User s Manual. PH4/OR4 Sensor Series ph and ORP Sensors IM 12B10B00-01EN IM 12B10B00-01EN. 7th Edition

Size: px
Start display at page:

Download "User s Manual. PH4/OR4 Sensor Series ph and ORP Sensors IM 12B10B00-01EN IM 12B10B00-01EN. 7th Edition"

Transcription

1 User s Manual PH4/OR4 Sensor Series ph and ORP Sensors IM 12B10B00-01EN IM 12B10B00-01EN 7th Edition

2 Introduction Thank you for purchasing the PH4/OR4 Sensor Series ph and ORP Sensors. Please read the following respective documents before installing and using the sensors. i This manual is applied to the following sensors; PH4P Polymer Electrolyte ph Sensor PH4PT Polymer Electrolyte ph Sensor with RTD OR4P Polymer Electrolyte ORP Sensor PH4F HF-Resistant ph Sensor PH4FT HF-Resistant ph Sensor with RTD PH4C ph Sensor for Chemical Process PH4CT ph Sensor for Chemical Process with RTD OR4C ORP Sensor for Chemical Process PH4FE ph Sensor for Fermentation Other relevant models are described in the following manuals. Equipment Model Model name Manual Holder PH8HS Submersion type holder IM 12B07M01-E PH8HF Flow-through type holder Adapter (Option code) (this manual) SA405 Adapter with temperature sensor Transmitter FLXA202, FLXA21 2-Wire Analyzer IM 12A01A02-01E etc. FLXA402 4-Wire Converter IM 12A01F01-02EN IM 12A01F02-01EN etc. PH450G ph/orp Converter IM 12B07C05-01E Terminal box WTB10 Terminal box IM 19D01B01-01E Distributor PH201G Distributor IM 19B01E04-02E VJA1, MA1, etc. Distributor IM 77J01A01-01E, IM 77J04A01-01E etc. Accessories PH8AX Accessories for ph meter IM 12B07W03-01E OR8AX Accessories for ORP meter IM 12C04W02-01E Check the following when you receive the product: Appearance Model Name (on nameplate of sensor) and Suffix Codes (on nameplate of packing box) If you have any questions, contact our sales representative or your local distributor. Notes on Handling User s Manuals Please hand over the user s manuals to your end users so that they can keep the user s manuals on hand for convenient reference. Please read the information thoroughly before using the product. The purpose of these user s manuals is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product. No part of the user s manuals may be transferred or reproduced without prior written consent from YOKOGAWA. YOKOGAWA reserves the right to make improvements in the user s manuals and product at any time, without notice or obligation. If you have any questions, or you find mistakes or omissions in the user s manuals, please contact our sales representative or your local distributor. Some drawings may be partially emphasized, simplified, or omitted, for the convenience of description. Media No. 12B10B00-01EN 7th Edition : Nov (YK) All Rights Reserved Copyright 2016 Yokogawa Electric Corporation

3 ii Safety Precautions Safety, Protection, and Modification of the Product In order to protect the system controlled by the product and the product itself and ensure safe operation, observe the safety precautions described in this user s manual. We assume no liability for safety if users fail to observe these instructions when operating the product. If this instrument is used in a manner not specified in this user s manual, the protection provided by this instrument may be impaired. If any protection or safety circuit is required for the system controlled by the product or for the product itself, prepare it separately. Be sure to use the spare parts approved by Yokogawa Electric Corporation (hereafter simply referred to as YOKOGAWA) when replacing parts or consumables. Modification of the product is strictly prohibited. The following words are used in this manual. CAUTION This symbol gives information essential for understanding the operations and functions. NOTE This symbol indicates information that complements the present topic. Warning and Disclaimer The product is provided on an as is basis. YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance. Compliance with the simple apparatus requirements PH4/OR4 sensor series meets the simple apparatus requirements defined in the following standards. Note1: PH4P, PH4PT, OR4P, PH4F, PH4FT, PH4C, PH4CT, OR4C, and PH4FE can be applied as simple apparatus. Note2: For PH4PT, PH4FT, and PH4CT classification of intrinsic safety, and electrical parameters are approved by TIIS, which is valid in only Japan. Use the sensors under the conditions of use required by the standards. Applicable standards: ANSI/ISA (2014) ANSI/ISA (2009) CAN/CSA-C22.2 NO :14 CAN/CSA-C22.2 NO :11 한국전자파적합성기준 GB Conditions of use: (1) Use with an internally isolated transmitter, or use with a transmitter in combination with isolated barrier. The FLXA21/202 is internally isolated. (2) Upper limit of the process temperature. The upper limit of process temperature is indicated below when the sensor is used in combination with a YOKOGAWA transmitter.

4 For FLXA21/202, model and suffix code below is available. FLXA21-D- -D- -P1- -A-N-LA-N-NN can be any value. must be EA, CD, CH, or EG must be NN or P1. Any option code is available. FLXA202-D- -D- - P1- -A-N-LA-N-NN can be any value. must be CD, CH, or CG must be NN or P1. Any option code is available. For PH202S, model and suffix code below is available. PH202S- -E must be C or U. There are no PH202S models that meet the Korean explosion proof standards. Any option code is available. Upper limit of process temperature (Ambient temperature : -20 C to +40 C) Transmitter used in combination FLXA21/202 PH202S Sensor type PH4P PH4C PH4F Temp. class OR4P OR4C PH4FE* PH4P PH4C PH4F OR4P OR4C PH4FE * T T T T T T *: Do not use beyond upper limit of process temperature at sterilization. Transmitter used in combination FLXA21/202 PH202S Sensor type Temp. class PH4PT PH4FT PH4CT PH4PT PH4FT PH4CT T6 NA* NA* NA* T T T T T *: Not allowed to be installed in T6. CAUTION Handling precaution: IEC (Electrical installations in hazardous areas) requires a label indicating simple apparatus. Stick this label to this sensor if necessary. ー iii

5 Blank Page

6 v PH4/OR4 Sensor Series ph and ORP Sensors IM 12B10B00-01EN 7th Edition CONTENTS Introduction...i Safety Precautions...ii 1. Application Specifications Model and Suffix Codes Wiring Diagrams8 5. Dimensions Use Preparing Electrical wiring Procedure for Assembling of Sensor into Holder Storage Regenerating General Revision Record...

7 Blank Page

8 1. Application 1 Selection of ph sensor ph sensor PH4P PH4F PH4C Application PH4PT PH4FT PH4CT PH4FE General purpose*1 Contaminated solutions R N N N Solutions containing sulfide ion R N L L Electrolytic process solutions N N R N Solutions containing organic solvents L N R R Waste water containing hydrofluoric acid *2 N R N N Fermentation (sterilization process) N N N R R: Recommended, L: Limited, N: Not Applicable *1: Refer to GS 12B07B02-E. *2: Confirm the specifications of hydrofluoric acid concentration upper limit. Note: The information in the table above is for reference purpose only. Consult our sales personnel about selection of ph sensor. Selection of ORP sensor ORP sensor OR4P OR4C Application Platinum Platinum General purpose*1 Drainage treatment Cyanogen treatment N N Chrome treatment N N Contaminated solutions*2 L L Solutions containing sulfide ion R L Electrolytic process solutions N R R: Recommended, L: Limited, N: Not Applicable *1: Refer to GS 12B07B02-E. *2: If contaminations are easy to precipitate on OR4P s platinum wire, select OR4C with platinum ring. Note: This table above is just for reference purpose only. Consult our sales personnel about selection of ph sensor.

9 2. Specifications Measuring range ph 2 to 14 Measuring temperature *2 Measuring pressure *2 Inner solution in reference electrode Silver ion trap in reference electrode PH4P PH4PT OR4P PH4F PH4FT PH4C PH4CT OR4C PH4FE -00 to -00 to ph 2 to 11 *1 ph 0 to mv +00 mv ph 0 to 12 0 to 105 C 0 to 110 C 0 to 80 C 0 to 100 C (Sterilization temperature: 2 maximum 130 C) Atmospheric pressure to 1.6MPa (Temperature 25 C) Atmospheric pressure to 250kPa Atmospheric Atmospheric pressure to 600kPa (Temperature 100 C) *3 pressure to 600kPa Polymer electrolyte including KCl *4 None High viscosity gel including KCl Available Diaphragm Open junction x 2 Ceramic junction x 1 Liquid earth RTD (Temperature element Insertion Length Glass tube diameter Wetted part material None *5, *6 Pt1000 None None *5, *6 120 mm None Pt mm None *5, *6 Pt1000 None Viscous 3M KCl-LR Ceramic junction x 3 None *5 120, 200, 250 mm *7 Body Glass Glass, Glass, Glass platinum platinum Glass O-ring Ethylene Propylene Diene Rubber Fluororubber (FPM) *8 (EPDM) Stainless steel (SUS316) (option code: /S3), Adapter Stainless steel (SUS316) (option code: /S3), Polypropylene (option code: /PP) or Rigid polyvinyl chloride (option code: /PV) Polypropylene (option code: /PP), Rigid polyvinyl chloride (option code: /PV), Heat-resistant Vinyl Chloride (option code: / HPV) or Titanium (option code: /TN) ORP element Pt (Wire) Pt (Ring) Head form S8 VP6 S8 S8 VP6 S8 VP6 S8 S7 Cable S8/S7 VP6 S8/S7 VP6 S8/S7 VP6 S8/S7 Cable jacket material Polyvinyl Chloride (PVC) Cable measuring -20 to 70 C -30 to 70 C -20 to 70 C -30 to 70 C -20 to 70 C -30 to 70 C -20 to 70 C temperature Applicable Flow-through holder (PH8HF), Submersion holder (PH8HS) *9 *10 holder Note: Above sensors cannot be used outdoors or with a guide pipe holder. Installation from lower position or a horizontal position is not possible.install to the vertical position of more than degrees against the horizontal position. *1: The upper limitation of hydrofluoric concentration is as below. ph2 Maximum 500 ppm ph3 Maximum 1000 ppm ph4 Maximum ppm Over ph 5 No upper limitation *2: See Table 1 when using with holder (excluding PH4FE) *3: PH4C, PH4CT and OR4C are subject to restriction of the inner pressure which remains in the sensor. *4: When used in solution contains organic solvents, Polymer may be eroded and cannot be used for long term. *5: Select manual temperature compensation on the converter or transmitter. *6: Use SA405, an adapter with temperature sensor (RTD), for application where temperature varies. *7: Shaft Length in case of PH4FE *8: Option code /PF Perfluoroelastomer (FFKM) can be selected for O-ring material when used ph sensor (excluding PH4FE). *9: An option adapter is needed, but not needed when using SA405, an adapter with temperature sensor (RTD). Ultrasonic cleaning is not available. Use a holder with jet cleaning equipment when automatic cleaning is necessary. Use O-ring covered by Teflon (K9148MR) when using a special holder for electrolytic process for PH4C, PH4CT or OR4C. *10: PH4FE cannot be used with PH8HF or PH8HS. When a holder is needed, consult our sales personnel.

10 Table 1 Process Temperature Range, Process Pressure Range Holder Type Submersion (PH8HS) Flowthrough (PH8HF) *1 Holder Material PP, SUS *2 PP SUS *2 Cleaner Adapter ph/orp Range Temperature Material ( C) PVC 0 to 50 None PP, SUS PH4P, PH4PT: 0 to 100 *4 *2 PVC ph 2 to 14 0 to 50 Provided *3 PP, SUS PH4F, PH4FT: 0 to 80 *2 PVC ph 2 to 11 0 to 50 None, PP, SUS Provided *3 0 to 80 *2 PH4C, PH4CT: PVC ph 0 to 14 0 to 50 None PP 0 to 80 SUS *2 OR4P, OR4C: 0 to 100 *4 PP, SUS -00 to 00 mv 0 to 80 Provided *3 *2 PVC 0 to 50 PVC: Rigid Polyvinyl Chloride, PP: Polypropylene, SUS: Stainless Steel (SUS316) *1: For Flow-through types also refer to temperature and pressure diagram of Holder GS 12J05C02-00E. *2: Stainless steel holder and stainless steel adapter should be used if the solution is ph 3 more acidmic. *3: Only jet cleaning system can be used. *4: When PH4F or PH4FT is used, temperature upper limit is 80 C. *5: Measurable pressure decreases when the inner pressure of PH4C, PH4CT or OR4C decreases. Process Pressure Atmospheric pressure (Submersion depth: Max. 3m) 3 PH4P, PH4PT, OR4P PH4F, PH4FT: Atmospheric pressure to 500 kpa PH4C, PH4CT, OR4C *5: Atmospheric pressure to 250 kpa Specification for SA405, an adapter with temperature sensor (RTD) Applicable sensors: PH4P, PH4F, PH4C Temperature sensor (RTD): Pt1000 Wetted part (Temperature sensor cover/adapter) materials : Hastelloy C / Hastelloy C, Stainless steel (SUS316) / PEEK, Titanium / Titanium Applicable holder: Flow-through holder (PH8HF), Submersion holder (PH8HS) 3. Model and Suffix Codes Model Suffix Code Option Code Specifications PH4P PH4PT PH4F PH4FT.... Polymer Electrolyte ph Sensor *1 Polymer Electrolyte ph Sensor with RTD *2 HF-Resistant ph Sensor *1 HF-Resistant ph Sensor with RTD *2 Insertion Length mm Cable Length Terminal Type *4 D E F G N No Cable *3 3 m 5 m 10 m m 20 m Cable for PH400G (Fork Terminal) Cable for PH202, FLXA202, FLXA21 (Pin Terminal) Cable for FLXA202, FLXA21 (M4 Ring Terminal) Cable for FLXA402, PH450G, PH202/TB (M3 Ring Terminal) No Cable *3 -N Always -N Option Adapter *5 O-Ring /S3 /PP /PV /PF Stainless Steel (SUS316) Polypropylene Rigid Polyvinyl Chloride Perfluoroelastomer (FFKM) *6 *1: PH4P and PH4F can be used with SA405, an adapter with temperature sensor (RTD). *2: TIIS Ex intrinsic safety structure (TIIS Ex approval is valid only in Japan) *3: When using sensor only, select cable length -00 and Terminal type N. *4: When using Terminal box, refer to Table 2. *5: This is needed when using the holder PH8HS or PH8HF. However when PH4P or PH4F is used with SA405, an adapter with temperature sensor (RTD), the option adapter is not needed. *6: Select perfluoroelastomer when sensor is used in organic solvent, high alkaline or high temperature alkaline solution.

11 4 Table 2 Selection of terminal box Sensor RTD SA405 Terminal Type D E F G PH4P Selected WTB10-PH2 WTB10-PH6 WTB10-PH4 PH4F None PH4C None WTB10-PH1 WTB10-PH5 WTB10-PH3 PH4PT PH4FT Available WTB10-PH1 WTB10-PH5 WTB10-PH3 PH4CT OR4P OR4C None WTB10-PH1 WTB10-PH5 WTB10-PH3 PH4FE None Note: For combined system with WTB10, maximum cable length including sensor cable length should be within 20 m. Model Suffix Code Option Code Specifications OR4P. Polymer Electrolyte ORP Sensor Insertion Length mm Cable Length Terminal Type *2 D E F G N No Cable *1 3 m 5 m 10 m m 20 m Cable for PH400G (Fork Terminal) Cable for PH202, FLXA202, FLXA21 (Pin Terminal) Cable for FLXA202, FLXA21 (M4 Ring Terminal) Cable for FLXA402, PH450G, PH202/TB (M3 Ring Terminal) No Cable *1 -N Always -N Option Adapter *3 /S3 /PP /PV Stainless Steel (SUS316) Polypropylene Rigid Polyvinyl Chloride *1: When using only sensors, select cable length -00 and Terminal type N. *2: When using Terminal box, refer to Table 2. *3: This is needed when using the holder PH8HS or PH8HF.

12 5 Model Suffix Code Option Code Specifications PH4C. ph Sensor for Chemical Process *1 PH4CT. ph Sensor for Chemical Process with RTD *2 Insertion Length mm Cable Length Terminal Type *4 D E F G N No Cable *3 3 m 5 m 10 m m 20 m Cable for PH400G (Fork Terminal) Cable for PH202, FLXA202, FLXA21 (Pin Terminal) Cable for FLXA202, FLXA21 (M4 Ring Terminal) Cable for FLXA402, PH450G, PH202/TB (M3 Ring Terminal) No Cable *3 -N Always -N Option Adapter *5 O-Ring /S3 /PP /PV /HPV /TN /PF Stainless Steel (SUS316) Polypropylene Rigid Polyvinyl Chloride Heat-resistant Vinyl Chloride Titanium Perfluoroelastomer (FFKM) *6 *1: PH4C can be used with SA405, an adapter with temperature sensor (RTD). *2: TIIS Ex intrinsic safety structure (TIIS Ex approval is valid only in Japan) *3: When using sensor only, select cable length -00 and Terminal type N. *4: When using Terminal box, refer to Table 2. *5: This is needed when using the holder PH8HS or PH8HF. However when PH4P or PH4F is used with SA405, an adapter with temperature sensor (RTD), the option adapter is not needed. *6: Select perfluoroelastomer when sensor is used in organic solvent, high alkaline or high temperature alkaline solution. Model Suffix Code Option Code Specifications OR4C. ORP Sensor for Chemical Process Insertion Length mm Cable Length Terminal Type *2 D E F G N No Cable *1 3 m 5 m 10 m m 20 m Cable for PH400G (Fork Terminal) Cable for PH202, FLXA202, FLXA21 (Pin Terminal) Cable for FLXA202, FLXA21 (M4 Ring Terminal) Cable for FLXA402, PH450G, PH202/TB (M3 Ring Terminal) No Cable *1 -N Always -N Option Adapter *3 /S3 /PP /PV /HPV /TN Stainless Steel (SUS316) Polypropylene Rigid Polyvinyl Chloride Heat-resistant Vinyl Chloride Titanium *1: When using sensor only, select cable length -00 and Terminal type N. *2: When using Terminal box, refer to Table 2. *3: This is needed when using the holder PH8HS or PH8HF.

13 6 Model Suffix Code Option Code Specifications PH4FE. ph Sensor for Fermentation Shaft Length Cable Length Terminal Type D E N 120 mm 200 mm 250 mm -N Always -N No Cable *1 3 m 5 m 10 m m 20 m Cable for PH400G (Fork Terminal) Cable for PH202, FLXA202, FLXA21 (Pin Terminal) No Cable *1 *1: When using sensor only, select cable length -00 and Terminal type N. SA405, adapter with temperature sensor (RTD) Model Suffix Code Option Code Specifications SA405. Adapter with temperature sensor Measuring System -A -E -F -G Material of Temp. Sensor Cover/ Adapter -HC -S3 -TN Cable Length for PH400G *1 for PH202/FLXA202/FLXA21 *2 for FLXA202/FLXA21 *4 for FLXA402, PH450G, PH202/TB *3 Hastelloy C / Hastelloy C Stainless steel (SUS316) / PEEK Titanium / Titanium 3 m 5 m 10 m m 20 m *1: Mark band is shown by alphabet and fork terminals are used. *2: Mark band is shown by numerals and pin terminals are used. When terminal box is used, select WTB10-PH2. *3: Mark band is shown by numerals and M3 ring terminals are used. When terminal box is used, select WTB10-PH4. *4: Mark band is shown by numerals and M4 ring terminals are used. When terminal box is used, select WTB10-PH6. Spare Parts Part Name Part Number Remarks 3 m K9691MA For PH4P, OR4P, PH4F, PH4C, OR4C, PH4FE 5 m K9691MB 10 m K9691MC Fork Terminal m K9691MD Cable for PH400G, 20 m K9691ME OR400G 3 m K9691NA For PH4PT, PH4FT, PH4CT Terminal Type: D 5 m K9691NB 10 m K9691NC m K9691ND 20 m K9691NE

14 Part Name Part Number Remarks 3 m K9691PA For PH4P, OR4P, PH4F, PH4C, OR4C, PH4FE 5 m K9691PB 10 m K9691PC Pin Terminal Cable m K9691PD for PH202, FLXA202, 20 m K9691PE FLXA21 3 m K9691QA For PH4PT, PH4FT, PH4CT Terminal Type: E 5 m K9691QB 10 m K9691QC m K9691QD 20 m K9691QE 3 m K9691RA For PH4P,OR4P, PH4F, PH4C, OR4C 5 m K9691RB 10 m K9691RC M4 Ring Terminal m K9691RD Cable for FLXA202, 20 m K9691RE FLXA21 3 m K9691RN For PH4PT, PH4FT, PH4CT Terminal Type: F 5 m K9691RP 10 m K9691RQ m K9691RR 20 m K9691RS M3 Ring Terminal Cable for FLXA402, PH450G, PH202/TB Terminal Type: G Adapter O-Ring 3 m K9691SA For PH4P, OR4P, PH4F, PH4C, OR4C 5 m K9691SB 10 m K9691SC m K9691SD 20 m K9691SE 3 m K9691SN For PH4PT, PH4FT, PH4CT 5 m K9691SP 10 m K9691SQ m K9691SR 20 m K9691SS Stainless Steel (SUS316) K9148NA For PH4P, PH4PT, OR4P, PH4F, PH4FT, PH4C, Option code: /S3 PH4CT, OR4C Polypropylene K9148NB Option code: /PP Rigid Polyvinyl Chloride K9148NC Option code: /PV Heat-resistant Vinyl K9148ND For PH4C, PH4CT, OR4C Chloride Option code: /HPV Titanium K9148NE Option code: /TN Perfluoroelastomer K9319RJ For PH4P, PH4PT, PH4F, PH4FT, PH4C, PH4CT, (FFKM) Option code: /PF Fluororubber (FPM) K9691KA For PH4P, PH4PT, OR4P, PH4F, PH4FT Ethylene Propylene K9691KB For PH4C, PH4CT, OR4C Diene Rubber (EPDM) Electrolyte Viscous 3 M KCl-LR K9691KK For PH4FE (500mL) Buffer solution for calibration (ph4) K9084LL Six 250 ml polyethylene bottles Buffer solution for calibration (ph7) K9084LM Six 250 ml polyethylene bottles Buffer solution for calibration (ph9) K9084LN Six 250 ml polyethylene bottles Powder for buffer solution (ph4) K9020XA 12 bags, each for preparation of 500 ml Powder for buffer solution (ph7) K9020XB 12 bags, each for preparation of 500 ml Powder for buffer solution (ph9) K9020XC 12 bags, each for preparation of 500 ml Reagent for ORP check Quinhydrone K9024EC 3 bags, each for preparation of 250 ml Iron K9024ED 3 bags, each for preparation of 250 ml Note: The ph value of the calibrating buffer solution may vary depending on storage conditions. 7

15 4. Wiring Diagrams Mark (alphabet / number) of cable core of ph sensor depends on terminal form. 8 In case of PH4, PH4FE ph sensor, OR4 ORP sensor Mark of cable core of ph sensor PH4P PH4F PH4C PH4FE OR4P OR4C GE SE RE () (14) (13) Mark of terminal of Converter/Transmitter PH400G FLXA202 FLXA21 PH202 FLXA402 PH Note: Since RTD is not available, there is no wire connection to Converter/Transmitter 11 (T1) or 12 (T2). There is no wire connection to Converter/Transmitter 16 (S). In case of PH4 T ph sensor with RTD Mark of cable core of ph sensor PH4PT PH4FT PH4CT GE SE SE RE T2 T1 () (14) (14) (13) (12) (11) FLXA202 FLXA21 PH202 FLXA402 PH S GE SE RE T2 T1 S GE SE RE T2 T1 F01.ai Mark of terminal of Converter/Transmitter PH400G Note: 2 cable cores of ph sensor should be connected to the terminal of Converter/Transmitter 14 (SE). There is no wire connection to Converter/Transmitter 16 (S). When using Terminal box WTB10 F02.ai No combination with SA405 ph sensor with RTD WTB10-PH1, 3, 5 *1 Terminal Box ph Converter/ Transmitter WTB10-PH1, 3, 5 *1 Terminal Box ph Converter/ Transmitter PH4P PH4F PH4C * PH4PT PH4FT PH4CT * Combination with SA405 PH4P PH4F PH4C SA405 WTB10-PH2, 4, 6 *1 Terminal Box *2 ph Converter/ Transmitter ORP sensor WTB10-PH1, 3, 5 *1 Terminal Box OR4P 16 OR4C * ORP Converter/ Transmitter *1: Terminal box is used only where ph/orp transmitter is installed remotely from ph or ORP sensor (normally not needed). Refer to Table 2 for WTB10 type. *2: This cable is specified in the option code for the terminal box. For combined system with WTB10, maximum cable length including sensor cable length should be within 20m F03.ai

16 5. Dimensions 9 PH4P PH4F PH4C Polymer Electrolyte ph Sensor HF-Resistant ph Sensor ph Sensor for Chemical Process Unit: mm Approx. ø12 O-ring PG13.5 S8 PH4PT Polymer Electrolyte ph Sensor with RTD PH4FT HF-Resistant ph Sensor with RTD PH4CT ph Sensor for Chemical Process with RTD Unit: mm Approx. ø12 O-ring PG13.5 TIIS explosion-proof Tag (Valid only in Japan) VP6 OR4P Polymer Electrolyte ORP Sensor Unit: mm Approx. ø12 O-ring PG13.5 S8 OR4C ORP Sensor for Chemical Process Unit: mm Approx. ø12 O-ring PG13.5 S8

17 10 PH4FE ph Sensor for Fermentation L (L=120, 200, 250) 203 Unit: mm ø30 Approx. ø12 Electrode solution (Inner solution) Inner solution refilling vent S7 Cable S8/S7 cable for PH4P, OR4P, PH4F, PH4C, OR4C, PH4FE Approx. ø5 Approx. ø6.5 Unit: mm Approx. 100 Approx. 90 Cable length (approx. 3m, 5m, 10m, m, 20m) Terminal Type: D Terminal Type: E Note: There is no terminal type F or G for PH4FE. Terminal Type: F, G

18 11 VP6 cable for PH4PT, PH4FT, PH4CT Cable length (approx. 3m, 5m, 10m, m, 20m) Unit: mm Approx. ø7.5 Terminal Type: D Terminal Type: E Terminal Type: F, G Adapter (Option code: /S3, /PP, /PV, /HPV, /TN) ø38 ø26.5 Unit: mm ø12.5 ø30.5

19 12 SA405, adapter with temperature sensor (RTD) ø Unit: mm (L+270)±50 ( L=3, 5, 10,, 20m ) Temperature sensor (Pt 1000) ø38 ø30.5 Adapter ø26.5 Temperature sensor cable Ring terminal Pin terminal Fork terminal 6. Use This sensor is only to be used for the intended purpose and under safe conditions. Improper use or misuse can be dangerous. CAUTION Since these sensors are made of glass, they should be handled with care. Take care that the PG13.5 thread and the O-ring are not damaged while the sensor is installed into the adapter etc. 6.1 Preparing Carefully remove the storage cap by turning a screw located at a blue gasket. Rinse the sensor with water. Check the interior of the ph glass membrane for air bubbles. Allow any bubbles to rise to the top by shaking the sensor gently. PH4FE sensor: Prior to measuring, open the reservoir stopper; close it after measuring. Check level of electrolyte in the sensor. 6.2 Electrical wiring The sensors are equipped with a S8, S7 or a VP connector head. Before connecting the sensor to the cable, check that the connections are clean and dry. Do not touch the electrical contacts! Connectors especially should not be disconnected in moisture condensing environments. Unstable signals, low slope or long response time could indicate a moist or contaminated connector. Clean the connector head with a paper towel moistened with ethanol. Dry the connector head after this procedure with a dry paper towel. Attaching/detaching method of sensor cable In case of VP connector Rotating the sensor connector so that its recessed portions will agree with the salient portions inside the cable connector, insert the sensor connector into the cable connector. A weak pressure is sufficient for inserting it. If a strong pressure is needed to insert it, the connection position will be incorrect. Check the position and re-try.

20 After inserting the sensor connector completely, grip the portion A, and rotate the cap nut ( B portion) clockwise until the nut cannot rotate. Gripping the portion A, and rotate the cap nut ( B portion) un-clockwise. After loosing the nut completely, grip and pull the plastic portion of the sensor from the cable connector. CAUTION Do not grip or rotate the glass body of the sensor, but the plastic body of the connector. If the glass body is gripped, the sensor may be broken. 13 A B A Recess for positioning the sensor and cable B TIIS explosion-proof Tag (Attached only to PH4 T, but valid only in Japan) (Sensor side) (Sensor side) Attaching/detaching NOTE TIIS explosion approval is valid only in Japan, hence users remove TIIS explosion-proof tag and may use PH4 T in hazardous area, or non-hazardous area except Japan. NOTE If conduit is used, the metal part of the cable connector should not be in contact with metal parts of the conduit. If the metal part of the cable connector is in contact with other metal parts, this may cause measurement errors. 6.3 Procedure for Assembling of Sensor into Holder Install a sensor where a cable is connected according to 6.2 in a holder, when a holder is used. For use of the model PH8HF flow-through holder (1) Remove the nut for fixing the sensor to the adapter. (2) Pass the cable through the nut. (3) Attach the O-ring attached inside the holder, to the adapter. (Refer to the O-ring position in below figure.) (4) Put the sensor into the holder, and fix the adapter by screwing the nut.

21 14 For use of the model PH8HS submersion holder (1) Remove the protector and piece of foam rubber. This rubber is for transportation. (2) Pass the O-ring through the cable, and mount it to the upper side of the adapter. (Refer to the O-ring position in below figure.) (3) Pass the cable through the holder from the protector attachment side, and fix the sensor by the protector. (4) Fix the sensor cable to the holder. Thread for attaching to the sensor O-Ring position for using the PH8HS holder Adapter O-Ring position for using the PH8HF holder 6.4 Storage Sensors should be stored with the storage cap attached, containing 1.5 to 2 ml of 3.3 mol/l KCl solution. Sensors stored dry exhibit temporary drifting values. If the sensor dries out inadvertently, it can be placed in 3.3 mol/l KCl solution, or ph standard buffer solution overnight to regenerate. 6.5 Regenerating Entire regenerating is not always guarantee. ph: Immerse sensor for 10 min in 0.1 1M NaOH, then for 10 min in 0.1 1M HCl. After regeneration, place the sensor in 3.3 mol/l KCl solution for a further min. ORP: Metal surfaces can be cleaned with slightly abrasive substances, such as toothpaste or very fine scouring powder. 6.6 General The life cycle of sensors is determined by requirements regarding response time, zero point and slope. Some of harsh measurement conditions might shorten life cycle. There is also a slight ageing factor during storage, therefore avoid a long period of storage. Use within a year is recommended. O-rings are subject to wear and tear and should be replaced regularly, at least once per year. Refer to spare parts regarding the parts number of O-rings. For Models PH4C, PH4CT, OR4C The new sensor is pre-pressurized at about 250 kpa. This pressure, after one year, at the liquid junction, will decrease to about half at normal ambient temperatures and atmospheric pressure. Taking this decrease into account, use the sensor. If the pressure of a sample solution becomes higher than the inner pressure of the sensor, the solution will permeate gel electrolyte in the sensor. As a result, the sensor can become unusable. A rough change of the sensor inner pressure can be known by the air layer length of a narrow tube in the sensor. The higher the internal pressure, the shorter the air layer. For sensors with temperature sensor, RTD (Models PH4PT, PH4FT, PH4CT) Sensors with a VP type connection have a built-in temperature sensor (Pt1000). This temperature sensor is to be used only to compensate the ph signal and not to control process temperature.

22 Revision Record Manual Title : PH4/OR4 Sensor Series ph and ORP Sensors Manual No. : IM 12B10B00-01EN Nov. 2018/7th Edition Added FLXA402, correction (pages i, 1, 3 to 8) Mar. 2018/6th Edition Page 1, the tables of Selection of ph/orp Sensor were revised. Aug. 2017/5th Edition TIIS explosion-proof Tag was attached for PH4 T (pages 3, 5, 9, 13) Correction (pages i, iii, 4, 5, 6, 7, 8) Nov. 2016/4th Edition Page iii, the table was corrected. Oct. 2016/3rd Edition Page iii had an additional table. Page 1 tables were revised. Page 8 had an additional statement on WTB wiring diagram. Jul. 2016/2nd Edition Page ii Compliance with the simple apparatus requirements with additional description in CAUTION Page 1 the table Selection of ORP Sensor was revised. Page 2 and Page 3 were revised on Specification. Aug. 20/1st Edition Newly published

23 Blank Page

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor PH4P/PH4PT,

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor /T, HF-resistant

More information

Model FU20 ph/orp Sensor

Model FU20 ph/orp Sensor User s Manual Model FU20 ph/orp Sensor 4th Edition INTRODUCTION This user s manual provides information for the installation and use of the FU20 ph/orp sensor. The FU20 is the choice for

More information

Model PH8ERP KCl Refillable type ph Sensor

Model PH8ERP KCl Refillable type ph Sensor User s Manual Model PH8ERP KCl Refillable type ph Sensor R 7th Edition Blank Page INTRODUCTION This manual covers the PH8ERP KCl Refillable type ph Sensor. Other related items are described in the following

More information

Model PH8EHP ph Sensor for High Purity Water

Model PH8EHP ph Sensor for High Purity Water User s Manual Model PH8EHP ph Sensor for High Purity Water R 7th Edition Blank Page INTRODUCTION This manual covers the PH8EHP ph Sensor for High Purity Water. Other related items are described in the

More information

Model PH8HG Drop-in Guide Pipe

Model PH8HG Drop-in Guide Pipe User s Manual Model PH8HG Drop-in Guide Pipe R 3rd Edition Blank Page INTRODUCTION This manual covers the PH8HG drop-in guide pipe. Other related items are described in the following manuals:

More information

Model OR8ERG KCl Refillable type ORP Sensor

Model OR8ERG KCl Refillable type ORP Sensor User s Manual Model OR8ERG KCl Refillable type ORP Sensor R 5th Edition INTRODUCTION This manual covers the OR8ERG KCl Refillable type ORP Sensor. Other related items are described in the

More information

Model OR8ERG KCl Refillable type ORP Sensor

Model OR8ERG KCl Refillable type ORP Sensor User s Manual Model OR8ERG KCl Refillable type ORP Sensor R 4th Edition Blank Page INTRODUCTION This manual covers the OR8ERG KCl Refillable type ORP Sensor. Other related items are described in the following

More information

General Specifications

General Specifications General Specifications DO0G Sensor for Dissolved Oxygen Analyzer GS 2J05D0-0E GENERA The DO0G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent

More information

Model PH8EFP KCl Filling type ph Sensor

Model PH8EFP KCl Filling type ph Sensor User s Manual Model PH8EFP KCl Filling type ph Sensor R 6th Edition Blank Page INTRODUCTION This manual covers the PH8EFP KCl Filling type ph Sensor. Other related items are described in the following

More information

General Specifications

General Specifications General Specifications DO30G Sensor for Dissolved Oxygen Analyzer GS 2J05D03-0E GENERA The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works,

More information

Model PH8EFP KCl Filling type ph Sensor

Model PH8EFP KCl Filling type ph Sensor User s Manual Model PH8EFP KCl Filling type ph Sensor R 7th Edition Blank Page INTRODUCTION This manual covers the PH8EFP KCl Filling type ph Sensor. Other related items are described in the following

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

Model PH8HF, PH8HFF Flow-Through Type Holder

Model PH8HF, PH8HFF Flow-Through Type Holder User s Manual Model PH8HF, PH8HFF Flow-Through Type Holder 5th Edition INTRODUCTION This manual covers the PH8HF, PH8HFF Flow-Through Type Holder. Other related items are described in the

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

Model ST401G Sampling System

Model ST401G Sampling System User s Manual Model ST401 Sampling System R 6th Edition Blank Page INTRODUCTION This manual explains the installation, operation and use of the sampling system. Read through this manual

More information

User s Manual Model PH10RP KCl Replenish-free ph Sensor

User s Manual Model PH10RP KCl Replenish-free ph Sensor User s Manual Model PH10RP KCl Replenish-free ph Sensor 1st Edition Safety Precautions Introduction This instruction manual covers the PH10RP KCl Replenish-free ph sensor for the PH100. Other related EXA100

More information

General Specifications

General Specifications General Specifications Chemical Cleaning ph Measuring System GS B7A-E General Process ph measuring systems have played an important role in many fields including the chemical, food, metal, and paper pulp

More information

General Specifications

General Specifications eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial

More information

Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters Personal ph, ph/orp, Meters // Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/ Compact and lightweight 220g IP67 Waterproof CE,RCM,KC Various Convenient Data memory Alarm Clock Date/time

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

General Specifications

General Specifications General Specifications Model -FTS Differential ph/orp-sensor Overview The -FTS is the newest development in ph sensor technology available from Yokogawa. This sensor combines the measuring technology of

More information

General Specifications

General Specifications General Specifications Model PH20 and FU20 ph/redox and Temperature sensor The PH20 is nicknamed "Tempress" because of the patented compensation for changes in the process temperature and pressure. This

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Orbipore CPS91 and CPS91D

Orbipore CPS91 and CPS91D Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical

More information

ph (ORP) SENSOR ASSEMBLY

ph (ORP) SENSOR ASSEMBLY Specifications Sheet No.SPEC-3109E (3rd Edition) SP ph (ORP) SENSOR ASSEMBLY SPECIFICATIONS Flow-Through Type Probe Electrode holder for pipe line or sampling method Model SP3101 SP3111 Process connection

More information

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor Models 396/396P/396R Product Data Sheet PDS 71-TUpH September 1999 Retraction/Submersion/Insertion ph/orp Sensor MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology 1 which ensures steady

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Visit us at

Visit us at Instruction Manual testo 205 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors Product Data Sheet PDS 71-3900/rev. B December 2010 Models 3900 and 3900VP General Purpose ph/orp Sensors EXTENDED SENSOR LIFE provided by double junction reference. ENHANCED PERFORMANCE AND INCREASED

More information

PH60 Series Premium ph Testers

PH60 Series Premium ph Testers PH60 Series Premium ph Testers Instruction Manual PH60 ph Tester PH60S Spear ph Tester PH60F Flat ph Tester APERA INSTRUMENTS (Europe) GmbH www.aperainst.de v5.6 Thank you for purchasing the Apera Instruments

More information

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung de Instruction Manual en 18 General Information General Information Please read this document through carefully and familiarise yourself

More information

General Specifications

General Specifications General Specifications Model PH20, FU20 and FU24 4 in 1 ph sensor GS 12B6J3-01E-A Yokogawa s family of wide body sensors is suited for a wide variety of processes. The sensors share the same unique features:

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

User s Manual. CONDUCTIVITY METERING SYSTEM Model SC210G CONDUCTIVITY DETECTOR IM 12D08G03-01E IM 12D08G03-01E. 14th Edition

User s Manual. CONDUCTIVITY METERING SYSTEM Model SC210G CONDUCTIVITY DETECTOR IM 12D08G03-01E IM 12D08G03-01E. 14th Edition User s Manual CONDUCTIVITY METERING SYSTEM Model SC210G CONDUCTIVITY DETECTOR IM 12D08G03-01E IM 12D08G03-01E 14th Edition Introduction < Introduction > i Conductivity Measuring System consists of a SC210G

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

Bante220 Portable ph Meter Instruction Manual

Bante220 Portable ph Meter Instruction Manual Bante220 Portable ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante220 Portable ph Meter 1 Introduction Thank you for selecting the Bante220 portable ph meter. This manual provides a step-by-step

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

General Specifications

General Specifications General Specifications GS 1C2H1-E Model EJ11W, EJ11N and EJ11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium from entering directly

More information

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information

More information

Model PH8HH ph Holder for High Purity Water

Model PH8HH ph Holder for High Purity Water User s Manual Model PH8HH ph Holder for High Purity Water R 3rd Edition Toc-1 Model PH8HH ph Holder for High Purity Water 3rd Edition CONTENTS 1. Overview... 1-1 1.1 Standard Specifications...

More information

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED ECscan10H Pocket Conductivity Tester Instruction Manual BANTE INSTRUMENTS LIMITED ECscan10H Pocket Conductivity Tester 1 Introduction Thank you for selecting the ECscan10H pocket conductivity tester. This

More information

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D Technical Information Orbisint CPS11 and CPS11D ph electrodes, analog or with digital Memosens technology For standard applications in process and environment technology, with dirt-repellent PTFE diaphragm,

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Model FLXA21 2-Wire Analyzer Start-up Manual

Model FLXA21 2-Wire Analyzer Start-up Manual User s Manual Model FLXA21 2-Wire Analyzer Start-up Manual IM 12A01A02-12E This Start-up Manual explains mainly the installation and wiring of the FLXA21. For detailed information and other information,

More information

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply IM E. 5th Edition User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures

More information

Model TB400G Surface Scattering Light Turbidity Meter [Style: S3]

Model TB400G Surface Scattering Light Turbidity Meter [Style: S3] User s Manual Model TB400G Surface Scattering Light Turbidity Meter [Style: S3] IM 12E04A02-02E IM 12E04A02-02E 7th Edition INTRODUCTION i Structure of this Manual This manual describes the specifications,

More information

General Specifications

General Specifications General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor User Manual English SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor Memosens Protocol Latest Product Information: www.knick.de 2 Safety Instructions WARNING Failure to observe this warning may result

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

General Specifications

General Specifications General Specifications GS 12D06B01-01E ISC40 J Inductive Conductivity Sensors ISC40F J Holders and Adapters GENERAL The ISC40 J sensors are designed for use with the FLXA202/FLXA21 2-wire Analyzer, ISC202

More information

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes 7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes 70-82-25-44 Rev. 1 10/07 Honeywell Process Solutions Copyright, Notices, and Trademarks Copyright 2007 by Honeywell

More information

General Specifications

General Specifications General Specifications Models RM and RH Resistance Temperature Sensor GS 06B03B01-00E GENERAL Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual 70-82-25-05 Rev. 1 3/08 Honeywell Process Solutions Copyright, Notices, and Trademarks Printed in U.S.A.

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

TDSscan10M Pocket TDS Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual TDSscan10M Pocket TDS Tester Instruction Manual BANTE INSTRUMENTS CO., LTD TDSscan10M Pocket TDS Tester 1 Thank you for selecting the TDSscan10M pocket TDS tester. This manual provides a step-by-step guide

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Technical Information Ceraliquid CPS41D and CPS41

Technical Information Ceraliquid CPS41D and CPS41 TI00079C/07/EN/13.15 71277561 Products Solutions Services Technical Information Ceraliquid CPS41D and CPS41 ph electrodes, digital with Memosens technology, and analog For process engineering with ceramic

More information

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS REV. 3.1 Water Analytics, Inc. 100 School Street Andover, MA 01810 978-749-9949 Toll free: 855-747-7623 Fax: 978-749-9961 www.wateranalytics.net

More information

8000 Series ph/orp Electrode Platform Product Instructions

8000 Series ph/orp Electrode Platform Product Instructions 8000 Series ph/orp Electrode Platform Product Instructions Introduction Congratulations on your purchase of your Sensorex S8000 series electrode platform. The platform is designed in a modular fashion

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Pressure Transmitter

Pressure Transmitter Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

PHscan10S Pocket ph Tester Instruction Manual

PHscan10S Pocket ph Tester Instruction Manual PHscan10S Pocket ph Tester Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan10S Pocket ph Tester 1 Thank you for selecting the PHscan10S pocket ph tester. This manual provides a step-by-step guide to

More information

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition Instruction Manual Models FD30 / PB30 Fittings for the DO30G 6th edition 2 Table of contents 1. Introduction...3 2. Unpacking and checking...3 3. Warranty and service...3 4. Genral specifications...4 4-1.

More information

General Specifications

General Specifications General Specifications Model SS400 MLSS Analyzer GS 12E6A1-E General The Model SS400 MLSS Analyzer is a measuring system best suited to continuously and consistently measure the concentration of mixed

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J5C2-E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up analyzers

More information

Visit us at

Visit us at Instruction Manual testo 206 ph/ Temperature Measuring Instrument 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 2 General Information

More information

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY WARRANTY USER S GUIDE ONE YEAR LIMITED WARRANTY The PH-200, manufactured by HM Digital, Inc. ("the Company") is warranted to the purchaser against defective materials and workmanship for one (1) year from

More information

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Product Data Sheet LIQ-PDS-396P-PVP-R-RVP April 2016 TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP Retraction/Submersion/Insertion ph/orp Sensors Smart enabled

More information

DATA SHEET ORGANIC THERMAL SENSITIVE PELLET TYPE 10 AMPERES RATED CURRENT

DATA SHEET ORGANIC THERMAL SENSITIVE PELLET TYPE 10 AMPERES RATED CURRENT DATA SHEET Thermal Cutoff SEFUSE TM SF/E SERIES ORGANIC THERMAL SENSITIVE PELLET TYPE 1 AMPERES RATED CURRENT NEC's thermal cutoff SE/E series is small, solid and reliable product which can be used under

More information

PHscan30S Pocket ph Meter Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual PHscan30S Pocket ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan30S Pocket ph Meter 1 Thank you for selecting the PHscan30S pocket ph meter. This manual provides a step-by-step guide to help

More information

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Technical Information Cleanfit P CPA472D Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Application Chemical industry Power plants Plant design Tanks and process

More information

General Specifications

General Specifications General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order

More information

Orbisint CPS12/CPS12D/CPS13

Orbisint CPS12/CPS12D/CPS13 Technical Information Orbisint CPS12/CPS12D/CPS13 ORP electrodes, analog and digital with Memosens technology and reference electrode Each with dirt-repellent PTFE diaphragm for standard applications in

More information

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser! Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax Bottle Top Dispenser! General Safety Precautions When using the Labmax please observe the following safety precautions

More information

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance Instruction MI 611-214 September 2012 PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance MI 611-214 September 2012 Contents Figures... Tables... v vii 1. Introduction...

More information

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC   V6.4 PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com V6.4 Thank you for purchasing Apera Instruments PC60 Premium Multi-Parameter Tester.

More information

TUpH Retraction/Submersion/Insertion ph/orp Sensors

TUpH Retraction/Submersion/Insertion ph/orp Sensors Product Data Sheet PDS 71-TUpHVP/rev.B June 2003 Models 396VP, 396RVP, 398VP, & 398RVP TUpH Retraction/Submersion/Insertion ph/orp Sensors SILCORE 3 TECHNOLOGY PROVIDES INCREASED SENSOR LIFE when used

More information

SIPAN 32 and 34. Controllers, Sensors and Accessories for ph, ORP, Conductivity and Dissolved Oxygen

SIPAN 32 and 34. Controllers, Sensors and Accessories for ph, ORP, Conductivity and Dissolved Oxygen CATALOG Supplement PROCESS MEASUREMENT TECHNOLOGY SIPAN LIQUID ANALYSIS SIPAN 32 and 34 Controllers, Senss and Accessies f ph, ORP, Conductivity and Dissolved Oxygen European Distribut Pricelist valid

More information

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement Technical Information CPM280 ph/orp measurement Battery-driven pocket meter for ph and ORP measurement Application CPM280 is a pocket meter for measuring ph value and ORP. It is suitable for the following

More information

Flow-Through Fitting ARF 215

Flow-Through Fitting ARF 215 Flow-Through Fitting ARF 215 Standard Models Model for Pressurized Sensors Latest Product Information: www.knick.de Warranty Defects occurring within 1 year from delivery date shall be remedied free of

More information

Model FLXA202 / FLXA21 2-Wire Analyzer Start-up Manual

Model FLXA202 / FLXA21 2-Wire Analyzer Start-up Manual User s Manual Model FLXA202 / FLXA21 2-Wire Analyzer Start-up Manual IM 12A01A02-12E This Start-up Manual explains mainly the installation and wiring of the FLXA202/FLXA21. For detailed information and

More information

SIGNET 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap ENGLISH 3-3719.090 B-6/02 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not attempt to disassemble the retraction

More information

General Specifications

General Specifications General Specifications Compact ph Probes Model EXA Series EXA Compact is a versatile series of probes suitable for ph measurements in all common applications in industrial processes and (waste) water treatment

More information

Retractable ph/orp Sensors

Retractable ph/orp Sensors Model 396R and 396RVP Instruction Manual PN 5100396R January 2001 Retractable ph/orp Sensors ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures, and tests

More information

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/ Operating Instructions Flowfit W CPA250 Flow assembly for ph/orp sensors BA041C/07/en/02.07 51517581 Brief overview Fig. 1: CPA250 with Sensor 1 Reference bore 1) for electrolyte supply from reservoir

More information

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation User s Manual 701934 Power Supply Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the 701934 Power Supply. This user's manual contains useful information about the

More information

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity

More information

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info CDCE-90-X SERIES Conductivity Sensors omega.com info@omega.com U.S.A. Headquarters: Servicing

More information

OPERATING INSTRUCTION MANUAL

OPERATING INSTRUCTION MANUAL OPERATING INSTRUCTION MANUAL MODEL P/R65 DIFFERENTIAL 2-WIRE (4-20 ma) ph & ORP PROBES N116-139 REV. 0 Aquametrix, by Water Analytics Inc. 100 School Street Andover, MA 01810 Tel: (978) 749-9949 Toll Free:

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973) SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D ST400D Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D

More information

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Flow Fittings. for Electrochemical Sensors. B Operating Manual / Flow Fittings for Electrochemical Sensors B 202810.0 Operating Manual 2013-06-12/0043166 Contents 1 Introduction......................................................5 1.1 Safety information.............................................................

More information

KD1E Range Potential Indicators

KD1E Range Potential Indicators KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Limited Warranty & Limitation

More information