1 s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning, refrigeration, data processing, and food service equipment. New compact and -Pole contactors are available along with standard size,, and -Pole devices. They feature quic connect terminals and binder head screws for easy wiring. Box lugs are standard on 0 ampere contactors and larger. An exclusive DIN trac mounting option may reduce installation costs. Coils can be changed on the DPA contactors quicly without a tool. Auxiliary contact modules snap on either side of the DPA contactors. Compact -Pole Contactors Vac Maximum Loced Rotor 77 V 60 V 7 V Resistive V 0 V DPt $ DPt DPt j DPt.00 Compact -Pole Contactors Vac Maximumc DPV0 -Pole DPV0 -Pole Loced Rotor 77 V 60 V 7 V Resistive,, and -Pole Contactors Vac Maximumc V 0 V j 0 A Res. limited to 77 V. All others rated 0 A Res. (above 77 V). c Above 0 volts, all lines must be switched. t code must be specified to order this product. Refer to standard voltage codes listed below DPt $ DPt DPt DPt 6.00 Loced Rotor 0 V 60 V 7 V Resistance V 0 V 0 V Ø 60/7 V Ø DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPAt DPA6t DPA6t DPA7t DPA7t DPA9t DPA9t DPAt DPAt $ SYD8t SYD0t SYD68t 6.00 Coil Codes DPAV0 -Pole 60 Hz 0 Hz Code DP, DPA V V0 V0 V06 V07f q V 0 Hz only. p Available on s DPA, DPA, and SYD8 only. Not available for DP through DP single-pole devices. f Not available for DP one- and two-pole devices. Code DPA, DPA, SYD Vq V0p V0 V08 V0 V0 V06 V07 For additional information, reference Catalog # 89CT90R6/97 or D-FAX # 7. /00 CP Discount Schedule 000 Square D -8 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (60) ! Outside Local Area: (0) 8-900!
2 s DP, DPA, and SYD Application Data Class 89 Normally Open & Normally Closed -Pole Contactors Vac Maximum Resistive N.C. Class 89 c Form 0 DPAp Y9 $.00 DPAp Y DPAp Y DPAp Y9.00 p code must be specified to order this product. Refer to standard voltage codes listed below. c Above 0 volts, all lines must be switched. NOTE: N.C. poles on outside. N.C. poles open before poles close. Auxiliary Contacts For Use With Class 89 DPA DPA DPA SYD NEMA General Purpose Enclosures for DP and DPA Contactors Application Data Contact Arrangement N.C. & N.C. N.C. & N.C. Class 9999 D D0 D D0 SX6 SX7 SX8 $ Class 89 Class 999 DP 0-0 & DPG $. DPA 0-0 & DPG. DPA & DPG.0 DPA 60-7 & DPG 6.00 DPA 90- & DPG 7.00 DPA & DPG DPA 0 & DPG Mechanical Life: Electrical Life: DP DPA, SYD Duty Cycle: Approvals: UL Component Recognized UL Listed (Form U) CSA Certified DPA is CE mared Coil Replacement 00,000 operations 0,000 operations 00,000 operations Continuous File E0, CCN NLDX File E0, CCN NLDX File LR90, Class Class 89 DPA Replacement Coils Class 9998 Volt u Inrush Sealed f 0-0 A & DAt 6 6 $ A DAt A & DAt A & DAt 9.00 t Replace asteris with suffix from DPA Coil Table, shown below. Example: Coil for Class 89 DPAV0 volt 60 Hz would be a Class 9998 DAV0. u For s DP thru DP: Inrush 0 VA; Sealed VA. f CP Discount Schedule, not CP. See page -8 for SYD Replacement Coils. DPA Coil Table Terminals, 60 Hz q Available for DPA contactors only. 0-0 A 0 A 0-60 A 7-90 A A A 0 A A j Solid or stranded copper wire only. Miscellaneous Parts, 0 Hz Code V V0 V0 V06q V07q Power Terminals of Lug Wire Sizesj Minimum-Maximum Binder Head #-#8 #-#6 #-# #-#I/O #-#I/O #8-0 MCM #8-0 MCM #-00 MCM Description Class 9999 DIN mounting bracet attachment (DPA 0 A to 60 A only) DMB $ 7.0 DP Series B Cover DPC.00 Factory Modifications Auxiliary contacts can be factory installed along with a DIN mounting bracet option. Special terminations are also available. Modification Form Factory installed auxiliary contacts Pressure wire connectors (0-0 amp) Y $.60 per pole Box lugs (0-0 amp) Y $.0 per pole DIN mounting bracet attached ( mm style)c Y $.0 for DP $8.0 for DPA Contact cover for DP Series B Y8 $.00 Contact your nearest Square D/Schneider Electric sales office. c Available for 0 through 60 amp only. Contactor Bottom Tabs Top Hoos No tools required See page - for replacement contacts. Operating Tab Auxiliary Contact Installation For additional information, reference Catalog # 89CT90R6/97 or D-FAX # Square D CP fcp Discount Schedule /00 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (60) ! Outside Local Area: (0) 8-900!
3 s DP, DPA and SYD Approximate Dimensions Class () # or M DP -Pole 0 thru 0 Amps () # or M DP -Pole 0 thru 0 Amps () # or M () # or M DPA and -Pole 0 thru 0 Amps DPA -Pole 0 thru 0 Amps () # or M DPA and -Pole 0 and 60 Amps # or M DPA and -Pole 7 and 90 Amps.7.9 For additional information, reference Catalog # 89CT90R6/97 or D-FAX # 7. / Square D -8 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (60) ! Outside Local Area: (0) 8-900!
4 s DP, DPA and SYD Approximate Dimensions Class Provision for /" DPA Provision for /6" SYD T T T Provision for /" SYD Provision for /" SYD8 For additional information, reference Catalog # 89CT90R6/97 or D-FAX # Square D -8 /00 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (60) ! Outside Local Area: (0) 8-900!
5 Definite Purpose Starters s DPS and H through M Class 89 DPSOV0 No. of Compact -Pole Single -Pole Single -Pole Poly DPSGV0 V 7 / Class 89 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. Definite purpose starters offer: Low Cost Small Size Melting Alloy Overload Bloc Bi-metallic Overload Available - and -Pole Starters Vac Maximum Trip Free Reset Mechanism Open or Enclosed 00,000 Mechanical Operations Loced Rotor Open NEMA Enclosed No. of 0 V 0 V 60/7 V Thermal Ø Ø 0 V 60 V 7 V f q f q Unitsq 7 / 7 / 7 / / DSOt DSOt DSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSOt DPSO6t DPSO7t DPSO9t $ DSGt DSGt DSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSGt DPSG6t DPSG7t DPSG9t $ q s do not include thermal units. Standard trip thermal units are priced at $9.0 each. See page -9 for selection information. f Holding circuit contacts are not provided as standard; refer to table below for it. t code must be specified to order this product. Refer to standard voltage codes listed below. Approximate Dimensions Reset () # or M DPSO and -Pole and DSO 0-0 Amps Reset..88 DPSG and -Pole 0-0 Amps See page - for replacement contacts. Cross Reference Existing/Replacement Class 89 Existing Device HO HG JO JG KO KG KO KG LO LG MO MG MO MG DPS -Pole starter not available. Suggest -Pole device with auxiliary contact. Miscellaneous Parts and Kits Replacement Device DPSO DPSG DPSO DPSG DPSO DPSG DPSO DPSG DPSO DPSG Description Class & Start-Stop push button itfa Hand-Off-Auto selector switch itf Standard N.C. overload relay contact N.C. and isolated overload relay alarm contacts Overload relay jumper strap 89 DPB 89 DSS 9998 SO 9999 SO 9998 SO $ f Use for 0 to 0 amp starters; for larger sizes, contact your nearest Square D/Schneider Electric sales office. a Does not include holding circuit interloc order auxiliary contact. Ratings Overload Contacts and Auxiliary Contacts Device 9998 SO 9999 SO 9999 R0 & R 9999 D, D0, D & D0 Volts AC Class 89 Replacement Coils Class Volt 9998 Inrush Sealed j 0-0 A & DAt 6 6 $ A & DAt A & DAt 9.00 j CP Discount Schedule, not CP. t Replace asteris with Code from the Coil Table shown below. Coil Table, 60 Hz , 0 Hz Auxiliary Contacts For DPS Startersc Description Class 9999 N.C. / N.C. D D0 D D0 c Auxiliary contacts are available factory installed. Consult local Square D Field Sales Office. $ Pilot Duty AC Only (% Power Factor) Continuous Current Rating Mae Carry & Brea or Less 0 amps amps amps - VA 60 VA amps Code For additional information, reference Catalog # 89CT90R6/97 or D-FAX # 8. V V0 V0 V06 V07 /00 CP jcp Discount Schedule 000 Square D -8 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (60) ! Outside Local Area: (0) 8-900!
4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control
. 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................
More information4.1. Definite Purpose Contactors and Starters. Contents
. Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,
More informationYS Series Contactors YS1N- F11 ****
YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable
More informationRY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz
Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated
More informationDefinite Purpose Contactors and Starters
0 40A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview.............................................. 2 Application Description..........................................
More informationCerti 堵脝 cation Record
Certi 堵脝 cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 214 INDUSTRIAL CONTROL EQUIPMENTMotor Controllers Magnetic
More informationDefinite purpose contactors
Definite purpose contactors Three-pole and four-pole non-reversing DP contactors 600VAC T4 DPBF09 - DPBF12 - DPBF18 - DPBF09 T4 - DPBF12 T4 - DPBF18 T4 DPBF26A DPBF32A DPBF50 DPBF80 Motor Locked Rotor
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More informationManual Starters and Switches Integral Horsepower Types M and T
CLASS 510, 511, 51 INTEGRAL HORSEPOWER STARTERS TYPES M AND T Application Data Types M and T integral horsepower manual starters provide convenient On-Off operation of small single phase, polyphase, or
More informationcontactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.
DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally
More informationXMC0 Series DEFINITE PURPOSE CONTACTORS
DESCRIPTION American Zettlers XMC0 series of Definite Purpose Contactors are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More informationand Refrigeration Institute). CNX Special Purpose Contactors
Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationFuses Special Purpose
Square body 700/1300 VAC Very Fast-Acting 63 200 Amperes Description Littelfuse North American style square body semiconductor fuses provide maximum flexibility in equipment design and ultimate protection
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Definite Purpose Contactors Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability.
More informationSystem pro M compact Miniature Circuit Br eakers Description Features
System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding
More informationXMC0 Series. Definite Purpose Contactors
Description American Zettler XMC0 series of are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air
More information2.1. NEMA Contactors and Starters
3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationTable of Contents. HCC Contactor Nomenclature
Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationTABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:
3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches
More informationESW/PESW. Non-Combination Starters
ESW/PESW Enclosed Non-Combination General WEG offers non-reversing and non-combination magnetic starters up to 75HP at 460Vac (105). Featuring components that meet IEC design standards and UL horsepower
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationStarters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types
Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationSoftstarters Type PSS. Softstarters. General information
General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information4 - Miniature controls
Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More informationHOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1
MERCURY TO METAL CONTACTORS AND RELAYS GLASS SEAL GUIDE RETAINER TEFLON GUIDE MAGNETIC SLEEVE BOBBIN TERMINAL WELD RING CERAMIC INSULATOR ELECTRODE METAL CAP DESCRIPTION MERCURY TO METAL CONTACTOR: The
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationIEC Utilization Categories (Explanation)
IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationTeSys GV2 - GV3 Manual Starters and Protectors
TeSys GV GV Manual Starters and Protectors A stronger, longterm connection Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA 94080670 General Inquiries: (800) 67048 www.stevenengineering.com
More informationBrushless DC Axial Fans
Brushless DC Axial Fans General Specifications Material: Body PBT UL 9V- Fan PBT UL 9V- Insulation Class E Approvals UL, cul Recognized E89 Box Count: x 8 pieces x pieces 9 x pieces 8 x pieces x pieces
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationWell-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940
Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationContactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws
A9 - AF1650 11 Contactors A9 - A110 Maximum UL/CSA horsepower ratings according to UL508 and CSA22.2 No. 14 Includes NEMA sizes 00-3 CE mark Compact space saving design Standard auxiliary contact configurations:
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationJARD by MARS JARD by MARS
Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More information4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.
XMC0 Series Definite Purpose Contactors Description Hongfa s Definite Purpose Contactor XMC0 meets the rigorous demands of the HVAC, refrigeration, heating, data processing, welding, elevators, hoist &
More information2. No tools required for snap-on accessories require that make modification quick and easy.
XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1-Pole, 1-Pole+1Shunt, 1-Pole+1NC, 1-Pole+1NO, 2-Pole, 3-Pole,3-Pole+1NC and 3-Pole+1NO,from
More informationHPS Fusion General Purpose Enclosed Transformer
HPS Fusion General Purpose Enclosed Transformer Our Company Hammond Power Solutions (HPS) was established in 1917 in Guelph, Ontario and has grown from a small family owned business in the short wave radio
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationCross reference. Definite Purpose Contactors
Cross reference Definite Purpose Contactors HOMER Tyco/PU Siemens/Furnas GE Culterhammer Schneider/Square D. Honeywell XMC0 100 42/45 CR45 C25 8910 R82 XMCK 100 45 CR45 C25 8910 R82 Contactors HOMER Schneider/TE
More informationLOW VOLTAGE SWITCHGEAR
LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationJOSLYN CLARK VACUUM CONTACTOR FEATURES
USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More informationXCS Safety Interlock Selection
Steven Engineering-2 Ryan Way-South San Francisco, CA 980-6370-Main Office:(650)588-9200-Outside Local Area:(800)258-9200-www.stevenengineering.com Selection Plastic, Double, Turret Head c, Type, locking
More informationMERCURY TO METAL CONTACTORS AND RELAYS
MERCURY TO METAL CONTACTORS AND RELAYS DESCRIPTION MERCURY TO METAL CONTACTOR: The load terminals are isolated from each other by the glass in the hermetic seal. The plunger assembly, which includes the
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationSoftstarters. Softstarters Power electronic brakes Type PEB
Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)
More informationXMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information
XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1 pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationMove to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers
Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology
More informationLocking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG
Locking Style Spring or Solenoid Locking Two locking mechanisms are available: spring lock with energized solenoid release and energized solenoid lock with spring release. Rigid and flexible in-line actuators
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect
More informationType S Contactors and Starters
Type S Contactors and Starters Class 8536/8502/8736/8702/8810/8811/8812 CONTENTS Description Page Magnetic Contactors and Starters.......................................1 Reversing Magnetic Starters and
More informationVacuum Contactors and Starters
Vacuum s and Starters Size 4 Vacuum.1 Product Description....................................... Application Description.................................... Operation...............................................
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls
More informationHigh Performance Thermal-Magnetic Circuit Breakers 410/520/
High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More information