Quick Start Guide for Installation and Setup. IQ SENSOR NET System 184 XT

Size: px
Start display at page:

Download "Quick Start Guide for Installation and Setup. IQ SENSOR NET System 184 XT"

Transcription

1 for Installation and Setup IQ SENSOR NET System 184 XT ba75479e01 07/2005

2 IQ SENSOR NET System 184 XT IQ SENSOR NET 1. Accessories and Tools for Installation...p Connecting the System Components...p. 5 Joining MIQ modules ("stack mounting")... p. 5 Linking modules via cable ("distributed mounting")... p. 9 Connecting sensors... p. 11 Mounting the MIQ/C184 XT... p. 13 Connecting the power supply to the line power... p Setting the Terminator Switches...p Powering Up...p Basic Settings...p. 19 2

3 IQ SENSOR NET System 184 XT 1 Accessories and Tools for Installation Accessories: Contact base with plastic tapping screws (in the scope of delivery of each MIQ module) M4 ISO blind nut (in the scope of delivery of each MIQ module) M4x16 cheese-head screw with plastic washer (in the scope of delivery of each MIQ module) Cable gland with seal (in the scope of delivery of each MIQ module) SACIQ sensor connection cable SNCIQ Cable or SNCIQ/UG earth cable. These cables are only required if you want to connect MIQ modules that are located at different sites. SSH/IQ sun shield MR/SD 170 assembly set for rail mounting of sun shield SSH/IQ 3

4 IQ SENSOR NET System 184 XT Tools required: Phillips screw driver (size 5) Screw driver (size 3) The following tools are only required if you want to connect MIQ modules that are located at different sites with the aid of the SNCIQ or SNCIQ/UG cable: Cable stripping knife Wire stripper Wire end sleeves for 0.75 mm 2 wire cross-section with matching crimping tool The following tools are only required if you want to mount an MIQ module to a wall: Drilling machine with an 8 mm drill bit (select the drill bit type appropriate for the wall material) 4

5 IQ SENSOR NET System 184 XT 2 Connecting the System Components Joining MIQ modules ("stack mounting") Caution Observe the following rules for safe operation: Do not mount more than three modules to form a stack. Do not mount more than one power supply module in a module stack. If possible, select the MIQ power supply module to be the rearmost module in the stack. Always mount the MIQ modules in an upright position (to avoid retained humidity) Protect MIQ modules installed outside against the effects of the weather (snow, ice and direct sun light) by a sun shield. Procedure: Note The steps 2 to 8 describe the mounting of the rearmost module to a vertical rail using the SSH/IQ sun shield. If you mount the module in a different way, continue with step 10. Sun shield SSH/IQ + assembly set MR/SD 170: Pre-assemble each of the four hexagon head bolts (2) with a nut (3) and a lock washer (4) to a clamping device (1). All parts are contained in the scope of the MR/SD Mount the sun shield SSH/IQ to the clamping device using the cap screws (5) and washers (6) SSH/IQ MR/SD 170 5

6 IQ SENSOR NET System 184 XT 7 8 SSH/IQ 3 Position both clamping devices at the rail and fix them using the four nuts (7) and the four lock washers (8). The parts are contained in the scope of the MR/SD 170. Rail MR/SD Select the module that is to be the rearmost module of the stack. If possible, select the power supply module for this. Rearmost MIQ module in the stack: 9 5 Remove both covers (9) on the back. 6 Remove the two screws on the left side (10) and open the lid. Bei Stapelmontage Aufkleber entfernen und Kontaktträger montieren For stack mounting remove label and install contact carrier Insert the two cheese head screws with the white plastic washers (11) into the drilled mounting holes. 8 Loosely screw the ISO blind nuts (12) on the cheese head screws from the back. Do not yet tighten the screws! 11 6

7 IQ SENSOR NET System 184 XT 9 Position the module on the sun shield and fix it into place by tightening the cheese head screws (11). To mount further modules on the lid, continue with the following steps: Close the lid and fix it using the two screws (10). 11 Remove the two covers (13) on the front. 12 Remove the contact cover (14) from the contacts. Do not remove the contact cover completely but leave it connected to the side of the module Next MIQ module in the stack: Select the next module to be connected to the lid of the existing module. On this module: 14 Remove the two covers (15) on the back. 15 Pull off the label (16) on the back. 16 Remove the two screws on the left side (17). 16 Bei Stapelmontage Aufkleber entfernen und Kontaktträger montieren For stack mounting remove label and install contact carrier 17 7

8 IQ SENSOR NET System 184 XT 17 Using the two screws provided (19), fix the contact base (18) to the module back. 18 Open the lid Insert the two cheese head screws (20) with the white plastic washers (21) in the drilled mounting holes. 20 Loosely screw the ISO blind nuts (22) on the cheese head screws from the back. Do not yet tighten the screws! Connecting both MIQ modules: 21 Attach the prepared module with the lid open to the back module. At the front module, there are two clips at the lower back edge. First insert these clips in the slots on the lid of the back module. Then insert the two blind nuts of the front module in the drilled mounting holes on the lid of the back module. 22 Slightly press both modules against each other and tighten the two cheese head screws at the front module. 23 Close the lid of the front module and fix it using the two screws (17). To mount a further module on the stack repeat the steps 8 to 23. Note that a maximum of three modules may be mounted as a stack. 17 8

9 IQ SENSOR NET System 184 XT Linking modules via cable ("distributed mounting") Procedure: 1 Run the cable between the modules to be interconnected. Run the cable ends to the bottom of the module housings. 2 Cut the cable to the appropriate length. Take into account that the cable ends must intrude min. 3 cm into the housing for proper connection. Cable ends ready for connection to the module: approx. 45 mm red SNCIQ green approx. 35 mm approx. 45 mm 3 Prepare both cable ends: SNCIQ: Using a cable stripping knife remove approx. 45 mm of the cable sheath. SNCIQ/UG: Using a cable stripping knife remove approx. 45 mm of the outer and inner cable sheath. Then remove another 35 mm of the outer cable sheath. Shorten the shielding braid up to the end of the cable sheath. Shorten the two plastic fillers up to the end of the cable sheath. Using a wire stripper bare the red and green wires and fit them with wire end sleeves. Fit the stranded wire with a wire end sleeve. SNCIQ/UG Note You can use any free SENSORNET connection port for interconnecting MIQ modules. Make sure that the connection port is designated with "SENSORNET". A label with all terminal designations is located on the module floor. Each module has two SENSORNET ports in the right-hand section of the terminal strip. Some modules may have further SENSORNET ports in the left-hand section. 9

10 GREEN GRÜN SHIELD SCHIRM RED ROT IQ SENSOR NET System 184 XT SENSORNET 2 label with terminal designations SENSORNET SNCIQ or SNCIQ/UG On both modules: 4 Open the lid. Inside you see the terminal strip (green) located in the lower section of the module. The label with all terminal designations is located on the module floor. 5 Select a free SENSORNET connection port. 6 Unscrew the blanking cover underneath the SENSORNET connection port. 7 Screw the cable gland (1) into the opening. Prior to this, put the sealing ring (2) over the thread of the cable gland. 8 Loosen the coupling ring (3) and thread the cable through the cable gland into the housing. The end of the cable sheath should be flush with the inner end of the cable gland. 9 Tighten the coupling ring (3). Example: connection on "SENSORNET 1" port: terminal designation: X3 X2 X1 SENSORNET 1 red shield green 10 Connect the wires to the SENSORNET connection port. To do so, loosen the screw at the corresponding screw connection, insert the wire into the screw connection, and tighten the screw again. Observe the designation of the connection port on the label. It must read: SENSORNET 1 (2, 3, 4): RED SHIELD (= stranded wire, not insulated) GREEN 11 When all three wires are properly connected, close the lid of the module. SNCIQ or SNCIQ/UG 10

11 IQ SENSOR NET System 184 XT Connecting sensors Procedure: 1 Run the cable between the sensor and the connection module. Run the cable end with the open wires to the bottom of the module housing. Take into account that the wire ends must intrude min. 3 cm into the housing for proper connection. Note You can use any free SENSORNET connection port for connecting a sensor. Make sure that the connection port is designated with "SENSORNET". A label with all terminal designations is located on the module floor. Each module has two SENSORNET ports in the right-hand section of the terminal strip. Some modules may have further SENSORNET ports in the left-hand section. SENSORNET 2 label with terminal designations SENSORNET SACIQ On the connection module: 2 Open the lid. Inside you see the terminal strip (green) located in the lower section of the module. The label with all terminal designations is located on the module floor. 3 Select a free SENSORNET connection port. 4 Unscrew the blanking cover underneath the SENSORNET connection port. 5 Screw the cable gland (1) into the opening. Prior to this, put the sealing ring (2) over the thread of the cable gland. 6 Loosen the coupling ring (3) and thread the sensor connection cable through the cable gland into the housing. The heat shrink tube at the end of the cable sheath should be flush with the inner end of the cable gland. 7 Tighten the coupling ring (3). 11

12 GREEN GRÜN SHIELD SCHIRM RED ROT IQ SENSOR NET System 184 XT Example: connection on "SENSORNET 1" port: terminal designation: X3 X2 X1 SENSORNET 1 red black green 8 Connect the wires to the SENSORNET connection port. To do so, loosen the screw at the corresponding screw connection, insert the wire into the screw connection, and tighten the screw again. Observe the designation of the connection port on the label. It must read: SENSORNET 1 (2, 3, 4): RED SHIELD (= stranded wire, not insulated) GREEN 9 When all three wires are properly connected, close the lid of the module. SACIQ On the sensor: 10 Remove the protective caps from the plug connection of the sensor and the SACIQ cable. SACIQ 5 11 Align the socket of the cable with the plug head connector of the sensor. Rotate the socket so that the pin (4) is in line with either of the two small holes in the socket (5). 12 Then push the socket onto the connector and rotate the coupling ring (6) clockwise until stop

13 IQ SENSOR NET System 184 XT Mounting the MIQ/C184 XT Procedure: On the lid of any free module: 1 Remove the contact cover (1) from the contacts. Do not remove the contact cover completely but leave it connected to the side of the module Attach the MIQ/C184 XT to the module lid. To do so, insert the flap on the back of the MIQ/C184 XT into the slot on the door hinge of the module. Then, pull back the lever (2), place the MIQ/C184 XT completely on the module and release the lever. 3 To protect the MIQ/C184 XT from being inadvertently removed, fix the lever with the aid of the screw (3). The screw is contained in the scope of delivery of the MIQ/C184 XT. MIQ/C184 XT Top view: Pull lever back Note The mobile terminal MIQ/T 2020 (PLUS) is mounted in the same way except for step 3. The mobile terminal is not intended to be fixed by a fixing screw. 13

14 IQ SENSOR NET System 184 XT Connecting the power supply to the power line ( VAC: MIQ/PS power supply module; 24 V AC/DC: MIQ/24V power supply module) Warning If the power supply is connected incorrectly, it may represent a danger to life from electric shock. Pay attention to the following points during installation: The MIQ/PS or MIQ/24V power supply module may only be connected to the power supply by a trained electrician. The connection of the MIQ/PS or MIQ/24V power supply module to the power supply may only be carried out when it is not carrying any voltage. The power supply must fulfill the specifications given on the nameplate and in the operating manual of the power supply module. A switch or power switch must be provided as a disconnecting device for the power supply module. The disconnecting device must be installed in the vicinity of the power supply module, easily accessible by the user, and identified as a disconnecting device for the power supply module. After it has been installed, the power supply module may only be opened if the line voltage has been switched off beforehand. Procedure: 1 Run the line cord to the power supply module. Run the cord end to the bottom of the module housings. 2 Cut the line cord to the appropriate length. Take into account that the cord end must intrude min. 3 cm into the housing for proper connection. Line cord end ready for connection: 3 Prepare the end of the line cord: Using a cable stripping knife remove approx. 45 mm of the cable sheath. Using a wire stripper bare the wires of phases L and N and fit them with wire end sleeves. If present, cut off the protective earth conductor wire at the end of the cable sheath. 14

15 IQ SENSOR NET System 184 XT On the power supply module: 4 Open the lid. Inside you see the terminal strip (green) located in the lower section of the module. The leftmost connection port is the line power connection. 5 Unscrew the blanking cover underneath the leftmost connection port. 6 Screw the cable gland (1) into the opening. Prior to this, put the sealing ring (2) over the thread of the cable gland. 7 Loosen the coupling ring (3) and thread the line cord through the cable gland into the housing. The end of the cable sheath should be flush with the inner end of the cable gland. 8 Tighten the coupling ring (3). 9 Connect the wires of the line cord to the line power connection port. To do so, loosen the screw at the corresponding screw connection, insert the wire into the screw connection, and tighten the screw again. MIQ/PS: Observe the designation of the connection on the label. Connect the wires as follows: X10: N X11: L MIQ/24V: Connect the wires. It is not important which wire is connected to which terminal. 10 When both wires are properly connected, close the lid of the module. 15

16 GREEN GRÜN SHIELD SCHIRM RED ROT SN TERMINATOR GREEN GRÜN SHIELD SCHIRM RED ROT IQ SENSOR NET System 184 XT 3 Setting the Terminator Switches Note For failure-free operation, the SN terminator switches (terminating resistors) must be set to ON on precisely two specific MIQ modules in the IQ SENSOR NET. The switches are located in each MIQ module between the two SENSORNET connections on the right of the terminal strip. The switch is designated "SN TERMINATOR": SN Terminator Switch ON OFF X6 X5 X4 ON EIN X3 X2 X1 SENSORNET 2 OFF AUS SENSORNET 1 For checking and setting the switch, open the module, set the switch to the required position and close the module again. How to select the right switches: Follow the rules given below for setting the SN terminator switch: 1 If the system contains only one stack of MIQ modules, the SN terminator switch on the foremost and rearmost MIQ modules must be set to ON. 2 If the system contains branched installed MIQ modules, the SN terminator switches at the start and at the end of the longest continuous cable length must be set to ON. 3 In all other MIQ modules, the SN terminator switch must be set to OFF. 16

17 IQ SENSOR NET System 184 XT The following sketches gives you examples of where to set the switches to ON: x x x x = MIQ module with the SN terminator switch set to ON = MIQ module with the SN terminator switch set to OFF = Module stack x 17

18 IQ SENSOR NET System 184 XT 4 Powering Up For powering up, switch on the voltage supply of the MIQ power supply module. The system starts with the following start-up sequence: Start-up sequence: 1 In the initial start phase, all IQ SENSOR NET components are automatically registered on the MIQ/C184 XT controller module and the terminal is initialized. Then, the system performs a self test. This process may last a few seconds. 2 As soon as the terminal is successfully initialized, the measured value display appears (fourfold display). In the case of IQ sensors that are not yet providing measured values, "Init" appears temporarily. 3 When the start-up sequence is finished, the measured values of all sensors appear on the display. The system is now ready for measuring. 18

19 IQ SENSOR NET System 184 XT 5 Basic Settings Selecting the display language By default, the display language of the IQ SENSOR NET is German. To select another language, proceed as follows: Procedure: 1 In the measurement screen, press s. The Einstellungen/Settings menu comes up. The first menu item, Sprache/Language, is highlighted. If not, turn the rotary switch until Sprache/Language is highlighted. 2 Press g. The Sprache/Language menu comes up with a list of all available languages. 3 Highlight your language in the list by turning the rotary switch. Then press g. The checkmark to the right indicates that the language is set. 4 Press m to return to the measurement screen. The system will work with the new language. 19

20 IQ SENSOR NET System 184 XT Assigning user-defined names to sensors The IQ SENSOR NET enables you to assign user-defined names to all sensors. The name appears with the measured value on the measurement screen. The sensor name may consist of up to 11 characters. By default, the sensor name is identical with the serial number of the sensor. Procedure: 1 In the measurement screen, press s. The Settings/Einstellungen menu comes up. 2 Highlight the menu item Edit list of sensors by turning the rotary switch. 3 Press g. The Edit list of sensors menu comes up. 4 Highlight the Sensor name column by turning the rotary switch. 5 Press g. 6 Highlight the required sensor by turning the rotary switch. 20

21 IQ SENSOR NET System 184 XT 7 Press g. You are now in the edit mode for the sensor name. Note: Whenever the p symbol is shown as last character, pressing g will terminate the edit mode. All entries made so far will be adopted. If you want to abort the whole procedure and keep the original sensor name, press e. 8 Turn the rotary switch left or right to select the first character. The following characters are available: a... z A... Z µ % & / ( ) + - = > <.!? _ 9 Press g. Now you can select the next character. 10 Repeat the steps 8 and 9 accordingly until the name is complete. Note: If you want to delete the last character, select the left arrow symbol (b) and press g. 11 When the name is complete and the last character is the p symbol, press g. The edit mode is terminated. The new sensor name is adopted. 12 Press m to return to the measurement screen. The new name appears with the measured value. 21

22 IQ SENSOR NET System 184 XT 22

OPERATING MANUAL. ba75998e05 03/2015. P 700 IQ Analyzer MEASURING SYSTEM FOR ONLINE DETERMINATION OF ORTHOPHOSHATE IN AQUEOUS SAMPLES

OPERATING MANUAL. ba75998e05 03/2015. P 700 IQ Analyzer MEASURING SYSTEM FOR ONLINE DETERMINATION OF ORTHOPHOSHATE IN AQUEOUS SAMPLES OPERATING MANUAL ba75998e05 03/2015 P 700 IQ Analyzer MEASURING SYSTEM FOR ONLINE DETERMINATION OF ORTHOPHOSHATE IN AQUEOUS SAMPLES P700IQ The latest version of the present operating manual is available

More information

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool 57-1 Front door Tools Special tools and equipment T 10011 Socket 3320/2 Bit insert for 3320 3410 Socket T 10034 Assembly tool 57-2 Front door, assembly overview Note: The instrument panel must be removed

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

Pneumatic Rotary Actuator Type 3278

Pneumatic Rotary Actuator Type 3278 Pneumatic Rotary Actuator Type 3278 Fig. 1 Type 3278 Pneumatic Rotary Actuator 1. Design and principle of operation The single-acting rotary actuator incorporating spring return mechanism can be attached

More information

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

Installation Manual TWM Performance Short Shift Kit Stage 1 and Stage 2 MazdaSpeed 6

Installation Manual TWM Performance Short Shift Kit Stage 1 and Stage 2 MazdaSpeed 6 Page 1 Installation Manual TWM Performance Short Shift Kit Stage 1 and Stage 2 MazdaSpeed 6 Please Note: It is preferable to park on a flat surface, as you will have to engage and disengage the hand brake

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual 3143 Production DriveFairfeild, Ohio 45014513-874-3733 Model HA-45 Installation and Service Manual 3143 Production DriveFairfeild, Ohio 45014513-874-3733 Model HA-45 Installation and Service Manual Table

More information

Operating Instructions (Translation)

Operating Instructions (Translation) Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In

More information

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER Table of Contents Page Tools Needed (A) 3 Replacement

More information

Method. Remote solenoids. QuickInstall Guide

Method. Remote solenoids. QuickInstall Guide Remote solenoids Where remote solenoids are specified a single supply pipe is taken from the pump, or tap supply and connected to a single entry point on the remote solenoid manifold. From each solenoid

More information

GENERAL SAFETY... 3 PARTS LIST...

GENERAL SAFETY... 3 PARTS LIST... Rev 17a 1 GENERAL SAFETY... 3 PARTS LIST... 4 GTR100... 4 GTR058... 5 TECHNICAL SPECIFICATIONS... 6 FEATURES:... 6 QUICK INSTALLATION GUIDE... 7 GATE ARM INSTALLATION... 8 BEFORE YOU START... 8 INSTALLATION

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

Aopec Dual Battery Kit Fitting Instructions

Aopec Dual Battery Kit Fitting Instructions AOPEC USA LLC. 1911 US Hwy 301 Suite 460 Tampa, FL 33619 Tel: 813-450-2156 Fax: 813-450-2638 www.aopec.com Aopec Dual Battery Kit Fitting Instructions Aopec Dual Battery Kit Fitting Instructions Fitment

More information

FACTORY AUTOMATION MANUAL ENI11HD

FACTORY AUTOMATION MANUAL ENI11HD FACTORY AUTOMATION MANUAL ENI11HD Heavy-Duty Incremental Rotary Encoder With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for

More information

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Pneumatic or Electropneumatic Positioner for Rotary Actuators Type 3761 Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition June 2004 Contents Contents Page 1 Design and

More information

Pneumatic Control Valve Assembly Type 3331/3278

Pneumatic Control Valve Assembly Type 3331/3278 Pneumatic Control Valve Assembly Type 3331/3278 Fig. 1 Type 3331/3278 Pneumatic Control Valve Assembly 1. Design and principle of operation The pneumatic control valve assembly consists of a Type 3331

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

TIDALFLUX 2300 F Quick Start

TIDALFLUX 2300 F Quick Start Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS

More information

BROOKS STAIRLIFTS SUPERGLIDE 120

BROOKS STAIRLIFTS SUPERGLIDE 120 BROOKS STAIRLIFTS SUPERGLIDE 120 INSTALLATION PROCEDURES CONTENTS Health And Safety Hazards 3 Unpacking the Stairlift Carriage 4 Pre-Installation Procedure 5 Box Contents 6 Installation Tools 9 1.1 Required

More information

Materials List: Tools List:

Materials List: Tools List: Materials List: Anchor assembly Automated power supply Automated power supply hardware packet Automation bracket assembly Automation bracket assembly hardware packet Automation winch assembly Cable Cable

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

OpenEV. OpenEVSE 40A Charging Station. Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit.

OpenEV. OpenEVSE 40A Charging Station. Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit. OpenEV OpenEVSE 40A Charging Station Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit. Written By: Christopher Howell 2017 openevse.dozuki.com/ Page 1 of 13 INTRODUCTION

More information

PV Inverter SUNNY BOY 3300/3800

PV Inverter SUNNY BOY 3300/3800 PV Inverter SUNNY BOY 3300/3800 Installation Manual SB33-38-11-IA-en-62 IMEN-SB33-38-11 Version 6.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Manual.........................

More information

Disassembly. 1 Pull off the QUIK-LOK cable from the machine.

Disassembly. 1 Pull off the QUIK-LOK cable from the machine. Special Tools Require Important! Torx TX0 bit 0 0 Screwdriver Torx 0 0 0 Forcing Discs 0 Before beginning the maintenance work, perform an initial check with a high voltage test according to VDE (see chapter

More information

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual

More information

MFS/MFD HY-TRAX Installation Guide

MFS/MFD HY-TRAX Installation Guide 8 MFS/MFD HY-TRAX Installation Guide L-4534 MFD HY-TRAX An ISO 9001:2008 Certified Company 580 West Park Road Leetsdale, PA 15056 ph. 724.318.1100 fax 724.318.1200 www.schroederindustries.com L-4534 MFS/MFD

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Model No. Description HR3200C, HR3210C, HR3210FCT Rotary Hammer 32mm (1-1/4") CONCEPT AND MAIN APPLICATIONS HR3200C series models have been developed as successor models of HR3000C,

More information

Installation Instructions - D-Series Warming Cabinet Instruction Door for Hinge UseReversal (Glass and Stainless Steel Doors)

Installation Instructions - D-Series Warming Cabinet Instruction Door for Hinge UseReversal (Glass and Stainless Steel Doors) Header Cam Lock Reversal... pg 1-4 Glass Door hinge reversal..... pg 5-9 Steel Door hinge reversal..... pg 10-13 Remove Panels Before reversing door hinges, the Header Cam Lock assembly must be reversed.

More information

1 GENERAL INFORMATION

1 GENERAL INFORMATION Broadcast and Entertainment Products ProAx Triaxial Camera Connectors Installation Instructions Content Page 1 GENERAL INFORMATION... 2 1.1 Standard Tools... 3 1.2 ADC ProAx Triaxial Cable Strip Gauge...

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

COLD AIR INTAKE INSTALLATION INSTRUCTIONS. # D Fits: F10 M5 # D Fits: F06/F12/F13 M6 PARTS LIST

COLD AIR INTAKE INSTALLATION INSTRUCTIONS. # D Fits: F10 M5 # D Fits: F06/F12/F13 M6 PARTS LIST COLD AIR INTAKE INSTALLATION INSTRUCTIONS # D760-0035 Fits: 2013-15 F10 M5 # D760-0037 Fits: 2012-15 F06/F12/F13 M6 PARTS LIST (1) Left Carbon Airbox Lid (1) Right Carbon Airbox Lid (1) Left Carbon Snorkel

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Accessory Application Publications No. BII 31129 REARVIEW CAMERA 2006 RL Issue Date OCT 2005 PARTS LIST Attachment Kit P/N: 08B21-SJA-B00 Template Rear camera trim 6-Pin connector

More information

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions QS Rule Raritan PX Power Cord Installation Guide This installation guide explains how to install power cords on Raritan PX products that do not come with a factory installed power cord. This type of product,

More information

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP BALL VALVES TABLE OF CONTENTS MAINTENANCE AND INSTALLATION INSTRUCTIONS 1. 2. 2.1 2.2 2.3 2.4 GENERAL...Page 1 HANDLING...1 Receiving and Storing...1

More information

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size Dominion PX Quick Setup Guide Thank you for purchasing the Dominion PX intelligent power distribution unit (PDU). The intended use of the Raritan Dominion PX is distribution of power to information technology

More information

American Standard ProAx Triaxial Camera Connectors Installation Instructions

American Standard ProAx Triaxial Camera Connectors Installation Instructions American Standard ProAx Triaxial Camera Connectors Installation Instructions Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................

More information

C Power Connection Kit

C Power Connection Kit 1548-4000C Power Connection Kit For use with Dekoron 2700 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4000C electrical connection kit distirbuted by Heat-Line is

More information

#TL T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS

#TL T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS #TL100069 2.0T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS Notes: These instructions were written for a North American specification MkVII GTI. Other models, like the Golf R, are similar. When

More information

TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK INSTALLATION MANUAL SADDLE BOX STARTER KIT. Model: QDSKSA01. Part No.

TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK INSTALLATION MANUAL SADDLE BOX STARTER KIT. Model: QDSKSA01. Part No. TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK INSTALLATION MANUAL SADDLE BOX STARTER KIT Model: QDSKSA01 Part No. 24-0326 Rev. A ECN 5430 ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

INSTALL INSTRUCTIONS

INSTALL INSTRUCTIONS INSTALL INSTRUCTIONS Models: 6005 & 6005TK (For Non Electric Mirrors) GM CK Body Style If your stock mirrors are stock electric the wrong set has been ordered. Do not attempt to manually extend or retract

More information

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478 Supplementary instructions Mounting accessories, pressure measurement technology Document ID: 78 Contents Contents About this document.... Function.... Target group.... Symbols used... For your safety....

More information

Pressure Reducing Valve Type 2114/2415

Pressure Reducing Valve Type 2114/2415 Pressure Reducing Valve Type 2114/2415 Fig. 1 Type 2114/2415 1. Design and principle of operation The Type 2114/2415 Pressure Reducing Valve consists of the Type 2114 Valve and the Type 2415 Actuator.

More information

LABOUR ESTIMATE GUIDE

LABOUR ESTIMATE GUIDE INSTALLATION INSTRUCTIONS FOR 2003-Current Audi S4 (B6 & B7) Includes Sedan, Avant, & Cabriolet These instructions are applicable to vehicles equipped with either manual or automatic tiptronic transmissions

More information

CAUTION. INSTALLATION INSTRUCTIONS Part Number Hidden Winch Kit with special XD 9000 Short Drum Winch For Ford F-150 Truck

CAUTION. INSTALLATION INSTRUCTIONS Part Number Hidden Winch Kit with special XD 9000 Short Drum Winch For Ford F-150 Truck INSTALLATION INSTRUCTIONS Part Number 69110 Hidden Winch Kit with special XD 9000 Short Drum Winch For Ford F-150 Truck As you read these instructions, you will see NOTES, CAUTIONS and WARNINGS. Each message

More information

CASS Interface System Parts Section 1

CASS Interface System Parts Section 1 Ver. 2.7 CASS USER S MANUAL Receiver CASS Interface System Parts Section 1 VPC P/N CASS P/N Description 310 115 101 1899AS265-01 CASS Receiver Interface, accepts 19 Modules Interface Device VPC P/N CASS

More information

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT INSTRUCTION MANUAL 1. DESCRIPTION KEPCO An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT BOP 1KW-MG RETROFIT KIT 219-0562 Kepco KIT 219-0562 contains the PROMs used to upgrade the firmware for BOP

More information

DL650 Odyssey Luggage Installation Guide

DL650 Odyssey Luggage Installation Guide DL650 Odyssey Luggage Installation Guide Thank you for purchasing Jesse Luggage for your Motorcycle. Our Luggage, handcrafted in the USA, is designed for those with an interest in finding the most durable

More information

HS6E - L 4 4 B 01 - G

HS6E - L 4 4 B 01 - G HS6E Series HS6E Subminiature Interlock Switches with Solenoid HS6E features: Compact body: 75 15 75 mm 15-mm-wide, thinnest solenoid type interlock switch in the world. Reversible mounting and angled

More information

Serial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual

Serial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual Serial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual Table of contents Section Description Page 1.0 General Information 2 2.0 Specification 2 2.1 General Specification

More information

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K) IS94012-ENG - AFN 20-45 5 February 2013 - Revision 6 - Supersedes edition of 28 January 2013 Page 1 of 7 CAUTION: Read instructions thoroughly and completely prior to beginning installation. Installation

More information

Deans Switch Microfluidics

Deans Switch Microfluidics TRACE 1300 and TRACE 1310 Gas Chromatographs Deans Switch Microfluidics Installation Guide 31709740 Revision A June 2014 2014 Thermo Fisher Scientific Inc. All rights reserved. TRACE 1300, and TRACE 1310

More information

Connection kits for joining all types of DEVI self-limiting heating cables to cold tails

Connection kits for joining all types of DEVI self-limiting heating cables to cold tails Intelligent Heating Connection kits for joining all types of DEVI self-limiting heating cables to cold tails Fitting set (art. no. 19805761) Cold tail fitting set: 1 crimp tube type 12/3, L =20 mm 2 crimp

More information

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522 Supplementary instructions Water cooling - MINITRAC 31 Active water cooling system for radiationbased sensors Document ID: 48522 Contents Contents 1 Product description... 3 1.1 Configuration... 3... 4

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR PASSENGER AND CREW DOORS. DESCRIPTION AND OPERATION Serials 000 thru 00: The two crew/passenger doors incorporate a flush-mount outside door handle, key-operated door lock, and a conventional

More information

Section 5: Parts Replacement

Section 5: Parts Replacement Section 5: Parts Replacement Should the STAR TRAC 4500 Treadmill experience a problem requiring replacement of a specific part, the following procedures will help and instruct in the replacement of major

More information

C A Heating Cable Gland Kit Installation Instructions

C A Heating Cable Gland Kit Installation Instructions C75-100-A Heating Cable Gland Kit Installation Instructions Description The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

Operating Instructions CYR52

Operating Instructions CYR52 BA01300C/07/EN/02.14 71261315 Products Solutions Services Operating Instructions CYR52 Ultrasonic cleaning Document information Warnings The structure, signal words and safety colors of the signs comply

More information

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content 1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Model No. Description CONCEPT AND MAIN APPLICATIONS Specification HR2800, HR2810, HR2811F HR2810T, HR2811FT Rotary Hammers 28mm (1-1/8") HR2800 series models have been developed as

More information

User and Fitting Manual June 2008

User and Fitting Manual June 2008 User and Fitting Manual June 2008 Electric Curtain Track System Silent Gliss 5090 User and fitting Manual Silent Gliss 5090 Page Copyright June 2008 by Silent Gliss International Ltd., 3073 Gümligen/Berne

More information

INSTRUCTIONS FOR INSTALLING MIND/MOTION SENSOR/E-PORT ON USI ALPINE FOOD MACHINE

INSTRUCTIONS FOR INSTALLING MIND/MOTION SENSOR/E-PORT ON USI ALPINE FOOD MACHINE INSTRUCTIONS FOR INSTALLING MIND/MOTION SENSOR/E-PORT ON USI ALPINE FOOD MACHINE Read these instructions carefully before installing the kit. If you are having problems installing the kit, please call

More information

Injector Extraction Kit for the M9R / M9T

Injector Extraction Kit for the M9R / M9T Work Instructions Injector Extraction Kit for the M9R / M9T 60385095 Tensile Force Limiter 60385229 page 1 of 40 page 2 of 40 Safety notice Important! Be sure to read these instructions before assembling,

More information

Guide to adding a current selection switch to the DIY Portable EVSE from ZCW

Guide to adding a current selection switch to the DIY Portable EVSE from ZCW Guide to adding a current selection switch to the DIY Portable EVSE from ZCW Introduction This guide is intended for those who have built the Zero Carbon World DIY Charging Station kit as depicted in the

More information

MAZDA 3 MPS FRONT MOUNTING INTERCOOLER INSTALLATION

MAZDA 3 MPS FRONT MOUNTING INTERCOOLER INSTALLATION MAZDA 3 MPS FRONT MOUNTING INTERCOOLER INSTALLATION Tools needed: 7mm Hose clamp driver 10mm,12mm sockets and suitable ratchet with extensions Flat bladed screwdriver Pliers Phillips screwdriver KIT CONTENTS

More information

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM _ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take

More information

Manual Supplement. Manual Title: BT510 Users Supplement Issue: 1 Print Date: May 2014 Issue Date: 3/15 Revision/Date: Page Count: 7

Manual Supplement. Manual Title: BT510 Users Supplement Issue: 1 Print Date: May 2014 Issue Date: 3/15 Revision/Date: Page Count: 7 Manual Title: Supplement Issue: 1 Print Date: May 2014 Issue Date: 3/15 Revision/Date: Page Count: 7 This supplement contains information necessary to ensure the accuracy of the above manual. 2015 Fluke

More information

C15C C15C. Page 1 of 20

C15C C15C. Page 1 of 20 2 x Lid Front Hinge 1135 8 x M8 Bolt 8 x M8 Washer (3mm Thick) 4 x M6 Large washers 4 x M6 Spring washers 4 x M6 x 40mm Bolts 6 x M6 20mm Bolts 6 x M6 Washers 20 x Screws 2 x Lid mount gas strut bracket

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual 1610131300 Rev B 17Jun2017 1 Fig. 1.1 DIM S INCH [MM] Fig. 1 Designed for maximum sanitary use, the 8374 Automatic Roll Towel Mechanism automatically

More information

HS1C Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Model No. Description DP4010, DP4011 2-Speed Drill 13mm (1/2") L PRODUCT P 1/ 8 CONCEPT AND MAIN APPLICATIONS Models DP4010 and DP4011 have been developed as 13mm (1/2") Drill for

More information

MIC210 Electric Farm Conversion Instructions

MIC210 Electric Farm Conversion Instructions MIC210 Electric Farm Conversion Instructions Note: Apply the supplied Dielectric Lubricant to all wire connections when each wire is hooked up. The Dielectric Lubricant will help to prevent corrosion.

More information

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control

More information

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

UNPACK AND IDENTIFY THE FOLLOWING PARTS. SUT-250-M2 ASSEMBLY REQUIREMENTS *Torque all T-bolt nuts to 35-40 foot pounds. *Check all lights before towing. *Tire pressure not to exceed recommendation on serial tag. *Re-torque wheel nuts after first

More information

SUT-450-I ASSEMBLY REQUIREMENTS

SUT-450-I ASSEMBLY REQUIREMENTS SUT-450-I Torque wrench, carpenters square, wire cutters, Phillips screwdriver, 7/16, 9/16, and 3/4 combination wrenches, ratchet, 9/16,3/4,13/16, and 7/8 sockets. ASSEMBLY REQUIREMENTS *Torque all T-bolt

More information

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport Sachs shock manual (2013 2015) 2 & 4 Stroke RR Enduro (2014-2015) RS Dual Sport 1 Introduction The procedures in this manual must take place in a clean environment using professional tools and some specific,

More information

NCR ma/hart four-wire

NCR ma/hart four-wire Quick Setup Guide Radar sensor for continuous level measurement of bulk solids NCR-80 4-20 ma/hart four-wire www.binmaster.com Mounting Mounting preparations, mounting strap The strap is supplied unassembled

More information

Installation instructions

Installation instructions Service Installation instructions Audi A3 (8V3) 2012 Roof bars 8V3.071.126 for vehicles with bright moulding package (PR no. 4ZB) and roof bars 8V3.071.126.L for vehicles with black moulding package (PR

More information

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999 STOCKPORT, ENGLAND, TEL: 0161-430 8333 POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS PLEASE READ THE INSTRUCTIONS BEFORE PROCEEDING Recommended Tools ANNEX B Ref TK/AHT Issue C Date 16 August 1999 Heavy

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator SensoStar C DE-18-MI004-PTB037 (MID heat) DE-18-M-PTB-0049 (national German cooling)

More information

Original BMW Accessories. Installation Instructions.

Original BMW Accessories. Installation Instructions. Original BMW Accessories. Installation Instructions. M Performance Aerodynamics Package Retrofit Kit. BMW 4 Series Coupé (F32) BMW 4 Series Convertible (F33) BMW 4 Series Gran Coupé (F36) Retrofit kit

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

Guidance to Installers of Viridian EV Charging Stations

Guidance to Installers of Viridian EV Charging Stations Guidance to Installers of Viridian EV Charging Stations Iss 6 - Jul 2016 Page 2 of 9 This guide is intended to instruct in the proper installation of a Viridian EV Charging Station. Please note that when

More information

101B, 210X, ELM, 101X Frame Installation & Service Manual

101B, 210X, ELM, 101X Frame Installation & Service Manual 101B, 210X, ELM, 101X Frame Installation & Service Manual 99-16105-S001_B Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data

More information