LOTOS Asfalt Sp. z o.o.

Size: px
Start display at page:

Download "LOTOS Asfalt Sp. z o.o."

Transcription

1 LOTOS Asfalt Sp. z o.o. Grupa Lotos SA Gdansk, Poland Page 1 of 45 Ruhrpumpen Project No: / Customer Project No: K214 Ruhrpumpen Project Code: Gdansk, Poland Customer Project Code: Ruhrpumpen Document No: Customer Doc. Control Code: A4207 Main Motor Drawing Wiring Diagram Main Motor Aux. Terminal Boxes Main Motor Drawing Main Terminal Box Main Motor Drawing VENDOR DOCUMENT REVIEW PROJ: CUSTOMER: MR N o : PO N o : K214 LOTOS Asfalt Sp. z o.o. K MR REJECTED 2 APPROVED WITH COMMENTS 3 APPROVED WITHOUT COMMENTS 4 FOR INFORMATION ONLY ITEM: 0960-X30 U.O.: KT S.p.A. VR Doc. CODE: A4207 BY: DATE: Arch No. Document No. Page Pages Rev. No B Issued for approval SIEMENS SIEMENS Jansen Rev. Stat. Description Date Prepared Date Checked Date Approved Status Codes: A B C D E Issued for information Issued for approval Preliminary issue Issued for quotation As-built Ruhrpumpen GmbH Stockumer Straße 28 D Witten, Germany Doc. No 2016 Ruhrpumpen GmbH Rev. No

2

3 Legend for machine Type of construction IM B3 / IM 1001 Degree of protection IP 56 non-heavy sea Method of cooling IC 611 Ambient temperature Total weight Weight of cooler housing C t 2.20 t The lifting points are designed to carry the weight of machine only. Lifting of machine together with base frame, adaptorplate or sole plates is not permitted! Weight of rotor t Balancing of rotor: dynamically balanced with half key without half-coupling DR = Direction of rotation (facing drive end DE) Counter-clockwise only LE = Air inlet LA = Air outlet SP = Center of gravity WA = Shaft extension DE XA = Relief groove DE = Lifting point BN = Probe for shaft vibration monitoring BENTLY-NEVADA KP = Keyphasor OZ = Oil inlet OA = Oil outlet Earthing connection 1 Terminal box for stator system connection Type 1XF6522-3AA Ident-No /010-M002

4 2 Terminal box for star point and current-transformer mounting Type 1XB Terminal box for auxiliary circuits Type 4 Terminal box for auxiliary circuits Type 1XB9015 1XB Separate terminal box for anti-condensation heater Type 1XB Indicator for bearing temperature monitoring 7 Terminal box for shaft vibration monitoring system Type 1XB Slide bearing DE Type EFiZLB Slide bearing NDE Type EFkZLB Air inlet silencer 15 Air outlet silencer 20 Monitoring system for scavenging air 21 Connection for scavenging air inlet 22 Valve for scavenging air outlet Ident-No /010-M003

5 Additional instructions for project work DR = Direction of rotation (facing drive end DE): The machine is only suitable for counter-clockwise direction of rotation. Counter-clockwise rotation: connection of the system phases L1 L2 L3 in the positive sequence of the machine terminals V U W. WA = Shaft extension DE Centering hole DR M30x63 XA = Relief groove DE E4x0.5 - DIN 509 Ident-No /010-M004

6 Earthing connection: max. admissible conductor cross-section with cable lug according to DIN46234 DIN mm mm 2 Ident-No /010-M005

7 1 Terminal box for stator system connection Type 1XF6522-3AA Manufacturer SIEMENS Degree of protection IP55 Type of protection for hazardous area Ex px Material Steel Cable entry (removable) not drilled Selection of cable glands and manufacturing of the tapped holes are in the responsibility of the customer! Cable entry made of non magnetic material Ident-No /010-M006

8 Ident-No /010-M007

9 Ident-No /010-M008

10 2 Terminal box for star point and current-transformer mounting Type 1XB9011 Manufacturer SIEMENS Degree of protection IP56 Type of protection for hazardous area Ex e Material Steel Cable gland 3x M25X1.5 Ø11-16 in removable cable entry Ident-No /010-M009

11 Current transformer Type Manufacturer EA10A_250/1_15VA/5P/10 MWB MESSWANDLER Attention! Operation with open secondary contacts is not permitted! Non connected secondary terminals of the current transformers have to be bridged and grounded! Non-observation can lead to personal injury, as well as to destruction of the current transformers! Ident-No /010-M010

12 Technical data of current transformers Ident-No /010-M011

13 Ident-No /010-M012

14 3 Terminal box for auxiliary circuits Type 1XB9015 Manufacturer STAHL Degree of protection IP66 Type of protection for hazardous area Ex e Material Stainless steel Plate for cable entry (removable) not drilled Selection of cable glands and manufacturing of the tapped holes are in the responsibility of the customer! max. admissible conductor cross-section 4 mm 2 Design with additional bar for connection of cable shields. The bar is installed insulated. Ensure that the shield of the cables is grounded on one side only! Not suitable for grounding of protective leads! Ident-No /010-M013

15 Ident-No /010-M014

16 Connections for auxiliary circuits: Embedded winding thermometer (resistance thermometer Pt100; 100Ω at 0 C) Quantity 6 Thermometers: Type of protection Ex ia Thermometers: Tolerance class A (IEC 60751) Thermometer with connection-no. in phase 21:1R1 U 21:2R1 V 21:3R1 W 21:4R1 U 21:5R1 V 21:6R1 W Guide values for adjustment of tripping temperature for embedded winding thermometers Initial adjustment before commissioning for disconnection T0 = 120 C Adjustment acc. to measured values for warning T1 = T + 10 K (max. 135 C) for disconnection T2 = T + 15 K (max. 140 C) Advice: T = Steady state temperature ( C) Attention: For monitoring of the winding temperature only the winding temperature sensors are suitable! Ident-No /010-M015

17 4 Terminal box for auxiliary circuits Type 1XB9015 Manufacturer STAHL Degree of protection IP66 Type of protection for hazardous area Ex e Material Stainless steel Plate for cable entry (removable) not drilled Selection of cable glands and manufacturing of the tapped holes are in the responsibility of the customer! max. admissible conductor cross-section 4 mm 2 Design with additional bar for connection of cable shields. The bar is installed insulated. Ensure that the shield of the cables is grounded on one side only! Not suitable for grounding of protective leads! Ident-No /010-M016

18 Ident-No /010-M017

19 Connections for auxiliary circuits: Bearing thermometer (double resistance thermometer Pt100; 100Ω at 0 C) Quantity per bearing 2 Type TR10-B with screw-in thermowell Manufacturer WIKA Thermometers: Design for current circuits Ex i The screen is grounded in the terminal box and must not be extended! Thermometers: Tolerance class A (IEC 60751) Guide values for adjustment of tripping temperature for bearing thermometers Initial adjustment before commissioning for disconnection T0 = 95 C Adjustment acc. to measured values for warning T1 = T + 2 K (max. 97 C) for disconnection T2 = T + 5 K (max. 100 C) Advice: T = Steady state temperature ( C) Cold air thermometer (double resistance thermometer Pt100; 100Ω at 0 C) Quantity 1 Type TR10-H Manufacturer WIKA Thermometers/Thermocouples: Design for current circuits Ex i The screen is grounded in the terminal box and must not be extended! Thermometers: Tolerance class A (IEC 60751) Guide values for adjustment of tripping temperature for cold air thermometer Initial adjustment before commissioning for disconnection T0 = 60 C Adjustment acc. to measured values for warning T1 = T + 10 K (max. 70 C) for disconnection T2 = T + 15 K (max. 75 C) Advice: T = Steady state temperature ( C) Ident-No /010-M018

20 Warm air thermometer (double resistance thermometer Pt100; 100Ω at 0 C) Quantity 1 Type TR10-H Manufacturer WIKA Thermometers/Thermocouples: Design for current circuits Ex i The screen is grounded in the terminal box and must not be extended! Thermometers: Tolerance class A (IEC 60751) Guide values for adjustment of tripping temperature for warm air thermometers Initial adjustment before commissioning for disconnection T0 = 90 C Adjustment acc. to measured values for warning T1 = T + 10 K (max. 100 C) for disconnection T2 = T + 15 K (max. 105 C) Advice: T = Steady state temperature ( C) Ident-No /010-M019

21 5 Separate terminal box for anti-condensation heater Type 1XB9015 Manufacturer STAHL Degree of protection IP66 Type of protection for hazardous area Ex e Material Stainless steel Plate for cable entry (removable) not drilled Selection of cable glands and manufacturing of the tapped holes are in the responsibility of the customer! max. admissible conductor cross-section 6 mm 2 Design with additional bar for connection of cable shields. The bar is installed insulated. Ensure that the shield of the cables is grounded on one side only! Not suitable for grounding of protective leads! Ident-No /010-M020

22 Stillstandsheizung Anti-condensation heating Typ/Type: 2NP9008 TBmax: 175 C V W PTB 02 ATEX 1157 IECEx PTB Ta: C 0102 II 2G Ex e IIC T3 Gb DEZ 9924 Ident-No /010-M021

23 6 Dial-type thermometer for bearing temperature monitoring, without contacts Quantity per bearing 1 Scale range C Diameter of housing 100 mm Degree of protection IP65 Manufacturer WIKA Type S5550 with screw-in thermowell Ident-No /010-M022

24 7 Terminal box for shaft vibration monitoring system Type 1XB9015 Manufacturer STAHL Degree of protection IP66 Type of protection for hazardous area Ex e Material Stainless steel Plate for cable entry (removable) not drilled Selection of cable glands and manufacturing of the tapped holes are in the responsibility of the customer! max. admissible conductor cross-section 4 mm 2 Design with additional bar for connection of cable shields. The bar is installed insulated. Ensure that the shield of the cables is grounded on one side only! Not suitable for grounding of protective leads! Ident-No /010-M023

25 Ident-No /010-M024

26 Shaft vibration monitoring system Type of housing with probe Type of cable Type of proximitor 3300XL Manufacturer BENTLY-NEVADA Quantity 4 Further details see technical instructions for operation and maintenance of manufacturer Recommended setting values for the shaft vibration S (p-p) [µm] Adjustment before commissioning Alarm 168 Disconnection 192 Adjustment in operating condition Alarm S (p-p) * Disconnection S (p-p) * Note: S (p-p) = measured basic value of the shaft vibration In addition the standard DIN ISO have to be considered generally! The values of shaft vibration and settings are applicable to steady-state operation. Higher values are permitted during the startup and coastdown phases. Suitable time-delay relays must be incorporated so that no warnings or trips are triggered during these phases. The time delay setting must be longer than the runup time. Ident-No /010-M025

27 BN Arrangement of the probes (facing shaft extension DE) Probe X Probe Y Probe X Probe Y left side right side left side right side DE NDE DE NDE Adjustment of probes Before commissioning the correct distance 1.3 ± 0.1 mm must be checked. Further details see technical instructions for operation and maintenance of manufacturer Ident-No /010-M026

28 KP Keyphasor Type of housing with probe Type of cable Type of proximitor 3300XL Manufacturer BENTLY-NEVADA Quantity 1 Arrangement of probe DE Adjustment of probe Before commissioning the correct distance 1.3 ± 0.1 mm must be checked. Further details see technical instructions for operation and maintenance of manufacturer Ident-No /010-M027

29 10 Slide bearing DE Manufacturer RENK Type of bearing EFiZLB Type of lubrication, type of oil and quantity of oil according to instructions or lubricating data plate Further details see technical instructions for operation and maintenance of manufacturer Delivery without oil! Lowest permissible oil temperature +5 C Bearing with indicator for magnetical center of axial rotor position Before the coupling is mounted, the rotor has to be set to its magnetical center. If the position of the pointer is over the middle of the marking on the shaft (as shown above), the axial clearance of the bearing is correctly adjusted. Due to production tolerances the axial clearance of the bearing can be somewhat larger than the indicated values. The bearing is installed insulated and insulation is bridged. Insulation bridge not disconnected during operation! Ident-No /010-M028

30 Schmieröl / Lubrication oil DIN CL 46 Viskositätsklasse / Class of viscosity ISO VG 46 Ringschmierung Ölinhalt Lager D-Seite ca. / D-end bearing apt. - l Oil ring lubrication nicht zulaessig Oil content Lager N-Seite ca. / N-end bearing apt. - l non-permissible - Öl-Volumen- Lager D-Seite / D-end bearing 4 l/min - strom Umlaufschmierung Oil-flow rate Lager N-Seite / N-end bearing 3 l/min Circulation oil lubrication Ölwechsel nur im Stillstand Oil changing during standstill only DEZ3070 Ident-No /010-M029

31 Oil connection DE OZ Oil inlet: OZ.1 Flange with orifice for limited flow rate OA Oil outlet: OA.1 Flange OA.2 Sight glass Additional oil sight glass (oil outlet) Type Manufacturer Oil inlet and oil outlet with counter flange Manufacturer Material ANSI-B16.5- ½ lbs - RF ANSI-B ½ lbs - RF DAT-2205HA40 KOBOLD AMV stainless steel Ident-No /010-M030

32 Consider the position of the orifice! (the arrow shows the oil-flow direction) Supplied orifice set (1 piece per diameter and bearing): Siemens number: A5E A5E A5E diameter: D = 1,8 mm (Q 3,6 l/min) D = 1,9 mm (Q 4,0 l/min) D = 2,0 mm (Q 4,4 l/min) Input data for calculation: Max. oil supply temperature: 50 C Ambient temperature: 40 C Class of viscosity: ISO VG 46 Oil supply pressure: 3 bar Ident-No /010-M031

33 Axial clearance of bearing The DE bearing is a floating bearing, the rotor of machine have to be axially restrained by a guide bearing in the driven machine or gearing. Therefore it is a requirement that only a coupling with a rigidly limited axial clearance (± ±1.0 mm) is provided! Floating bearing DE Floating bearing NDE 3,5 3,5 7 7 B10970 Ident-No /010-M032

34 11 Slide bearing NDE Manufacturer RENK Type of bearing EFkZLB Type of lubrication, type of oil and quantity of oil according to instructions or lubricating data plate Further details see technical instructions for operation and maintenance of manufacturer Delivery without oil! Lowest permissible oil temperature +5 C The bearing is installed insulated. Insulation shall not be bridged during operation! Ident-No /010-M033

35 Oil connection NDE OZ Oil inlet: OZ.1 Flange with orifice for limited flow rate OA Oil outlet: OA.1 Flange OA.2 Sight glass Additional oil sight glass (oil outlet) Type Manufacturer Oil inlet and oil outlet with counter flange Manufacturer Material ANSI-B16.5- ½ lbs - RF ANSI-B ½ lbs - RF DAT-2205HA40 KOBOLD AMV stainless steel Ident-No /010-M034

36 Consider the position of the orifice! (the arrow shows the oil-flow direction) Supplied orifice set (1 piece per diameter and bearing): Siemens number: A5E A5E A5E diameter: D = 1,5 mm (Q 2,5 l/min) D = 1,6 mm (Q 2,9 l/min) D = 1,7 mm (Q 3,3 l/min) Input data for calculation: Max. oil supply temperature: 50 C Ambient temperature: 40 C Class of viscosity: ISO VG 46 Oil supply pressure: 3 bar Ident-No /010-M035

37 20 Monitoring system for scavenging air Type F-361.C4M / ST-200 CM Manufacturer E.L.B. BACHMANN Rated voltage 230 V AC Connection: Clean, Dry, Oil Free Air or Inert Gas. Further details see technical instructions of manufacturer (The No. is equal to the type named above) Basic data for pre-purging and purging during operation final values see purging plate on the motor (plate designed after measurement, only) Pre-purging: Connection pressure min MPa Pre-purging volume min. 200 m³ Volumetric flow min 200 m³/h Time of pre-purging min. 60 min. Service: Leakage air rate max. 25 m³/h Overpressure at service min MPa Overpressure switch off MPa Ident-No /010-M036

38 21 Connection for scavenging air inlet Connection internal thread Rp 1 ½ Ident-No /010-M037

39 22 Valve for scavenging air outlet Type VA100-5 Ident-No /010-M038

40 General instructions All external screws made of non-corrosive material Increase of shaft height at operating temperature 0.24 mm Recommended setting values for the vibration velocity (RMS value, [mm/s]) Support class (foundation) rigid flexible Warning Adjustment before commissioning Adjustment in operating condition S x 1.25 S x 1.25 Disconnection Note: S = measured basic value of the vibration velocity Additionally the standard DIN ISO has to be considered generally! The value limits of vibration severity correspond to the vibration severity level B, according to DIN EN part 14 for rigid foundation, at a value of 1.5 mm/s. Painting system special paint finish acc. to TU-IK 030 Color RAL7035 Total thickness of coating 320 µm Ident-No /010-M039

41 Alignment accuracy for couplings: Consider the operating instructions of coupling manufacturer! Ident-No /010-M040

42 Fixation parts: 4 pc Shim (stainless steel) t = 2.00 mm 8 pc Shim (stainless steel) t = 1.00 mm 8 pc Shim (stainless steel) t = 0.50 mm 8 pc Shim (stainless steel) t = 0.25 mm 8 pc Shim (stainless steel) t = 0.20 mm 8 pc Shim (stainless steel) t = 0.15 mm 8 pc Shim (stainless steel) t = 0.10 mm 8 pc Shim (stainless steel) t = 0.05 mm 4 pc Fastening screw ISO 4017 / M42x120 - A pc Washer ISO 7091 / HV- A4 4 pc Jacking screw ISO 4017 / M36x100 - A pc Taper pin DIN 258 / 16x120 - Stainless steel Required tightening torque of the fastening screws M A = 1700 Nm (±15%) Ident-No /010-M041

43 Footprint (seen from below): Ident-No /010-M042

44 Instructions for transporting / lifting of machine The lifting points are designed to carry the weight of machine only. Lifting of machine together with base frame, adaptorplate or sole plates is not permitted! Ident-No /010-M043

45 Recommendation for spare parts Part Order-No. Slide bearing DE - Type EFiZLB Inner bearing seal DE A5E Outer bearing seal DE A5E Bearing shell DE A5E Lubrication ring DE Slide bearing NDE - Type EFkZLB Inner bearing seal NDE A5E Outer bearing seal NDE A5E Bearing shell NDE A5E Lubrication ring NDE Bearing thermometer DE Bearing thermometer NDE A5E A5E Ident-No /010-M044

ABB-TECHNICAL SPECIFICATION

ABB-TECHNICAL SPECIFICATION Document Reference ABB-TECHNICAL SPECIFICATION CG-58C-04-C017-060003 Revision 3.0 Status AFC Document Type SPE System / Unit 60 Discipline ELE Rev. Date 21-11-2013 Contractor Reference 3N911-3BSY200001-GRN

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding 4.4

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor INSTRUCTIONS Siemens Standard Motors Ltd. 2017.02 1.0 Overview 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor

More information

SINGLE PHASE TEFC CAGE MOTORS

SINGLE PHASE TEFC CAGE MOTORS SINGLE PHASE TEFC CAGE MOTORS 2 SINGLE PHASE TEF CAGE MOTORS Mechanical protection: IP 54 Voltage: 220 V, 50 Hz Type Output power P N kw Rated speed n N min -1 Efficiency % Power factor cos Rated current

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

Resistance thermometer Model TR10-E, for additional thermowell

Resistance thermometer Model TR10-E, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection Electrical temperature measurement Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection WIKA data sheet TE 60.26 Applications Sanitary applications Food and beverage

More information

Resistance thermometer Model TR10-B, for additional thermowell

Resistance thermometer Model TR10-B, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-B, for additional thermowell WIKA data sheet TE 60.02 Applications Machine building, plant and tank construction Energy and power plant

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Low-Voltage Motors N-compact Standardline Operation on supply system

Low-Voltage Motors N-compact Standardline Operation on supply system Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More

More information

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Gas-actuated thermometer with switch contacts Stainless steel version Model 73 Temperature Gas-actuated thermometer with switch contacts Stainless steel version Model 73 WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation of industrial processes

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35 Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35 WIKA Data Sheet TE 60.03 Applications Machinery, plant and tank construction Energy

More information

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell Electrical Temperature Measurement Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell WIKA Data Sheet TE 60.15 Applications T Machinery, plant and tank construction T Energy

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding and Insulation

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

Plain Bearing Technology. ZF end flange mounted bearing

Plain Bearing Technology. ZF end flange mounted bearing Plain Bearing Technology ZF end flange mounted bearing Description of the ZF design 02 // 03 The ZOLLERN Group ZOLLERN is one of the pioneers of the metal industry. 3,000 employees at 15 production locations

More information

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Gas-actuated thermometer with switch contacts Model 73, stainless steel version Mechatronic temperature measurement Gas-actuated thermometer with switch contacts Model 73, stainless steel version WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation

More information

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2 Marine Motors Three Phase Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES 63-400 SIZES MarelliMotori ASI.CT.033.2 CONTENTS Page STANDARDS 5 ESSENTIAL AND NON-ESSENTIAL SERVICE 5 CLASSIFICATION

More information

Type MR 783 Magnetic level switch

Type MR 783 Magnetic level switch Technical data sheet Magnetic level switch Houdec Instrument SAS Magnetic level switch Technical data sheet Page 0 Technical data sheet Magnetic level switch Operation A float fitted with a magnet slides

More information

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74 Temperature Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74 WIKA data sheet TV 27.02 Applications Food industry Sanitary applications Bio and pharmaceutical

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2) ANNEX No 1 DRAWINGS Drawing No. Drawing Description Revision Date Ex e, na and td SGA100A General Arrangement for SGA 71 frame motor C 16/06/2006 SGA101A General Arrangement for SGA 80-132 frame motor

More information

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B Resistance Thermometers according to DIN Ignition Protection Exia measuring monitoring analysing TWL-Exia O O Measuring range: -...+600 C OO Pt 100-sensor class A respectively class B OO Output: resistance

More information

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6 Data sheet Item no.: Page: 1 / 6 Operating data Operating data determined for maximum inlet pressure Pumped medium Water Clean water Not containing chemical and mechanical substances which affect the materials

More information

Measuring insert for resistance thermometer Model TR10-A

Measuring insert for resistance thermometer Model TR10-A Electrical temperature measurement Measuring insert for resistance thermometer Model TR1-A WIKA data sheet TE 6.1 for further approvals see page 6 Applications Replacement measuring insert for servicing

More information

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls www.atos.com Table A600/E Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls PVPCCH4046 PVPC are variable displacement axial piston pumps for high pressure operation,

More information

K - Flow Meter with Float

K - Flow Meter with Float K - Flow Meter with Float Doc. no.: 18, en_cat_k, 12/2014, rev. 1 Application All-metal flow meters with float type K are used for signaling and measuring of instant flow, flowed volume of liquid and fluent

More information

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact: Qty. Description 1 2L Product No.: 81U1332 The motor is a 3-phase AC standard motor. Installation: Range of ambient temperature: -2.. C Flange size for motor: FF Note! Product picture may differ from actual

More information

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications

More information

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 SQL33 Electromotoric Actuators for valves with 90 angle of rotation SQL33 operating voltage AC 230 V SQL33 operating voltage AC 230 V operating voltage AC 24 V 3-position control signal Nominal angle

More information

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/. 1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:

More information

Resistance thermometer with digital indicator Model TR75, battery operation

Resistance thermometer with digital indicator Model TR75, battery operation Electrical temperature measurement Resistance thermometer with digital indicator Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information (E) Atmospheres containing explosive GAS General information Flameproof totally enclosed three-phase asynchronous motors, FLSD (E) series, according to IEC 60034, 60038, 60072, 60079-0 and 60079-1, EN

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Series E4F E5F

Series E4F E5F Three Phase Induction Motors With Rotors Wound for Hoists Series E4F 160-315 E5F 355-400 ASI NT 003.1 I N D E X Use 2 Electrical Tolerances 9 Mechanical Tolerances 9 General Characteristics 2 Technical

More information

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na M3000 Motors for Hazardous Areas Low Voltage Non-sparking Motors Ex na, EEx na Non-sparking EEx na, Ex na, Ex N Range Standards Frame Size Output range Non-sparking Ex na IEC 60079-15 aluminium 90-250

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS FOR USE WITH THERMOWELLS II 1G/D Ex ia Pt100RI/WI S10 S11 S16-1 S16-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright 212 ABB TECHNICAL

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

Control Valve fluids with integrated positioner. GS 3 series - DN 15 up to DN 250. material

Control Valve fluids with integrated positioner. GS 3 series - DN 15 up to DN 250. material Control Valve 8021 with integrated positioner GS 3 series - DN 15 up to DN 250 Pneumatic control valve for the control of neutral and aggressive fluids with integrated positioner Space saving wafer type

More information

External gear pump Series G

External gear pump Series G External gear pump Series G RE 10 093/04.14 Replace RE 10 093/06.13 AZPG-22 Fixed pumps V = 22.5...100 cm 3 / rev Overview of contents Contents Page General 2 Product overview 3 Ordering code single pumps

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright 212 ABB TECHNICAL

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Standard cast iron Motor

Standard cast iron Motor Standard cast iron Motor Frame size 80 to 355 Série 1L Phase 3 Voltage 265/460V 60Hz Types of mounting B3 V9 B5 B14 B6 B9 B3 / B5 V5 B3 / B14 B15 V1 B7 V18 V1 / V5 V8 V18 / V5 V6 B8 V3 / V6 V3 V19 V19

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

3/2-way Rocker Solenoid Valve for pneumatic systems

3/2-way Rocker Solenoid Valve for pneumatic systems 3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted

More information

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs Gear Motors Series PGM Fixed Displacement Motors, Aluminium Designs aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

PLAIN BEARING TECHNOLOGY PLAIN BEARINGS TYPE ZR/ ZG

PLAIN BEARING TECHNOLOGY PLAIN BEARINGS TYPE ZR/ ZG PLAIN BEARING TECHNOLOGY PLAIN BEARINGS TYPE ZR/ ZG The ZOLLERN Group ZOLLERN GmbH & CO. KG is a company with world wide operations, employing over 3000 employees in the business fields of transmission

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J Electrical temperature measurement Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J WIKA data sheet TE 60.10 for further approvals see page 7 Applications Ventilation

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 further approvals see page 11 Applications For direct installation into the process Machine building

More information

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280

More information

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A Temperature Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A WIKA data sheet TE 60.22 for further approvals see page 15 Applications Sanitary applications Food and beverage

More information

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor WIKA data sheet TE 60.22 for further approvals see page 14 Applications Sanitary applications

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

Measuring insert for process resistance thermometer

Measuring insert for process resistance thermometer Electrical temperature measurement Measuring insert for process resistance thermometer Model TR12-A WIKA data sheet TE 60.16 for further approvals see page 2 Applications Replacement measuring insert for

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building

More information

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw CEB 71204/a of 13 december 2005 SLSHR 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw C.E.B. SLSHR RANGE TECHNICAL CATALOGUE 05/12/13 CONTENTS CONTENTS 2 APPLICATIONS

More information

champion series motors

champion series motors Introducing A brand new series of Super Performers Data Sheet champion series motors FRAME SIZE 63-132M TEFC 3 Phase Squirrel Cage Induction Motors Siemens CHAMPION Series Cage Motors are suitable for

More information

Slide Bearings Type EM 9S For Shaft Diameters 80, 90, 100 mm Main Application Field Electric Machines

Slide Bearings Type EM 9S For Shaft Diameters 80, 90, 100 mm Main Application Field Electric Machines Slide Bearings Type EM 9S For Shaft Diameters 80, 90, 100 mm Main Application Field Electric Machines Centre flange mounted slide bearing type EM 9S The RENK EM 9S bearing is a fully self-contained, centre

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40 Mechatronic pressure measurement Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40 WIKA data sheet PV 17.19 Applications weitere Zulassungen

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry. Low-voltage motors up to 315kW 1LG0 Low-voltage Motors Answers for industry. 1 Low-voltage squirrel-cage motors 4 Motor standard 4 Standard 5 Condition 5 Mechanical design 5 High quality performance 5

More information

Norm-Centrifugal Pumps PN 10

Norm-Centrifugal Pumps PN 10 Norm-Centrifugal Pumps PN 10 Pump dimensions acc. to DIN EN 733 with additional sizes Technical requirements acc. to DIN ISO 9908 Application For pumping pure water, industrial water, sea water, condensate,

More information

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR MINING ELECTRIC MOTORS 3KTCR AND 4KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280 Frame

More information

EIPC3 EIPC5 EIPC6. Internal gear pumps. eckerle.com

EIPC3 EIPC5 EIPC6. Internal gear pumps. eckerle.com EIPC3 EIPC5 EIPC6 Internal gear pumps eckerle.com Internal gear pump Type EIPC3 for industrial applications with constant displacement volume EIPC3 Characteristics Internal gear pump with axial and radial

More information

Axial Piston Fixed Pump A17FNO Series 10

Axial Piston Fixed Pump A17FNO Series 10 Axial Piston Fixed Pump A17FNO Series 10 RE 91510 Issue: 06.2012 Replaces: 03.2010 Size 125 Nominal pressure 250 bar Maximum pressure 300 bar For commercial vehicles Open circuit Features Fixed pump with

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

Differential pressure gauge Model , copper alloy Model , stainless steel version

Differential pressure gauge Model , copper alloy Model , stainless steel version Mechanical pressure measurement Differential pressure gauge Model 712.15.100, copper alloy Model 732.15.100, stainless steel version WIKA data sheet PM 07.29 Applications for further approvals see page

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN

More information

New Generation 1LE1/1PC1

New Generation 1LE1/1PC1 New Generation LE/PC /2 Orientation /2 Overview /3 Benefits /4 Application /4 Technical specifications /5 Selection and ordering data /7 More information /8 General Line motors with shorter delivery time

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information