1 Test Report issued under the responsibility of TEST REORT IEC/EN Audio, Video and Similar Electronic Apparatus: Safety Requirements Report Reference No....: Tested by (name + signature)...: Kenny Ho Witnessed by (name + signature).: Supervised by (name + signature): Approved by (name + signature)..: Sam-Geun, Gwack Date of issue...: 15 May 2009 CB Testing Laboratory Name... : Nemko Hong Kong Ltd. hone: (+852) Address...: Unit 1-5, 15/F, CCT Telecom Building, 11 Wo Shing Street, Fotan, Shatin, Hong Kong Testing location/ procedure...: CBTL RMT SMT WMT TM Testing location/ address...: Applicant s name...: Address...: Same as above. Eastern Frontier Co., Ltd. 13 th FL, BLK B, CHUNG MEI CENTRE, 15 HING YI ST., KWUN TONG, KOWLOON, HONG KONG. Test specification: Standard...: IEC 60065: Amd 1:2005 / EN 60065: A1:2006 Test procedure... : CB Non-standard test method..: Test Report Form No....: Test Report Form(s) Originator... : IECEN 60065G ASTABEAB Master TRF... : Copyright 2006 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo shall be removed This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

2 - age 2 of 48 - Test item description... : Trade Mark...: Switching power supply (direct plug-in adapter with interchangeable or fixed plug) 1),, 2), 3) Manufacturer...: Same as applicant Model/Type reference...: EFS012XXXXYYYYOO (Refer to page 5 for model explanation) Ratings...: AC Input: 0.4A V ac 50/60Hz DC Output: Vdc, max. 2.4A, max. 12W Name and address of production-site (Factory): Eastern Frontier (Shenzhen) Co., Ltd Factory Bldg. #A, Hua Fa Road, Ind. Area, Da Lang Street, Bao An, Shenzhen, China

3 - age 3 of 48 - Copy of marking plate and summary of test results: (Representative) The above label is a draft of an artwork for marking plate pending approval by National certifification bodies and it shall not be affixed to products prior to such an approval

4 - age 4 of 48 - Copy of marking plate and summary of test results: (Representative) The above label is a draft of an artwork for marking plate pending approval by National certifification bodies and it shall not be affixed to products prior to such an approval

5 - age 5 of 48 - General product information: The equipment under tests is Class II switching type power adapter with interchangeable or fixed plug. Trademark: 1), 2), 3) apply for CB certificate only,. 1) applies for both CB and GS certificate. Meaning of symbol XXXXYYYYOO "XXXX" can be "0050" to "0240" to indicate the output voltage, step 0.1V. "0050" means 5.0Vdc; "0240" means 24Vdc. "YYYY" can be "0025" to "0240" to indicate the output current, step 10mA. "0025" means 250mA; "0240" m eans 2400mA; Input rating: Vac, 50/60Hz, 0.4A. OO can be: UL (American plug), EU (Europe plug), K (Korea plug), J (Japan plug), CN (China plug), TW (Taiwan plu g), IN (India plug), ID (Indonesia plug), MY (Malaysia plug), VN (Vietnam plug), TL (Thailand plug) for fixed type plug; CE (Europe, United Kingdom, Australia plug), GS (Europe plug), UK (United Kingdom plug), AU (Australia plug), EM (Europe, United Kingdom plug), KR (Korea plug), AR (Argentina plug), TH (Thailand plug), US (American plug), WW (All replaceable plug mentioned above), A (All asia replaceable plug mentioned above) for replaceable plug. Load condition: refer to page 6. Maximum recommended ambient (Tmra): 45 C The metal which delivers mains fixed in enclosure by plastic with ultra-sonic welding which can not be remove and not affecting to connection with plug part. The plug part fixed on enclosure of adapter by directly slot down and locks automatically. Refer to photos. There are two openings on back side of plug part and size of one opening is 2.6mm by 8.2mm and covered by sliding plastic cover. The openings complied with the requirement of after remove adapter part. The exposed metal on plug part covered by sliding plastic cover after remove adapter. The highest measured temperature on plug hold is 30.3 degree Celsius (Temperature rise) against allowed temperature 60 degree Celsius (Temperature rise) and complied the requirement of limit.

6 - age 6 of 48 - General product information(continued): Load condition Model Name EFS012XXXXYYYYOO Type of equipment Type No. of Transformer Representative DC output Type A EFT A 5Vdc Type B EFT A 6Vdc Type C EFT A 7Vdc Type D EFT A 8Vdc Type E EFT A 8.9Vdc Type F EFT A 9Vdc Type G EFT A 12Vdc Type H EFT A 14Vdc Type I EFT A 16Vdc Type J EFT A 18Vdc Type K EFT A 20.9Vdc Type L EFT A 21Vdc Type M EFT A 24Vdc Different models are identical except model name and the secondary transformer winding number. Weight and dimensions: Fixed plugtype: Mass of equipment: 0.12 kg Dimensions: Max x 42.6 x 29.5 mm Replaceable plug type: Mass of equipment: 0.14 kg Dimensions: Max. 76 x 42.6 x 38 mm

7 - age 7 of 48 - List of attachments: 1) Attachment: Tables to EN/IEC th edition ( 9 pages ) 2) Layout of CB ( 1 page ) 3) Construction of transformer ( 1 page ) 4) hotos ( 12 pages) 5) lug test report ( Test Report No : 12 pages by NEMKO ) 6) National deviations for Argentina, Australia/New Zealand, Canada, United States (USA), Malaysia and Korea.

8 - age 8 of 48 - Test item particulars...: Switching power supply (direct plug-in adapter with interchangeable or fixed plug) Classification of installation and use...: Class II apparatus Supply connection... :... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : ass () - test object does not meet the requirement... : Fail (F) Testing: Date of receipt of test items... : May, 2009 Date(s) of performance of tests... : May, 2009 General remarks: Direct plug in AC adapter The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report, a point is used as the decimal separator. List of test equipment must be kept on file and available for review.

9 - age 9 of 48 - Summary of testing: The equipment under tests is Class II switch mode power supply with direct plug-in. The plug part of the AC/DC adapter in this test report evaluated with EN with EU plug, others plug s hould be checked when marketed in country. External enclosure is plastic material of V-0 grade, and totally enclosed with ultra sonic welding without screws. Circuit characteristics: The equipment contains rimary circuits and Secondary circuits The test result in this report applied the data from worst condition (24Vdc/0.5A) otherwise not specified. EMC compliance with the EMC directive has not been evaluated: compliance with the EMC directive must be evaluated in the countries concerned. Instructions: Instructions/users manual is only in English and German. The information shall be given in a language acceptable to the country where the apparatus is intended to be sold. The sample(s) tested complies with the requirements of IEC 60065: Amd 1:2005 / EN 60065: A1:2006. Compliance with European Special National Conditions, Annex ZB, and A Deviations, Annex ZC, and tested according to national requirements for the following countries: All CENELEC Countries listed in EN 60065: A1:2006 and Argentina, Australia/New Zealand, Canada, Malaysia, United States and Korea.

10 - age 10 of 48-3 GENERAL REQUIREMENTS Safety class of the apparatus... : Class II apparatus. 4 GENERAL CONDITIONS OF TESTS Ventilation instructions require the use of the test box 5 MARKING Comprehensible and easily discernible ermanent durability against water and petroleum spirit 5.1 Identification, maker, model... : On rear side of the enclosure and mass of equipment <7kg Tested with water / spirit 1),, 2), 3) EFS012XXXXYYYYOO Class II symbol if applicable Class II apparatus. Rated supply voltage and symbol... : V~ Frequency if safety dependant 50/60Hz Rated current or power consumption... : 0.4A 5.2 Earth terminal Class II apparatus. Hazardous live terminals Supply output terminals (other than mains) No secondary terminals are live No socket outlet for providing power to other apparatus.

11 - age 11 of Use of triangle with exclamation mark The triangle symbols are used on the circuit diagram for the replaceable safety relevant components. 5.4 Instructions for use User manual information in the following language: German and English Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc. Hazardous live terminals, instructions for wiring The user manual includes information about danger concerning dripping or splashing and objects filled with liquids. No hazardous live terminal. Instructions for replacing lithium battery No lithium battery used. Instructions for modem if fitted None. Class I earth connection warning Class II apparatus. Instructions for multimedia system connection Special stability warning for fixed installation No hazardous live terminal. Warning: battery exposure to heat No lithium battery used. Warning: protective film on CRT face None Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings Instructions for permanently connected equipment Mains plug serve as disconnect device. The apparatus is direct plug AC/DC adapter. Not permanently connected equipment. 6 HAZARDOUS RADIATION 6.1 Ionizing radiation < 36 pa/kg (0,5 mr/h) No ionizing radiation. 6.1 EN European Council Directive 96/29/Euratom of 13 May cm from outer surface of apparatus <1µSv/h (0,1mR/h) 6.2 Laser radiation, emission limits to IEC : No laser radiation Emission limits under fault conditions... :

12 - age 12 of 48-7 HEATING UNDER NORMAL OERATING CONDITIONS 7.1 Temperature rises not exceeding specified values, no operation of fuse links (see appended table) Temperature rise of accessible parts (see appended table) Temperature rise of parts providing electrical insulation Temperature rise of parts acting as a support or as a mechanical barrier (see appended table) (see appended table) Temperature rise of windings (see appended table) arts not subject to a limit under to (see appended table) 7.2 Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current > 0,2 A at least 150 o C No temperatures measured during heating test and fault cond. Tests requires this test (7.2) to be performed. 8 CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE ROTECTION AGAINST ELECTRIC SHOCK 8.1 Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare 8.2 No shock hazard when changing voltage setting device, fuse-links or handling drawers etc. 8.3 Insulation of hazardous live parts not provided by hygroscopic material 8.4 No risk of electric shock following the removal of a cover which can be removed by hand Considered. No changing voltage setting device. No hygroscopic material No cover removable by hand. 8.5 Class I equipment Class II equipment. Basic insulation between hazardous live parts and earthed accessible parts Resistors bridging basic insulation complying with 14.1 a) 8.6 Class II equipment and Class II constructions within Class I equipment No such resistors Class II equipment. Accessible parts separates from hazardous live by double insulation.

13 - age 13 of 48 - Reinforced or double insulation between hazardous live parts and accessible parts Components bridging reinforced or double insulation complying with 14.1 a) or 14.3 Basic and supplementary insulation each being bridged by a capacitor complying with 14.1 a) Reinforced or double insulation being bridged with 2 capacitors in series complying with a) Reinforced or double insulation being bridged with a single capacitor complying with b) Basic insulation bridged by components complying with This clause is void 8.8 Basic or supplementary insulation > 0,4 mm (mm)... : Reinforced insulation > 0,4 mm (mm)... : Thin sheet insulation (excluding non-separable thin sheet insulation. See 8.22) Double / Reinforced insulation complies with requirements specified in clause 10 and 13. Isolating transformer. No such capacitors. No such capacitors. Double/reinforced insulation is bridged by capacitors (CY1). Capacitor separately certified ref. List of Critical Components. None. Insulation sheet between plug pin and CB for basic insulation: min. 0.4 mm thickness 1) Approved sources of opto- couplers are used. All sources provided distance of at least 0.4mm. 2) Thickness of transformer bobbin are min. 0.4mm. 3) Thickness of plastic enclosure between primary components and touchable surface is min. 1.5mm. Thin sheet insulation is applied in the main transformer and between CB soldering side and plug pin.

14 - age 14 of 48 - Basic or supplementary insulation, at least two layers, each meeting 10.3 Basic or supplementary insulation, three layers any two of which meet 10.3 Reinforced insulation, two layers each of which meet 10.3 Two layers applied on outside of transformer to isolate between primary component - core - secondary component. Reinforced insulation, three layers any two which meet Adequate insulation between internal hazardous live conductors and accessible parts No such parts. Double insulated. Adequate insulation between internal hazardous live parts and conductors connected to accessible parts 8.10 Double insulation between conductors connected to the mains and accessible parts. Double insulation between internal hazardous live parts and conductors connected to accessible parts. Conductors safely secured away from hazardous live parts. Double or reinforced insulation Detaching of wires No undue reduction of creepages or clearance distances if wires become detached No wire could become detached. Vibration test carried out... : Refer to This clause is void 8.13 Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s) 8.14 Adequate fastening of covers (pull test 50 N for 10 s) 8.15 No risk of damage to the insulation of internal wiring due to hot parts or sharp edges Adequately fastened. Cover adequately fastened with welding. No risk of damage to the insulation of internal wiring due to high temperature, sharp edges, moving parts or pinches Only special supply equipment can be used Not supplied by a special supply apparatus.

15 - age 15 of Insulated winding wire without additional interleaved insulation TIW with additional interleaved insulation in secondary winding of Transformer T Endurance test as required by 8.17 No such insulation winding is used Disconnection from the mains See below Disconnect device Mains plug. All-pole switch or circuit breaker with >3mm contact separation No switch Mains switch ON indication No switch Switch not fitted in the mains cord 8.21 Bridging components comply with clause 14 No such components Non-separable thin sheet material Not used. 9 ELECTRIC SHOCK HAZARD UNDER NORMAL OERATING CONDITIONS 9.1 Testing on the outside For voltages >1000 V ac or >1500 V dc complies with clause for basic insulation No voltages >1000V ac or >1500V dc a) Open circuit voltages Mains input voltage >35Vac. See below. b) Touch current measured from terminal devices using the network in annex D... : See attachment, Table to EN/IEC th edition. c) Discharge not exceeding 45 μc No part or contact of a terminal with stored voltages between 60V 15kV d) Energy of discharge not exceeding 350 mj No part or contact of a terminal with stored voltages exceeding 15kV Test with test finger and test probe No accesses of hazardous live with the test finger and test probe No hazardous live shafts of knobs, handles or levers Ventilation holes and other holes tested by means of 4 mm x 100 mm test pin No live shafts, handles or levers. No opening.

16 - age 16 of Terminal devices tested with 1 mm x 20 mm test pin (10 N); test probe D of IEC Terminal devices tested with 1 mm x 100 mm straight wire (1 N); test probe D of IEC re-set controls tested with 2.5 mm x 100 mm test pin (10 N); test probe C of IEC No shock hazard due to stored charge on withdrawal of the mains plug; voltage (V) after 2 s... : No access to live parts. No access to live parts. No preset control. <8Vp after 2 sec If C is not greater than 0,1 μf no test needed a) Enclosure sufficiently resistant to external force Test probe 11 of IEC for 10 s (50 N) Test with test finger results in no hazard. b) Test hook of fig. 4 for 10 s (20 N) Test with test hook results in no hazard. c) 30 mm diameter test tool for 5 s (100 or 250 N)... : Test with test tool in enclosure results in no hazard. 9.2 No hazard after removing a cover by hand No cover can be removed by hand. 10 INSULATION REQUIREMENTS 10.1 Insulation resistance (MΩ) at least 2 MΩ min. after surge test for basic and 4 MΩ min. for reinforced insulation... : The measured resistance is >100MΩ for reinforced insulation after surge test performed. Complies with Humidity treatment 48 h or 120 h... : 120h, 90-95%, 30 C No impairment Insulation resistance and dielectric strength between mains teminals Insulation Resistance and dielectric strength across BASIC or SULEMENTARY insulation (Class 1) Insulation resistance and dielectric strength across REINFORCED insulation (Class II) (see appended table) (see appended table)

17 - age 17 of FAULT CONDITIONS 11.1 No shock hazard under fault condition No electric shock hazard under fault conditions 11.2 Heating under fault condition (see appended table 11.2) No hazard from softening solder No solder soften. Flames extinguish within 10 seconds No flame. Soldered terminations not used as protective mechanism No soldered terminations Measurement of temperature rises (see appended table) Temperature rise of accessible parts (see appended table) Temperature rise of parts, other than windings, providing electrical insulation (see appended table) Temperature rise of printed circuit boards (CB) exceeding the limits of table 3 by max. 100 K for max. 5 min a) Temperature rise of printed circuit boards (CB) to , exceeding the limits of table 3 by not more than 100 K for an area not greater than 2 cm² b) Temperature rise of printed circuit boards (CB) to up to 300 K for an area not greater than 2 cm² for a maximum of 5 min Meets all the special conditions if conductors on printed circuit boards are interrupted No area where temperature exceeds 100K above limits No conductors are interrupted/peeled/ loosened during fault conditions. Class I protective earthing maintained Class II apparatus Temperature rise of parts acting as a support or mechanical barrier Temperature rises are within the limits Temperature rise of windings (see appended table) Temperature rise of parts not subject to the limits of to MECHANICAL STRENGTH Bump test where mass >7 kg Mass < 7 kg Vibration test Assessed to be satisfactory constructed.

18 - age 18 of Impact hammer test No damage. Steel ball test No damage Drop test for portable apparatus where mass < 7 kg No damage Thermoplastic enclosures strain relief test No risk of shrinkage or distortion on enclosures 12.2 Fixing of knobs, push buttons, keys and levers No fixing of knobs, push buttons, keys and levers Remote controls with hazardous live parts No cable connected remote control devices Drawers (pull test 50 N, 10 s) No drawers Antenna coaxial sockets providing isolation No antenna Telescoping or rod antennas construction No antenna Telescoping or rod antennas securement No antenna 13 CLEARANCE AND CREEAGE DISTANCES 13.1 Clearances in accordance with 13.3 See attachment: Tables to EN/IEC th edition. Creepage distances in accordance with 13.4 See attachment: Tables to EN/IEC th edition Determination of operating voltage Upper rated supply voltage applied in determining the operating voltage Clearances 2N for internal parts and 30N for enclosures are considered when determining clearances General See attachment: Tables to EN/IEC th edition Circuits conductively connected to the mains comply with table 8 and, where applicable, table Circuits not conductively connected to the mains comply with table 10 See attachment: Tables to EN/IEC th edition. No hazardous secondary voltages Measurement of transient voltages Not measurement Creepage distances See attachment: Tables to EN/IEC th edition.

19 - age 19 of 48 - Creepage distances greater than table 11 minima 13.5 rinted boards Clearances and creepage distances between conductors on printed circuit boards, one of which may be conductively connected to the mains, as in fig Type B coated printed circuit boards complying with IEC (basic insulation only) 13.6 Conductive parts along uncemented joints clearances and creepage distances comply with 13.3 and 13.4 Conductive parts along reliably cemented joints comply with 8.8 No such CB. No type B coated CB. Jointed insulation not applied. Temperature cycle test and dielectric strength test No uncemented joints 13.7 Enclosed, enveloped or hermetically sealed parts: not conductively connected to the mains: clearances and creepage distances as in table arts filled with insulating compound, meeting the requirements of 8.8 For optocouplers, refer to S-c No such parts. 14 COMONENTS 14.1 Resistors a) Resistors between hazardous live parts and accessible metal parts b) Resistors, other than between hazardous live parts and accessible parts Resistors separately approved... : No resistors between hazardous live parts and accessible metal parts. Two bleeder resistors (R1, R2) connected between Live and Neutral, located after fuse. Shorting-circuit or disconnecting of resistor does not cause infringement of the requirement for operation under fault conditions Capacitors and RC units Capacitors separately approved

20 - age 20 of Y capacitors tested to IEC , 2 nd edition : Y1 capacitors (CY1) located between primary and secondary circuitry X capacitors tested to IEC , 2 nd edition : X2 capacitor (CX1), certified according to IEC , 2nd edition Capacitors operating at mains frequency but not connected to the mains: tests for X2... : Capacitors with volume exceeding 1750 mm³, where short-circuit current exceeds 0,2 A: compliance with IEC , 4.38 category B or better... : Capacitors with volume exceeding 1750 mm³, mounted closer to a potential ignition source than table 5 permits: compliance with IEC , 4.38 category B or better... : Shielded by a barrier acc. to / table 21 or metal... : The X-capacitors is certified according to IEC , 2nd edition and E. cap. exceeding 1750 mm³, but metal case The X-capacitors is certified according to IEC , 2nd edition and E. cap. exceeding 1750 mm³, but metal case 14.3 Inductors and windings See below. Comply with IEC , IEC (as relevant) and clause Transformers and inductors marked with manufacturer's name and type... : Transformers and inductors separately approved... : Adequate marking applied General Isolating transformer. Insulation material complies with clause Constructional requirements See below Clearances and creepage distances comply with clause Transformers meet the constructional requirements Class II transformers have adequate separation between hazardous live parts and accessible parts (double or reinforced insulation) No See attachment: Tables to EN/IEC th edition. See attachment: Tables to EN/IEC th edition. Double or reinforced insulation between primary and secondary windings according to clause 8.8.

21 - age 21 of 48 - Coil formers and partition walls > 0,4 mm Thickness: 0.4 mm Class I transformers, with basic insulation and protective screening only if all 7 conditions of are met Separating transformers with at least basic insulation Class II transformers have adequate insulation between hazardous live parts and accessible parts (double or reinforced insulation) Coil formers and partition walls > 0,4 mm Class I transformers have adequate insulation between hazardous live parts and accessible conductive parts or those conductive parts or protective screens connected to a protective earth terminal Winding wires connected to protective earth have adequate current-carrying capacity No such transformer used. Windings of Class II construction. Windings of Class II construction used. Double or reinforced insulation between hazardous live windings and accessible conductive parts. The bobbin: >0.4mm thickness. Windings of Class II construction used. Windings of Class II construction used High voltage components No high voltage components. High-voltage components and assemblies: U > 4 kv (peak) separately approved Component meets category V-1 of IEC High voltage transformers and multipliers tested as part of the submission High voltage assemblies and other parts tested as part of the submission 14.5 rotective devices rotective devices used within their ratings Mains fuse, F1 External clearances and creepage distances meet requirement of clause 13 for the voltage across the device when opened Certified protective devices applied a) Thermal cut-outs separately approved No thermal cut-outs. b) Thermal cut-outs tested as part of the submission a) Thermal links separately approved No thermal links.

22 - age 22 of 48 - b) Thermal links tested as part of the submission Thermal devices re-settable by soldering No such thermal device Fuse-links in the mains circuit according to IEC Correct marking of fuse-links adjacent to holder... : Mains fuse is certified according to IEC The rating of current fuse is marked adjacent in CB: F1 T2AH/250V Not possible to connect fuses in parallel... : Checked by inspection Not possible to touch hazardous live parts when replacing fuse-links without the use of a tool.. : No access to live parts TC-S thermistors comply with IEC None. TC-S devices (15 W) category V-1 or better None Circuit protectors have adequate breaking capacity and their position is correctly marked No such components Switches No switch a) Separate testing to IEC including: operations Normal pollution suitability Resistance to heat and fire level 3 and Make and break speed independent of speed of actuation V-0 compliance with annex G, G b) Tested in the apparatus: Switch controlling > 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with , and V-0 in annex G, G.1.1 Switch controlling > 0.2A with open contact voltage < 35 V (peak)/24 V dc complying with and V-0 in annex G, G.1.1 Switch controlling < 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with and V-0 in annex G, G Switch tested to b) constructed to IEC subclause 13.1 and has making/breaking action independent of speed of actuation Switch tested to b) compliant with IEC subclause d) and m) not attaining excessive temperatures in use

23 - age 23 of Switch tested to b) has adequate dielectric strength Mains switch controlling mains socket outlets additional tests to IEC Socket outlet current marking correct 14.7 Safety interlocks No safety interlocks. Safety interlocks to 2.8 of IEC Voltage setting devices and the like No voltage setting devices. Voltage setting device not likely to be changed accidentally 14.9 Motors No motors Endurance test on motors Motor start test Dielectric strength test Not adversely affected by oil or grease etc rotection against moving parts Motors with phase-shifting capacitors, threephase motors and series motors meet clause. B.8, B.9 and B.10 of IEC 60950, Annex B Batteries No batteries Batteries mounted with no risk of accumulation of flammable gases No possibility of recharging non-rechargeable batteries Recharging currents and times within manufacturers limits Lithium batteries discharge and reverse currents within the manufacturers limits No lithium battery Battery mould stress relief No special battery Battery drop test No special battery Optocouplers Optocouplers comply with Cl. 8 Separately certified. (See append table).

24 - age 24 of 48 - Internal and external dimensions to or alternatively 13.6 (jointed insulation) (See append table) Surge suppression varistors Varistor MOV1 located on mains circuit (after fuse). Comply with IEC Not connected between mains and accessible parts except for earthed parts of permanently connected apparatus Complies with the current pulse, fire hazard and thermal stress requirements of TERMINALS Mains plug, appliance inlet, interconnection couplers and mains socket-outlet meet the appropriate standard Overloading of plugs or appliance inlets prevented if the apparatus has mains socket outlets Overloading of internal wiring prevented if the apparatus has mains socket outlets The apparatus is direct plug AC/DC adapter. See summary of testing. Not provide mains socket outlets to other apparatus Connectors for antenna, earth, audio, video or data: No risk of insertion in mains socket-outlets No risk of insertion into audio or video: outlets marked with the symbol of 5.2 Output connector is so designed that insertion into mains socket-outlet is unlikely to occur. No sockets indicated with the symbol Output terminals of a.c. adaptors or similar devices not compatible with household mains socket-outlets Adapter has standard adapter output plug not compatible with those specified for household and similar general purpose rovision for protective earthing Accessible conductive parts of Class I equipment reliably connected to earth terminal, within equipment Class II apparatus.

25 - age 25 of 48 - rotective earth conductors correctly coloured Equipment with non-detachable mains cord provided with separate protective earth terminal near mains input rotective earth terminal resistant to corrosion Earth resistance test: < 0,1 Ω at 25 A... : 15.3 Terminals for external flexible cords and for permanent connection to the mains supply Adequate terminals for connection of permanent wiring The apparatus is direct plug AC/DC adapter. Apparatus is not for permanent connection Reliable connection of non-detachable cords: AC main plug provided. Not soldered to conductors of a printed circuit board Adequate clearances and creepage distances between connections should a wire break away Wire secured by additional means to the conductor Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar Soldered conductors wrapped around terminal prior to soldering or held in place by additional means Clamping of conductor and insulation if not soldered or held by screws Terminals allow connection of appropriate crosssectional area of conductors, for the rated current of the equipment No screws and nuts clamping conductors used Terminals to have sizes required by table Terminals clamp conductors between metal and have adequate pressure Terminals designed to avoid conductor slipping out when tightened or loosened Terminals adequately fixed to avoid loosening when the clamping is tightened or loosened and stress on internal wiring is avoided No terminals clamp conductors

26 - age 26 of Terminals carrying a current more than 0,2 A: contact pressure not transmitted by insulating material except ceramic Termination of non-detachable cords: wires terminated near to each other Terminals located and shielded: test with 8 mm strand 15.4 Devices forming a part of the mains plug The AC/DC adapters provided with device forming a part of the mains plug. See summary of testing, also No undue strain on mains socket-outlets The torque not exceeds 0.25Nm Device complies with standard for dimensions of mains plugs Device has adequate mechanical strength (tests a,b,c) 16 EXTERNAL FLEXIBLE CORDS 16.1 Mains cords sheathed type, complying with IEC for VC or IEC for synthetic rubber cords... : Non-detachable cords for Class I have green/yellow core for protective earth 16.2 Mains cords conductors have adequate crosssectional area for rated current consumption of the equipment 16.3 a) Flexible cords not complying with 16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength Complied with relevant standard. See summary of testing, also. Complied with the requirement of this standard after drop test. Not turn at torque of 0.4Nm. No displaced by more than 1mm after apply pull force 40N. The apparatus is direct plug AC/DC adapter. Class II apparatus No interconnecting cables comprising hazardous live conductors.

27 - age 27 of 48 - b) Flexible cords not complying with 16.1, withstand bending and mechanical stress (3.2 of IEC ) 16.4 Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions 16.5 Adequate strain relief on external flexible cords Not possible to push cord back into equipment Strain relief device unlikely to damage flexible cord For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor 16.6 Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use 16.7 Transportable musical instruments and amplifiers fitted with detachable cord set with appliance inlet to IEC Transportable musical instruments and amplifiers fitted with detachable cord sets or with means of stowage to protect the cord Class II apparatus The apparatus is not a transportable musical instrument and amplifier 17 ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 17.1 Torque test to table 20: No screw used. - screws into metal: 5 times - screws into non-metallic material: 10 times 17.2 Correct introduction into female threads in nonmetallic material 17.3 Cover fixing screws: captive Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter 17.4 No loosening of conductive parts carrying a current > 0,2 A Adequately secured.

28 - age 28 of Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0,2 A 17.6 Stranded conductors of flexible supply cords carrying a current > 0,2 A with screw terminals not consolidated by solder 17.7 Cover fixing devices other than screws have adequate strength and their positioning is unambiguous 17.8 Fixing devices for detachable legs or stands provided 17.9 Internal pluggable connections, affecting safety, unlikely to become disconnected No contact pressure transmitted through insulating material. The apparatus is direct plug AC/DC adapter. Adequately secured. No detachable legs or stands provided. No internal pluggable connection. 18 MECHANICAL STRENGTH OF ICTURE TUBES AND ROTECTION AGAINST THE EFFECTS OF IMLOSION icture tube separately approved to IEC 61965: No CRT in the equipment. icture tube separately approved to icture tubes > 16 cm intrinsically protected Non-intrinsically protected tubes > 16 cm used with protective screen rotective film as part of implosion protection: edges covered by enclosure 18.2 Intrinsically protected tubes: tests on 12 samples Samples subject to ageing: Samples subject to implosion test: Samples subject to mechanical strength test (steel ball): Non-intrinsically protected tubes tested to STABILITY AND MECHANICAL HAZARDS Mass of the equipment exceeding 7 kg... : <7 Kg Apparatus intended to be fastened in place suitable instructions 19.1 Test on a plane, inclined at 10 o to the horizontal N force applied vertically downwards

29 - age 29 of N force, or 13% of weight, applied horizontally to point of least stability Edges or corners not hazardous There are no hazardous edges or corners when the apparatus is operating in normal position Glass surfaces (exc.laminated) with an area exceeding 0,1 m² or maximum dimension > 450 mm, pass the test of No glass surface Wall or ceiling mountings adequate Not for wall or ceiling mounting. 20 RESISTANCE TO FIRE 20.1 Electrical components and mechanical parts a) Exemption for components contained in an enclosure of material V-0 to IEC with openings not exceeding 1 mm in width b) Exemption for small components as defined in Electrical components meet the requirements of Clause 14 or Insulation of internal wiring working at voltages > 4 Kv or leaving an internal fire enclosure, or located within the areas mentioned in Table 21, not contributing to the spread of fire Material of printed circuit boards on which the available power exceeds 15 W at a voltage between 50 V and 400 V (peak) a.c. or d.c. meets V-1 or better to IEC60707, unless used in a fire enclosure Material of printed circuit boards on which the available power exceeds 15 W at a voltage >400 V (peak) a.c. or d.c. meets V-0 to IEC CB is of flammability class V-0, and exception is made for small components. Electrical components comply with flammability requirements in clause 14. No wires working at voltages> 4kV or leaving an internal fire enclosure. CB complies with V-0 or better. CB complies with V-0 or better.

30 - age 30 of Components and parts not covered by , and (other than fire enclosures) mounted nearer to a potential ignition source than the distances in Table 21 comply with the relevant flammability category in Table 21 Components and parts as above but shielded from a potential ignition source, with the barrier area in accordance with Table 21 and fig. 13 Apparatus with voltages >4kV under normal operating conditions and distances to the enclosure exceed those specified Table 21, flammability classification HB40 or better is required for the enclosure. The bobbins of transformer and line filter are of min. flammability class V Fire enclosure otential ignition sources with open circuit voltage > 4 kv (peak) a.c. or d.c. contained in a fire enclosure to V-1 No voltage exceeding 4 kv, no fire enclosure requirement Internal fire enclosures with openings not exceeding 1 mm in width and with openings for wires completely filled Requirements of and met by an internal fire enclosure No internal fire enclosure. No internal fire enclosure.

31 - age 31 of 48 - A A.5.1 A AENDIX A, ADDITIONAL REQUIREMENTS FOR AARATUS WITH ROTECTION AGAINST SLASHING WATER j) Marked with IX4 (IEC 60529), a) does not apply Enclosure provides protection against splashing water Not intended for outdoor use. A Humidity treatment carried out for 7 days B AENDIX B, AARATUS TO BE CONNECTED TO THE TELECOMMUNICATION NETWORKS Complies with IEC clause 1 Complies with IEC clause 2 Complies with IEC clause 3 but with modified to of this standard Complies with IEC clause 4 but with 4.1.2, and modified in accordance with annex B of this standard Complies with IEC cause 5 but with modified in accordance with annex B of this standard Complies with IEC clause 6 Complies with IEC clause 7 Complies with IEC annex A, B and C Not intended for telecommunication networks. L AENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH AARATUS FOR HOTOGRAHIC UROSES. L5.4 Marking and Instructions Not contains electronic flash circuit. L9.1.1 L7.1.5 & L L Terminals to connection to synchroniser not HAZARDOUS LIVE Lithium batteries meet permissible temp rise in Table 3, unless comply with of IEC Mains switch characteristics appropriate to its function under normal conditions

32 - age 32 of TABLE: temperature rise measurements ower consumption in the OFF/Stand-by No stand-by function osition of the functional switch (W)... : Operating conditions Un (V) In (A) n (W) out (W) For output model: EFS OO 90/50Hz Vdc, 2.4A 90/60Hz Vdc, 2.4A 100/50Hz Vdc, 2.4A 100/60Hz Vdc, 2.4A 240/50Hz Vdc, 2.4A 240/60Hz Vdc, 2.4A 254/50Hz Vdc, 2.4A 254/60Hz Vdc, 2.4A 264/50Hz Vdc, 2.4A 264/60Hz Vdc, 2.4A For model: EFS OO 90/50Hz Vdc, 2A 90/60Hz Vdc, 2A 100/50Hz Vdc, 2A 100/60Hz Vdc, 2A 240/50Hz Vdc, 2A 240/60Hz Vdc, 2A 254/50Hz Vdc, 2A 254/60Hz Vdc, 2A 264/50Hz Vdc, 2A 264/60Hz Vdc, 2A For model: EFS OO 90/50Hz Vdc, 1.71A 90/60Hz Vdc, 1.71A 100/50Hz Vdc, 1.71A 100/60Hz Vdc, 1.71A 240/50Hz Vdc, 1.71A 240/60Hz Vdc, 1.71A

33 - age 33 of 48 - Operating conditions Un (V) In (A) n (W) out (W) 254/50Hz Vdc, 1.71A 254/60Hz Vdc, 1.71A 264/50Hz Vdc, 1.71A 264/60Hz Vdc, 1.71A For model: EFS OO 90/50Hz Vdc, 1.5A 90/60Hz Vdc, 1.5A 100/50Hz Vdc, 1.5A 100/60Hz Vdc, 1.5A 240/50Hz Vdc, 1.5A 240/60Hz Vdc, 1.5A 254/50Hz Vdc, 1.5A 254/60Hz Vdc, 1.5A 264/50Hz Vdc, 1.5A 264/60Hz Vdc, 1.5A For model: EFS OO 90/50Hz Vdc, 1.34A 90/60Hz Vdc, 1.34A 100/50Hz Vdc, 1.34A 100/60Hz Vdc, 1.34A 240/50Hz Vdc, 1.34A 240/60Hz Vdc, 1.34A 254/50Hz Vdc, 1.34A 254/60Hz Vdc, 1.34A 264/50Hz Vdc, 1.34A 264/60Hz Vdc, 1.34A For model: EFS OO 90/50Hz Vdc, 1.33A 90/60Hz Vdc, 1.33A 100/50Hz Vdc, 1.33A 100/60Hz Vdc, 1.33A 240/50Hz Vdc, 1.33A

34 - age 34 of 48 - Operating conditions Un (V) In (A) n (W) out (W) 240/60Hz Vdc, 1.33A 254/50Hz Vdc, 1.33A 254/60Hz Vdc, 1.33A 264/50Hz Vdc, 1.33A 264/60Hz Vdc, 1.33A For model: EFS OO 90/50Hz Vdc, 1A 90/60Hz Vdc, 1A 100/50Hz Vdc, 1A 100/60Hz Vdc, 1A 240/50Hz Vdc, 1A 240/60Hz Vdc, 1A 254/50Hz Vdc, 1A 254/60Hz Vdc, 1A 264/50Hz Vdc, 1A 264/60Hz Vdc, 1A For model: EFS OO 90/50Hz Vdc, 0.85A 90/60Hz Vdc, 0.85A 100/50Hz Vdc, 0.85A 100/60Hz Vdc, 0.85A 240/50Hz Vdc, 0.85A 240/60Hz Vdc, 0.85A 254/50Hz Vdc, 0.85A 254/60Hz Vdc, 0.85A 264/50Hz Vdc, 0.85A 264/60Hz Vdc, 0.85A For model: EFS OO 90/50Hz Vdc, 0.85A 90/60Hz Vdc, 0.85A 100/50Hz Vdc, 0.85A 100/60Hz Vdc, 0.85A

35 - age 35 of 48 - Operating conditions Un (V) In (A) n (W) out (W) 240/50Hz Vdc, 0.85A 240/60Hz Vdc, 0.85A 254/50Hz Vdc, 0.85A 254/60Hz Vdc, 0.85A 264/50Hz Vdc, 0.85A 264/60Hz Vdc, 0.85A For model: EFS OO 90/50Hz Vdc, 0.85A 90/60Hz Vdc, 0.85A 100/50Hz Vdc, 0.85A 100/60Hz Vdc, 0.85A 240/50Hz Vdc, 0.85A 240/60Hz Vdc, 0.85A 254/50Hz Vdc, 0.85A 254/60Hz Vdc, 0.85A 264/50Hz Vdc, 0.85A 264/60Hz Vdc, 0.85A For model: EFS OO 90/50Hz Vdc, 0.75A 90/60Hz Vdc, 0.75A 100/50Hz Vdc, 0.75A 100/60Hz Vdc, 0.75A 240/50Hz Vdc, 0.75A 240/60Hz Vdc, 0.75A 254/50Hz Vdc, 0.75A 254/60Hz Vdc, 0.75A 264/50Hz Vdc, 0.75A 264/60Hz Vdc, 0.75A For model: EFS OO 90/50Hz Vdc, 0.67A 90/60Hz Vdc, 0.67A 100/50Hz Vdc, 0.67A

36 - age 36 of 48 - Operating conditions Un (V) In (A) n (W) out (W) 100/60Hz Vdc, 0.67A 240/50Hz Vdc, 0.67A 240/60Hz Vdc, 0.67A 254/50Hz Vdc, 0.67A 254/60Hz Vdc, 0.67A 264/50Hz Vdc, 0.67A 264/60Hz Vdc, 0.67A For model: EFS OO 90/50Hz Vdc, 0.57A 90/60Hz Vdc, 0.57A 100/50Hz Vdc, 0.57A 100/60Hz Vdc, 0.57A 240/50Hz Vdc, 0.57A 240/60Hz Vdc, 0.57A 254/50Hz Vdc, 0.57A 254/60Hz Vdc, 0.57A 264/50Hz Vdc, 0.57A 264/60Hz Vdc, 0.57A For model: EFS OO 90/50Hz Vdc, 0.57A 90/60Hz Vdc, 0.57A 100/50Hz Vdc, 0.57A 100/60Hz Vdc, 0.57A 240/50Hz Vdc, 0.57A 240/60Hz Vdc, 0.57A 254/50Hz Vdc, 0.57A 254/60Hz Vdc, 0.57A 264/50Hz Vdc, 0.57A 264/60Hz Vdc, 0.57A For model: EFS OO 90/50Hz Vdc, 0.5A 90/60Hz Vdc, 0.5A

37 - age 37 of 48 - Operating conditions Un (V) In (A) n (W) out (W) 100/50Hz Vdc, 0.5A 100/60Hz Vdc, 0.5A 240/50Hz Vdc, 0.5A 240/60Hz Vdc, 0.5A 254/50Hz Vdc, 0.5A 254/60Hz Vdc, 0.5A 264/50Hz Vdc, 0.5A 264/60Hz Vdc, 0.5A

38 - age 38 of TABLE: temperature rise measurements Monitored point: Loudspeaker impedance (Ω)... : Several loudspeaker systems Marking of loudspeaker terminals 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information **) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K)

39 - age 39 of TABLE: temperature rise measurements(continued) Monitored point: 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information **) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K)

40 - age 40 of TABLE: temperature rise measurements(continued) Monitored point: 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information *) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K)

41 - age 41 of TABLE: temperature rise measurements(continued) Monitored point: 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information *) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K) (K)

42 - age 42 of TABLE: temperature rise measurements(continued) Monitored point: 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information *) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K) (K)

43 - age 43 of TABLE: temperature rise measurements(continued) Monitored point: 90V/ 60Hz Horizonta l 90V/ 60Hz Vertical dt (K) 264V/ 50Hz Horizonta l 264V/ 50Hz Vertical For model: EFS OO 1.T1 coil **) 2.T1 core **) 3.lug near L Input wire CB near D L1 coil **) 7.CX1 body CB near MOV C1 body CB near IC CY1 body IC2 body CB near D L2 coil **) 15.C11 body L3 coil **) 17.Output wire Internal enclosure near T Outer enclosure near T Ambient Supplementary information *) Minus (-) 10K applied for thermo-couple method for windings Limit dt (K) (K)

44 - age 44 of TABLE: softening temperature of thermoplastics Temperature T of part T - normal conditions ( o C) T - fault conditions ( o C) Min T softening ( o C) supplementary information: 10.3 TABLE: insulation resistance measurements Insulation resistance R between: R (MΩ) Required R (MΩ) Between mains poles (primary fuse disconnected) (Basic insulation) >100 2 Mylar sheet (Basic insulation) >100 2 oles of supply and output terminals (Reinforced insulation) >100 4 oles of supply and the plastic enclosure with metal foil (Reinforced insulation) Transformer T1 primary winding and secondary winding (Reinforced insulation) Transformer T1 secondary winding and core (Reinforced insulation) 2 layers of insulated tape surround T1 (tested with 1 layer) (Reinforced insulaton) >100 4 >100 4 >100 4 > TABLE: electric strength measurements Test voltage applied between: Test voltage (V) Breakdown Between mains poles (primary fuse disconnected) (Basic insulation) 1500 No Mylar sheet (Basic insulation) 1500 No oles of supply and output terminals (Reinforced insulation) 3000 No oles of supply and the plastic enclosure with metal foil (Reinforced insulation) Transformer T1 primary winding and secondary winding (Reinforced insulation) Transformer T1 secondary winding and core (Reinforced insulation) 2 layers of insulated tape surround T1 (tested with 1 layer) (Reinforced insulaton) 3000 No 3000 No 3000 No 3000 No

45 - age 45 of TABLE: summary of fault condition tests component No. Voltage (V) 0,9 or 1,1 times rated voltage... : 90 or 264 Ambient temperature ( o C)... : 25, if not specify fault test voltage (V) test time fuse No. fuse current (A) result D2 S-c 264 1sec. F1 * Fuse F1 opened immediately. No hazards. C1 S-c 264 1sec. F1 * Fuse F1 opened immediately. No hazards. IC2 pin 1-2 S-c min. F Unit shut down. No hazards. IC2 pin 1 O-c min. F IC2 pin 3-4 S-c min. F IC2 pin 3 O-c min. F D8 S-c min. F Unit shut down. No hazards. Unit shut down. No hazards. Unit shut down. No hazards. Unit shut down. No hazards. T1 pin 1-3 S-c min. F Unit shut down. No hazards. T1 pin 2-5 S-c min. F Unit shut down. No hazards. T1 pin 9-10 S-c min. F Unit shut down. No hazards. Output S-c min. F Unit shut down. No hazards. IC1 pin 2-5 S-c 264 1sec. F1 * Fuse F1 opened immediately. No hazards. IC1 pin 2-7 S-c min. F Unit shut down. No hazards. For output model: EFS OO

46 - age 46 of 48 - Output O-l h F Output loaded to 3.1A. Max. temp.at T1coil=105.7 C, T=79K; T1core=107.5 C, T=80.8K ; lug near L=41.5 C, T=14.8K; Input wire=47.8 C, T=21.1K ; CB near D2=59.5 C, T=32.8K CB near MOV =51.6 C, T=24.9K; CB near IC1=108.9 C, T=82.2K ; CY1 body=93.3 C, T=66.6K; IC2 body=80.3 C, T=53.6K ; CB near D8=110.7 C, T=84K; Output wire=76.3 C, T=49.6K; Internal enclosure near T1=71.5 C, T=44.8K; Outer enclosure near T1=58.9 C, T=32.2K ; Ambient=26.7 C No hazard, No damaged. Output O-l 90 7h F Output loaded to 2.8A. Max. temp.at T1coil=91.7 C, T=65.2K; T1core=92.1 C, T=65.6K ; lug near L=43.3 C, T=16.8K; Input wire=48.6 C, T=22.1K ; CB near D2=68.5 C, T=42K CB near MOV =52.9 C, T=84.5K; CB near IC1=111 C, T=67.7K ; CY1 body=83.7c, T=57.2K; IC2 body=71.2 C, T=44.7K ; CB near D8=96.8 C, T=70.3K; Output wire=65 C, T=38.5K; Internal enclosure near T1=65 C, T=38.5K; Outer enclosure near T1=56.4 C, T=29.9K ; Ambient=26.5 C No hazard, No damaged. For output model: EFS OO

47 - age 47 of 48 - Output O-l 264 6h F Output loaded to 2.1A. Max. temp.at T1coil=103.9 C, T=76.4K; T1core=101.7 C, T=74.2K ; lug near L=44.3 C, T=16.8K; Input wire=48 C, T=20.5KC ; CB near D2=58.5 C, T=31K CB near MOV =51.5 C, T=24K; CB near IC1=107.8 C, T=80.3K ; CY1 body=87c, T=59.5K; IC2 body=71.9 C, T=44.4K ; CB near D8=106 C, T=78.5K; Output wire=64.5 C, T=37K; Internal enclosure near T1=70.6 C, T=43.1K; Outer enclosure near T1=59 C, T=31.5K ; Ambient=27.5 C No hazard, No damaged. For output model: EFS OO Output O-l 264 7h F Output loaded to 1.6A. Max. temp.at T1coil=99.1 C, T=72.4K; T1core=96.7 C, T=70K ; lug near L=47.4 C, T=20.7K; Input wire=52.6 C, T=25.9K ; CB near D2=59.9 C, T=33.2K CB near MOV =54.7 C, T=28K; CB near IC1=104.4 C, T=77.7K ; CY1 body=85.7c, T=59K; IC2 body=70.8 C, T=44.1K ; CB near D8=100.1 C, T=73.4K; Output wire=59.2 C, T=32.5K; Internal enclosure near T1=68.8 C, T=42.1K; Outer enclosure near T1=57.8 C, T=31.1K ; Ambient=26.7 C No hazard, No damaged. For output model: EFS OO

48 - age 48 of 48 - Output O-l 264 6h F Output loaded to 1.31A. Max. temp.at T1coil=99.1 C, T=72.4K; T1core=96.7 C, T=70K ; lug near L=47.4 C, T=20.7K; Input wire=52.6 C, T=25.9K ; CB near D2=59.9 C, T=33.2K CB near MOV =54.7 C, T=28K; CB near IC1=104.4 C, T=77.7K ; CY1 body=85.7c, T=59K; IC2 body=70.8 C, T=44.1K ; CB near D8=100.1 C, T=73.4K; Output wire=59.2 C, T=32.5K; Internal enclosure near T1=68.8 C, T=42.1K; Outer enclosure near T1=57.8 C, T=31.1K ; Ambient=26.7 C No hazard, No damaged. For output model: EFS OO Output O-l 264 6h F1 0.2 Output loaded to 1.0A. Max. temp.at T1coil=86.6 C, T=59.9K; T1core=83.3 C, T=56.6K ; lug near L=42.8 C, T=16.1K; Input wire=42.1 C, T=15.4K ; CB near D2=51.2 C, T=24.5K CB near MOV =45.5 C, T=18.8K; CB near IC1=88.4 C, T=61.7K ; CY1 body=73.9c, T=47.2K; IC2 body=60.7 C, T=34K ; CB near D8=89.2 C, T=62.6K; Output wire=48.5 C, T=21.8K; Internal enclosure near T1=56.9 C, T=30.2K; Outer enclosure near T1=46.3 C, T=19.6K ; Ambient=26.7 C No hazard, No damaged. For output model: EFS OO

49 - age 49 of 48 - Output O-l 264 6h F Output loaded to 0.9A. Max. temp.at T1coil=94.7 C, T=68K; T1core=85.8 C, T=59.1K ; lug near L=37.5 C, T=10.8K; Input wire=41.7 C, T=15K ; CB near D2=52.2 C, T=25.5K CB near MOV =45.2 C, T=18.6K; CB near IC1=94.4 C, T=67.7K ; CY1 body=73.2c, T=46.5K; IC2 body=62.2 C, T=35.5K ; CB near D8=81.9 C, T=55.2K; Output wire=49.7 C, T=23K; Internal enclosure near T1=62.3 C, T=35.6K; Outer enclosure near T1=50.1 C, T=23.4 C ; Ambient=26.7 C No hazard, No damaged. supplementary information: S-c = short circuit, O-l = overload, O-c = open circuit *) Fuse current is more than fuse rating times 2.1.

50 - age 50 of TABLE: list of critical components and materials Component Enclosure lug Holder (fixed plug for UL, EU, K, J, CN, TW, IN, ID, MY, VN, TL) lug Holder (interchangeabl e plug for CE (Europe, United Kingdom, Australia plug), GS (Europe plug), UK (United Kingdom plug), AU, EM, KR, AR, TH, US, WW, AI) Manufacturer/ trademark Sabic Innovative lastics China Co., Ltd. Sabic Innovative lastics China Co., Ltd. Sabic Innovative lastics China Co., Ltd. Type/model Value / rating Standard Approval/ Reference 940(f1) V-0 min., 1.5 UL94 UL (E45329) mm thick min., 120ºC min. 940(f1) V-0 min., 1.5 UL94 UL (E45329) mm thick min., 120ºC min. SE1X(GG)(f1) V-1 min., 1.5 mm thick min., 105ºC min. UL94 UL (E207780) CB Various Various V-0 min., 130 C UL 94, UL 796 UL rimary lead Various Various VW-1, 300V, UL758 UL wire 24AWG, 80 min Fuse (F1) XC Electronics (Shenzhen) 3T T2AH, 250Vac IEC , IEC VDE ( ) X-Capacitor (CX1) (Optional) Alt.) Alt.) Bleeder Resistors (R1, R2) Bridging Diode (D1-D4) Ripple capacitor (C1) HUSAN TAI ELECTRONICS CO., LTD Dain Electronic Co., Ltd. Tenta MCY MX MEX Max. 0.1μF, Min. 250Vac 100 C (X2 min.) Various Various 510kΩ, 1/4W (two in series, located after fuse) Various Various Min. 1A, min. 600Vac Various Various Max. 33μF, Min. 400V, Min. 105 C IEC ed., incl. 21 days damp heat test, UL1414 IEC60065 IEC IEC VDE, UL (125205) VDE, UL (094607) VDE, UL (119119) Tested in the equip. Tested in the equip. Tested in the equip.

51 - age 51 of 48 - Component Varistor (MOV) (Optional) *) Line Choke (L1) (Optional) Bobbin rotective IC (IC1) Bridge-Caps. (CY1) (Optional) Alt.) Alt.) Optocoupler (IC2) Manufacturer/ trademark Thinking Eastern Frontier Sumitomo Infineon Technologies HAOHUA Success Hsuan Tai BRIGHT LED ELECTRONICS COR Type/model Value / rating Standard Approval/ Reference TVR10D471 IEC TVR14D471 UL 1449 EFT M9630, M9820 ICE3B0565 CT7 SE CY BC-817C 270Vac min. SD type 3, (located after fuse and not connected between pri. and E) 130 C phenolic, V-0, 150 C Min. 12W, Min. 650V Max.2200pF, Min. 250Vac, 100 C, Y1 type See appendix, Opto Electronic Devices IEC60065 UL94 IEC IEC ed., UL1414 IEC , UL 1577 VDE( ) UL(E314979) Tested in the equip. UL(E41429) UL(E41429) Tested in the equip. VDE, UL ( ) VDE, UL (118218) VDE, UL ( ) VDE, UL ( ) Alt.) Cosmos Electronics Corp KC817X FIMKO, UL (201103) Alt.) Transformer (T1, For output 5V to 6V.) 1) Bobbin Triple insul. wire Transformer (T1, For output 7V to 8.9V.) 1) Bobbin Triple insul. wire Everlight Eastern Frontier Sumitomo Furukawa Eastern Frontier Sumitomo Furukawa EL817 EFT M9630 or M9820 TEX-E EFT M9630 or M9820 TEX-E Class B henolic, V-0, 130 C Class B henolic, V-0, 130 C IEC60065 Clause 14.3 UL 94 IEC/EN ) IEC60065 Clause 14.3 UL 94 IEC/EN ) VDE, UL (132249) Tested in the equip. UL VDE Tested in the equip. UL(E41429) VDE(006735)

52 - age 52 of 48 - Component Transformer (T1, For output 9V to 12V.) 1) Bobbin Triple insul. wire Transformer (T1, For output 14V to 16V.) 1) Bobbin Triple insul. wire Transformer (T1, For output 18V to 20.9V.) 1) Bobbin Triple insul. wire Transformer (T1, For output 21V to 24V.) 1) Bobbin Manufacturer/ trademark Eastern Frontier Sumitomo Furukawa Eastern Frontier Sumitomo Furukawa Eastern Frontier Sumitomo Furukawa Eastern Frontier Sumitomo M9630 or M9820 TEX-E henolic, V-0, 130 C Type/model Value / rating Standard Approval/ Reference EFT Class B IEC60065 Tested in the Clause 14.3 equip. EFT M9630 or M9820 TEX-E EFT M9630 or M9820 TEX-E EFT M9630 or M9820 TEX-E Class B henolic, V-0, 130 C Class B henolic, V-0, 130 C Class B henolic, V-0, UL 94 IEC/EN ) IEC60065 Clause 14.3 UL 94 IEC/EN ) IEC60065 Clause 14.3 UL 94 IEC/EN ) IEC60065 Clause 14.3 UL 94 UL(E41429) VDE(006735) Tested in the equip. UL(E41429) VDE(006735) Tested in the equip. UL(E41429) VDE(006735) Tested in the equip. UL(E41429) Triple insul. wire Furukawa 130 C IEC/EN VDE(006735) 2) Mylar sheet Toray E60L V-2, 105 C UL94 UL(E86511) 1 ) an asterisk indicates a mark which assures the agreed level of surveillance supplementary information: 1) For bobbin and others material of transformers, refer to transformer specification. 2) No difference between IEC Annex U and IEC Annex H. The above transformer are source same except N3(pin 9-10) of wiring turn refer to construction of transformer. *) Varistor complies with UL 1449 which cover the required 15 combination pulses 6kV (1.2/50μs)/ 3kA (8/20μs) test this is more strict than table I group 1 of IEC

53 - age 53 of 48 - ZB ANNEX ZB TO EN , SECIAL NATIONAL CONDITIONS DK: certain types of Class I apparatus, see , may be provided with a plug not establishing earthing continuity when inserted in Danish socket-outlets NO: In Norway, due to IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230V in case of a single earth fault DK: mains cord for single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to Heavy Current Regulations Section D1 DK: Class I equipment with socket-outlets with earthing contact, or which are intended to be used in locations where protection against indirect contact is required shall be provided with a plug in compliance with Standard Sheet DK 2-1a DK: socket-outlets for providing power to Class II equipment with a rated current of 2,5 A shall have dimensions according to the drawing on page 179 of EN :2002 other dimensions shall be to IEC Standard Sheet C 1a for portable socket-outlets DK: mains socket-outlets with earthing contact shall comply with Heavy Current Regulations Section D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a GB: equipment fitted with a flexible cable or cord provided with a 13A BS 1363 plug as in Statutory Instrument 1768:94 IE: equipment fitted with a flexible cable or cord provided with a 13 A plug in accordance with Statutory Instrument 525:97 Class II apparatus. Considered. The apparatus provided with direct plug. Class II apparatus. No socket-outlet. Class II apparatus. The apparatus must be evaluated before marketed in United Kingdom. The apparatus must be evaluated before marketed in United Kingdom. NO: mains socket-outlets on Class II equipment meet CEE ublication 7 with the following amendments: - dimensions 2,5 A, 250 V socket-outlets shall comply with Standard Sheet I page 180 of EN : mechanical strength 2,5 A, 250 V socketoutlets tested as specified in EN , No socket-outlet. No socket-outlet. - protecting rim also tested No socket-outlet.

54 - age 54 of 48 - NO: method b) of 8.1 is not permitted. Double or reinforced insulation is required between parts connected to the mains and parts connected to the public telecommunications network J.2 NO: In Norway, due to IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230V in case of a single earth fault. No TNV circuit. Considered. ZC ANNEX ZC TO EN , A-DEVIATIONS 5 DE: additional markings required in German language: - cathode ray tubes with an accelerating voltage between 20 kv and 30 kv (marking on the tube) - TV receivers whose picture tube has an accelerating voltage between 20 kv and 30 kv - TV receivers whose picture tube has an accelerating voltage greater than 30 kv - TV receivers whose picture tube has an accelerating voltage less than 20 kv 5.1 IT: additional markings on the outside of the TV receiver in Italian language IT: user instructions in Italian language including a conformity declaration IT: certification number on the back cover 14 SE: Switches containing mercury such as thermostats, relays and level controllers are not allowed. No CRT in the equipment. No switches containing mercury.

55 - age 1 of 9 - Tables to IEC/EN th edition Touch current expressed as voltages U1 and U2 in Annex D Location Fuse in Mains pole Live accessible terminal Mains pole Neutral accessible terminal Measured U1 V (peak) Measured U1 V (DC) Measured U2 V (peak) ass ass Mains pole Live enclosure ass Mains pole Neutral enclosure ass supplementary information No other part exceeds 35V peak or 60V dc Limits : U1 Max 35V (peak) U1 Max 1.0V (DC) U2 Max 0.35V (peak)

56 - age 2 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

57 - age 3 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

58 - age 4 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

59 - age 5 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

60 - age 6 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

61 - age 7 of 9 - Tables to IEC/EN th edition 13.2 Table: working voltage measurement Location eak voltage (V) RMS voltage (V) Comments For model: EFS OO T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin T1 pin 1 to pin T1 pin 2 to pin T1 pin 3 to pin T1 pin 5 to pin IC2 pin 1 to IC2 pin 1 to IC2 pin 2 to IC2 pin 2 to CY1 pri. to sec T1 pin 5 to C IC2 pin 2 to T IC2 pin 3 to C supplementary information Vin=240V 60Hz

62 - age 8 of 9 - Tables to IEC/EN th edition TABLE: clearance and creepage distance measurements clearance cl and creepage distance dcr at/of: Basic: Live to Neutral (before fuse) (on CB) Up (V) U r.m.s. (V) required cl (mm) cl (mm) required dcr (mm) dcr (mm) Basic: Fuse In to out (on CB) Basic: rimary trace after fuse to Live pin on plug (on Component) >>3.4 1 ) Reinforced: CY1 pri. to sec Reinforced: T1 primary to secondary (on CB) Reinforced: T1 pin 3 to R7 (on CB) Reinforced: IC2 pri. to sec. (on CB) Reinforced: rimary component to external chassis supplementary information: See appended table for internal distances of transformer(s) 1 ) with >1 mm gap 2 ) linear interpolation ) ) >>6.7 1 ) There is heat shrinkable tubes on fuse. There is one layer of insulator under CB soldering side to plug pin for non-interchangeable plug adaptor. The following component is tested with 2N force:fuse F1, D1, C1, C5, R3, IC3, CY1, primary and secondary wires. Glues are added on Fuse F1, MOV, D3, C1 and CY1.

63 - age 9 of 9 - Tables to IEC/EN th edition Transformer/motor, constructional requirements Loc. Tested insulation Working voltage Insulati on Res. Required electric strength Required distance peak / V rms / V M Ohms kv (60 s) clearan ce / mm creepage distance / mm T1 rimary core secondary * distance thr. insul. T1 rimary secondary * Loc. Tested insulation Measur ed Insulati on Res. Tested electric strength Measured distance M Ohms kv (60 s) clearan ce / mm creepage distance / mm distance thr. insul. T1 rimary core secondary TIW T1 rimary secondary TIW supplementary information: * 2 or 3 layers / 0.4mm / Annex U TABLE: Opto Electronic Devices Manufacturer BRIGHT LED ELECTRONICS COR Cosmos Electronics Corp Type External creepage Distance Internal creepage Through insulation Bridging insulation BC-817C Reinforced KC817X Reinforced Everlight EL Reinforced supplementary information 17.1 Torque test to Table 20: Screw Diameter With Without Material Torque test (Nm) Location / function (mm) Head Head Screw Nut Fulfilled / Remarks supplementary information

64 - age 1 of 1 - Layout of WB Copy of CB, layout of tracing (not to scale):

65 - age 1 of 1 - Construction of transformer Construction / winding diagram / component part no: T1 Manufacturer: Eastern Frontier Model: EFT-00172, EFT-00186, EFT-00187, EFT-00188, EFT-00189, EFT-00190

66 - age 1 of 12 - hotos Fixed plug with China plug Fixed plug with China plug

67 - age 2 of 12 - hotos Fixed plug

68 - age 3 of 12 - hotos

69 - age 4 of 12 - hotos Mylar sheet (only for fixed plug) Removable plug with US

70 - age 5 of 12 - hotos Removable plug with US Removable plug with US

71 - age 6 of 12 - hotos Removable plug with US Removable plug with Europe

72 - age 7 of 12 - hotos Removable plug with Europe Removable plug with Thailand

73 - age 8 of 12 - hotos Removable plug with Thailand Removable plug with UK

74 - age 9 of 12 - hotos Removable plug with UK Removable plug with Australia

75 - age 10 of 12 - hotos Removable plug with Australia

76 - age 11 of 12 - hotos

77 - age 12 of 12 - hotos The metal which delivers mains fixed in enclosure by plastic with ultrasonic welding which can not be remove and not affecting to connection with plug part. The plug part fixed on enclosure of adapter by direct slot down and locks automatically

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of www.nemko.com TEST REORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Reference o.... : 125414 Date of issue... :

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf Of. Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf Of. Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor ALICATION FOR LOW VOLTAGE DIRECTIVE On Behalf Of Company Limited Liability «Faraday Electronics» Switching Mode ower Adaptor Model: 19W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) repared For : Company

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Audio, video and similar electronic apparatus Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus Safety requirements Test Report issued under the responsibility of: TEST REORT IEC 60065 Audio, video and similar electronic apparatus Safety requirements Report Number.... : 180301943SHA-001 Date of issue... : 2018-03-30

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

Audio/video, information and communication technology equipment Part 1: Safety requirements

Audio/video, information and communication technology equipment Part 1: Safety requirements Test Report issued under the responsibility of: TEST REORT Audio/video, information and communication technology equipment art 1: Safety requirements Report Number... : 151101256SHA-001 Date of issue...

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools art 2: articular requirements for drills and impact drills Report reference No.... : 3130837.50A

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG age 1 of 38 Report No.ETS-060067 TEST REORT IEC 60601-1 / EN 60601-1 Medical electrical equipment art 1: General requirements for safety Report reference No.... : ETS-060067 Testled by (+ signature)...

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

Household appliances. Terje Ulsrud. 12 June 2018

Household appliances. Terje Ulsrud. 12 June 2018 Household appliances Terje Ulsrud 12 June 2018 1 International news IEC 60335-1 Edition 6 Planned to be published 2019 2 Internet connection 3 Internet connection The current 60335-1 does not adequately

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ File E132594 Project 02ME17432 2003-02-09 REPORT on CORD CONNECTED CLASS 2 POWER UNITS Globtek Inc. Northvale, NJ Copyright 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes

More information

Audio/video, information and communication technology equipment Part 1: Safety requirements

Audio/video, information and communication technology equipment Part 1: Safety requirements age 1 of 50 TEST REORT Audio/video, information and communication technology equipment art 1: Safety requirements Report Number... : 68.210.18.0025.01 Date of issue... : 2018-03-19 Total number of pages...

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

Part 1: General requirements for basic safety and essential performance

Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REORT art 1: General requirements for basic safety and essential performance Report Number.... : 130501061SHA-001 Date of issue... : 2013-07-01 Total

More information

Page 1 of 4 Report Reference No. CPSZ IEC /EN Clause Requirement + Test Result Remark Verdict

Page 1 of 4 Report Reference No. CPSZ IEC /EN Clause Requirement + Test Result Remark Verdict age 1 of 4 Report Reference No. CSZ0928781 Report Reference No... : Tested by (name and signature)... : Approved by (name and signature).. : TEST REORT IEC 61010-1/ EN 61010-1 Safety requirements for electrical

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND Reference No.: WTF16F0961094C age 2 of 5 Test Results: Test Item(s) Unit Test Result No.1 MDL Maximum Allowable Limit Lead (b) % ND 0.0002 See comment if > 0.004 % Cadmium (Cd) % ND 0.0002 0.002 Mercury

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information