1 ussmann Circuit Protection Solutions

2 ussmann Worldwide Circuit Protection Solutions World s leading supplier of fuses and fusible protection systems, ussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry s first truly global product line, each item is backed by an efficient worldwide network of distribution, customer service and technical support. ussmann products include the most extensive circuit protection solutions approved for use in a variety of major standards: UL, CS, IEC... Not to mention both European (DIN, ritish Standard) and North merican styled fuses for a wide range of applications: industrial motor protection, power conversion, medium voltage, power distribution, telecommunications network equipment, electronics, and automotive. Manufacturing operations in the U.S., Denmark, and the United Kingdom have earned ISO 9000 certification. ussmann customers are assured of only the utmost quality across every product line. Knowledgeable. Responsive. Customer focused. ussmann continues to set the standard for circuit protection solutions around the world. This catalog is intended to present product data and provide technical information that will help the end user with design application. ussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. ussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications Cooper ussmann Printed in the U.S..

3 Section Guide Page 1 Electrical Power Fuses 1 2 Electronic PC oard and Small Dimension Fuses 29 3 Fuseblocks and Holders 41 4 Disconnect Switches 99 5 High Speed Fuses Medium Voltage Fuses and Fuse Links Telecommunications Protection ritish, European, & Canadian Standard Industrial Fuses Fuse ccessories, Displays, Kits, Etc Fuse Technology 210 Glossary of Terms 231 Index 233 Now you can get current information about ussmann products at anytime, using IF (ussmann Information FX) or visit us on the World Wide Web. ussmann Information Fax ~ ussmann Worldwide Web ~ IF is a simple to use automated fax response system. ll you need is a touchtone telephone and a fax machine to get complete product specifications when you want it. Data sheet numbers are located throughout this catalog. To get a detailed data sheet on the product of your choice, simply dial and request the document number listed. In a matter of minutes a data sheet will be faxed to you. It s that simple. Data sheets can also be downloaded from the Internet. The ussmann web site is continuously updated with our newest products and latest data on circuit protection solutions. Visit us often at Cooper ussmann Printed in U.S.. i

4 General Data Dimensions (Inches) CLSS T T-Tron Fuses JJN (300V) JJS (600V) CLSS J Low-Peak & Limitron Fuses LPJ & JKS (600V) CLSS RK5 & RK1 Fusetron, Low-Peak & Limitron Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R asic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. 250V 600V mpere Ω º Fusetron & Limitron 250V 600V mpere Low-Peak 250V 600V mpere CLSS L Low-Peak & Limitron Fuses KRP-C, KTU, & KLU ( ) (600V) NOTE: KRP-CL (150 to 600) fuses have same dimensions as 601 to 800 case size. KTU (200 to 600) have same dimensions, except tube 3 lgth. 2 dia.; terminal 1fi/ width 1 / thick. 2

5 General Data Dimensions (Millimeters) CLSS T T-Tron Fuses JJN (300V) JJS (600V) CLSS J Low-Peak & Limitron Fuses LPJ & JKS (600V) CLSS RK5 & RK1 Fusetron, Low-Peak & Limitron Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R asic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. 250V 600V mpere Ω º Fusetron & Limitron 250V 600V mpere Low-Peak 250V 600V mpere CLSS L Low-Peak & Limitron Fuses KRP-C, KTU, & KLU ( ) (600V) NOTE: KRP-CL (150 to 600) fuses have same dimensions as 601 to 800 case size. KTU (200 to 600) have same dimensions, except tube 76.2mm lgth. x 50.8mm dia.; terminal 41,3mm width x 31.8mm thick. 3

6 Electrical - Power Fuses T-Tron Very Fast cting, Class T Fuses JJN Very Fast cting mpere Ratings: Voltage Rating: 300Vac (or less), ( Vdc; Vdc) Current Limiting (curves on page 208) Interrupting Rating: 200,000 RMS Sym. (20, Vdc &, Vdc) gency Information: Std , Class T UL Listed, Guide JDDZ, File E4273 CS Certified, Class , File Dimensions: See pages 2-3 for Class T dimensional data. Catalog Numbers JJN-1 JJN-35 JJN-110 JJN-400 JJN-2 JJN-40 JJN-125 JJN-450 JJN-3 JJN-45 JJN-150 JJN-500 JJN-6 JJN-50 JJN-175 JJN-600 JJN-10 JJN-60 JJN-200 JJN-700 JJN-15 JJN-70 JJN-225 JJN-800 JJN-20 JJN-80 JJN-250 JJN-0 JJN-25 JJN-90 JJN-300 JJN-1200 JJN-30 JJN- JJN-350 Carton Quantity and Weight mpere Carton Weight* Ratings Qty. Lbs. Kg *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-0 Vac, Vdc). Refer to Data Sheet: 8002 or contact ussmann pplication Engineering at for more information. JJS Very Fast cting mpere Ratings: Voltage Rating: 600Vac (or less) Current Limiting (curves on page 208) Interrupting Rating: 200,000 RMS Sym. gency Information: Std , Class T UL Listed, Guide JDDZ, File E4273 CS Certified, Class , File Dimensions: See pages 2-3 for Class T dimensional data. Catalog Numbers JJS-1 JJS-30 JJS-90 JJS-250 JJS-2 JJS-35 JJS- JJS-300 JJS-3 JJS-40 JJS-110 JJS-350 JJS-6 JJS-45 JJS-125 JJS-400 JJS-10 JJS-50 JJS-150 JJS-450 JJS-15 JJS-60 JJS-175 JJS-500 JJS-20 JJS-70 JJS-200 JJS-600 JJS-25 JJS-80 JJS-225 JJS-800 Carton Quantity and Weight mpere Carton Weight* Ratings Qty. Lbs. Kg *Weight per carton. Data Sheet: 1025 Data Sheet: 1029 CE logo denotes compliance with European Union Low Voltage Directive (50-0Vac, Vdc). Refer to Data Sheet: 8002 or contact ussmann pplication Engineering at for more information. Recommended fuseblocks/fuseholders for Class T 300V fuses Open fuseblocks - see pages Modular fuseblocks - see page 67 Recommended fuseblocks/fuseholders for Class T 600V fuses Open fuseblocks - see pages Modular fuseblocks - see page 67 For complete specification data, call ussmann Information Fax ~

7 Fuseblocks, Holders and Terminal locks Class T Fuseblocks 300V T300 (300V) For use with Class T Fuses (ussmann JJN) Construction: Glass Polyester, Phenolic on 600, UL Flammability: 94VO Rating: Ω -600 Withstand Rating: 200,000 RMS Sym. gency Information: UL Listed UL512, Guide IZLT, File E14853 CS Certified, Class , File CE logo denotes compliance with European Union Low Voltage Directive (50-0Vac, Vdc). Refer to Data Sheet: 8002 or contact ussmann pplication Engineering at for more information. Dimensional Data Figure 1. Ω to 60 Class T Fuseblocks (300V) Catalog Data Catalog Numbers ox Fig. Wire mps Poles Screw Lug No. Range 2 T SR T CR Ω T SR T CR 1 4 T SR T CR 2 T SR T CR T SR T CR 1 4 T SR T CR 1 T30-1CR SR #10-18 CU CR #6-14 CU-L CR #2-14 CU-L SR #10-18 CU ONLY 61-2 T30-2CR 2 1/0-8 CU-L T30-3CR 1 T C 3 3 T C 4 250kcmil-6 CU-L T C 5 600kcmil-2/0 CU-L T C 6 (2) 600kcmil-4/0 CU-L " 0.16" 0.69" 1.20" X Z " 0.16" 0.91" 2.75" 2.5" 0.91" T30030-S SECTION X-X Class T Fuseblocks (300V) Catalog Numbers lock Dimensions (Inches) Type C T T T T T T X Z 0.44" Full 0.20" Radius C T30060-C SECTION Z-Z Data Sheet: 1115 For complete specification data, call ussmann Information Fax ~

8 Fuseblocks, Holders and Terminal locks Class T Fuseblocks 300V Figure to Figure to " 0.84" 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 1.41" (2 POLE) 2.81" (3 POLE) X Z 1.125" 6" 0.05" 1.25" 2.25" 4.78" 2.25" REF. 0.22" DI. 0.52" C'ORE 0.55" DEEP 1.69" 0.28" DIMETER 0.6 C'ORE 0.5" DEEP X 0.38" 0.75" Z 2.39" 2.56" 1.94" 0.81" 3.06" Figure Figure to " 1.695".996" 6" 1.25" 2.25" 2.75" " 0.28" DIMETER 0.6 C'ORE 0.5" DEEP 1.84" 0.282" DIMETER THRU HOLE 0.625" C'ORE 0.438" DEEP 3.06" 2.38" 2.375" 0.81" 0.625" 4.46" Figure to " 5.75" " 2" 3.44" 0.75" Data Sheet: DIMETER 0.75" C'ORE 0.5" DEEP 60 For complete specification data, call ussmann Information Fax ~

9 Fuseblocks, Holders and Terminal locks Class T Fuseblocks 600V T600 (600V) For use with Class T Fuses (ussmann JJS) Construction: Glass Polyester, Phenolic on 600, UL Flammability: 94VO Rating: Ω -600 Withstand Rating: 200,000 RMS Sym. gency Information: UL Listed UL512, Guide IZLT, File E14853 CS Certified, Class , File Figure 1. Ω to " CE logo denotes compliance with European Union Low Voltage Directive (50-0Vac, Vdc). Refer to Data Sheet: 8002 or contact ussmann pplication Engineering at for more information. 1.44" 1.44" 0.55" " 2.59" 1.16" " Class T Fuseblocks (600V) Catalog Data Catalog Numbers ox Fig. Wire mps Poles Screw Lug No. Range 1 T SR T CR Ω T SR T CR 1 3 T SR T CR 1 T SR T CR T SR T CR 2 3 T SR T CR 1 T60-1C 3.75" 2.31" 0.3 SR #10-18 CU CR #2-14 CU-L CR #2-14 CU-L SR #10-18 CU ONLY 61-2 T60-2C 3 2/0-14 CU-L T60-3C 1 T C * 4 250kcmil-6 CU-L T C 5 600kcmil-2/0 CU-L T C 6 (2) 600kcmil-4/0 CU-L * UL Listed, Guide IZLT, File E14853, CS Certified Class , File 21455M " DIMETER " C'ORE 3.19" " Figure to " 1.75" 1.81" 0.59" " 3.34" " 4.86" 3.06" " " DIMETER 0.5" C'ORE 1.47" Data Sheet: 1116 For complete specification data, call ussmann Information Fax ~

10 Fuseblocks, Holders and Terminal locks Class T Fuseblocks 600V Figure to 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 0.84" 1.41" (2 POLE) 2.81" (3 POLE) X Z 0.78" 0.22" DI. 0.52" C'ORE 0.55" DEEP 2.34" REF. 2.39" X 0.38" 0.75" Z SECTION Z-Z Figure to 200 Figure to 400 6" 0.05" 6" 1.125" 1.25" 2.25" 1.25" 2.25" 2.5" 0.28" DIMETER 0.6 C'ORE 0.5" DEEP " 0.28" DIMETER 0.6 C'ORE 0.5" DEEP 2.72" 2.56" 1.94" 0.81" 3.06" 3.06" 2.38" 0.81" Figure to " 6.75" 2.95" 1.5" 2" 3.44" 0.75" 0.3 DIMETER 0.75" C'ORE 0.5" DEEP Data Sheet: For complete specification data, call ussmann Information Fax ~

11 Time-Current & Current Limitation Curves JJN & JJS, Class T Fuses Time-Current Characteristic Curves verage Melt Time-Current Characteristic Curves verage Melt MPERE RTING MPERE RTING JJN (300V) JJS (600V) 10 TIME IN SECONDS 10 1 TIME IN SECONDS CURRENT IN MPERES 1,000 10, Current Limitation Curves INSTNTNEOUS PEK LET-THRU CURRENT IN MPS RMS SYMMETRICL CURRENT IN MPERES 400,000,000 10,000 1, JJN (300V) 1,000 MPERE RTING RMS SYMMETRICL CURRENTS IN MPERES - = SYMMETRICL VILLE PEK (2.3 x SYMM RMS MPS) 1,000 10,000, ,000 10,000 Current Limitation Curves INSTNTNEOUS PEK LET-THRU CURRENT IN MPS 400,000,000 10,000 1, JJS (600V) 1,000 10,000,000 MPERE RTING , RMS SYMMETRICL CURRENTS IN MPERES =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) 228

12 Glossary of Terms mpere The measurement of intensity of rate of flow of electrons in an electric circuit. n ampere is the amount of current that will flow through a resistance of one ohm under a pressure of one volt. mpere Rating The current-carrying capacity of a fuse. When a fuse is subjected to a current above its ampere rating, it will open the circuit after a predetermined period of time. mpere Squared Seconds, l 2 t The measure of heat energy developed within a circuit during the fuse s clearing. It can be expressed as melting l 2 t, arcing l 2 t or the sum of them as Clearing l 2 t. l stands for effective let-through current (RMS), which is squared, and t stands for time of opening, in seconds. rcing Time The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared. reaking Capacity (See Interrupting Rating) Cartridge Fuse fuse consisting of a current responsive element inside a fuse tube with terminals on both ends. Class CC Fuses 600V, 200,000 interrupting rating, branch circuit fuses with overall dimensions of Ω 1 Ω. Their design incorporates a rejection feature that allows them to be inserted into rejection fuse holders and fuse blocks that reject all lower voltage, lower interrupting rating Ω 1 Ω fuses. They are available from Ω º through 30. Class G Fuses 480V,,000 interrupting rating branch circuit fuses that are size rejecting to eliminate overfusing. The fuse diameter is Ω while the length varies from 1fiΩ to 2 Ω. These are available in ratings from 1 through 60. Class H Fuses 250V and 600V, 10,000 interrupting rating branch circuit fuses that may be renewable or non-renewable. These are available in ampere ratings of 1 amp through 600. Class J Fuses These fuses are rated to interrupt a minimum of 200,000 ac. They are labelled as Current-Limiting, are rated for 600vac, and are not interchangeable with other classes. Class K Fuses These are fuses listed as K-1, K-5, or K-9 fuses. Each subclass has designated I 2 t and l p maximums. These are dimensionally the same as Class H fuses, and they can have interrupting ratings of 50,000,,000, or 200,000. These fuses are current-limiting. However, they are not marked current-limiting on their label since they do not have a rejection feature. Class L Fuses These fuses are rated for 601 through 6000, and are rated to interrupt a minimum of 200,000 ac. They are labelled Current- Limiting and are rated for 600Vac. They are intended to be bolted into their mountings and are not normally used in clips. Some Class L fuses have designed in time-delay features for all purpose use. Class R Fuses These are high performance fuses rated Ω º- 600 in 250V and 600V ratings. ll are marked Current Limiting on their label and all have a minimum of 200,000 interrupting rating. They have identical outline dimensions with the Class H fuses but have a rejection feature which prevents the user from mounting a fuse of lesser capabilities (lower interrupting capacity) when used with special Class R Clips. Class R fuses will fit into either rejection or non-rejection clips. Class T Fuses n industry class of fuses in 300V and 600V ratings from 1 amp through They are physically very small and can be applied where space is at a premium. They are fast acting and time-lag fuses, with an interrupting rating of 200,000 RMS. Classes of Fuses The industry has developed basic physical specifications and electrical performance requirements for fuses with voltage ratings of 600V or less. These are known as standards. If a type of fuse meets the requirements of a standard, it can fall into that class. Typical classes are K, RK1, RK5, G, L, H, T, CC, and J. Clearing Time The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time. Current Limitation fuse operation relating to short circuits only. When a fuse operates in its current-limiting range, it will clear a short circuit in less than Ω cycle. lso, it will limit the instantaneous peak let-through current to a value substantially less than that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance. Dual Element Fuse Fuse with a special design that utilizes two individual elements in series inside the fuse tube. One element, the spring actuated trigger assembly, operates on overloads up to 5-6 times the fuse current rating. The other element, the short circuit section, operates on short circuits up to their interrupting rating. Electrical Load That part of the electrical system which actually uses the energy or does the work required. Fast cting Fuse fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents associated with some electrical loads. Fuse n overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition. High Speed Fuses Fuses with no intentional time-delay in the overload range and designed to open as quickly as possible in the short-circuit range. These fuses are often used to protect solidstate devices. Inductive Load n electrical load which pulls a large amount of current an inrush current when first energized. fter a few cycles or seconds the current settles down to the full-load running current. Interrupting Capacity See Interrupting Rating Interrupting Rating (reaking Capacity) The rating which defines a fuse s ability to safely interrupt and clear short circuits. This rating is much greater than the ampere rating of a fuse. The NEC defines Interrupting Rating as The highest current at rated voltage that an overcurrent protective device is intended to interrupt under standard test conditions. Melting Time The amount of time required to melt the fuse link during a specified overcurrent. (See rcing Time and Clearing Time.) NEC Dimensions These are dimensions once referenced in the National Electrical Code. They are common to Class H and K fuses and provide interchangeability between manufacturers for fuses and fusible equipment of given ampere and voltage ratings. Ohm The unit of measure for electric resistance. n ohm is the amount of resistance that will allow one ampere to flow under a pressure of one volt. 231

Low-Peak fuses offer the industry s most advanced circuit protection

Low-Peak fuses offer the industry s most advanced circuit protection Low voltage, branch circuit fuses ussmann series Low-Peak fuses offer the industry s most advanced circuit protection Section page Description Fuse holder and block selection guide 2 Fuse reducers ranch

More information

Low Voltage, Branch Circuit Rated Fuses

Low Voltage, Branch Circuit Rated Fuses Low Voltage, Branch Circuit Rated Page Fuse Holder & Block Selection Guide 8-20 Class Fuse Dimensions 2-22 By Fuse Class Class Volts Low Voltage Branch Circuit CC...... LP-CC............... 600V..... 23

More information

Low voltage, branch circuit fuses

Low voltage, branch circuit fuses Low voltage, branch circuit fuses Contents Description Page Fuse holder and block selection guide -2 Class fuse dimensions -5 Fuses by fuse class Class Fuses Volts CC....... LP-CC............... 600V.....

More information

General Data Dimensions (Inches) Bussmann

General Data Dimensions (Inches) Bussmann General Data Dimensions (Inches) CLASS T T-Tron Fuses JJN (300V) JJS (600V) CLASS J Low-Peak & Limitron Fuses LPJ & JKS (600V) CLASS RK5 & RK1 Fusetron, Low-Peak & Limitron Fuses (250V & 600V) FRN-R &

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fuseology. Dual-Element, Time-Delay Fuse Operation Dual-Element, Time-Delay Fuse Operation There are many advantages to using these fuses. Unlike single-element fuses, the Cooper Bussmann dual-element, time-delay fuses can be sized closer to provide both

More information

High Speed Fuses. Section Contents Page

High Speed Fuses. Section Contents Page Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor

Main Distribution Switchboard KRP-C_SP LPS-RK_SP KRP-C_SP DP1. Reduced Voltage Starter for Large Motor ussmann Introduces the Only Total System Fuse LOW-PEK YELLOW * System Specification grade. The only total system fuse. /0 through 6000 amperes. ain Distribution Switchboard Simplifies selection.,000 ampere

More information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A

More information

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in: Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--

More information

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating

LO 4 TK 5 LW 7. Item 1. 5 or 6 9 T 10 J 11 FE 12 CK 13 CL 14 G 15 L or 3 17 CP 18. Item 2 SN 19. Ampere Rating ing Devices. Modifications Flex Center Introduction The Safety Flex Center is a special facility at the site of our Cleveland, Tennessee, plant that is dedicated to providing customized safety that meet

More information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR400 400A 250V TD Class RK5 Dual Elem Fuse-Fusetron Catalog Number Manufacturer Description Weight per unit Product

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

Engineering Dependable Protection

Engineering Dependable Protection Electrical Distribution System Engineering Dependable Protection Engineering Dependable Protection - Part II "Selective Coordination of Overcurrent Protective Devices" Table of Contents Page Basic Considerations

More information

www. ElectricalPartManuals. com Engineering Dependable Protection

www. ElectricalPartManuals. com Engineering Dependable Protection Electrical Distribution System Engineering Dependable Protection Engineering Dependable Protection - Part II "Selective Coordination of Overcurrent Protective Devices" Table of Contents Page Basic Considerations

More information

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders Bussmann - Fuse Holders HLQ UL Recognized, Guide IZLT2, File E14853 CSA Certified, Class 6225-01, File 47235 Fuse and knob are an integral one-piece unit. There are no replacement knobs (caps) HLQ carrier

More information

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks Technical Data 09 Effective June 06 Up to 60 A Class R 50 V and 600 V ferrule power distribution fuse blocks Catalog symbols: RM5060-_MW_ RM60030-_MW_ RM60060-_MW_ Features and benefits: Combination power

More information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ

More information

The easiest and fastest way to select and specify the right fuse

The easiest and fastest way to select and specify the right fuse Fuses Made Simple BUSSMANN SERIES The easiest and fastest way to select and specify the right fuse Fuse selection made simple Fuses Made Simple with Bussmann series fuses Three tiers of protection help

More information

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

Ω 1 Ω Supplementary Fuses

Ω 1 Ω Supplementary Fuses Electrical - Power Fuses Ω 1 Ω Supplementary Fuses BAF Fast Acting Ω 1 Ω (10.3mm 38.1mm) Construction: Fibre Tube; Nickel Plated Brass Endcaps Voltage Rating: 250Vac ( Ω º-15A), 125Vac (20-30A) Interrupting

More information

Fuse technology. Application Guide

Fuse technology. Application Guide Circuit Protection Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration,

More information

Bussmann. Fuse Technology

Bussmann. Fuse Technology Fuse Technology Circuit Protection Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments,

More information

Volume 4C: Circuit Protection Bussmann series solutions

Volume 4C: Circuit Protection Bussmann series solutions Volume 4C: Circuit Protection Bussmann series solutions Don't miss a sale or an opportunity to upgrade your fuse protection Three tiers offer distinct levels of circuit protection 1. Ultimate - Unique

More information

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

Equipment Protection. Transformers 600V or Less

Equipment Protection. Transformers 600V or Less Equipment s or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers,

More information

Reduce Downtime With Quick Access to the Right Replacement Fuse

Reduce Downtime With Quick Access to the Right Replacement Fuse Reduce Downtime With Quick Access to the Right Replacement Fuse Section Contents Page Fuse Service Kits Supplemental............................. 506-507 Branch circuit............................. 506-507

More information

Bussmann Services & Application Guide

Bussmann Services & Application Guide Bussmann Services & Application Guide Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Bussmann Services Testing.....................................

More information

Quik-Spec Coordination Panelboard

Quik-Spec Coordination Panelboard Quik-Spec Application Notes Contents Section Page Introduction...................................... Feature/Benefits.................................. Panelboard Overview.............................-

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

UL Recognized power distribution blocks

UL Recognized power distribution blocks Susedes September 2016 example: 16220-3 is a 3-16220 Where: The prefix 16220 defines the block s lineside characteristics (i.e., one conductor that accepts 2/0 - #14 Cu, or 2/0 - #8 Al conductors) and

More information

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Clip Type Fuse Current Rating Fuse Type

More information

Ferrule fuses. High Speed Fuses

Ferrule fuses. High Speed Fuses Ferrule fuses Table of Contents Basic Catalog Amp Number Volts Range Page FWA 150 5-0 19-193 FWX 50 1-50 19-195 FWH 500 0.5-30 19-199 FWC 00-3 00-01 FWP 90V/700 1-100 0-05 FWK 750 5-0 0-07 FWJ 1000 0-30

More information

Products for enhancing electrical safety and reliability

Products for enhancing electrical safety and reliability Circuit protection solutions BUSSMANN Products for enhancing electrical safety and reliability SERIES Advantages of Bussmann series fused circuit protection Bussmann series fuses are worry-free: High interrupting

More information

42.4. Terminal Blocks, Fuse Blocks and Fuse Holders. For Immediate Delivery or Tech Support call KMParts.com at (866)

42.4. Terminal Blocks, Fuse Blocks and Fuse Holders. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Terminal Blocks, Contents Description C383 Series Disconnect Fuse Holders...... C350 Series Fuse Blocks and W Series Fuse Holders.................. Page V7-T-129 V7-T-131 Overview Product Description

More information

Equipment Protection. Listed or Labeled Equipment. Panelboards. Branch Circuit Protection HVAC. Appliances. Supplementary Protection

Equipment Protection. Listed or Labeled Equipment. Panelboards. Branch Circuit Protection HVAC. Appliances. Supplementary Protection Listed or Labeled Equipment Listed or labeled equipment must be installed in accordance with instructions included in the listing or labeling [110.3(B)]. Be sure to observe maximum branch circuit fuse

More information

T CLASS T FUSE BLOCKS

T CLASS T FUSE BLOCKS Ferraz Shawmut Fuse Blocks accommodate fuses up to 600A. Insulators are either of durable, glassfilled polycarbonate (GFPC) or phenolic with verified dielectric strength in excess of 2500V. Ferraz Shawmut

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com LKN200 200A 250V Super-Lag Fuse Link Bussmann Fuses Number Manufacturer Description per

More information

North American Power Fuses

North American Power Fuses North American Power Fuses The most popular North American power fuses to meet the most popular protection priorities. Your problem: Today, you need a time-delay power fuse that can handle normal surges.

More information

Class J modular ferrule and knifeblade fuse blocks

Class J modular ferrule and knifeblade fuse blocks Technical Data10488 SupersedesFebruary 2016 Class J modular ferrule and knifeblade fuse blocks Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with

More information

CUBEFuse. CUBEFuse catalog numbers (amps)

CUBEFuse. CUBEFuse catalog numbers (amps) The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when

More information

Equipment Protection. Transformers 600V or Less

Equipment Protection. Transformers 600V or Less Equipment s or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers,

More information

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block Littelfuse Catalog Number LH600303C Manufacturer Littelfuse Description

More information

BH-1 modular fuse blocks, 700 V, 400 A

BH-1 modular fuse blocks, 700 V, 400 A Supersedes December 1998 Agency information UL Recognized, Guide IZLT2, File E14853 up to 700 V CSA Certified, Class 6225-01, File 47235 up to 700 V CE RoHS compliant Materials Base - light-weight, high

More information

up to 30A limited by conductor size Operating and storage temperature:

up to 30A limited by conductor size Operating and storage temperature: Technical Data 7 USSMNN Effective pril 07 Supersedes December 05 SERIES HE breakaway and non-breakaway in-line fuse holders for UL 3/3 x -/ supplemental fuses Use these part numbers to order insulating

More information

Bussmann series NH catalogue. Leadership in circuit protection

Bussmann series NH catalogue. Leadership in circuit protection Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses... Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive

More information

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature: Technical Data 7 Effective December 05 Supersedes October 05 USSMNN SERIES HE breakaway and non-breakaway in-line fuse holders for UL 3/3 x -/ supplemental fuses Symbol: HE* Description: The ussmann series

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

overvoltage solutions

overvoltage solutions Introduction Contents Innovative overcurrent and overvoltage solutions Fuses Fusible accessories and gear Description Catalog section Selecting fused circuit protection Introduction Low voltage branch

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352 8.3kV E-Rated Description: E-Rated, current-limiting, medium voltage fuses for feeder circuit, switchgear and transformer protection. Supersedes pril 2015 USSMNN SERIES Medium voltage fuses for feeder

More information

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube 5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube Fast-acting, low breaking capacity Optional axial leads available 5 x 20mm physical size Glass tube with silver-plated (32-125mA) and nickel-plated (160mA-10A)

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

Class H & K Fuse Holders - 250/600 Volt

Class H & K Fuse Holders - 250/600 Volt Class H & K - 250/0 Volt Specifications: Approved for 10,000 Amp Withstand Rating and Short Circuit Current Ratings (SCCR) UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant &

More information

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number class T FuseBlocks NEW! Smaller Design Description The new Littelfuse Class T fuse blocks offer many advantages over previous generations that are noted in the features and benets section. Of particular

More information

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards Supersedes July 2018 Quik-Spec Coordination Panelboard 30-400 fusible panelboards Contents Description Page Specifications... 2-3 Enclosure types and voltages/systems.... 4 using, main and feed-through

More information

Harmonization of IEC and North American Safety Standards

Harmonization of IEC and North American Safety Standards Equipment SCCR made easy Harmonization of IEC and North American Safety Standards Dan Neeser Field Application Engineer Eaton s Bussmann Division DanRNeeser@Eaton.com Agenda UL 508C, UL 61800-5-1 and transition

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IEC and ritish Standard fuses 5 Contents ussmann series IEC cylindrical fuses Complete portfolio of 8-22 mm diameter Class am and Class gg cylindrical fuses for industrial applications escription Fuses

More information

Accessories. For product data sheets, visit

Accessories. For product data sheets, visit British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

FUSE TECHNOLOGY Ambient temperature

FUSE TECHNOLOGY Ambient temperature This fuse technology guide will discuss basic fuse operating, application, and selection criteria concepts. The intended purpose of this section is to aid designers with the operation and characteristics

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Selective Coordination

Selective Coordination Introduction and Requirements 5 NEC Code: Definitions 240.12 517.17(B) Healthcare 517.26 Healthcare 620.62 Elevators 700.27 Emergency Systems 701.18 Legally Required Standby Systems What Is Selective Coordination?

More information

North American Power Fuses

North American Power Fuses North American Power Fuses THE MOST POPULAR NORTH AMERICAN POWER FUSES TO MEET THE MOST POPULAR PROTECTION PRIORITIES B Your problem: Today, you need a timedelay power fuse that can handle normal surges.

More information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

Fuseology. Cooper Bussmann Branch Circuit, Low Voltage Power Distribution Fuses. Classes of Fuses. Branch-Circuit Listed Fuses.

Fuseology. Cooper Bussmann Branch Circuit, Low Voltage Power Distribution Fuses. Classes of Fuses. Branch-Circuit Listed Fuses. Cooper Bussmann Branch Circuit, ow Voltage Power istribution Fuses Classes of Fuses Safety is the industry mandate. However, proper selection, overall functional performance and reliability of a product

More information

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES TELECOMMUNICATIONS SPECIAL PURPOSE FUSES Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment,

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

DOWNLOAD OR READ : WHAT FUSES CONTROL THE FUEL PUMP FOR 95 CADILLAC DEVILLE PDF EBOOK EPUB MOBI

DOWNLOAD OR READ : WHAT FUSES CONTROL THE FUEL PUMP FOR 95 CADILLAC DEVILLE PDF EBOOK EPUB MOBI DOWNLOAD OR READ : WHAT FUSES CONTROL THE FUEL PUMP FOR 95 CADILLAC DEVILLE PDF EBOOK EPUB MOBI Page 1 Page 2 what fuses control the fuel pump for 95 cadillac deville what fuses control the pdf what fuses

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses

More information

Cooper Bussmann. Guide. Downtime Reduction, Workplace Safety & Code Compliance. Section Contents

Cooper Bussmann. Guide. Downtime Reduction, Workplace Safety & Code Compliance. Section Contents Cooper Bussmann Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Cooper Bussmann Services Engineering....418 Engineering

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Now - Up To 400A Mains!

Now - Up To 400A Mains! Quik-Spec Family Specification has never been easier or faster for the distribution products you need to achieve selective coordination, and improve electrical system safety and performance Quik-Spec Coordination

More information

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

FUSES 8.1. Questions? Answers at Western US: CED-ELEV FUSES Western US: -66 CED-ELEV or visit us online at www.cedelevator.com for 24 hour order entry, cross reference data base, product specifications with pictures and much more! Full line catalog available

More information

LFJ602003C 200A 600V Fus Block

LFJ602003C 200A 600V Fus Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LFJ602003C 200A 600V Fus Block Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

Fuse holders and blocks

Fuse holders and blocks holders and blocks Section Contents Page OPM-1038 3-pole fuse holders with disconnect switch... 232 OPM-1038 3-pole fuse holders... 233 OPMNGA- 3-pole Class CC and 13 32 X 1 1 2 fuse overcurrent protection

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

UL248 North American Low Voltage Fuses

UL248 North American Low Voltage Fuses UL248 North American Low Voltage Fuses UL198 : Old low voltage fuse standards UL standards UL248 : New old voltage fuse standards UL512 : Fuse block standards 2/ 23 They establish : UL standards The dimensional

More information

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES Class T 300 & 600 Volt use locks USE LOCKS 300 & 600V CLASS T USE LOCKS RATINGS: Volts: 300VAC/DC, 600VAC/DC Amps: 30A, 60A, 00A, 200A, 400A, 600A SCCR: 200kA Mersen Class T fuse blocks accommodate Class

More information

Fuseology. High Speed Fuses

Fuseology. High Speed Fuses Fuseology High Speed Fuses The protection needs for solid-state power equipment often differ from electrical equipment; hence, the high speed fuse evolved. The protection of power diodes and SCRs requires

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

1250/1300 Volt PSC Square Body

1250/1300 Volt PSC Square Body Mersen 1250/1300V PSC square body fuses provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuses are available in four different

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and adaptive technology. This technology is improving

More information

Design Standards NEMA

Design Standards NEMA Design Standards Although several organizations are involved in establishing standards for the design, construction, and application of motor control centers, the primary standards are established by UL,

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Assembly not available for new installations.

Assembly not available for new installations. Catalog Symbol: EP Voltage Ratings: 120/208V, 120/240V, 277/480V Main Device Type: MLO (200A), Main Circuit Breaker (up to 200A) Enclosure: NEMA 1 Trim: Surface Mount Agency Information: UL 67, UL 50 The

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information