1 Operating & Maintenance Manual s are utilised to remove contaminant from hydraulic systems. Long working life of the hydraulic components and correct use of the hydraulic systems can be assured only when maintenance is performed correctly and at regular intervals. It is essential to use indicators that serve to inform the user of the need to change the cartridge. ffective contamination control can be assured only by the correct use of clogging indicator. 0
2 INSTLLTION heck that the pressure value of the selected filter is higher than the system s maximum operating pressure (the maximum pressure value is shown on the dataplate). heck that the filter body contains the filter cartridge. heck that the operating fluid is compatible with the material of the body, cartridge, and seals. Install the filter in an accessible position for correct and troublefree maintenance and visibility. Start the machine and check for the absence of oil leaks from the filter and relative fittings. F Repeat the visual inspection when the system arrives at the operating temperature of the oil. MINTNN ll maintenance operations must be performed only by suitably trained personnel. The hydraulic system must be depressurised before performing maintenance operations. Maintenance must be carried out using suitable tools and containers to collect the fluid contained in the filter body. Spent fluids must be disposed of in compliance with statutory legislation. o not use naked flames during maintenance operations. Use the utmost caution in relation to the temperature of the fluid. High temperatures can lead to residual pressure with resulting undesirable movements of mechanical parts. HNGING TH FILTR LMNT The date on which the filter elements are changed must be entered in the machine datasheet. Spare parts installed must be in compliance with the specifications given in the machine operating and maintenance manual. bodies and tools must be thoroughly cleaned prior to each maintenance operation. fter having opened the filter to change the filter element, check the condition of the seals and renew them if necessary. lean thoroughly before reassembling. MINTNN TOOLS Type logging ifferential Indicators VR VP F V J NR KR U ody Type /F 7 0 MPF MPF 00 MPF 00 MPF 00 MPF 0 MPF 0 MPF 0 MPF MPF MPF MPF 0 MPF MPF 70 over screw Type /F 0 MPT MPT 0 MPT 07 MPT 0 MPT 0 MPT 0 MPT MPT 0 ir reather screw Type /F MPH MPH 0 MPH 0 MPH MPH 0 MPH 0 MPH 0 MPH 0 MPH 0 over screw Type /F 7 ir reather screw Type /F Spring retainer nut Type /F 7 MPI MPI 00 MPI 0 MPI 0 MPI 0 Spring retainer nut Type /F 7 FRI FRI 0 FRI 00 FRI 00 FRI 0 FRI over screw Type /F RF RF 0 RF 0 Knob nut Type /F 0 FRI 0 FRI 0 0
3 HNGING TH FILTR LMNT IN MPF FILTRS epressurise the system and clean the filter. Unscrew the screws remove out the cover. Using the new filter element, lubrificate seal with the operating fluid. Put the filter element into the bowl. Fig. Fig. heck the condition of the bowl seal (see Fig. ): Take out the filter element and bowl using the handle on the filter element. Fig. Fig. Remove the filter element from the bowl. ollect the spent oil and cartridge in a suitable container and dispose of them in compliance with statutory legislation. 7 heck the condition of the cover seal (see Fig. ): Screw the crews of the cover. Fig. Fig. Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature. 0
4 HNGING TH FILTR LMNT IN MPT FILTRS epressurise the system and clean the filter. Unscrew the cover. Using the new filter element, lubrificate seal with the operating fluid. Put the filter element into the bowl. Fig. Fig. heck the condition of the bowl seal (see Fig. ): Take out the filter element and bowl using the handle on the filter element. Fig. Fig. Remove the filter element from the bowl. ollect the spent oil and cartridge in a suitable container and dispose of them in compliance with statutory legislation. 7 heck the condition of the cover seal (see Fig. ): Screw the cover. Fig. Fig. Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature. 0
5 HNGING TH FILTR LMNT IN MPH MPI FILTRS epressurise the system and clean the filter. Fig. MPH 0 0 MPH 0 Unscrew the cover. Fig. MPH 0 0 Unscrew the nuts from the pin but do not remove. Push the cover ==> turn on the right ==> take out the cover Fig. MPH 0 Unscrew the screws and remove the cover. Fig. MPH 0 Unscrew the screws and remove the cover. Fig. Fig. Fig. Fig. Take out insert assembly + filter element. Unscrew and remove nuts + spring from the threaded pin G. Remove the filter element from the insert assembly. ollect the spent oil and cartridge in a suitable container and dispose of them in compliance with statutory legislation. onnect the filter element to the insert assembly. Screw the nuts + spring from the threaded pin G. F G G G 0
6 a Screw the nuts + spring up to the contact with the chamfer on the threaded pin G. hamfer H of the threaded pin. G heck the condition of the stand seal : if renewing, lubricate the new seal with the Put in insert assembly and filter element. G H 7 heck the condition of the cover seal : Fig. Fig. Fig. Fig. Fig. MPH 0 0 MPH 0 Screw the cover. Fig. MPH 0 0 Push the cover ==> turn to the left ==> Screw the nuts to the pin. Fig. MPH 0 Screw the screws of the cover. Fig. MPH 0 Screw the screws of the cover. 9 Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature. FOR MINTNN FILTR MPI: See Item a 07
7 HNGING TH FILTR LMNT IN FRI FILTRS epressurise the system and clean the filter. Unscrew the screws take out the cover. Lubrificare la guarnizione inferiore dell elemento filtrante con il fluido di lavoro prima dell installazione. Fig. Fig. Remove the filter element and cover from the body of the filter. Remove the filter element from the cover/bypass valve. ollect the spent oil and cartridge in a suitable container and dispose of them in compliance with statutory legislation. heck the condition of the cover seal (see Fig. ): Screw the screws of the cover. Fig. Lubricate the filter element seal with the operating fluid. Place the filter element on the cover/bypass valve. Fig. 7 Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature. Fig. 0
8 HNGING TH FILTR LMNT IN FRI FILTRS epressurise the system and clean the filter. Unscrew the cover. Remove the cover and the filter element from the body of the filter. Lubricate the filter element seal with the operating fluid. Place the filter element on the cover/bypass valve. Fig. Lubricate bottom seal of filter element with the Fig. Remove the filter element from the cover/bypass valve. ollect the spent oil and cartridge in a suitable container and dispose of them in compliance with statutory legislation. Fig. 7 heck the condition of the cover seal (see Fig. ): Fig. Screw the cover. Remove the contamination retainer binder from the filter element and clean. Place the the retainer binder on the new filter element. Fig. Fig. L L L Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature. 09
9 HNGING TH FILTR LMNT IN RF 0 0 FILTRS epressurise the system and clean the filter. Unscrew the cover. ollect the spent oil in a suitable container and dispose in compliance with statutory legislation. Remove the cover and the filter element from the body of the filter. Lubricate the filter element seals with the operating fluid. Place the filter element on the cover/bypass valve. Fixed support element and screw nut and thread spigot : hand tightening. Foot valve closed Fig. Fig. Unscrew thread spigot nut, remove spigot, nut and support filter element. Remove the filter element from the cover/bypass valve. ollect the spent filter element in a suitable container and dispose of them in compliance with statutory legislation. heck the condition of the cover seal (see Fig. ): Foot valve closed Screw the cover. Foot valve closed Fig. Foot valve open Fig. 0 Fig. Start the machine and check for the absence of leaks. Repeat the check when the machine has reached its operating temperature.
10 MINTNN IR RTHR MPT MPH 0 Unscrew the screw remove the cover and filter element. ssembling item. Unscrew air breather. Screw new air breather.
SERIES. Maximum pressure 110 bar
SERIES Maximum pressure 0 bar F l o w r a t e s t o 9 5 l / m i n Technical data FMP 09 Compatibility Filter housing (Materials) Head: nodized aluminium Housing: nodized aluminium Bypass valve: Steel Pressure
More informationSpare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar
Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN 24550 up to 630 l/min, up to 10 bar RFN 40 RFN 63 RFN 100 RFN 160 RFN 250 RFN 400 RFN 630 1. MAINTENANCE 1.1 GENERAL Please follow
More informationSpare Parts List Return Line Filter RFM with 4-hole attachment
Spare Parts List Return Line Filter with 4-hole attachment Tank-top mounted version: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. MAINTENANCE GENERAL Please follow
More informationSpare parts list Return line filter RFM with 2-hole attachment
Spare parts list Return line filter with 2-hole attachment Tank-top mounted version: up to 200 l/min, up to 10 bar 75 90 150 165 185 195 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!
More informationSpare parts list Inline filter FLND switchable
Spare parts list Inline filter switchable to DIN 24550*, up to 400 l/min, up to 63 bar *Filters and fi lter elements also available in HYDAC dimensions 60 110 140 40 63 100 160 250 400 1. MAINTENANCE 1.1
More informationSpare Parts List Filter NFD Change-Over Version
Spare Parts List Filter Change-Over Version up to 1600 l/min, up to 5 bar 1340 640 540 7840 10440 1. MAINTENANCE GENERAL Please follow the maintenance instructions! 1. INSTALLATION Before fitting the filter
More informationSpare Parts List Return line filter RF
Spare Parts List Return line filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!
More informationRFN Series Service and Parts
Filters RFN Series Service and Parts up to 166 gpm (630 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationMAINTENANCE SCHEDULES
MT L T OTT Introduction.............................. 304 Warranty................................. 304 Maintenance - Without YT Maintenance omputer..................... 305 Maintenance Intervals....................
More informationSpare Parts List Mobile Spin-On Filters MF/MFD. Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel
Spare Parts List Mobile Spin-On Filters MF/MFD Flow rates up to 300 l/min Pressure range up to 8 bar Material: Aluminium / Sheet Steel 1. MAINTENANCE INSTRUCTIONS 1.1. USER INSTRUCTIONS FOR FILTERS This
More informationOIL FILLER AND AIR BREATHER FILLER CAPS
OIL FILLER ND IR RETHER FILLER CPS The complete series of oil filter and makes it possible to meet all market demands. Metal and plastic styles suitable for use on mobile equipment are available. s perform
More informationOff-line filter system
Off-line filter system 30 NFF2, 50 NFF2, 80 NFF2 RE 51433-B/04.10 Replaces: -.- English Operating instructions The data specified above only serve to describe the product. No statements concerning a certain
More informationRKM Series Service and Parts
Filters RKM Series Service and Parts up to 211 gpm (800 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions on the last page. 1.2 Installation Before installing
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More information525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters
Stainless steel high pressure fi lters FZP series Maximum pressure up to 0 bar 55 Stainless steel high pressure filters FILTER SIZING The correct filter sizing have to be based on the variable pressure
More informationFilters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal
1. Maintenance Filters Series Change-Over Return Line Filter Service and Parts up to 343 gpm (1300 l/min), up to 362 psi (420 bar) 1.1 General Please follow the maintenance instructions. 1.2 Installation
More informationReturn / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters
Return / Suction fi lters Inline LMP series Maximum pressure up to 8 bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure
More informationMICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL
MICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL Edition July 2012 Index GENERAL... 3 TECHNICAL CHARACTERISTIC... 3 MINIMUM LEVEL SENSOR... 3 ELECTROVALVE... 3 TYPES... 4 VERSION WITH BOX AND THANK 1.5LT...
More informationDIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min
Low & Medium Pressure filters & series Maximum pressure up to 60 bar Flow rate up to 0 l/min DIN 550 09 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More information2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE
Page 1 of 16 CONTENTS 1.- INTRODUCTION 2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 4.- OPERATION OF A BALL VALVE 5.- PERIODICAL INSPECTION OF THE VALVE AND
More informationRepair Manual. General Pump is a member of the Interpump Group. Ref Rev.A 09-13
Repair Manual General Pump is a member of the Interpump Group 8 INDEX 1. INTRODUCTION..................................................Page 3 2. REPAIR GUIDELINES..............................................Page
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst
More informationPressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationConnection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to
More informationA408 GB. Pneumatic oil and diesel pumps 1:1
03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationOperating Instructions for Elevator Buffers type LP
Operating Instructions for Elevator Buffers type LP 1 Scope of application The Elevator Buffer type LP is an energy dissipation type buffer according to EN 81-1/2, EN 81-20, EN 81-50 5.5 and therefore
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationReturn / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters
Return / Suction fi lters mounted MRSX series Maximum pressure up to bar Flow rate up to l/min 9 Return / Suction fi lters FILTER SIZG The correct filter sizing have to be based on the variable pressure
More informationFHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters
High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing
More informationLDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min
Low & Medium Pressure filters LDP & series Maximum working pressure up to 6 MPa (60 bar) Flow rate up to 0 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZING INDEX CALCULATION CORRECTIVE
More informationInstructions D. Important Safety Instructions For detailed sprayer information and warnings, see Operation manual. Pressure Relief Procedure
Instructions Inlet/Outlet Valve Repair Kit for Project Painter 5, Project Painter 7, X5, X7, LTS 15, LTS 17, Project Painter Plus, M3+, M5+, L10+, Pro Plus 20, Pro Plus 30, and Pro Plus 45 irless Sprayers
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request)
HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to
More informationRFL Cast Series Service and Parts
Filters RFL Cast Series Service and Parts up to 343 gpm (1300 l/min), up to 580 psi (40 bar) 1. Maintenance 1.5 Torque Values 2. Element Replacement 1.1 General Please follow the maintenance instructions.
More informationLMP series
Low & Medium Pressure fi lters LMP 95-95-95 series Maximum working pressure up to.5 MPa (5 bar) - Flow rate up to 000 l/min 7 Low & Medium Pressure filters Introduction FILTER SIZG DEX CALCULATION CORRECTIVE
More informationPreventive maintenance 4
00 Series Preventive maintenance Preventive maintenance periods Use the procedures in this chapter to maintain your engine in accordance with the preventive maintenance schedule. Check the periods given
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationINSTALLATION AND USER INSTRUCTIONS
Ultraviolet Sterilizers INSTALLATION AND USER INSTRUCTIONS Document applicable to all models 1000 & 1000 eco 2000 & TIO-UV & 2000 eco TIO-UV-eco 10000 1 UV CINTROPUR: Applications p.2 2 Design p.2 3 Installation
More informationPNEUMATIC PUMP Series
PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS
More informationZ1 Free Ride INSTRUCTIONS GENERAL RULES
INSTRUCTIONS GENERAL RULES 1. Where specified, assemble and disassemble the shock absorption system using the MARZOCCHI special tools only, as shown in the table below. 2. On reassembling the suspension
More informationOWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.
OWNER'S MANUAL READ BEFORE USE! Model No.: BH5003-3 Style No.: 66646 For Outdoor Use Only! Use Propane Gas Only! Propane cylinders sold separately. USE PROPANE GAS ONLY! -Do not store or use gasoline or
More informationPressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )
HYDRULIC FILTRTION F16-XD series In line medium pressure filters Technical Information Pressure: Max working 16 bar (3 psi) (acc. to NFP T 3.1..1) Burst 48 bar (69 psi) (acc. to NFP T 3.1..1) Housing Connection
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRULIC FILTRTION In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x: 3 bar (4 psi)
More informationDYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL
DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL LILLY ENGINEERING COMPANY 217 CATALPA STREET P.O. BOX 173 ITASCA, ILLINOIS 60143 630-773-2222 FAX: 630-773-3443 www.lillyengineering.com
More informationLMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min
Low & Medium Pressure fi lters LMP - series Maximum pressure up to 8 bar - Flow rate up to l/min 5 Low & Medium Pressure filters FILTER SIZING The correct filter sizing have to be based on the variable
More informationMANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI
Form No. 102963 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.hytec.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)
More informationRO RC-PC DE EN. Montage- und Betriebsanleitung Installation and operation instructions. Member of JOST-World
Montage- und etriebsanleitung Installation and operation instructions E EN ufrüstsatz pneumatische Fernbedienung Upgrade kit Remote ontrol - Pneumatic omfort RO R-P ROE71461 ROë400T1/ROë430T2 ROE71459
More informationSuper T QR20 INSTRUCTIONS GENERAL RULES
INSTRUCTIONS GENERAL RULES 1. Where specified, assemble and disassemble the shock absorption system using the MARZOCCHI special tools only. 2. On reassembling the suspension system, always use new seals.
More informationOperating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content
1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationFilters. HF2P 79.4 Series Service and Parts. Index P Clogging. Indicator Port G 1/
2.05 52 3.39 86 0.24 6 0.84 21.4 P Clogging Filters Indicator Port G 1/2 4.02 102 3.13 HF2P 79.4 Series Service and Parts INLET OUTLET This symbol is followed 3.86 by user tips and particularly useful
More informationTechnical Information
Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Series "SR" Steam Filters USFDA, USDA, and 3A Compliance Balston SR Steam Filters
More informationSwaging Machine Type H32B4
USER MANUAL Swaging Machine Type H32B4 CONTENTS WARRANTY CONDITIONS...3 EC DECLARATION OF CONFORMITY...4 SAFETY REGULATIONS...5 TECHNICAL / DIMENSIONAL DATA...6 HANDLING/TRANSPORT...6 PRELIMINARY CHECKS...6
More informationZ3 QR20 (110) GENERAL
(11) 175 18 8 Ø3 +.5 L.MAX=491 L.L.=481 ±2 L.MIN=371 426 55 ±2 TRAVEL 11 Ø3 15 2 -.1 +1 248.5 GENERAL The fork is sprung by a mechanical coil system and uses hydraulic rebound damping. Spring pre-load
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationRETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass
COMPONENTS RB MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2) Max working: 0 kpa
More informationSeries T2000 Wall Mounted Emergency Eye & Eye/Face Wash
Series T2000 Wall Mounted Emergency Eye & Eye/Face Wash In order to comply with the NSI Z358.1 Standard the following notes should be followed: Station should be assembled and installed in accordance with
More informationFlow control valve type SJ
Flow control valve type SJ Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 315 bar 15 lpm D 7395 11-2013-1.1 by HAWE Hydraulik SE. The forwarding and reproduction of this
More informationPOWER PACK W/OIL COOLER P/N 32800
POWER PACK W/OIL COOLER P/N 32800 OPERATION AND MAINTENANCE MANUAL Copyright 2017 by All rights reserved. No part of this publication may be copied, reproduced or transmitted in any form whatsoever without
More informationFlow rates to 3000 l/min
MPH Maximum pressure bar Flow rates to l/min echnical data housing (Materials) Head: luminium: MPH nodised luminium: MPH 68 Painted luminium: MPH 66 Cover: Nylon: MPH luminium: MPH nodised luminium: MPH
More informationIn line high pressure filters. HF 725 series
In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.
More informationFilters. HF3P Series Places 60 b c x d DP 4 Places Flange
1/2"-20UNF x 17 2.36 4 Places 60 b 6.42 163 5.23 133 4.53 115 c x d DP 4 Places a 6.30 Filters 160 6.42 163 Flange 2.05 0.24 52 6 P Clogging HF3P Series Indicator Port G 1/2" Service and Parts 6.30 160
More informationModel VR4 Vacuum Regulator
Model VR4 Vacuum Regulator Installation, Operation & Maintenance General: The Archer Instruments Model VR4 vacuum regulator is designed for use in vacuum gas feed systems. The VR4 incorporates an integral
More informationZ3 Air (80) GENERAL. BAM: Bomber Aerospace Material. Special alloy developed from aerospace material. Ø TRAVEL 80 L.MAX=461 L.L.=451 L.
(80) 175 18 80 Ø30 +0.05 0 55 L.MAX=461 L.L.=451 L.MIN=371 396 ±0,1 TRAVEL 80 ±2 Ø30 15 20 0-0.1 +1 0 248 GENERAL Special air/oil damped cross-country fork: each leg uses pressurized air blown through
More informationFilters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information
142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model
More informationASSEMBLY AND INSTRUCTIONS FRANKE MINERVA 3-IN-1 KETTLE TAP WATER FILTER HOUSING KIT
ASSEMBLY AND INSTRUCTIONS FRANKE MINERVA 3-IN-1 KETTLE TAP WATER FILTER HOUSING KIT Retain for reference NB: For use only with Franke Minerva Kettle Tap Introduction Before you begin Before attempting
More informationZ1 Free Ride (110) GENERAL
GENERAL (110) 175 80 Ø 30 +0.05 0 L.MAX=493 L.L.=483 ±2 L.MIN=373 426 ±2 57 CORSA 110 TRAVEL 110 18 Ø 30 15 20 0-0.1 +1 0 248.5 Special ride and Downhill fork whose legs are damped by a spiral springs
More informationPro Gun (Model: UCpro and UCPro Plus)
Undercoating/Rustproofing Pro Gun (Model: UCpro and UCPro Plus) Professional Undercoating and Rustproofing gun designed to apply protective coatings such as waterborne and solvent based under coatings,
More information1.Safe testing IMPORTANT:
Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.
More informationZ3 Coil (80) GENERAL. BAM: Bomber Aerospace Material. Special alloy developed from aerospace material. Ø TRAVEL 80 55
(8) 175 8 Ø3 +.5 L.MAX=461 L.L.=451 L.MIN=371 ±2 396 TRAVEL 8 55 18 Ø3 15 2 -.1 +1 248.5 GENERAL The fork is sprung by a mechanical coil system and uses hydraulic rebound damping. Spring pre-load adjustment
More informationAIR FILTER/BY-PASS ASSEMBLY PACKAGE
AIR FILTER/BY-PASS ASSEMBLY PACKAGE MAINTENANCE AND OPERATING INSTRUCTIONS SUMMARY 0 Emissione Luca Passoni Marco La Rocca Marco La Rocca 15/11/01 Rev. Descrizione: Redatto: Convalidato: Approvato: Data:
More informationInspection and Maintenance of Flame Arresters
7 Inspection and Maintenance of Flame Arresters 7.1. Need and Importance of Maintenance Inadequate maintenance of flame arresters can result in their failure to perform as required. Failure can result
More informationROYAL SOLAR LAMP POST US Patent # Instruction Manual. Models: GS-98L, GS-98S GS-98D, GS-98T, GS-98W, GS-98P, GS-98F
ROYAL SOLAR LAMP POST US Patent # 7172307 Instruction Manual Models: GS-98L, GS-98S GS-98D, GS-98T, GS-98W, GS-98P, GS-98F . Please read the instruction manual carefully to obtain the best results from
More informationStarting up hydraulic systems
General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable
More informationProduct Features. Easy installation. Pump adds only 3.3 to the overall assembly height. 60 GPH (227 LPH) flow rate while in priming mode.
Primer Pump Kits RKP1912 (12 vdc) and RKP1924 (24 vdc) Instruction Part Number 14356 Rev C Primer pump kits are an innovative and proprietary system consisting of a prescreen filter, a flow by-pass circuit,
More informationPressure relief valve
Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationInstallation/Care/Use Manual
Installation/Care/Use Manual EZH20 In Wall Bottle Filling Station LZWSM8* LZWSMD* LZWSM8P* LZWSMDP* Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
More informationIn line high pressure filters. HF 735 series
In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.
More informationWinslow Lube Oil Full-Flow Type 1 Filter Service Instructions
Vent Plug (NPT) Winslow Lube Oil ull-low Type 1 ilter Service Instructions Parts List Part escription Part over ssembly and lamp Housing rain Plug ilter lement omponent Kit See Ordering Information on
More informationSERVICE INSTRUCTION PURGING OF LUBRICATION SYSTEM FOR ROTAX ENGINE TYPE 912 AND 914 (SERIES) SI SI Repeating symbols:
SERVICE INSTRUCTION PURGING OF LUBRICATION SYSTEM FOR ROTAX ENGINE TYPE 9 AND 914 (SERIES) Repeating symbols: Please, pay attention to the following symbols throughout this document emphasizing particular
More information2004 Toyota RAV ENGINE Lubrication - RAV4
2004 ENGINE Lubrication - RAV4 OIL AND FILTER INSPECTION 1. CHECK ENGINE OIL QUALITY Check the oil for deterioration, entry of water, discoloring or thinning. If the quality is visibly poor, replace the
More informationAVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES
AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES TABLE OF CONTENTS GENERAL SERIES 854(TYPICAL EXPLODED VIEW) COMPONENT LIST INTRODUCTION TO AVK/GLENFIELD SERIES
More information6 8 Magnum 40(x) Maintenance Instructions
RE INSTRUTIONS IN FULL EFORE INSTLLTION. QUESTIONS? LL 916-760-4524 M-F 8:00 M 4:30 PM PST t ackflow irect we are committed to making our products as easy to install as possible. We design for most contingencies,
More informationX-FLY (80) GENERAL. BAM: Bomber Aerospace Material. Special alloy developed from aerospace material. Ø TRAVEL Ø30
(8) 175 8 Ø3 +.5 L.MAX=461 L.L.=451 L.MIN=371 ±2 396 ±2 TRAVEL 8 55 18 Ø3 15 2 -.1 +1 248.5 GENERAL Special air/oil damped cross-country fork: each leg uses pressurized air blown through a special valve
More informationAUTOMATIC AIRSPRAY GUN
INSTRUCTION MANUAL AUTOMATIC AIRSPRAY GUN Manual : 0407 573.011.212 Date : 19/07/04 Supersede : KREMLIN REXSON - Site de Stains : 150, avenue de Stalingrad 93 245 - STAINS CEDEX - FRANCE Téléphone : 33
More information3. Installation and Commissioning 4. Maintenance 5. Spares
INSTLLTION ND MINTENNCE INSTRUCTIONS IM-P305-06 US November 2003 1/2" to 4" (DN15 to DN100) KE41, 43, 61, 63, 71 and 73 NSI Control Valves 1. Safety 2. Technical details 3. Installation and Commissioning
More informationF14MD F18MD. Modular filters, suitable for compressed air FEATURES. Filter for inlet pressure up to 30 bar (435 psi).
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 302035 info@idinsertdeal.com www.idinsertdeal.com F14MD F18MD Modular filters, suitable for compressed air FEATURES Filter for inlet pressure
More informationMANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS
CCESSORIES GENERL CTLOG IR TRETMENT, UXILIRY, VCUUM, ND FLUORORES PRODUCTS MNIFOLD REGULTORS MNIFOLD REGULTORS CONTENTS Features, Flow Rate Characteristics 115 Specifications, Port Size 116 Inner Construction,
More informationINSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS
TM INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS WARNING This Special Instruction Manual and General Instructions Manual, CA-1, should be read thoroughly prior to pump installation, operation
More informationV&P SCIENTIFIC LEVITATION STIR BALL LOADER. VP 725C-96 Operating Instructions
V&P SCIENTIFIC LEVITATION STIR BALL LOADER VP 725C-96 Operating Instructions TECHNICAL NOTE 178 9823 Pacific Heights Boulevard, Suite T, San Diego, CA 92121 (858) 455-0643 Fax: (858) 455-0703 email: sales@vp-scientific.com
More informationDuo Filter Mixer Tap Filter Installation Instructions
Duo ilter ixer Tap ilter nstallation nstructions A. over. ilter head B. ounting plate. 3/8 Tubing D. ounting screws J. 3/8 Non Return Valve. ilter cap. 3/8 Tee Adaptor. ilter body L. ½ emale Adaptor. ½
More informationPressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )
HYDRULIC FILTRTION In line high pressure filters Technical Information Pressure: Max working 420 bar (6000 psi) (acc. to NFP T 3.10.5.1) Burst 1260 bar (18300 psi) (acc. to NFP T 3.10.5.1) Housing Connection
More informationGENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability
Diaphragm interposed fluid head Use and maintenance manual Model Model BR Model UK Positive displacement metering pump PDP Series Type B I 250 I 350 SD GENERAL WARNING General instructions We thank you
More informationGENERAL PUMP A member of the Interpump Group KEZ SERIES
KEZ Repair Manual INDEX 1. INTRODUCTION..................................................Page 3 2. REPAIR ISTRUCTIONS.............................................Page 3 2.1 Crank Mechanism Repair.........................................Page
More informationMASTER CYLINDER MC9601
MASTER CYLINDER MC9601 1 CHECK...1 2 INSTALLATION...1 3 CHECK LINE POSITIONING...2 4 SET UP...2 5 BLEEDING OPERATIONS...3 6 MC013/AC004 BRAKE SWITCH...5 7 KR0091 LEVER...6 8 KR0119 BLEEDER SCREW+RUBBER...7
More informationTORQUE TRANSDUCER TMHFB-*NM (for Torque Transducer) Instruction Manual. MinebeaMitsumi Inc. Sensing Device Business Unit
TORQUE TRANSDUCER TMHFB-*NM (for Torque Transducer) Instruction Manual MinebeaMitsumi Inc. Sensing Device Business Unit Please read this manual thoroughly before attempting to use the equipment. Be sure
More informationLPF Series Service and Parts
Filters LPF Series Service and Parts up to 140 GPM(280 l/min), up to 1000PSI(50bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter
More informationINSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE
INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE Page 1 of 13 1.1 General CHAPTER 1 - GENERAL INFORMATION This manual contains maintenance instructions with pertinent
More informationHigh Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters
igh Pressure fi lters FP series Maximum pressure up to bar Flow rate up to 7 l/min igh Pressure fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending
More informationMGM Brakes Service Manual
MGM Brakes Service Manual MAGNUM Performance Plus Spring Brake Actuators (MJ-Series 3.00 / 76mm Long Stroke ) For: S-Cam Tamper-Resistant MAGNUM Performance Plus Spring Brake Actuators Figure 1 A B C Your
More information