onlinecomponents.com Definite Purpose, Lighting and Heating Controls

Size: px
Start display at page:

Download "onlinecomponents.com Definite Purpose, Lighting and Heating Controls"

Transcription

1 Definite Purpose, Lighting and Heating Controls 5 Definite Purpose Contactors 5/ Class 4, 45 Nomenclature 5/ Class 4, 45 Applications 5/ Class 4, 45 Part Numbers 5/4 Class 4, 45 Modifications & Accessories Definite Purpose Starters 5/5 Class 6 Product Nomenclature 5/6 Class 6 General Applications 5/7 Class 6 Part Numbers 5/8 Class 6 Modifications & Accessories Replacement Parts for Definite Purpose Controls 5/9 Class 6, 4 Replacement Parts Lighting and Heating Controls 5/ Class LE Electrically Held Lighting Contactors 5/4 Class CLM Mechanically Held Contactors Manual Control 5/7 Class SM ractional HP Starters 5/9 Class MMS, MRS Switches 5/ Class MMS, MRS, SM Modifications Kits 5/ Class SM Heater Elements Siemens ICP 0

2 Definite Purpose Control Definite Purpose Contactors Class 4 & 45 product nomenclature Class 45 D.P. CONTACTOR Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager. 45 C G 0 A J A CLASS AMP RATING MODEL POWER POLES NC POWER POLES ENCLOSURE COIL MODIICATIONS 45 Contactor C 0 G power pole 0 None A Open D 00-08V, 60 HZ A Jumper Bar (D.P.) D 5 power poles power pole E V, 60 HZ E 0 power poles 550V, 50 HZ * Class B coil 5 0V, 60 HZ standard. G 40 0V, 50 HZ Binding head G 08-40V, 60 HZ screws and quad 90-0V, 50 HZ quick connect H V, 60 HZ standard V, 50 HZ J 4V, 60 HZ * Suffix 600R to 4V, 50 HZ 999R denotes L 77V, 60 HZ special modifi- 40V, 50 HZ cations. Class 4 D.P. CONTACTOR * Contact cover and * Other voltages taped coil comes available. Please standard. contact sales office. Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager. 4 B 5 A J P B CLASS AMP MODEL POWER CONTROL ENCLOSURE COIL POWER INTERLOCKS RATING POLES CIRCUIT TERMINALS 4 Contactor A 5 power poles 5 Without A Open A 0-0/ K No screws w/qc s A SPDT left (D.P.) B 0 E* 4 power poles auxiliary B NEMA 0-40V, 60 HZ L Binding head screws B NO left C 40 power poles contact C Open w/din C 0-40/ M Sems screws C NO & NC left D 50 * NO & NC rail mtg V, 60 HZ N Lugs D NO & NC both E 60 amp power poles base 0V, 50 HZ P Binding head screws left & right 75 only 7 NO & NC 0V, 60 HZ w/qc s E SPDT right G 90 power poles G 90-0V, 50 HZ Q Sems screws w/qc s NO & NC left H 0 8 NO & NC 08-40V, 60 HZ R Lugs w/qc s SPDT left I 50 power poles J 4V, 50 HZ S Binding head screws SPDT right 4V, 60 HZ & aux. screws G NO left & H V, 50 Hz T Sems screws & aux. NO right V, 60 HZ screws H NC left & E 550V, 50 Hz V Lugs w/aux. screws NC right V, 60 HZ W Binding head screws K SPDT left L 40V, 50 HZ all locations. DQC L SPDT right 77V, 60 HZ on line side only. M NC right D 00-08V, 60 HZ Y Sems screws all N NO right K 00-0V, 50 HZ locations. DQC on O NC left 00-0V, 60 HZ line side only. P NO left OEM Use Only Z Lugs all locations NC right coil w/terms. Up DQC on the line side R NC left G coil w/terms. Up only. NO right J coil w/terms. Up S SPDT left 4 H coil w/terms. Up OMIT = P type SPDT right 5 E coil w/terms. Up terminals on A & B 6 L coil w/terms. Up rated contactors, or Whenever an inlk is 7 D coil w/terms. Up R type terminals specified, a power on C, D, E,, & G term. must also be * Other voltages rated contactors. specified in the available. Please contact sales office. preceding field. * A special three letter customer suffix will be assigned by the Product Manager for additional modifications. 5/ Siemens ICP 0

3 Class 45 Definite Purpose Control Definite Purpose Contactors Class 4 & 45 product general application Benefits Power Termination Options Compact Size One Pole Version Includes Shunt Bar Interchangeable Mounting Durable Metal Back Plate Standard Class B Coil Insulation Class 4 Benefits Compact Size 45CG0AJA Interchangeable Mounting Durable Metal Back Plate Power Terminations Options Reinforced Thermalset Polyester Housing Quiet Operation 4A5A 4D5A 45CG0A Quiet Operation Weld-resistant Silver Cadmium Oxide Contacts Power Terminal Operations 45EG0AJA Reinforced Thermalset Polyester Housing Contact Covers and Taped Coils Come Standard 4E5A06 Weld-resistant Silver Oxide Contacts Optional Din Rail Mounting Snap-on Electrical/Mechanical Interlocks Visual Contact Position Indication Low VA Coils Standard for 5A 40A 45EG0A 4H5A Common Definite Purpose Applications Air Conditioning Heating Ventilating Refrigeration ood and Beverage Industry Conveyors Elevators Lighting Pool and Spa Welding Pump and Compressor 5 6 or further products and dimensions see Definite Purpose Controls Catalogue 5.0_04/04_A&D-07 7 Siemens ICP 0 5/

4 Definite Purpose Control Definite Purpose Contactors Class 4 & 45 part numbers Ordering Information Use complete catalog number. Replace the (*) with letter from the coil table or additional information see Definite Purpose Controls Catalogue 5.0_04/04_A&D-07 Coil Table 60Hz 50Hz Voltage Letter 4 4 J D G L H E Class 45 0V 40V 77V 480V 600V Non Inductive LA Hp LRA Hp LRA Hp LRA Hp LRA Hp Amps Poles Catalog No CG0A*A DG0A*A EG0A*A G0A*A GG0A*A CG0A* DG0A* EG0A* G0A* GG0A* 96. * To order without jumper bar, remove the A from the end of the part number. Class LA 60Hz 600V AC Max 0V 40V 77V 480V 600V Non Inductive LA Hp LRA Hp LRA Hp LRA Hp LRA Hp Amps Poles Catalog No A5A* A5A* A5A* B5A* B5A* B5A* C5A* C5A* C5A* D5A* D5A* E5A* E5A* E5A* E5A* GE5A* GE5A* H5A* H5A* I5A* I5A* 56. 5/ Siemens ICP 0

5 Definite Purpose Control Definite Purpose Contactors Modifications and accessories ield Modification Kits Description Class Contactor LA Auxiliary Contacts Catalog Number NO 49ACR0 NC 49ACRC NO & NC 49ACR NO 49ACR7 NC 49ACR8 Snap-on Side Mounted SPDT 49D Auxiliary Contacts SPDT 49D NO 49D NC 49D500 SPDT 49CE4SPDT NO 49D5468N0 NC 49D5468NC Mechanical Interlock D DIN Rail Kit D & 4-pole 49D Enclosure Only EA4BEB EA4GEB No replacement parts are available for the Class 45 contactors. One per side is all you can add in the field of the Snap-on Side Mounted Auxiliary Contacts through 90 amp. actory Assembled Modifications Description Class Contactor LA Coil Suffix Letter Lugs (each terminal) L Clamp Screw (each terminal) L Siemens ICP 0 5/4

6 Definite Purpose Control Definite Purpose Starters Class 6 product nomenclature Class 6 D.P. STARTER Information shown on nomenclature sheets is for reference only to identify devices from existing catalog numbers. This information is not to be used for the creation of new catalog numbers by anyone except the Product Marketing Manager. 6 B 5 A J 4 CLASS AMP RATING MODEL POWER POLES CONTROL CIRCUIT ENCLOSURE COIL OVERLOAD Optional Suffixes 6 Starter A 5 power poles Auxiliary contact, A Open A 0-0/ 4 -phase comp. * Special three letter B 0 E* 4 power poles left (NO pole for B NEMA 0-40V, 60 HZ bimetal w/nc suffix for factory C 40 power poles -Wire remote C 00-40/ contacts modifications D 50 *75-90 push button) V, 60 HZ 8 Single phase assigned by Product E 60 amp only 5 Without auxiliary 0V, 50 HZ comp. bimetal Marketing Manager. 75 contact 0V, 60 HZ w/nc contacts G 90 Start Stop P.B. G 90-0V, 50 HZ H 0 4 Hand-Off-Auto 08-40V, 60 HZ * This field is left I 50 Selector Switch J 4V, 50 HZ blank for V, 60 HZ amp which are H V, 50 HZ equipped with V, 60 HZ solid state ESP E 550V, 50 HZ 00 overload V, 60 HZ No heaters L 40V, 50 HZ are necessary. 77V, 60 HZ D 00-08V, 60 HZ K 00-0V, 50 HZ 00-0V, 60 HZ 5/5 Siemens ICP 0

7 Class 6 Definite Purpose Control Definite Purpose Starters Class 6 general application Definite Purpose Starter eatures Class 4 Contactor Construction eatures 6E5A Dependable Overload Relays available in both Class 0 and Class 0 Trip Common Mounting Configurations and Dimensions 5 60A Solid State Overloads Standard on 75 90A Dual Voltage Coils Available Contact Sales Office 6H5A8 6A5A4 6C5A4 6D5A Siemens ICP 0 5/6

8 Definite Purpose Control Definite Purpose Starters Class 6 part numbers Ordering Instructions Use complete catalog number Replace the (*) with letter from coil table Heater tables can be found in the Definite Purpose Controls Catalogue 5.0_04/04_A&D-07 Locked Rotor Amps Normally Open LA 40V 480V 600V Poles Auxiliary Contact Catalog Number Definite Purpose Starters, 5-40 LA 60 Hz 600VAC Max (Open Type Starters with Bimetal Overloads) 6A5A*8 6AA* A5A*4 6AA*4 4 6A5A*4 6B5A*8 6BA* B5A*4 6BA*4 4 6B5A*4 6C5A*8 6CA* C5A*4 6CA*4 4 6C5A*4 Definite Purpose Starters, LA 60 Hz 600VAC Max (Open Type Starters with Bimetal Overloads) 6D5A* DA*8 6D5A*4 6DA*4 6E5A* EA*8 6E5A*4 Coil Voltages Table 60 Hz 50 Hz Letter 4 4 J D G L H E 0-0/ A / C EA*4 Definite Purpose Starters, LA 60 Hz 600VAC Max (Open Type Starters ESP00 Overloads) E5A* 6EA* GE5A* 6GEA* Definite Purpose Starters, 0-50 LA 60 Hz 600VAC Max (Open Type Starters) H5A*8 6HA* I5A*8 6IA*8 5/7 Siemens ICP 0

9 Definite Purpose Control Definite Purpose Starters Class 6 modifications and accessories ield Modification Kits Description Class Contactor LA Auxiliary Contacts Catalog Number Snap-on Side Mounted Auxiliary Contacts Enclosure Only To order a starter in a NEMA enclosure, change the 7th character of the catalog number to a B. EXAMPLE: 6C5A in a NEMA enclosure is 6C5B. NO 49ACR0 NC 49ACRC NO & NC 49ACR NO 49ACR7 NC 49ACR8 SPDT 49D SPDT 49D NO 49D500 NC 49D500 SPDT 49CE4SPDT NO 49D5468N0 NC 49D5468NC EA6CEB EA6EEB One per side is all you can add in the field of the Snap-on Side Mounted Auxiliary Contacts through 90 amp. Contact Sales Office or Pricing Siemens ICP 0 5/8

10 Definite Purpose Control Definite Purpose Contactors Class 6 & 4 replacement parts AC Coils Class 6, 4 Third ourth Character Character Catalog Insert of Cat. No. of Cat. No. Volts 60 Hz Volts 50 Hz Number D54760J D D54760D 75D54760 N B D54760G D54760L D54760H D54760E Class 6, 4, 4, 44 Third ourth Character Character Catalog Insert of Cat. No. of Cat. No. Volts 60 Hz Volts 50 Hz Number D70646J D D70646D 75D70646J A, B, C, D, E D70646G D70646L D70646H D70646E D D D5477J D D5477D 75D5477, G E D5477G D5477L D5477H D5477E D75J D75 0-0/0-40 0/ D75A D75D 75D75 H, I D75G D75L 0-40/ / D75C D75H D75E Replacement coils are standard VA coils with screw terminals. Replacement coils with quick connects are available for 5-60 amp contactors. Contact Sales Office for part number. 5/9 Siemens ICP 0

11 Contact Kits (Contains Complete Pole) Class 6, 4 Third Character ourth Character of Cat. No. of Cat. No. Catalog Number A 75A4 B 75B4 C 75C4 D 75D4 E 75E4 E 75E4 G E 75GE4 H I Overload Relays Ambient Compensated Bimetal Class 6 75H4 75I4 Third Character ourth Character Number of Cat. No. of Cat. No. of Poles Catalog Number A, B C D, E H I Solid State ESP 00 Class 6 48DH8A6 48DH8A6 48EH8A6 48EH8A6 48GH8AA6 48GH8A6 48HC8AA 48IC8AA6 Third Character ourth Character Number of Cat. No. of Cat. No. of Poles Catalog Number G 48DSPM LA Class 0 48DSKM LA Class 0 E E Definite Purpose Control,, Definite Purpose Contactors Class 6 & 4 replacement parts 48DSPM0 48DSKM Siemens ICP 0 5/0

12 Lighting and Heating Control Electrically Held Lighting Contactors General eatures Compact Design Silver Cadmium Oxide Contacts Pressure Type Terminals Straight Thru Wiring Wide Variety of Contact Configurations Poles Maximum Available rom 0 Amps 400 Amps Up to Poles 0, 0 and 60 Amps Poles On Amps ull Line of Enclosures NEMA NEMA R/ NEMA 4/4X (Stainless Steel) Available In Combination orm with Choice of: usible Disconnect Non-usible Disconnect Circuit Breaker All combination lighting contactors are UL service entrance listed. ull Line of actory And ield Modifications UL Listed iles #E4900 CSA Certified ile LR 655 Application Siemens electrically held lighting contactors provide a safe, convenient means of local or remote switching for tungsten and ballast lamp loads, mercury arc lamps, and phase resistive heating. These lighting contactors are rated at 480V Tungsten, 600V Ballast. They are available in poles with a variety of NO and NC contact arrangements. 5/ Siemens ICP 0

13 Open and Non-combination Enclosed Contactors Ordering Information Lighting and Heating Control Electrically Held Lighting Contactors, Class LE Replace the *** with a number from the coil table. Technical data see ield modification kits see page /4. actory modification kits see page /49. Coil Table 60Hz Voltage Open Type NEMA NEMA NEMA 4/4X Stainless Steel General Purpose NEMA /R Watertight, Dusttight, Industrial Use Corrosion Resistant, Max. Number Normally Normally Weatherproof 04 Stainless Steel Amp of Closed Open Rating Poles Contacts Contacts Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 0 LEN00B00***A 7. LEN0B00***A 40. LEN0B00***A 7. LEN04B00***A LEN00B00***A 7. LEN0B00***A 40. LEN0B00***A 7. LEN04B00***A LEN00B00***A 40. LEN0B00***A 6. LEN0B00***A 94. LEN04B00***A LEN00B00***A 40. LEN0B00***A 6. LEN0B00***A 94. LEN04B00***A LEN00B400***A 09. LEN0B400***A. LEN0B400***A 46. LEN04B400***A LEN00B0***A 09. LEN0B0***A. LEN0B0***A 46. LEN04B0***A 65. LEN00B0***A 09. LEN0B0***A. LEN0B0***A 46. LEN04B0***A LEN00B004***A 09. LEN0B004***A. LEN0B004***A 46. LEN04B004***A LEN00B04***A 40. LEN0B04***A 479. LEN0B04***A 556. LEN04B04***A LEN00B006***A 40. LEN0B006***A 479. LEN0B006***A 556. LEN04B006***A LEN00B404***A 548. LEN0B404***A 65. LEN0B404***A 70. LEN04B404***A LEN00B06***A 548. LEN0B06***A 65. LEN0B06***A 70. LEN04B06***A LEN00B008***A 548. LEN0B008***A 65. LEN0B008***A 70. LEN04B008***A LEN00B405***A 594. LEN0B405***A 67. LEN0B405***A 764. LEN04B405***A LEN00B07***A 594. LEN0B07***A 67. LEN0B07***A 764. LEN04B07***A LEN00B009***A 594. LEN0B009***A 67. LEN0B009***A 764. LEN04B009***A LEN00B406***A 640. LEN0B406***A 77. LEN0B406***A 84. LEN04B406***A LEN00B08***A 640. LEN0B08***A 77. LEN0B08***A 84. LEN04B08***A LEN00B00***A 640. LEN0B00***A 77. LEN0B00***A 84. LEN04B00***A LEN00B408***A 7. LEN0B408***A 8. LEN0B408***A 96. LEN04B408***A LEN00B0***A 7. LEN0B0***A 8. LEN0B0***A 96. LEN04B0***A LEN00B0***A 7. LEN0B0***A 8. LEN0B0***A 96. LEN04B0***A LEN00C00***A 6. LEN0C00***A 78. LEN0C00***A 44. LEN04C00***A LEN00C006***A 540. LEN0C006***A 556. LEN0C006***A 70. LEN04C006***A LEN00C009***A 89. LEN0C009***A 84. LEN0C009***A 004. LEN04C009***A LEN00C0***A 096. LEN0C0***A. LEN0C0***A 8. LEN04C0***A LEN00D00***A 479. LEN0D00***A 556. LEN0D00***A 77. LEN04D00***A LEN00D006***A 04. LEN0D006***A. LEN0D006***A 47. LEN04D006***A LEN00D009***A 590. LEN0D009***A 667. LEN0D009***A 064. LEN04D009***A LEN00D0***A 45. LEN0D0***A. LEN0D0***A 690. LEN04D0***A LEN00E00***A 77. LEN0E00***A 96. LEN0E00***A 7. LEN04E00***A LEN0000***A 85. LEN000***A 76. LEN000***A 89. LEN0400***A LEN00G00***A 405. LEN0G00***A 469. LEN0G00***A LEN04G00***A LEN00H00***A 6. LEN0H00***A 744. LEN0H00***A 579. LEN04H00***A Selection Number or conduit hubs and conversion instructions, see page 8/87. Can be field assembled. Order mounting kit 49MCMPMA and required number of contactors. Example,, three pole contactors and mounting plate for a 9 pole open assembly. 6 7 Siemens ICP 0 5/

14 Lighting and Heating Control Combination Electrically Held Lighting Contactors, Class LE Selection Ordering Information Replace the *** with a number from the coil table. Technical data see ield modification kits see page /4. actory modification kits see page /49. Coil Table 60Hz Voltage Number Combination Lighting Contactors NEMA NEMA, NEMA /R NEMA 4/4X Stainless Steel General Purpose NEMA 4 Painted (thru 00 amps) Watertight, Dusttight, Industrial Use Corrosion Resistant Max. Number Disc Disc Amp/ Circuit Weatherproof, Watertight, Dusttight 04 Stainless Steel Disconnect Amp of NO Amp use Clip Breaker Type Rating Poles Rating Rating Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ 0 0A LEDBB00***A 465. LEDBB00***A 58. LEDB4B00***A A LEDBC00***A 475. LEDBC00***A 700. LEDB4C00***A 977. Non-usible 60 60A LEDDD00***A 747. LEDDD00***A 94. LEDD4D00***A A LEDE00***A 774. LEDE00***A 0. LED4E00***A A LEDH00***A 465. LEDH00***A 474. LEDH400***A A LEDKG00***A 77. LEDKG00***A LEDK4G00***A A/50V LEAB00***A 48. LEAB00***A 54. LEA4B00***A 96. 0A/600V LEBB00***A 49. LEBB00***A 544. LEB4B00***A A/50V LEAC00***A 49. LEAC00***A 66. LEA4C00***A 99. 0A/600V LEBC00***A 50. LEBC00***A 66. LEB4C00***A 00. usible 60 60A/50V LECD00***A 767. LECD00***A 945. LEC4D00***A A/600V LEDD00***A 784. LEDD00***A 96. LED4D00***A A/50V LEEE00***A 849. LEEE00***A 77. LEE4E00***A A/600V LEE00***A 886. LEE00***A. LE4E00***A A/50V LEG00***A 59. LEG00***A 450. LEG400***A A/600V LEH00***A 6. LEH00***A 45. LEH400***A A/50V LEJG00***A 748. LEJG00***A LEJ4G00***A A/600V LEKG00***A 754. LEKG00***A LEK4G00***A A LEBTB00***A 65. LEBTB00***A 706. LEBT4B00***A 088. Circuit 0 0A LEBVC00***A 66. LEBVC00***A 788. LEBV4C00***A 64. Breaker 60 60A LEBYD00***A 99. LEBYD00***A 07. LEBY4D00***A A LEBZE00***A 96. LEBZE00***A 4. LEBZ4E00***A 88. or conduit hubs and conversion instructions, see page 8/87. 5/ Siemens ICP 0

15 CLM 0 Amp Mechanically Latched Lighting and Heating Contactor The CLM Lighting Contactors can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. They provide reliable and convenient lighting control in numerous applications, such as industrial plants, schools, hospitals, office buildings, shopping centers, airports, stadiums... literally everywhere lighting is required. The CLMs are listed under UL 508 with no derating when used open or enclosed. Combination lighting contactors are listed for UL service entrance. UL listed ile #E4900 CSA Certified ile LR 655 Maximum AC/DC Voltage and Amp Ratings Poles to Load Load Amperes for Phase Type Continuous for Phase for Phase Tungsten 0 50V AC 50V AC Ballast 0 47V AC 600V AC General 0 47V AC 600V AC General 0 5V DC 50V DC Inrush Current Over use Size (amps RMS) at AC Control Voltage Amps 0V 40V 77V 47V 480V Inrush use Type CLM 0 Amp Lighting Contactor Solid State Control Modules The CLM 0 amp lighting contactor is an electromagnetically operated, mechanically latched three wire control contactor. The most commonly used method of control is a three position momentary contact switch with a center-off position. The controlling device must be able to make the coil inrush current but need not break it. The coil current is interrupted by the control contacts within the CLM contactor. Power for the control line may come from a separate source or directly from the line side of the CLM contactor. The CLM contactor can also be controlled by devices such as: Operation through control modules. Lighting and Heating Control Mechanically and Magnetically Held Lighting Contactors Break-glass control stations Timers having single-pole, double throw contacts Photo-electric cells Energy management systems Microprocessors CLM 00 Amp Occupancy sensors The functions of our Solid State Control Modules for the 0 amp CLM are as follows: Control modules make it possible to use a controlling device that does not have enough current-carrying capacity to control the CLM contactor directly. Control modules are also used when the control station is to be located at a distance greater than the allowable contactor line run. Another use for control modules occurs when the controlling device is only available as a single-pole single-throw contact necessitating a two wire control line. Still another application for control modules is when start-stop three wire control is needed. Control modules also can make it possible to operate the CLM coil from its own incoming line at one voltage while providing the control at a second, perhaps lower voltage. Two Wire Control Module (Accessory 47) The advantages of two wire controls are:. Control station can have lower ampacity rating.. Control station can be located an extended distance from the CLM contactor.. Control module can frequently be controlled directly from microprocessor. 4. Control devices can be two wire single-pole, single-throw types. 5. Control voltage may be different than the CLM coil circuit and at a lower voltage level. Selection Note: If the control power to the solid state control module is lost while the module is energized the lighting contactor will open. If the line power to the lighting contactor is lost while the contactor is energized the contactor will not change state with return of line voltage. Power will be restored to the load if the control module is still energized. Control station should be the maintained type. Three Wire Control Module (Accessory 48) The advantages of three wire control are:. The accessory 48 consists of two relays with contacts appropriately interconnected which provides for an interlocking that prevents both relays from being energized simultaneously.. This module has similar characteristics to the two wire module (Accessory 47) except there is no change of switch contact position upon loss of control line power. Control stations should be the momentary type. Stop-Start Control Module (Accessory 49) Stop-start three wire maintained control is an arrangement used mostly when controlling motors, but can be used in lighting applications. Any number of momentary contact control stations consisting of normally open start buttons and normally closed stop buttons can be used. Start buttons are connected in parallel and stop buttons in series. Operation (Magnetic Latch) A permanent magnet is built into the contactor structure of the 0A, 60A, 00A, and 00A contactors that will maintain the contactor in its energized state indefinitely without using control power. When energized, a DC current is applied that produces a magnetic field that reinforces the polarity of the permanent magnet, and the contactor pulls in immediately. The current to the coil is disconnected by the coil clearing interlock. In order to drop out the contactor, it is necessary to apply a field through the O coil in the reverse direction to the permanent magnet. This momentarily cancels the magnetic attraction and the contactor drops out. Coil and module failures are possible when used with solid state relays and PLC outputs. 4-volt systems are ok to use, but 0 volts and above should be discouraged. If higher values cannot be avoided, an interposing relay should be used Siemens ICP 0 5/4

16 Lighting and Heating Control Mechanically and Magnetically Held Lighting Contactors, Class CLM Selection Ordering Information Replace *** with a number from the coil table. Technical data see ield modification kits see page /4. actory modifications see page /49. Coil Table 60Hz Voltage Number Open and Non-combination Enclosed Contactors Open Type Enclosure NEMA NEMA NEMA 4/4X Stainless Steel General Purpose NEMA /R Watertight, Dusttight, Industrial Use Corrosion Resistant, Max Weatherproof 04 Stainless Steel Amp Number Rating of Poles Catalog Number Catalog Number Catalog Number Catalog Number CLMB0*** CLMB0*** CLMSB0** * CLMB0*** CLMB0*** CLMSB0** * 4 CLMB04*** CLMB04*** CLMSB04** * 0 6 see table see table CLMB06*** CLMB06*** CLMSB06** * 8 below below CLMB08*** CLMB08*** CLMSB08** * 0 CLMB0*** CLMB0*** CLMSB0** * CLMB*** CLMB*** CLMSB** * CLM0C0*** CLMC0*** CLMC0*** CLMSC0** * 0 CLM0C0*** CLMC0*** CLMC0*** CLMSC0** * 4 CLM0C04*** CLMC04*** CLMC04*** CLMSC04** * 5 CLM0C05*** CLMC05*** CLMC05*** CLMSC05** * 6 CLM0C06*** CLMC06*** CLMC06*** Now 8 CLM0C08*** CLMC08*** CLMC08*** Available! 9 CLM0C09*** CLMC09*** CLMC09*** 0 CLM0C0*** CLMC0*** CLMC0*** CLM0C*** CLMC*** CLMC*** CLM0D0*** CLMD0*** CLMD0*** CLMSD0** * 60 CLM0D0*** CLMD0*** CLMD0*** CLMSD0** * 4 CLM0D04*** CLMD04*** CLMD04*** CLMSD04** * 5 CLM0D05*** CLMD05*** CLMD05*** CLMSD05** * 6 CLM0D06*** CLMD06*** CLMD06*** Now 8 CLM0D08*** CLMD08*** CLMD08*** Available! 9 CLM0D09*** CLMD09*** CLMD09*** 0 CLM0D0*** CLMD0*** CLMD0*** CLM0D*** CLMD*** CLMD*** CLM0E0*** CLME0*** CLME0*** CLMSE0** * 00 CLM0E0*** CLME0*** CLME0*** CLMSE0** * 4 CLM0E04*** CLME04*** CLME04*** CLMSE04** * 5 CLM0E05*** CLME05*** CLME05*** CLMSE05** * CLM00*** CLM0*** CLM0*** CLMS0** * 00 CLM00*** CLM0*** CLM0*** CLMS0** * 4 CLM004*** CLM04*** CLM04*** CLMS04** * 5 CLM005*** CLM05*** CLM05*** CLMS05** * 00 CLM0G0*** CLMG0*** CLMG0*** CLM0G0*** CLMG0*** CLMG0*** 400 CLM0H0*** CLMH0*** CLMH0*** CLM0H0*** CLMH0*** CLMH0*** Open 0 Amp Contactors Max 0 0V Coil 50/60Hz 08 40V Coil 50/60Hz 65 77V Coil 50/60Hz V Coil 50/60Hz Amp Number Rating of Poles Catalog Number Catalog Number Catalog Number Catalog Number CLM0 CLM0 4 CLM CLM60 8 CLM80 0 CLM00 CLM0 Contactors with 6 poles will be assembled with all poles located in the top portion of the contactor. Contactors with 8 poles will be assembled with 6 poles in the top portion and the remaining poles in the bottom portion of the contactor. CLM06 CLM07 CLM06 CLM07 CLM406 CLM407 CLM606 CLM607 CLM806 CLM807 CLM006 CLM007 CLM06 CLM07 4 volt coils are not available on 0, 00 and 400 amp contactor sizes. or 4 volt control of 0 amp contactor select solid state control module. or conduit hubs and conversion instructions, see page 8/87. = NOW AVAILABLE CLM09 CLM09 CLM409 CLM609 CLM809 CLM009 CLM09 0A mechanically held lighting contactors require a solid-state control module. CLM 0 & 60A 6- pole can be field assembled. Order mounting kit 49MCMPMA and the appropriate number of contactors. 5/5 Siemens ICP 0

17 Lighting Control Combination Mechanically and Magnetically Held Lighting Contactors, Class CLM Combination Lighting Contactors Ordering Information Replace *** with a number from the coil table. Technical data see ield modification kits see page /4. actory modifications see page /49. Coil Table Enclosure NEMA NEMA, NEMA /R NEMA 4/4X Stainless Steel General Purpose NEMA 4 Painted (thru 00 amps) Watertight, Dusttight, Industrial Use Corrosion Resistant, Contactor Number Disc Disc Amp Circuit Weatherproof, Watertight, Dusttight 04 Stainless Steel Disconnect Amp of NO Amp use Clip Breaker Type Rating Poles Rating Rating Rating Catalog Number Catalog Number List Price $ Catalog Number List Price $ 0 0A CMNB4*** CMNB4*** CMNBS4** * 0 0A CMNC4*** CMNC4*** CMNCS4** * Non-usible 60 60A CMND5*** CMND5*** CMNDS5** * 00 00A CMNE6*** CMNE6*** CMNES6** * 00 00A CMN7*** CMN7*** CMNS7** * A CMNG8*** CMNG8*** CMNGS8** * 0 0A/50V CMB0*** CMB0*** CMBS0** * 0A/600V CMB*** CMB*** CMBS** * 0 0A/50V CMC0*** CMC0*** CMCS0** * 0A/600V CMC*** CMC*** CMCS** * usible 60 60A/50V CMD*** CMD*** CMDS** * 60A/600V CMD*** CMD*** CMDS** * 00 00A/50V CME4*** CME4*** CMES4** * 00A/600V CME5*** CME5*** CMES5** * 00 00A/50V CM6*** CM6*** CMS6** * 00A/600V CM7*** CM7*** CMS7** * A/50V CMG8*** CMG8*** CMGS8** * 400A/600V CMG9*** CMG9*** CMGS9** * 0 0A CMBB4*** CMBB4*** CMBBS4** * Circuit 0 0A CMBC5*** CMBC5*** CMBCS5** * Breaker 60 60A CMBD8*** CMBD8*** CMBDS8** * 00 00A CMBE8*** CMBE8*** CMBES8** * 00 00A CMB0*** CMB0*** CMBS0** * 00 00A CMBG*** CMBG*** CMBGS** * Selection 60Hz Voltage Number A mechanically held lighting contactors require a solid-state control module. 4 volt coils are not available on 0 and 00 amp contactors. Use solid state control module on 0 amp size. or conduit hubs and conversion instructions, see page 8/ Siemens ICP 0 5/6

18 Manual Control ractional HP Starters, Class SM General Class SM Class SM fractional horsepower starters provide overload protection as well as manual on-off control for small horsepower motors in a variety of industrial and commercial applications. Available in one or two pole versions, these devices are suitable for use with AC single phase motors up to HP. Two pole starters can also be used with DC motors up to 4 HP. Typical applications include fans, conveyors, pumps, and small machine tools. Continuous Current Rating 6 amperes. Overload Trip Assembly Motor protection is provided by a Class SMH heater element which must be installed before the starter will operate. Two Speed Starters Two speed manual starters are designed for control of small single phase AC motors having separate windings for high and low speed operation. Two toggle operated starters are used, with overload protection included for each motor winding. Surface mounting devices, and those with a gray flush plate, utilize a mechanical interlock which allows direct control of the motor by means of the toggle operators. Enclosures Class SM, NEMA Type surface mounting enclosures are sheet steel with a thermo-plastic wrap-around cover for convenience in wiring. The NEMA Type enclosure is also available in an oversized version which allows more wiring space. A zinc alloy die casting is used for NEMA Type 4 enclosures. Pilot Lights Red or green neon pilot light units are available for flush mounting plates, NEMA Type enclosures, and NEMA Type 4 enclosures. Pilot lights may be either factory or field installed. (or starters that contain a pilot light, a Red light is standard. or a Green pilot light add "G" to the end of the catalog number.) Terminals Binding head screw type terminals are suitable for #0 or smaller copper wire, and are accessible from the front. All terminals are clearly marked. Mounting Open types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout. Single-unit flush mounting types, including those with pilot lights, are suitable for wall mounting in a standard switch box or for machine cavity mounting without a box. Operation Available with toggle handle or with removable key type operator to discourage unauthorized operation. Class SM Starter in a NEMA Type Enclosure with Pilot Light Emergency Off Actuator A toggle operator extender is available for Class SM, NEMA Type surface mounted units. The extender has a red vinyl button that provides a fast and easy method for locating and switching the device s toggle operator into the O position. The Emergency Off Actuator is available in kit form only for field installation. Handle Guard/Lock-Off An optional handle guard on Class SM, NEMA Type enclosed starters prevents accidental operation of the toggle operator and also allows the toggle operator to be padlocked in either the ON or O position. This handle guard can be factory installed on NEMA Type enclosed starters and is also available in kit form for field installation on NEMA Type surface and flush mounting enclosures. Standard NEMA Type 4 metallic enclosures include provisions for padlocking the device in the O position. 5/7 Siemens ICP 0

19 Class SM Starter in a NEMA Type Enclosure with Pilot Light Ordering Information Heater Elements see page 5/. Technical Data see ield Modification Kits see page 5/. Maximum Horsepower AC Single Phase DC Volts Pole Pole Pole StarterClass SM, Single Phase General Purpose lush Mounting NEMA Type General Purpose NEMA Type NEMA NEMA Open Starter with lush Plate Enclosure, Surface Mounting R, 4 & Type 4 Type 7 & 9 (No Enclosure Provided) Watertight, Watertight, Class I Groups Standard Jumbo Dust-tight Dust-tight B, C, D & Metallic Metallic Class II Groups Gray Stainless Stainless Enclosure Enclosure E,, G lush Steel Steel with Clear Cover Enclosures Type Open Type Plate lush Plate lush Plate Standard Oversized of No. of Catalog Catalog Catalog Catalog Catalog Catalog Catalog Catalog Catalog Operator Poles Starter eatures Number Number Number Number Number Number Number Number Number Standard SM0 SM SMS SMG SMGJ SMWN Red Pilot Light SM0P SMP SMSP SMSJP SMGP SMGJP SMWNP Toggle Standard SM0 SM SMS SMG SMGJ SMWN Red Pilot Light SM0P SMP SMSP SMSJP SMGP SMGJP SMWNP Standard SM0 SM SMS SMG SMGJ SMWN Red Pilot Light SM0P SMP SMSP SMSJP SMGP SMGJP SMWNP Key Standard SM04 SM4 SMS4 SMG4 SMGJ4 SMWN4 Red Pilot Light SM04P SM4P SMS4P SMSJ4P SMG4P SMGJ4P SMWN4P One Starter in Duplex EnclosureClass SM, Single Phase General Purpose lush Mounting Open Starter with lush Plate - (No Enclosure Provided) Horsepower Ratings Gray lush Plate Stainless Steel lush NEMA Type General or Wall or Cavity Plate for Wall or Cavity Purpose Enclosure Replacement Type of Number Mounting Mounting Surface Mounting Starters Operator of Poles Starter eatures Catalog Number Catalog Number Catalog Number Catalog Number Toggle Standard SMG0 Red Pilot Light SMG0P Key Red Pilot Light SMG04P Two Starters In Duplex EnclosureClass SM, Single Phase Standard SM SMG Toggle Per Starter Red Pilot Light on Each Starter SMP SMSP SMGP Key Per Starter Red Pilot Light on Each Starter SM44P SMS44P SMG44P Starter And Auto-Off-Hand SPDT Selector Switch (AC Only)Class SM, Single Phase Standard SM7 SMG7 Red Pilot Light SM7P SMS7P SMG7P Toggle Standard SM7 SMG7 Red Pilot Light SM7P SMS7P SMG7P Key Red Pilot Light SM74P SMS74P SMG74P Two Speed Starters (AC Only)Class SM, Single Phase Mechanical Interlock SM SMG SM0T Mechanical Interlock and () Red Pilot Lights SMP SMGP SM0PT Toggle Mechanical Interlock, HIGH-O-LOW SMS0P SM0PT Selector Switch and () Red Pilot Lights Mechanical Interlock SM SMG SM0T Mechanical Interlock and () Red Pilot Lights SMP SMGP SM0PT Mechanical Interlock, HIGH-O-LOW Selector Switch and () Red Pilot Lights SMS0P SM0PT One heater element required. urnished with () 4" NPT Outlet in bottom (reversible for top feed). Two heater elements required. Order Open Type starter plus separate handle guard kit. Manual Control ractional HP Starters, Class SM Selection or starters that contain a pilot light, a Red light is standard. or a Green pilot light add "G" to the end of the catalog number Siemens ICP 0 5/8

20 Manual Control ractional HP Switches, Class MMs, MRS General Class MMS, MRS Class MMS and MRS motor starting switches provide manual ON-O control of single or three phase AC motors where overload protection is not required or is provided separately. Compact construction and a 600 volt rating make these switches suitable for a wide range of industrial and commercial uses. Typical applications include small machine tools, pumps, fans, conveyors and many other types of electrical machinery. They can also be used on non-motor loads such as resistance heating applications. Continuous Current Rating MMS & MRS: 0 amperes at 50 volts max, 6.4 amperes at 77 volts, 0 amperes at 600 volts max, 0 amperes resistive at 600 volts max. Two SpeedClass MRS Two speed manual switches may be used with separate winding three phase or single phase AC motors where overload protection is not required or is provided separately. Two switches are employed to give ON-O control in each speed. ReversingClass MRS Reversing manual switches provide a compact means of starting, stopping and reversing AC motors where overload protection is not required or is provided separately. They are suitable for use with three phase squirrel cage motors and for single phase motors which can be reversed by reconnecting motor leads. Two switches are used, one to connect the motor forward rotation and one for reverse. Enclosures Class MMS, MRS, NEMA Type surface mounting enclosures are sheet steel with a thermo-plastic wrap-around cover for convenience in wiring. The NEMA Type enclosure is also available in an oversized version which allows more wiring space. A zinc alloy die casting is used for NEMA Type 4 enclosures. Pilot Lights Red or green neon pilot light units are available for flush mounting plates, NEMA Type enclosures, and NEMA Type 4 enclosures. Pilot lights may be either factory or field installed. (or switches that contain a pilot light, a Red light is standard. or a Green pilot light add "G" to the end of the catalog number.) Terminals Binding head screw type terminals are suitable for #0 or smaller copper wire, and are accessible from the front. All terminals are clearly marked. Mounting Open types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout. Single-unit flush mounting types, including those with pilot lights, are suitable for wall mounting in a standard switch box or for machine cavity mounting without a box. Operation Available with toggle handle or with removable key type operator to discourage unauthorized operation. Class MMS Switch in a NEMA Type Enclosure Emergency Off Actuator A toggle operator extender is available for Class MMS, MRS, NEMA Type surface mounted units. The extender has a red vinyl button that provides a fast and easy method for locating and switching the device s toggle operator into the O position. The Emergency Off Actuator is available in kit form only for field installation. Handle Guard/Lock-Off An optional handle guard on Class MMS, MRS, NEMA Type enclosed switches prevents accidental operation of the toggle operator and also allows the toggle operator to be padlocked in either the ON or O position. This handle guard is available in kit form for field installation on NEMA Type surface and flush mounting enclosures. Standard NEMA Type 4 metallic enclosures include provisions for padlocking the device in the O position. 5/9 Siemens ICP 0

21 Class MMS Switch in a NEMA Type Enclosure Ordering Information Heater Elements not Required Technical Data see ield Modification Kits see page 8/79. Dimensions see pages 8/98. Wiring Diagrams see page 8/7. SwitchClass MMS, Single Phase and Phase Reversing SwitchClass MRS, Single Phase and Phase Manual switches do not include overloads. urnished with () /4" NPT outlet in bottom (reversible for top feed). In order to obtain a 4" NPT outlet in top and bottom, add suffix letter H to type number and add $5 to List Price. Manual Switches, Control Class MMS, MRS Do not use as replacement interiors for NEMA Type 4 metallic enclosures. or replacement unit, order Type MMSK0 or MMSK0 and separate pilot light kit. Selection General Purpose lush Mounting NEMA Type General Purpose NEMA Type NEMA NEMA Open Switch with lush Plate Enclosure Surface Mounting R, 4 & Type 4 Type 7 & 9 (No Enclosure Provided) Watertight, Watertight, Class I Groups Standard Jumbo Dust-tight Dust-tight B, C & D & Gray Stainless Stainless Metallic Enclosurer Metallic Class II Groups with Clear Cover Enclosure E,, G lush Steel Steel Enclosures Type No Open Type Plate lush Plate lush Plate Standard Oversized of of Switch Catalog Catalog Catalog Catalog Catalog Catalog Catalog Catalog Catalog Operator Poles eatures Number Number Number Number Number Number Number Number Number Standard MMSK0 MMSK MMSKS MMSKG MMSKGJ MMSKWN MMSKW MMSKR Red Pilot Light 5V AC MMSK0A MMSKA MMSKSA MMSKSJA MMSKGA MMSKGJA MMSKWNA MMSKWA Toggle Key General Purpose lush Mounting NEMA Type Open Switch with lush Plate General Purpose Replacement Switch Type of Number of Suitable Switch eatures (Including (No Enclosure Provided) Enclosure Surface Mounting Class MRS Operator Poles Motor Types Mechanical Interlock) Catalog Number List Price $ Catalog Number List Price $ Catalog Number Toggle Single Phase Standard MRSK MRSKG MRSK0T -Lead Red Pilot Device5V AC MRSKA MRSKGA MRSK0AT Repulsion-Induction Red Pilot Device 0V AC MRSKB MRSKGB MRSK0BT Phase: Also Standard MRSK MRSKG MRSK0T Single Phase Capacitor, Red Pilot Light0 0V AC MRSKA MRSKGA MRSK0AT Split Phase, or 4-Lead Red Pilot Light08 0V AC MRSKB MRSKGB MRSK0BT Repulsion-Induction Red Pilot Light V AC MRSKC MRSKGC MRSK0CT Two Speed SwitchClass MMS, Single Phase and Phase General Purpose lush Mounting NEMA Type Open Switch with lush Plate General Purpose Replacement Switch Type of Number of Suitable Switch eatures (Including (No Enclosure Provided) Enclosure Surface Mounting Class MRS Operator Poles Motor Types Mechanical Interlock) Catalog Number List Price $ Catalog Number Catalog Number List Price $ Toggle Red Pilot Light 0V AC MMSK0B MMSKB MMSKSB MMSKSJB MMSKGB MMSKGJB MMSKWNB MMSKWB Standard MMSK0 MMSK MMSKS MMSKG MMSKGJ MMSKWN MMSKW MMSKR Red Pilot Light 08-40V AC MMSK0B MMSKB MMSKSB MMSKSJB MMSKGB MMSKGJB MMSKWNB MMSKWB Red Pilot Light V AC MMSK0C MMSKC MMSKSC MMSKSJC MMSKGC MMSKGJC MMSKWNC MMSKWC Standard MMSK0 MMSK MMSKS MMSKG MMSKGJ MMSKWN Red Pilot Light 5V AC MMSK0A MMSKA MMSKSA MMSKSJA MMSKGA MMSKGJA MMSKWNA Red Pilot Light 0V AC Horsepower Ratings Device Class MMS MMSK0B MMSKB MMSKSB MMSKSJB MMSKGB MMSKGJB MMSKWNB Standard MMSK04 MMSK4 MMSKS4 MMSKG4 MMSKGJ4 MMSKWN4 Red Pilot Light 08 40V AC MMSK04B MMSK4B MMSKS4B MMSKSJ4B MMSKG4B MMSKGJ4B MMSKWN4B Red Pilot Light MMSK04C V AC MMSK4C MMSKS4C MMSKSJ4C MMSKG4C MMSKGJ4C MMSKWN4C Single Phase Standard MMSK MMSKG MRSK0T Two Winding () Red Pilot Devices5V AC MMSKA MMSKGA MRSK0AT (-Lead) () Red Pilot Devices0V AC MMSKB MMSKGB MRSK0BT Phase Standard MMSK MMSKG MRSK0T Separate Winding () Red Pilot Lights08 40V AC MMSKB MMSKGB MRSK0BT (Wye-Connected) () Red Pilot Lights V AC MMSKC MMSKGC MRSK0CT No of Poles Motor Type AC Maximum HP 5V 0V V DC Ratings 90V 5V Single Phase / Phase 7 / 0 / Class MRS Single Phase / Reversing Phase 7 / 0 / Single Phase Class MMS / Phase, Constant or Variable Torque 7 Two Speed / 0 / Phase, Constant Horsepower 7 / 0 / or switches that contain a pilot light, a Red light is standard. or a Green pilot light add "G" to the end of the catalog number. 0V Siemens ICP 0 5/0

22 ield Modification Kits Class SM, MMS, MRS Selection AccessoriesClass SM Description Handle Guard Kit with Padlock Provision Emergency Off Actuator Additional Key for Key Operated Devices Pilot Light KitsClass SM Red Pilot Light Catalog Number SML SMPB SMK Green Pilot Light Device Voltage Rating Catalog Number Catalog Number Class SM 5 77V AC SMPL0 SMPL0G EnclosuresClass SM Catalog Enclosure Type or Use With SM Number Standard Size NEMA General Purpose Oversized NEMA Type General Purpose NEMA R, 4, Watertight Dust-tight O, OP, O, OP, O, OP, O4, O4P O, OP, O, OP, O, OP, O4, O4P O, OP, O, OP, O, OP, O4, O4P SME SME SM40BC NameplatesClass SM Catalog Number Nameplate Without With or Use On Marking Pilot Light Pilot Light Standard commercial switch box cover including None SMN stainless steel plates Stainless Steel Plate None SMSN SMSN4 NEMA None SMN0 SMN40 surface mounted High SMN SMN4 enclosure or gray flush plate Low SMN SMN4 Replacement PartsClass SM, MMS Description Replacement Toggle Kits:Type W and KW (NEMA 4 Metallic Enclosure) AccessoriesClass MMS, MRS Description Handle Guard Kit with Padlock Provision Emergency Off Actuator Additional Key for Key Operated Devices Pilot Light KitsClass MMS, MRS Catalog Number SMHW Catalog Number SML SMPB SMK Red Green Voltage Pilot Light Pilot Light Device Rating Catalog Number Catalog Number 0 0V AC SMPL SMPLG Class MMS 08 77V AC SMPL SMPLG V AC SMPL SMPLG EnclosuresClass MMS Catalog Enclosure Type or Use With MMS Number Standard Size KO, KOP, KOB, KO, NEMA KOA, KOB, KO, KOA, MMSKE General Purpose KOB, KO4, KO4A, KO4B Oversized KO, KOB, KOC, KO, NEMA Type KOA, KOB, KO4, KO4B, MMSKE General Purpose KO4C, KO Jumbo KO, KOB, KOC, KO, NEMA Type KOA, KOB, KO4, KO4B, MMSKE General Purpose KO4C, KO NEMA R, 4, KO, KOB, KOC, KO, Watertight KOA, KOB, KO4, KO4B, SM40BC Dust-tight KO4C NameplatesClass MMS Catalog Number Nameplate Without With or Use On Marking Pilot Light Pilot Light Standard commercial switch box cover including None SMN stainless steel plates NEMA None SMN0 SMN0 surface mounted High SMN SMN enclosure or Low SMN SMN gray flush plate orward SMN Reverse SMN4 SMN4 Pilot lights can be field installed on standard NEMA general purpose surface mount enclosures, and NEMA R, 4 and enclosures only. or flush mounting units a complete switch unit with pilot light must be ordered. 5/ Siemens ICP 0

23 Heater Elements Class SM Heater Catalog Number Motor ull-load Current (Amps) SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH.7.5 SMH.0.9 SMH.8.54 SMH SMH SMH Table A Number of Heater Elements Ordering Information Number of Device Heater Elements Notes SM* SM* All single pole and two pole SM SM* starters require only Heater SM*4 Element. SM*5 SM*6 SM* Duplex Unit. One Heater Element SM*44 per starter. SM* Two Speed Starter. One Heater SM* Element per speed. Heater Catalog Number Motor ull-load Current (Amps) SMH SMH SMH9.6.8 SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH SMH49.. SMH50..9 SMH SMH Table BSpecial Applications Heater Element Selection Continuous Duty Motor Service actor Manual Control Heater Elements, Class SM Ambient Temperature of Motor Constant 0 C Constant 0 C Same as (8 ) Higher (8 ) Lower Controller Than Controller Than Controller Ambient Ambient Ambient ull Load Current Multiplier.5 to General. Determine number of heater elements required from Table A.. Determine motor full load current and service factor. NOTE: If motor amps are unknown, an approximate value may be found on page 8/45. These values should be used with caution and only when motor amps are not available.. If the motor and controller are in the same ambient temperature: a. or.5 to.5 service factor motors use 00% of motor full load current for heater element selection. b. or.0 service factor motors use 90% of motor full load current for heater element selection. 4. If the motor and controller are in different ambient temperatures multiply motor full load current by the multiplier in Table B. Use the resultant full load current for heater element selection. 5. Select proper heater element from table below. 6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40 C (04 ) or less. Always be certain the correct heater element is installed in the starter before operating the motor Siemens ICP 0 5/

24 Manual Control Starters and Switches, Class -RV General Class - RV Class across the line manual starters and switches provide control for machinery where remote start stop control is not required. Class - RV manual starters are used for single and poly-phase motors up to 600V. Starters have bimetallic heater elements to provide class 0 overcurrent protection. Each starter has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation helps prevent the starter from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. A built-in differential trip bar causes the starter to trip faster on a phase loss condition to help reduce motor damage. Magnetic trip elements in each starter take the device off line when it senses current of times the maximum LA dial setting. Class - RV switches provide control for inherently protected motors. Typical applications include metal and woodworking machinery, grinders, power saws, conveyors, fans, pumps, blowers, textile and packaging machinery, and paper cutters. Each switch is provided with magnetic trip elements which take the device off line when it senses current of times the maximum switch rating. Class - RV manual starters can be used as Type E self-protected manual combination starters (up to amps) per UL508 or as components in Group Installation per NEC When using the Class - RV as a manual combination starter upstream protection is not required. Class These manual controllers are available with low voltage protection which will automatically open the power poles when the voltage drops or the power is interrupted. Controllers with the LVP option provide the OSHA requirements for protecting personnel from potential injury caused by the automatic start-up of machinery following a voltage drop or power interruption when low voltage protection is specified. Class - RV is available as Open style, or in NEMA, NEMA 7 & 9 or NEMA 7 & 9 / & 4 enclosures. Standard eatures include: ON/O rotary handle with lockout and visible trip indication Adjustment dial for setting to motor LA (Starters only) Low Voltage Protection (LVP) Option Short Circuit trip at times the maximum setting of the LA dial or rated current Ambient compensated up to 40 Phase loss sensitivity Test trip function LVP Option Meets OSHA Requirements UL Listed CSA Certified OPEN TYPE Starter NEMA General Purpose NEMA 7 & 9 Class I Group C & D Class II Group E, & G NEMA & 4, NEMA 7 & 9 Class I Group C & D Class II Group E, & G 5/ Siemens ICP 0

25 Class Manual Motor Starter Manual StarterClass - RV LA Max HP Enclosure Adjustment Single-Phase Phase Open Type NEMA NEMA 7 & 9 NEMA & 4, NEMA 7 & 9 Range HP Ratings HP Ratings General Purpose Class I Groups C & D Watertight (Outdoor use) Class II Groups E, & G Class I Groups C & D Class II Groups E, & G 5V 0V 00V 0V 460V 575V Catalog Number List Price $ Catalog Number List Price $. Catalog Number List Price $ Catalog Number List Price $ RV0-0AA0 ADB ADH ADW RV0-0BA0 BDB BDH BDW RV0-0CA0 CDB CDH CDW RV0-0DA0 DDB DDH DDW RV0-0EA0 EDB EDH EDW RV0-0A0 DB DH DW RV0-0GA0 GDB GDH GDW / RV0-0HA0 HDB HDH HDW 0.7- / / RV0-0JA0 JDB JDH JDW /4 /4 RV0-0KA0 KDB KDH KDW.-.6 /0 /4 RV0-AA0 LDB LDH LDW.4- /8 / RV0-BA0 MDB MDH MDW.8-.5 /6 / / / / RV0-CA0 NDB NDH NDW.-. /0 /4 /4 /4 / RV0-DA0 PDB PDH PDW.8-4 /8 / /4 RV0-EA0 QDB QDH QDW.5-5 /6 / RV0-A0 RDB RDH RDW /4 /4 / / 5 5 RV0-GA0 SDB SDH SDW / 5 5 RV0-HA0 TDB TDH TDW 7-0 / / 7 / 0 RV0-JA0 UDB UDH UDW 9-.5 / 7 / 0 RV0-KA0 VDB VDH VDW RV0-4AA0 WDB WDH WDW 4-0 / 5 7 / 5 0 RV0-4BA0 XDB XDH XDW 7-7 / 7 / 5 0 RV0-4CA0 YDB YDH YDW / 7 / 5 0 RV0-4DA0 ZDB ZDH ZDW Manual SwitchClass - RV Instantaneous Magnetic Trip will occur at times the maximum LA dial setting or rated switch current. Discount Code: SIRIUS R Contactors, OL's, MSP's Shaded Ratings apply for Manual Motor Controllers Only! These Ratings do not apply as UL Listed Manual Combination Starters. Ordering Information No heaters required. Technical Data see ield modification kits see page 5/5. Dimensions see page 5/6. Wiring Diagrams see page 5/7. or applications requiring a low voltage protection coil see table at right. Manual Control Starters and Switches, Class -RV Low Voltage Protection Coil Table 60 Hz Voltage Letter 0V * 08V * D 40V * G 460V * H *Add corresponding letter to end of base Class catalog number for low voltage protection coil. $85 list adder. Note: The LVP option for Open type RV is available from the factory, please order separately from the field modification kits on page 5/5. The coil voltage should correspond with the line voltage. Rated Max HP Enclosure Current Single-Phase Phase Open Type NEMA NEMA 7 & 9 NEMA & 4, NEMA 7 & 9 HP Ratings HP Ratings General Purpose Class I Groups C & D Watertight Class II Groups E, & G Class I Groups C & D Class II Groups E, & G 5V 0V 00V 0V 460V 575V Catalog Number List Price $. Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ / / RV-0JC0 DB DH DW 5 /6 / RV-C0 DB DH DW 0 / / 7 / 0 RV-JC0 DB DH DW 0 / 5 7 / 5 0 RV-4BC0 4DB 4DH 4DW / 7 / 5 0 RV-4DC0 5DB 5DH 5DW Selection Siemens ICP 0 5/4

26 ield Modification Kits Class -RV Selection RV90-D RV90-A RV9-CP0 RV90-DP0 RV98-H Description Auxiliary Contact Blocks Type Catalog Number Plug in contact block SPDT contact, NO/NC RV90-D block per RV NO NC RV90-E mountable at the front SPDT contact NO/NC electronic contact RV90-G Side mount auxiliary NO NC RV90-A contact with NO RV90-B screw connection NC RV90-C Side mount auxiliary NO NC RV90-J contact per RV mountable on the left-hand side Signaling Contact Block Signaling Contact Signaling Contact per RV NO + NC for any trip mountable on the left-hand + side. Can also be fitted NO + NC for short RV9-M together with side mount circuit trip only. auxiliary contact. Auxiliary Releases Undervoltage release AC 50Hz AC 60Hz undervoltage release 0V RV90-A0 per RV mountable on the 0V 08V RV90-AM right-hand side. 45V 40V RV90-AP0 Cannot be fitted together 480V RV90-AV with shunt trip. Undervoltage release AC 50Hz AC 60Hz with early make contacts (NO) 0V 40V RV9-CP0 undervoltage release 45V 480V RV9-CV per RV mountable at the right-hand side. Cannot be fitted together with shunt trip. Shunt trip AC 50Hz/60Hz DC shunt trip per RV 0 4V 0 70V RV90-DB0 mountable at the right- 90 0V 70 90V RV90-D0 hand side. Cannot be 00 40V 90 0V RV90-DP0 fitted together with 50 45V 0 500V RV90-DV0 undervoltage release. Pilot Lights AC 50Hz/60Hz 4V 49SBLBJ or NEMA enclosure only. Kit 0V 49SBLB includes Red, Green, and 40V 49SBLBG Amber lenses 480V 49SBLBH 600V 49SBLBE Lug Kit Required for Type E Manual or RV with amp range: Combination Starter 0.-A up to 480V Max A up to RV98-H 575V Max Mounting Push-in Mounting Hole Kit our mounting holes required for each RV. or screw panel mounting (Kit includes 0 holes) of the RV RB900-0B Sealing device Adjustment Dial covers or sealing the LA adjustment dial (Kit includes 0 covers) RV908-0P List Price $ ront mount auxiliary cover Door Operators or sealing the front mount auxiliary opening. (Kit includes 0 covers) RV90-0H RV90-0H Thru-the-door operators, 0 mm depth RV96-0B Rotary operating mechanism, rated NEMA, lockable with up to padlocks in the O position. With Black Handle Includes extension shift and 0 mm depth with connecting element for the RV. supporting bracket RV96-0K 00% on time 5 sec. max. on time Discount Code: NEMA CONTROL Discount Code: Overload Relays Compatible for use in dusty atmospheres. Contacts rated for -60V. 5/5 Siemens ICP 0

27 RV0 Manual Control Class -RV Dimensions Class - NEMA Enclosure / - /4 NPT /4 - NPT / NPT / - /4 NPT / - /4 NPT / - /4 NPT Class - NEMA 7 & 9, & 4, and NEMA 7 & 9 Enclosure /4 NPT /8 Mounting Screw / - /4 NPT /4 Mounting Screw Typ. () Places / - /4 NPT /4 NPT / - /4 NPT /4 - NPT Siemens ICP 0 5/6

Definite Purpose, Lighting and Heating Controls

Definite Purpose, Lighting and Heating Controls Definite Purpose, Lighting and Heating Controls 5 Definite Purpose Contactors 5/ Class 4, 45 Nomenclature 5/ Class 4, 45 Applications 5/ Class 4, 45 Part Numbers 5/4 Class 4, 45 Modifications & Accessories

More information

Lighting and Heating Control Electrically Held Lighting Contactors

Lighting and Heating Control Electrically Held Lighting Contactors Lighting and Heating Control Electrically Held Lighting Contactors Features Application Compact Design Silver Cadmium Oxide Contacts Pressure Type Terminals Straight Thru Wiring Wide Variety of Contact

More information

Lighting and Heating Control

Lighting and Heating Control Electrically Held Lighting Contactors, Class LE Simplicity and compact lightweight design makes Class LE lighting contactors an attractive solution to your budgeting challenges. Features Used in applications

More information

Control Products NEMA & General Purpose Controls

Control Products NEMA & General Purpose Controls Control Products s Product Overview Class SMF Fractional Horsepower Manual Page 6-5 Class MMS & MRS Fractional Horsepower Manual Switches Page 6-7 Class Manual and Switches Page 6-9 Class 4 NEMA Page 6-4

More information

SPEEDFAX TM 2011 Control Products Contents

SPEEDFAX TM 2011 Control Products Contents SPEEDFAX TM 2011 Control Products Contents What s New 17-3 Product Overview 17-4 Manual Control Fractional HP Starters, Class SMF 17-5 17-6 Switches, Class MMS and MRS 17-7 17-8 Starters and Switches,

More information

Manual Starters and Switches Integral Horsepower Types M and T

Manual Starters and Switches Integral Horsepower Types M and T CLASS 510, 511, 51 INTEGRAL HORSEPOWER STARTERS TYPES M AND T Application Data Types M and T integral horsepower manual starters provide convenient On-Off operation of small single phase, polyphase, or

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Installation Sheet January, 2016 Supersedes February, 2013

Installation Sheet January, 2016 Supersedes February, 2013 s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

Manual Starters and Switches

Manual Starters and Switches Selection Guide Catalog 510CT9701R01/16 016 Class 510, 511, 51, 601 CONTENTS Fractional Horsepower Manual StartersType F............... Page Manual SwitchesType K................................. Page

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

Installation Sheet January, 2016 Supersedes June 2013

Installation Sheet January, 2016 Supersedes June 2013 s Installation Sheet January, 016 Supersedes June 01 E87010-A0105-T00-A6-CLM0 Lighting and Heating Contactor 60, 100, 00 Amp,, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Manual Starters and Switches Selection Guide

Manual Starters and Switches Selection Guide Selection Guide Class 510, 511, 51, 601 CONTENTS Description.....................................................Page Class 510, 51 Type F Fractional Horsepower Manual Starters............... Class 510,

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

Construction Controls Quick Selection Guide

Construction Controls Quick Selection Guide Construction Controls Quick Selection Guide 30,000 products covering commercial projects Siemens NEMA starters, lighting contactors and pilot devices are known for their dependability and ruggedness, and

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 40A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview.............................................. 2 Application Description..........................................

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information

XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1 pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Cross reference. Definite Purpose Contactors

Cross reference. Definite Purpose Contactors Cross reference Definite Purpose Contactors HOMER Tyco/PU Siemens/Furnas GE Culterhammer Schneider/Square D. Honeywell XMC0 100 42/45 CR45 C25 8910 R82 XMCK 100 45 CR45 C25 8910 R82 Contactors HOMER Schneider/TE

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY EDSC210 -Way Switch Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Features Box Type Contact Configuration Current Rating Voltage Rating Material, Color, and

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. &, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. II, Div., Groups F, G NEMA, 7B*CD, 9EFG Applications:

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

Enclosed Molded Case Circuit Breakers

Enclosed Molded Case Circuit Breakers Enclosed Motor Controllers and Molded Case Circuit Breakers KTA7 Type-E Self Protected Manual Motor Controllers Page 89 Explosion-Proof Motor Controllers KTA7_EX Page 9 The following pages contain a selection

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

MOTOR TERMINAL CONNECTIONS

MOTOR TERMINAL CONNECTIONS MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910 s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning,

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes) AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Electrical Motor Controls (Fourth Edition)

Electrical Motor Controls (Fourth Edition) Electrical Motor Controls (Fourth Edition) 1. Which drawing type shows physical details as seen by the eye? Pictorial Drawing 2. Which drawing is similar to a pictorial drawing but has circles or rectangles

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1 MERCURY TO METAL CONTACTORS AND RELAYS GLASS SEAL GUIDE RETAINER TEFLON GUIDE MAGNETIC SLEEVE BOBBIN TERMINAL WELD RING CERAMIC INSULATOR ELECTRODE METAL CAP DESCRIPTION MERCURY TO METAL CONTACTOR: The

More information

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

NEMA Full Voltage Power Devices. Section 1.  Control Catalog 1-1 NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION DBR 30, 60, 100 and 150 Amp Series Receptacles Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

Basics of Control Components

Basics of Control Components Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information