VACUUM PUMP Midi Keyboard Pump

Size: px
Start display at page:

Download "VACUUM PUMP Midi Keyboard Pump"

Transcription

1 Midi Keyboard Pump Max. vacuum level Max. flow rate Supply air pressure Supply air type : VKX pump -92 kpa ( inhg) VKM pump -85 kpa (-25.1 inhg) : VKX pump 62 Nl/min (2.19 scfm) VKM pump 74 Nl/min (2.61 scfm) : 3~6 bar, Max. 7 bar (43.5~87 psi, max psi) : Dry compressed air Working temperature : -20 to +80 Noise level : A Main Advantages Model-Vacuum Flow VKM61 V K M62 VKX61 VKX62-37 Nl/min - 74 Nl/min - 31 Nl/min - 62 Nl/min Body-type High efficiency Midi vacuum pump (Multi-Nozzle type). Available of individual control. Vacuum filter self cleaning system. Long life time and Low noise level. Easy to install and Compact size (17mm). Lightweight. Built-in check valve. Integrated Vacuum Pump, Air supply & vacuum release control valve, Vacuum Switch & Filter, Blowing flow control valve and silencer in a body. Order No. S - M - Manifold unit E - Manifold unit with central exhaust unit Vacuum Stack 1-1 stack 2-2 stack 3-3 stack 4-4 stack 5-5 stack 6-6 stack 7-7 stack 8-8 stack Valves Air supply control valve A (N. C. :Normal Closed) B (N. O. :Normal Open) C (N. C. :Normal Closed) D (N. O. :Normal Open) E W* Double solenoid valve * Only for DC24V and connector type. VKM62 - M4 - A C N V Voltage Vacuum release control valve - AC 110V - AC 220V - DC 24V Solenoid Terminal 1* - DIN type without lead wire Vacuum switch Non return valve no mark - standard N - Non return valve Sealing no mark V E - standard (NBR) - Viton - EPDM 200 2* - DIN type with lamp without lead wire 3 - Connector type with lamp & 0.3 m lead wire 2B* - DIN type with 2 in 1 BUS cable (Air control v/v + Vacuum release v/v) 3B* - DIN type with 3 in 1 BUS cable (Air control v/v + Vacuum release v/v + Digital switch) * Can not available with double solenoid valve Remark 3 : Available only with DC24V 3B : Available only with DC24V Available only with C or PC, section About BUS cable ( 340, 341) (N. C. :Normal Closed) (N. C. :Normal Closed) (N. C. :Normal Closed) (N. C. :Normal Closed) (P )C - Digital display output 2points, No analog supply M8 4-Pin connector type. (P)G - Digital display output 2points, No analog supply 4-Core 2m Grommet lead wire. (P)GA - Digital display output 2points, Analog supply 5-Core 2m Grommet lead wire. S1 - Mechanical vacuum switch S4 - Flashing LED light display NPN output 2points, No analog supply, 4-Core 1m lead wire. S5 - Flashing LED light display PNP output 1point, No analog supply, 3-Core 1m lead wire. Remark : (P).. Output type : PNP open collector

2 Characteristics Model VKX61 VKX62 VKM61 VKM62 max. vacuum -kpa(-inhg) 92 (27.17) 85 (25.1) Max. vacuum flow (Nl/m)/ each stack air consumption (Nl/m )/each stack 21~24 43~48 15~21 30~42 noise level (dba) Connector Valve weight (g) each stack DIN Valve min hose inner (within 2m) air supply single unit manifold unit Ø vacuum Remark : Manifold unit type weight = each stack weight X N + 5 6g (N: stack) Induce air in liters per minute (Nl/m) Model VKX61 (N) VKX62 (N) VKM61 (N) VKM62 (N) -inhg -kpa Time in seconds to evacuate to vacuum level (sec/l) Model VKX61 VKX62 VKM61 VKM62 -inhg -kpa VACUUM PUMPS The composition of the Midi Keyboard pump 201

3 VACUUM PUMP Midi Keyboard Pump Selectable wide range of valves and switches. DIN type control valve Digital display vacuum switch See page 324~325 Connector type control valve Flashing lamp display vacuum switch See page 322~323 Double solenoid type control valve Electro-Mechanical vacuum switch See page

4 Control valve Connector type / Digital vacuum switch Control valve DIN type / Digital vacuum switch VACUUM PUMPS Control valve double solenoid type / Digital vacuum switch [ Measure unit : mm ] 203

5 Control valve Connector type / Mechanical vacuum switch Control valve DIN type / Mechanical vacuum switch Control valve double solenoid type / Mechanical vacuum switch [ Measure unit : mm] 204

6 Control valve Connector type / Flashing lamp display vacuum swi tch Control valve DIN type / Flashing lamp display vacuum switch VACUUM PUMPS Control valve double solenoid type / Flashing lamp display vacu um switch [ Measure unit : mm] 205

7 Manifold unit Control valve Connector type / Digital vacuum switch Manifold unit Control valve DIN type / Digital vacuum switch [ Measure unit : mm] Manifold unit Control valve double solenoid type / Digital vacuum switch Stack 2stack 3stack 4stack 5stack 6stack 7stack 8stack A (mm)

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK

Vacuum Level. Max Vacuum -Kpa / Hg. Model A B C D E F G H ØI Supply Vacuum Exhaust CV05H / SK CV10H / SK VACUUM VENTURI CV VACUUM VENTURI Anodized aluminum body All metal construction Maximum vacuum of 27 Hg Vacuum flow rates up to 8CFM Single stage technology HSK s include part presence switch R N CV 15

More information

VACUUM PUMP Mini Pump

VACUUM PUMP Mini Pump MINI PUMPS VACUUM PUMP Mini Pump M-Mini Pump Max. vacuum level Max. flow rate Supply air pressure Supply air type Working temperature Noise level :-85 kpa(-25.1 inhg) :220 Nl/min (7.77 scfm) :4~6bar, max

More information

Vacuum pumps/generators Small

Vacuum pumps/generators Small picompact10 Ejector with COAX patented technology. Reduced air-consumption with 30-50% compared to other ejector technologies. Easy to optimize vacuum performance with a varied selection of micro multi-stage

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

SECTION 7 AX SERIES PUMPS

SECTION 7 AX SERIES PUMPS SECTION X SERIES PUMPS EDCO US www.edcousa.net : X PUMPS Z - ZERO BSE G /8 NPSF G / NPSF LRGE CPCITY G / NPSF General Information : Z: Zero Base (No Base) :4 G/8 NPSF Bases :5 - :6 G/ NPSF Bases : - :

More information

Vacuum Accessories. Pneumatic. Section E. Pneumatic. Parker Hannifin Corporation Pneumatic Division Richland, Michigan

Vacuum Accessories. Pneumatic. Section E. Pneumatic. Parker Hannifin Corporation Pneumatic Division Richland, Michigan Vacuum Accessories Section E E 1 Notes 2 Index Contents Convum Filters... 4-5 Convum Silencers... 6 Silencer (Flow Thru)... 7 ASN Series Air Line Mufflers... 8 E 3 (Revised 10/13/04) Ordering Information

More information

LEM. mini-modules compact integrated vacuum pumps. US3

LEM. mini-modules compact integrated vacuum pumps.   US3 mini-modules compact integrated pumps LEM TM www.coval.com US3 LEM LEM series: mini-module pressure OUT IN 2 exhaust TM certified quality management system All industrial functions integrated into the

More information

Multi-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications

Multi-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications Multi-Stage Ejectors Suction rate from 332 l/min to 2,370 l/min Suitability for Industry-Specific Applications Applications Multi-stage ejector for handling of cardboard, packing materials, insulating

More information

LEM. mini-modules compact integrated vacuum pumps. US5

LEM. mini-modules compact integrated vacuum pumps.  US5 mini-modules compact integrated pumps LEM TM www.coval.com US5 LEM LEM Series: Mini-Module pressure OUT IN 2 exhaust TM certified quality management system 40% energy savings (on average, see p.5). No

More information

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm > Series E valves and solenoid valves Series E valves and solenoid valves 5/-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm Series

More information

mini-modules compact integrated vacuum pumps LEM

mini-modules compact integrated vacuum pumps LEM mini-modules compact integrated pumps LEM TM www.coval.com LEM LEM series: mini-module pressure OUT IN 2 exhaust TM All industrial functions integrated into the mini-module Efficient communication for

More information

Vacuum Automation 2.1. The future depends on good product choices

Vacuum Automation 2.1. The future depends on good product choices Vacuum Automation 2.1 The future depends on good product choices Optimising controls 458 459 Optimising controls Introduction...460 Vacuum switches...462 Valves...478 Regulators...488 Automatic energy

More information

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =

More information

Valves and Solenoid valves Series E 2/

Valves and Solenoid valves Series E 2/ CATALOGUE > Release 8.6 > Series E valves and solenoid valves Valves and Solenoid valves Series E 5/-way monostable/bistable - 5/3 CC CO CP With outlets on the body - For individual or manifold assembly

More information

PD GRIPPER.

PD GRIPPER. PD GRIPPER www.pdgripper.com PDG500 Dimension Weight Air consumption Connection Mounting Material Technical data for PDG500 00x50x05 mm. kg 00 Nl/min /8, Ø8 mm 4 x M8, profile 90x45 (CC45) aluminum, rubber,

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

Vacuum Generators. Section B.

Vacuum Generators. Section B. Section www.parker.com/pneu/vacgen 2 asic Generator Selection How to Select a Generator 4-9 Inline : Single Stage MCA, CV, CV-CK MCA is lightweight generator that can be located directly on the cup fitting

More information

Simple venturis, series GVP

Simple venturis, series GVP Simple venturis, series GVP 5-bar compressed air network 45 13 5 35 L1 Exhaust D1 L 1/4 gas, 6x8 quick-connect or 4x6 quick-connect D 30 Connection for options 6 Vacuum 1/ gas Vacuum generators in series

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

store.norgren.com 18D Pneumatic Rapid delivery order today Models Accessories 1 30 bar For further information

store.norgren.com 18D Pneumatic Rapid delivery order today Models Accessories 1 30 bar For further information store.norgren.com Electro-mechanical pressure switch 18D Pneumatic 1 bar Gold-plated contacts High cycle life Vibration resistant to 15 g Microswitch approved by UL and CSA Intrinsically safe operation

More information

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum 3 Port Direct Operated Poppet Rubber Seal Series 307 Large Flow Capacity, yet Compact Size. Dimensions (W X H X D) 30 X 54.5 X 33 307 Nl/min 206.02 or more, 1/4 Low Power Consumption /VO307 4.8W DC/Standard

More information

Vacuum generation Compact ejectors

Vacuum generation Compact ejectors Energy saving function by integrated pressure control saves up to 5 % of energy q = Vacuum connection z = Compressed air connection Product notes s = Exhaust outlet Check valve with wire mesh to keep out

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 General Series 2200 1 Series 2200 Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP 12 = 24 VDC NPN Weight gr. 67 SHORT FUNCTION CODE "A" Serie Solenoid 2200-S-GB valves - Spring "OPTYMA32-S"

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

w w w. p d g r i p p e r. c o m

w w w. p d g r i p p e r. c o m CATALOGUE 8.0 www.pdgripper.com PDG500 Technical data for PDG500 Dimension Weight Air consumption Connection Mounting Material 00x50x05 mm. kg 00 Nl/min /8, Ø8 mm 4 x M8, Profile 90x45 (CC45) Aluminum,

More information

VACUUM PUMP P5010. Profit from new vacuum technology

VACUUM PUMP P5010. Profit from new vacuum technology VACUUM PUMP P5010 COAX THE NEXT DIMENSION IN VACUUM TECHNOLOGY Profit from new vacuum technology Patented COAX push-in technology Efficient use of energy Outstanding performance Slim and modular design

More information

MICRO EJECTORS CONTENTS

MICRO EJECTORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS GME05, GME07, GME10 Series Featrues 679 Specifications 680 Order Codes

More information

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C Technical details Temperature range Medium + C... +0 C Filtered, oil-free and dried compressed air according to ISO 8-:00, Class ::, instrument air, free of aggressive additives. Alternatively the pressure

More information

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves. ME12, ME25, ME60 Specifications Micro ejectors Media Operating pressure range MPa [psi.] Operating temperature range C [ F] Nozzle diameter Note mm [in.] kpa [in.hg] flow rate Note R/min [ft. 3 /min.]

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM- Features and Benefits Solenoid-Actuated Vacuum Generators Types VADM-... / VADMI-... l Integral Filter, Silencer, Manual Override l Integral Solenoid Valve for Controlling Air Supply l Vacuum Range up

More information

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right Manifold system Manifold plate Valve ports V6 V6 V62 Model kg Model kg Model kg 2 2222,23 3 2223,28 4 2224,6 6 2226,86 8 2228, 222,36 2 2222,6 4 2224,86 6 2226 2, 8 2228 2,36 2 2222 2,6 2222,28 2223,45

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv) Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/2 3300 Nl/min (3.35 Cv) Order code Series and function M-22-310-HN-12 Standard coils 1) 11 = 12 V DC,,2 W 12 = 2 V DC,,2 W 22 = 2 V AC,

More information

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold Compact Electro-Pneumatic Regulator Series ITV How to Order For single unit and single unit for manifold ITV N Q Pressure range. MPa MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector N S L

More information

BKUA002 Ver.1.0. Vacuum MICRO EJECTOR. INSTRUCTION MANUAL Ver.1.0

BKUA002 Ver.1.0. Vacuum MICRO EJECTOR. INSTRUCTION MANUAL Ver.1.0 BKUA002 Ver.1.0 MICRO EJECTOR INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Solenoid Plug connector Manual override Internal circuit DC5V, DC6V, DC12V, DC24V (GA010LE1, GAV010LE1-11)

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Vacuum Generators. Catalogue Edition 2

Vacuum Generators. Catalogue Edition 2 Vacuum Generators Catalogue Edition 2 Switch Options S = SK = The fixed switch option is normally open and changes position at 12 Hg The adjustment of the SK model switch is between 6-16 Hg Features: Anodized

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company Electro-Pneumatic Devices Valves and Positioners The Drive & Control Company Electro-Pneumatic Devices Dynamic precision from Rexroth Why choose Rexroth E/P s? Rexroth electro-pneumatic pressure control

More information

AVL SERIES. Technical Specifications. Compressed Air Loaders. Features

AVL SERIES. Technical Specifications. Compressed Air Loaders. Features Material Handling Process Cooling Temperature Control Size Reduction Compressed Air Loaders Technical Specifications Features (Shown with Optional Sight Glass) AVL loaders are designed to provide trouble-free

More information

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv) Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to 0.966 Cv) Order code Series and function KM-09-510-HN-442 Standard coils HN at ports 2 + 4 HN at ports 1, 3

More information

Compact design suitable for use in reduced mounting space. CONTROL > Directly operated solenoid valves Series PN GENERAL DATA

Compact design suitable for use in reduced mounting space. CONTROL > Directly operated solenoid valves Series PN GENERAL DATA > Directly operated solenoid valves Series PN Directly operated solenoid valves Series PN 3/-way Normally Closed (NC). The solenoid valves can be mounted on a single base (with M5 ports) as well as on

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES S E R I E S P Directly operated mini-solenoid valves Series P 3/ way N.C. or N.O. Ports M5 (for single base) Cartridge ø 3 and 4 (for manifold) Note: All the serie P electrovalves are basic in DC. For

More information

Micro-venturis, series GVA

Micro-venturis, series GVA Micro-venturis, series GVA Reference V : vacuum outlet Coupling M F, 6 mm deep or Quick-connect coupling, tube 4 mm dia. or Male coupling, 4 mm dia.,. mm long ø. 4... Version GVA -- 44 GVASIL or GVASPO

More information

Vacuum Ejector. Adaptable for manifold application

Vacuum Ejector. Adaptable for manifold application Vacuum Ejector Series ZM ZX All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off Fastvac Mini Series: VP01QR-60 VP01QR-60H/24vDC Standard

More information

Series ITV1000/2000/3000

Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV// How to Order [Option] RoHS ITV S Model type type type Pressure range 5 MPa MPa.9 MPa CE compliant Nil Q CE compliant Note) Refer to pages, 5, and 6 for information

More information

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type 5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type COMPACT SIZE AND LIGHT WEIGHT LARGE FLOW CAPACITY LOW POWER CONSUMPTION DESIGNED FOR NON-LUBRICATED SERVICE DV000 Symbol Single DS330/ How

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv) Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/4 1300 and 1580 Nl/min (1.321 and 1.606 Cv) Order code Series and function M-07-310-HN-442 Standard coil HN at port 2 + 4 HN at port

More information

Solenoid valves "ENOVA" Series 2300

Solenoid valves ENOVA Series 2300 Solenoid valves "ENOVA" Series 300.04 Series 300 Solenoid valves "ENOVA".05 Solenoid valves "ENOVA" Series 300 Solenoid - Differential (Monostable) 5/ 3eC.5.00.36.v ELECTRICAL CONTACTS 0=STANDARD-only

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Operating pressure: -4.5-74 psi electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display Units displayed Switching logic Ambient

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational

More information

Solenoid valves "OPTYMA32-S" General. Series 2200

Solenoid valves OPTYMA32-S General. Series 2200 1 Solenoid valves "OPTYMA32-S" General Series 2200 1 Series 2200 Solenoid valves "OPTYMA32-S" Solenoid - Spring 2241.52.00.39.v v VOLTAGE 02 = 24 VDC PNP Weight gr. 67 SHORT FUNCTION CODE "A" Operational

More information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range 000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power

More information

Large Size Vacuum Module:

Large Size Vacuum Module: Large Size acuum Module: System/acuum Pump System Z Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for

More information

Servo-operated 2/2-way solenoid valves Type EV220A

Servo-operated 2/2-way solenoid valves Type EV220A Data sheet Servo-operated 2/2-way solenoid valves Type is a compact servo-operated 2/2-way solenoid valve program, especially designed for use in machines and equipment with limited space. Features and

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2

More information

121 1/8 NPT Solenoid and pneumatic valves size 0,86 in

121 1/8 NPT Solenoid and pneumatic valves size 0,86 in 121 1/8 NPT Solenoid and pneumatic valves size 0,86 in General Features Construction: spool type Body size: 0,86 in Ports: 1/8 NPT Body material: technopolymer Single use: Yes Manifold use: No Available

More information

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED BC 4.3 Gas Tight Dampers GTD-GB40-B-E Table Of Contents S. No Description Page No 1 Gas Tight Damper with Electric Drive 1 2 Electric Drive - Details 2-3 3 Gas Tight Damper with Pneumatic Drive 4 4 Pneumatic

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

Series P directly operated solenoid valves

Series P directly operated solenoid valves > Series P solenoid valves CATALOGUE > Release 8.7 Series P directly operated solenoid valves 3/-way NC and NO. The solenoid valves can be mounted on a single base (with M5 ports) as well as on manifolds

More information

Catalog 080-/USA Notes Vacuum Control Valves

Catalog 080-/USA Notes Vacuum Control Valves Vacuum Control Valves Section Catalog 080-/USA Notes Vacuum Control Valves Catalog 080-/USA Index Vacuum Control Valves VA0 Vacuum Control Valves for Centralized Vacuum Systems VA0PSV & VA0PSP, -Port,

More information

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED BC 4.2 Tunnel Ventilation Dampers TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S Type : Tunnel Ventilation Fire Damper Model : TVFD-GB-40-B;TVFD-SB-40-B Fire Rating :

More information

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv) Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented

More information

Angle Seat Valve /2" up to 3"

Angle Seat Valve /2 up to 3 1/ up to up to 428 F Pneumatically operated angle seat valve for the control of neutral and aggressive gases, liquids and steam. Compact design For temperatures from -22 F up to +428 F Working pressure

More information

Ejector Valve Unit Series ZYY/ZYX

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

80g. 10.5mm. Width: Weight: Complex Vacuum Generator with Lightweight, Compact Body and High Vacuum Cycle Vacuum Generator VX Series

80g. 10.5mm. Width: Weight: Complex Vacuum Generator with Lightweight, Compact Body and High Vacuum Cycle Vacuum Generator VX Series EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator with Lightweight, Compact Body and High Vacuum Cycle Vacuum Generator Series 188 Lightweight and compact body meeting market needs.

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm) VACUUM SWITCHES VAS VACUUM SWITCH Diaphragm vacuum switch Compact size Lightweight Inch port sizes 5/32, 1/4 & 5/16 Metric port sizes 4, 6 & 8mm Fully adjustable VAS 10 06 Series Body Size 10 Vacuum Port

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Pressure Sensors. Section C. Pneumatic. Sensors.

Pressure Sensors. Section C. Pneumatic. Sensors. Section C www.parker.com/pneu/sensors Parker Hannifin Corporation Division Pressure Cross Reference Control Components Technical Data Pressure Unit Table Units Units Pa bar PSI kgf/cm 2 atm mm H 2 O in

More information

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only. Precision Regulator Series IR//3 5 Precision Regulator Series IR//3 Features Precise air pressure regulator for instrument applications. Three body sizes available. Pressure unaffected by supply pressure

More information

Vacuum Ejector. Series ZM

Vacuum Ejector. Series ZM Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Vacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S

Vacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S CKD Actuators Pneumatic Valves Pneumatic Auxiliary Components Pneumatic Auxiliary Components (Main Line Unit) Pneumatic Filter, Regulator, Lubricator (F.R.L. Unit) Related Pneumatic Products DD Actuator

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread

Diaphragm pressure switches up to 42 V with brass housing. Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) 1) Male thread 0167 Diaphragm pressure switches with brass housing Brass housing M3 screw terminal Overpressure safety up to 500 psi (35 bar) Adjustment range tolerance at room temperature Male thread NO : NC : 36 Screw

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

Series ZM Applications

Series ZM Applications Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer Type Ejector Ambient temperature min./max. + C / + C Medium temperature min./max. + C / + C Working pressure min./max. 3 bar / 6 bar Medium Compressed air Max. particle size µm Oil content of compressed

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

RCM - Direct Reading Flowmeters

RCM - Direct Reading Flowmeters Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread

Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) 1) Male thread M.3 0166 Diaphragm pressure switches with M3 screw terminal Made of zinc-plated steel (CrVI-free) M3 screw terminal Overpressure safety up to 4,350 psi (300 bar) Adjustment range tolerance at room temperature