUSINESS

HRC Fuselinks & Installation Accessories BILL MEANS BUSINESS HRC Fuselinks & Installation Accessories BILL MANS BUSINSS Fuselinks Fuselinks Product uide Installation Accessories Replacement Fuse Carriers Switchboard Accessories 67 HRC Fuselinks Offset Contact HRC

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry. SIRIUS Innovations. Technical information for ring terminals SIRIUS Answers for industry. Order data Assembly up to 7.5 kw (S00) fused assembly 2 Motor Starter (Fuses, Contactor, Overload Relay) Contactor

More information

Low Voltage Catalogue. Domestic Applications to BS1361 & BS1312. Consumer Unit Fuse Link 240V / 5-45 A. Plug Top Fuse Links 240V / 1-13A

Low Voltage Catalogue. Domestic Applications to BS1361 & BS1312. Consumer Unit Fuse Link 240V / 5-45 A. Plug Top Fuse Links 240V / 1-13A Domestic Applications to BS1361 & BS1312 Consumer Fuse Link 240V / 5-45 A Description: Cylindrical Fuse Links for domestic application according to BS1361 Volts: - 240V Amps: - 5-45A IR - 16.5kA Applications:

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

Order No. of the options EMC filter Class A

Order No. of the options EMC filter Class A Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Fuse Combination Units

Fuse Combination Units Fuse Combination Units Loadswitch Range Fuse Combination Units (16-800A) O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E Dorman Smith Switchgear Ltd With over 130 years of experience

More information

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI Application Dimensional drawings Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +550 C. Design Two support rings with replaceable orifice disk

More information

UL248 North American Low Voltage Fuses

UL248 North American Low Voltage Fuses UL248 North American Low Voltage Fuses UL198 : Old low voltage fuse standards UL standards UL248 : New old voltage fuse standards UL512 : Fuse block standards 2/ 23 They establish : UL standards The dimensional

More information

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit. 1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.

More information

High Power Switchgear. We can create a solution that s both effective and cost-effective

High Power Switchgear. We can create a solution that s both effective and cost-effective High Power Switchgear We can create a solution that s both effective and cost-effective Switch Application Questionnaire Customer: Address: State/Zip: Contact: Project Name: Electrical Data Switch to operate:

More information

Paramount HRC Cartridge

Paramount HRC Cartridge Paramount HRC Cartridge Eaton MEM HRC fuselinks are manufactured to exacting standards using precision assembly methods and undergo rigorous quality checking before dispatch including resistance testing

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

PRICE LIST EFFECTIVE

PRICE LIST EFFECTIVE 17 2017 Price List Contents PRICE LIST EFFECTIVE - 2017 Low Fuse Links & Fuse Holders HRC Fuse Fittings & Bases 1 Low BS88 of Fuse Links 1-4 Low NH of Fuse Links 5 Highspeed Fuse Links BS 88 Semi-Conductor

More information

MAC VALVES, INC. Rev. T

MAC VALVES, INC. Rev. T REVISION LEVEL DATE RELEASED CHANGE DESCRIPTION ECN NUMBER P.E. APPROVAL P.D APPROVAL A 5-11-95 ENGINEERING RELEASE 12727 EPJ B 1-15-96 ADDED 35 SERIES 13228 EPJ ADDED MOD 2938 TO 6500 SERIES, MODS 2910

More information

INSTRUMENT PANEL CLUSTERS

INSTRUMENT PANEL CLUSTERS INSTRUMENT PANEL CLUSTERS NOT BUYING AT THIS TIME REVISED ##### PART # MAKE APPLICATION 6/18/2018 PRICE 56045618 CHRY IPC 40.00 56045679 CHRY IPC 40.00 56051103 CHRY IPC 40.00 56049833 AC,AD CHRY IPC 40.00

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in 4 6 Air return Manual operator Solenoid 4-way pilot with balanced poppet Bonded spool 2 7 8 2 67

More information

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

Bussmann series NH catalogue. Leadership in circuit protection

Bussmann series NH catalogue. Leadership in circuit protection Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale) Version 1.0 Grade boundaries June 2018 exams GCSE Reformed (subjects which use the 9 to 1 grade scale) This document presents grade boundaries for the new reformed GCSEs which use the 9 to 1 grade scale.

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion. 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! F.A.A.-P.M.A. MODEL 1U128A AND 1U128B REVISION 17 February 21, 2002 VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! The following information applies to all installations

More information

~... se_rv_ic_e M_A_NU_AL_2_44_4._z1,~

~... se_rv_ic_e M_A_NU_AL_2_44_4._z1,~ WABCO... se_rv_ic_e M_A_NU_AL_2_44_4._z1, DN-11 DC NEUTRAL RELAYS PARTS LIST This service manual provides parts lists for 4-, 6-, 8-, and IO-point DN-11 DC Neutral Relays. Included in this Parts List is

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories ,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker

More information

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017 HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH

More information

FERRAZ SHAWMUT IS NOW. Fuses Fusegear

FERRAZ SHAWMUT IS NOW. Fuses Fusegear FERRAZ SHAWMUT IS NOW Fuses Fusegear FOUR KEY ASSETS TO SERVE FIVE MARKETS As the global specialist in electrical and thermal protection for electrical equipment in industry, Ferraz Shawmut serves five

More information

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax 652 Oliver Street Williamsport, PA. 17701 U.S.A. Tel. 570 323 6181 Fax. 570 327 7101 www.lycoming.com SERVICE INSTRUCTION DATE: March 8, 2012 Service Instruction No. 1098H (Supersedes Service Instruction

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

Table 1d - FSA for All Returns, Females Tax Year

Table 1d - FSA for All Returns, Females Tax Year PR 10 Newfoundland and Labrador A0A 20,250 597,345 1,920 1,720 2,580 3,150 1,960 1,610 1,360 1,030 1,020 740 550 460 630 470 410 290 290 70 20 A0B 8,850 249,804 780 740 1,200 1,520 1,010 790 540 430 370

More information

SSR SSR SSR SSR

SSR SSR SSR SSR DMX 52 Page DMX52 decoder firing board module 20 VAC reference Input 2 3 4 The Thyristor Firing board is compatible withdmx52 control standard 4 DMX52 triggers 2 3 4 - +- +- +- + The can trigger control

More information

Red Spot BS Industrial fuse holders

Red Spot BS Industrial fuse holders Supersedes February 2017 BUSSMANN SERIES Product description Eaton s Bussmann series Red Spot British standard industrial fuse holders address many applications needs. Features They are fully shrouded

More information

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date: MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER 15-24 Date: 11-19-2015 SUBJECT: MODELS/ S/N AFFECTED: To ADVISE MOONEY OWNERS/OPERATORS of the LYCOMING Service Instruction

More information

MEDIUM VOLTAGE DIN Fuse-Links

MEDIUM VOLTAGE DIN Fuse-Links Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 12TDLEJ(amp) 12THLEJ(amp) 12TKLEJ(amp) 12TXLEJ(amp) 12TFMSJ(amp) Class of Operation: Back-up

More information

Miniature Fuses p. 226

Miniature Fuses p. 226 Fuses & Fusegear Miniature Fuses p. 226 Miniature fuses IEC Glass body GP003 p. 227 Miniature fuses IEC Ceramic body GP003 p. 228 Miniature fuses Glass body GP003 p. 229 to 230 Other Miniature fuses Miniature

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Circuit Protection Solutions Product Guide

Circuit Protection Solutions Product Guide Circuit Protection Solutions Product Guide Product Guide Low Voltage Fuses and Fusegear NH DIN Industrial fuse links and bases Conforms to IEC 60269 & VDE 0636 General purpose full range & Motor protection

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Inlet (1) Exhaust (3) Cylinder () 33 34 36 3 37 38 5 67 69

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up

More information

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI CFR Series Coils, Transformers OUTLINE Power inductors for preventing the diffusion of noises generated from power circuits and suppressing noise components coming through the power lines. ø8.7 ø11 max.

More information

Medium Voltage Controllable Fuse

Medium Voltage Controllable Fuse Medium Voltage Controllable Fuse SOLUTIONS GUIDE SOLUTIONS GUIDE Intelligent Fuse Technology Introducing the Next Generation of Medium Voltage Arc-Flash Protection Mersen s new Medium Voltage Controllable

More information

Switching. Overview. Contents

Switching. Overview. Contents Switching Overview Contents Loadbreak Switches............................................../2 - /4 Changeover Switches................................................./5 Switch Fuses......................................................./6

More information

MEDIUM VOLTAGE DIN Fuse-Links

MEDIUM VOLTAGE DIN Fuse-Links Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1

More information

690/700 Volt PSC Square Body

690/700 Volt PSC Square Body Mersen 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available in four different

More information

Overview. Contents. Overview

Overview. Contents. Overview 1/0 Overview 1 Contents Overview 3-pole Block Contactors and Motor Protection... 1/ 4-pole Block Contactors... 1/3 Contactors for Specific Applications... 1/4 Mini Contactors and Motor Protection... 1/

More information

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON Only for internal use Stars or starlets? Competitor overview switching devices sirius IN COMPARISON Who are the real stars? The comparison. Under ideal conditions, the human eye can make-out approximately

More information

PARAMOUNT HRC CARTRIDGE FUSELINKS & FUSE UNITS

PARAMOUNT HRC CARTRIDGE FUSELINKS & FUSE UNITS PARAMOUNT HRC CARTRIDGE FUSELINKS & FUSE UNITS The leading edge of HRC fuse technology Options to suit every application Compact 415V fuselinks NEW ferrule fuselinks New F type semi-conductor fuselinks

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

CUSTOMER GUIDE FUSE CATALOGUE

CUSTOMER GUIDE FUSE CATALOGUE CUSTOMER GUIDE FUSE CATALOGUE For a better, brighter service THE FUSE SPECIALIST SERVICE AT YOUR LOCAL BRANCH Electric Center branches stock an extensive range of fuses to suit your every need, local branches

More information

The Product Range. Technical Data

The Product Range. Technical Data The Product Range Section 3.1 - Basic Cylinder Bore sizes (mm): 10, 16, 25, 32, 40, 50 The basic cylinder series satisfies the support and guidance requirements of a great diversity of applications. Various

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Helio Protection.   Solar solutions designed by Ferraz Shawmut. Power generation & distribution. 1 Helio Protection Solar solutions designed by Ferraz Shawmut www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

Protistor size 120 gr 750VDC (IEC)

Protistor size 120 gr 750VDC (IEC) Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved DATE: May 19, 2000 (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved SUBJECT: MODELS AFFECTED: TIME OF COMPLIANCE: Approved Slick Magnetos on Textron Lycoming Engines See

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Push Button Units and Indicator Lights

Push Button Units and Indicator Lights 3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at

More information