OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012
|
|
- Ambrose Bond
- 5 years ago
- Views:
Transcription
1 STANDING SEAM OVERVIEW SW-2 CB-2 CB-1 R-1 RK-1 V-1 SW-1 RK-1 H-1 VR-1 P-1 HW-1 PB-1 DE-2 DE-1 RK-3 DE-2 SP-1 OV-1
2 DRIP EDGE - 1 6" WIDE HIGH TEMP UNDERLAYMENT STRIP PRE-NOTCHED PANEL END STANDING SEAM DRIP EDGE CLEAT FASTENER CLEAT (OPTIONAL) WOOD BLOCKING DE-1
3 DRIP EDGE - 2 6" WIDE HIGH TEMP UNDERLAYMENT STRIP PRE-NOTCHED PANEL END APPROPRIATE GASKETED FASTENER (SEALANT BEHIND DRIP EDGE TO SEAL) DRIP EDGE GUTTER WOOD BLOCKING DE-2
4 DRIP EDGE - 3 6" WIDE HIGH TEMP UNDERLAYMENT STRIP PRE-NOTCHED PANEL END CONTINUOUS OFFSET CLEAT SET IN BUTYL APPROPRIATE OFFSET CLEAT FASTENER APPROPRIATE FLASHING FASTENER EAVE FLASHING CLEAT FASTENER DRIP CLEAT WOOD BLOCKING DE-3
5 DRIP EDGE - 4 APPROPRIATE FLASHING FASTENER APPROPRIATE OFFSET CLEAT FASTENER PRE-NOTCHED PANEL END OFFSET CLEAT SET IN BUTYL EAVE FLASHING APPROPRIATE GASKETED FASTENER (SEALANT BEHIND DRIP EDGE TO SEAL) WOOD BLOCKING GUTTER DE-4
6 RAKE EDGE - 1 1/4" DIA. BEAD OF SEALANT RAKE CAP CLEAT CONTINUOUS BEAD OF SEALANT WOOD NAILER RAKE FLASHING RAKE CLEAT 1" MIN. RK-1
7 RAKE EDGE - 2 1/4" DIA. BEAD OF SEALANT J-CLOSURE CONTINUOUS BEAD OF SEALANT WOOD NAILER RAKE FLASHING RAKE CLEAT 1" MIN. RK-2
8 RAKE EDGE - 3 1/4" DIA. BEAD OF SEALANT Z-FLASHING CONTINUOUS BEAD OF SEALANT WOOD NAILER RAKE FLASHING RAKE CLEAT 1" MIN. RK-3
9 RAKE EDGE - 4 PANEL CLIP APPROPRIATE RAKE FASTENER BUTYL SEALANT FIELD HEM PANEL OVER RAKE FLASHING WOOD NAILER RAKE CLEAT (IF REQUIRED) RAKE FLASHING 1/2" MIN. 1/2" MIN. RK-4
10 RAKE EDGE - 5 PANEL - FIELD BEND SEAM LEG J-CLEAT 1/4" DIA. BEAD OF SEALANT RAKE FLASHING OVER J-CLEAT 1.75" (44.5mm) MIN. WOOD NAILER STAGGERED FIELD CRIMP HEM CLOSED 1/2" MIN 1/2" MIN RK-5
11 RAKE EDGE - 6 1/4" DIA. BEAD OF SEALANT RAKE CAP MODIFIED J-CHANNEL CONTINUOUS BEAD OF SEALANT WOOD NAILER RAKE FLASHING RAKE CLEAT RK-6
12 VALLEY FLASHING - 1 TAB & FOLD PANEL END DOWNSLOPE 3 CONTINUOUS BEADS OF 1/4" DIA. SEALANT CONTINUOUS VALLEY CLEAT SET IN BUTYL TAPE STRIP IN WITH MIN. 6" WIDE STRIP OF VALLEY FLASHING 6" MIN. V-1
13 VALLEY FLASHING - 2 CONTINUOUS BEAD OF SEALANT SAW CUT REGLET OR SURFACE MOUNT FLASHING 6" WIDESTRIP OF HIGH TEMP UNDERLAYMENT CONTINOUS STARTER CLEAT SET IN BUTYL TAPE, FASTENED WITH TAB & FOLD PANEL END DOWNSLOPE 8" MIN. VALLEY/RAKE FLASHING, FASTENED WITH V-2
14 HIP CAP ASSEMBLY - 1 TURN UP LEG AND SEAL WITH SEALANT, 4 PER Z Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT 1/4" DIA. BEAD OF SEALANT HIP CAP 2" MIN. H-1
15 RIDGE CAP ASSEMBLY - 1 TURN UP LEG AND SEAL WITH SEALANT, 4 PER Z Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT 1/4" DIA. BEAD OF SEALANT RIDGE CAP 2" MIN. R-1
16 VENTED RIDGE CAP ASSEMBLY - 1 TURN UP LEG AND SEAL WITH SEALANT, 4 PER Z VENTED Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT 1/4" DIA. BEAD OF SEALANT RIDGE CAP 2" MIN. VR-1
17 3" MIN. HIP/RIDGE CAP SPLICE - 1 RIDGE/HIP CAP PREVAILING WIND (3) CONT. 1/4" DIA. BEADS OF BUTYL SEALANT AT ALL OVERLAPPING FLASHING SPLICE JOINTS 3" (76.2 mm) MIN. (3) CONT. 1/4" DIA. BEADS OF BUTYL SEALANT AT ALL OVERLAPPING FLASHING SPLICE JOINTS NOTCH HEM TO RECIEVE HEM OF OVERLAPPING PANEL HRSP-1
18 MULTIPLE RIDGE MITERS - 1 DETAIL A-A CLOSE w/ URETHANE SEALANT OPTIONAL PEAK CAP ANGLE VARIES BY HIP ANGLE & ROOF SLOPE X STAINLESS STEEL POP RIVET, 3" (76.2 mm) O.C. MAX CLOSED HEM REFER TO RIDGE DETAIL HEM UNDER Z CLOSURE COMPLETED CAP BRAKE LINE 1/4" DIA. BEAD OF SEALANT A A NOTE: SHOWN AS FOUR SEGMENTS. NUMBER OF REQUIRED SEGMENTS AND SIZE OF EACH SEGMENT IS PROJECT SPECIFIC MR-1
19 SIDE WALL ASSEMBLY - 1 MIN. 6" WIDE HIGH TEMP UNDERLAYMENT EIFS OR OTHER WALL PANEL SYSTEM APRON FLASHING, SIDE WALL TURN UP LEG AND SEAL CONTINUOUS SEALANT J-CLOSURE, PANEL SET IN CONTINUOUS SEALANT AT THE BOTTOM AND SIDE SW-1
20 SIDE WALL ASSEMBLY - 2 S CONTINUOUS SEALANT SAW CUT REGLET FLASHING APRON FLASHING, SIDE WALL TURN UP LEG AND SEAL J-CLOSURE, PANEL SET IN CONTINUOUS SEALANT AT THE BOTTOM AND SIDE SW-2
21 SIDE WALL ASSEMBLY - 3 MIN. 6" WIDE HIGH TEMP UNDERLAYMENT EIFS OR OTHER WALL PANEL SYSTEM APRON FLASHING, SIDE WALL TURN UP LEG AND SEAL WITH SEALANT Z-CLOSURE SET IN SEALANT, 1/4" DIA, BEAD OF URETHANE SEALANT BETWEEN THE APRON FLASHING AND Z BLOCKING SW-3
22 SIDE WALL ASSEMBLY - 4 S CONTINUOUS SEALANT SAW CUT REGLET FLASHING APRON FLASHING, SIDE WALL TURN UP LEG Z-CLOSURE SET IN SEALANT, 1/4" DIA, BEAD OF URETHANE SEALANT BETWEEN THE APRON FLASHING AND Z SW-4
23 CURB ASSEMBLY ASSEMBLY - 1 RUN ONE 1/4" DIA. BEAD OF BUTYL UP 6" FROM LOW END OF PANEL TO MARRY WITH FACTORY APPLIED SEALANT IN SEAM (OPTION) 3-1/4" DIA. CONT. BEADS OF BUTYL SEALANT CURB BACK FLASHING CURB APRON FLASHING CONTINUOUS CLEAT 3/16" x 7/8" BUTYL TAPE 3" MIN. ON EACH SIDE CB-1 FABRICATED CRICKET IF REQUIRED 12" MIN. 6" MIN. CB-2 SUBSTRATE SUBSTRATE ZEE-CHANNEL SET IN 3/16" x 7/8" DOUBLE BEAD BUTYL TAPE, FILL HEM OF FLASHING AND SPACE BETWEEN ZEE & PANEL SEAM w/ URETHANE SEALANT CB-1
24 CURB ASSEMBLY ASSEMBLY - 2 CURB FLASHING BUTYL TAPE ZEE CLOSURE FILL WITH URETHANE SEALANT P-2A 12" MIN. P-2B TURN UP PANEL TO FORM LEG THAT EQUALS THE SEAM HEIGHT CB-2
25 HEAD WALL ASSEMBLY - 1 MIN. 6" WIDE HIGH TEMP UNDERLAYMENT EIFS OR OTHER WALL PANEL SYSTEM APRON FLASHING, HEAD WALL TURN UP LEG AND SEAL WITH SEALANT Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT HW-1
26 HEAD WALL ASSEMBLY - 2 CONTINUOUS BEAD OF URETHANE SEALANT SAW CUT REGLET FLASHING FIRESTONE APPROVED UNDERLAYMENT APRON FLASHING TURN UP PANEL AND SEAL WITH SEALANT Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT WALL / CURB (MASONRY / CONCRETE SUBSTRATE ONLY) HW-2
27 VERTICAL RIDGE ASSEMBLY - 1 SEAL THE END OF THE PANEL ENDS WHERE TURNED UP Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT VERTICAL RIDGE FLASHING WOOD NAILER CLEAT 1/2" MIN. 1/2" MIN. HE-1
28 ROUND PENETRATION ASSEMBLY - 1 UNDER NO CIRCUMSTANCES CAN THE PIPE PENETRATE OR COME WITHIN 4" OF THE PANEL SEAM. OTHERS (OPTIONAL) HIGH GRADE SEALANT FIELD FABRICATED METAL HOOD BY OTHERS (OPTIONAL) CONTINUOUS BEAD OF SEALANT STAINLESS STEEL CLAMPING RING CAUTIONS: 1) PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, FOREIGN DEBRIS, ETC. 2) PIPE MUST BE ANCHORED TO ENSURE STABILITY. 3) PRE-MOLDED PIPE FLASHING MAY BE CUT TO HEIGHT, BUT NO LOWER THAN REINFORCING RING ( NO WRINKLES OR FOLDS UNDER CLAMPING RING). 4) APPLY SEALANT BETWEEN PENETRATION AND PRE-MOLDED PIPE FLASHING PRIOR TO INSTALLATION OF CLAMPING RING. 5) DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS 180 F. 6) PIPE SHOULD EXTEND A MINIMUM OF 8" ABOVE ROOF SURFACE. 7) WHERE SNOW AND ICE ARE COMMON, IT'S RECOMMENDED UP-SLOPE OF PENETRATIONS THAT ICE/SNOW-DAM PROTECTION IS USED PRE-MOLDED PIPE FLASHING w/ ALUMINUM BASE APPROPRIATE GASKETED FASTENER 1.5" O.C. MAX. MUST NOT PENETRATE SUBSTRATE ROUND PENETRATION 2" MIN. SHEATING P-1
29 PANEL SPLICE ASSEMBLY - 1 MIN. 6" WIDE HIGH TEMP UNDERLAYMENT STRIP EXPLODED VIEW STARTER CLEAT SET IN BUTYL TAPE 3 CONTINUOUS BEADS OF 1/4" DIA. BEADS OF BUTYL SEALANT NOTE: STAGGER ADJACENT END LAPS MINIMUM of 12" 1" MIN. 6." MIN. FIELD TRIM TOP OF SEAM TO ALLOW FOR NESTING FINISHED VIEW SP-1
30 LOW SLOPE TRANSITION ASSEMBLY - 1 CONTINUOUS STARTER CLEAT SET IN BUTYL TAPE; EPDM & MUST NOT COME IN CONTACT EPDM/TPO MEMBRANE BONDING ADHESIVE APPROVED FASTENER AND 2" METAL PLATE TIE-IN STRIP BONDING ADHESIVE LOW SLOPE INSULATION 8" (203.2 mm) MIN. DECK BLOCKING, AS REQUIRED LST-1
31 SNOW GUARD ASSEMBLY - 1 PANEL VERTICAL SEAM SNOW RETENTION SYSTEM AFFIXED TO PANEL SEAM WITH NON-PENETRATING SET SCREWS; MUST NOT PENETRATE PANEL OR SEAMS SG-1
32 PITCH BRAKE ASSEMBLY - 1 CONTINUOUS STARTER CLEAT SET IN BUTYL TAPE PRE NOTCHED PANEL END PITCHBREAK FLASHING Z-CLOSURE SET IN SEALANT, FILLTHE SPACE BETWEEN Z & PANEL SEAM w/ URETHANE SEALANT PB-1
MIRAGE. Panel Options: Details: Notes: Mirage. Mirage Test Data. Section Properties or Load Tables. - Panel width: 16 - Panel configurations: ribbed
MIRAGE Mirage Panel 8 8 1 16 Coverage Mirage Mirage Test Data. Section Properties or Load Tables For any available Testing Data, Section Properties, or Load Tables, please visit www.mcelroymetal.com. For
More informationMETAL BUILDING AND STANDING SEAM COMPONENTS
METAL BUILDING AND STANDING SEAM COMPONENTS COMMERCIAL AND INDUSTRIAL KENTUCKY ILLINOIS 925 Rolling Hills Ln. 1181 S.R. 121 Winchester, KY 40391 Mt. Zion, IL 62549 TEL: 859-744-4475 TEL: 217-864-5835 FAX:
More informationInstallation. Storage. Tools
Contents Page Installation, Storage, Tools 2 Safety Tips, Maintenance, Important Notice... 3 Direction of Application.. 4 Installation Details Overview. 5 Eave and Gable Details. 6 Wall Flashing Details..
More informationMAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS
PO Box 7000 Carlisle, PA 17013 800-211-7170 MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS 07319.1 Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3
More informationMAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,
More informationMAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product
More informationPressure Sensitive Seam Tape Features 30.5m long rolls or sold by the metre (can be sold by 10th of metre). Must be used with an EPDM primer.
3 inch tape (75mm) Pressure Sensitive Seam Tape PS Seam Tape manufactured to precise width and thickness criteria with a clear poly backing for easier on site application. This Seam tape offers over 30%
More informationProduct Installation Guide. Revised 8/25/14
Product Installation Guide Revised 8/25/14 POLYCARBONATE PANELS 29GA FLAT SHEETS WEATHEREDGE PANEL OPTIONS CLEAR PANELS WHITE PANELS FASTENERS (100 cnt bags) NON-VENTED S ROOF BOOTS FASTENER INSTALLATION
More informationMAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,
More informationSENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM Part 1 GENERAL PAGE 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,
More informationEMPIRE NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com EMPIRE NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product
More informationPermashake II Roof Panels ATAS LIST PRICING
All prices are subject to change without notification Permashake II panels are a simulated wood shake pattern Available in Redwood, Forest Green, Slate Grey & Sierra Tan s are with a PVDF finish Panels
More informationEMPIRE SLATE ECOSTAR GOLD STAR ROOF SYSTEM
42 Edgewood Drive Holland, NY 14080 www.ecostarllc.com EMPIRE SLATE ECOSTAR GOLD STAR ROOF SYSTEM PAGE Part 1 GENERAL 1.01 Description 2 1.02 Quality Assurance 2 1.03 Submittals 3 1.04 Product Delivery,
More informationRidge cap AR '-2" 14" 7.69# AR '-2" 20" 10.98# AR '-2" 20 ½" 11.26#
Ridge ap 2 6 3/ 3 ITEM DESRIPTION PRIE PER EAH 3 6 3/ 2 AR-100 10'-2" 1 7.69# 26.60 33.55 Ridge cap 9 3/ 4 1/8" 5" 5" 9 3/ 4 1/8" AR-101 10'-2" 20" 10.98# 35.25 45.15 Flat Ridge/hip 9 3/ 9 3/ AR-102 10'-2"
More informationTRIM PART AR '-2" 14" 7.69# PART AR '-2" 20" 10.98# PART AR '-2" 20 ½" 11.26#
Ridge ap 2 6 ITEM DESRIPTION PRIE PER EAH 6 2 AR-100 10'-2" 1 7.69# 24.05 24.85 Ridge cap 9 4 1/8" 5" 5" 9 4 1/8" AR-101 10'-2" 20" 10.98# 31.65 32.65 Flat Ridge/hip 9 9 AR-102 10'-2" 20 ½" 11.26# 32.25
More informationHome Depot Direct Special Order Retail Pricing 26 Gauge MIGHTI RIB
26 Gauge MIGHTI RIB MIGHTI RIB SKU # Retail UOM Model # Description 26842 $ 2.93 LnFt 49406 26ga Mighti Rib Plain Galvalume 2729 $ 3.40 LnFt 49403 26ga Mighti Rib Painted Galvanized White 899 Light Stone
More informationGRAVITY VENTILATORS SIZING
GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to
More information17600 Badtke Road Hockley, TX COMP (2667) Toll Free Tel Fax.
ullman, Alabama 35055 1.866.749.OMP (2667) Toll Free RIDGE AP 2 6 ITEM. DESRIPTION PRIE PER EAH 6 2 AR-100 10'-2" 1 7.69# 26.60 33.55 RIDGE AP 9 4 1/8" 5" 5" 9 4 1/8" AR-101 10'-2" 20" 10.98# 35.25 45.15
More informationBracket U Value at 1.5M Centres. 265mm 275mm 295mm 300mm 315mm 335mm 355mm mm.
Bracket Typically @ 1200 ELITE SYSTEMS 402 Top Sheet set out typically for straight sheets * Varies - See Table 39 75 Varies - See Table 32 Bracket Height 100mm 150mm 160mm 180mm 185mm 200mm 220mm Halter
More informationComponent Parts Sales Terms & Conditions
Component Parts Sales Terms & Conditions All Orders received for component parts will be honored at our factory in accordance with the following terms and conditions. 1. Credit - All orders require a 30%
More informationHome Depot Direct Special Order Retail Pricing 24 Gauge 1 1/2" SSR
1 1/ SSR SKU # Retail UOM Model # Description w/shadow Lines Home Depot Direct 272177 $ 2.61 LnFt 4916010 24ga 1 1/ SSR Plain Galvalume 272616 $ 3.42 LnFt 4916010 24ga 1 1/ SSR Painted Galvalume Minimum
More informationEDGE METAL & ACCESSORIES FOR SINGLE-PLY ROOFING SYSTEMS
EDGE METAL & ACCESSORIES FOR SINGLE-PLY ROOFING SYSTEMS OUR PROMISE THROUGH ONGOING INTERCHANGE OF EXPERIENCES WITH CONTRACTORS, MULE-HIDE KEEPS ON TOP OF THE LATEST ROOFING REQUIREMENTS AND SOLUTIONS
More information12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 MAIN RUNNER SPLICE. SPECIFICATIONS (unless noted otherwise)
12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 4' OPEN CELL RUNNER SEE DETAIL A1.7 FOR INFILL PANEL FIXTURE OPENING RECOMMENDATIONS CROSS RUNNER FIELD CUT AT PERIMETER TYPICAL SYSTEM
More informationR-LOC TRIMS. Part Number Length. All angles are 90 or 45 unless otherwise noted. All trims are 26 gauge unless otherwise specified.
R-LOC TRIMS All angles are 90 or 45 unless otherwise noted. RAKE TRIM 150 105 105 RA102(color) RA122(color) RA142(color) RA162(color) RA182(color) RA204(color) 10'-2" 12'-2" 14'-2" 16'-2" 18'-2" 20'-4"
More informationEDGE METAL & ACCESSORIES FOR SINGLE-PLY ROOFING SYSTEMS
EDGE METAL & ACCESSORIES FOR SINGLE-PLY ROOFING SYSTEMS OUR PROMISE THROUGH ONGOING INTERCHANGE OF EXPERIENCES WITH CONTRACTORS, MULE-HIDE KEEPS ON TOP OF THE LATEST ROOFING REQUIREMENTS AND SOLUTIONS
More informationFL ATi RON STEEL FLASHING DETAILS 11/4 STUD PANEL (PBR) PANEL PROFILE. 36 Coverage
26 Gauge Trim Pamphlet.indd 1 5/8/12 5:05 PM FL ATi RON STEEL FLASHING DETAILS 11/ STUD PANEL (PBR) PANEL PROFILE 1¼ 12 36 Coverage All specifications are designed to be used with panel profile heights
More information2006 PRICE LIST. PRODUCT NAME DESCRIPTION PAGE Policies Freight policy and material return policy. 1. Product Reference Table. Majestic Slate Tile
Effective June 1st 2006 PRICE LIST PRODUCT NAME DESCRIPTION PAGE Policies Freight policy and material return policy. 1 Product Reference Table Table provides weight, packaging, and installation information
More informationPage 1 of 29 2003 Ford Thunderbird 3.9L Eng WATER LEAKS - REMOVABLE ROOF AND CONVERTIBLE TOP - SERVICE TIPS TECHNICAL SERVICE BULLETIN Reference Number(s): 04-9-5, Date of Issue: May 17, 2004 FORD: 2002-2005
More informationTURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)
TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with
More informationTURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)
TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof
More informationPRODUCT GUIDE THE PERFECT PARTNER FOR THE TRADE
THE PERFECT PARTNER FOR THE TRADE CONTENTS PAGE NO. 03 04 05 06 07 08 09 10 11 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 Product Identification System Specification Glazing Bars PVC and Aluminium Cappings
More informationPRODUCT EVALUATION Effective Date: July 1, 2014 RC-20
TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / M03-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective
More informationKark Residence Page 1 of 6
Kark Residence Page 1 of 6 Materials 1 2 2x12x16' SYP #2 Eave Blocking EA 2 --$$$-- $0.00 2 6 2x12x12' SYP #2 Header Girder 12' EA 6 --$$$-- $0.00 3 21 2x12x14' SYP #2 Header Girder 14' EA 21 --$$$-- $0.00
More informationMounting SySteMS ApplicAtionS overview version 1.2 March 2013
Mounting Systems Applications Overview Version 1.2 March 2013 tritec Mounting Systems: Applications Overview I. Pitched Roof: Roof-Top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND on tiles 1.1.1
More informationGasfire Flue Kits. B Vent Gas Flue Kit - Metallic Black (galvanised)
Gasfire Flue Kits Product Description Part Number B Vent Gas Flue Kit - Metallic Black 588649 (galvanised) Geneva (Ultimate) This kit contains: Gas Cowl, Top Spider, Slip Liner 400mm, Outer Liner 1200mm,
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 1.5 April 23, 2013 Copyright 2013 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing, electrical,
More informationLLOYD INDUSTRIES INC.
1-1/2 HOUR FIRE/SMOKE DAMPER FIRE/SMOKE DAMPER VERTICAL OR HORIZONTAL MOUNT 1-1/2HR RATING (Bi-Directional) (For use in 2hour or less rated partitions) Located in pin grooves. Minimum Size Single Section
More informationR & S Manufacturing and Sales Company
R & S Manufacturing and Sales Company KNOCKED DOWN RIDGE VENTS RV9-12 ASSEMBLY INSTRUCTIONS April 2013 PARTS LIST End Caps (2 per vent) Wind Bands (2 per vent) Skirt Flashings (2 per vent) Skirt Cross
More information3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology
3.0 RAIL-FREE RACKING Utilizes EcoFasten Solar s patented technology Document Date: 05.08.2018 Contents Pg. 1... Assets of Design Features System Components Pg. 2... Rock-It 3.0 Mount Assembly Rock-It
More informationSECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
SECTION 10 51 13 METAL LOCKERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Heavy Duty Welded Gear Lockers. B. Locker benches. 1.02 REFERENCES A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.
More informationRiva Plus HEAT ONLY & COMBI BOILER. Please Read This Guide Carefully and Save for Future Reference
Condensing Vent Component & Installation Guide Riva Plus HEAT ONLY & COMBI BOILER Please Read This Guide Carefully and Save for Future Reference - This guide is intended to provide detailed information
More informationWRSS Wraparound Repair Sleeve Installation Instructions
WRSS Wraparound Repair Sleeve Installation Instructions TECP-30-263. Issue 1. 4/2016 1.0 General Product Information This practice provides information regarding the description and use of Raychem s WRSS
More informationHVS S 15kV Class
Product HVS-3-1580S 15kV Class Transition Splice for 3/C to 3/C Extruded Dielectric (Poly/EPR) Power Cables Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-54864, Rev
More informationINSTALLATION INSTRUCTIONS MODEL KFD-555
AIR MOVEMENT PROS & HORIZONTAL MOUNT ATTACHING S TO S Fire dampers must be attached to sleeves as shown in fig. 1. All four sides of the damper frame must be attached to the sleeve with one row of attachments
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 3.2 December 15, 2015 Copyright 2015 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing,
More informationStandard Installation Fire Damper Models: 319, 319(SS), D39
Standard Installation Fire Damper Models: 319, 319(SS), D39 Page 1 or 6 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the damper is
More informationSAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT
SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT C A R L I S L E D R Y L I G H T Innovation, Expertise and Stability For more than 45 years, Carlisle SynTec has been a leader in the commercial roofi
More information77'-0" 77'-0" 40'-4" 9'-0" 0'-0" 1'-4" Site Plan Maximum Impervious Coverage Scale: /2"=1'-0" SET BACK (REAR) SET BACK (FRONT) 140'-0" 60'-8" 52'-4" 27'-0" 11'-8" 11'-8" 8'-8" 1'-8" FUTURE POOL POOL DECK
More informationREMOVAL AND INSTALLATION
501-11-1 Glass, Frames and Mechanisms 501-11-1 REMOVAL AND INSTALLATION Windshield Glass Special Tool(s) Rotunda Pneumatic Knife with Offset Blade 107-R1511 or equivalent The Pumper 164-R2459 or equivalent
More information450 OE/HS Installation Guide
450 OE/HS Installation Guide Offered by Signature Automotive Products For 2011 The Signature Automotive Products Spoiler is the most advanced technological spoiler sunroof and is available in two models:
More informationHOESCH FLASHINGS AND ACCESSOIRES SOUTH TECHNICAL INFORMATION. GermanEngineered
HOESCH FLSHINGS ND CCESSOIRES SOUTH TECHNICL INFORMTION GermanEngineered Contents Roof and wall connections 6 General..............................................................6 Hoesch isodach mono
More informationDRYER EXHAUST VENT FLASHINGS
SECTION B DRYER EXHAUST VENT FLASHINGS A-0 DRYER EXHAUST VENT FLASHINGS TABLE OF CONTENTS Thaler Or Equal Dryer Exhaust Vent Flashings (Flat/Low Slope Roofs) Dryer Exhaust Vent Flashings (Sloped Roofs)
More information4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology
4.0 RAIL-FREE RACKING Utilizes EcoFasten Solar s patented technology Document Date: 3.2.2018 Contents Pg. 1 Assets of Design Features System Components Pg. 2 Rock-It 4.0 Mount Assembly Rock-It 4.0 Coupling
More informationHi-Tech specially designed components allow for fast and easy assembly.
OPEN SHELVING MEDIUM, HEAVY AND EXTRA HEAVY-DUTY HI-TECH STEEL SHELVING Open Starter Units Include: Two beaded front posts, two angle back posts, one pair of back sway braces, two pair of side sway braces
More informationDistributed by: BEST MATERIALS Ph: , Fax:
Distributed by: BEST MATERIALS Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials.com Dektite Product Guide Flashings for Metal Roofs Dektite Original The
More informationSECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.
Section 10_51_13_MetalLockerPenco-ProTough_8-19-09 PART 1 GENERAL SECTION 10 51 13 METAL LOCKERS 1.01 SECTION INCLUDES A. Heavy Duty Welded Tubular Frame Lockers. B. Locker benches. 1.02 REFERENCES A.
More informationLED ROLLER LIGHTING. LED Components... 6
SERVICE MANUAL LED ROLLER LIGHTING RV SPECIFICATIONS MOUNTING: LENGTH: POWER: CONTROLS: TABLE OF CONTENTS LED light strip is factory mounted in a specially designed roller tube. Wire is concealed in canopy
More informationDesign of a Station for Pump Testing
Design of a Station for Pump Testing The system below was developed for use in the First Year Engineering Program at Louisiana Tech University. Using water around electrical devices can be hazardous. Louisiana
More informationCantilever Series Mounting Instructions Fullsize Sprinter Van (US) All except WB (AA) present
Fullsize Sprinter Van (US) All except 3500 144 WB (AA)- 2007-present Preparing the Gate 1. Remove the platform, mounting kit, license plate assembly, and bridge assemblies, which are banded to the main
More informationTri-Boro Shelving Features
6Steel Shelving Tri-Boro Shelving Features Tri-Boro Shelving is manufactured in the widest range of sizes available in the industry. When used in combination this array of sizes can meet the most demanding
More informationGeneral Motors. The Collision Repair Industry Leader.
General Motors. The Collision Repair Industry Leader. This booklet provides you with detailed repair information. It is important to note that serviceability has been an integral part of the development
More information2007 Toyota FJ Cruiser By Gilbert R. Gutierrez
2007 Toyota FJ Cruiser By Gilbert R. Gutierrez Vehicle information Vehicle type: Four-door utility vehicle NAGS numbers*: Windshield part number FW02652GTY; front door glass FD23053-54GTY R-L; rear door
More informationInstallation Instructions
Tile Integrated Mounting System Installation Instructions This document describes basic installation procedures for Zep Solar s tile-integrated mounting system for use with Zep Compatible PV modules installed
More informationACCESSORIES AND FLASHINGS
CCESSORIES ND FLSHINGS FOR SNDWICH PNELS TECHNICL CTLOGUE www.balex.eu CCESSORIES and FLSHINGS for sandwich panels January 2011 The content of this folder does not constitute a commercial offer in the
More informationBe sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
5 NOVEMBER 2010 COYOTE Dome 9.5 x 28 Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1. 7. 2. 4. 10.
More informationProduct and Price Guide
Dektite Product and Price Guide Easy to Work With www.deks.co.uk sales@deks.co.uk 01275 858866 Flashings for Metal Roofs Dektite Original The Original watertight Flashing for Metal Roofs The original watertight
More informationED 42. ENGINE HOOD / DOOR FRONT DOOR (w/o Power Window)
42 ENGINE HOOD / DOOR FRONT DOOR (w/o Power Window) (g) (h) Horizontally and vertically adjust the door by loosening the door side hinge bolts. Tighten the door side hinge bolts after the adjustment. Torque:
More informationLocation Reference of Standard Trims
Location Reference of Standard Trims Trims Replaces: Apr 1, 2011 1 6 9 7 5 12 10 11 1 2 15 1 1 5 8 6 9 7 2 11 10 12 15 1 Reference Number & Description 1 Ridge Cap 2 Inside Corner Outside Corner Outside
More informationRemoving and installing front windscreen
51 31 000 Removing and installing front windscreen To bond windshield: Adhesives for cold and hot working are permitted. Remove interior rearview mirror, refer to 51 16 060. If necessary, remove rain sensor,
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationNATEF Task List - Collision Repair & Refinish Non-Structural Analysis & Damage Repair
For every task in Non-Structural Analysis and Damage Repair, the following safety requirements must be strictly enforced: Comply with personal and environmental safety practices associated with clothing
More informationTU-WAY ROOF VENTILATORS
BULLETIN 615 December 2000 TU-WAY ROOF VENTILATORS Tu-WAY Roof Ventilators Aerovent has provided quality air moving and ventilation equipment for over sixty-five years and is a recognized leader in this
More informationInstallation Instructions
Roller & Roman Shades Lifting Systems Cassette and Sure-Lift EZ Lift Cordless EZ Pull Standard and Cassette R-Series Clutch SL-Series Clutch Spring Roller Fascias and Valances 3, 4 Flat and 4 Curved Fascia
More informationFlue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer
834449_05GB_022005.qd 02.02.2005 17:12 Uhr Seite 1 For the installer Flue installation instructions Air flue duct for use with ecomax and ecotec boilers ecomax 613/2 E ecomax 618/2 E ecomax 622/2 E ecomax
More informationPremium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1
Premium Dry Freight (Plywood) Door Installation A Premium door can be identified as usually having a two-spring balancer, 2 diameter (nominal) rollers, and end hinges with removable covers. If your Whiting
More informationMODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS
MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades
More informationMustang Shaker
2005-2009 Mustang Shaker CDC #110050 ( 05/ 06) or 0711-7000-01 ( 07/ 09) Component Check List: Quantity/Description Part # CDC Installer 1 - Engine Cover Assembly 114050 1 - Aluminum Shaker Scoop 183020
More informationQuality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS
Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with
More informationGRAVITY INTAKE AND EXHAUST ROOF VENTILATORS
GRAVITY INTAKE and EXHAUST ROOF VENTILATORS SECTION 21 GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS Series GE and GI Low Silhouette This attractive low silhouette design is available in specific versions
More informationCONTENTS. Ordering Information... Page 3. Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires...
CONTENTS Ordering Information... Page 3 Freestanding Flue Kits (Standard) Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires... Page 6 Inbuilt Flue Kits (Standard
More informationIntroduction to Automotive Collision Repair Technology
Introduction to Automotive Collision Repair Technology Introduction to Construction Materials Standard 01 Steel (Introduction to Construction Materials) Objective 01 I can explain steel strengths and the
More informationSheet metal work. Mechanisms and accessories
Sheet metal work GENERAL LOWER STRUCTURE UPPER SIDE STRUCTURE UPPER REAR STRUCTURE TOP OF BODY Mechanisms and accessories EXTERIOR PROTECTION JE0 AL - JE0 EL - JE0 HL 77 11 196 742 DECEMBER 1997 Edition
More informationWESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension
E N G I N E E R E D W O O D WESTERN SPECIFIER Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension P R O D U C T S JOIST DIMENSIONS 9½ LVL FLANGE PWI JOIST SERIES JOIST DIMENSIONS
More informationNOMAD ROOFRAIL Weatherstrip. WAGON TAILGATE & LIFTGATE Weatherstrip Dr HT ROOFRAIL Weatherstrip. CONVERTIBLE ROOFRAIL Weatherstrip
88 * Oversize Shipping / PHONE: 215-348-5568 / FAX: 215-348-0560 WAGON TAILGATE & LIFTGATE Weatherstrip 18-109 Liftgate Nomad, on body, no corners 33.00 R 18-109A Liftgate Nomad, on body Molded Corners
More informationCoating over Metal Roof: 10-Year System
Coating over Metal Roof: 10-Year System Materials Needed: Product Application Rate Application Calculator Acrylic Clear Base, Roof & Tile Primer, or Black Primer Corrugated, Standing Seam, & R-Panel 1
More informationTHE SERIES-E POWR Slider
C.R. LAURENCE CO., INC. PATENT NO. 4,920,698 THE SERIES-E POWR Slider MODEL: EPC814S 2014+ CHEVY/GMC SILVERADO/SIERRA 1500 NAGS: DY90122PK5 ELECTRIC SLIDING REAR WINDOW 2014 + CHEVY/GMC SILVERADO/SIERRA
More informationBODY (INTERIOR AND EXTERIOR)
BODY (INTERIOR AND EXTERIOR) Return to Main Table of Contents GENERAL... 2 BODY PANELING... 7 HOOD... 12 GRILLE AND MOULDINGS... 14 BUMPER... 16 FENDER... 19 WINDSHIELD... 21 REAR WINDOW GLASS... 25 FRONT
More informationAssembly Instructions
Assembly Instructions CONTENTS Product Overview... 2 List of Assembly Components... 4 General Specifications... 5 Product Inspection Report (PIR)... 6 Cutting Instructions... 10 Slats... 10 Motor Tube
More informationThermoLite 110W-330W Solar Panel Installation Instructions
ThermoLite 110W-330W Solar Panel Installation Instructions INSTALL APPLICATIONS SUPPORTED BY THIS GUIDE: 1. Trailer Roof Top Mounted 2. Bus Roof Top Mounted 3. Tractor Fairing Mounted 40W and 110W Replacement
More informationISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)
ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions
More informationMICHIGAN CITY REGIONAL TRIMS
MICHIGAN CITY REGIONAL TRIMS Length Girth POST TRIM SA(color)7 8.5" TRACK DOOR JAMB TDJT0(color) TDJT6(color) 6'".75" SOFFIT FASCIA SAF(color)5 7.5" ENDWALL FLASHING EFF(color).5" OVERHEAD DOOR JAMB OHDJ
More informationService Bodies. 9 Brutus BL48S Steel Service Body. For an 60 CA light duty chassis. Brutus Body Features. Body length step bumper
9 Brutus BL48S Steel Service Body For an 60 CA light duty chassis Brutus Body Features Body length 108 + 7 step bumper Body width 96 Cabinet height 48 Cabinet depth 24 Cabinet drop None Cabinets 12 gauge
More informationCustom Metal Fabrication - HVAC Air Duct and Fittings
Custom Sheet Metal Metal Forming Accessories Hardware Supplies Custom Metal Fabrication - HVAC Air Duct and Fittings 4120 Ridgeway Drive - Unit 28 Mississauga - Ontario - L5L 5S9 Tel 905-624-3854 / 905-290-2334
More informationNEW PRODUCTS HRANEC SHEET METAL INTRODUCES. FOR 2015! Call for. Pricing S P I R A L & O V A L M A N
HRANEC 724-437-2211 SHEET METAL INTRODUCES 2 NEW PRODUCTS Roof Ports systems are stocked for same day shipping, see page 4. FOR 2015! Call for Pricing O V A L M A N 724-437-2211 Made to order single wall
More information2014-Current. Adjustable wrench (that opens to about 1 ), 1/2 open end wrench, Phillips screwdriver, 3/8 socket, 7/16 socket, 7/32 Allen wrench
Installation Instructions Van: VNFD13TRAN65 FORD TRANSIT 148 WHEELBASE 2014-Current TOOLS REQUIRED Adjustable wrench (that opens to about 1 ), 1/2 open end wrench, Phillips screwdriver, 3/8 socket, 7/16
More informationGROUP CONTENTS FRONT BUMPER ASSEMBLY WINDSHIELD WIPER AND WASHER REAR BUMPER ASSEMBLY REAR WIPER AND WASHER...
5- GROUP 5 CONTENTS FRONT BUMPER ASSEMBLY 5- REMOVAL AND INSTALLATION 5- DISASSEMBLY AND ASSEMBLY 5- REAR BUMPER ASSEMBLY 5-4 REMOVAL AND INSTALLATION 5-4 DISASSEMBLY AND ASSEMBLY 5-4 UNDER FLOOR SPARE
More informationOVERVIEW: This bulletin involves the replacement of the header seal and its associated butyl adhesive.
NUMBER: 23-025-08 GROUP: Body DATE: August 26, 2008 This bulletin is supplied as technical information only and is not an authorization for repair. No part of this publication may be reproduced, stored
More informationTable of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct
Non-Welded Grease Duct Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: () FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR SPACE) TO COMBUSTIBLE
More informationExpedition Front Bumper Instructions
Expedition Front Bumper Instructions QTY 3D PN. FCS PART NUMBER DESCRIPTION 1 691256 A 8 E X D - 1 7 B 635-AAPLN FRONT BUMPER REPLACEMENT HARDWARE SUPPLIED 10 SELF TAPING SCREWS -10 for Front Bumper PLASTIC
More informationPart No. PAFULAxxx. Figure 2
Part No. PAFULAxxx - Exhaust Vent -To be installed prior to siding- Remove the trim ring and collar from the vent assembly. Place tape or sealant between the Exhaust Vent and house. Align the tube with
More information