SPRAYSHOP ANALIZER IMPORTANT : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION

Size: px
Start display at page:

Download "SPRAYSHOP ANALIZER IMPORTANT : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION"

Transcription

1 : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION This equipment must not be operated by any person with a heart condition or is fitted with a pacemaker device. REMEMBER ELECTRICITY AND WATER DO NOT MIX!!! KEEP UNIT CLEAR OF ALL KNOWN LIQUID SOURCES IMPROPER USE CAN CAUSE ELECTRIC SHOCK!!! NEVER USE THE ANALIZER NEAR WATER OR SOLVENT BASED LIQUIDS NEVER USE NEAR FLAMMABLE PAINTS, ADHESIVES OR POWDERS. IF IN DOUBT CONSULT THE RELATIVE MANUFACTURERS DATA SHEET. DO NOT WEAR RUBBER GLOVES OR RUBBER SOLED SHOES WHEN OPERATING THE ANALIZER. WEAR LEATHER SOLED SHOES ONLY THIS WILL ASSIST IN THE DISSAPATION OF STATIC CHARGES WITHIN THE OPERATOR 1

2 The Analizer has been designed specifically to test High Voltage Outputs from the tips of Electrostatic Spray-guns of both Paint and Powder types. Contact your Suppliers Technical Department if you have any Doubt about the correct usage of this Analizer Always consult the Instruction / Operating Manuals of the Electrostatic equipment being tested. Particular attention should be made to their Safety Sections. ALWAYS PREPARE YOUR TEST AREA WITH ABSOLUTE SAFETY IN MIND The Analizer must never be used for testing electricity or High Voltage / High Current outputs. When testing for High Voltage outputs, the High Voltage probe should be held by the Black Handle Grip ONLY NEVER hold the polished Sphere (Ball) with you hands RISK OF ELECTRIC SHOCK When testing with the High Voltage Function, ALWAYS ensure the Analizer is positioned on a level, uncluttered surface. DO NOT HOLD THE ANALIZER IN YOUR HANDS WHEN CARRYING OUT THE HIGH VOLTAGE TEST FUNCTION 2

3 : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION INFORMATION The High Voltage Test Function has been Calibrated in conjunction with the following equipment:- Advance Hivolt 100Kv High Voltage, Digital Volt Meter Type: DVM 100/20 Serial No Calibration Certificate No. 182 dated 21 st May 2001 The Temperature Reading has been calibrated in conjunction with the following equipment: Digitron Instruments Thermocouple Simulator Type K NiCr/NiAl Serial No. 022/08 Calibration Certificate No dated 1 st November 2000 The above instruments have been tested to manufacturer s specifications and calibration is traceable to National Standards. The High Voltage, Digital Volt Meter above relies for its accuracy on a 1000M ohm input Test Resistor. This Test Resistance (impedance) is regarded as an Industry Standard. The input resistance (impedance) is identical to that of the Hand Held High Voltage Test Probe of the Sprayshop Analizer. THE HIGH VOLTAGE TEST FACILITY ON THIS METER IS INTENDED TO BE A GUIDE ONLY. If the Sprayshop Analizer is being used in the Temperature Mode whilst in the location of any equipment producing electromagnetic interference loss of functionality may occur. TO OVERCOME THIS POSSIBLE LOSS, IT IS ADVISABLE TO USE THIS INSTRUMENT IN AN AREA FREE OF HIGH ELECTROMAGNETIC INTERFERENCE. 3

4 It is possible that the Kv Output readings may not compare with those contained in the equipment manufacturer s Specifications / Data Sheets. However, this does not necessarily mean the equipment under test is faulty. Equipment manufacturers utilise differing electronics systems. True output readings, can only be obtained under laboratory conditions. For guidance on the output Kv readings of your particular equipment, please consult your main distributor for further information. It is important that, should you have a query relating to their equipment, you always inform them that you are using a High Voltage Test Resistance (impedance) of 1000M ohm. (The Manufacturer s Technical Department should then be able to advise the expected readings at the tip of the Spraygun). Usually the High Voltage Test Probe should only be used when testing High Voltage Outputs from the tip of the Spraygun. (Equipment manufacturers utilise different internal resistances (impedance) which will affect the overall HV output). It is not advisable to test directly, the generator output with this probe Contact your supplier for further information It is suggested that the high voltage output readings be monitored frequently. Any decline in operating efficiency will then be noted and the appropriate action may be taken. The High Voltage Probe can also be utilised to identify the electrostatic field so as to aid the positioning of automatic guns, and the tracing of high voltage leakage caused by the use of metallic powders - Refer to your supplier. When all tests have been completed, please ensure the multi-function switch is set to the OFF position. Ensure PP3 battery is disconnected if the unit is not to be used for some time. Use only good quality PP3 batteries. The Sprayshop Analizer should be re-calibrated annually to ensure accurate readings refer to your supplier. 4

5 FEATURES: Audible Signal for Earth / Ground Detection Digital High Voltage Meter Digital Thermometer OPERATING INSTRUCTIONS Earth / Ground / Continuity Testing Insufficient object earthing / grounding or high surface resistance are often responsible for poor powder attraction and therefore priority should be given to improving the earthing / grounding of the article to be sprayed electrostatically. Insert the shrouded test leads into their corresponding sockets (Red and Black) Turn the multi-function switch to Earth / Temp position. The display will be activated to the C scale. DISREGARD DISPLAY FOR THIS FUNCTION. To test that the audible alarm is operating, press the test lead probes together. A high pitched signal should now be heard. To carry out earthing / grounding / continuity tests progressively, move test probes along the various connecting points of the earth / ground path from the generator through to the hanging jigs and finally to the articles to be sprayed. REMEMBER - ONLY WHEN THERE IS SUFFICIENT EARTH / GROUND PATH between the two test probes will a high pitched audible signal be emitted. Spraygun Earthing / Grounding Occasionally, when spraying electrostatically, the operator may suffer shocks if the earth / ground connections in the spraygun or generator become faulty. To confirm that the gun handle earthing / grounding is satisfactory, press one test probe to the metal gun handle and the other to the generator earth / ground point (with gun still connected). If the earthing / grounding to the gun is sufficient, the audible signal will be heard. If no signal is attained, further investigation may be necessary. Refer toyour supplier if further assistance is required. NB Always ensure electrostatic generator is earthed / grounded correctly from the mains supply. If using a mains extension lead, check that lead has earth / ground conductor. Some manufactured leads do not! 5

6 Digital Thermometer The Digital Thermometer will operate up to 300 C when used in conjunction with the surface contact probe (supplied as standard). Temperature Testing Remove shrouded test leads from sockets. Turn the multi-function switch to the Earth / Temp position. The display will stabilise to the C (centigrade) scale. Disregard the LCD reading when no sensing probe is inserted. Using Surface Contact Probe Insert probe into Green K Socket. The LCD reading should now rise to room temperature (approx), Touch the probe to the object to be powder coated. Wait for the LCD reading to stabilise to read the surface temperature. This surface contact probe will be found to be very useful when coating large items where considerable heating of the mass has to take place before the object reaches powder curing temperatures. Other probes are available for monitoring the temperature through tunnel ovens, hot / cold spots in box ovens and air temperature. For example, by attaching the Thermocouple wire to an item passing through a tunnel oven and noting the temperature every 30cm s (12 ), it is possible to calculate if the oven is operating at the correct temperature, for the correct period of time, to enable satisfactory powder curing. Contactyour suppliert for further information. 6

7 High Voltage Testing If the charging voltage at the spraygun electrode is low, the generator, and / or its associated cable, (if applicable) may be at fault. To maintain a check on this, a high voltage test probe is supplied and can be used as follows: Remove shrouded test leads / temperature probes from meter. Assemble high voltage probe. Turn the multi-function switch to the volts (KV) position. ALWAYS consult the Instruction / Operating Manual(s) of the Electrostatic Equipment being tested BEFORE commencing a High Voltage Test. PAY PARTICULAR ATTENTION TO THEIR SAFETY SECTION Ensure High Voltage Generator / source is switched OFF BEFORE connecting Test Probe / Clip. 1. Connect single black earth / ground lead, using crocodile / alligator clip, to the generator earth / ground (or known earth / ground). Important - Always ensure that a good connection is made otherwise severe damage may result. 2. Plug in single red lead with jack plug into the available socket on the Analizer. - Always connect earth / ground black lead crocodile / alligator clip - before high voltage red lead otherwise severe damage may result. Switch on generator (ensure material supply is off). Switch on static supply. Pull gun trigger (static should now be available on gun tip). Hold the BLACK HAND-GRIP ONLY and place the polished sphere to the gun tip. Wait for LCD reading to stabilise and take note. NEVER hold the polished sphere (ball) with your hands RISK OF ELECTRIC SHOCK Switch off generator when satisfactory reading attained. Reading will be in Kilo-volts. 7

OWNER'S MANUAL RED LINE EZ50

OWNER'S MANUAL RED LINE EZ50 OWNER'S MANUAL RED LINE EZ50 electrostatic powder coating gun Congratulations on your purchase of the RED LINE EZ50 electrostatic powder EZ50 coating gun. You could be a serious hobbyist or a first time

More information

MICROFLOCKER. Operating Instructions

MICROFLOCKER. Operating Instructions MICROFLOCKER Operating Instructions Campbell Coutts Ltd Unit 7 Tower Industrial Estate, Tower Lane Eastleigh SO50 6NZ, Hampshire, England sales@flocking.biz www.flocking.biz tel:+44(0) 23 80613700 fax:+44(0)

More information

OWNER'S MANUAL RED LINE NC kv electrostatic powder spray system

OWNER'S MANUAL RED LINE NC kv electrostatic powder spray system OWNER'S MANUAL RED LINE NC 201 100 kv electrostatic powder spray system INTRODUCTION Congratulations on your purchase of the RED LINE NC 201 powder coating machine. You have purchased one of the finest

More information

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge

More information

Electrostatic System Checks

Electrostatic System Checks Instruction Sheet P/N Electrostatic System s WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.

More information

OWNER'S MANUAL RED LINE ProCoater PC201IF 100 kv electrostatic powder spray system

OWNER'S MANUAL RED LINE ProCoater PC201IF 100 kv electrostatic powder spray system OWNER'S MANUAL RED LINE ProCoater PC201IF 100 kv electrostatic powder spray system Tel: (91 22) 242477 / 2424787 Fax: (91 22) 6646696 INTRODUCTION Congratulations on your purchase of the RED LINE ProCoater

More information

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015) MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015) ALWAYS CONNECT CABLES PRIOR TO POWERING ON THE INSTRUMENT 1. HOLIDAY DETECTOR FUNCTION The Tinker & Rasor Model AP/W Holiday Detector

More information

Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS

Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS Can be used in accordance with: Australian Standard AS3894.1 ASTM G62, ASTM D5162, ASTM D4787, NACE RP0274, NACE SP0490,

More information

Dielectric Withstand Tester

Dielectric Withstand Tester Dielectric Withstand Tester Model HT-20KVPac 0-20,000 Volts AC Output Instruction Manual i Dear Customer: Congratulations! Compliance West USA is proud to present you with your Dielectric Withstand Tester.

More information

The D.E. Stearns Company Shreveport Louisiana U.S.A. D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HIGH VOLTAGE HOLIDAY DETECTOR

The D.E. Stearns Company Shreveport Louisiana U.S.A. D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HIGH VOLTAGE HOLIDAY DETECTOR D. E. STEARNS MODEL 14/20 REGULATED 800-35,000 VOLT HIGH VOLTAGE HOLIDAY DETECTOR 1. HOLIDAY DETECTOR FUNCTION The D.E. Stearns Model 14/20 Holiday Detector is an all-purpose electrical inspection instrument

More information

UP100AC INSTRUCTION MANUAL

UP100AC INSTRUCTION MANUAL UP100AC AC/DC Charger INSTRUCTION MANUAL 100W 10A TABLE OF CONTENTS Introduction... 2 Special Features... 4 Warning and Safety Notes... 6 Lithium Battery Connection Diagram... 10 Operation Diagram - Homepage...

More information

Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS

Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS Operator s Handbook For Compact High Voltage DC15 & DC30 POROSITY (HOLIDAY) DETECTORS Can be used in accordance with: Australian Standard AS3894.1 ASTM G62, ASTM D5162, ASTM D4787, NACE SP0274, NACE SP0490,

More information

TCS 1200 Portable Temperature Calibrator

TCS 1200 Portable Temperature Calibrator TCS 1200 Portable Temperature Calibrator Instruction Manual MM 2 CONTENTS DESCRIPTION EMC Information Electrical Safety Environmental Ratings Insert Warning Health & Safety Instructions Guarantee Cautionary

More information

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA. An ISO 9001:2008 Company 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER FEATURES : MODEL KM 7015 IN Microprocessor controlled Menu driven. Variable High Voltage : 500 V ~ 15 kv DC. Measuring 30 Insulation

More information

BATTERY OPERATED DIGITAL MILLI-OHMMETER

BATTERY OPERATED DIGITAL MILLI-OHMMETER BATTERY OPERATED DIGITAL MILLI-OHMMETER C 1 P 1 P 2 C 2 MAX. DC20V MICROPROCESSOR CONTROLLED AC DC HOLD M A X M I N AUTO-HOLD Hz mv km ka ms DIGITAL MILLIOHM METER 2000 200.0 20.00 2000m Test Current Range

More information

HIGH VOLTAGE PROXIMITY DETECTOR

HIGH VOLTAGE PROXIMITY DETECTOR HIGH VOLTAGE PROXIMITY DETECTOR An ISO 9001:2008 Company Model 275 HP (Upto 275KV) / 500 HP (Upto 500KV) The 275HP / 500HP is a HIGH VOLTAGE proximity detector. 275HP has eight voltage detection settings

More information

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1 BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for

More information

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions 4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve

More information

Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS

Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS Can be used in accordance with: Australian Standard AS3894.1 ASTM G62, ASTM D5162, ASTM D4787, NACE SP0274, NACE TM0186,

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd. Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

SP904/3/4/5/7/8/10/11/13 Integrated Wireless Side Warning System

SP904/3/4/5/7/8/10/11/13 Integrated Wireless Side Warning System Fig 1 Operation Guide & Recommended Fitting Instructions. SP904/3/4/5/7/8/10/11/13 Integrated Wireless Side Warning System The SP904 integrated is a fully flexible, easily expandable vehicle blind spot

More information

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A English Fitting Instructions: Street Triple from VIN 560477 and Street Triple R from VIN 560477 A9808113 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of

More information

ACL 780/781 Economy Combo Tester

ACL 780/781 Economy Combo Tester ACL 780/781 Economy Combo Tester OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. 840 W. 49 th Place Page 1

More information

Earth-Rite MGV Mobile Grounding Verification. White Paper. Author Details: Page 1 of 5

Earth-Rite MGV Mobile Grounding Verification. White Paper. Author Details:   Page 1 of 5 White Paper Author Details: Mike O Brien, Head of Marketing and Sales for Newson Gale If you have any questions relating to the topics discussed in this article, you can contact Mike directly at: mike.obrien@hoerbiger.com

More information

Operator s Handbook for. Compact. High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS. Can be used in accordance with: Australian Standard AS3894.

Operator s Handbook for. Compact. High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS. Can be used in accordance with: Australian Standard AS3894. Operator s Handbook for Compact High Voltage P20 & P40 POROSITY (HOLIDAY) DETECTORS Can be used in accordance with: Australian Standard AS3894.1 ASTM G62, ASTM D5162, ASTM D4787, NACE SP0274, NACE TM0186,

More information

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS MARTINDALE ELECTRIC Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web:

More information

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE 1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE INST045 Doc 2.00 CONTENTS General Information...2 Operating Environment...6 Features...7 Installation Instructions...8 Inverter Ground and Remote Sense

More information

MICROWAVE CHECKER. User Manual Issue 1.4. e: w: Microwave Checker ISSUE 1.4

MICROWAVE CHECKER. User Manual Issue 1.4. e: w:  Microwave Checker ISSUE 1.4 MICROWAVE CHECKER User Manual Issue 1.4 F i rst Stop Safety 1 1 Glaisdale Road N o rthminster Business Park York YO26 6QT t : 01904 791050 f : 01904 780054 e: info@firststopsafety.co.uk w: www.firststopsafety.co.uk

More information

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration

More information

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale: Other products from Martindale: 18th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s Kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital

More information

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR D. E. Stearns Company, Shreveport, Louisiana U.S.A. OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED 800-35,000 VOLT HOLIDAY DETECTOR 1. HOLIDAY DETECTOR FUNCTION The D.E. Stearns Company Model

More information

KEWTECH. KT56 digital multi function tester. Instruction manual

KEWTECH. KT56 digital multi function tester. Instruction manual KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating

More information

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT CM69 TRMS AC EARTH LEAKAGE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings

More information

Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current

Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current The Gi50/32/SA withstands fault surges of up to 120a, and is designed for installations connected to shore supplies protected by an

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

USER MANUAL: JCI 147 Faraday Pail

USER MANUAL: JCI 147 Faraday Pail John Chubb Instrumentation Ltd Unit 30, Lansdown Industrial Estate, Gloucester Road, Cheltenham, GL51 8PL, UK. Tel: +44 (0)1242 573347 Fax: +44 (0)1242 251388 email: jchubb@jci.co.uk USER MANUAL: JCI 147

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

MICROCARE 3 PHASE INVERTER MANUAL

MICROCARE 3 PHASE INVERTER MANUAL 3 PHASE INVERTER MANUAL 1 Contents 1. INTRODUCTI... 3 2. SAFETY INSTRUCTI... 4 3. SYSTEM DESCRIPTI... 6 4. WIRING DIAGRAM... 9 5. INVERTER OPERATI... 10 6. INVERTER CLUSTER PROGRAMMING... 13 7. CLUSTER

More information

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter INSTRUCTIONS PARTS LIST 308 217 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. B Supersedes A PRO ES Test Fixture, High Voltage Test Probe, & KV Meter To Test

More information

Galvanic Isolator. Instruction Leaflet

Galvanic Isolator. Instruction Leaflet G i Galvanic Isolator Gi120-P-SA Instruction Leaflet ote: The isolator is suitable for shore supplies that are protected by an RCD (Earth Leakage Circuit Breaker) with a trip current not exceeding 30mA,

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

Why Electric Safety Standards

Why Electric Safety Standards Paul Haggarty Why Electric Safety Standards To protect patients and caregivers from electrical shock To prevent electrical interference between instrument sub-systems/circuits To prevent electrical interference

More information

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS Instructions for: Digital Multimeter - 6 Function MOdel No: MM19.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

More information

Electrical Safety Part II

Electrical Safety Part II Electrical Safety Part II Check the condition of any equipment and use insulated leads Before you connect any equipment to the mains voltage always check that the equipment is not visibly damaged and that

More information

BASIC ELECTRICAL MEASUREMENTS By David Navone

BASIC ELECTRICAL MEASUREMENTS By David Navone BASIC ELECTRICAL MEASUREMENTS By David Navone Just about every component designed to operate in an automobile was designed to run on a nominal 12 volts. When this voltage, V, is applied across a resistance,

More information

Holiday Detector Data Sheet / Instructions

Holiday Detector Data Sheet / Instructions Paint Test Equipment Holiday Detector Data Sheet / Instructions Holiday Detector Information ISO 29601: Paints and varnishes. Corrosion protection by protective paint systems. Assessment of porosity in

More information

MODEL No s: PP3, PP3K

MODEL No s: PP3, PP3K instructions for: Power PROBE 3 12-24v MODEL No s: PP3, PP3K Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

Technical Description

Technical Description Technical Description LUL, 73 Stock Refurbishment Heating, Ventilating & Air-conditioning Multi-stage Thermostat for Saloon 0.1 19-May-02 ISSUED FOR DISCUSSION FK DC Rev. Date Description By Check Copyright

More information

I I e k ill L ill. INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER BESANTEK BST-ELC01 INSTRUCTION MANUAL

I I e k ill L ill. INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER BESANTEK BST-ELC01 INSTRUCTION MANUAL = = = = - - - BESANTEK - - BST-ELC1 INDUSTRIAL DIGITAL EARTH LEAKAGE CIRCUIT BREAKER and 3 PHASE ROTATION TESTER EARTH DIGITAL INDUST RIAL ELCB HAS OT ATl ONTE O C, 1:. : ==== === ;... P E R STE R ==!

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82315 REL CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this

More information

DIGITAL RCD(ELCB) TESTER

DIGITAL RCD(ELCB) TESTER INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.

More information

EC225 Power Control System

EC225 Power Control System 1 Key Features 200W (~16A) combined Power Converter / Battery Charger - Converts the 230V mains supply into 12v DC power to run the leisure equipment and charge the battery using an intelligent two-stage

More information

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied:

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied: English Fitting Instructions: Trophy and Trophy SE A9808015 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of Triumph's use of proven engineering, exhaustive

More information

Oil Test Cell Catalog No

Oil Test Cell Catalog No AVTM670511a Rev A June 2005 Instruction Manual Oil Test Cell Catalog No. 670511 HIGH VOLTAGE EQUIPMENT Read this entire manual before operating. Aparato de Alto Voltaje Antes de operar este producto lea

More information

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. 1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions. KYORITSU will not accept liability for any damage or injury caused by misuse

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

VAN DE GRAAFF GENERATORS - 400kV

VAN DE GRAAFF GENERATORS - 400kV VAN DE GRAAFF GENERATORS - 400kV EM4133-101 220/240 V.AC. with earth. 50/60 Hz. 300mm diameter ball generates about 400kV DESCRIPTION: The I EC 300mm diameter Van De Graaff Generator is a modern, compact

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL

PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL 72-7400 PRECISION MILLI/MICRO OHMMETER INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 3 EMC 4 Safety 5 Installation 6 Connections 7 Front Panel Controls 8 Operation 9 Maintenance 12

More information

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA  KEWTECH Distributor Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA www.kewtechcorp.com KEWTECH 92-1618 04-03 KEWTECH KT61 digital multi function tester Instruction manual Contents 1 Safe

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

#9580, #9581, #9582 ACCUSTART

#9580, #9581, #9582 ACCUSTART #9580, #9581, #9582 ACCUSTART DIFFERENTIAL PRESSURE TRANSDUCER CONTROL SYSTEMS UNITROL ELECTRONICS, INC. 702 LANDWEHR ROAD NORTHBROOK, IL 60062 PHONE: 847-480-0115 FAX: 847-480-0932 info@unitrol-electronics.com

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Digital Clamp Meter DSA500A IMPORTANT: RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. Shipping damage

More information

User manual ma Loop Calibrator Jofra macal

User manual ma Loop Calibrator Jofra macal User manual ma Loop Calibrator Jofra macal User Manual macal ma loop Calibrator Copyright 2005 AMETEK DENMARK A/S LIST OF CONTENTS 1. INTRODUCTION 1.1 PACKING LIST... 2 2. SAFETY INSTRUCTIONS... 2 3.

More information

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710 An ISO 9001:2008 Company THERMOCOUPLE CALIBRATOR Mode KM-CAL-710 Thermocouple Process Calibrator is a exactitude measurement and source handhold instrument, it can be use to calibrate the Thermocouple

More information

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international

More information

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL 1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 1 1200+ WITH LVD V1.00 OWNERS MANUAL CONTENTS General Information... 2 Operating Environment... 5 Features... 6 Installation Instructions... 7 Inverter Ground

More information

PAPER 2 THEORY QUESTIONS

PAPER 2 THEORY QUESTIONS PAPER 2 THEORY QUESTIONS 1 A plastic rod is rubbed with a cloth and becomes negatively charged. (a) Explain how the rod becomes negatively charged when rubbed with a cloth... [2] (b) An uncharged metal-coated

More information

SafetyPAT Plus A B P/N:

SafetyPAT Plus A B P/N: SafetyPAT Plus A B C P/N:110401103864 Test Instrument Solutions SafetyPat Plus Instructions A.Features SafetyPat Plus The SafetyPat Plus is a handheld battery powered unit suitable for carrying out electrical

More information

INSTRUCTION MANUAL 2885 Country Dr. #190 St. Paul, MN

INSTRUCTION MANUAL 2885 Country Dr. #190 St. Paul, MN INSTRUCTION MANUAL 2885 Country Dr. #190 St. Paul, MN 55117 800-348-1316 www.leaktools.com Your Partner in Swimming Pool Water Conservation 2 Principle of the LeakTrac 2100: When an electrical charge is

More information

Holiday Detector. Model EPT/AC-30 High Voltage Coating Test Instrument Brief Description

Holiday Detector. Model EPT/AC-30 High Voltage Coating Test Instrument Brief Description Holiday Detector Model EPT/AC-30 High Voltage Coating Test Instrument Brief Description Electronic Pipeline Technology 26 Palomino Drive, Richmond Hill, Ontario, Canada, L4C 0P8 Tel: (905) 918-0025 Fax:

More information

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK. GB60/70-9 Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter Model ESR60/ESR70 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2004/2016 In

More information

OPERATING MANUAL EARTH RESISTANCE METER MRU-20

OPERATING MANUAL EARTH RESISTANCE METER MRU-20 OPERATING MANUAL EARTH RESISTANCE METER MRU-20 SONEL SA ul. Wokulskiego 11 58-100 Świdnica Version 3.0 18/06/2014 The MRU-20 meter is a modern, easy and safe measuring device. Please acquaint yourself

More information

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at USER MANUAL 10KV Digital High Voltage Insulation Tester Model MG500 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model MG500.

More information

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514 JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 PART NO: 6240040, 6240035 & 6240045 OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE Jumpstart. Before attempting

More information

ATD WATT INVERTER

ATD WATT INVERTER ATD-5954 1500 WATT INVERTER Welcome. This ATD product has been carefully engineered and manufactured to give you dependable operation. Please read this manual thoroughly before operating your new ATD product,

More information

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings

More information

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option HT-10000 Dielectric Withstand Tester 0-10000 Volts AC Output 25mA Leakage Option Instruction Manual COMPLIANCE WESTUSA Dear Customer: Congratulations! Compliance West USA is proud to present you with your

More information

Harris IRT Enterprises Digital Resistance Tester Model XP

Harris IRT Enterprises Digital Resistance Tester Model XP Harris IRT Enterprises Digital Resistance Tester Model 5012-06XP Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options

More information

Digital Low Resistance Ohm Meter

Digital Low Resistance Ohm Meter BST-MGR01 Digital Low Resistance Ohm Meter INSTRUCTION MANUAL Index 1. Safety Rules... 2. Safety Check... 3. General Description... 4. Operating Instructions... 5. Display... 6. Specifications... 11-12

More information

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL Martindale Electric Company LTD Metrohm House Penfold Trading Estate Imperial Way Watford Herts WD24 4YY T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk

More information

Operating Manual. Dry Block Temperature Calibrator PYROS-650

Operating Manual. Dry Block Temperature Calibrator PYROS-650 DRUCK & TEMPERATUR Leitenberger GmbH: Manual PYROS-650 Page 1 of 24 Operating Manual Dry Block Temperature Calibrator PYROS-650 DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. 33 72138 Kirchentellinsfurt

More information

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale: Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse

More information

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER KEW6201A CONTENTS 1. Safe testing 1 2. Procedure of removing cover. 3 2.1 Method of removing the cover. 3 2.2 Method of storing the cover. 3 3. Product summary

More information

ATD WATT INVERTER

ATD WATT INVERTER ATD-5955 2000 WATT INVERTER Welcome. This ATD product has been carefully engineered and manufactured to give you dependable operation. Please read this manual thoroughly before operating your new ATD product,

More information

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 3 NOVEMBER 2009 (12041033) 24 November (X-Paper) 09:00 12:00 This question paper consists of 6 pages. (12041033) -2- NC720(E)(N24)V

More information

ABT5020 P8 Inspectors Gauge

ABT5020 P8 Inspectors Gauge ABT5020 P8 Inspectors Gauge Instruction Manual 1.0 Index 1.0 Index 2.0 Overview 3.0 Specification 4.0 Getting Started 4.1 Measuring Flangeway 4.2 Measuring Check Gauge 4.3 Measuring Track Gauge 4.4 Measuring

More information

Dawson DDM190D. Digital Multimeter User s Manual

Dawson DDM190D. Digital Multimeter User s Manual Dawson DDM190D Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION...

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

UP120AC INSTRUCTION MANUAL

UP120AC INSTRUCTION MANUAL UP0AC INSTRUCTION MANUAL x0w A TABLE OF CONTENTS Introduction... Special Features... 4 Warning and Safety Notes... 6 Lithium Battery Connection Diagram... 0 Operation Diagram - Homepage... Operation Diagram

More information

Frequently Asked Questions

Frequently Asked Questions Why is rust protection necessary on new cars? Why is electronic corrosion protection better than chemical rustproofing? Will the PTS Rust Module System work with chemical rustproofing? Does the PTS Rust

More information

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced) Atlas ESR Capacitance and Equivalent Series Resistance Meter Model ESR60 (Enhanced) User Guide Peak Electronic Design Limited 2004/2008 In the interests of development, information in this guide is subject

More information

Thermistor Thermometer MODEL NO

Thermistor Thermometer MODEL NO Digi -Sense Thermistor Thermometer MODEL NO. 60010-70 Digi -Sense CERTIFICATE OF CONFORMANCE This thermometer was calibrated using equipment traceable to the National Institute of Standards and Technology

More information

1.Safe testing IMPORTANT:

1.Safe testing IMPORTANT: Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.

More information

INTRODUCTION. Specifications. Operating voltage range:

INTRODUCTION. Specifications. Operating voltage range: INTRODUCTION INTRODUCTION Thank you for purchasing the EcoPower Electron 65 AC Charger. This product is a fast charger with a high performance microprocessor and specialized operating software. Please

More information