North American Power Fuses

Size: px
Start display at page:

Download "North American Power Fuses"

Transcription

1 North American Power Fuses The most popular North American power fuses to meet the most popular protection priorities. Your problem: Today, you need a time-delay power fuse that can handle normal surges. Tomorrow, it s a power fuse with a high interrupting rating and the added security of rejection dimensions. The day after that, one of those economical one-time power fuses will do the trick. ut where can you turn for all three? Our solution: Ferraz Shawmut s comprehensive power fuse offering covers a complete range of applications and a complete range of circuit-protection needs. Whether it s the characteristics of our Tri-onic time-delay fuses. The high current-limiting capacity of our original Amp-trap power fuses. The cost-efficient protection of our One-Time fuses. Or some other application-specific power fuse solution. Want more information fast? For more technical or applicationspecific information, please call our Power Fuse experts, at ; in Canada; or visit our website at us.ferrazshawmut.com. Class RK5 / Tri-onic TR & TRS DC-rated / Tri-onic TRS-RDC Class J / Amp-trap HSJ Class J / Amp-trap A4J Class L / Amp-trap A4Y Class L / Amp-trap A4T Class T / Amp-trap A3T & A6T Class RK1 / Amp-trap A2K & A6K Class RK1/Amp-trap HSRK Class G / Amp-trap AG Class CC / Amp-trap ATMR Class K-5 / OT, OTN & OTS One-time Class H / RF/RFS & RL/RLS Renewable

2 TRI-ONIC TR & TRS Time Delay/Class RK5 The industry s Most popular fuse for Motor circuit protection. Tri-onic SmartSpot fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product the TR and TRS current limiting time delay fuses are engineered for overcurrent protection of motors and transformers, service entrance equipment, feeder and branch circuits. Tri-onic proven time delay characteristic safely handles harmless starting currents and inrush currents associated with today s motors and transformers. Features/enefits Solid State SmartSpot Indicator Time delay for motor start-ups and transformer inrush currents without nuisance opening Current limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and high current limitation HIGHLIGHTS: Applications: Time Delay Current Limiting AC & DC Rated Motor Circuits Mains Feeders ranch Circuits Transformers Service Entrance Equipment General-purpose Protection Ratings TR AC: 1/10 to 600A 250VAC, 200kA I.R. DC: 1/10 to 2 8/10A & 35 to 400A, 250VDC, 20kA I.R.; 3 to 30A & 450 to 600A, 160VDC, 20kA I.R. Approvals UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No DC Listed to UL Standard 248 TRS only TRS AC: 1/10 to 600A 600VAC, 200kA I.R. DC: 1/10 to 12A, 600VDC, 20kA I.R.; 15 to 60A, 300VDC, 20kA I.R. 70 to 600A, 600VDC, 100kA I.R.

3 TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1/10 TR1/10R TRS1/10R 3-1/2 TR3-1/2R TRS3-1/2R 50 TR50R TRS50R 15/100 TR15/100R TRS15/100R 4 TR4R TRS4R 60 TR60R TRS60R 2/10 TR2/10R TRS2/10R 4-1/2 TR4-1/2R TRS4-1/2R 70 TR70R TRS70R 3/10 TR3/10R TRS3/10R 5 TR5R TRS5R 75 TR75R TRS75R 4/10 TR4/10R TRS4/10R 5-6/10 TR5-6/10R TRS5-6/10R 80 TR80R TRS80R 1/2 TR1/2R TRS1/2R 6 TR6R TRS6R 90 TR90R TRS90R 6/10 TR6/10R TRS6/10R 6-1/4 TR6-1/4R TRS6-1/4R 100 TR100R TRS100R 8/10 TR8/10R TRS8/10R 7 TR7R TRS7R 110 TR110R TRS110R 1 TR1R TRS1R 8 TR8R TRS8R 125 TR125R TRS125R 1-1/8 TR1-1/8R TRS1-1/8R 9 TR9R TRS9R 150 TR150R TRS150R 1-1/4 TR1-1/4R TRS1-1/4R 10 TR10R TRS10R 175 TR175R TRS175R 1-4/10 TR1-4/10R TRS1-4/10R 12 TR12R TRS12R 200 TR200R TRS200R 1-6/10 TR1-6/10R TRS1-6/10R 15 TR15R TRS15R 225 TR225R TRS225R 1-8/10 TR1-8/10R TRS1-8/10R 17-1/2 TR17-1/2R TRS17-1/2R 250 TR250R TRS250R 2 TR2R TRS2R 20 TR20R TRS20R 300 TR300R TRS300R 2-1/4 TR2-1/4R TRS2-1/4R 25 TR25R TRS25R 350 TR350R TRS350R 2-1/2 TR2-1/2R TRS2-1/2R 30 TR30R TRS30R 400 TR400R TRS400R 2-8/10 TR2-8/10R TRS2-8/10R 35 TR35R TRS35R 450 TR450R TRS450R 3 TR3R TRS3R 40 TR40R TRS40R 500 TR500R TRS500R 3-2/10 TR3-2/10R TRS3-2/10R 45 TR45R TRS45R 600 TR600R TRS600R Note: Indicator not available (1/10-7) amps. 0-60A A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-TR FUSES / / / / /8 3 3/ / / / / / / / / / / / / / / V-TRS FUSES / / / / / /8 3 3/ / / / / / / / / / / / /8 80 1/ /4 57 Recommended Fuse locks With ox Connectors For Tri-onic Class RK5 Fuses Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole R 20308R 60306R 60308R R 20608R 60606R 60608R R 21038R 61036R 61038R R 22003R 62001R 62003R R 24003R 64001R 64003R R 2633R 6631R 6633R

4 TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS TR15 to 600 Time in Seconds TR1/10 to 12 Melting Time Current Data, 250V Fuses Current in Amperes Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds

5 TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS TRS15 to 600 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds TRS1/10 to 12 Melting Time Current Data. 600V Fuses Current in Amperes Time in Seconds

6 TRI-ONIC Time Delay/Class RK5 Fuses TR & TRS Peak Let-Thru Current Data TR30 to 600, 250 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes Peak Let-Thru Current Data TRS15 to 600, 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Note: See Application Information page L9 for All Motor and Transformer Tables. Available Current in RMS Symmetrical Amperes

7 tri-onic TRS-RDC time delay/dc rated DC RATED FOR TOUGH DC APPLICATIONS The Tri-onic DC fuse series is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry s most severe third party requirements for 600VDC rated fuses. The TRS-RDC is a time-delay fuse with essentially the same time-current characteristic as the standard Tri-onic. Features/enefits DC rated for mine duty and other long time-constant applications Time delay for motor start-ups and high inrush loads without nuisance opening Rugged glass melamine body for superior Reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Time Delay DC Rated Mine Circuits Trailing Cables Pump Motors Rail Heaters DC: 1 to 30A 300VDC, 20kA I.R. (Consult Factory for Availability) DC: 35 to 400A 600VDC, 20kA I.R. MSHA Approval No

8 TRI-ONIC Time Delay/600VDC Fuses TRS-RDC Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG RATING NUMER 1/10 TRS1/10RDC 15/100 TRS15/100RDC 2/10 TRS2/10RDC 3/10 TRS3/10RDC 4/10 TRS4/10RDC 1/2 TRS1/2RDC 6/10 TRS6/10RDC 8/10 TRS8/10RDC 1 TRS1RDC 1-1/8 TRS1-1/8RDC AMPERE CATALOG RATING NUMER 1-1/4 TRS1-1/4RDC 1-4/10 TRS1-4/10RDC 1-6/10 TRS1-6/10RDC 1-8/10 TRS1-8/10RDC 2 TRS2RDC 2-1/4 TRS2-1/4RDC 2-1/2 TRS2-1/2RDC 2-8/10 TRS2-8/10RDC 3 TRS3RDC 3-2/10 TRS3-2/10RDC AMPERE CATALOG RATING NUMER 3-1/2 TRS3-1/2RDC 4 TRS4RDC 4-1/2 TRS4-1/2RDC 5 TRS5RDC 5-6/10 TRS5-6/10RDC 6 TRS6RDC 6-1/4 TRS6-1/4RDC 8 TRS8RDC 9 TRS9RDC 10 TRS10RDC AMPERE CATALOG RATING NUMER 12 TRS12RDC 15 TRS15RDC 17-1/2 TRS17-1/2RDC 20 TRS20RDC 30 TRS30RDC 35 TRS35RDC 40 TRS40RDC 45 TRS45RDC 50 TRS50RDC 60 TRS60RDC AMPERE CATALOG RATING NUMER 70 TRS70RDC 80 TRS80RDC 90 TRS90RDC 100 TRS100RDC 125 TRS125RDC 150 TRS150RDC 175 TRS175RDC 200 TRS200RDC 250 TRS250RDC 300 TRS300RDC 400 TRS400RDC 0-60 Amperes Dimensions Amperes AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm / / / / / /8 3 3/ / / / / / / / / / /8 48 TRS-RDC60 to 400 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds

9 HSJ HIGH SPEED/CLASS J Protect your wiring and power semiconductors with a single fuse. The new High Speed J (HSJ) combines the low I 2 t of a semiconductor fuse and the branch circuit performance of a Class J UL listed fuse. This fuse was designed for the starting characteristics of solid state motor controllers. The HSJ can provide branch circuit protection per NEC requirements, as well as very low I 2 t for protection of power semiconductors such as Diodes, SCR s, GTO s and SSR s. Features/enefits Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts Low I 2 t (low thermal energy) Excellent Cycling Ability for frequent starts/stops without nuisance opening Ratings Approvals HIGHLIGHTS: Current-Limiting AC & DC Ratings Low l 2 t Compact Size Applications: ranch Circuits Control Panels Electronic Motor Controllers Phase Controllers Drives Soft-Starters Solid State Relays AC: 1-600A 600VAC, 200kA I.R. 300kA I.R. Self Certified DC: A 500VDC, 100kA I.R. L/R 10mS HSJ (15 to 600A) UL Listed to Standard File E2137 DC Listed to UL248 CSA Certified to Standard C22.2 No

10 HIGH SPEED/CLASS J HSJ Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMER OUTLINE FIGURE AMPERE RATING CATALOG NUMER OUTLINE FIGURE 1 HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ /2 HSJ17-1/ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ HSJ80 2 Recommended Fuse locks With ox Connectors for Amp-trap Class J Fuses Fuse Ampere Catalog Number 600V OR LESS Rating 1 Pole 3 pole 0-30 US3J1I US3J3I US6J1I US6J3I J 61038J J 62003J J 64033J J 6633J A variety of pole configurations and termination provisions is available. Dimensions Fig 1 Fig 2 AMPERE RATING A C D E F G H In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm / / / / / /8 29 1/ / /8 92 3/8 10 9/ / /8 41 3/ / / / /8 10 9/ / /8 54 1/ / / / / / /2 64 3/ / / /

11 HIGH SPEED/CLASS J HSJ I 2 t Data Volts AC, 100kA Max Clearing I 2 Max Clearing I 2 Watts Ampere 600V AC 100kA 480V AC 100kA Loss at Rating Pre-Arc 1 Fuse 2 in Series 1 Fuse 2 in Series Rated (A) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) (A 2 s x 10 3 ) Current Clearing I 2 t vs Operating Voltage Watts Loss vs. % Rated Current Correction Factor for I2t AMP AMP Correction Factor for Watts Loss Operating Voltage (AC RMS Volts) Percent Rated Current 11

12 HIGH SPEED/CLASS J HSJ Peak Let-Thru Data - HSJ15 to 600, 600Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes Clearing I 2 t at 500 VDC 100kA, L/R = 10mS DC Voltage vs. Time Constant AMPERE RATING CLEARING I VDC L/R = 10 ms (A 2 s X 10 3 ) DC Voltage Capability L/R Time Constant (ms) 12

13 HIGH SPEED/CLASS J HSJ Melting Time - Current Data, HSJ15 to 600, 600Volts AC Time in Seconds Available Current in RMS Symmetrical Amperes Time in Seconds Available Current in RMS Symmetrical Amperes 13

14 A4J FAST ACTING/Class J For excellent CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability. Features/enefits High current limitation for low peak let-thru current Unique dimensions prevent replacement by other fuse classes Fiberglass body provides dimensional stability in harsh industrial environments Easy-to-read imprint label for quick recognition and replacement HIGHLIGHTS: Applications: Ratings Approvals Fast Acting Very Current-Limiting DC Ratings Capacitors Loadcenters Panelboards Switchboards us Duct Feeder Circuits Circuit reakers Lighting, Heating, and General Loads AC: 1 to 600A 600VAC, 200kA I.R. DC: 1 to 600A 300VDC, 100kA I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No DC Listed to UL 248 IEC

15 fast acting/class J Fuses A4J Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 1 A4J1 50 A4J A4J200 3 A4J3 60 A4J A4J225 6 A4J6 70 A4J A4J A4J10 75 A4J A4J A4J15 80 A4J A4J A4J20 90 A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J A4J175 Recommended Fuse locks With ox Connectors for Amp-trap Class J Fuses 1-60A A Fuse Ampere Catalog Number 600V OR LESS Rating 1 Pole 3 pole 0-30 US3J1I US3J3I US6J1I US6J3I J 61038J J 62003J J 64033J J 6633J A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. Dimensions AMPERE a C D e F G H RATING In. mm In. mm In. mm In. mm In. mm In. mm In. mm In. mm / / / / / /8 29 1/ / /8 92 3/8 10 9/ / /8 41 3/ / / / /8 10 9/ / /8 54 1/ / / / / / /2 64 3/ / / /

16 fast acting/class J Fuses A4J A4J30 to 600 Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data 30 to 600, 600 Volts AC Available Current in RMS Symmetrical Amperes 16

17 A4Y CLASS l count on the high interrupting rating of our most widely-used class L fuse When it comes to protecting service entrance equipment, feeder circuits, and circuit breakers, A4Y fuses have been the industry s favorite. The A4Y is a 100% rated device and may be applied at continuous currents up to its ampere rating. A 4-second minimum time delay at 500% rating allows the A4Y to pass normal current surges and to coordinate with ground fault relays. Features/enefits Unique dimensions prevent replacement by other fuse classes lade stamped catalog numbers for permanent identification Glass melamine body and plated terminals provide superior reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting 4-Second Time Delay DC Ratings Uniform Characteristics in all Ampere Ratings Mains, Feeders Circuit reakers Loadcenters Panelboards Switchboards Metering Centers AC: 200 to 6,000A 600VAC,200kA I.R. DC: 200 to 2500A 300VDC, 100kA I.R. UL Listed to Standard ( A) File E2137 CSA Certified to Standard C22.2 No ( A) Ferraz Shawmut Certified for DC per UL248 ( A) Indicators Optional built-in fuse indicators (-TI) are available. Consult factory. 17

18 Class L Fuses A4Y Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 200 A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A4Y A A A A A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm / / / / / /2 63 3/ / / /2 63 3/ / / / / / / /2 89 1/ / / / / / / / / / / / / / / / / / / / / / / /32 88 Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse. 18

19 Class L Fuses A4Y A4Y200 to 6000 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A4Y300 to 6000, 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 19

20 A4T TIME DELAY/CLASS L when your heavier loads need protection a4t fuses won t let you down The high interrupting rating of A4T current limiting fuses is ideally suited for protecting mains, feeders, and general circuits. The 10-second time delay at 500% of fuse rating is ideal for large motors and other loads with a high inrush. A4T fuses are suitable for DC applications up to 500VDC. An A4T fuse can be applied to normal loads up to its full ampere rating to allow 100% rating of equipment. Features/enefits Unique dimensions prevent replacement by other fuse classes. lade-stamped catalog numbers for permanent identification Glass melamine body and plated terminals provide superior reliability in harsh environments HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting Full 10-Second Delay DC Ratings Uniform Characteristics in all Ampere Ratings Motors Motor Controllers Transformers Mains Feeders AC: 200 to 2,000A 600VAC, 200kA I.R. DC: 200 to 2,000A 500VDC, 100kA I.R. UL Listed to Standard ( A) File E2137 CSA Certified to Standard C22.2 No ( A) Ferraz Shawmut Certified for DC per UL248 ( A) 20

21 Time Delay/Class L Fuses A4T Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER RATING NUMER 200 A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A4T A A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm * 8-5/ / / / / /2 63 3/ / / /2 63 3/ / / / / / / /2 89 1/ / /32 88 Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse. 21

22 Time delay/class l Fuses A4T A4T200 to 2000 Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V AC/500V DC Fuses Current in Amperes Peak Let-Thru Current Data A4T300 to 2000, 600 Volts AC Available Current in RMS Symmetrical Amperes 22

23 A3T & A6T fast acting/class T these small dimension fuses are the right fit... for a tight fit Fast acting A3T and A6T Class T fuses combine two highly desirable features -- high current limitation and a small physical size. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings or current limiting capability. These fuses have glass melamine bodies for superior dimensional stability and catalog numbers stamped into the blades for permanent identification. Features/enefits Extremely current limiting for low peak let-thru current Unique dimensions prevent replacement by other fuse classes lade-stamped catalog numbers for permanent identification Small physical size for greater design flexibility HIGHLIGHTS: Fast Acting Extremely Current Limiting Small Physical Size DC Ratings Applications: Loadcenters Panelboards Switchboards Circuit reakers Metering Centers Recommended Fuse locks With ox Connectors for Amp-trap Class T Fuses Ampere Rating pole 30306T 30606T 31031T 32031T 34031T 36031T Catalog Number 300V 3-pole 1-pole 30308T 60306T 30608T 60606T 31033T 61031T 32033T 62031T 34033T 64031T 66031T A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. 600V 3-pole 60308T 60608T 61033T 62033T Ratings A3T AC:1 to 1200A 300VAC, 200kA I.R. DC: 1 to 1200A 160VDC, 50kA I.R. A6T AC: 1 to 800A 600VAC, 200kA I.R. DC: 1 to 800A 300VDC, 100kA I.R. Approvals UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No DC Listed to UL Standard

24 fast acting/class t Fuses A3T & A6T Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 300V 600V Rating 300V 600V Rating 300V 600V 1 A3T1 A6T1 60 A3T60 A6T A3T300 A6T300 3 A3T3 A6T3 70 A3T70 A6T A3T350 A6T350 6 A3T6 A6T6 80 A3T80 A6T A3T400 A6T A3T10 A6T10 90 A3T90 A6T A3T450 A6T A3T15 A6T A3T100 A6T A3T500 A6T A3T20 A6T A3T110 A6T A3T600 A6T A3T25 A6T A3T125 A6T A3T700 A6T A3T30 A6T A3T150 A6T A3T800 A6T A3T35 A6T A3T175 A6T A3T A3T40 A6T A3T200 A6T A3T A3T45 A6T A3T225 A6T A3T50 A6T A3T250 A6T250 A3T A6T A3T 1-60 A6T 1-30 A6T A3T Dimensions A6T AMPERE A C D F G J RATING In. mm In. mm In. mm In. mm In. mm In. mm In. mm A3T A6T

25 fast acting/class t Fuses A3T & A6T A3T30 to 1200 Melting Time Current Data, 300V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A3T30 to 1200, 300 Volts AC Maximum Instantaneous Peak Let-Thru Amperes 25

26 fast acting/class t Fuses A3T & A6T A6T1 to 800 Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data A6T30 to 800, 600 Volts AC Available Current in RMS Symmetrical Amperes 26

27 A2K & A6K class RK1 these FAST-ACTING FUSES DELIVER A HIGH DEGREE OF CURRENT LIMITATION WHERE YOU NEED IT MOST Current-limiting A2K and A6K fuses provide excellent protection where high available short circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection. Features/enefits Rejection style design prevents replacement by other fuse classes Fiberglass body provides dimensional stability in harsh industrial environments Easy-to-read imprint label for quick recognition and replacement High degree of current limitation for low peak let-thru current HIGHLIGHTS: Applications: Ratings Approvals Highly Current-Limiting Fast Acting Rejection Style Loadcenters Panelboards Switchboards us Duct Feeder Circuits Non-inductive Loads Lighting Circuits A2K AC: 1 to 600A 250VAC, 200kAI.R. DC: 1 to 600A 250VDC, 200kA I.R. A6K AC: 1 to 600A 600VAC, 200kA I.R. DC: 1 to 600A 300VDC, 20kA I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No Ferraz Shawmut Certified for DC per UL248 27

28 fast acting/class rk1 Fuses A2k & A6k Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 A2K1R A6K1R 35 A2K35R A6K35R 175 A2K175R A6K175R 3 A2K3R A6K3R 40 A2K40R A6K40R 200 A2K200R A6K200R 4 - A6K4R 45 A2K45R A6K45R 225 A2K225R A6K225R 5 A2K5R A6K5R 50 A2K50R A6K50R 250 A2K250R A6K250R 6 A2K6R A6K6R 60 A2K60R A6K60R 300 A2K300R A6K300R 8 - A6K8R 70 A2K70R A6K70R 350 A2K350R A6K350R 10 A2K10R A6K10R 80 A2K80R A6K80R 400 A2K400R A6K400R 12 A2K12R - 90 A2K90R A6K90R 450 A2K450R A6K450R 15 A2K15R A6K15R 100 A2K100R A6K100R 500 A2K500R A6K500R 20 A2K20R A6K20R 110 A2K110R A6K110R 600 A2K600R A6K600R 25 A2K25R A6K25R 125 A2K125R A6K125R 30 A2K30R A6K30R 150 A2K150R A6K150R Recommended Fuse locks With ox Connectors For Amp-trap Class RK1 Fuses Dimensions 0-60A A Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole R 20308R 60306R 60308R R 20608R 60606R 60608R R 21038R 61036R 61038R R 22003R 62001R 62003R R 24003R 64001R 64003R R 2633R 6631R 6633R A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-A2K FUSES / / / / /8 3 3/ / / / / / / / / / / / / / / V-A6K FUSES / / / / / /8 3 3/ / / / / / / / / / / / /8 80 1/ /

29 FAST ACTING/CLASS RK1 FUSES A2K & A6K A2K30 to 600 Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds Peak Let-Thru Current Data A2K30 to 600, 250 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 29

30 FAST ACTING/CLASS RK1 FUSES A2K & A6K A6K30 to 600 Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data A6K30 to 600, 600 Volts AC Available Current in RMS Symmetrical Amperes 30

31 HSRK high speed/class rk1 High speed rk1 (HSRK) Protect your electrical power wiring and power semiconductors with a single fuse. The new HIGH SPEED RK1 (HSRK) combines semiconductor fuse performance with NEC branch circuit compliance. The fuse was designed with two specific applications in mind: 1. To provide semiconductor fuse performance to solid state drive applications but in the larger RK body sizes that have been typically installed in older systems. 2. To provide industrial power applications with the most current limiting fuse available, which in turn provides the best arc flash mitigation available to power systems using the larger RK size fuses. Highlights: Current Limiting Low I 2 t Drive protection in larger RK body sizes for older installations Fast acting Applications: ranch circuits AC drives Solid state controllers Feeder circuits Arc flash mitigation Features/enefits Most current limiting RK1 available Provides the best Arc flash mitigation for feeder and branch circuits (non motor load circuits) Excellent cycling ability for frequent drive starts and stops without nuisance opening Extremely Low I 2 t Ratings AC: (70 to 600A) 600VAC, 200KA I.R. 300KA I.R. Self certified Approvals HSRK (70 to 600A) UL listed to File E2137 CSA certified to C No

32 Amp-trap HIGH SPEED/CLASS RK1 HSRK Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog # Ampere Catalog # Rating 600V Rating 600V 70 HSRK70R 200 HSRK200R 80 HSRK80R 225 HSRK225R 90 HSRK90R 250 HSRK250R 100 HSRK100R 300 HSRK300R 110 HSRK110R 350 HSRK350R 125 HSRK125R 400 HSRK400R 150 HSRK150R 450 HSRK450R 175 HSRK175R 500 HSRK500R 600 HSRK600R Recommended Fuse locks With ox Connectors For Amp-trap Class RK1 Fuses Fuse Ampere Catalog Number 600V Rating 1 pole 3 pole R 61038R R 62003R R 64003R R 6633R A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details A Dimensions AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 600V-HSRK FUSES / / /8 3 3/ / / / / / / / / / / / /8 80 1/ /

33 Amp-trap HIGH SPEED/CLASS RK1 HSRK I 2 t Data HSRK (Amp Rating)R Ampere Rating (A) Pre-arc (A 2 s X 10 3 ) Max Clearing I 2 600V AC (A 2 s X 10 3 ) I 2 t vs Working Voltage Watts Loss vs % Rated Current Correction Factor for l 2 t Correction Factor for Watts Loss Working Voltage (AC RMS Volts) % Rated Current 33

34 Amp-trap HIGH SPEED/CLASS RK1 HSRK Watts Loss Data HSRK70 600R, 600V AC Peak Let-Thru Data HSRK70 600R, 600V AC Ampere Rating (A) Watts Loss at Rated Current Maximum Peak Let-Thru Current (A) 60Hz RMS Symmetrcal Prosective Current (A) Melting Time Current Data HSRK70 600R, 600V AC Prearcing Time(s) Prearcing Time(s) Prearc Current (A RMS)±8% Prearc Current (A RMS)±8% 34

35 AG class G amp-trap ag fuses fit right in to a wide variety of industrial applications The Ferraz Shawmut Amp-trap AG fuse series is a complete line of Class G fuses. AG fuses safely fit a wide variety of applications. Class G fuses are made in four physical sizes and provide good branch-circuit protection for lighting, heating, and appliance circuits. Features/enefits Four unique sizes from ½-60 amperes do not allow inter-changeability with other fuse classes Fiberglass bodies provide dimensional stability in harsh industrial settings HIGHLIGHTS: Applications: Ratings Approvals Current-Limiting Time Delay (above 5A) Lighting Heating* Appliances ranch Circuits AC: 1/2 to 20A 600VAC, 100K A I.R. 25 to 60A, 480VAC, 100k A I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No * Except in Canada, where fuses must be P or D type. Dimensions Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER 1/2 AG1/2 15 AG15 1 AG1 20 AG20 1-1/2 AG1-1/2 25 AG25 2 AG2 30 AG30 3 AG3 35 AG35 AMPERE A C RATING In. mm In. mm In. mm 1/2-15A A , 30A A Cross Reference: AG will replace the following fuses: ussmann SC, Littelfuse SLC 4 AG4 40 AG40 5 AG5 45 AG45 6 AG6 50 AG50 8 AG8 60 AG60 10 AG10 35

36 Time Delay/Class g Fuses ag AG1 to 10 Current in Amperes Time in Seconds Current in Amperes Melting Time Current Data, 480V Fuses AG15 to 60 Melting Time Current Data, 480V Fuses Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data AG1 to 60, 480 Volts AC Available Current in RMS Symmetrical Amperes 36

37 ATMR class CC SMALL FUSE - IG PROTECTION FOR GENERAL CIRCUITS Amp-trap ATMR fuses, in the Class CC family, are the smallest dimension 600VAC/DC fuses suitable for branch circuit protection. The ATMR is a popular choice for economical protection of control circuits and control circuit transformers where available short circuit currents exceed 10,000 amperes. ATMR s rejection dimensions prevent substitution by lesser rated fuses. These fast acting fuses give current limiting protection to general circuits. Features/enefits Rejection style design prevents replacement errors when used with recommended fuse blocks Versatile design for individual component and branch circuit protection HIGHLIGHTS: Applications: Ratings Approvals Fast Acting Very Current-Limiting Control Circuits Lighting General Loads ranch Circuit Protection AC: 1/10 to 30A 600VAC, 200kA I.R. DC: 1/10 to 30A 600VDC, 100kA I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No DC Listed to ULStandard 248 Standard Fuse Ampere Ratings, Catalog Numbers AMPERE CATALOG AMPERE CATALOG RATING NUMER RATING NUMER 1/10 ATMR1/10 3-1/2 ATMR3-1/2 1/8 ATMR1/8 4 ATMR4 2/10 ATMR2/10 5 ATMR5 1/4 ATMR1/4 6 ATMR6 3/10 ATMR3/10 7 ATMR7 1/2 ATMR1/2 8 ATMR8 3/4 ATMR3/4 9 ATMR9 1 ATMR1 10 ATMR10 1-1/4 ATMR1-1/4 12 ATMR12 1-1/2 ATMR-1-1/2 15 ATMR15 2 ATMR2 20 ATMR20 2-1/2 ATMR2-1/2 25 ATMR25 3 ATMR3 30 ATMR30 37

38 FAST ACTING/Class CC Fuses atmr Dimensions Recommended Fuse locks For Amp-Trap Class CC Fuses CATALOG NUMER ULTRASAFE Screw Connector Pressure Plate Number of Indicating with Double Connector Copper ox Poles Fuse Holders Quick Connects with Double Connector Quick Connects ADDER 30310R 30320R 30350R 1 USCC1I 30311R 30321R 30351R 2 USCC2I 30312R 30322R 30352R 3 USCC3I 30313R 30323R 30353R 3 USFMCCI Refer to the Class CC Fuse lock section of this catalog for other details. ATMR1/10 to 30 Melting Time Current Data, 600V Fuses Current in Amperes Time in Seconds Maximum Instantaneous Peak Let-Thru Amperes Peak Let-Thru Current Data ATMR3/4 to 30, 600 Volts AC Current in Amperes 38

39 ONE-TIME OT/OTN/OTS class K-5 for versatility and economy, these general purpose fuses are hard to beat OT, OTN and OTS general purpose fuses provide low cost protection for feeder and branch circuits serving lighting, heating, and other non-motor loads. OT, OTN and OTS fuses will safely interrupt available short circuit currents up to 50,000 amperes in all ratings. OT, OTN and OTS fuses are not rejection fuses care should be taken to ensure that replacement fuses do not have lower interrupting ratings than original fuses. OTN 15 through 60 satisfy the Canadian electrical code requirement for Type P, low melting-point, non-time delay fuses. Features/enefits Easy to read imprint label for quick recognition and replacement Low cost for high protection value HIGHLIGHTS: Applications: Ratings Approvals Versatile Lowest cost protection for circuits serving non-inductive loads Feeders ranch Circuits Resistive Heating Residential and Small Commercial Installations OT AC: 1 to 600A 250VAC, 50kA I.R. DC: 1 to 600A 250VDC, 20kA I.R. OTN (Canada) AC: 15 to 60A 250VAC, 50kA I.R. OTS AC: 1 to 600A 600VAC, 50kA I.R. DC: 1 to 600A 300VDC, 20kA I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No * Ferraz Shawmut Certified for DC per UL248 *The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design use OTN

40 ONE-TIME general purpose/class K-5 Fuses ot/otn/ots Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 OT1 OTS1 30 OT30, OTN30* OTS OT125 OTS125 2 OT2 OTS2 35 OT35, OTN35* OTS OT150 OTS150 3 OT3 OTS3 40 OT40, OTN40* OTS OT175 OTS175 4 OT4 OTS4 45 OT45, OTN45* OTS OT200 OTS200 5 OT5 OTS5 50 OT50, OTN 50* OTS OT225 OTS225 6 OT6 OTS6 60 OT60, OTN60* OTS OT250 OTS250 7 OT7 65 OT OT300 OTS300 8 OT8 OTS8 70 OT70 OTS OT350 OTS OT10 OTS10 75 OT75 OTS OT400 OTS OT12 OTS12 80 OT80 OTS OT450 OTS OT15, OTN15* OTS15 90 OT90 OTS OT500 OTS OT20, OTN20* OTS OT100 OTS OT600 0TS OT25, OTN 25* OTS OT110 OTS110 * In Canada Recommended Fuse locks With ox Connectors For One-Time Class K-5 Fuses Dimensions 0-60A A Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole A variety of pole configurations and termination provisions are available. Refer to the fuse block section of this catalog for details. AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-OT, OTN FUSES / / / / /8 3 3/ / / / / / / / / / / / / / / V-OTS FUSES / / / / / /8 3 3/ / / / / / / / / / / / /8 80 1/ /

41 ONE-TIME general purpose/class K-5 Fuses ot/otn/ots OT30 to 600; OTN 30, 60 Melting Time Current Data, 250V Fuses Current in Amperes Time in Seconds OTS30 to 600 Melting Time Current Data, 600V Fuses Peak Let-Thru Current Data OT, OTN & OTS30 to 600, 250 and 600 Volts AC Maximum Instantaneous Peak Let-Thru Amperes Time in Seconds Current in Amperes Available Current in RMS Symmetrical Amperes 41

42 RENEWALE RF/RFS & RL/RLS class H traditional protection for circuits with less than 10,000a SHORT CIRCUIT CURRENT RF and RFS general purpose fuses are suitable for application where available short circuit currents do not exceed 10,000 amperes. RF and RFS renewable fuses use matched RL and RLS die-cut zinc links from 1 to 600 amperes in 32 ratings. Features/enefits Knurled bushings for ease of disassembly Rugged construction for maximum service life Precision die-cut renewal links renew quickly and give repeatable performance HIGHLIGHTS: Applications: Ratings Approvals Renewable 32 Renewal Link Ratings General purpose loads where short circuits are 10,000 amperes or less RF AC: 1 to 600A 250VAC, 10kA I.R. RFS AC: 1 to 600A 600VAC, 10kA I.R. UL Listed to Standard File E2137 CSA Certified to Standard C22.2 No

43 RENEWALE Class h Fuses/links RF/rfS & rl/rls Standard Fuse Ampere Ratings, Catalog Numbers Ampere Catalog Number Ampere Catalog Number Ampere Catalog Number Rating 250V 600V Rating 250V 600V Rating 250V 600V 1 RF1/RL1 RFS1/RLS1 45 RF45/RL45 RFS45/RLS RF225/RL225 RFS225/RLS225 2 RF2/RL2 RFS2/RLS2 50 RF50/RL50 RFS50/RLS RF250/RL250 RFS250/RLS250 3 RF3/RL3 RFS3/RLS3 60 RF60/RL60 RFS60/RLS RF300/RL300 RFS300/RLS300 5 RF5/RL5 RFS5/RLS5 70 RF70/RL70 RFS70/RLS RF350/RL350 RFS350/RLS350 6 RF6/RL6 RFS6/RLS6 80 RF80/RL80 RFS80/RLS RF400/RL400 RFS400/RLS RF10/RL10 RFS10/RLS10 90 RF90/RL90 RFS90/RLS RF450/RL450 RFS450/RLS RF15/RL15 RFS15RLS RF100/RL100 RFS100/RLS RF500/RL500 RFS500/RLS RF20/RL20 RFS20/RLS RF110/RL110 RFS110/RLS RF600/RL600 RFS600/RLS RF25/RL25 RFS25/RLS RF125/RL125 RFS125/RLS RF30/RL30 RFS30/RLS RF150/RL150 RFS150/RLS RF35/RL35 RFS35/RLS RF175/RL175 RFS175/RLS RF40/RL40 RFS40/RLS RF200/RL200 RFS200/RLS200 Recommended Fuse locks With ox Connectors For Renewable Class H Fuses Fuse Catalog Number Ampere 250V 600V Rating 1 Pole 3 pole 1 pole 3 pole A A variety of pole configurations and termination provisions is available. Refer to the fuseholder section of this catalog for details. Dimensions A AMPERE A C D E RATING In. mm In. mm In. mm In. mm In. mm 250V-RF FUSES / / / / /8 3 3/ / / / / / / / / / / / / / / V-RFS FUSES / / / / / /8 3 3/ / / / / / / / / / / / /8 80 1/ /

North American Power Fuses

North American Power Fuses North American Power Fuses THE MOST POPULAR NORTH AMERICAN POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES B Your problem: Today, you need a timedelay power fuse that can handle normal surges.

More information

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES

UL/CSA Listed Power Fuses P F THE MOST POPULAR UL/CSA LISTED POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES UL/CSA Listed Power uses THE MOST POPULAR UL/CSA LISTED POWER USES TO MEET THE MOST POPULAR PROTECTION PRIORITIES P Your problem: Today, you need a timedelay power fuse that can handle normal surges. Tomorrow,

More information

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses... Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES AMP-TRAP 2000 FUSES IN SHORT, AMP-TRAP 2000 FUSES PROTECT YOUR ASSETS A lifeline that can be cut by an arc flash can disintegrate. Conductors

More information

UL248 North American Low Voltage Fuses

UL248 North American Low Voltage Fuses UL248 North American Low Voltage Fuses UL198 : Old low voltage fuse standards UL standards UL248 : New old voltage fuse standards UL512 : Fuse block standards 2/ 23 They establish : UL standards The dimensional

More information

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

FUSES 8.1. Questions? Answers at Western US: CED-ELEV FUSES Western US: -66 CED-ELEV or visit us online at www.cedelevator.com for 24 hour order entry, cross reference data base, product specifications with pictures and much more! Full line catalog available

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.

More information

Application Information Need to know how? You ve turned to the right place...literally.

Application Information Need to know how? You ve turned to the right place...literally. Need to know how? You ve turned to the right place...literally. Your problem: Whether your objective is optimum protection of motor control equipment, power or control transformers, cable wiring, or lighting

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

Low Voltage Fuses For Motor Protection

Low Voltage Fuses For Motor Protection Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.

More information

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

G eneral Purpose Fuses

G eneral Purpose Fuses G eneral Purpose Fuses North American Power Fuses AMP-TRAP2000 AMP-TRAP2000 AJT Class J - Time Delay 1 to 600A - - Motor, motor controller, control transformer, and circuit back-up protection. Space saving

More information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fuseology. Dual-Element, Time-Delay Fuse Operation Dual-Element, Time-Delay Fuse Operation There are many advantages to using these fuses. Unlike single-element fuses, the Cooper Bussmann dual-element, time-delay fuses can be sized closer to provide both

More information

Bussmann. Circuit Protection Solutions

Bussmann. Circuit Protection Solutions ussmann Circuit Protection Solutions ussmann Worldwide Circuit Protection Solutions World s leading supplier of fuses and fusible protection systems, ussmann continues its 88-year history of blazing new

More information

Low voltage, branch circuit fuses

Low voltage, branch circuit fuses Low voltage, branch circuit fuses Contents Description Page Fuse holder and block selection guide -2 Class fuse dimensions -5 Fuses by fuse class Class Fuses Volts CC....... LP-CC............... 600V.....

More information

High Speed Fuses. Section Contents Page

High Speed Fuses. Section Contents Page Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............

More information

Low Voltage, Branch Circuit Rated Fuses

Low Voltage, Branch Circuit Rated Fuses Low Voltage, Branch Circuit Rated Page Fuse Holder & Block Selection Guide 8-20 Class Fuse Dimensions 2-22 By Fuse Class Class Volts Low Voltage Branch Circuit CC...... LP-CC............... 600V..... 23

More information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR400 400A 250V TD Class RK5 Dual Elem Fuse-Fusetron Catalog Number Manufacturer Description Weight per unit Product

More information

E-RATED/MEDIUM VOLTAGE FUSES

E-RATED/MEDIUM VOLTAGE FUSES SRIS -RATD/MDIUM VOLTAG FUSS 5kV, 8kV and 15.5kV Ferrule mounted fuses Amp-trap -rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced clips.

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

The easiest and fastest way to select and specify the right fuse

The easiest and fastest way to select and specify the right fuse Fuses Made Simple BUSSMANN SERIES The easiest and fastest way to select and specify the right fuse Fuse selection made simple Fuses Made Simple with Bussmann series fuses Three tiers of protection help

More information

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in: Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--

More information

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED A240R/A480R/A072F/A072B MED. VOTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of

More information

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings. Ratings Ferraz Shawmut Class H, K and R Fuse Blocks accommodate all Class H, K and R 250 and 600V power fuses. A choice of screw, pressure plate, box and special order stud connectors fit a wide range

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SRIS -RATD / MDIUM VOLTAG FUSS 5kV AND 15kV CLIP-LOCK MOUNTD FUSS Amp-trap -rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as well as

More information

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories ,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker

More information

onlinecomponents.com

onlinecomponents.com 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current

More information

Semiconductor Fuses European Fuses

Semiconductor Fuses European Fuses 66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos

More information

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED A240R/A480R/A072F/A072B MED. VOTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of

More information

Special Purpose Fuses

Special Purpose Fuses 70 series 70 SERIES Color Coded tip Rated 125V AC, 300V DC UL Recognized 125 VAC, 1000A I.R.; 300V DC, 1000A I.R. Guide JDYX2, File E39265 Continuous rated current is 80% of 10 minute (shown in table).

More information

Now - Up To 400A Mains!

Now - Up To 400A Mains! Quik-Spec Family Specification has never been easier or faster for the distribution products you need to achieve selective coordination, and improve electrical system safety and performance Quik-Spec Coordination

More information

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES TELECOMMUNICATIONS SPECIAL PURPOSE FUSES Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment,

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor Reducing Arc Flash Energies on Transformer Secondaries arc flash note 6 By Mike Lang, principal field engineer and Dave Komm, Technical Services Supervisor 1. Introduction Arc flash incident energy calculations

More information

Low-Peak fuses offer the industry s most advanced circuit protection

Low-Peak fuses offer the industry s most advanced circuit protection Low voltage, branch circuit fuses ussmann series Low-Peak fuses offer the industry s most advanced circuit protection Section page Description Fuse holder and block selection guide 2 Fuse reducers ranch

More information

Accessories. For product data sheets, visit

Accessories. For product data sheets, visit British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS

HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS HIGH-SPEED SEMICONDUCTOR FUSES CATALOG POWR-SPEED PRODUCTS HIGH-SPEED FUSES FUSE BLOCKS & HOLDERS MICROSWITCHES FAST-ACTING FUSES NEW PSR Series High-Speed Square-Body Fuses Now available in case sizes

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

ULTRASAFE Fuse Holders The safety evolution continues.

ULTRASAFE Fuse Holders The safety evolution continues. ULTRASAFE Fuse Holders The safety evolution continues. The Revolutionary Advantages Ferraz Shawmut continues to lead the safety evolution with even more improvements to our popular ULTRASAFE fuse holders.

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Application Information

Application Information Application Information Need to know how? You ve turned to the right place...literally. Your problem: Whether your objective is optimum protection of motor control equipment, power or control transformers,

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate Class H, K & R USE LOCKS 250 & 600V CLASS H, K & R USE LOCKS RATINGS: Volts: 250VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 0A, 400A, 600A SCCR: 0kA with class H fuses; 50kA with class K fuses; 0kA with class

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Ferrule fuses. High Speed Fuses

Ferrule fuses. High Speed Fuses Ferrule fuses Table of Contents Basic Catalog Amp Number Volts Range Page FWA 150 5-0 19-193 FWX 50 1-50 19-195 FWH 500 0.5-30 19-199 FWC 00-3 00-01 FWP 90V/700 1-100 0-05 FWK 750 5-0 0-07 FWJ 1000 0-30

More information

Midget & Electronic Fuses

Midget & Electronic Fuses Midget Fuses 50-5 Electronic Fuses 55-59 Automotive Fuses 0-005 Littelfuse POWR-GARD Products Catalog w w w. l i t t e l f u s e. c o m Midget Fuses Supplementary Overcurrent Protection KLK Fuses Fast-Acting

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer Achieving Higher Short Circuit Current Ratings for Industrial Control Panels Standards & codes note 1 By Steve Hansen Sr. Field Engineer Introduction Articles 9.1 and. in the National Electrical Code require

More information

Devices for Branch Circuits and Feeders

Devices for Branch Circuits and Feeders Devices for Branch Circuits and Feeders Branch Circuit Overcurrent Protective Devices and s Fusible Solutions: When selecting fusible overcurrent protective devices, the type of fuse holder or switch is

More information

Specification made simple for selective coordination in a compact size

Specification made simple for selective coordination in a compact size Quik-Spec family of circuit protection solutions BUSSMANN Specification made simple for selective coordination in a compact size SERIES The Quik-Spec Coordination Panelboard (QSCP) simplifies selective

More information

LgD Series Global Pro-tection Fuses 600 Volts AC Time Delay Amperes

LgD Series Global Pro-tection Fuses 600 Volts AC Time Delay Amperes LgD Series Global Pro-tection Fuses 0 Volts AC Time Delay - -00 Amperes The Global Pro system is designed to save valuable space in a crowded panel while providing designers with the flexibility of a universally

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Fuseology. High Speed Fuses

Fuseology. High Speed Fuses Fuseology High Speed Fuses The protection needs for solid-state power equipment often differ from electrical equipment; hence, the high speed fuse evolved. The protection of power diodes and SCRs requires

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Compact Circuit Protector (CCP) Application Note

Compact Circuit Protector (CCP) Application Note Compact Circuit Protector (CCP) Application Note Table Of Contents Application Note Description Page Objective............................................... 3 Compact Circuit Protector (CCP).............................

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Fused Coordination Panelboard

Fused Coordination Panelboard Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined

More information

Fuses Special Purpose

Fuses Special Purpose Square body 700/1300 VAC Very Fast-Acting 63 200 Amperes Description Littelfuse North American style square body semiconductor fuses provide maximum flexibility in equipment design and ultimate protection

More information

Medium voltage fuses Medium voltage fuses

Medium voltage fuses Medium voltage fuses European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor ussmann Introduces the Only Total System Fuse LOW-PEK YELLOW * System Specification grade. The only total system fuse. /0 through 6000 amperes. ain Distribution Switchboard Simplifies selection.,000 ampere

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Solar Combiner Solutions

Solar Combiner Solutions Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments Solar Technology Leading the way in Solar Technology

More information

JARD by MARS JARD by MARS

JARD by MARS JARD by MARS Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6

More information

Equipment Protection. Transformers 600V or Less

Equipment Protection. Transformers 600V or Less Equipment s or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers,

More information

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD BRANCH CIRCUIT PROTECTION FUSED COORDINATION BOARD MERSEN S FUSED COORDINATION BOARD Selective Coordination is required in several locations as defined in the National Electrical Code (NEC). Mersen s Fused

More information

ECET Distribution System Protection. Overcurrent Protection

ECET Distribution System Protection. Overcurrent Protection ECET 4520 Industrial Distribution Systems, Illumination, and the NEC Distribution System Protection Overcurrent Protection One of the most important aspects of distribution system design is system protection.

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

KLKD SERIES 10x38 FUSES

KLKD SERIES 10x38 FUSES KLKD SERIES 0x FUSES 0 Vac/dc /0- A Fast Acting Description The KLKD fuse series is fast-acting with a high DC voltage rating. This family of Midget style fuses (0 x mm) is used in solar combiner boxes

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL) 690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor

More information

JOSLYN CLARK VACUUM CONTACTORS

JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum

More information

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules. Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Harmonization of IEC and North American Safety Standards

Harmonization of IEC and North American Safety Standards Equipment SCCR made easy Harmonization of IEC and North American Safety Standards Dan Neeser Field Application Engineer Eaton s Bussmann Division DanRNeeser@Eaton.com Agenda UL 508C, UL 61800-5-1 and transition

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

FUSE TECHNOLOGY Ambient temperature

FUSE TECHNOLOGY Ambient temperature This fuse technology guide will discuss basic fuse operating, application, and selection criteria concepts. The intended purpose of this section is to aid designers with the operation and characteristics

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information