1 General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in a metal sheath which is joined to a terminal. The metal sheath has insulating powder (MgO: magnesium oxide) packed tightly between the sheath and the sensor, so that the sensor cannot move. The tube is flexible, durable and mechanically strong, and the sensor s thermal response is fast. The Model RS has compensation leadwires terminated in crimp-on lugs or metallic connectors. The sensor can be pipe threads mounted or clamped in place. This type of sensor is suitable for laboratory use or for use with simple measuring instruments. The Model RN RTS has a nipple joined to a terminal box. It can be flange mounted, using a fixed flange, or pipe threads mounted. The terminal box of the Model RN-5 RTS contains a spring by which the RTS can be installed tightly to the measuring site. The operating temperature range depends on the resistance element; -200 C to +100 C, 0 to +350 C or 0 to +500 C. These RTSs conform to JIS standards. RTSs conforming to IEC or DIN standards are also available to order. STANDARD SPECIFICATIONS Construction: R.T.S. (mineral insulated type) Mounting Style: RS-l.... Plain insertion type RN Plain insertion type RN Flange mount type RS Pipe threads mount type RN Pipe threads mount type RN Pipe threads mount type (with nipple coupler) RN Pipe threads mount type (with nipple coupler) Terminal Style: RS..... Compensating lead wire type, connector type RN..... Terminal box type (Refer to Figure 1.) Nominal Resistance: IEC, JIS Pt 100 (at 0 C) or Pt 50 (0 C) (options) Rated Current: 1 ma, 2 ma or 5 ma. (options) Class: IEC, JIS Class A or Class B Operating Temperature Range: JIS Low temperature to 100 C JIS Medium temperature to 350 C JIS High temperature to 500 C Tolerance on Temperature: Refer to Table 1. Number of Element: Single or double. Sheath Material: Stainless steel (JIS SUS 316) Note: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150 ºC [302 ºF] or above). Contact Yokogawa for detailed information of the wetted parts material. Sheath Outside Dia.: 3.2, 4.8, 6.4 or 8.0 mm Flange and Pipe Threads Material: Stainless steel (JIS SUS 304) Mounting Flange; Rating: JIS 5K, 10K or 20K. ANSI Class 150 or Class 300. Facing: Nominal Size: RS-16 RN-41 Raised face or Flat Face. 15 mm (1/2 in.), 20 mm (3/4 in.), 25 mm (1 in.), 40 mm (1-1/2 in.) or 50 mm (2 in.). Mounting Pipe Threads; Style: JIS Straight or Tapered type. ANSI Tapered type. Nominal Size: 1/8 in., 1/4 in., 3/8 in., 1/2 in., 3/4 in. or 1 in. Sheath and Mounting Flange or Pipe Threads Combination: Refer to Table 5. Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, Japan Tel.: Fax.: GS 06B04D01-00E Copyright Mar th Edition Mar. 2006

2 2 Operating temperature range H M L Table 1. Tolerance on Temperature Measured temperature C Tolerance Class index A Class index B Temperature C Temperature C T01E.EPS Table 2. Sheath and Mounting Flange or Pipe Threads Combinations Sheath O. D. Flange nominal size Pipe threads nominal size 3.2, 4.8 mm 6.4, 8.0 mm 15 mm, 20 mm, 25 mm, 40 mm, 50 mm 15 mm, 20 mm, 25 mm, 40 mm, 50 mm 1/8 in., 1/4 in., 3/8 in., 1/2 in., 3/4 in., 1 in. 1/4 in., 3/8 in., 1/2 in., 3/4 in., 1 in. T02E.EPS Suffix code Type General type Phenol resin type Flameproof type Double element type Terminal box material Cast aluminum alloy Phenolic resin Cast aluminum alloy Cast aluminum alloy Electrical connections JIS G 1/2 or G 3/4 female JIS G 1/2 female JIS G 1/2 or G 3/4 female JIS G 1/2 female Number of terminals 3 or 6 3 or 6 3 or 6 6 Terminal material Ceramic Ceramic Epoxy resin Ceramic Finished Polyurethane paint None Polyurethane paint Polyurethane paint Color Jade green Black Jade green Jade green External Dimension (unit: mm) OPTION (Category I) With compression fitting (option code suffix: /AA) Applicable outer diameter of sheath: 4.8 or smaller JIS Rc1/8 6.4 or larger JIS Rc1/4 Bayonet mounting (option code suffix: /BN ) Applicable outer diameter of sheath: 3.2 or 4.8 Without holder: /BN0 (specify the length from sheath top to ring) With holder: /BN1 Figure 1. List of Terminal Box T03E.EPS With pad for measuring surface temperature (option code suffix: /PAD-R) Applicable outer diameter of sheath: 3.2 or 4.8 Material: JIS SUS 304 Stainless steel Pad is welded to sheath Strap for fixing sheath (option code suffix: /ST ) Fill in the number of necessary straps in of code ST. All Rights Reserved. Copyright 1985, Yokogawa Electric Corporation GS 06B04D01-00E Jan. 07,

3 With Waterproof Cap Option code /WP -15A -15B -15C -20A -20B -20C Terminal box elec. connection JIS PF 1/2 Female JIS PF 3/4 Female I. D. of packing 9 mm 10 mm 11 mm 12 mm 13 mm 15 mm Applied to terminal box General use type, Phenol resin type or Double element type General use type < NOTE > 3 Revision of JIS RTS Symbols The JIS C1604 (resistance thermometer sensors) have been changed, effective March, 1997, in order to conform to IEC standard. According to these JIS revisions, some products and documents of Instruments Div. have also been revised as follows: Note: JIS: Japanese Industrial Standard IEC: International Electrotechnical Commission With Flameproof Packing Adapter (Option code suffix: /PG) Electrical connection: JIS G1/2 Female..... for single element JIS G3/4 Female..... for double element Cable O.D.: 8.8 to 10.7 mm for JIS G1/2 female l0 to 12 mm for JIS G3/4 female With Allen Wrench (Option code suffix: /AW) For flameproof type terminal box. Special Color Finish T04E.EPS 1. Outline of JIS RTD revision 1.1 R100/R0 (resistance relationship for resistance elements) has been adopted by JIS, and the symbols have been changed: JIS RTD Symbols R100/R0 Old New Not available Pt New adopted (conforming to DIN & IEC Pt100) Pt100 JPt Shall be obsoleted in the future T06E.EPS Option code Color Finished -G1 Black Baked polyurethane /CFP -G7 Metalic silver resin finish /CFE -G1 Black -G2 Jade green -G7 Metalic silver Baked epoxy resin finish 1.2 Newly-adopted JIS Pt100 has the same characteristics as those of DIN IEC751 and IEC Pt50 has been deleted from the revised JIS Note: DIN: Deutsche Industries Norm T05E.EPS Rated current 5 ma (code: /5 ma) Standard rated current is 2 ma. However, the 5 ma version has only class 0.5 (0.5 %) accuracy. OPTION (Category II) With Protection Tube or Thermowell (Refer to GS 6B2T2-E) Applied to model RN-4 and RN-5. Note: Calculate sheath length (symbol : L) from the equations below. RN L = protection tube or thermowell length (symbol: A) + nipple length + 25 mm RN L = protection tube or thermowell length (symbol: A) + nipple length + 35 mm All Rights Reserved. Copyright 1985, Yokogawa Electric Corporation GS 06B04D01-00E Mar. 01,

4 4 MODEL AND SUFFIX CODES Model Suffix Code Description RN RS (1) Construction (2) Terminal Style (Applied to Model RN) (2) Terminal Style (Applied to Model RS) (3) Sheath Outside Diameter (4) Lead Wire Length (5) Mounting (Rating) (6) Mounting (Nominal Size) (7) Classification of Element (8) Class N NN JH J J A A JT JF AT NP N A B C D E L M H S T U A B D E Resistance Temperature Sensors (with Terminal Box) Resistance Temperature Sensors (without Terminal Box) Plain Insertion Type Flange-mount Type (Applied to Model RN) Pipe Threads-mount Type Pipe Threads-mount Type with Nipple Coupler Spring Loaded Well Type with Nipple Coupler (* 1 ) General Type Terminal Box Phenol Resin Type Terminal Box Flameproof Type Terminal Box Double Element Type Terminal Box Lead WireType (Lead Wire (2 m) for General-Use) Connector Type Connector Type with Lead Wire (Lead Wire (2 m) for General Use) (Flameproof Type not available) Without Compensating Lead Wire (Except Model RS-16, -18, -36, -38) Expressed in 1-Digit Number (in m) (Applied to Model RS-16, -18, -36, -38) Without Mounting (Applied to Model RS-1 and RN-1) JIS 5 K Flange JIS 10 K Flange JIS 20 K Flange ANSI Class 150 Flange ANSI Class 300 Flange Tapered Threads for JIS Sized Pipe Straight Threads for JIS Sized Pipe Tapered Threads for ANSI Sized Pipe Nipple (Threads for JIS 1/2" Pipe) -Length: 100 mm Without Mounting (Applied to Model RS-1 and RN-1) 15 mm (1/2 in.) Flange 20 mm (3/4 in.) Flange 25 mm (1 in.) Flange 40 mm (1-1/2 in.) Flange 50 mm (2 in.) Flange (Applied to JIS 10 K Flange) 1/8 in. Pipe Threads (Applied to 1.0 to 4.8) 1/4 in. Pipe Threads 1/2 in. Pipe Threads 3/4 in. Pipe Threads 1 in. Pipe Threads JIS JPt100 for Low Temperature (-200 to 100 C) JIS JPt100 for Medium Temperature (0 to 350 C) JIS JPt100 for High Temperature (0 to 500 C) JIS, IEC Pt100 for Low Temperature (-200 to 100 C) JIS, IEC Pt100 for Medium Temperature (0 to 350 C) JIS, IEC Pt100 for High Temperature (0 to 500 C) Single Element, JIS Class B Single Element, JIS Class A Double Element, JIS Class B Double Element, JIS Class A (9) Sheath Length (L) Expressed in 4-Digit Numbers (in mm) - : L (Single Element) or D (Double Element) Nominal Resistance (Non-Standard) /PT JIS Pt. 50 (Standard Resistance: JIS Pt. 100 ) Flange Facing (Non-Standard) /FF Flat Face (Standard Flange Facing: Raised Face) Nipple Length (Non-Standard) Lead Wire Length (Non-Standard) Options (Category I) Options (Category II) /L /L /L /LEA /LEA /BN /BN /PAD-R..... /ST /WP-... /PG /AW /CF -... //WM //WH *1: (Applied only to Terminal Box Suffix 1 and 5 Type, and to Model RN) 50 mm 150 mm (Standard Length: 100 mm) 200 mm Heat Resistance (Standard Lead Wire: for General-Use) Heat Resistance Bayonet (without Holder) Bayonet (with Holder) Pad for Resistance Temperature Sensors Strap for Sheath-Fixing With Waterproof Cap With Flameproof Packing Adaptor With Allen Wrench (For Flameproof Type Terminal Box) Special Color Finish Drawn Protection Tube Drilled Thermowell T07E.EPS All Rights Reserved. Copyright 1985, Yokogawa Electric Corporation GS 06B04D01-00E Mar. 01,

5 5 DIMENSIONS RN-11 RN-21 RN-31 RN-41 RN-51 RS-16 All Rights Reserved. Copyright 1985, Yokogawa Electric Corporation GS 06B04D01-00E Jan. 07,

6 6 RS-17 RS-18 RS-36 RS-37 RS-38 When insertion length are less than the 0100 mm, accuracy cannot be guaranteed. < ORDERING INFORMATIONS > 1. Model and Suffix Codes 2. Insertion Length (Applied to model RS-3) 3. Option Desired All Rights Reserved. Copyright 1985, Yokogawa Electric Corporation Subject to change without notice GS 06B04D01-00E Jan. 07,

General Specifications

General Specifications General Specifications Models RM and RH Resistance Temperature Sensor GS 06B03B01-00E GENERAL Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

General Specifications

General Specifications General Specifications GS 1C2H1-E Model EJ11W, EJ11N and EJ11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium from entering directly

More information

General Specifications

General Specifications General Specifications Model EJB430 Gauge Pressure Transmitter GS 01C23E01-00E [Style: S2] The model EJB430 Gauge Pressure Transmitter can be used to measure liquid, gas, or steam pressure. It outputs

More information

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)... Page General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s High Temperature MgO Elements (RA).... Leadwire Style RTD s (RB).. Leadwire Style RTD s (RD, RE, RF, or RG

More information

General Specifications

General Specifications General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order

More information

General Specifications

General Specifications General Specifications DO0G Sensor for Dissolved Oxygen Analyzer GS 2J05D0-0E GENERA The DO0G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent

More information

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement

More information

General Specifications

General Specifications General Specifications DO30G Sensor for Dissolved Oxygen Analyzer GS 2J05D03-0E GENERA The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works,

More information

Thermocouples W A T L O W

Thermocouples W A T L O W W A T O W Watlow s mineral insulated thermocouples are fast-responding, durable, and capable of handling high temperatures. These thermocouples are manufactured with best-in-class XACTPAK, Watlow s trademark

More information

Hot Runner Thermocouples Model TC46

Hot Runner Thermocouples Model TC46 Electrical Temperature Measurement Hot Runner Thermocouples Model TC46 WIKA Data Sheet TE 65.46 Applications Plastics and rubber industry Hot Runner bushings, drops and nozzles Hot Runner manifolds Moulds

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

Pipe Temperature Sensor

Pipe Temperature Sensor -5429 Specifications/Instructions Pipe Temperature Sensor General Model TY783 is an immersion temperature sensor. Its Pt0 resistance (equivalent to JIS* C1604 Class ) output, in combination with a electronic

More information

Resistance Temperature Detectors (RTDs)

Resistance Temperature Detectors (RTDs) Website: Resistance Temperature Detectors (RTDs) Resistance Temperature Detectors (RTD's). These detectors are frequently used in the plastics industries and many others. Care must be taken to eliminate

More information

Hot runner thermocouple Model TC46

Hot runner thermocouple Model TC46 Electrical temperature measurement Hot runner thermocouple Model TC46 WIKA data sheet TE 65.46 for further approvals see page 7 Applications Plastics and rubber industry Hot runner bushings, drops and

More information

AccuTru Thermowells. Dedicated to those organizations that value improved temperature measurement for critical processes

AccuTru Thermowells. Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N O L O G I E S AccuTru Thermowells Dedicated to those organizations that value improved temperature measurement for critical processes Section 5 Index Thermowells Model Page PT-1

More information

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog) User s Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals by electronic

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

Mineral Insulated Resistance Thermometers (RTD)

Mineral Insulated Resistance Thermometers (RTD) Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types

More information

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector

More information

Electronic Temperature Sensor

Electronic Temperature Sensor Connection Head Type RTD or Element or RTD Cast Aluminum, Polypropylene or Stainless Steel Head Weather Proof Welded or Spring Loaded TDD TMD Hot Junction: Head Process Connection Conduit Connection 100Ω

More information

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751 ata Sheet 902210 Page 1/12 Mineral-Insulated RT Temperature Probe According to IN EN 60751 For temperatures from -50 (-200) to +600 C Flexible sheath cable with vibration-resistant measuring insert As

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced

More information

Section 3 Index Furnace Tube Skin Thermocouples

Section 3 Index Furnace Tube Skin Thermocouples Section 3 Index Furnace Tube Skin Thermocouples Thermocouple Assemblies Model Page O1 Bare End Terminations 3-1 O2 Lead Wire Extension 3-2 O3 SS Flex Armor Extension 3-3 O4 CGB Over SS Flex Armor 3-4 Thermocouple

More information

Direct immersion resistance thermometer

Direct immersion resistance thermometer Direct immersion resistance thermometer PLAIN STEM D100-101-102-103-160-162 CONFIGURATIONS General use RTD Product series PT100WT D100 D101 D102 D103 D160 D162 2 Features assembly The sensor can be immersed

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

General Specifications

General Specifications General Specifications Chemical Cleaning ph Measuring System GS B7A-E General Process ph measuring systems have played an important role in many fields including the chemical, food, metal, and paper pulp

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J5C2-E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up analyzers

More information

Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters Personal ph, ph/orp, Meters // Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/ Compact and lightweight 220g IP67 Waterproof CE,RCM,KC Various Convenient Data memory Alarm Clock Date/time

More information

Electric Top-Guided Single-Seated Control Valves

Electric Top-Guided Single-Seated Control Valves No. SS2-AGV200-0300 CV3000 Alphaplus series Electric Top-Guided Single-Seated Control Valves Model AGVB / AGVM OVERVIEW The CV3000 Alphaplus range of top-guided single-seat control valves features a compact

More information

Resistance thermometer with digital display Model TR75, battery operation

Resistance thermometer with digital display Model TR75, battery operation Electrical temperature measurement Resistance thermometer with digital display Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

Industrial Pt100 RTD's

Industrial Pt100 RTD's CA 2001 Resistance Welded process connection measuring insert. Can be Type CA 2001 CA 2003 Resistance Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert.

More information

MgO ORDER CODES. 1-1 Thermocouple Types CODE

MgO ORDER CODES. 1-1 Thermocouple Types CODE MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations A Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hardpacked standard

More information

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E. Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /

More information

Resistance thermometer with digital indicator Model TR75, battery operation

Resistance thermometer with digital indicator Model TR75, battery operation Electrical temperature measurement Resistance thermometer with digital indicator Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: Moore Industries - International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A. Electrical Apparatus: Flameproof Transmitter Enclosure Models LH2XSA and BHabcA Type of

More information

General Specifications

General Specifications General Specifications GS 12D06B01-01E ISC40 J Inductive Conductivity Sensors ISC40F J Holders and Adapters GENERAL The ISC40 J sensors are designed for use with the FLXA202/FLXA21 2-wire Analyzer, ISC202

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity

More information

AccuTru ExL Furnace Tubeskin Thermocouples

AccuTru ExL Furnace Tubeskin Thermocouples S E N S O R T E C H N O L O G I E S AccuTru ExL Furnace Tubeskin Thermocouples Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

General Specifications

General Specifications General Specifications EJA210E Flange Mounted Differential Pressure Transmitter The high performance flange mounted differential pressure transmitter EJA210E can be used to measure levels of densities

More information

Screw-in thermometer with connection lead Model TF37

Screw-in thermometer with connection lead Model TF37 Electrical temperature measurement Screw-in thermometer with connection lead Model TF37 WIKA data sheet TE 67.12 Applications Mobile hydraulics Machine building Compressors Automotive Cooling, heating,

More information

Article on Sheath materials, Thermowells, Fittings, and Terminations

Article on Sheath materials, Thermowells, Fittings, and Terminations Article on Sheath materials, Thermowells, Fittings, and Terminations 1. INTRODUCTION Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or

More information

General Specifications

General Specifications General Specifications Model -FTS Differential ph/orp-sensor Overview The -FTS is the newest development in ph sensor technology available from Yokogawa. This sensor combines the measuring technology of

More information

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/

RTD Assembly TH15. Compact Instructions. KA195R/24/ae/ RTD Assembly TH15 Compact Instructions Measuring System RTD assembly TH15 with spring loaded insert. The Pt100 RTD is specifically designed for use in two different process temperature ranges (low range

More information

ph (ORP) SENSOR ASSEMBLY

ph (ORP) SENSOR ASSEMBLY Specifications Sheet No.SPEC-3109E (3rd Edition) SP ph (ORP) SENSOR ASSEMBLY SPECIFICATIONS Flow-Through Type Probe Electrode holder for pipe line or sampling method Model SP3101 SP3111 Process connection

More information

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E. Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter MASSMAX Series Straight twin tube Coriolis Mass Flowmeter OUTLINE MASSMAX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance.

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX The MPX Series Magnetostrictive Level sensor provides highly accurate and repeatable level readings in a wide variety of liquid

More information

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement TE 65.01 Thermocouples Measuring Insert Electronic Temperature Measurement rigid Model TC 001 flexible Model TC 002 Services intended Exchangeable measuring insert for all industrial and laboratory applications.

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. Industrial Temperature Assemblies measuring monitoring analysing MWD OO Meassuring range -200...+600ºC. OO Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. OO Output: Resistance or analogue

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening SPATTER-GUARDED SWITCHES Model LS Effective countermeasures against the adhesion of spatter. UL/CSA/GB(CCC marking)-approved. (excluding some models) ORDER GUIDE Actuator Name Roller lever type Shape Max.

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

General Specifications

General Specifications General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the differential

More information

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments

More information

C07 - Probes. Sonde EN Pg.01/ E.M.P. Srl -ITALY -

C07 - Probes. Sonde EN Pg.01/ E.M.P. Srl -ITALY - C07 - Probes Sonde EN Pg.01/12 2011-01 E.M.P. Srl -ITALY - www.emp.it C07 - Probes S MgO Insulation S100851000J J insulated 1,0 80 1000 S101051000J J insulated 1,0 100 1000 S102051000J J insulated 1,0

More information

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications

More information

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB Electrical temperature measurement For the plastics machinery industry Fixed bayonet Model TC47-FB WIKA data sheet TE 67.24 Applications Plastics and rubber industry For direct installation into the process

More information

ZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS

ZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS ZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS TRADE CATALOGUE 2005 ZEAL The genuine article since 1888 Distributer : ANSARI AGENCIES SDN.BHD. 18-A, 1st Floor, Jalan MJ/ 7, Medan Maju Jaya,

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor /T, HF-resistant

More information

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments

More information

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid Metal free, port solenoid valve for chemical liquid MY/MYG Series NC (normally closed) type, universal type Working fluid: water, pure water, chemical liquids Port size: M JIS symbol MY ( port) : NC (normally

More information

Resistance thermometer Model TR10-E, for additional thermowell

Resistance thermometer Model TR10-E, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry

More information

OM004, OM006 & OM008 Oval Gear Meter

OM004, OM006 & OM008 Oval Gear Meter OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small

More information

Top-Guided Single Seated Control Valves (Rating : ANSI 600 or Less)

Top-Guided Single Seated Control Valves (Rating : ANSI 600 or Less) No. SS2-8-0 Top-Guided Single Seated Control Valves (Rating : ANSI 0 or Less) OVERVIEW Model VST control valves are suitable for use in fluid with slurry because of its one side guiding construction. Guide

More information

RAPID SHIP SENSORS, STOCK WIRE

RAPID SHIP SENSORS, STOCK WIRE W A T L O W RAPID SHIP SENSORS, STOCK WIRE AND CONNECTORS ISO 900 : 2000 Registered Company Richmond, Illinois USA 2005 New Rapid Ship Program Responds to Your Immediate Sensing Needs Capabilities Watlow

More information

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product Series TCM Multipoint Thermocouple Assemblies Multipoint Thermocouples are used in a broad range of processes and installations to monitor the temperature in multiple positions or elevations. These sensors

More information

Temperature Indicating Controller

Temperature Indicating Controller \ KF Series Temperature Indicating Controller Model KFT OVERVIEW The KF Series instruments are field-installed type of pneumatic indicating controllers which are used to measure and control the various

More information

Model OR8ERG KCl Refillable type ORP Sensor

Model OR8ERG KCl Refillable type ORP Sensor User s Manual Model OR8ERG KCl Refillable type ORP Sensor R 4th Edition Blank Page INTRODUCTION This manual covers the OR8ERG KCl Refillable type ORP Sensor. Other related items are described in the following

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

Explosion proof RTD assembly T15

Explosion proof RTD assembly T15 Explosion proof RTD assembly T15 Compact Instructions Measuring System Explosion proof RTD assembly with spring loaded insert and enclosure for process industry. The Pt100 RTD is specifically designed

More information

Model PH8HF, PH8HFF Flow-Through Type Holder

Model PH8HF, PH8HFF Flow-Through Type Holder User s Manual Model PH8HF, PH8HFF Flow-Through Type Holder 5th Edition INTRODUCTION This manual covers the PH8HF, PH8HFF Flow-Through Type Holder. Other related items are described in the

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

RTD and Thermocouple Assemblies Reference Manual

RTD and Thermocouple Assemblies Reference Manual RTD and Thermocouple Assemblies Reference Manual www.rosemount.com RTD and Thermocouple Mounting and Installation Advice for Resistance Thermometers and Thermocouple Assemblies NOTICE Read this manual

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Technical Information Omnigrad TST90, TET90

Technical Information Omnigrad TST90, TET90 TI01109T/09/EN/02.13 71214205 Products Solutions Services Technical Information Resistance thermometer and insert for thermal energy measurement High-precision measurement of temperature differences with

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

STK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube

STK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local

More information

General Specifications

General Specifications eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial

More information

ORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired.

ORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired. MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB Electrical temperature measurement For the plastics machinery industry Adjustable bayonet Model TC47-AB WIKA data sheet TE 67.20 Applications Plastics and rubber industry For direct installation into the

More information

General Specifications

General Specifications General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the differential

More information

SPECIFICATION SHEET. ±1%, ±5%, Convex Type General purpose chip resistors array

SPECIFICATION SHEET. ±1%, ±5%, Convex Type General purpose chip resistors array SPECIFICATION SHEET CNA24, CNA34 ±1%, ±5%, Convex Type General purpose chip resistors array Size 0402x4, 0603x4 (8p4R) ( Automotive & Anti-sulfur ) All data in this sheet are subject to change, modify

More information

Thermocouple insert for Temperatur Sensor omniset- TPC 100

Thermocouple insert for Temperatur Sensor omniset- TPC 100 Technical Information TI 278T/02/en 60022421 Thermocouple insert for Temperatur Sensor omniset TPC 100 Thermocouple mineral insulated insert PCP (4...20 ma), HART or PROFIBUSPA electronics The TPC 100

More information

Operating Instructions TF04

Operating Instructions TF04 10 Brent Drive Hudson, MA 01749 Tel: +1-978-212-0006 Fax: +1-978-568-0060 Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating Instructions TF04 Temperature

More information

DIGI-TEL THERMOMETERS

DIGI-TEL THERMOMETERS TEL-TRU MANUFACTURING COMPANY DIGI-TEL THERMOMETERS www.teltru.com ELECTRONIC DIGITAL THERMOMETERS Tel-Tru s DIGI-TEL Thermometers combine the easy, quick visual reference feature of a local indicator

More information

ORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN -

ORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN - MgO Insulated Thermocouples with Extension Leadwire MgO Insulated Thermocouples with Sheath Terminations Pyromation MgO thermocouple assembly consists of a thermocouple element swaged in hard-packed, standard-purity

More information

RTD PT100 Insert With Solid Drilled Flanged Thermowell

RTD PT100 Insert With Solid Drilled Flanged Thermowell RTD PT100 Insert With Solid Drilled Flanged Thermowell Product Data Sheet RTINTWFL 2017 rev1.00 Full temperature sensor & thermowell assemblies. Consisting of a temperature sensing element housed in a

More information

Food, Dairy and Pharmaceutical

Food, Dairy and Pharmaceutical CP Sanitary Fitting Reference Data Sheet he CP (clean in place) sanitary connections illustrated on this page are the most commonly used fittings in food, dairy, beverage, pharmaceutical, and chemical

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor PH4P/PH4PT,

More information

General Specifications

General Specifications General Specifications EJA118E Diaphragm Sealed Differential Pressure Transmitter [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the

More information

GLASS INDUSTRIAL THERMOMETERS

GLASS INDUSTRIAL THERMOMETERS TEL-TRU MANUFACTURING COMPANY GLASS INDUSTRIAL THERMOMETERS World -Class Thermometers Since 1916 www.teltru.com Glass Industrial Thermometers Tel-Tru Glass Industrial Thermometers are used on pipelines

More information