GE Industrial Solutions Retrofill Door Assemblies for AKD-5, AKD-6, AKD-8 and AKD-10

Size: px
Start display at page:

Download "GE Industrial Solutions Retrofill Door Assemblies for AKD-5, AKD-6, AKD-8 and AKD-10"

Transcription

1 GE Industrial Solutions Retrofill Door Assemblies for AKD-5, AKD-6, AKD-8 and AKD-10 New doors can be ordered for GE Switchgear based on Switchgear type, Legacy Breaker type being replaced, and door size. Doors are available with & without cutouts for accommodating original lamps and ammeters.

2 Table of Contents Related Publications... 2 Doors, Retrofit Ordering and Replacement... 3 Danger... 3 AKD-5, AK25 Retrofit Door Inch, 22-Inch, 27-Inch Door (AKD5, AK25)... 4,6 7, 8 AKD-5, AK50, AK-75, AK-100 Retrofit Door... 9,10,11 Replace AKD5 Door Modify Existing Door... 12,13, 14 AKD-6, AKR-75, AKR-100 Retrofit Door... 15, 16, 17 Replacing AKD6 Doors Modifying Existing Doors AKD-8 / 10, AKR30S, AKR30H, AKR 30/50, AKR-75, AKRH-75,AKRH-100, AKR-125 Retrofit Door Assemblies... 19,20,21 Replacing AKD8/10 Door Assembly Modifying Existing Door Retrofill Escutcheon Kit Spare Notes of 27

3 Related Publications Related Publications Brochure Snapshot Installation Manual AKD8 Installation Manual AKD10 Installation Manual AKD6 Installation Manual AKD5 Accessory: Door Interlock (Door Interlock Kit) Accessory Retrofill Doors Assembly Accessory: Position Switch Plate & Position Switch Assembly & Wiring (Position Switch Kit) Accessory: Neutral Rogowski CT Disconnect (Neutral Assemblies) Accessory: Programmer Disconnects Accessory: Finger Clusters (Cluster Assemblies) Accessory: Secondary Disconnects FAQ Application Guide Guideform Spec Spare/Renewal Parts Guide Publication Number DEA-532 DEE-543 DEH DEH DEH DEH DEH DEH DEH DEH DEH DEH DEQ-171 DET-753 DET-754 DET of 27

4 Doors, Retrofit Ordering and Replacement Danger Turn off all power to switchgear. Tagout and lockout main source, up-stream or main breaker. Failure to comply with these instructions will result in death or serious injury from severe burns caused by arc flashing that has exceedingly high temperatures. Always wear personal protection equipment according to OSHA standards and appropriate to the severity of potential burns. Ensure only qualified personnel install, operate, service, and maintain all electrical equipment. It takes about 5 to 15 minutes to install the retrofill door(s) in the switchgear, but does not include the 20-minute timing claimed for the roll-in replacement. 3 of 27

5 AKD-5, AK25 Retrofit Door Retrofit doors for the can be ordered as required, depending on door size and if you want door cutouts for accommodating lamps and ammeters (Figure 1 and Figure 2). In this section, the particular wireframe figures feature different door sizes. Table 1 lets you specify a door type. It can be ordered by catalogue number by referring to the last column in the table. Some doors allow cutouts for lamps and/or ammeters; some do not. All the doors in Table 1 are right-hand doors. 20-Inch Door (AKD5, AK25) Figure 1. AK25 (20-inch door assembly) with and without Cutouts for Lights 4 of 27

6 Figure 2. AK25 (20-inch door assembly) with Cutouts for Lights and Accessories 22-Inch Door (AKD5, AK25) Figure 3 displays 22-inch door assemblies, with and without cutouts for lights. The next figure, Figure 4 displays cutouts for both lights and accessories. Figure 3. AK25 (22-inch door assembly) with and without Cutouts for Lights 5 of 27

7 Figure 4. AK25 (22-inch door assembly) with Cutouts for Lights and Accessories 27-Inch Door (AKD5, AK25) Figure 5 displays 27-inch door assemblies, with and without cutouts for lights. The next figure, Figure 6, displays cutouts for both lights and accessories. 6 of 27

8 Figure 5. AK25 (27-inch door assembly) with and without Cutouts for Lights Figure 6. AK25 (27-inch door assembly) with Cutouts for Lights and Accessories 7 of 27

9 Table 1. Replacement Door Categories (TOP LEVEL) Description Breaker Type LVS Fascia Cutout Only Cutout Options Plus Lamps Plus Lamps & Ammeter Available Stack Width (in inches) Type Door Width (in inches) Door Bumpout (in inches) CAT # AK25 DOOR AK25 DOOR AK25 DOOR AK25 DOOR AK25 DOOR AK25 DOOR AK25 DOOR AK25 DOOR AK25 AKD5 YES YES YES YES RH 27 YES G1 AK25 AKD5 YES YES RH 20 YES G1 AK25 AKD5 YES YES RH 22 YES G1 AK25 AKD5 YES YES RH 20 YES G1 AK25 AKD5 YES YES RH 22 YES G1 AK25 AKD5 YES YES RH 22 YES G1 AK25 AKD5 YES YES YES YES RH 27 YES G1 AK25 AKD5 YES YES YES YES RH 27 YES G1 8 of 27

10 27-Inch Door, 30-Inch Door, 38-Inch Door (AKD5, AK50 / AKT50 AK-75, AK-100) Retrofit doors for the can be ordered as required, depending on door size and if you want door cutouts for accommodating lamps and ammeters (Figure 7 and Figure 8). In this section, the particular wireframe figures feature different door sizes. Table 2 lets you select a specific door type. It can be ordered by catalogue number by referring to the last column in the table. Two doors allow cutouts for lamps and/or ammeters; one does not allow any cutouts. All the doors in Table 2 are right-hand doors. Figure 7. SHOWN (AK50 (27-inch door assembly) with and without Cutouts for Lights 9 of 27

11 Figure 8. AK50 / AKT50 (27-inch door assembly) with Cutouts for Lights and Accessories 10 of 27

12 Table 2. Replacement Door Categories (TOP LEVEL) Description Breaker Type LVS Fascia Cutout Only Cutout Options Plus Lamps Plus Lamps & Ammeter Available Stack Width (in inches) Type Door Width (in inches) Door Bumpout (in inches) CAT # AK50 DOOR AK50 AKT50 AKD 5 YES YES YES YES RH 27 No G1 AK50 DOOR AK50 AKT50 AKD 5 YES YES YES YES RH 27 No G1 AK50 DOOR AK50 AKT50 AKD 5 YES YES YES YES RH 27 No G1 AK75 DOOR AK75 AKD 5 YES YES RH 30 No G2 AK75 DOOR AK75 AKD 5 YES YES RH 30 No G4 AK75 DOOR AK75 AKD 5 YES YES RH 30 No G6 AK100 DOOR AK100 AKD 5 YES YES RH 38 No G3 AK100 DOOR AK100 AKD 5 YES YES RH 38 No G4 AK100 DOOR AK100 AKD 5 YES YES RH 38 No G7 11 of 27

13 Replace AKD5 Door Sequence of replacement of door assemblies will remain the same for all AKD5 type doors. 1. De-energize/switch off the LVS section that is to be retrofitted. 2. Open the compartment door that is to be retrofitted. 3. Rack out the existing legacy AK/AKR breaker from the LVS. 4. Keep the door open for accessing the door mounting hinges. These are placed on the right side wall of the moving frame in the LVS compartment. 5. The door hinge is mounted via 2/3-mounting pins that hold the door in place. 6. Lift the pin out of the hinge joint. This allows access for removing the old door from the LVS compartment. 7. Unpack the new door assembly and mount it on the door mounting hinges. These are located at the right side of the moving frame. 8. Replace the hinge pins and secure the joints. 9. Insert the new retrofitted EntelliGuard R Retrofill circuit breaker into the compartment and slide the breaker into the disconnected condition. 10. Close the new door and secure it to the compartment. 11. Rack-in the new retrofitted EntelliGuard R Retrofill in. Modify Existing Door If customer doesn t want to buy a new door, the customer can modify the existing door: 1. Remove the legacy door assembly from the LVS section. 2. Modify the door cut out as per the new door cutout template. 3. Check the through-door racking with the new door assembly. AKD-6, AKR, AKR-75, AKR-100 Retrofit Door Retrofit doors for the can be ordered as required, depending on door size and if you want door cutouts for accommodating lamps and ammeters. Table 3 lets you select a specific door type (Figure 9 and Figure 10). In this section, the particular wireframe figures different door 12 of 27

14 sizes. It can be ordered by catalogue number by referring to the last column in the table. Some doors allow cutouts for lamps and/or ammeters; some do not. All the doors in Table 3 are right-hand doors. 22-Inch, 30-Inch Door (AKD6) Figure 9. AKD6 SHOWN (22-inch door assembly) with and without Cutouts for Lights 13 of 27

15 Figure 10. AKD6 SHOWN (22-inch door assembly) with Cutouts for Lights and Accessories 14 of 27

16 27-Inch, 30-Inch Door Sizes (AKD6) For the AKD6, Figure 11 displays the 27-inch door assembly with and without cutouts for lights. Figure 12 shows cutouts or punch-outs for the same door assembly. Figure 11. AKD6 SHOWN (27-inch door assembly) with and without Cutouts for Lights 15 of 27

17 Figure 12. AKD6 SHOWN (27-inch door assembly with Cutouts for Lights and Accessories 16 of 27

18 Table 3. Replacement Door Categories (TOP LEVEL) Description Legacy Breaker Type LV Swgr Fascia Cutout Only Cutout Options Plus Lamps Plus Lamps & Ammeter Available Stack Width (in inches) Type Door Width (in inches) Door Bumpout (in inches) CAT # AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKD6 DOOR AKR- 30/50/T50 AKR- 30/50/T50 AKR- 30/50/T50 AKR- 30/50/T50 AKR- 30/50/T50 AKR- 30/50/T50 AKR75 AKR100 AKR75 AKR100 AKR75 AKR100 AKD6 YES YES RH 22 No G1 AKD6 YES YES RH 22 No G1 AKD6 YES YES RH 22 No G1 AKD6 YES YES YES YES RH 27 No G1 AKD6 YES YES YES YES RH 27 No G1 AKD6 YES YES YES YES RH 27 No G1 AKD6 YES YES RH 30 No G2 AKD6 YES YES RH 30 No G4 AKD6 YES YES RH 30 No G6 17 of 27

19 Replacing AKD6 Door Assembly Sequence of replacement of door assemblies will remain the same for all AKD6 type doors. 1. De-energize/switch off the LVS section that is to be retrofitted. 2. Open the compartment door that is to be retrofitted. 3. Rack out the existing legacy AK/AKR breaker from the LVS. 4. Keep the door open for accessing the door mounting hinges. These are placed on the right side wall of the moving frame in the LVS compartment. 5. The door hinge is mounted via 2/3-mounting pins that hold the door in place. [What does the 2/3 mean: size, inches, type, etc.?] [How many pins are there per door?] 6. Lift the pin out of the hinge joint. This will provide access for removing the old door from the LVS compartment. 7. Unpack the new door assembly and mount it on the door mounting hinges. These are placed [found?] [or are they already installed there?] at the right side of the moving frame. 8. Replace the hinge pins and secure the joints. 9. Insert the new retrofitted EntelliGuard R Retrofill circuit breaker into the compartment and slide the breaker into the disconnected condition. 10. Close the new door and secure it to the compartment. 11. Rack-in the new retrofitted EntelliGuard R Retrofill in. [OK, what do I do with the old door? Discard it salvage it for something else?] Modifying Existing Door If customer doesn t want to buy a new door, the customer can modify the existing door: 1. Remove the legacy door assembly from the LVS section. 2. Modify the door cut out as per the new door cutout template. 3. Check the through-door racking with the new door assembly. 18 of 27

20 AKD-8 / 10, AKR30S, AKR30H, AKR 30/50/, AKR-75, AKRH-75, AKRH-100, AKR-125 Retrofit Door Assemblies Retrofit doors can be ordered as required, depending on door size and if you want door cutouts for accommodating lamps and ammeters (Figure 13, Figure 14, and Figure 15). Table 4 lets you select a specific door type. It can be ordered by catalogue number by referring to the last column in the table. Some doors allow cutouts for lamps and/or ammeters; some do not. All the doors in Table 4 are right-hand doors. 22-Inch, 30-Inch, 38-Inch RH AKD8/10 Figure 13. AKD8/10 SHOWN (22-inch door assembly) see G2 for BOM Figure 14. AKD8/10 SHOWN (30-inch door assembly) See G1 for BOM 19 of 27

21 Figure 15. AKD8 AKR30S (30-inch door assembly) 20 of 27

22 Table 4. Replacement Door Categories (TOP LEVEL) Description Legacy Breaker Type LV Swgr. Cutout Options Fascia Cutout Only (includes door interlock bracket) Available Stack Width (in inches) Type Door Width (inches) Door Bump-out (inches) CAT # 22 DOOR AKR30S AKR-30S AKD-8 YES YES RH 22 YES G1 30 DOOR AKR30S AKR-30S AKD-8 YES YES RH 30 YES G1 22 DOOR, AKD-8 & AKD-10 AKR-30/50/T50 WP-08/16/20 AKD-8 & AKD-10 YES YES RH 22 G1-YES 1 G2-NO G1/2* 30 DOOR, AKD-8 & AKD-10 AKR-30/50/T50 WP-08/16/20 AKD-8 & AKD-10 YES YES RH 30 NO G1 30 DOOR, AKD-8 ONLY 38 DOOR, AKD-8 ONLY 30 DOOR, AKD-10 ONLY 38 DOOR, AKD-10 ONLY AKR-75/100 AKD-8 YES YES RH 30 NO G2 AKR-125 AKD-8 YES YES RH 38 NO G4 WP-32 & WP-40 AKD-10 YES YES RH 30 NO G3 WP-50 AKD-10 YES YES RH 38 NO G5 +Bump-out doors for AKR-30S Retrofills only *G1 -angled bump-out for early Model 1 Retrofills and G2 - later Model 1 s & Model 2 Retrofills for AKR-30/50/T50, and all small frame WavePro. 21 of 27

23 Replacing AKD-8/10 Door Assembly Figure 16A & B are examples of new retrofill doors for the newly installed retrofill breakers. (Note that the figure16a shows that a motor can power the racking-in of the retrofill breaker.) Figure 16A. Remote Racker Assembled to Retrofill in AKD-8 Figure 17B. New Door Assembled on AKD-10 38"-Door, 5000A Sequence of replacement of door assemblies will remain the same for all AKD8 /10 type doors. 1. De-energize/switch off the LVS section that is to be retrofitted. 2. Open the compartment door that is to be retrofitted. 3. Rack out the existing legacy AK/AKR breaker from the LVS 4. Keep the door open for accessing the door mounting pads placed on the right side wall in the LVS compartment. 22 of 27

24 5. Loosen the screws holding the mounting pads to the compartment frame. 6. Note that this will provide access for removing the old door from the LVS compartment. 7. Unpack the new door assembly and mount it on the compartment and secure via placing the pads and tightening the screws. 8. Insert the new retrofitted EntelliGuard R Retrofill circuit breaker into the compartment and slide the breaker into the disconnected condition. 9. Close the new door and secure it to the compartment. 10. Rack-in the new retrofitted EntelliGuard R Retrofill circuit breaker in. Modifying Existing Door If customer doesn t want to buy a new door, the customer can modify the existing door: 1. Remove the legacy door assembly from the LVS section. 2. Modify the door cut out as per the new door cutout template. 3. Check the through-door racking with the new door assembly. 23 of 27

25 Figure 18 shows a legacy breaker in the cabinet with the old doors still attached. Figure 19 shows the retrofill breaker, racked in a compartment, waiting for a retrofill door to be installed. The other three compartment doors have the retrofill doors already, but no retrofill breakers yet. Figure 18. Legacy AK with Old Door Figure 19. AKR with New Door 24 of 27

26 Retrofill Escutcheon Kit Spare Table 5 displays some kit options. Table 5. Escutcheon Options Kit Description Breaker Type LV Swgr No Cutouts Fascia Cutout Only Plus Lamps Plus Lamps & Ammeter Available Stack Width (in inches) CAT # AK-25 AKD-5 YES YES YES YES YES Retrofill Escutcheon Kit Spare AKR AKD-6 N/A YES YES YES YES AKR AKD-8 / 10 AKR- 30S N/A YES YES YES YES G1 AKR AKD-8 / 10 Regular N/A YES YES YES YES Escutcheon Kit AK-50 AKD-5 N/A N/A YES YES YES G1 Escutcheon Kit AK & AKR- 75/100 Only AKD-5 & AKD-6 N/A N/A N/A YES YES G2 25 of 27

27 Notes 26 of 27

28 GE Industrial Solutions 41 Woodford Avenue Plainville, CT General Electric Company Rev. 3 (10/16) 27 of 27

Programmer Disconnect Accessory Manual for Retrofil CB

Programmer Disconnect Accessory Manual for Retrofil CB GE Energy Programmer Disconnect Accessory Manual for Retrofil CB Programmer secondary disconnects are not provided on AKD5 legacy LVS breakers. If the customer has chosen to utilize the advanced features

More information

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers GE Industrial Solutions Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers This position switch actuator, mounted on the cassette using simple hardware, is an actuator or

More information

Finger Cluster Replacement Parts Primary Disconnects for EntelliGuard* Retrofill Circuit Breakers

Finger Cluster Replacement Parts Primary Disconnects for EntelliGuard* Retrofill Circuit Breakers GE Industrial Solutions Finger Cluster Replacement Parts Primary Disconnects for EntelliGuard* Retrofill Circuit Breakers The primary disconnects are flexible connections between the breaker and line and

More information

Operation and Maintenance Manual

Operation and Maintenance Manual DEH-41482 GE Energy Industrial Solutions Low Voltage Switchgear Remote Racking Operator For AKR Circuit Breakers Cat. # AKREGRR 115 VAC, 60/50 Hertz Operation and Maintenance Manual TABLE OF CONTENTS Section

More information

EntelliGuard R Retrofill Application Guide

EntelliGuard R Retrofill Application Guide GE Energy EntelliGuard R Retrofill Application Guide imagination at work Table of Contents Table of Contents...1 Introduction...3 Benefits of Retrofill...3 Features...4 Offering and Ratings...6 Testing

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing

More information

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit GE Industrial Solutions DET-809 Installation Instructions AMP1N4 Enclosure for AMP1 Series Energy Meters with Swing Panel Kit Safety FCC PART 15 INFORMATION NOTE: This equipment has been tested by the

More information

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System GE Industrial Solutions DEH-41474 Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System Table of Contents General Information... ii Hazard Classifications... ii Trademarks...

More information

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4

More information

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation DEH41118 Installation Instructions R01 R02 g EntelliGuard Power Circuit Breaker Accessories Network Interlock for 3200-5000 Ampere Circuit Breakers Introduction The Network Interlock provides a means of

More information

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION Instruction Bulletin Bulletin No. 44027-017-01 Middletown, OH USA Class 6035 INTRODUCTION This bulletin contains instructions for adding a shunt trip assembly to a manual DS/DSL circuit breaker and modifying

More information

Power delivery for industrial facilities

Power delivery for industrial facilities Power delivery for industrial facilities New construction, expansions, services and modernization imagination at work For more than a century GE has designed, built, installed and serviced the electrical

More information

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary. GE Industrial Solutions EntellEon * Low-Voltage Power Panel Simple. Responsive. Revolutionary. Introducing EntellEon A More Versatile Alternative to Traditional Power Panels EntellEon, the new low-voltage

More information

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units GE Energy Industrial Solutions GEH-6255 Installation Instructions Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip

More information

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator GE Consumer & Industrial Electrical Distribution Operation & Maintenance Manual GEK-99986 Catalog # WPEGRRLV 115 VAC, 60/50 Hz Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking

More information

Installation, Operation, and Maintenance Manual Retain for Future Use. EntelliGuard G Circuit Breaker

Installation, Operation, and Maintenance Manual Retain for Future Use. EntelliGuard G Circuit Breaker Installation, Operation, and Maintenance Manual Retain for Future Use. EntelliGuard G Circuit Breaker 2 2012 General Electric All Rights Reserved HAZARD CATEGORIES The following important highlighted information

More information

Zone Selective Interlock Module. For GE Circuit Breakers

Zone Selective Interlock Module. For GE Circuit Breakers GE Zone Selective Interlock Module For GE Circuit Breakers Table of Contents 1. Introduction... 4 What is Zone-Selective Interlocking (ZSI)?...4 What is a Zone-Selective Interlock Module?...4 2. Description...

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear IMPORTANT The information contained herein is general in nature and not intended for specific application purposes. It does not relieve the

More information

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200

More information

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers DEH41480 Test Cabinet (Inspection Box) for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers Instructions 1 Table of Contents Section 1. Introduction

More information

TIME REQUIREMENT GUIDE (TRG)

TIME REQUIREMENT GUIDE (TRG) CAT SWITCHGEAR TIME REQUIREMENT GUIDE (TRG) This warranty repair time requirement guide is designed to: Provide detailed guidance on troubleshooting Determine possible solutions Guide the technician to

More information

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions g DEH41081 Installation Instructions A Series Lighting Control Panelboards R02 Introduction These instructions describe the installation of a AE Series lighting control panel interior with internally mounted

More information

Factory Authorized Mechanism Enhancement (FAME)

Factory Authorized Mechanism Enhancement (FAME) Instruction Leaflet IL182403EN Supersedes April 2017 Effective July 2018 Factory Authorized Mechanism Enhancement (FAME) FAME Upgrade Shown Factory Authorized Mechanism Enhancement (FAME) DISCLAIMER OF

More information

ABB Power Products Medium Voltage MV SERVICE. Florence, SC Napa, CA Coral Springs, FL. ABB Inc. -1- March, 2007

ABB Power Products Medium Voltage MV SERVICE. Florence, SC Napa, CA Coral Springs, FL. ABB Inc. -1- March, 2007 ABB Power Products Medium Voltage MV SERVICE ABB Inc. -1- Florence, SC Napa, CA Coral Springs, FL Issues of Aging Switchgear Switchgear and Breakers are beyond a reasonably expected life Existing breaker

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com SPEC-SETTER Type TH HEAVY DUTY SAFETY ES LOAD BLOCK CATALOG MODEL NUMBER NO. BLOCK THJ 343L68G97 TH M 343L68G97 THMK 343L68G97 THMSS 343L68G97 THSS 343L68G97 THJ 343L68G0 THM 343L68G0 THMK 343L68G0 THMSS

More information

SecoVac * R Retrofill

SecoVac * R Retrofill GE Energy Connections DEA-614 Brochure SecoVac * R Retrofill 5kV-15kV Replacement Vacuum Circuit Breakers: The Next Generation of Reliability, Performance and Sustainability GE GE is a diversified organization

More information

SecoVac * Ground & Test Device

SecoVac * Ground & Test Device GE Industrial Solutions DEH-50007 Installation, Operation and Maintenance Manual SecoVac * Ground & Test Device For 5kV-15kV IEEE Metal-clad Switchgear Table of Contents 1. Introduction...6 Safety Precautions...6

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers g DEH-126 Supplementary Instructions MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers SUPPLEMENTARY INSTRUCTIONS ONLY This publication

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

GEH-6259 Installation Instructions Voltage Conditioner Assembly

GEH-6259 Installation Instructions Voltage Conditioner Assembly GE Industrial Solutions GEH-6259 Installation Instructions Voltage Conditioner Assembly For use with microentelliguard*, EntelliGuard TU, MicroVersaTrip* PM or MicroVersaTrip* Plus Trip Units For Catalog

More information

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions DEH40915 Installation Instructions g Plug In Base Congratulations and thank you for choosing the Record Plus TM family of current-limiting circuit breakers. This UL-listed Plug-In Mounting Plate accessory

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

Company Switch Installation Instructions and User Manual

Company Switch Installation Instructions and User Manual Lex Products Corporation 15 Progress Drive Shelton, CT 06484 203.363.3738 203.363.3742 Fax Lex West 11847 Sheldon Street Sun Valley, CA 91352 818.768.4474 818.768.4040 Fax www.lexproducts.com info@lexproducts.com

More information

Effective November 2016 Supersedes September 1998 (S )

Effective November 2016 Supersedes September 1998 (S ) Fusing Equipment MN132018EN Effective November 2016 Supersedes September 1998 (S240-84-1) X-Limiter Hinge-Mount for S&C SMD -20 Fuse Mounting Assembly and Installation Instructions COOPER POWER SERIES

More information

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers Supersedes IL 33-GDC-5 Dated 07/10 Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers Digitrip Retrofit System for the General Electric AKR Digitrip Retrofit

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low

More information

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking)

Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking) Instructional Booklet IB022010EN Instructions for installation, operation, and maintenance of medium voltage VC-W MR2 (integral racking) Contents Description Page Notices and warnings.... 4 Introduction....

More information

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers Section Contents 9 Section 9 Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers Page INTRODUCTION... 9- APPLICATION... 9- TESTING... 9- LONGER LIFE... 9- QUALITY... 9- INSTALLATION...

More information

Power/Vac OEM Express Switchgear

Power/Vac OEM Express Switchgear g Power/Vac OEM Express Switchgear Metalclad Switchgear 4.16kV-250 MVA through 13.8kV-1500 MVA DEA-275 FULLY ASSEMBLED MECHANICALLY COMPLETE SWITCHGEAR WITHOUT DEVICES AND WIRE. POWER/VAC OEM EXPRESS SWITCHGEAR

More information

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE Carlo GEMME Paola BASSI Giorgio MAGNO ABB - Italy ABB - Italy ABB - Italy carlo.gemme@it.abb.com paola.bassi@it.abb.com giorgio.magno@it.abb.com

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

GE Industrial Solutions Power Protection. LV Switchgear SEN Plus

GE Industrial Solutions Power Protection. LV Switchgear SEN Plus GE Industrial Solutions Power Protection LV Switchgear SEN Plus A position in a portfolio SEN Plus 2/ Electrical parameters Rated operational voltage: Ue 690 V AC 40-60 Hz, 600 V DC Rated insulation voltage

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY

More information

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION

More information

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers Specification Guide for RMAX Direct Replacement AC Low Voltage Power Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards... 3 3.0 Supplier Qualifications... 3 4.0 Mechanical and

More information

Low Voltage Power Circuit Breakers

Low Voltage Power Circuit Breakers A-TYPE DRAWOUT Electrically Operated I GE/-861508 Installation Instructions Low Voltage Power Circuit Breakers Types AKR-30/50 and A -50 0-TYPE ORA WOUT \ Manually Operated B-TYPE DRAWOUT Electrically

More information

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range. LDE3019ST LDE3017ST LDE3017SB LDE3017SW LDE3015ST LDE3015SB

More information

SecoVac * Vacuum Circuit Breaker

SecoVac * Vacuum Circuit Breaker GE DEH-50001 Installation, Operation and Maintenance Manual SecoVac * Vacuum Circuit Breaker For 5kV-15kV IEEE Metal-clad Switchgear Table of Contents 1. Introduction... 7 2. Safety Instruction... 8 3.

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker IL 33-LGH-1 Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

Controlled Power HSN High Speed DC Circuit Breakers

Controlled Power HSN High Speed DC Circuit Breakers Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the

More information

Electric Range installation manual

Electric Range installation manual Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

SecoVac * R Retrofill Vacuum Circuit Breaker

SecoVac * R Retrofill Vacuum Circuit Breaker GE DEH-5000 User Manual SecoVac * R Retrofill Vacuum Circuit Breaker 5-5kV 200A & 2000A Table of Contents. Introduction...5 Definitions...5 2. Safety...6 3. Receiving...7 Inspecting for Damage...7 Filing

More information

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version IB131018EN Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version Contents Description Page 1. Introduction...2 2. Description...2

More information

www. ElectricalPartManuals. com Section 6 Low Voltage Power and DC Circuit Breakers

www. ElectricalPartManuals. com Section 6 Low Voltage Power and DC Circuit Breakers Introduction...6-1 EntelliGuard G Low Voltage Power Circuit Breakers...6-2 WavePro Circuit Breakers with Power+, Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Systems...6-3 WavePro Low Voltage

More information

Installation Instructions For Motor Control Center (MCC) Units

Installation Instructions For Motor Control Center (MCC) Units s Page 1 of 8 Installation Instructions December, 2013 Installation Instructions For Motor Control Center (MCC) Units Hazardous voltage. Will cause death or serious injury. Always de-energize and ground

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Eilat, 11/2017. Cost Effective switchgear Modernization solutions

Eilat, 11/2017. Cost Effective switchgear Modernization solutions Eilat, 11/2017 Cost Effective switchgear Modernization solutions Asset upgrade Today s situation Aging of install base. Demands for Health & Safety Standards. Demands for improve quality of supply. Lose

More information

6900-( )-( ) HIGH SPEED SANDWICH PRESS

6900-( )-( ) HIGH SPEED SANDWICH PRESS SERVICE MANUAL 6900-( )-( ) HIGH SPEED SANDWICH PRESS CAUTION PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow

More information

Power Break Circuit Breakers

Power Break Circuit Breakers Draw Out 800-4000 Amperes GEH-46988 Installation Instructions Power Break Circuit Breakers POWER BREAK Draw Out Circuit Breaker (SOOA 4000A) DESCRIPTION Types TC, and THC Power Break draw out circuit breakers

More information

Air Circuit Breaker Retrofitting

Air Circuit Breaker Retrofitting Air Circuit Breaker Retrofitting Future proof your protection system with NHP retrofitting services POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products AUS NZ 1300 NHP NHP 0800 NHP NHP

More information

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670 Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670 80043-760-03 06/2009 Peru, IN, USA Retain for future use. Introduction This bulletin

More information

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance M E T A L - C L A D S W I T C H G E A R Safe and Reliable Flexible, Compact Design Easy Installation and Maintenance We build a better future! Hyundai HMS medium-voltage metal-clad switchgears and control-gears,

More information

MEDIUM VOLTAGE PRODUCTS

MEDIUM VOLTAGE PRODUCTS MEDIUM VOLTAGE PRODUCTS Anything is possible with MYERS POWER PRODUCTS PROTECT Protect your equipment and personnel from the elements and unforeseen electrical events with Myers Medium Voltage Products

More information

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180 ST Series Service Tester Phase Identifier Operating Instructions ST500PGN REV. ED. 101229 CONTENTS Limitation of Warranty and Liability

More information

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL TABLE OF CONTENTS Introduction...3 Warranty...3 On-Line Warranty Registration...3 Safety Instructions........................................................3

More information

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2 SAFETY PRECAUTIONS POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY FEATURES

More information

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the

More information

Technical Specificaions. kwh Energy Meter

Technical Specificaions. kwh Energy Meter Technical Specificaions of kwh Energy Meter (SPK300) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS

WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS etc-12 e-series, direct replacement retrofit for WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS Section 1 Installation Manual Contents Introduction. 1 Required Tools 2 Pre-Installation 2 Programmer Installation.

More information

Operator Manual. This operator manual has. information for all models. of series M plus some. options and accessories. Some of the illustrations

Operator Manual. This operator manual has. information for all models. of series M plus some. options and accessories. Some of the illustrations M S E R I E Operator Manual S This operator manual has information for all models of series M plus some options and accessories. Some of the illustrations and information may not The most apply to your

More information

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering for GE Meter Mod * III Modular Metering Your guide to GE s GE tenant main circuit breakers are typically used in residential and light commercial group metering applications. This product category offers

More information

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A

MOULDED CASE CIRCUIT BREAKERS 16A TO 630A TEMBREAK 2 MOULDED CASE CIRCUIT BREAKERS 16A TO 630A 1. Welcome to TemBreak 2 2. Ratings and Specifications 3. Operating Characteristics 4. Application Data 5. Accessories 6. Installation 7. Dimensions*

More information

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content 1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and

More information

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit

More information

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices IB 6.2.13.7-1 1 Rev. 4, June 2000 ADVAC TM INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices Power T&D Company, Inc. Distribution Systems Division

More information

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640 Instruction Bulletin 4-722-2 /29 Peru, IN, USA Replaces 4-722-1 1/28 Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 164 Retain for future use. Introduction

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual

More information

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers User manual W-VACi W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers 65A7355H01 Rev.04 January 2013 www.eaton.com 2 Table of contents 1 Safety... 5 1.1 Safety precautions...5 1.2 Safety practices...5

More information

Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9968

Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9968 Vacuum Circuit Breakers (Vehicle) Type FSV 5kV to 15kV Instructions Installation Operation Maintenance SGIM-9968 Hazardous voltages and high-speed moving parts. Will cause death, serious injury or equipment

More information

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use. Instruction Bulletin Retain for future use. MASTERCLAD Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class 6055 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully

More information

Vacuum Circuit Breakers (Vehicle)

Vacuum Circuit Breakers (Vehicle) Vacuum Circuit Breakers (Vehicle) Type DTR 7.5kV to 15kV Instructions Installation Operation Maintenance SGIM-9938B Hazardous voltages and high-speed moving parts. Will cause death, serious injury or equipment

More information

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection

More information

Original. User Manual & Install Guide. Safe-T-Pull Inc. Page 1 of 15

Original. User Manual & Install Guide. Safe-T-Pull Inc. Page 1 of 15 Original User Manual & Install Guide Safe-T-Pull Inc. Page 1 of 15 TABLE OF CONTINENTS 1. Before You Begin...3 Disclaimer...3 What Is Included...3 Claims...3 Contact Us...4 Safety Notes...4 2. Introduction...5

More information

Cradle Mounted Key Interlock Guide Frame Accessory

Cradle Mounted Key Interlock Guide Frame Accessory s Cradle Mounted Key Interlock Guide Frame Accessory Cat. No.: WLDLKRK, WLDLSUP, WLDLDKRK, WLDLDSUP, WLDLPR, WLDLDPR For Use With: Circuit Breaker Adapters WLG _ 3 Installation Instructions Instruction

More information

Quick Start Guide TS 910 & TS 920

Quick Start Guide TS 910 & TS 920 Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition

More information

Freedom egen System End-of- Line Functional Checklist

Freedom egen System End-of- Line Functional Checklist U Freedom egen System End-of- Line Functional Checklist 976-0361-01-01 Rev A April 2018 DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This checklist is in addition to, and incorporates

More information