1 Hand operated drives and accessories for outdoor switching devices 1

2 Outdoor hand operated drives Outdoor hand operated drives are used for manual control of outdoor switching devices, specially the medium voltage disconnectors and switch-disconnectors. Drive of L type This drive is intended for the operation of switching devices arranged in a simple way on wooden, concrete or steel poles. Attachment to wooden and concrete poles occurs by using brackets or sleeves, or fixing bands. Fixing of the drives to the steel poles occurs directly by using bolts. Using a padlock, which does not constitute a part of the delivery, can prevent tampering with the loaddisconnector by non-authorized personnel. The drive lever is linked with a short pipe draw bar of circular cross-section that serves as a connecting link to connect another set of drawbars. The movable part of the drive is connected to the drive base frame by using a stranded copper earthing bar. Box type drive This drive is supplied in the following design: single, double or triple design. The drive mechanism is installed in a box, which can be locked. The drive stroke can be adjusted ac-cording to the dimensional arrangement of the system, to a height of either 140 mm or 110 mm. Non-authorized manipulation to the system is prevented by the installation of a padlock which does not constitute a part of the delivery. Box type drives are attached in a similar way to the pole as the L-drives, with one exception, which applies to the drives of triple design. These drives must use another type of bracket. Box type drive of single design is intended to be used for switching devices without earthing switch. Drives designed as double/triple drives provide for the operation of a switching device equipped with one/two earthing switches, respectively. Drives of double and triple design are equipped with mechanical interlocking of the operating levers, which is one of the means to eliminate a faulty handling. Special design There are two options of a drive in special de-sign: box type drive equipped with a lock, with cylindrical lock insert installed from the side box type drive equipped with a lock, with cylindrical lock insert installed from the front In both the above cases the lock cylindrical insert is protected against the ingress of rainwater by using protective cover. Surface treatment All the steel parts are hot galvanized. 2

3 Arrangement of the drive components on a wooden pole Figure Drive of L type 5 - R110 Sleeve 9 - Insulator 11 - Drive bracket 12 - Smooth pipe 1.6 m (length) (with barrel type bushing) Figure Box type drive 3a - Box type drive of double design 5 - R110 Sleeve 7a - Intermediate bearing of double design 2) 9 - Insulator 10 - Drive bracket 11 - Pipe with one thread 12 - Smooth pipe 1.6 m 1) The upper intermediate bearing must be provided with a Clamping stub head in form of a joint. A barrel sleeve in the suspension lug provides for the tilting of the last draw bar to both sides from the pole axis by about 8. Figure 1 Figure 2 Length of the complete set of draw bars Recommended number of intermediate bearings up to 7m 2 up to 9m 3 3

4 Arrangement of the drive components on a concrete pole Figure Drive of L type 6 - Sleeve - size according to the pole diameter 10 - Drive bracket 11 - Pipe with one thread Figure Box type drive, single design 4a - Box type drive, double design 4b - Box type drive, triple design 6 - Sleeve - size according to the pole diameter 7a - Intermediate bearing of double 7b - Intermediate bearing of triple 9 - Insulator 10 - Drive bracket 13 - Pipe with one thread 1) The upper intermediate bearing must be provided with a Clamping stub head in form of a joint. A barrel sleeve in the suspension lug provides for the tilting of the last draw bar to both sides from the pole axis by about 8. Figure 3 Figure 4 Length of the complete set of draw bars Recommended number of intermediate bearings up to 9m 2 up to 13m 3 up to 15m 4 4

5 Arrangement of the drive components on a concrete pole Figure 5 - Drive with one reversing intermediate bearing 4 - Drive of L or box type (single design) 4a - Drive o box type (double design) 6 - Sleeve - size according to the pole diameter design 7a - Intermediate bearing of double design 10 - Drive bracket 13 - Pipe with one thread 17 - Reversing intermediate bearing, lateral, single design 17a - Reversing intermediate bearing, lateral, double design Figure 6 - Drive with two reversing intermediate bearings 4 - Box type drive, single design 4a - Box type drive, double design 6 - Sleeve - size according to the pole diameter design 7a - Intermediate bearing of double design 8 - Reversing intermediate bearing, straight type 8a - Reversing intermediate bearing, straight type, double design 10 - Drive bracket 13 - Pipe with one thread Note: Drives designed with two reversing intermediate bearings are used for poles with a height of more than 16 m. The installed reversing intermediate bearings provide for a mutual balancing of the weight of the set of drawbars. Figure 5 Figure 6 Length of the complete set of draw bars Recommended number of intermediate bearings up to 9m up to 13m up to 15m

6 Drive of L type socket pipe ,4 Function of the box type drive operating lever disconnector ON 1 - A latch, which secures the drive lever in ON switching position. After lifting the latch the drive can be moved in or out 2 - Securing pin, which also can be used as a draw bar hinge. By changing the position of pin in the lever the drive stroke can be changed from 110mm to 140mm, and vice versa 3 - Arrestment pins of the blocking mechanism 4 - Shifting rocker arm of the blocking mechanism. If both the levers find themselves in OFF position, then shifting one of the sides provides for the de-blocking of one of the levers 5 - Pins of the drive levers operating lever earthing switch OFF The function of a drive designed as double or triple drive is very similar. With the double drive the right hand lever is used for the operation of the switching device, the left hand lever for the operation of the earthing switch. With drive in triple design the control of switching device occurs through that lever which is located in medium position, while levers on both sides serve as the handling levers of earthing switches. The blocking system of multiple-type drives provides for a reliable function of switching devices equipped with earthing switches, and prevents any defective manipulation with the system. 6

7 Box type drives Single drive Double drive Triple drive Single drive Double drive Triple drive , , ,4 Intermediate bearings Single type for wooden pole Double type for wooden pole Intermediate bearing to be mounted to a wooden pole normal design joint design single ,2 double ,3 7

8 Intermediate bearing to be mounted to a concrete pole normal design joint design single ,4 double ,5 triple ,7 Reversing lateral intermediate bearing to be mounted to a concrete pole single ,2 double ,9 Reversing straight intermediate bearing to be mounted to a concrete pole 8 single ,9 double ,5

9 Clamping stub heads Clamping stub head, straight Construction d straight, flat ,5 1,0 straight, flat with link bush ,2 1,0 straight, forked ,5 1,1 angled, flat ,5 1,0 angled, flat with link bush ,2 1,0 angled, forked ,5 1,1 Angled clamping stub head ,9 Sleeves Sleeve for wooden pole ,9 Sleeve for concrete pole R H of pole , , ,5 9

10 Clamping crank l 1 l ,5 73 1, , ,6 Interposed insulator kv eff h , , ,9 Drive brackets L type, single and double box type drive bracket Pole L S wooden , concrete ,9 Triple box type drive bracket ,5 Pipes Pipe Design Standard lengths in m approx. 2,45 per m smooth 2 2,5 3 with one thread 2 2,5 3 Specifications are subject to change without notice. DRIBO 10/

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( ) DRIESCHER Outdoor Hand-Operated Actuators and Accessories Get connected http://www.driescher.com ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. (0 87 61) 6 81-0 FAX (0 87 61)

More information

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A Outdoor disconnectors FTr (previously 6 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current and 6 A 1 Outdoor disconnectors Outdoor disconnectors, produced in accordance

More information

Outdoor load disconnectors Fla 15/97 GB. three-pole design rated voltage 25 kv rated current 630 A

Outdoor load disconnectors Fla 15/97 GB. three-pole design rated voltage 25 kv rated current 630 A Outdoor load disconnectors Fla 15/97 GB three-pole design rated voltage 25 kv rated current 630 A Fla 15/97 GB outdoor load disconnectors Outdoor design, load disconnectors of Fla 15/97 GB series, with

More information

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions Operating and maintenance instructions /60 /60 for DRIESCHER Outdoor Switch-Disconnectors Type FLa /60 Type FLa /600 Type FLa /60, FLa /60 SA B76 FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

More information

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A Indoor disconnectors ITr single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current 630 6300 A Indoor disconnectors Disconnectors as shown in the data sheet are intended to be used for

More information

Summary Catalogue. In 1998, the daughter company DRIBO Stará Turá s.r.o. (Ltd.) was founded in the Slovak Republic.

Summary Catalogue. In 1998, the daughter company DRIBO Stará Turá s.r.o. (Ltd.) was founded in the Slovak Republic. Summary Catalogue The company DRIBO, spol. s r.o. (Ltd.), with its headquarters in Brno, Czech Republic, was founded in 1995, The company is involved in the manufacturing and sales of electric devices

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( )

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( ) 6410 DRIESCHER Outdoor Disconnecting Switches Fuse-Bases Earthing Switches 6410 Single- and three-pole,, current and 751 Get connected http://www.driescher.com 6 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER

More information

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A Medium voltage compact switchgears rated voltage 12 and 25 kv rated current 400 and 630 A 1 General The new air-insulated DRIESCHER medium voltage compact switchgears are ideal for application in secondary

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A Outdoor load disconnectors three-pole design rated voltage 25 and 38.5 kv rated current 630 A outdoor load disconnectors The breaking operation at the load disconnectors uses the energy of spring-based

More information

Instructions for assembly, operation and maintenance of motor operated drives VM20/30-K, and hand operated drives DK

Instructions for assembly, operation and maintenance of motor operated drives VM20/30-K, and hand operated drives DK Instructions for assembly, operation and maintenance of motor operated drives VM20/30-K, and hand operated drives DK drives for indoor switching devices for assembly on the front side of the cubicle design

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

OVERHEAD SERVICE. Items to consider

OVERHEAD SERVICE. Items to consider OVERHEAD SERVICE Items to consider The maximum length of the service wire from the ComEd pole to the point of attachment on your residence is 150 feet, if practical. Your service wire installation must

More information

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Schedules 1 to 4, Lot B: Extension of the Lessos Substation 1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/

More information

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract

More information

S&C Switch Operators Types AS-1A and AS-10

S&C Switch Operators Types AS-1A and AS-10 S&C Switch Operators Types AS-1A and AS-10 Page 1 of 11 S&C Switch Operators - Types AS-1A and AS-10 Types AS-1A and AS-10 Switch Operators are high-speed operators expressly designed for power operation

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

METAL-CLAD SWITCHGEAR TYPE SRUP 12, SRP kv A...25 ka. Manual for mounting, operation and maintenance. ABB Power Distribution

METAL-CLAD SWITCHGEAR TYPE SRUP 12, SRP kv A...25 ka. Manual for mounting, operation and maintenance. ABB Power Distribution METAL-CLAD SWITCHGEAR TYPE SRUP 12, SRP 12 12 kv...1250 A...25 ka Manual for mounting, operation and maintenance ABB Power Distribution Your safety first - always! WARNING Always observe the instruction

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2. Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.12 Product Overview ABB's type-tested ring main unit (RMU) is an SF 6 insulated RMU utilising the latest developments

More information

U STYLE "TP" TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951

U STYLE TP TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951 INSTALLATION AND MAINTENANCE j... STYLE "TP" TIME RELEASE '" INSTRUCTION PAMPHLET U--5029 AUGUST, 1951 UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. SWISSVALE, PA. 2M-B-51-2 PRINTED IN U.

More information

(K),(M),(P)489TB/G Up to 42 kv

(K),(M),(P)489TB/G Up to 42 kv IS91374-ENG - 489TB/G-45/S 22 October 2012 - Revision 1 - Supersedes edition of 4 May 2012 Page 1 of 9 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation

More information

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv N2XSEBY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,417 35 41.0 2,865 50 44.0 3,391 70 48.0 4,272 95 51.5 5,266 120 55.5 6,232

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A. ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS OVERVIEW has always been concerned with keeping a service policy for its products by means of a wide range of DRIWISA spare parts', original parts' and

More information

Design specifications

Design specifications Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor

More information

S&S POWER SWITCHGEAR EQUIPMENT LTD.,

S&S POWER SWITCHGEAR EQUIPMENT LTD., S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,

More information

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

CATALOGUE. ON Medium Voltage Outdoor Disconnectors CATALOGUE ON Medium Voltage Outdoor Disconnectors 2 O N M E D I U M V O LTA G E O U T D O O R D I S C O N N E C TO R S ON MEDIUM VOLTAGE OUTDOOR DISCONNECTORS 3 Table of conteants 004 1. Introduction 004

More information

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,

More information

NRB Disconnector for outdoor installation

NRB Disconnector for outdoor installation NRB Disconnector for outdoor installation Rated voltage: Rated current: 12 72, 5 kv 1250 2500 A Several erection alternatives Simple structure, easy to install Self cleaning contacts with magnetic locking

More information

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4

More information

N2XSERY 3 x (25-300) mm² 3.6/6 kv

N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv N2XSERY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 41.0 3,102 35 43.5 3,587 50 48.0 4,576 70 52.0 5,579 95 55.5 6,642 120 59.5 7,711

More information

Extensible Unit - VCE2a

Extensible Unit - VCE2a ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre) Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel: ELECTRICAL INDUSTRIAL COMPANY

More information

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN SF6 LOAD BREAK SWITCH Remote Controlled OCR TELE_1_2013.EN INDEX Overview IA780 MOTOR OPERATED Presentation Standards Structural Characteristics 3 3 3 Construction characteristics Components Breaking technology

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A Medium voltage switchgear type W rated voltage kv rated current 0 A General The metal-encapsulated, air-insulated medium voltage switchgears, type W are for universal application. They range from compact

More information

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves

More information

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears W 2 DRIESCHER AirInsulated MediumVoltage Switchgears Type W 2 0 Type W 2 2 Type W 2 02 Rated voltage 2 kv Rated current up to 0 A 80 W 2 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D8 MOOSBURG

More information

Attention is drawn to the following places, which may be of interest for search:

Attention is drawn to the following places, which may be of interest for search: F01B MACHINES OR ENGINES, IN GENERAL OR OF POSITIVE-DISPLACEMENT TYPE, e.g. STEAM ENGINES (of rotary-piston or oscillating-piston type F01C; of non-positive-displacement type F01D; internal-combustion

More information

LIFT TRUCK SPECIFICATIONS

LIFT TRUCK SPECIFICATIONS LIFT TRUCK SPECIFICATIONS RT50 2-Wheel Drive 4-Wheel Drive RT60 2-Wheel Drive 4-Wheel Drive RT80 2-Wheel Drive 4-Wheel Drive TABLE OF CONTENTS RT50 / RT60 / RT80 2-WD / 4WD Specifications / Dimensions.

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

SK2100. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed.

SK2100. This valve operates the gates and is equipped with a manual over ride. This valve is normally closed. SK2100 Air Parts No: 3100097 Air Tank (Medium) Over rear suspension Part No: 3100096 Air Tank (Small) Over rear suspension Part No: 3100231 5 Port 4 Way Gate Valve Rear drivers side This valve operates

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH 788 Instructions for Installation, Operation and Maintenance for DRIESCHER - Air - Insulated Medium - Voltage Compact Switchgears for Substations Rated voltage 12 kv and 24 kv Rated current 630 A 24 k

More information

GROB 4V-24 Parts. GrobBandSaw.com

GROB 4V-24 Parts. GrobBandSaw.com GROB 4V- Parts GrobBandSaw.com 888-550-3116 18 19 20 21 22 5/16-18x1/2 Hex Head Cap Screw ( 14 ) 34 35 36 37 38 39 40 39 41 42 43 44 45 46 17 16 3/8-16x3/4 Hex Head Cap Screw ( 2 ) 31 30 15 5/16-18x1 Hex

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2015 Cross-kinked roof prevents standing moisture Metering Transformer compartment label is visible with doors closed Heavy duty 11-gauge steel enclosure is all-welded construction for long

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

320A Single Phase URD Meter Loop Installations

320A Single Phase URD Meter Loop Installations 320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

GDS. Pole Mounted Disconnectors Up to 52kV

GDS. Pole Mounted Disconnectors Up to 52kV GDS Pole Mounted Disconnectors Up to 52kV General Information The switch for every application The GDS range is a modern switch system with components for different isolation and switching applications

More information

Power Heads. Standard Unload. Power Sweep. Commercial Unload. Bin Systems. Unloading

Power Heads. Standard Unload. Power Sweep. Commercial Unload. Bin Systems. Unloading Standard Unload Power Sweep Commercial Unload Power Heads Unloading Bin Systems Klean Sweep the finishing touch. The unique back-up shield and torque tube combination adjusts for close floor clearance

More information

M20 REPLACEMENT PARTS GUIDE

M20 REPLACEMENT PARTS GUIDE www.reechcraft.com/powerlift M20 GUIDE TABLE OF CONTENTS REVISION LOG Original issue of Guide...May 30, 202 TABLE OF CONTENTS - INFORMATIONAL CONTACT... 2 REVISION LOG... 2 - -... 3. POWERLIFT PARTS OVERVIEW...

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV * PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE PROCEEDING * INDOOR OUTDOOR Download free QR code scanning software

More information

Remanufactured Transmissions, Spare Parts, and Kits Catalog

Remanufactured Transmissions, Spare Parts, and Kits Catalog S6-650 Spare Parts - Gearbox Housing Group 01.010 1319 301 025 Main Housing without Check Valve 005/006/045/046/049/050 1319 301 093 Main Housing without Check Valve 083/085/084/086 1319 301 084 Main Housing

More information

No. of Single leaf Sector Gates 2 Clear span of opening 7.0m Cylinder rebate size. Sill level inner gate Gate crest level - inner.

No. of Single leaf Sector Gates 2 Clear span of opening 7.0m Cylinder rebate size. Sill level inner gate Gate crest level - inner. YARINGA MARINA SINGLE LEAF SECTOR GATES 1.1 Leading Particulars No. of Single leaf Sector Gates 2 Clear span of opening 7.0m Cylinder rebate size To suit Sector gate depth above sill - 6.5m outer Sill

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

TYPE BLT DISCONNECT SWITCHES

TYPE BLT DISCONNECT SWITCHES TYPE BLT DISCONNECT SWITCHES OUTDOOR-HOOK OPERATED 8.3KV through 38KV A & A Current Furnished with hooks for loadbreak tool REA/RUS approved S M C O 1 BLT PARALLEL BLADE DISTRIBUTION CLASS DISCONNECT SWITCH

More information

Meter Installation. -and- Padmount Transformer Guide

Meter Installation. -and- Padmount Transformer Guide Meter Installation -and- Padmount Transformer Guide Feb. 2016 METERING REQUIREMENTS The following information shall be used as a guide for installing metering equipment. A self-contained meter has all

More information

2005 BMW 545i. Crank engine at central bolt in direction of rotation until drive belt is fully guided in belt pulley.

2005 BMW 545i. Crank engine at central bolt in direction of rotation until drive belt is fully guided in belt pulley. Fig. 235: Installing Special Tool On Drive Belt Crank engine at central bolt in direction of rotation until drive belt is fully guided in belt pulley. Remove special tool 64 1 040. Installation: Check

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A Operation and Maintenance Manual AVX AVX AVX-1200 2000-15 362KV-E R00 1 TABLE OF CONTENTS 1 General Description...4 1.1 General...4 1.2 Contacts...5 1.3 Switch Base...5 1.4 Insulator Stack Bearing Assemblies...5

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

MOTOR DRIVE UNIT MA General Technical Data Design Control Circuit Assembly... 7

MOTOR DRIVE UNIT MA General Technical Data Design Control Circuit Assembly... 7 MOTOR DRIVE UNIT MA 2 Contents Page 1. General... 3 2. Technical Data... 3 3. Design... 4 4. Control Circuit... 7 5. Assembly... 7 6. Putting in to operation... 9 7. Maintenance... 9 8. Special Designs...

More information

TECHNOLOGY REVIEW. NPS Modular outdoor switch-disconnectors

TECHNOLOGY REVIEW. NPS Modular outdoor switch-disconnectors TECHNOLOGY REVIEW NPS Modular outdoor switch-disconnectors 3 Index 004 Introduction 005 018 Technology review 005 NPS technology 010 Benefits 011 Examples of pole installation 017 Basic installation guidance

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

HVX Vacuum circuit-breaker kv ( 2500 A, 40 ka)

HVX Vacuum circuit-breaker kv ( 2500 A, 40 ka) MEDIUM VOLTAGE SWITCHING DEVICE HVX Vacuum circuit-breaker 12-24 kv ( 2500 A, 40 ka) Installation Operation Maintenance 0 HVX No. AGS 531 301-01 Edition 07/07 Technical instruction AREVA T&D AREVA T&D

More information

séííéê=dãäe h~äéäîéêäéöéíéåüåáâ PQO `~ÄäÉ=Çêìã íê~åëéçêí= ÇÉîáÅÉë

séííéê=dãäe h~äéäîéêäéöéíéåüåáâ PQO `~ÄäÉ=Çêìã íê~åëéçêí= ÇÉîáÅÉë séííéê=dãäe h~äéäîéêäéöéíéåüåáâ PQO `~ÄäÉ=Çêìã íê~åëéçêí= ÇÉîáÅÉë _ Cable drum trailers 1.0-2.7 t with accessory Cable drum trailers hydr. loading 4.5-6.0 t, 80 km/h Cable drum trailers hydr. loading 5.8-7.3

More information

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1.

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1. Energy Australia Chamber Substation indoor switchgear installation,operation and maintenance instructions version 1.6 / February 2009 1 Details of revision Version Comment Date 1.0 First Draft Issue May

More information

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH 773 DRIESCHER Medium voltageswitchgear and substation accessories 773 773 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D853 MOOSBURG TEL. +49 87 80 FAX +49 87 8 2 30 http://www.driescher.com infoservice@driescher.de

More information

Copper Vertical Break Switch kv A.

Copper Vertical Break Switch kv A. Bulletin DB-106C05 Type V2-C Copper Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-C APPLICATION The Cleaveland/Price V2-C is a three pole, group operated, copper vertical break

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

31-SDMS-01 REV. 03 SPECIFICATIONS FOR 31-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PANEL This specification is property of SEC and subject to change or modification without any notice CONTENTS Clauses: Page No. 1.0 SCOPE

More information

MAIN PRICE LIST. - B 487 Perforated Strip 2 1/2" B 488 Perforated Strip 3 1/2" B 482 Perforated Strip 4 1/2" 9 1.

MAIN PRICE LIST. - B 487 Perforated Strip 2 1/2 B 488 Perforated Strip 3 1/2 B 482 Perforated Strip 4 1/2 9 1. PERFORATED STRIPS LENGTH HOLES GBP 1 Perforated Strip 12 1/2" 25 1.63 1 a Perforated Strip 9 1/2" 19 1.51 1 b Perforated Strip 7 1/2" 15 1.39 2 Perforated Strip 5 1/2" 11 0.90 2 a Perforated Strip 4 1/2"

More information

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples. Transportation and storage.. 3 General. 3 Unpacking at installation site....... 3 Transfer of cubicles at installation site... 3 Weight.. 4 Temporary storage. 4 Erection at site 5 General. 5 The switchgear

More information

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor 35-kV Safefront 2 Amp SuperWell 5-33 Page 1 216 EPM-PMS-35-311P-R2/ESW Three Phase Two Ways per Phase 2 Amp 35 kv Class Eaton's CPS LRTPs NEMA Standard Outdoor Instrument Transformer Provisions 21.1/36.6

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive Vacuum Circuit-Breakers, Type HVX 12 24 kv, of cassette design, cassette with motor drive Operating Instructions No. 531 321, Edition 09/00 Table of Contents 1 General 4 1.1 Operating Conditions 4 2 Design,

More information

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance Table of contents 02 03 04 05 06 07 08 Disconnectors from ABB Maximum reliability and minimal maintenance Technical

More information

Aluminum Vertical Break Switch kv A.

Aluminum Vertical Break Switch kv A. Bulletin DB-C106AA05 Type V2-CA Aluminum Vertical Break Switch 7.2-69 kv 600-2000 A. Designed for Simplicity V2-CA APPLICATION The Cleaveland/Price V2-CA is a three pole, group operated, aluminum vertical

More information

OPERATOR S MANUAL EPT-55 HAND PALLET TRUCK WARNING

OPERATOR S MANUAL EPT-55 HAND PALLET TRUCK WARNING OPERATOR S MANUAL EPT-55 HAND PALLET TRUCK ACTUAL PRODUCT MAY NOT APPEAR EXACTLY AS SHOWN WARNING Do not operate or service this product unless you have read and fully understand the entire contents of

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Back Drive Equipment List For Full Depth and UIC Rail fitted with Clamplocks or Machines For information only. Not for installation, commissioning,

Back Drive Equipment List For Full Depth and UIC Rail fitted with Clamplocks or Machines For information only. Not for installation, commissioning, Back Drive Equipment List For Full Depth and UIC Rail fitted with Clamplocks or Machines For information only. Not for installation, commissioning, testing or maintenance purposes. Always consult NR official

More information

STEERING SYSTEM Introduction

STEERING SYSTEM Introduction STEERING SYSTEM Introduction The steering makes it possible to change direction. The steering must be reliable and safe; there must not be too much play in the steering. It must be possible to steer accurately.

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

CATALOGUE. MANUAL DRIVE for indoor MV switching devices TYP RPP XA 40

CATALOGUE. MANUAL DRIVE for indoor MV switching devices TYP RPP XA 40 CATALOGUE MANUAL DRIVE for indoor MV switching devices Unsere Handelsvertretung in Deutschland TYP RPP XA 40 ISO 9001:2009 ISO 14001:2005 GENERAL INFORMATION The RPP... drive mechanism is a device used

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application s SICOP Bimetal Overload Relays Type 3UA5/6 & 3UC5/6 Introduction The bimetal overload relays type 3UA5/6 & 3UC5/6 relays are indigenously manufactured and bring to the users a whole range of benefits,

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Crane Systems & Rigid Lifting Guides

Crane Systems & Rigid Lifting Guides Crane Systems & Rigid Lifting Guides To go with the vacuum and tube lifters FEZER offers you as well suitable crane systems and guarantees a perfectly adjusted complete system from one source only. For

More information