Hammond Series 1447SN4 & 1447SN4SS EN4DCS all versions ABB Disconnect Switch. Quality Enclosures. Service Excellence.
|
|
- Randolf Mathews
- 6 years ago
- Views:
Transcription
1 Single Door Enclosures - NEMA 4, 4X Selection Guide Hammond Series 447SN4 & 447SN4SS EN4DCS all versions ABB Switch Flange operated switch (fusible or non-fusible) Shaft: 8-2 dp enclosures, use DSFHS-2; 6 dp enclosures, use DSFHS-7 Controls Handle: DSFHN-HS4 Circuit Breaker Circuit breaker: ABB Operating Mechanism: see ABB chart Shaft: 8-2 dp enclosures, use K7FHD-S2; 6 dp enclosures, use K7FHD-S7 Handle: K7FHD-HS4 Allen Bradley Cutler Hammer General Electric I-T-E Siemens Square D 494V Flange Switch 494V Flange Circuit Breaker Type C36 Switch Type C37 Circuit Breaker C-H Westinghouse Circuit Breaker w/flexshaft Type STDA Flange Switch Type STDA Flange Circuit Breaker Circuit Breaker w/ SpectraFlex Max-Flex Flange Switch Max-Flex Flange Circuit Breaker Class 9422 Switch Class 9422 Circuit Breaker Class 9422 T Switch w/ cable mechanism Circuit Breaker w/cable mechanism switch and operating mechanism: Bulletin 494V Handle: Bulletin 494V-W Connecting rod: 8-0 dp enclosures, use 494V-RA; 2-6 dp enclosures, use 494V-RA2 (except for Hammond part # 447S46L2, use 494V-RB2 (2)) Trailer fuse block kit (if required): Bulletin 494V Fuse kit (if required) Line and load connectors (if required) Circuit breaker: C-H Westinghouse Operating mechanism: Bulletin 494V Handle: Bulletin 494V-W Connecting rod: 8-0 dp enclosures, use 494V-RA; 2-6 dp enclosures, use 494V-RA2 switch and operating mechanism Handle: C36-H2 or H4 Circuit breaker: C-H Westinghouse Operating mechanism Handle: 50 amp, use C37H2 or H4; amp, use C37H6 or H8 Circuit breaker Complete Flex-Shaft handle mechanism switch Type QMR or QMW Handle: STDAX Fuse kit (if required) Variable depth operating mechanism Circuit breaker Handle: STDAX Variable depth operating mechanism Circuit breaker Flange Mt. Handle: amp, use STDAX; SK200, use STDA3X Breaker mounted mechanism. Operating cable switch: MCS Fuse Kit (if required) Handle: Flange mount FHOHS4 Switch operator mechanism Operating cable (standard 36.0 ) Circuit breaker Pressure wire connectors Handle: Flange mount FHOH4 Circuit breaker operator mechanism Operating cable: standard 36 switch and operating mechanism 9422 Handle: 447SN4 use A- or A-2; 447SN4SS use A-2 Circuit breaker Operating mechanism: Class 9422 Handle: 447SN4 use A- or A-2; 447SN4SS use A-2 switch and operating mechanism 9422, Type T Handle: 447SN4 use A- or A-2; 447SN4SS use A-2 Cable mechanism: Class 9422 CFT_O - 3, 5, or 0 foot Circuit breaker: Square D Handle: 447SN4 use A- or A-2; 447SN4SS use A-2 68
2 Single Door Enclosures - NEMA 4, 4X by Note: "K" = 8.62 when "C" = 8.00 "K" =.62 when "C" = 2.00 "P" = Wiring Space s will occupy space on panel shown by dimensions "K", "L" and "M". Wiring space "P" is available when disconnect is installed in the enclosure. *The disconnect information and space occupied tables based on data supplied by disconnect manufacturer s bulletins. Hammond Manufacturing not responsible for dimensional accuracy. ABB Controls ABB Controls Switches (Flange Mounted Operators) ABB Switch Amp Fuse Fuse Clip Number Class OETL-NF30-F 30A No Fuse OETL-NF60-F 60A No Fuse OETL-NF00-F 00A No Fuse OETL-NF75-F 75A No Fuse OETL-NF200-F 200A No Fuse OESA-F30J6-F 30A 30A-600V J OESA-F60J6-F 60A 60A-600V J OESA-F00J6-F 00A 00A-600V J A A available by using non-fusible 200A switch and a trailing fuse block. (consult ABB) ABB Controls Circuit Breakers (Flange Mounted Operators) Amp ABB Mechanism Fuse Type FHD-M 50A D FHF-M 5A-225A E/Q FHF-M 225A Frame FHJ-M 400A J FHM-M 600A L FHM-M 800A M ISOMAX Circuit Amp Operating Breaker Mechanism Fuse Type K=4.75 K=7.09 SN00TL 00A K2FHD-M S S3N50TW 50A K3FHD-M S S3N225TW 225A K3FHD-M S S4N250BW 250A K4FHD-M S S5N400TW 400A K5FHD-M S S6N600TW 600A K6FHD-M S S6N800TW 800A K6FHD-M S Charts reference by Drawing. 69
3 Single Door Enclosures - NEMA 4, 4X Allen Bradley Allen Bradley 494V Switches Alan Bradley Amp Type Number DS30 30A No Fuse DS30 30A 30A-250V H,K,R DS30 30A 30A-600V H,K,R DS30 30A 30A-600V J DS30 30A 60A-250V H,K DS30 30A 60A-600V H,K DS30 30A 60A-600V J DS60 60A No Fuse DS60 60A 60A-250V H,K,R DS60 60A 60A-600V H,K,R DS60 60A 60A-600V J DS60 60A 30A-600V H,K,R DS60 60A 00A-250V H,K DS60 60A 00A-600V H,K DS60 60A 00A-600V J DS00 00A No Fuse DS00 00A 00A-250V H,K,R DS00 00A 00A-600V H,K,R DS00 00A 00A-600V J DS00 00A 60A-600V H,K,R DS00 00A 60A-600V J DS A No Fuse DS A 200A-250V H,K,R DS A 200A-600V H,K,R DS A 200A-600V J DS A 00A-600V H,K,R DS A 00A-600V J Series B 2 "M" dimension does not allow for auxillary switches. Allen Bradley 494V Circuit Breakers Allen Bradley Amp Fuse Type Type No. M40 5A to 50A C-H Westinghouse Circuit Breakers EHD,FD,FDB,FDC,HFD,HMCP M50 70A to 250A C-H Westinghouse Circuit Breakers JD,JDB,JDC,HJD,HMCP M60 00A to 400A C-H Westinghouse Circuit Breakers KD,KDB,DK,HKD,HMCP "M" dimension does not allow for auxiliary switch Charts reference by Drawing. 70
4 Single Door Enclosures - NEMA 4, 4X Cutler Hammer Cutler Hammer C36 Switches Cutler Hammer Amp Type Number C36NC 30A No Fuse C36SC2 30A 30A-250V H, K, R C36SC6 30A 60A-250V H, K, R C36SC6 30A 30A-600V H, J, K, R C36ND 60A No Fuse C36SD22 60A 60A-250V H, K, R C36SD22 60A 30A-600V J C36SD62 60A 30A-600V H, K, R C36SD62 60A 60A-600V J C36NE 00A No Fuse C36SE263 00A 00A-250V H, K, R C36SE263 00A 00A-600V H, K, R C36SE263 00A 00A-600V J , 2 2 C36NF 200A No Fuse , 2 2 C36SF A 200A-250V H, K, R , 2 2 C36SF A 200A-600V H, J, K, R Wire bend space "P" does not allow the use of maximum cable size in 8" deep enclosures A switch should be installed in enclosures with an "A" dimension of 30" or greater. Cutler Hammer C37 Circuit Breaker Operators (C-H Westinghouse Circuit Breakers) Allen Bradley Amp Fuse Type Type No. C37E 50A F Frame EHD,FDB,FD,HFD,FDC C37E 50A F Frame HMCP C37F 250A J Frame JDB,JD,HJD,JDC C37F 250A J Frame HMCP C37F 400A K Frame DK,KDB,KD,HKD C37F 400A K Frame HMCP C37G 600A L Frame LD,HLD,LDC C37G 600A L Frame HMCP Charts reference by Drawing....Cutler Hammer continued on next page 7
5 Single Door Enclosures - NEMA 4, 4X Cutler Hammer cont'd. Cutler Hammer Flex-Shaft Operator Mechanisms (C-H Westinghouse Circuit Breakers) 8 2 Complete Operator Mechansim Amp Fuse Type Breaker Height "X" Breaker Width "Y" FS03 50A F Frame EHD,FDB,FD,HFD,FDC FS03 50A F Frame HMCP F2S03 250A J Frame JDB,JD,HJD,JDC F2S03 250A J Frame HMCP F3S03 400A K Frame DK,KDB,KD,HKD F3S03 400A K Frame HMCP F4S04 600A L Frame LD,HLD,LDC F7S04 800A M Frame MD,MDS F5S04 200A N Frame ND,HND,NDC F6S A R Frame RD,CRD, RDC Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism. The last digit of the part number denotes the shaft length (FS03=3' length). F,J,K frame Flex-Shafts available in 3' to 0' lengths. L,N,R frame Flex-Shafts available in 4' to 6' lengths. By. Flex-Shaft System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-0(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Location "M" from right to left. Charts reference by Drawing. 72
6 Single Door Enclosures - NEMA 4, 4X General Electric General Electric Type STDA Switches General Electric Amp Mechanism For 8 2 Switch L M P P TDOMA 30A No Fuse TDOMA 30A 30A-250V H, R TDOMB 30A 30A-600V H, R TDOMB 30A 60A-250V H, R TDOMB 30A 60A-600V H, R TDOMA 60A No Fuse TDOMB 60A 60A-250V H, R TDOMB 60A 60A-600V H, R TDOMB 60A 00A-250V H, R TDOMB 60A 00A-600V H, R TDOMA 00A No Fuse TDOMB 00A 00A-250V H, R TDOMB 00A 00A-600V H, R TDOMB 00A 200A-250V H, R TDOMB 00A 200A-600V H, R TDOM2 200A No Fuse TDOM2 200A 200A-250V H, R TDOM2 200A 200A-600V H, R Applies to 8" deep enclosures, and is 0.875" less in 2" deep enclosures. General Electric Type STDA Operators For Circuit Breakers General Electric Amp Mechanism For Fuse Type 8 2 Switch L M P P SDOMA 50A TEB, TED, THED SDOMA 50A TEC TDOMB 50A TB TDOMB 50A TEC, TECL TDOMC 50A TEL TDOMD 50A THLC TDOM3 225A TFJ TDOM3 225A TFK, THFK, TFL TDOM4 400A TJJ, TJK4, THJK4, TJL4V TDOM4 600A TJK6, THJK6, TJ4V, TJL4V TDOM5 400A TB4, TJH6S TDOM6 225A TLB2, THLC TDOM6 400A TLB4, THLC SDOMA 50A SPECTRA SE SDOM3 250A SPECTRA SF SDOM4 600A SPECTRA SG Applies to 8" deep enclosures, and is 0.875" less in 2" deep enclosures. Charts reference by Drawing....General Electric continued on next page 73
7 Single Door Enclosures - NEMA 4, 4X General Electric cont'd. General Electric Circuit Breakers (Spectra-Flex Cable Operators) Circuit Breaker Height Circuit Breaker Width Frame Size Max Amp C=8 C=2 "X" "Y" E50 50A SE50 50A SF A SG A SK A Frame Size Breaker Mechanism Flange Mounting Handle Operating Cable 2 E50 SCOMA SCH SC3L SE50/SF250 SCOMEF SCH SC3L SG600 SCOMG SCH SC3L SK200 SCOMK SCH2K SC3H Add "X" for NEMA 4 or NEMA 4X Flange mounting handle. 2 Operating Cables are available 3' to 0' lengths. In the table above, the number "3" in the part number indicates a 3' cable. By. GE Spectra-Flex Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-0(b) for wiring space (Ref "P") needed for line side conductors. 3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Location "M" from right to left. Charts reference by Drawing...see page
8 Single Door Enclosures - NEMA 4, 4X Siemens I-T-E Siemens I-T-E Switches (Max-Flex Operators) Amp Height Width Switch C=8 C=2 "X" "Y" MCS603R 30A No Fuse MCS603R 30A 30A-250V H,K,R MCS603R 30A 30A-600V H,K,R MCS603R 30A 30A-600V J MCS606R 60A No Fuse MCS606R 60A 60A-250V H,K,R MCS606R 60A 60A-600V H,K,R MCS606R 60A 60A-600V J MCS60R 00A No Fuse MCS60R 00A 00A-250V H,K,R MCS60R 00A 00A-600V H,K,R MCS60R 00A 00A-600V J MCS620R 200A No Fuse MCS620R 200A 200A-250V H,K,R MCS620R 200A 200A-600V H,K,R MCS620R 200A 200A-600V J Siemens I-T-E Max-Flex Operators (Circuit Breakers) Complete Operator Mechansim Amp Breaker Frame Size Circuit Breaker Type Circuit Breaker Height "X" Circuit Breaker Width "Y" FHOE036 25A ED ED2,ED4,ED6,HED4,HED6, FHOE036 25A CED CED FHOF A FD FXD6-A,FD6-A,HFD6,FXD6-ETJ,HHFD6, HHFXD6 FHOF A CFD CFD6,CFD6-ETI FHOJ A, 600A JD, LD JXD2,LXD6,JD6,LD6,HJD6,HLD6,HHJD6,HH LD6, HHJXD6,HHLXD6,JXD6-ETI,LXD6-ETI FHOJ A, 600A CJD,CLD CJD6,CLD6,CJD6-ETI,CLD6-ETI FHOLMO36 800A LMD LMD6,LMXD6,HLMD6,HLMDX6,LMXD6-ETI Last three digits of operator mechanism part number denote cable length in inches. 48" cables are offered for ED, FD, JD/LD operators By. I-T-E Max-Flex System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-0(b) for wiring space (Ref P ) needed for line side conductors. 3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex cables. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Location "M" from right to left. Charts reference by Drawing...see page
9 Single Door Enclosures - NEMA 4, 4X Square D Square D Class 9422 Switches Square D Type Amp Number TCN-30 30A No Fuse TCF-30 30A 30A-250V H, K, R TCF-33 30A 30A-600V H, K, R TCF-33 30A 60A-250V H, K, R TCF-33 30A 30A-600V J TDN-60 60A No Fuse TDF-60 60A 30A-600V H, K, R TDF-60 60A 60A-250V H, K, R TDF-63 60A 60A-600V H, K, R TDF-63 60A 60A-600V J TEN-0 00A No Fuse TEF-0 00A 00A-250V H, K, R TEF-0 00A 00A-600V H, K, R TEF-0 00A 00A-600V J TC- 30A No Fuse TC-2 30A 30A-250V H, K, R TC-3 30A 30A-600V H, K, R TC-3 30A 60A-250V H, K, R TC-3 30A 30A-600V J TD- 60A No Fuse TD-2 60A 30A-600V H, K, R TD-2 60A 60A-250V H, K, R TD-3 60A 60A-600V H, K, R TD-3 60A 60A-600V J TE- 00A No Fuse TE-2 00A 00A-250V H, K, R TE-2 00A 00A-600V H, K, R TE-2 00A 00A-600V J TE-3 00A 200A-600V J TF- 200A No Fuse TF-2 200A 200A-250V H, K, R TF-2 200A 200A-600V H, K, R TF-2 200A 200A-600V J TF-3 200A 400A-600V J Square D Class 9422 Variable Depth Operators (Circuit Breakers) General Electric Amp Mechanism For Frame Size 8 2 Switch L M P P RG- 75A GJL RG- 00A GJL RN- 00A FAL,FHL RP- 250A KAL,KHL RR- 400A LAL, LHL, Q4L Charts reference by Drawing. 76
10 Single Door Enclosures - NEMA 4, 4X Square D Square D Class 9422 Switches (Cable Mechanism 9422-CFT30 and 9422A- Handle Mechanism) Square D Type Amp Height Width C=8 C=2 Number "X" "Y" TCN-30 30A No Fuse TCF-30 30A 30A-250V H, K, R TCF-33 30A 30A-600V H, K, R TCF-33 30A 60A-250V H, K, R TCF-33 30A 30A-600V J TDN-60 60A No Fuse TDF-60 60A 30A-600V H, K, R TDF-60 60A 60A-250V H, K, R TDF-63 60A 60A-600V H, K, R TDF-63 60A 60A-600V J TEN-0 00A No Fuse TEF-0 00A 00A-250V H, K, R TEF-0 00A 00A-600V H, K, R TEF-0 00A 00A-600V J Square D Class 9422 Cable Mechanism (Circuit Breakers) Amp Circuit Breaker Circuit Breaker Cable Type Switch Fram Type C=8 C=2 Height "X" Width "Y" 9422 CGJ30 75A GJL CEJ30 00A GJL CFA30 00A FAL,FHL CKA30 250A KAL,KHL CLA30 400A LAL,LHL,Q4L Use cable mechanism with circuit breaker and 9422-A handle mechanism Cable operators are offered in 3, 5, and 0 lengths. Last 2 digits of part numbers above (30) are for 3 cables By Switch. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism. 2. See National Electrical Code 2005 article 430-0(b) for wiring space (Ref P ) needed for line side conductors. 3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius. 4. Space occupied by circuit breaker is calculated by: Overall (Height "X" and Width "Y") Minimum wire bend space (manufacturer specified) Charts reference by Drawing. 77
Disconnect Enclosures
Disconnect Ordering Information ABB Controls Disconnect switch: flange operated switch (fusible or nonfusible) shaft: DSFHS-2 handle: DSFHN-HS4 Circuit breaker: circuit breaker: ABB operating mechanism
More informationTYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS
TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: Finish: Type 4 enclosures are painted ANSI 61 gray polyester powder outside and inside. Type 4X enclosures are unpainted.
More informationUHD Heavy Duty Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D
UHD Heavy Duty Enclosures - NEMA 12 3UHD Shown Application Designed to accept the following dis connect switches and circuit breakers: ABB Controls fl ange mounted variable depth operating mechanisms for
More informationTYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS
TYPE 12 SINGLE DOOR ENCLOSURES FOR FLANGE-MOUNTED DISCONNECTS Construction: 14 gauge steel. Seams are continuously welded and ground smooth. External mounting feet. Door and body stiffeners in larger enclosures
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin A19 (painted steel) Or Hoffman Bulletin A19S (stainless steel) Wall Mounted Disconnect Enclosures Rev.
More informationDisconnect Enclosures
447A Single Door - NEMA, 3 Allen Bradley Inner Panel Included Application Designed to house Allen Bradley 494F flange mounted disconnect switches and 494D flange mounted circuit breaker operators (will
More informationTYPE 12 FREESTANDING DOUBLE DOOR ENCLOSURE FOR FLANGE-
TYPE 12 FREESTANDING DOUBLE DOOR ENCLOSURE FOR FLANGE- MOUNTED DISCONNECT Construction: 10 gauge steel. Seams continuously welded and ground smooth. Body stiffeners in larger enclosures for extra rigidity.
More informationDisconnect Enclosures
40 447A Single Door - NEMA 2, 3... 42-45 UHD Heavy Duty - NEMA 2... 92 447S Single Door - NEMA 2, 3... 47-59 447SN4 Single Door - NEMA 4, 4X... 60 UHD One Door Heavy Duty Disconnect Enclosures - NEMA 2...
More informationFor Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And For Flexible Cable Disconnect Devices In Hoffman Bulletin CWY (painted steel) Or Hoffman Bulletin CWSD (stainless steel) CONCEPT Wall Mounted Disconnect Enclosures
More informationSN4 SERIES ENCLOSURES NEMA 4 FLANGED SINGLE DOOR DISCONNECT
R 6 SN4 SERIES ENCLOSURES NEMA 4 LANGED SINGLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 3, 4, 12, & 13 JIC EL-1-71 UL ile E64791 SN4242108
More informationF20 SSN4X SERIES ENCLOSURES NEMA 4X FLANGED SINGLE DOOR DISCONNECT
R 20 SSN4X SERIES ENCLOSURES NEMA 4X LANED SINLE DOOR DISCONNECT Industry Standards UL 508, Types 4, 4X, 12, & 13 CSA Certified, Types 4 & 12 NEMA/EEMAC Types 4, 4X, 12, & 13 JIC EL-1-71 UL ile E64791
More informationFor Variable Depth Disconnect Devices And Flexible Cable Disconnect Devices
For Variable Depth Disconnect Devices And Flexible Cable Disconnect Devices Hoffman Bulletin WS1D Wall Mount Disconnect Enclosures Rev. B 113357 2005 Hoffman Enclosures Inc. P/N 87577115 87577130 WARNING
More informationAE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets
FMD ENCLOSURES AE Wallmount FMD Enclosures AE Wallmount Carbon Steel Cabinets Superior in design, Rittal's AE flange mounted disconnect enclosures have fewer moving parts, which reduces assembly and installation
More informationDisconnect Enclosures
Wall-Mount Enclosures Type 12 Flange-Mount....................................................................... 296-298 Wall-Mount Enclosures Type 4 & 4X Premier Series 2-Point or 3-Point Locking..........................
More informationF LANGE MOUNT DISCONNECT
F LNGE MOUNT DISCONNECT E Wallmount FMD s... FMD 1-2 NEM 4 Wallmount Boxes... FMD 3-4 NEM 12 Wallmount Boxes... FMD 5-6 TS8 Freestanding FMD s... FMD 7-8 PS Freestanding FMD s... FMD 9-10 Freestanding
More informationDisconnect Enclosures
llen-radley 1494V or 1494U Disconnect Mechanism llen-radley Fuse lip Rating Fuse Mechanism mp lass (when enclosure depth is:) for Switches mp Volt 8 10 12 16 DS30 30 (non) (non) -- 5.75 146 6.37 162 73
More informationDisconnect Enclosures
llen-radley * Do not install s in this depth enclosure. 1494V Disconnect Mechanism llen-radley Fuse lip Rating Fuse Mechanism mp lass (when enclosure depth is:) installed. Fit and function of all equipment
More informationSection 4: Circuit Breaker Enclosures
Section : NEMA Type 1 Enclosures...-2 NEMA Type 3R Enclosures...-3 NEMA Type 12 Enclosures...- NEMA Type /X Enclosures...-5 Hubs and Other Accessories...-6 Dimensions and Outline Drawings...-7 Dimensions
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationELECTRICAL ENCLOSURES AND MODULAR CABINETS EXM MANUFACTURING LTD. Since 1975
www.exmweb.com ELECTRICAL ENCLOSURES AND MODULAR CABINETS 19 EXM MANUFACTURING LTD. Since 1975 NEMA 12-13 SAFETY DISCONNECT 9500 UxD Right flange mounted disconnect multi-door enclosure The 9500 UxD oil
More informationCircuit Breaker Enclosures Section 7 NEMA Type 1
NEMA Type 1 Type 1, Indoor Surface or Flush Mounting NEMA Type 1 THQL, TXQL, THQL-GF 1, 2, 3 70 TQL70F 3 Included TQL70S 3 Included 1, 2, 3 100 TQL100F 3 Included TQL100S 3 Included THQC, THHQC, TXQC 1,
More informationEN4DSC Disconnect Enclosures - NEMA 4 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D
EN4DSC Disconnect Enclosures - NEMA 4 Application Designed to house the following safety disconnect equipment: ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and
More informationCircuit Breaker Enclosures. Section 4.
Circuit Breaker Enclosures Section 4 NEMA Type 1 Enclosures...4-2 NEMA Type 3R Enclosures...4-3 NEMA Type 12 Enclosures...4-4 NEMA Type 4/4X Enclosures...4-5 Hubs and Other Accessories...4-6 Dimensions
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More informationDEH g Installation Instruction for Cable Operator Mechanisms for SE150, SF250, SG600 & SK1200 Spectra RMS Circuit Breakers
DEH-40467 g Installation Instruction for Cable Operator s for SE150, SF250, SG600 & SK1200 Spectra RMS Circuit Breakers Type SRCM1EF, SRCM1G, SRCM1K, Cable Operated Assemblies, Cable Series SC3L-SC10L,
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationSection 3. Molded Case Circuit Breakers.
Molded Case Circuit Breakers Section 3 Industrial Circuit Breakers How to Order...3-2 Features...3-4 Quick Reference Guide...3-5 Q-Line Circuit Breakers Plug-In 120/240V Class...3-11 Plug-In 240V Class...3-13
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More informationBulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled
More informationGE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1
GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,
More informationStandard Product Low Profile Type 12 One-Door Disconnect Enclosures
763.422.2600 Spec-00005 M763.422.2211 Wall-Mount Preferred-Cutout s Low-Profile Type 12 s and Accessories Wall-Mount Preferred-Cutout s Low-Profile Type 12 s and Accessories Low-Profile, One- to Five-Door
More informationThe Total Source for Enclosures and Control Products. Gulf Coast Modification Center
The Total Source for Enclosures and Control Products Gulf Coast Modification Center Harsh and Hazardous Location Products Cordyne, Inc. provides and distributes Hubbell/ Killark products and equipment
More informationTS FMDC. Assembly and operating instructions
TS FMDC 995114 9951145 995115 9951146 995116 9951147 995118 9951148 9951140 9951150 995114 9951151 995114 995115 9951144 9951154 Assembly and operating instructions Table of contents Required Tools Loose
More informationEBMC Combination Line Starters and Enclosures
EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,
More informationRXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Available Models. Automatic Transfer Switch Amps
Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationEvolution Series Switchboards
GE Energy Evolution Series Switchboards Quick Reference imagination at work Main Lug Main Device Width (W) Switchboard Frame Neutral Bus Width (W) Switchboard Frame Neutral Bus Cover 3 A Ground Bar 10
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationSection 7. Circuit Breaker Enclosures. BuyLog Catalog 7-1
NEMA Type 1 Enclosures... 7-2 NEMA Type 3R Enclosures...7-3 NEMA Type 12 Enclosures...7-4 NEMA Type 4/4X Enclosures... 7-5 Hubs and Other Accessories... 7-6 Dimensions and Outline Drawings...7-7 Dimensions
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationIndustrial & Main Breakers
Industrial & Main Breakers American International Marketing P.O. Box 9133 Portland OR 97291-033 Closeout #1285-Industrial-Main-Breakers C25GNF390A 3 Pole 90a Contactor - 120V - Cutler-Hammer C25GNF390A
More informationDISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are
More informationSection 11: Busway. Busway. BuyLog Catalog 11-1 BUSWAY
Section : Busway New from GE! MicroVersaTrip Plus Trip Units with 4WGF protection in bus plugs Joint-Guard Protection System: GE invention dynamically indicates proper torque with color Means easy install
More informationNEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Distribution Equipment NEC/CEC CLASS/ZONE RATED HAZARDOUS
More informationNEMA 4 Single-Door Wall Mount Right-Flanged Disconnect SN4 Series
NEMA 4 Single-Door Wall Mount Right-Flanged Disconnect SN4 Series Applications SN4 Series Designed to house the following: Allen-Bradley Bulletin 1494V disconnect switches with flange-mounted variable
More informationRXT. Model: Model RXT Automatic Transfer Switch
Model: RXT Automatic Transfer Switch -- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationRXT. Model: G (Model RXT Automatic Transfer Switch) Standard Features. Automatic Transfer Switch Amps
Model: RXT Automatic Transfer Switch 100-- Model RXT Automatic Transfer Switch The Model RXT automatic transfer switch is designed for use only with Kohlerr generator sets equipped with RDC2 or DC2 generator
More informationBulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)
Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationBulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)
Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationIndustrial Control & Circuit Breakers
Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide.
More informationBusway Section BuyLog Catalog 13-1
MicroVersaTrip Plus Trip Units with 4WGF protection in bus plugs Joint-Guard Protection System: GE invention dynamically indicates proper torque with color. Means easy installation and easy maintenance!
More informationBulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches
Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationBulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)
Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationGE Energy. GE Panelboards. The right panelboard for any application. imagination at work
GE Energy GE Panelboards The right panelboard for any application imagination at work GE Panelboards Right on design, right on manufacture, right on service From design through manufacture and delivery,
More informationDisconnect Switches Product Guide
Disconnect Switches Product Guide Rotary Switches Non-fused Fused Enclosed Rotary Operating Mechanisms Accessories December 4 Disconnect Switches 1 Manual Motor Disconnect Switches Contents Description
More informationSEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N
SEQUESTR External Disconnect Enclosure Rev. C 2013 Pentair Equipment Protection PH 763 422 2211 hoffmanonline.com P/N 87924206 87924207 SEQUESTR Instruction Table of Contents Hardware Included................................................................
More informationLow Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A
Low Voltage Products Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A Flange Handle Operated Switches Non Fusible 0A - 0A Fusible 0A - 800A 7 Page Shaft operated Cable operated Amp.
More informationContinuous Hinge Clamped Cover Enclosures JN4XHSS Series Stainless Steel Enclosures
JIC Continuous Hinge Clamped Cover Enclosures JN4XHSS Series Enclosures Standard Features panel sold separately) Cover is attached with a continuous stainless steel piano hinge. Design Options Type 304
More informationMolded Case Circuit Breakers Section 6 Q-Line Circuit Breakers
Q-Line Circuit Breakers Accessories 240V Class Terminals (Lugs) for Q-Line Circuit Breakers Ampere Rating Termination Type Wire Range (Cu/Al) Product Number 15-60 Lug (line only) 14-6/12-2 TQAL3A 15-60
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationTransfer switch OT III open or delayed transition, non-automatic
Specification sheet Transfer switch OT III open or delayed transition, non-automatic 40 1000 amp Description The Cummins OTIII non-automatic transfer switch offers flexibility when remote controlled or
More informationQuick selector reference guide. Motor Control Center Aftermarket Buckets
Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview
More informationTechnical Data. Circuit Breakers Motor Circuit Protectors Application 460 Catalog Listings 460
Technical Data Description Page No. Circuit Breakers Motor Circuit Protectors Application 460 Catalog Listings 460 Pressure Connectors (Solderless) 452 Thermal/Magnetic Trip Application/Selection 450,
More informationOPERATOR ADAPTER A21ABA
OPERATOR ADAPTER A21ABA Installation Instructions for Allen Bradley Bulletin 1494F Disconnect Switches And Bulletin 1494D Circuit Breaker Operating Mechanisms (For parts list, see page 2) For floor mounted
More information! WARNING I.L D WARNING GENERAL INFORMATION
C Instructions for Drilling and Assembling Flex Shaft TM Handle Mechanism for L, M, MDL, N, and R-Frame Series C Circuit Breakers, Molded Case Switches, and HMCP s! WARNING DO NOT ATTEMPT TO INSTALL OR
More informationDisconnect Switches and Operating Mechanisms. Section 7.
Disconnect Switches and Operating Mechanisms Section 7 Premium Duty QMW, Heavy Duty QMR Individual Components...7-2 Factory Assembled Fuse Clips...7-4 Handle Operators Product Ordering Tables...7-7 Accessories
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationMolded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3. BuyLog Catalog 3-29
Molded Case Circuit Breakers 15-100A Thermal Magnetic Trip Type TEY/TEYF Noninterchangeable Trip Bolt-on 480Y/277V Class Section 3 Page Updated 09 / 2011 TEY and TEYF breakers are one-inch wide per pole,
More informationNEMA 4 and 12 Ultimate Single-Door Wall Mount Flanged Disconnect N412_CD Series
NEMA 4 and 12 Ultimate Single-Door Wall Mount Flanged Disconnect N412_CD Series Applications N412_CD Series Designed to house the following: AutomationDirect.com NEMA 1/12 Flexible shaft handle for Molded
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationMolded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1
GuardEon Circuit Breakers Overview...6-2 Industrial Circuit Breakers How to Order...6-4 Features...6-6 Quick Reference Guide... 6-8 Q-Line Circuit Breakers Plug-In 120/240V Class...6-16 Plug-In 240V Class...
More informationCircuit Breakers Hazardous
s Hazardous 3C Description Page No. Application/Selection 364 Auxiliary s & s EFD, EFDC Series 382 Thermal Magnetic s & s General Information and Dimensions EPC Series 370, 371 FLB Series 375 EBMB Series
More informationACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX
763.422.26 SPEC-177 B763.422.2211 DISCONNECT SEQUESTR PREFERRED-CUTOUT DISCONNECTS SEQUESTR EXTERNAL DISCONNECTS SEQUESTR PrefERREd-CutoUT DisconnECTS SEQUESTR ExTERnal Disconnects STAINLESS STEEL SEQUESTR
More information1494U Visible-Blade Disconnect Switch
Selection Guide 1494U Visible-Blade Disconnect Switch Bulletin Number 1494U What s Inside Contents Page 1494U Disconnect Switch Components 3 1494U Disconnect Switch Accessories 4 1494U Disconnect Switch
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationSpectra RMS Molded Case Circuit Breakers
GE Consumer & Industrial Electrical Distribution Spectra RMS Molded Case Circuit Breakers imagination at work Contents Pages Spectra RMS at a glance.......................................1 Spectra RMS
More informationwww. ElectricalPartManuals. com Time Current Curves and Outline Drawings Time Current Curves Molded Case Circuit Breakers and Motor Circuit Protectors
Molded Case Circuit Breakers and Motor Circuit Protectors Q-Line THQL AF (15 Amp)...DES-011 THQL AF (20 Amp)...DES-012 THQL GF, THHQL GF (15 Amp) 1...GES-9881 THQL GF, THHQL GF (20 Amp) 1...GES-9882 THQL
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationSection 6. Molded Case Circuit Breakers. BuyLog Catalog 6-1. Section Updated 03 / 2014
Molded Case Circuit Breakers Section Updated 0 / 014 Section 6 Industrial Circuit Breakers How to Order...6- Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 10/40V Class...6-14
More informationand legacy Motor Control Center Aftermarket Renewal Parts Catalog
tiastar TM and legacy Motor Control Center Aftermarket Renewal Parts Catalog Game Changing Innovation www.usa.siemens.com/mcc Answers for industry. Table of Contents Ordering Processes 1-2 Section Parts
More informationdjangoproject.com skillsapp.com for invite)
DATA DESIGN MEANING djangoproject.com skillsapp.com (tweet @skillsapp for invite) VISUALIZATION SRSLY, GUISE DATA? PROFIT MEANING! acquire parse filter mine represent refine interact acquire parse filter
More information1 HP 40 HP. List Price Model Number H W D
Economical Solu ons for Basic Applica ons Siemens s Non Combina on NEMA R Enclosure PACKAGE VARIABLE TORQUE 240V: /4 HP to 60 HP 480V: 1 HP to 200 HP NON COMBINATION NEMA R ❶ 1 HP 200 HP Ra ngs in Stock
More informationFor Options, Modifications and Accessories, see pages Discount Schedule A6
Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F
More information(337) FAX
SECONDCIRCUITS.COM FASTEST LEAD TIMES ON CUSTOM PANELS 1-2 week delivery normal 1 DAY SHIP AVAILABLE UL508A SHOP 1-888-463-2759 (337)785-9343 FAX SALES@SECONDCIRCUITS.COM TABLE OF CONTENTS About Us 3 Rentals
More informationFREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures
118 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST 11 ENCLOSURE Panels (Full & Half Length) For Single-Door Enclosures Panels for single-door enclosures can
More informationStock as of Diversified Ventures (416)
product_code part_no description onhand_qty CUT 10-1308-3 Culter Overload Block 6 CUT 10-1308-5 Culter Overload Block 1 CUT 10250T113 Cutler 30.5mm Green Extended PB Head 1 CUT 10250T1311N Eaton 2-Position
More informationMolded Case Circuit Breakers
Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A
More informationFusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -
disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting
More informationMolded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1
Molded Case Circuit Breakers Section 6 Industrial Circuit Breakers How to Order...6-2 Features...6-4 Quick Reference Guide...6-6 Q-Line Circuit Breakers Plug-In 120/240V Class...6-14 Plug-In 240V Class...6-16
More informationGe 600 Manual Transfer Switch 200 Amp Nema 3r
Ge 600 Manual Transfer Switch 200 Amp Nema 3r Generac offers more options for transfer switches than any other manufacturer. Generac offers a full line of Industrial Transfer Switches to meet varying 100-800,
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationDisconnect Switches and Operating Mechanisms
Disconnect Switches and Operating Mechanisms Section 7 Premium Duty QMW, Heavy Duty QMR Individual Components...7-2 Factory Assembled Fuse Clips...7-4 Handle Operators Product Ordering Tables...7-7 Accessories
More informationLeadership driven by innovation
s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page
More informationPartnership that you can trust. LV Switchgear Motor Control Products.
s Partnership that you can trust LV Switchgear Motor Control Products Maximum etail Price w.e.f. st October, 204 www.siemens.co.in s SIMOCODE pro S Get your motor control center s intelligent and compact
More informationMDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D
MDS Dead-front Padmount Switchgear Style Guide 1VAM224804-SG May 2010 Revision D The MDS style guide aids in the proper selection of your style number. When ordering the MDS, the style number must be given
More informationLighting Panelboards. P2 Panelboards
Lighting Panelboards P2 Panelboards Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factory-assembled options to meet virtually any lighting panel application. The
More informationEylander Electric Inc
Eylander Electric Inc. 1-800-932-8986 To Order Call: 1-800-932-8986 ADVANTAGES OF THE MTS MANUAL TRANSFER 1. THE MOST VERSATILE Assembled from CUTLER-HAMMER CH and BR (old Challenger/Westinghouse), GENERAL
More informationGE Energy Industrial Solutions. Aftermarket Catalog. imagination at work
GE Energy Industrial Solutions Aftermarket Catalog imagination at work Aftermarket Catalog Quick Section Index Aftermarket Catalog Table of Contents 1 Components: Parts 2 Switchgear 3 Motor Control Centers
More informationAudi A4 Current Flow Diagram No. 111 / 1
Page 1 of 9 Audi A4 Current Flow Diagram No. 111 / 1 CAN bus wiring from model year 2006 Notes: For information concerning Edition 10.2006 Position of relays and fuses Multi-pin connections Control units
More information