EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-C

Size: px
Start display at page:

Download "EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-C"

Transcription

1 Progressive distributor VPAC Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. Clear and precise arrangement of control channels in spite of smallsize construction. Modular system construction. Quick fault remedy possible without having to loosen the pipeline. Subject to modifications 9 different proportioning volumes selectable in accordance with the lubricant required. Extremely long service life refined sliding surfaces. due to Pluggable monitoring elements can be replaced during operation. No proportioning decrease at the piston monitored. Technical data: Proportioning volume per cycle: 0,... 0,9 cm³ Lubrication point connections at max. : 0 Operating pressure at max.: 0 bar Throughput volume in case of: Oil at max.: 00 cm³/min Grease at max.: 0 cm³/min Delivery medium: Oil viscosity: > cp Grease: up to NLGI category A= Mounting position at the distributor (for visual indication and electrical checking device) at first place A= Mounting position at the distributor (for electrical checking device) at last place B = Mounting point for viewing indicator at distributor (if point A is occupied) D = DPAC proportioning block H = Main line K = Proportioning volume distinctive number M = x M8 fastening threads for assembly of auxiliary units ( see data sheet 08) R = APAD connecting plate S = Mid fastening screw Number of outlets Length "a" Length "s" Weight [kg] 0,0, 7,00 0 9,0,0,90 8, 90,0 Material: Proportioning block: Aluminium Internal parts: Steel Connecting plate: Aluminium Temperature range: C Mounting position: usually as needed Note: In case of heavy vibration or shock load, install the distributor such that piston axes are situated vertically to the main direction of shock impact. An optimum ventilation of the whole lubrication system is the precondition for its functionally safe operation. For quicker ventilation, the flow direction from bottom to top in the distributor is of advantage (inlet on bottom side). The distributor must not be "distorted". Therefore, when mounting it, always be careful that the supporting surface is level. Progressive distributor VPAC Replaces No. Page of EN EN

2 Subject to modifications Visual check Functional checks: Visual check: In a translucent polyamide casing, a red pin being fixed to the piston shows the piston's movement. Casing material: Polyamide, translucent Ambient temperature: C Weight: 0, kg Mounting point at distributor: Aor B Electrical check with initiator: Casing for initiator Casing for initiator: A pin being connected with the piston attenuates an initiator once per cycle. Version "D": Casing material: Polyamide, translucent (Piston movement is visible) for initiators with a switching distance of: 8 mm Version "W": Casing material: Polyamide, black for initiators with a switching distance of: mm Use initiator with M8x thread! (When using other initiators than those depicted below, such initiators must be checked for suitability.) Choice of initiators: Designation / Purchaseno. Suits for Initiator "C" Casing "W" Switching distancemm Initiator "F" Casing "D" and "W" Switching distance8mm Initiator "N" Casing "D" and "W" Switching distance8mm Initiator "I" Casing "W" Switching distancemm Initiator "" Casing "W" Switching distancemm Dimension drawing: Operating voltage: VDC VUC VDC VDC VDC Residual ripple: 0% % % % Load current at max.: 0 ma 00 ma 0 ma 00 ma 0 ma Protection system: IP7 IP7 IP7 IP7 IP7 Power connection: Cable m Cable m Unit plug (see accessories page ) Length "A": 0 mm mm mm 8 mm mm Page of 088 EN

3 Electrical check with reed contact Version "R" A magnet connected with the piston switches the reed contact once per cycle. Switching voltage: 0... VUC Switching current at max.: ma Switching power at max.: 0,9 VA Ambient temperature: C Mounting point at distributor: A Version "R" with DIN 0A plugin connection: Material (casing): Al or.0 IP Version "RK" Subject to modifications Version "RS" Version "RK" with cable: Material (receptacle): PA or.0 IP Cable Length: 0 m Cross section: x0,7 mm² Material: Oelflex Accessories: Cable jack for functionality check "RS" and initiator (state purchaseno., please) Cable jack with LED and cable LED yellow = function display green = operating voltage Cable jack with terminal clamps Version "RS" with unit plug, pin (M): (for matching cable jack see accessories) Material (casing): PA or.0 Cable jack with LED and cable: Purchaseno.: Operating voltage: Cable Cross section: Leng th: VDC x0, mm² m IP8 Cable jack with terminal clamps: (without LED) Purchaseno.: 9.0 type: Screws cross section at max. : 0,7 mm² Cable diameter:... mm IP7 Page of 088 EN

4 Subject to modifications Purchasedesignation: Progressive distributor (internal) VPAC.B Number of outlets Functionality check Electrical check Initiator Proportioning volume per piston stroke and outlet [cm³] distinctive number Gasket material viewing indicator without 0,0 0,0 with S without... 0 without 0 Reed contact 0, 0, NBR (Perbunane) increasing by outlets each Electrical checking device mounted at st place ) last place ) 0 Z Translucent initiator casing Switching distance 8mm Reinforced initiator casing Switching distance mm D W N F N I C F 0, 0,0 0,0 0,7 0,90 FPM (Viton) Purchasedesignation: Proportioning block DPAC Purchasedesignation: Connecting plate APAC.B Please note: ) When mounting a functional checking device at the st place, metering volume at the last place must be 0, cm³ at least! ) When mounting a functional checking device at the last place, metering volume at the last but one place must be 0, cm³ at least! Distributor view Scheme Purchaseexample: (for the distributor as depicted here) Progressive distributor with outlets, without visual check "0", with casing for initiator "W" and initiator "C", proportioning distinctive numbers "", "0", "", "0", "0", "", gasket material "P". Purchasedesignation: VPAC. B / / 0 / W / C / / 0 / / 0 / 0 / / P R : P P A V 0 0 M : K K Z K Z Z L : B B 0 0 B A Page of 088 EN

5 Combination of outlets, doubling the proportioning volume at an outlet: Connect opposing outlets by removing the "Z" screw. Close the not needed outlet with the lock screw. Without removal of the "Z" screw, no outlet must be locked. Z Addon elements and combination of outlets: Subject to modifications Distinctive letters: B = Double bridge without check valve P = Triple bridge without check valve A = Outlet at the bridge without check valve Z = opposing outlets separated K = opposing outlets connected 0 = open outlet V = Lock screw outlets are combined into one outlet by means of a triple bridge, a double bridge, and removal of the "Z" screws. Open outlets adjacent outlets are combined into one outlet by means of a double bridge. opposing outlets are combined by removing the "Z" screws. Accessories: Pipe screw fittings DIN : (please state purchaseno.) thread G/8 Pipe screw fitting with pipe outer diameter Check valve with pipe outer diameter G/ Bridges and lock screw: (please state purchaseno.) double without outlet (BB) triple without outlet (PPP) Bridges double with outlet (BA) triple with outlet (PPA) Bridges (location of the mid fastening screw "S") double without outlet (BB) triple without outlet (PPP) double with outlet (BA) triple with outlet (PPA) Lock screw "V" For mid fastening screw "S" position Page of 088 EN

6 Subject to modifications Main line Fig. Functional process fig.... : Monitoring of progressive distributors Leftside bypass line I II Rightside line bypass The lubricant flows from the main line through the rightside ring groove of piston III as well as the bypass line (right) and to the left side of piston I and moves it into its home position. The lubricant displaced by piston I is ejected via the left bypass line through outlet no.. As for instance due to soiling, the flow through a lubricant point line may be prevented. This will cause a piston to get blocked. By virtue of the forced control as depicted in figures up to, the other pistons will be stopped as well. Due to this configuration, the proportioning at all outlets of the distributor can be monitored by means of a sensor at one piston only. III Fig. Mounting note: I After shifting of piston I, lubricant flows to the left side of piston II and pushes it into its rightside home position. The displaced lubricant is ejected via outlet no.. The pistons are provided with an extremely small fitting clearance. Therefore, the pistons, after the dismantling of a distributor, must never be interchanged. Fig. Formula for calculating the lubricant available per lubrication point: After shifting of piston II, lubricant flows to the left side of piston III and pushes it into its rightside home position. The displaced lubricant is ejected via outlet no.. A progressive distributor allocates the delivered lubricant to the individual lubrication points in forced order. Due to the functional process as described herein, a safe proportioning is ensured. II The lubricant q i delivered to a lubrication point i can be calculated as follows Fig. q i = K i (K +K +K...) Q After shifting of piston III, lubricant flows to the right side of piston I and pushes it into its leftside home position. The displaced lubricant is ejected via outlet no.. The continuation of that process is evidenced in the scheme depicted. Q = lubricant delivered to the distributor, K i = distinctive number of the outlet i III Page of 088 EN

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-B

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Progressive distributor VPA-B Progressive distributor VPA-B Use: In progressive mode based central lubrication systems. The main features of WOERNER- progressive distributors are as follows: Accurate proportioning volumes. Clear and

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPA-D Progressive distributor VPA-D Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. Clear and

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim

EUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim Progressive distributor in element construction VPI-D Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: 4 different proportioning

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Progressive distributor VPB Progressive distributor VPB Use: In progressive mode based central lubrication systems. The main features of WOERNER progressive distributors are as follows: Accurate proportioning volumes. different proportioning

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use: Pump aggregate GMG-B Use: As pump aggregate in central lubrication systems for the delivery of oil, liquid grease or grease 1 or 2 pump outlets up to 2 outlets with progressive distributor flanged-on -

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Volume flow meter with throttle- and bypass valve KUZ-L

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Hafenstrasse 2 DE Wertheim. Volume flow meter with throttle- and bypass valve KUZ-L with throttle- and bypass valve Use: In oil lubrication systems H Viscosity-independent volume flow monitoring High measuring accuracy ig monitoring range Continuously adjustable volume flow Gearwheels

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim Reciprocating pump PMF / GMF This is a multi-line reciprocating pump for many applications - Subject to modifications - Being a universal type, our reciprocating pump is capable of meeting any challenge.

More information

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet...

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet... Table of contents 4 Technical basics System description... 04-0-10-01 Construction, applications, advantages, function System design... 04-0-10-02 Design and installation of progressive systems Calculation

More information

Progressive Central Lubrication Systems

Progressive Central Lubrication Systems Table of contents 4 Technical basics System description... 04-0-0-0 Construction, applications, advantages, function System design... 04-0-0-02 Design and installation of progressive systems Calculation

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E Pump unit GMZ-E Pump used to supply oil and grease from a barrel directly through a lid-hole or a bunghole. Technical data: Pump with bung-hole Pump with barrel lid Delivery volume per stroke: Pump element

More information

Progressive distributor SXE-2

Progressive distributor SXE-2 The progressive piston distributors SXE-2 are distribution units with hydraulic sequence control, whose pistons are controlled by the lubricant supply so that the lubricant is forced in sequence through

More information

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

Block metering device VPB. Block feeder for use in oil or grease lubrication systems Block metering device VPB Block feeder for use in oil or grease lubrication systems Block metering device VPB Block metering devices or feeders of the VPBM/VPBG series are used in small circulating-oil

More information

GREASE NLGI (*) OIL CST (*) PRESSURE (220.5) (147) - 20 (294) (220.5)

GREASE NLGI (*) OIL CST (*) PRESSURE (220.5) (147) - 20 (294) (220.5) CHARACTERISTICS THREE TYPES OF THREADING AVAILABLE: BSP, NPTF, SAE : UP TO 500 BAR : UP TO 400 BAR OIL AND GREASE FUNCTION CE AND ATEX MARKINGS BASES ALWAYS SUPPLIED WITH STANDARD SEALS AND MOUNTING SCREWS

More information

PROGRESSIVE BLOCK DISTRIBUTOR BVA-N

PROGRESSIVE BLOCK DISTRIBUTOR BVA-N PROGRESSIVE BLOCK DISTRIBUTOR BVA-N APPLICATION The BVA-N progressive block distributors are lubricating elements of central grease and oil lubricating systems. BVA-N series is made of stainless steel

More information

PROGRESSIVE DISTRIBUTOR PRA,PRB

PROGRESSIVE DISTRIBUTOR PRA,PRB PROGRESSIVE DISTRIBUTOR PRA,PRB APPLICATION PRA and PRB series Progressive distributors represent a lubricating element of central grease lubricating systems which are consequently known as circuits with

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

Progressive distributor MX-F

Progressive distributor MX-F The progressive piston distributors are distributor devices with a hydraulic sequence control, the pistons of which are regulated by the supplied lubricant in a way that the lubricant inevitably and successively

More information

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually. Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication

More information

Modular pneumatic valve unit

Modular pneumatic valve unit Modular pneumatic valve unit Compact design Modular configuration High flexibility Type 8640 can be combined with Simple exchange of valves (with option P-shut-off - also possible during operation) Type

More information

Progressive distributor SX-1

Progressive distributor SX-1 Progressive distributors SX-1 are distributor devices with hydraulic sequence control whose plungers of lubricant supplied are controlled such that the lubricant escapes forcibly and in sequence from the

More information

ZBD 1001 Differential Cylinder Data sheet 04.16/DS13210

ZBD 1001 Differential Cylinder Data sheet 04.16/DS13210 ZBD 1001 Differential Cylinder Data sheet 04.16/DS13210 Description: This series represents the logical and consistent supplementation of already ISO 6022 (250 bar) and ISO 6020/1 (160 bar) standard series.

More information

APPLICATION OF SYSTEM 8

APPLICATION OF SYSTEM 8 System 8 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures of all valve components is approimately

More information

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System Remote Process Actuation Control System AirLINE - Rockwell 1734 Type 8644 can be combined with... Fully compatible with Rockwell 1734 Point I/O System Combination of Fieldbus, pilot valves and I/O modules

More information

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits 2/2 way; DN 10-13 mm; 1 up to 7 bar Advantages / Benefits Reduction of Cost of Ownership up to 60% Modular system design Block assembly by lock technology Easy change between distributing and collecting

More information

Type KKP. Combination pumps

Type KKP. Combination pumps Features Compact and light Integrated low-pressure unloading valve and fail safe valve (not suitable for continuons rating) Can be started in maximum pressure mode Self-priming Direct installation of motor

More information

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems Electric barrel pump EFP- and EFPM- General, Fields of application und types of systems General: The - electric barrel pump EFP- is a precisionpiston pump designed for greases up to the consistency class

More information

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

Electric pump EP-1. Electric pump with 1.9 kg reservoir: The BEKA-MA central lubrication pump model EP-1 is electrically actuated and has up to a maximum of independently operating lubricant outlets. A separate pump element is required for each outlet. Three

More information

Modular pneumatic valve island

Modular pneumatic valve island Modular pneumatic valve island Compact design Modular configuration High flexibility Simple exchange of valves (with P shut off, also possible during operation an option) Type 8640 can be combined with

More information

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems 1-3029-EN Block feeder SPVS Used in oil or grease lubrication systems Block feeders of the SPVS series are used in grease and oil total loss lubrication systems. They are used to either increase the number

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Piston pump PMW. Air-actuated multiplunger pump

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Piston pump PMW. Air-actuated multiplunger pump PMW Air-actuated multiplunger pump Capable of delivering both oil and grease up to consistency class Use: - - As feed pump pneumatic drive As cycle-lubrication system in conjunction spraying nozzles Models:

More information

Modular multiple foot switches PC series

Modular multiple foot switches PC series 3B Modular multiple foot switches PC series Combination diagrams EMERGENCY PUSH BUTTON COMMERCIAL BOX ALUMINIUM PIPES CARRYING ROD ALUMINIUM PIPES HANDLE KIT STABILIZING PLATE DOUBLE CARRYING ROD COMMERCIAL

More information

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems 1-3029-EN Block feeder SPVS Used in oil or grease lubrication systems Block feeders of the SPVS series are used in grease and oil total loss lubrication systems. They are used to either increase the number

More information

BR 30a. Pneumatic Multi-turn Actuator. Application: Special designs:

BR 30a. Pneumatic Multi-turn Actuator. Application: Special designs: Pneumatic Multi-turn Actuator BR 30a Application: Single-acting pneumatic diaphragm multi-turn actuator for butterfl y valves and other rotary valves: The pneumatic BR 30a Multi-turn Actuators are diaphragm

More information

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems odular feeder PSG product series For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems PSG1 PSG2 PSG3 Fields of application etal-forming machinery

More information

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve)

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve) Table of contents Installation of the pump elements... 06-3-0-0 Functional description of the pump elements... 06-3-0-02 Overview pump elements... 06-3-0-03 with spring return PE 5 / PE 0 / PE 5 / PE 25

More information

External Gear Pumps Series F

External Gear Pumps Series F External Gear Pumps Series F RA 10089/08.11 Replaces: RA 10097 1/60 AZPF-... Fixed pumps Size 4.0...28 cm 3 /rev (.25-1.71 in 3 /rev) Overview of contents Contents Page General 2 Product overview 3 single

More information

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium: Settima screw a. Medium: HL oil conforming to DIN 51524 Parts 2 and 3 Special media such as: HFA min 5% oil HFB min 40% oil HFC max. 35-55% water HFDR high-viscosity lubricants SKYDROL, MIL-H may also

More information

Flow limiter SP/SMB 8... DSK US (09.04)

Flow limiter SP/SMB 8... DSK US (09.04) DSK 0-050-08-US (09.04) for mounting plates General information s are used in large oil circulation lubrication systems. The task of a flow limiter is to divide up the volumetric flow of the main line

More information

FITTINGS AND ACCESSORIES

FITTINGS AND ACCESSORIES INDEX Application examples and general notes... Page 2 General description... Page 3 Modular SMX SMX... Page 7 Monitor of piston movement: by a reed Switch and micro switch... Page 15 by inductive proximity

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Remote Process Actuation Control System AirLINE - Siemens ET 200S Remote Process Actuation Control System AirLINE - Siemens ET 200S Type 8644 can be combined with... Fully compatible with Siemens ET 200S Combination of Fieldbus, pilot valves and I/O modules High flexibility

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

MX-SERIES OVAL GEAR FLOW METERS

MX-SERIES OVAL GEAR FLOW METERS Data Sheet MX-SERIES OVAL GEAR FLOW METERS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MX-Series Oval Gear Flow Meters Features and Advantages P From ¼ DN8 at 0.5LPH to 4 DN100

More information

PMFO AIR/OIL SYSTEM PMFO AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS

PMFO AIR/OIL SYSTEM PMFO AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS AIR/OIL SYSTEM AIR-OIL PROGRESSIVE MODULAR LUBRICATING SYSTEMS (BLUE COLOUR ALUMINIUM BASE) The basic design of this system is similar to the PMF progressive, but with the inclusion of airways to enable

More information

AUTHORIZED DISTRIBUTOR DPX PROGRESSIVE DIVIDERS

AUTHORIZED DISTRIBUTOR DPX PROGRESSIVE DIVIDERS 1 DESCRIPTION Ilcolube is the lubrication system which identifies distribution and dosing with a progressive movement of pistons that are. Controlled one by the other in an interdependent sequence. This

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

M/44000/M. LINTRA Rodless cylinders Magnetic piston Double acting Ø 25 to 40 mm

M/44000/M. LINTRA Rodless cylinders Magnetic piston Double acting Ø 25 to 40 mm LINTRA Rodless cylinders Magnetic piston Double acting Ø 5 to 40 mm New compact, space-saving design Proven sealing system Integral switch mounting Adjustable cushioning Magentic piston as standard Technical

More information

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Flow limiter SP/SMB3 Flow limiter SP/SMB6 -00-EN Flow limiter SP/SMB Flow limiter SP/SMB6 for circulating-oil lubrication systems Advantages reliable perpetual dispensation of individual volume flows - self-adjusting metering, thus identical volume

More information

GRIPPERS SERIES P3 - P12 ACTUATORS

GRIPPERS SERIES P3 - P12 ACTUATORS GRIPPERS SERIES P3 - P12 1 GRIPPER WITH TWO PARALLEL JAWS, SERIES P3 GRIPPER WITH TWO PARALLEL JAWS, SERIES P3 Parallel double-acting two-jaw gripper, with either internal or external clamping. Body made

More information

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE

up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE up to size 381 up to PN 0.5 bar up to T = 80 C Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TSE 1. DESCRIPTION 1.1. GENERAL HYDAC fluid level gauges FSA, fluid level sensors FSK

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive

More information

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.

More information

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C 2/2-Way Function / Cavity conform to ISO 7368 (DIN 24342) Publ. 7 EN 5060 A FEATURES, DESCRIPTION FEATURES x High flow cartridges give highest

More information

Assembly and operating Instructions Bypass Flow Meter DST

Assembly and operating Instructions Bypass Flow Meter DST Assembly and operating Instructions Bypass Flow Meter 2 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions and exemption from liability... 3 2.3. Intended

More information

Modular multiple foot switches PC series

Modular multiple foot switches PC series 3 Modular multiple foot switches PC series Combination diagrams EMERGENCY PUSH BUTTON COMMERCIAL BOX ALUMINIUM PIPES CARRYING ROD ALUMINIUM PIPES HANDLE KIT STABILIZING PLATE DOUBLE CARRYING ROD COMMERCIAL

More information

Circulation pumps BFP-ATEX-T3/T4

Circulation pumps BFP-ATEX-T3/T4 Circulation pumps BFP-ATEX-T3/T F ATEX - range of use: to zone 1 and zone 1 T3 to zone 1 and zone 1 T Low noise emission High vol. efficiency Optimum suction Gerotor principle Resistant to contamination

More information

Chapter B-3. Chapter 3. Actuators and output devices. Festo Didactic TP101

Chapter B-3. Chapter 3. Actuators and output devices. Festo Didactic TP101 155 Chapter 3 Actuators and output devices Festo Didactic TP101 156 An actuator is an output device for the conversion of supply energy into useful work. The output signal is controlled by the control

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Rev. E Sept 06. VP300 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL

Rev. E Sept 06. VP300 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL CONTENTS 1 Introduction page 3 2 Specifications page 3 3 Part Description page 4 4 Operating Principles page 5 5 Operating Procedure 5-1 Setup page 6 5-2

More information

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES Product description Electric Lubrication pump Dynamis Maxx APPLICATION The DYNAMIS MAXX pump was designed and developed to serve as a multi-function automatic lubricant pump. Due to its compact size and

More information

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM020 series instruction manual ACCURATE FLOWMETERS & INSTRUMENTATION PVT. LTD. Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX Accurate Flowmeters & Instrumentation Pvt. Ltd.

More information

SKF Multilube pumping unit. for single-, dual-line and progressive lubrication systems

SKF Multilube pumping unit. for single-, dual-line and progressive lubrication systems SKF Multilube pumping unit for single-, dual-line and progressive lubrication systems SKF Multilube pumping unit The SKF Multilube pumping unit is an effective solution for lubricating individual machines

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3 .2 MEDIUM HEAVY DUTY SERIES SIZE 3 CONTENTS PGI101 Ordering Code.2.1 Medium Heavy Duty Series Technical Information.2.2 Specifications.2.3 Hydraulic fluids.2.4 Viscosity range.2. Temperature range.2.6

More information

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65. Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx

More information

Hydraulic pump HP-1. Type 1. Type 2

Hydraulic pump HP-1. Type 1. Type 2 The BEKA-MAX central lubrication pump model HP-1 is hydraulic actuated and has up to a maximum of independently operating lubricant outlets. A separate pump unit is required for each outlet. Three pump

More information

MAGNETO-INDUCTIVE POSITION DETECTORS

MAGNETO-INDUCTIVE POSITION DETECTORS MAGNETO-INDUCTIVE POSITION DETECTORS Series 88 Type 2 wires APPLICATION This four-wire proximity sensor will monitor stroke end and intermediate positions of pneumatic cylinders equipped with built-in

More information

Examples 3/2-way valve A T NO: Symbol

Examples 3/2-way valve A T NO: Symbol 1/1 Hauhinco-3_2-way valve_b1_dn3-25_pn320_pn500_x,y-intern water s 01/2016 3/2-way valve B1 X,Y - DN3 DN25 PN320, PN500 Features: Hydraulically actuated directional seat valve controlling liquid media.

More information

Flow limiter SP/SMB US

Flow limiter SP/SMB US Flow limiter SP/SMB 13... 1-3004-US for installation in the lines of circulating-oil lubrication systems General information Flow limiters are used in large circulating-oil lubrication systems. The task

More information

Manually or pneumatically actuated piston pumps

Manually or pneumatically actuated piston pumps Manually or pneumatically actuated piston pumps Product series Pxx For oil and fluid grease For use in SKF MonoFlex single-line centralized lubrication systems Manually or pneumatically actuated piston

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Orifice flowmeter F O N4

Orifice flowmeter F O N4 Special features Suitable for any mounting positions without reduction in accuracy Complies with requirements for treatment and disinfection of swimming/ bathing pools (DIN 9 643) Simple installation Direct

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines Valve seat lubrication Cylinder lubrication Version 04 Page 2 for cylinder lubrication and valve seat lubrication on

More information

DPL MONOBLOCK PROGRESSIVE DIVIDERS

DPL MONOBLOCK PROGRESSIVE DIVIDERS HIGH QUALITY HIGH TOLLERANCE 1. E L E A COMBINATION OF PERFORMANCE AND CONVENIENCE I.L.C. srl - Via Garibaldi, 149-21055 Gorla Minore Italy Ph. +39 0331 601697 Fax +39 0331 602001 - www.ilclube.com - info@ilclube.it

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Grease-lubricating pump FF... DSK US (05.05)

Grease-lubricating pump FF... DSK US (05.05) Grease-lubricating pump FF... DSK 2-008-00-US (05.05) electrically operated, for small and medium-sized multiple-line and progressive systems PSG-2 with cycle switch VPB with cycle switch PSG-2 with cycle

More information

Modular pneumatic valve unit

Modular pneumatic valve unit Modular pneumatic valve unit Compact design Modular configuration High flexibility Simple exchange of valves (with option P-shut-off - also possible during operation) Type 8640 can be combined with Type

More information

System 6. ü ( System 6

System 6. ü  ( System 6 System 6 ü www.nassmagnet.com ( +9 511 676-0 System 6 The name System 6 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings ISO 632 Cylinders ISO 15552 Cylinders Compact Cylinders TC08 Series Pilot Valves 207-208 209-212 213-21 215 TC15 Series Pilot Valves TC08 Series Solenoid Valves CD7 Series Solenoid Valves CD12 Series Solenoid

More information

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002 Proportional Directional Control Valves PRM7-6 HA 59 /6 Size D (6)...6 PSI ( bar)...6 GPM ( L/min) Replaces HA 57 / Digital control Compact design Operated by proportional solenoids High sensitivity and

More information

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013 Proportional Directional Control Valves PRM7-6 / Size 6 (D ) bar (76 PSI) L/min (.6 GPM) Replaces HA 7 / Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

Flow limiter SP/SMB9 for mounting plates

Flow limiter SP/SMB9 for mounting plates 1-3002-EN Flow limiter SP/SMB for mounting plates Advantages reliable perpetual dispensation of individual volume flows - self-adjusting metering, thus identical volume flows despite different back pressures.

More information

Instruction Manual EDS-75-S EDS-100-S/F EDS-160-S/F EDS-200-S/F EDS-220-Z EDS-250-S/F

Instruction Manual EDS-75-S EDS-100-S/F EDS-160-S/F EDS-200-S/F EDS-220-Z EDS-250-S/F Instruction Manual -75-S -100-S/F -160-S/F -200-S/F -220-Z -250-S/F -260-Z -300-S/F/Z -370-Z -400-S/F/Z -500-S -630-S/F Long-Stroke sensors, Series Contents 1. Safety... 5 1.1 Symbols Used... 5 1.2 Warnings...

More information

Modular electrical and pneumatic automation system

Modular electrical and pneumatic automation system Modular electrical and pneumatic automation system Decentralised automatisation without control cabinet in protection type IP65 / IP67 Modular structure, also as central station with several decentralised

More information

POSITIVE DISPLACEMENT FLOWMETERS

POSITIVE DISPLACEMENT FLOWMETERS MS589 0409 00 POSITIVE DISPLACEMENT FLOWMETERS M80 SERIES INSTRUCTION MANUAL M80 Pulse; Standard LCD; Deluxe LCD; From serial No.CXXXX TO THE OWNER Please take a few minutes to read through this manual

More information

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA > Series CST-CSV-CSH proximity switches Series CST - CSV and CSH magnetic proximity switches Reed, Electronic» Designed to fit into the grooves provided in the profile barrel of the cylinder» The three

More information

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05 Pressure transmitter Type Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement

More information

Control block VOFA with safety function

Control block VOFA with safety function Key features Innovative Versatile Reliable Easy to assemble Can be used for safe reversing of a hazardous movement (5/2-way solenoid valve) Can be used for safe venting (3/2-way solenoid valve function,

More information

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems. 1-3004-EN Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems. Flow limiters are used in circulating-oil lubrication systems. The task of a flow limiter is to divide up the

More information

4 Self aligning ball bearings

4 Self aligning ball bearings Rolling bearings 4 Self aligning ball bearings Designs and variants... 538 Basic design bearings... 539 Bearings with an extended inner ring.. 540 Cages... 540 Sealing solutions... 540 Greases for sealed

More information

Positive Displacement Flowmeters GM007 series instruction manual

Positive Displacement Flowmeters GM007 series instruction manual MS499G 0603 0003 Positive Displacement Flowmeters GM007 series instruction manual GM007 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM GPI by telephone or fax.] Series

More information

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line

ISO/VDMA Series ISO 6431 and VDMA Cylinder Line ISO/VDMA Series ISO 6431 and VDMA 24562 Cylinder Line www.asco.com Table of Contents ISO/VDMA Series Features and Benefits 2 How to Order 3 Technical Information 4 Dimensions Tie-Rod Version 5 Mounting

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

Flap-Type Flow Meter Prall

Flap-Type Flow Meter Prall Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional

More information