1 CTBUH Technical Paper Subject: Paper Title: Author(s): Affiliation(s): Structural Engineering Control Effect of Hydraulic Dampers Installed in High-rise Building Observed during Earthquakes Shimizu, Kan Orui, Satoshi Kurino, Haruhiko Omika, Yukihiro Koshika, Norihide Kajima Corporation, Tokyo, Japan Publication Date: 8 Original Publication: CTBUH 8th World Congress, Dubai. March 3-5, 8. Paper Type:. Book chapter/part chapter. Journal paper 3. Conference proceeding 4. Unpublished conference paper 5. Magazine article 6. Unpublished Council on Tall Buildings and Urban Habitat/Author(s)

2 Control Effect of Hydraulic Dampers Installed in High-rise Building Observed during Earthquakes Kan Shimizu, Satoshi Orui, Haruhiko Kurino, Yukihiro Omika 3 and Norihide Koshika 4 Senior Research Engineer, Supervisory Research Engineer, 3 Standing Advisor, 4 General Manager, Kajima Corporation KI Building 6-5-3, Akasaka, Minato-ku, Tokyo, Japan kan-shimizu@kajima.com, orui@kajima.com, kurino@kajima.com, omika@kajima.com, koshika@kajima.com kan-shimizu@kajima.com orui@kajima.com Kan Shimizu Kan Shimizu received the M. S. degree in civil engineering from Waseda University, Tokyo, Japan in 997. He is currently a senior research engineer in Kobori Research Complex of Kajima Corporation. He has been involved with about twenty high rise-buildings in Japan, planning the structural control devises and conducting seismic response analyses. Haruhiko Kurino Haruhiko Kurino received the M. S. and D.Eng. degree in structural engineering from University of Tokyo, Tokyo, Japan in 99 and 4, respectively. He is currently a supervisory research engineer in Kobori Research Complex of Kajima Corporation. He has studied structural control algorithms and developed hydraulic control devices, including a semi-active oil damper which has been widely used in high-rise buildings in Japan. CTBUH 8th World Congress 8

3 Control Effect of Hydraulic Dampers Installed in High-rise Building Observed during Earthquakes Kan Shimizu, Satoshi Orui, Haruhiko Kurino, Yukihiro Omika 3 and Norihide Koshika 4 Senior Research Engineer, Supervisory Research Engineer, 3 Standing Advisor, 4 General Manager, Kajima Corporation KI Building 6-5-3, Akasaka, Minato-ku, Tokyo, Japan kan-shimizu@kajima.com, orui@kajima.com, kurino@kajima.com, omika@kajima.com, koshika@kajima.com Abstract This paper estimates the dynamic characteristic, especially damping, of an actual high-rise building with two kinds of oil dampers, conventional passive oil dampers and semi-active switching oil dampers, from records of the building s responses during large earthquakes. It also assesses the effect of the semi-active oil dampers by comparing the estimated damping with that predicted by a seismic design model. The building is located in Niigata prefecture, Japan, which has recently been subjected to three large earthquakes: the Mid Niigata prefecture Earthquake in 4, the Noto Hanto Earthquake in 7 and the Niigataken Chuetu-oki Earthquake in 7. During these earthquakes, valuable records were obtained of the responses of the building and behavior of the semi-active oil damper. From the records, equivalent damping ratios are estimated at 6.4% to 6.7% in the transverse direction in which the semi-active oil dampers are applied and 4.3% to 4.8% in the longitudinal direction in which the passive oil dampers are applied. The high damping property of the structural controlled building is also verified. The damping provided by the semi-active oil dampers is estimated at about 5.5%, which was about.7 times that predicted by a seismic design model with passive oil dampers. Thus, the effect of the semi-active oil dampers is also verified. Keywords: structural control, semi-active oil damper, damping, observed record, earthquake Introduction In the last two decades a lot of research and application has been carried out on structural control devices (Spencer, 3, etc.). Recently many high-rise buildings in Japan are being equipped with some kind of structural control device. However, there are few seismic response records from buildings equipped with these device. Therefore, their effects in actual buildings in actual earthquakes have been insufficiently verified. A high-rise building with two kinds of oil dampers, semi-active and passive, recently experienced three large earthquakes and valuable records of its response and the behavior of the semi-active oil dampers were obtained. This paper reports the high damping characteristics of this building and the effects of the semi-active oil dampers. Outline of high-rise building The building was constructed in 3, in Niigata prefecture. Figure shows its exterior. It is 4m high and has 3 floors above ground and one underground. The lower floors are used as offices and the upper floors are used as hotel, as shown in Figure. Columns are concrete-filled steel tubes and the beams are steel. Oil dampers are mainly designed to reduce building responses under severe earthquakes. However, uncomfortable transverse vibrations were expected during strong winds because of its slender shape. Therefore, the dampers in the transverse direction were upgraded to semi-active oil dampers, which also work for very small vibrations and absorb twice as much energy as conventional oil dampers. Figure. Exterior of the building ~9F ~8F ~F Semi-active Oil Damper Passive Oil Damper 5F 46.4m Figure 3. Plan Semi-active Oil Damper ~5F ~4F Figure. Section ~8F ~9F 3m Hotel Office CTBUH 8th World Congress 8

4 Figure 3 shows the distribution of the dampers. 7 semi-active oil dampers are set in the transverse direction and 4 passive oil dampers are set in the longitudinal direction. Outline of semi-active oil damper Figure 4 shows the semi-active oil damper installed in the building. One of the features of this damper is that the whole system which consists of a controller and an oil damper equipped with sensors is closed as shown in Figure 4. This makes it as easy to use this semi-active oil damper as it is use to a conventional oil damper. Table shows its specifications. Controller changed to a very small value (C min ) and the dashpot absorbs the energy accumulated in the spring. When the force decreases to point C, C(t) is changed to C max again and the damper continues this cycle. The force-displacement relation of a semi-active oil damper under this control law is shown in Figure 7. The force-displacement relation of a passive oil damper with an optimum damping coefficient is also shown in Figure 7. These areas show the energy absorption capacity of the damper. The semi-active oil damper can absorb twice as much energy as the passive oil damper. Brace Column Beam Brace, Damper Damper Damper Figure 5. Mechanical model of oil damper installed in a building F F F FB B B B Table. Specifications of semi-active oil damper Item Oil Damper Figure 4. Installed semi-active oil damper Maximum design force F max Relief force F R Maximum piston stroke Stiffness k d Size Power consumption Specification,5kN,3kN mm 5MN/m 37mm,435mm Approximately 5W Oil dampers are usually installed in the inter-story spaces of buildings with braces as shown in Figure 5. Their mechanical model is described as a Maxwell model. Under the constraint of the Maxwell model, a conventional passive oil damper with a linear damping coefficient behaves like a spring when the damping coefficient is too large and doesn t generate any force when it is too small. Therefore, there is an optimum damping coefficient that produces the maximum energy absorption capacity for the passive oil damper. On the other hand, the semi-active oil damper s control law maximizes the energy absorption capacity under the constraint of the Maxwell model by switching the damping coefficient, as described in Kurino et al. (3). Figure 6 show the behavior of the Maxwell model and its elements under this control law. The damping coefficient (C(t)) is usually kept large (C max ). When vibration starts C(t) is kept to C max from point A to B, so the dashpot doesn t move and the spring accumulates energy. At point B, at which the velocity changes direction, C(t) is F -F A Cm ax Cm ax D Semi-active oil damper Cm in Cm ax Cm in k C C C x xk A A Cm ax D D amaxwell model bspring element cdashpot element Figure 6. Behavior of semi-active oil damper k F k Cmax k Damper characteristics and performance have been verified through full-scale device tests (Kurino et al., 3), and forced vibration tests (Tagami et al.,, Shimizu et al., 4). It is now being applied or planned for more than buildings and this number will increase. Observed response during earthquake Acceleration sensors were set on the roof floor mainly to observe the building s response under strong winds such as typhoons. The 5 th floor semi-active oil damper s force and stroke were also observed to check its behavior. On October 3 4, the building was subjected to the Mid-Niigata Prefecture Earthquake whose magnitude was 6.8 and epicentral distance was about 73km. In order to estimate the dynamic characteristics of the building from records of after Cmin Cmin Cmax Passive oil damper with optimum C Figure 7. Force-displacement relation of dampers under harmonic excitation x CTBUH 8th World Congress 8

5 shocks, an acceleration sensor was quickly added to the first basement floor. Records of after shocks in November 8 were thus obtained. There were two more large earthquakes in 7. The first was the Noto Hanto Earthquake, whose magnitude was 6.9 and epicentral distance was about km. The next was the Niigataken Chuetu-oki Earthquake, whose magnitude was 6.8 and epicentral distance was 57 km. During this earthquake, the maximum damper force reached 64kN, which was the maximum force of this damper in an actual building. Acc.(cm/s ) Acc.(cm/s ) (a) Roof floor acceleration (Longitudinal direction) structural control device in an actual building are rare. Figure 8 shows the records during the Niigataken Chuetu-oki Earthquake. The force-displacement relation shown in Figure 8(e) shows the typical parallelogram shape produced by this control law. Table shows the maximum acceleration of the roof floor and the first basement floor and the maximum force of the semi-active oil damper. Figure 9 shows the location of the building and the epicenters. Table. Maximum acceleration of records Earthquake BF Long. (cm/s ) BF Tran. (cm/s ) RF Long. (cm/s ) RF Tran. (cm/s ) Mid Niigata (main) Mid Niigata (after) Force (kn) Noto Hanto Chuetu-oki (b) Roof floor acceleration (Transverse direction) Acc.(cm/s ) Building (c) First basement floor acceleration (Longitudinal direction) Acc.(cm/s ) (d) First basement floor acceleration (Transverse direction) (e) Force-stroke relation of 5 th floor semi-active oil damper Figure 8. Records of the Niigataken Chuetu-oki earthquake in 7 These records are very valuable because such large responses of a structural controlled building and a Figure 9. Location of building and epicenters Estimate of building s dynamic characteristics In this section, dynamic characteristics such as natural frequency and equivalent damping ratio are estimated. In particular, damping is discussed and the effect of dampers is verified. Only the first mode, which is the dominant vibration mode of the building, is considered. Before discussing damping during earthquakes, damping during microtremors is demonstrated, because the vibration level of microtremors is small enough to neglect the effect of dampers. Equivalent damping ratios of the building during microtremors were estimated by the Random Decrement (RD) technique (Tamura et al., 993). Time histories of free vibrations obtained by the RD technique are shown in Figure. Estimated damping ratios were.97% in the transverse direction and.% in the longitudinal direction. CTBUH 8th World Congress 8

6 Freq.(Hz) Freq.(Hz) Acc.(cm/s ) Dampig Ratio Damping Ratio RF Disp.(cm) (a) st mode natural frequency (Longitudinal direction) (a) Transverse direction Identified (b) Longitudinal direction Figure. Random decrement and free vibration decay response of microtremer Observed record Figure. Comparison between the identified record and observed record (The Niigataken Chuetu-oki earthquake in 7) RF Disp.(cm) (b) st mode natural frequency (transverse direction) 3 RF Disp.(cm) (c) st mode damping ratio (Longitudinal direcrion) 4 h=.97% h=.% RF Disp.(cm) (d) st mode damping ratio (transverse direcrion) Figure. Estimated dynamic characteristics Microtremor Microtremor On the basis of damping of conventional steel structures shown in Satake, 3, these results were inferred as damping without dampers. Next, the dynamic characteristics under earthquake vibrations are estimated. First, the time history of the roof floor acceleration is filtered to extract the first vibration mode. Then a Single Degree of Freedom (SDOF) system that makes the mean-square error the smallest is identified as shown in the following equation x( t) 4hfx ( t) x( t) X BF ( t) T () ( X ( t) x( t)) dt min RF RF where x(t) is the response of a SDOF system, h is the damping ratio of a SDOF system, f is the natural frequency of a SDOF system, X B F is the filtered acceleration record at the first basement floor, T is the duration of the earthquake, X RF is the filtered acceleration record at the roof floor, and RF is a first mode participation function at the roof floor, for which the participation factor of the seismic design model shown in Figure 4 is used. As a result, the natural period and the damping ratio of the SDOF system are identified as those of the building. In Figure, the dotted line shows the filtered acceleration record at the roof floor, and the full line shows the identified time history of the record of the Niigataken Chuetu-oki Earthquake in 7. These lines show a significant match. Figure shows the identified natural frequencies and damping ratios of each record. The amplitudes are the maximum displacement of the roof floor. Identified damping ratios are from 6.4% to 6.7% in the transverse direction and from 4.3% to 4.8% in the longitudinal direction. Compared with the microtremor case shown by the full line in Figure (c), (d), the high damping characteristic of the building with oil dampers are verified. We also used another method to check the reliability of the identified dynamic characteristics. The previous method depends on a physical quantity and uses an equation of motion but this method doesn t depend on a physical quantity. First, the transmissibility is identified as single-input-single-output ARX model: input is filtered acceleration at the first basement floor and output is filtered acceleration at the roof floor. Then the natural frequency and corresponding damping ratio are calculated from the pole of the identified ARX model (AFAK, 99). The identified results are 6.3% to 7.3% in the transverse direction and 4.4% to 5.5% in the longitudinal direction. The difference between the two methods is less than 5%. Here, the observed effect of the dampers is compared with that expected by the seismic design model. Figure 3 shows the seismic design model, in which each column and beam is modeled as a beam element. Bending deformation, shear deformation and axial deformation are considered at columns and bending and shear CTBUH 8th World Congress 8

7 deformations are considered at beams. Panel elements at which only shear deformation is considered were set at each column/beam connection. Oil dampers are modeled as a Maxwell model, described in Figure 5. Figure 4 shows the mode shape of each direction. dampers is almost the same as that predicted by the seismic design model and the damping added by the semi-active oil dampers are almost.7 times that predicted by the seismic design model with passive oil dampers. Therefore, the effect of semi-active oil dampers is clearly verified. Floor 3 Figure 3. Seisimic design model : st mode : nd mode :3 rd mode Floor 3 Additional discussion (Wind case) This section demonstrates the effect of the semi-active oil dampers during strong winds. In 4, typhoons struck Japan. This was a record since the Japan Meteorological Agency started to take statistics in 95. One of them, Typhoon 6, had a maximum daily wind velocity of 9.5m/s, which was recorded at Niigata Local Meteorological Observatory. This was the maximum daily wind velocity in 4 in Niigata, and it continued for about hours. Damping in the transverse direction during this typhoon was also estimated by an RD technique as 5.3%. Figure 5 shows the force-stroke relation of the 5 th floor semi-active oil damper during the typhoon. It also shows a typical parallelogram shape from a very small stroke, under.5mm. Next the without damper time history is estimated. The absolute acceleration response, x w, without semi-active oil damper is calculated by equation () considering only the first mode. x w H H s s ( if ) H ( if ) x w ( if ) Hw( if ) s f / f hs f / f i f / f h f / f i where H s (if) is the st mode transfer function with semi-active oil damper, H w (if) is the st mode transfer function without damper, x s is the observed record, f is the st natural frequency, h s is the st equivalent damping ratio with semi-active oil damper, and h w is the st equivalent damping ratio without damper. w () (a) Longitudinal direction (b) Transverse direction Figure 4. Mode shape (Participation function) Complex eigen value analysis was conducted to estimate damping added by passive dampers. Damping factors of dampers were set to 5MNs/m. To accurately estimate the effect of dampers, damping of the structure isn t set. The complex eigen value analysis yielded values of 3.% for each direction. By subtracting damping estimated during microtremors from damping estimated during earthquakes, the damping added by the dampers in an actual building is obtained. The values thus obtained were 5.4% to 5.7% in the transverse direction and 3.% to 3.7% in the longitudinal direction. Comparison of the results verified that the damping added by the passive Figure 5. Force-stroke relation of 5 th floor semi-active oil damper under typhoon Results estimated by the RD technique were used as parameters:.3hz for f,.53 for h s, and.97 for h w. Figure 6 compares the top floor acceleration time history of Without damper estimated by equation () against the observed acceleration record. Without CTBUH 8th World Congress 8

8 semi-active oil damper, the maximum response of the building would double and uncomfortable vibration would continue for a long time. AFAK, E. (99). Adaptive Modeling, Identification, and Control of Dynamic Structural Systems : Theory. Journal of Structural Engineering, ASCE, Vol.5, No., pp , November 99 (a) With Damper (Observed) (b) Without Damper (Simulated) Figure 6. Roof floor acceleration time history (transverse direction) Conclusion Three large earthquake records were obtained from a high-rise building equipped with semi-active oil dampers in the transverse direction and conventional passive oil dampers in the longitudinal direction. Estimated damping verified the high damping property of the building with oil dampers. Equivalent damping ratios were from 6.4% to 6.7% in the transverse direction and from 4.3% to 4.8% in the longitudinal direction. The effect of the dampers was also discussed with reference to a seismic design model. By comparing the damping ratio added by the dampers estimated from the earthquake records with that estimated from the seismic design model with passive oil dampers, it was verified that the passive oil dampers showed almost the same results as expected, and the semi-active oil dampers showed high performance in adding damping, which was about.7 times as large as that expected by a passive oil damper. References SPENCER, Jr. B. F., and NAGARAJAIAH, S. (3). State of the Art of Structural Control. Journal of Structural Engineering, ASCE, Vol. 9 No.7, pp , July 3 KURINO, H., TAGAMI, J., SHIMIZU, K., and KOBORI, T. (3). Switching Oil Damper with Built-in Controller for Structural Control. Journal of Structural Engineering, ASCE, Vol. 9 No.7 pp TAGAMI, J., KOSHIDA, H., KURINO, H., SUGIYAMA, T., SUWA, M., and MORI, F. (). Forced Vibration Test of an -story Building with Semi-active Switching Oil Damper. Proceedings of the 3rd World Conference on Structural Control, Como, Italy. April 7-,. Vol. pp.75-8 SHIMIZU, K., YAMADA, T., TAGAMI, J., and KURINO, H. (4). Vibration Tests of Actual Buildings with Semi-active Switching Oil Damper. Proceedings of the 3th World Conference of Earthquake Engineering, Vancouver, B.C., Canada, August -6, 4. Paper No. 53 TAMURA, Y., SASAKI, A., and TSUKAGOSHI, H. (993). Evaluation of Damping Ratios of Randomly Excited Buildings Using the Random Decrement Technique. Journal of Struct. Constr. Engng, AIJ; 454 pp. 9-38, in Japanese SATAKE, N., SUDA, K., ARAKAWA, T., SASAKI, A., and TAMURA, Y. (3). Damping Evaluation Using Full-Scale Data of Building in Japan. Journal of Structural Engineering, ASCE, Vol. 9 No.4, pp , April 3 CTBUH 8th World Congress 8

CONTROL EFFECT OF SEMI-ACTIVE SWITCHING OIL DAMPER INSTALLED IN ACTUAL HIGH-RISE BUILDING DURING LARGE EARTHQUAKES

CONTROL EFFECT OF SEMI-ACTIVE SWITCHING OIL DAMPER INSTALLED IN ACTUAL HIGH-RISE BUILDING DURING LARGE EARTHQUAKES October 2-7, 28, Beijing, China CONTROL EECT O SEMI-ACTIVE SWITCHING OIL DAMPER INSTALLED IN ACTUAL HIGH-RISE BUILDING DURING LARGE EARTHQUAKES ABSTRACT : Satoshi Orui, Haruhiko Kurino and Kan Shimizu

More information

Damping Ratio Estimation of an Existing 8-story Building Considering Soil-Structure Interaction Using Strong Motion Observation Data.

Damping Ratio Estimation of an Existing 8-story Building Considering Soil-Structure Interaction Using Strong Motion Observation Data. Damping Ratio Estimation of an Existing -story Building Considering Soil-Structure Interaction Using Strong Motion Observation Data by Koichi Morita ABSTRACT In this study, damping ratio of an exiting

More information

Seismic-upgrading of Existing Stacks of Nuclear Power Station using Structural Control Oil Dampers

Seismic-upgrading of Existing Stacks of Nuclear Power Station using Structural Control Oil Dampers October 12-17, 28, Beijing, China ABSTRACT : Seismic-upgrading of Existing Stacks of Nuclear Power Station using Structural Control Oil Dampers Ryu Shimamoto 1, Fukashi Mori 2, Tomonori Kitaori 2, Satoru

More information

Experimental verification of passively variable oil damper applied to seismically isolated houses for response reduction

Experimental verification of passively variable oil damper applied to seismically isolated houses for response reduction Experimental verification of passively variable oil damper applied to seismily isolated houses for response reduction M. Iiba Building Research Institute, Tsukuba, Japan T. Hanai & T. Minagawa Ebisu Building

More information

Dynamic tests of SRIM fluid viscous dampers

Dynamic tests of SRIM fluid viscous dampers Dynamic tests of SRIM fluid viscous dampers D. FENG & Y. SASAKI Fujita Corp., Tokyo, Japan. N. YAMAZAKI & M. ISHIYAMA Nippon Chuzo Co., Ltd., Kawasaki, Japan W. ZHU Shanghai Research Institute of Materials,

More information

JSSI MANUAL FOR BUILDING PASSIVE CONTROL TECHNOLOGY PART-10 TIME-HISTORY ANALYSIS MODEL FOR NONLINEAR OIL DAMPERS

JSSI MANUAL FOR BUILDING PASSIVE CONTROL TECHNOLOGY PART-10 TIME-HISTORY ANALYSIS MODEL FOR NONLINEAR OIL DAMPERS 3 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August -6, 4 Paper No. 83 JSSI MANUAL FOR BUILDING PASSIVE CONTROL TECHNOLOGY PART- TIME-HISTORY ANALYSIS MODEL FOR NONLINEAR OIL

More information

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle The 2012 World Congress on Advances in Civil, Environmental, and Materials Research (ACEM 12) Seoul, Korea, August 26-30, 2012 Oscillator Experiment of Simple Girder Bridge coupled with Vehicle Mitsuo

More information

RHOMBUS MECHANISM WITH FLUID DAMPER

RHOMBUS MECHANISM WITH FLUID DAMPER 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 4 Paper No. 11 RHOMBUS MECHANISM WITH FLUID DAMPER Deh-Shiu Hsu 1, Ming-Che Hsu, and Yung-Feng Lee 3 ABSTRACT Structural

More information

Abstract In this paper, we developed a lateral damper to improve the running safety of railway vehicles

Abstract In this paper, we developed a lateral damper to improve the running safety of railway vehicles Improvement of Running Safety of Railway Vehicles against an Earthquake Kohei Iida, Mitsugi Suzuki, Takefumi Miyamoto, Yukio Nishiyama, Daichi Nakajima Railway Technical Research Institute, Tokyo, JAPAN

More information

A DESIGN OF ADVANCED BASE-ISOLATION SYSTEM FOR ASYMMETRICAL BUILDING

A DESIGN OF ADVANCED BASE-ISOLATION SYSTEM FOR ASYMMETRICAL BUILDING - A DESIGN OF ADVANCED BASE-ISOLATION SYSTEM FOR ASYMMETRICAL BUILDING oji TSUCHIMOTO, Yoshikazu ITAGAA, azuo YOSHIDA Yozo SHINOZAI, Ichiro NAGASHIMA Yoichi SANUI, Hiroyasu OMATSU, Takahide OBAYASHI Design

More information

Seismic Capacity Test of Overhead Crane under Horizontal and Vertical Excitation - Element Model Test Results on Nonlinear Response Behavior-

Seismic Capacity Test of Overhead Crane under Horizontal and Vertical Excitation - Element Model Test Results on Nonlinear Response Behavior- 2th International Conference on Structural Mechanics in Reactor Technology (SMiRT 2) Espoo, Finland, August 9-14, 29 SMiRT 2-Division, Paper Seismic Capacity Test of Overhead Crane under Horizontal and

More information

Optimization of Scissor-jack-Damper s Parameters and Performance under the Constrain of Human Comfort

Optimization of Scissor-jack-Damper s Parameters and Performance under the Constrain of Human Comfort Optimization of Scissor-jack-Damper s Parameters and Performance under the Constrain of Human Comfort *Xin ZHAO 1) and Zhuang MA 2) 1) Tongji Architectural Design(Group) Co.,Ltd.,Shanghai,China 2) Department

More information

Effects of Container Size, Stroke and Frequency on Damping Properties of a Damper Using a Steel Particle Assemblage

Effects of Container Size, Stroke and Frequency on Damping Properties of a Damper Using a Steel Particle Assemblage Advanced Experimental Mechanics, Vol.1 (2016), 105-110 Copyright C 2016 JSEM Effects of Container Size, Stroke and Frequency on Damping Properties of a Damper Using a Steel Particle Assemblage Yasushi

More information

Design of Damping Base and Dynamic Analysis of Whole Vehicle Transportation based on Filtered White-Noise GongXue Zhang1,a and Ning Chen2,b,*

Design of Damping Base and Dynamic Analysis of Whole Vehicle Transportation based on Filtered White-Noise GongXue Zhang1,a and Ning Chen2,b,* Advances in Engineering Research (AER), volume 07 Global Conference on Mechanics and Civil Engineering (GCMCE 07) Design of Damping Base and Dynamic Analysis of Whole Vehicle Transportation based on Filtered

More information

Dynamic response of a vehicle model with six degrees-of-freedom under seismic motion

Dynamic response of a vehicle model with six degrees-of-freedom under seismic motion Structural Safety and Reliability, Corotis et al. (eds), 001 Swets & Zeitlinger, ISBN 90 5809 197 X Dynamic response of a vehicle model with six degrees-of-freedom under seismic motion Yoshihisa Maruyama

More information

CHAPTER 4: EXPERIMENTAL WORK 4-1

CHAPTER 4: EXPERIMENTAL WORK 4-1 CHAPTER 4: EXPERIMENTAL WORK 4-1 EXPERIMENTAL WORK 4.1 Preamble 4-2 4.2 Test setup 4-2 4.2.1 Experimental setup 4-2 4.2.2 Instrumentation, control and data acquisition 4-4 4.3 Hydro-pneumatic spring characterisation

More information

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics Tanmay P. Dobhada Tushar S. Dhaspatil Prof. S S Hirmukhe Mauli P. Khapale Abstract: A shock absorber is

More information

Clamping Force Effects on the Behaviour of Asymmetrical Friction Connections (AFC)

Clamping Force Effects on the Behaviour of Asymmetrical Friction Connections (AFC) Clamping Force Effects on the Behaviour of Asymmetrical Friction Connections (AFC) J. Chanchí Golondrino University of Canterbury, New Zealand National University of Colombia, Colombia G.A. MacRae, J.G.

More information

Relevant friction effects on walking machines

Relevant friction effects on walking machines Relevant friction effects on walking machines Elena Garcia and Pablo Gonzalez-de-Santos Industrial Automation Institute (CSIC) 28500 Madrid, Spain email: egarcia@iai.csic.es Key words: Legged robots, friction

More information

Comparison Of Multibody Dynamic Analysis Of Double Wishbone Suspension Using Simmechanics And FEA Approach

Comparison Of Multibody Dynamic Analysis Of Double Wishbone Suspension Using Simmechanics And FEA Approach International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 232-9364, ISSN (Print): 232-9356 Volume 2 Issue 4 ǁ April. 214 ǁ PP.31-37 Comparison Of Multibody Dynamic Analysis Of

More information

Fig.1 Sky-hook damper

Fig.1 Sky-hook damper 1. Introduction To improve the ride comfort of the Maglev train, control techniques are important. Three control techniques were introduced into the Yamanashi Maglev Test Line vehicle. One method uses

More information

Testing Of Fluid Viscous Damper

Testing Of Fluid Viscous Damper Testing Of Fluid Viscous Damper Feng Qian & Sunwei Ding, Jingjing Song Shanghai Research Institute of Materials, China Dr. Chien-Chih Chen US.VF Corp, Omni Device, China SUMMARY: The Fluid Viscous Damper

More information

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics Yasser Abdel Mohsen, Ashraf Sharara, Basiouny Elsouhily, Hassan Elgamal Mechanical Engineering

More information

ISSN: SIMULATION AND ANALYSIS OF PASSIVE SUSPENSION SYSTEM FOR DIFFERENT ROAD PROFILES WITH VARIABLE DAMPING AND STIFFNESS PARAMETERS S.

ISSN: SIMULATION AND ANALYSIS OF PASSIVE SUSPENSION SYSTEM FOR DIFFERENT ROAD PROFILES WITH VARIABLE DAMPING AND STIFFNESS PARAMETERS S. Journal of Chemical and Pharmaceutical Sciences www.jchps.com ISSN: 974-2115 SIMULATION AND ANALYSIS OF PASSIVE SUSPENSION SYSTEM FOR DIFFERENT ROAD PROFILES WITH VARIABLE DAMPING AND STIFFNESS PARAMETERS

More information

Comparison between Optimized Passive Vehicle Suspension System and Semi Active Fuzzy Logic Controlled Suspension System Regarding Ride and Handling

Comparison between Optimized Passive Vehicle Suspension System and Semi Active Fuzzy Logic Controlled Suspension System Regarding Ride and Handling Comparison between Optimized Passive Vehicle Suspension System and Semi Active Fuzzy Logic Controlled Suspension System Regarding Ride and Handling Mehrdad N. Khajavi, and Vahid Abdollahi Abstract The

More information

Optimization of Seat Displacement and Settling Time of Quarter Car Model Vehicle Dynamic System Subjected to Speed Bump

Optimization of Seat Displacement and Settling Time of Quarter Car Model Vehicle Dynamic System Subjected to Speed Bump Research Article International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347-5161 2014 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Optimization

More information

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online): 2321-0613 Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4

More information

Comparing PID and Fuzzy Logic Control a Quarter Car Suspension System

Comparing PID and Fuzzy Logic Control a Quarter Car Suspension System Nemat Changizi, Modjtaba Rouhani/ TJMCS Vol.2 No.3 (211) 559-564 The Journal of Mathematics and Computer Science Available online at http://www.tjmcs.com The Journal of Mathematics and Computer Science

More information

A Fundamental Study Concerning the Proper Performance of Lift Buffers in Revised JIS A 4306

A Fundamental Study Concerning the Proper Performance of Lift Buffers in Revised JIS A 4306 A Fundamental Study Concerning the Proper Performance of Lift Buffers in Revised JIS A 4306 Osamu Furuya 1, Naoki Fujiwara 2 and Satoshi Fujita 3 1 Associate Professor, Division of Electronics and Mechanical

More information

Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design

Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design Journal of Physics: Conference Series PAPER OPEN ACCESS Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design To cite this article: Jeffrey Too Chuan TAN et al 6 J. Phys.: Conf.

More information

Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model

Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model The interaction between a vehicle and the road is a very complicated dynamic process, which involves many fields such as vehicle

More information

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis Akira Aikawa *, Fumihiro Urakawa *, Kazuhisa Abe **, Akira Namura * * Railway Technical Research

More information

Modeling of 17-DOF Tractor Semi- Trailer Vehicle

Modeling of 17-DOF Tractor Semi- Trailer Vehicle ISSN 2395-1621 Modeling of 17-DOF Tractor Semi- Trailer Vehicle # S. B. Walhekar, #2 D. H. Burande 1 sumitwalhekar@gmail.com 2 dhburande.scoe@sinhgad.edu #12 Mechanical Engineering Department, S.P. Pune

More information

Structure Parameters Optimization Analysis of Hydraulic Hammer System *

Structure Parameters Optimization Analysis of Hydraulic Hammer System * Modern Mechanical Engineering, 2012, 2, 137-142 http://dx.doi.org/10.4236/mme.2012.24018 Published Online November 2012 (http://www.scirp.org/journal/mme) Structure Parameters Optimization Analysis of

More information

PIPE WHIP RESTRAINTS - PROTECTION FOR SAFETY RELATED EQUIPMENT OF WWER NUCLEAR POWER PLANTS

PIPE WHIP RESTRAINTS - PROTECTION FOR SAFETY RELATED EQUIPMENT OF WWER NUCLEAR POWER PLANTS IAEA-CN-155-009P PIPE WHIP RESTRAINTS - PROTECTION FOR SAFETY RELATED EQUIPMENT OF WWER NUCLEAR POWER PLANTS Z. Plocek a, V. Kanický b, P. Havlík c, V. Salajka c, J. Novotný c, P. Štěpánek c a The Dukovany

More information

Development of Rattle Noise Analysis Technology for Column Type Electric Power Steering Systems

Development of Rattle Noise Analysis Technology for Column Type Electric Power Steering Systems TECHNICAL REPORT Development of Rattle Noise Analysis Technology for Column Type Electric Power Steering Systems S. NISHIMURA S. ABE The backlash adjustment mechanism for reduction gears adopted in electric

More information

OPTIMIZATION STUDIES OF ENGINE FRICTION EUROPEAN GT CONFERENCE FRANKFURT/MAIN, OCTOBER 8TH, 2018

OPTIMIZATION STUDIES OF ENGINE FRICTION EUROPEAN GT CONFERENCE FRANKFURT/MAIN, OCTOBER 8TH, 2018 OPTIMIZATION STUDIES OF ENGINE FRICTION EUROPEAN GT CONFERENCE FRANKFURT/MAIN, OCTOBER 8TH, 2018 M.Sc. Oleg Krecker, PhD candidate, BMW B.Eng. Christoph Hiltner, Master s student, Affiliation BMW AGENDA

More information

Simulation of Voltage Stability Analysis in Induction Machine

Simulation of Voltage Stability Analysis in Induction Machine International Journal of Electronic and Electrical Engineering. ISSN 0974-2174 Volume 6, Number 1 (2013), pp. 1-12 International Research Publication House http://www.irphouse.com Simulation of Voltage

More information

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.6 ROLLING NOISE FROM

More information

MAGNETORHEOLOGICAL FLUID DAMPER WITH EXTERNAL MAGNETIC CIRCUIT. Alexandru Boltosi, Adrian Chiriac, Liviu Bereteu, Ramona Nagy, Voichiţa Hule

MAGNETORHEOLOGICAL FLUID DAMPER WITH EXTERNAL MAGNETIC CIRCUIT. Alexandru Boltosi, Adrian Chiriac, Liviu Bereteu, Ramona Nagy, Voichiţa Hule Analele Universităţii de Vest din Timişoara Vol. LII, 2008 Seria Fizică MAGNETORHEOLOGICAL FLUID DAMPER WITH EXTERNAL MAGNETIC CIRCUIT Alexandru Boltosi, Adrian Chiriac, Liviu Bereteu, Ramona Nagy, Voichiţa

More information

Control and Simulation of Semi-Active Suspension System using PID Controller for Automobiles under LABVIEW Simulink

Control and Simulation of Semi-Active Suspension System using PID Controller for Automobiles under LABVIEW Simulink International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2017 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Control

More information

Influence of Parameter Variations on System Identification of Full Car Model

Influence of Parameter Variations on System Identification of Full Car Model Influence of Parameter Variations on System Identification of Full Car Model Fengchun Sun, an Cui Abstract The car model is used extensively in the system identification of a vehicle suspension system

More information

Experimental Evaluation of New Magnetic Movement Converter for Linear Oscillatory Actuator

Experimental Evaluation of New Magnetic Movement Converter for Linear Oscillatory Actuator APAEM14 Journal of the Japan ociety of Applied Electromagnetics and Mechanics Vol.23, o.3 (215) Regular Paper Experimental Evaluation of ew Magnetic Movement Converter for Linear Oscillatory Actuator Fumiya

More information

Gauge Face Wear Caused with Vehicle/Track Interaction

Gauge Face Wear Caused with Vehicle/Track Interaction Gauge Face Wear Caused with Vehicle/Track Interaction Makoto ISHIDA*, Mitsunobu TAKIKAWA, Ying JIN Railway Technical Research Institute 2-8-38 Hikari-cho, Kokubunji-shi, Tokyo 185-8540, Japan Tel: +81-42-573-7291,

More information

HYSTERISIS CHARACTERISTIC OF LEAD PILLAR DAMPER

HYSTERISIS CHARACTERISTIC OF LEAD PILLAR DAMPER 33 HYSTERISIS CHARACTERISTIC OF LEAD PILLAR DAMPER Shinji ARAMAKI 1, Kiyoshi UNO, Yoshito MAEDA 3 And Kathuhiko NOYORI 4 SUMMARY The existed damper usually has rectangular hysterisis when attenuation stiffness

More information

Semi-Active Suspension for an Automobile

Semi-Active Suspension for an Automobile Semi-Active Suspension for an Automobile Pavan Kumar.G 1 Mechanical Engineering PESIT Bangalore, India M. Sambasiva Rao 2 Mechanical Engineering PESIT Bangalore, India Abstract Handling characteristics

More information

Development of analytical process to reduce side load in strut-type suspension

Development of analytical process to reduce side load in strut-type suspension Journal of Mechanical Science and Technology 24 (21) 351~356 www.springerlink.com/content/1738-494x DOI 1.7/s1226-9-113-z Development of analytical process to reduce side load in strut-type suspension

More information

EFFECTIVE SOLUTIONS FOR SHOCK AND VIBRATION CONTROL

EFFECTIVE SOLUTIONS FOR SHOCK AND VIBRATION CONTROL EFFECTIVE SOLUTIONS FOR SHOCK AND VIBRATION CONTROL Part 1 Alan Klembczyk TAYLOR DEVICES, INC. North Tonawanda, NY Part 2 Herb LeKuch Shocktech / 901D Monsey, NY SAVIAC Tutorial 2009 Part 1 OUTLINE Introduction

More information

Assessing Pavement Rolling Resistance by FWD Time History Evaluation

Assessing Pavement Rolling Resistance by FWD Time History Evaluation Assessing Pavement Rolling Resistance by FWD Time History Evaluation C.A. Lenngren Lund University 2014 ERPUG Conference 24 October 2014 Brussels 20Nm 6 Nm 2 Nm Background: Rolling Deflectometer Tests

More information

Modeling, Design and Simulation of Active Suspension System Frequency Response Controller using Automated Tuning Technique

Modeling, Design and Simulation of Active Suspension System Frequency Response Controller using Automated Tuning Technique Modeling, Design and Simulation of Active Suspension System Frequency Response Controller using Automated Tuning Technique Omorodion Ikponwosa Ignatius Obinabo C.E Evbogbai M.J.E. Abstract Car suspension

More information

AERODYNAMIC STABILITY OF A SUPER LONG-SPAN BRIDGE WITH SLOTTED BOX GIRDER

AERODYNAMIC STABILITY OF A SUPER LONG-SPAN BRIDGE WITH SLOTTED BOX GIRDER AERODYNAMIC STABILITY OF A SUPER LONG-SPAN BRIDGE WITH SLOTTED BOX GIRDER by Hiroshi SATO ), Nobuyuki HIRAHARA 2), Koichiro FUMOTO 3), Shigeru HIRANO 4) and Shigeki KUSUHARA 5) ABSTRACT Aerodynamic stability

More information

A CONTRIBUTION TO PASSIVE SHOCK ABSORBER FORCE INVESTIGATION

A CONTRIBUTION TO PASSIVE SHOCK ABSORBER FORCE INVESTIGATION Original Scientific Paper doi:10.5937/jaes12-5445 Paper number: 12(2014)3, 295, 217-226 A CONTRIBUTION TO PASSIVE SHOCK ABSORBER FORCE INVESTIGATION Dr Miroslav Demić* Faculty of Engineering Sciences,

More information

SHM-based condition assessment of expansion Joints in suspension Bridges Zhang Yufeng 1), *Sun Zhen 2) and Peng Jiayi 3)

SHM-based condition assessment of expansion Joints in suspension Bridges Zhang Yufeng 1), *Sun Zhen 2) and Peng Jiayi 3) SHM-based condition assessment of expansion Joints in suspension Bridges Zhang Yufeng 1), *Sun Zhen 2) and Peng Jiayi 3) 1), 2) 3) Key Laboratory of Large-span Bridge Health Inspection & Diagnosis Technology

More information

Development of Oil Damper System for Seismically Isolated Structures with Lock Mechanism

Development of Oil Damper System for Seismically Isolated Structures with Lock Mechanism KY TECHNICL REVIEW No. 54 PR. 2017 Product Introduction Development of Oil Damper System for Seismically Isolated Structures with Lock Mechanism ITO Yoshihiro, SUZUKI Takio 1 Introduction When we experience

More information

Mathematical Modelling and Simulation Of Semi- Active Suspension System For An 8 8 Armoured Wheeled Vehicle With 11 DOF

Mathematical Modelling and Simulation Of Semi- Active Suspension System For An 8 8 Armoured Wheeled Vehicle With 11 DOF Mathematical Modelling and Simulation Of Semi- Active Suspension System For An 8 8 Armoured Wheeled Vehicle With 11 DOF Sujithkumar M Sc C, V V Jagirdar Sc D and MW Trikande Sc G VRDE, Ahmednagar Maharashtra-414006,

More information

Dynamic Response of High-Speed-Moving Vehicle Subjected to Seismic Excitation Considering Passengers' Dynamics

Dynamic Response of High-Speed-Moving Vehicle Subjected to Seismic Excitation Considering Passengers' Dynamics Dynamic Response of High-Speed-Moving Vehicle Subjected to Seismic Excitation Considering Passengers' Dynamics A. Shintani, T. Ito, C. Nakagawa & Y. Iwasaki Osaka Prefecture University, Japan SUMMARY:

More information

Design of a Gentle Damping System for a Weak Wooden House Takahito Adachi, Kenji Takahara

Design of a Gentle Damping System for a Weak Wooden House Takahito Adachi, Kenji Takahara Design of a Gentle Damping System for a Weak Wooden House Takahito Adachi, Kenji Takahara Abstract This paper proposes a control system to reduce vibrations in existing wooden houses that are insufficient

More information

B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY

B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY 1 B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY (Mechanical Engineering) Time: 3 hours Max. Marks: 70 Answer any FIVE questions All questions

More information

Behaviors of Flag-Shaped Dampers Using Combination of Magnetic Friction and Rubber Springs

Behaviors of Flag-Shaped Dampers Using Combination of Magnetic Friction and Rubber Springs Behaviors of Flag-Shaped Dampers Using Combination of Magnetic Friction and Rubber Springs Eunsoo Choi, Gyuchan Choi, Yunjeong Son, Seungmin Gin Speaker : Yunjeong Son Master s Course, 215.11.17 2 Contents

More information

Aspects Concerning Modeling and Simulation of a Car Suspension with Multi-Body Dynamics and Finite Element Analysis Software Packages

Aspects Concerning Modeling and Simulation of a Car Suspension with Multi-Body Dynamics and Finite Element Analysis Software Packages Aspects Concerning Modeling and Simulation of a Car Suspension with Multi-Body Dynamics and Finite Element Analysis Software Packages Andrei Dumitru, Ion Preda, and Gheorghe Mogan Transilvania University

More information

CHAPTER 1 BALANCING BALANCING OF ROTATING MASSES

CHAPTER 1 BALANCING BALANCING OF ROTATING MASSES CHAPTER 1 BALANCING Dynamics of Machinery ( 2161901) 1. Attempt the following questions. I. Need of balancing II. Primary unbalanced force in reciprocating engine. III. Explain clearly the terms static

More information

DYNAMIC TESTS ON A CONCRETE SLAB WITH A TUNED MASS DAMPER

DYNAMIC TESTS ON A CONCRETE SLAB WITH A TUNED MASS DAMPER MATEC Web of Conferences, 6 ( 15) DOI: 1.151/ matecconf/ 15 6 C Owned by the authors, published by EDP Sciences, 15 DYNAMIC TESTS ON A CONCRETE SLAB WITH A TUNED MASS DAMPER Jorge Eliécer Campuzano Carmona

More information

Simulation and Analysis of Vehicle Suspension System for Different Road Profile

Simulation and Analysis of Vehicle Suspension System for Different Road Profile Simulation and Analysis of Vehicle Suspension System for Different Road Profile P.Senthil kumar 1 K.Sivakumar 2 R.Kalidas 3 1 Assistant professor, 2 Professor & Head, 3 Student Department of Mechanical

More information

Design and Analysis of Hydrostatic Bearing Slide Used Linear Motor Direct-drive. Guoan Hou 1, a, Tao Sun 1,b

Design and Analysis of Hydrostatic Bearing Slide Used Linear Motor Direct-drive. Guoan Hou 1, a, Tao Sun 1,b Advanced Materials Research Vols. 211-212 (2011) pp 666-670 Online available since 2011/Feb/21 at www.scientific.net (2011) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/amr.211-212.666

More information

MARINE FOUR-STROKE DIESEL ENGINE CRANKSHAFT MAIN BEARING OIL FILM LUBRICATION CHARACTERISTIC ANALYSIS

MARINE FOUR-STROKE DIESEL ENGINE CRANKSHAFT MAIN BEARING OIL FILM LUBRICATION CHARACTERISTIC ANALYSIS POLISH MARITIME RESEARCH Special Issue 2018 S2 (98) 2018 Vol. 25; pp. 30-34 10.2478/pomr-2018-0070 MARINE FOUR-STROKE DIESEL ENGINE CRANKSHAFT MAIN BEARING OIL FILM LUBRICATION CHARACTERISTIC ANALYSIS

More information

A study on the vibration analysis of a maglev vehicle A theoretical investigation of the effect of magnetic damping on a vibration control system

A study on the vibration analysis of a maglev vehicle A theoretical investigation of the effect of magnetic damping on a vibration control system International Journal of Applied Electromagnetics and Mechanics 13 (2001/2002) 79 83 79 IOS Press A study on the vibration analysis of a maglev vehicle A theoretical investigation of the effect of magnetic

More information

Design and Analysis of Damper Systems for Circuit Breaker

Design and Analysis of Damper Systems for Circuit Breaker ISSN 2395-1621 Design and Analysis of Systems for Circuit Breaker #1 Bhavya Ramakrishnan, #2 Pramod Yadav, #3 Dhananjay R. Panchagade 1 bhavyu.r@gmail.com 2 pramod.yadav@schneider-electric.com 3 panchagade@gmail.com

More information

Modeling and Vibration Analysis of a Drum type Washing Machine

Modeling and Vibration Analysis of a Drum type Washing Machine Modeling and Vibration Analysis of a Drum type Washing Machine Takayuki KOIZUMI, Nobutaka TSUJIUCHI, Yutaka NISHIMURA Department of Engineering, Doshisha University, 1-3, Tataramiyakodani, Kyotanabe, Kyoto,

More information

ISCORMA-3, Cleveland, Ohio, September 2005

ISCORMA-3, Cleveland, Ohio, September 2005 Dyrobes Rotordynamics Software https://dyrobes.com ISCORMA-3, Cleveland, Ohio, 19-23 September 2005 APPLICATION OF ROTOR DYNAMIC ANALYSIS FOR EVALUATION OF SYNCHRONOUS SPEED INSTABILITY AND AMPLITUDE HYSTERESIS

More information

Full Scale Experimental Evaluation for Cable Dampers

Full Scale Experimental Evaluation for Cable Dampers Full Scale Experimental Evaluation for Cable Dampers Liang Dong, Tian Jingxian, Du Chuang, Ma Jinlong Abstract One of the key techniques for building long span cable-stayed bridge is the mitigation of

More information

Parameter optimisation design for a six-dof heavy duty vehicle seat suspension

Parameter optimisation design for a six-dof heavy duty vehicle seat suspension 11 th World Congress on Structural and Multidisciplinary Optimisation 07 th -12 th, June 2015, Sydney Australia Parameter optimisation design for a six-dof heavy duty vehicle seat suspension Donghong Ning,

More information

Analysis and measurement of damping characteristics of linear generator

Analysis and measurement of damping characteristics of linear generator International Journal of Applied Electromagnetics and Mechanics 52 (2016) 1503 1510 1503 DOI 10.3233/JAE-162166 IOS Press Analysis and measurement of damping characteristics of linear generator Takahito

More information

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles Wenlong Li 1 and K. T. Chau 2 1 Department of Electrical and Electronic Engineering, The University of Hong Kong, wlli@eee.hku.hk

More information

Parametric study on behaviour of box girder bridges using CSi Bridge

Parametric study on behaviour of box girder bridges using CSi Bridge Parametric study on behaviour of box girder bridges using CSi Bridge Kiran Kumar Bhagwat 1, Dr. D. K. Kulkarni 2, Prateek Cholappanavar 3 1Post Graduate student, Dept. of Civil Engineering, SDMCET Dharwad,

More information

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter Article ID: 18558; Draft date: 2017-06-12 23:31 Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter Yuan Chen 1, Ru-peng Zhu 2, Ye-ping Xiong 3, Guang-hu

More information

DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM

DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM Kripa K. Varanasi and Samir A. Nayfeh Department of Mechanical Engineering Massachusetts Institute of Technology Cambridge,

More information

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor > 57 < 1 Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor Masaki Yagami, Non Member, IEEE, Junji Tamura, Senior Member, IEEE Abstract This paper

More information

Vibration Measurement and Noise Control in Planetary Gear Train

Vibration Measurement and Noise Control in Planetary Gear Train Vibration Measurement and Noise Control in Planetary Gear Train A.R.Mokate 1, R.R.Navthar 2 P.G. Student, Department of Mechanical Engineering, PDVVP COE, A. Nagar, Maharashtra, India 1 Assistance Professor,

More information

Student VR SIDDHARTHA ENGINEERING COLLEGE, CIVIL ENGINEERING DEPARTMENT, VIJAYAWADA, INDIA, Andhra Pradesh, India 1.

Student VR SIDDHARTHA ENGINEERING COLLEGE, CIVIL ENGINEERING DEPARTMENT, VIJAYAWADA, INDIA, Andhra Pradesh, India 1. MODIFIED DAMPERS FOR EARTHQUAKE RESISTANT BUILDING 1 S. Bhavya krishna, 2 N. Lakshmi Bhavana 1,2 Student VR SIDDHARTHA ENGINEERING COLLEGE, CIVIL ENGINEERING DEPARTMENT, VIJAYAWADA, INDIA, Andhra Pradesh,

More information

THE NON-LINEAR STRENGTH-WORK OF ALL BODY CONSTRUCTIONS THE HELICOPTER IS - 2 DURING FAILURE LANDING

THE NON-LINEAR STRENGTH-WORK OF ALL BODY CONSTRUCTIONS THE HELICOPTER IS - 2 DURING FAILURE LANDING Journal of KONES Powertrain and Transport, Vol. 15, No. 4 2008 THE NON-LINEAR STRENGTH-WORK OF ALL BODY CONSTRUCTIONS THE HELICOPTER IS - 2 DURING FAILURE LANDING Kazimierz Stanis aw Fr czek Institute

More information

Research on Skid Control of Small Electric Vehicle (Effect of Velocity Prediction by Observer System)

Research on Skid Control of Small Electric Vehicle (Effect of Velocity Prediction by Observer System) Proc. Schl. Eng. Tokai Univ., Ser. E (17) 15-1 Proc. Schl. Eng. Tokai Univ., Ser. E (17) - Research on Skid Control of Small Electric Vehicle (Effect of Prediction by Observer System) by Sean RITHY *1

More information

Research on Test Methods of Frame Torsional Rigidity Lu JIA1,2, Huanyun DAI1 and Ye SONG1

Research on Test Methods of Frame Torsional Rigidity Lu JIA1,2, Huanyun DAI1 and Ye SONG1 International Industrial Informatics and Computer Engineering Conference (IIICEC 2015) Research on Test Methods of Frame Torsional Rigidity Lu JIA1,2, Huanyun DAI1 and Ye SONG1 1 State Key Laboratory of

More information

EFFECTIVENESS OF THE ACTIVE PNEUMATIC SUSPENSION OF THE OPERATOR S SEAT OF THE MOBILE MACHINE IN DEPEND OF THE VIBRATION REDUCTION STRATEGIES

EFFECTIVENESS OF THE ACTIVE PNEUMATIC SUSPENSION OF THE OPERATOR S SEAT OF THE MOBILE MACHINE IN DEPEND OF THE VIBRATION REDUCTION STRATEGIES Journal of KONES Powertrain and Transport, Vol. 25, No. 3 2018 EFFECTIVENESS OF THE ACTIVE PNEUMATIC SUSPENSION OF THE OPERATOR S SEAT OF THE MOBILE MACHINE IN DEPEND OF THE VIBRATION REDUCTION STRATEGIES

More information

Shimmy Identification Caused by Self-Excitation Components at Vehicle High Speed

Shimmy Identification Caused by Self-Excitation Components at Vehicle High Speed Shimmy Identification Caused by Self-Excitation Components at Vehicle High Speed Fujiang Min, Wei Wen, Lifeng Zhao, Xiongying Yu and Jiang Xu Abstract The chapter introduces the shimmy mechanism caused

More information

Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured Pressure Pulsations and to CFD Results

Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured Pressure Pulsations and to CFD Results Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2012 Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured

More information

Multiphysics Modeling of Railway Pneumatic Suspensions

Multiphysics Modeling of Railway Pneumatic Suspensions SIMPACK User Meeting Salzburg, Austria, 18 th and 19 th May 2011 Multiphysics Modeling of Railway Pneumatic Suspensions Nicolas Docquier Université catholique de Louvain, Belgium Institute of Mechanics,

More information

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15)

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15) ME 6505 DYNAMICS OF MACHINES Fifth Semester Mechanical Engineering (Regulations 2013) Unit III PART A 1. Write the mathematical expression for a free vibration system with viscous damping. (N/D 15) Viscous

More information

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM egor@ciam.ru Keywords: Bevel gears, accessory drives, resonance oscillations, Coulomb friction damping Abstract Bevel gear

More information

Rotorcraft Gearbox Foundation Design by a Network of Optimizations

Rotorcraft Gearbox Foundation Design by a Network of Optimizations 13th AIAA/ISSMO Multidisciplinary Analysis Optimization Conference 13-15 September 2010, Fort Worth, Texas AIAA 2010-9310 Rotorcraft Gearbox Foundation Design by a Network of Optimizations Geng Zhang 1

More information

837. Dynamics of hybrid PM/EM electromagnetic valve in SI engines

837. Dynamics of hybrid PM/EM electromagnetic valve in SI engines 837. Dynamics of hybrid PM/EM electromagnetic valve in SI engines Yaojung Shiao 1, Ly Vinh Dat 2 Department of Vehicle Engineering, National Taipei University of Technology, Taipei, Taiwan, R. O. C. E-mail:

More information

College of Mechanical & Power Engineering Of China Three Gorges University, Yichang, Hubei Province, China

College of Mechanical & Power Engineering Of China Three Gorges University, Yichang, Hubei Province, China International Conference on Intelligent Systems Research and Mechatronics Engineering (ISRME 215) Hydraulic Hitch Systems of 9t Tyre Hosting Girder Machine Modeling and Simulation Analysis Based On SIMULINK/ADAMS

More information

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic Original On the Optimum Pipe Diameter of Water Pumping System by Using Engineering Economic Approach in Case of Being the Installer for Consuming Water M. Pang-Ngam 1, N. Soponpongpipat 1 Abstract The

More information

A Study on the Contact Force between Catenary and Pantograph in Duplicate KTX-II Operation

A Study on the Contact Force between Catenary and Pantograph in Duplicate KTX-II Operation IJR International Journal of Railway Vol. 6, No. 1 / March 2013, pp. 1-6 A Study on the Contact Force between Catenary and Pantograph in Duplicate KTX-II Operation Seung-Wook Kang*, Sang-Ahm Kim* and In-Chol

More information

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE

PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE PREDICTION OF PISTON SLAP OF IC ENGINE USING FEA BY VARYING GAS PRESSURE V. S. Konnur Department of Mechanical Engineering, BLDEA s Engineering College, Bijapur, Karnataka, (India) ABSTRACT The automotive

More information

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: METHODOLOGY Design Parameter [250]

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: METHODOLOGY Design Parameter [250] IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY DESIGN AND ANALYSIS OF COMPOSITE LEAF SPRING FOR LIGHT COMMERCIAL VEHICLE (TATA ACE) Miss. Gulshad Karim Pathan*, Prof. R.K.Kawade,

More information

Transverse Distribution Calculation and Analysis of Strengthened Yingjing Bridge

Transverse Distribution Calculation and Analysis of Strengthened Yingjing Bridge Modern Applied Science; Vol. 8, No. 3; 4 ISSN 93-844 E-ISSN 93-85 Published by Canadian Center of Science and Education Transverse Distribution Calculation and Analysis of Strengthened Yingjing Bridge

More information

Active Suspensions For Tracked Vehicles

Active Suspensions For Tracked Vehicles Active Suspensions For Tracked Vehicles Y.G.Srinivasa, P. V. Manivannan 1, Rajesh K 2 and Sanjay goyal 2 Precision Engineering and Instrumentation Lab Indian Institute of Technology Madras Chennai 1 PEIL

More information

INFLUENCE OF TEMPERATURE ON THE PERFORMANCE TOOTHED BELTS BINDER MAGNETIC

INFLUENCE OF TEMPERATURE ON THE PERFORMANCE TOOTHED BELTS BINDER MAGNETIC INFLUENCE OF TEMPERATURE ON THE PERFORMANCE TOOTHED BELTS BINDER MAGNETIC Merghache Sidi Mohammed, Phd Student Ghernaout Med El-Amine, Doctor in industrial automation University of Tlemcen, ETAP laboratory,

More information

SEMI-ACTIVE CONTROLLED BASE-ISOLATION SYSTEM WITH MAGNETORHEOLOGICAL DAMPER AND PENDULUM SYSTEM

SEMI-ACTIVE CONTROLLED BASE-ISOLATION SYSTEM WITH MAGNETORHEOLOGICAL DAMPER AND PENDULUM SYSTEM 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 691 SEMI-ACTIVE CONTROLLED BASE-ISOLATION SYSTEM WITH MAGNETORHEOLOGICAL DAMPER AND PENDULUM SYSTEM P.

More information

ENERGY RECOVERY SYSTEM FROM THE VEHICLE DAMPERS AND THE INFLUENCE OF THE TANK PRESSURE

ENERGY RECOVERY SYSTEM FROM THE VEHICLE DAMPERS AND THE INFLUENCE OF THE TANK PRESSURE The 3rd International Conference on Computational Mechanics and Virtual Engineering COMEC 2009 29 30 OCTOBER 2009, Brasov, Romania ENERGY RECOVERY SYSTEM FROM THE VEHICLE DAMPERS AND THE INFLUENCE OF THE

More information