WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY
|
|
- Junior Marshall
- 5 years ago
- Views:
Transcription
1 Instruction Manual HBDF MK2 Defrost Sensor For automatic defrosting of evaporators Simple Setup, only two parameters and execution of a zero/start point during start-up. instruction manual - HBDF mk2 defrost sensor (005-UK) 1 / 14
2 Table of Contents Instruction Manual... 1 HBDF MK2 Defrost Sensor... 1 For automatic defrosting of evaporators... 1 Table of Contents... 2 Safety Instructions... 3 Introduction... 4 Measuring Principle... 5 Design... 5 Software... 5 Technical Data... 6 Function... 7 Installation Instructions... 8 HBDF-snapON Clips... 8 Parameter settings... 9 Electrical connection Application examples Simple defrost with electric heater LED Indication and Calibration LED indication Fault Detection Sensor Repair Spare Parts Further Information instruction manual - HBDF mk2 defrost sensor (005-UK) 2 / 14
3 Safety Instructions CAUTION! Always read the operational guidelines before commencing work! Read all warnings Installation of HBDF requires technical knowledge of both refrigeration and electronics. Only qualified personnel should work with the product. The technician must be aware of the consequences of an improperly installed sensor and must be committed to adhering to the applicable local legislation. If changes are made to type-approved equipment, this type approval becomes void. The product's input and output, as well as its accessories, may only be connected as shown in this guide. HB Products assumes no responsibility for damages resulting from not adhering to the above. Explanation of the symbol for safety instructions. In this guide, the symbol below is used to point out important safety instructions for the user. It will always be found in places in the chapters where the information is relevant. The safety instructions and the warnings in particular, must always be read and adhered to. CAUTION! Refers to a possible limitation of functionality or risk in usage. NOTE! Contains important additional information about the product and provides further tips. The person responsible for operation must commit to adhering to all the legislative requirements, preventing accidents, and doing everything so as to avoid damage to people and materials. Intended use, terms of use. The HBDF defrosting sensor is designed for measuring ice formation on evaporators. If the HBDF is to be used in a different way and if the operation of the product in this function is determined to be problematic, prior approval must be obtained from HB Products. Defrosting with hot gas must be performed in a safe way in order to ensure that there is no risk for liquid hammering and leakage of refrigerant. Preventing collateral damage: Make sure that qualified personnel assess any faults and take necessary precautions before attempting to make replacements or repairs, so as to avoid collateral damage. Disposal instructions: HBDF is constructed so that the modules can easily be removed and sorted for disposal. instruction manual - HBDF mk2 defrost sensor (005-UK) 3 / 14
4 Introduction HBDF is an intelligent sensor with a built-in microprocessor. It is designed to measure ice formation on evaporators (Air-Coolers). It emits a 4-20 ma signal. Apart from the 4-20 ma signal, the sensor also has built-in relays for start/stop defrost and external temperature sensor for measuring when the ice is melted. Example showing the HBDF MK2 configuration tool Enable start / stop input, set to ON Disable relay out Start defrost, 50% = 1.5mm Defrost stop temperatur Frost mode delay Simple calibration, only use these two parameters. Active wire length Distance between fins Setup is very simple, only two parameters and execution of a zero/start point and a Calibration with frozen/dry evaporator surface (surface with thin layer of frozen ice as after defrost is the optimal start point). The length of the wire entered is only the wire between the fins, and not the free wire in the bending. instruction manual - HBDF mk2 defrost sensor (005-UK) 4 / 14
5 Measuring Principle The sensor is a capacitive sensor. The capacitive measurement principle is based on the electrical properties in the proximity of a capacitor. A capacitor is an electrical component that is capable of building and retaining an electrical charge. A capacitor basically consists of two plates. When a charge is applied to one plate, the other plate will be charged with the opposite polarity and retain the charge until it has been grounded. The magnitude of the charge that can be generated (the capacitance) depends, among other things, on what is found between the plates. The substance between the plates is referred to as a dielectric. Rather than two plates, sensors for level measurement are usually shaped as cylindrical rods. When liquid covers the sensor, the measured capacity is changed. The conductivity of a material can vary depending on temperature, chemical composition, and the homogeneity of the material, and therefore it can require a different factory calibration in some cases. Sensors from HB Products are calibrated so that they differentiate between conductive and non-conductive liquids. In refrigeration systems, oil and liquid CO 2 and HFC are not regarded as conductive fluids, whereas refrigerants such as ammonia and brine are regarded as conductive fluids. Design The sensor consists of a mechanical part (wire) and an electronic part. These can easily be separated by loosening the cover on the electronic box. The electronic part is designed in accordance with IP65 waterproof rating, heater and to resist vibrations. Software The sensor is delivered with the latest firmware. The sensor can be set up with a configuration tool, "HB Tool", by using a PC. Once you are online and connected to the program the software will be automatically ask for update. The newest version of the tool is backwards compatible. instruction manual - HBDF mk2 defrost sensor (005-UK) 5 / 14
6 Technical Data Supply voltage: Electricity consumption: Electrical connection: Analogue output: Max. load: Relay output: Relay output 24V: Installation conditions: Ambient temperature: Waterproof rating: Vibrations: 24 V AC/DC 600 ma Screw terminals 4-20 ma 500 ohm 2 x 5A, NO/NC 2 x 3A, NO/NC C IP65 IEC (4g) Certifications: EMC Emission: EMC Immunity: EN EN Mechanical specifications: Materials mechanical parts: AISI304 Materials electronic parts: Nylon 6 (PA) Configuration & indication: Configuration with push button Configuration PC with HB-TOOL LED Indication green, and red Cable entry: PG9 / M12 Note! All terminals are protected against improper termination for a supply voltage up to 40 V. If the supply voltage is higher than 40 V, the electronics will be damaged. instruction manual - HBDF mk2 defrost sensor (005-UK) 6 / 14
7 Function HBDF measures the build-up of ice between the fins of the evaporator. The sensor is installed and calibrated for the currently installed evaporator. At start-up, it is usually enough to perform the simple start up procedure as shown in the introduction section. Graphical view of a typical sequence on an air cooler: Advanced Calibration: The calibration should be carried out before ice begins to build up. When the evaporator is free of ice, the sensor emits 4mA. Depending on the ice build-up, the sensor emits up to 20mA or 18mA (when set to ma only mode). A visual inspection must be carried out to determine when defrost should be performed, and the system s defrost control (PLC) should be set to perform defrost at that given signal level (for example 12 ma). Defrost must be stopped when outside coil temperature is above 5 to 10 C. After fan delay where remaining water droplets from the melted frost is frozen to the surface of the evaporator, here the signal is 4 to 5mA indicating clean evaporator without ice. The built-in relays can be used to activate simple defrost control or digital input to an external defrost controller (Replace a timer) instruction manual - HBDF mk2 defrost sensor (005-UK) 7 / 14
8 Installation Instructions The following applies to system design: 1) The sensor box is installed on the evaporator s frame. 2) Ground wire should be connected to the frame with a stainless screw. 3) The wire is installed between the fins, where ice build-up occurs, the wire could be fixed with a special HBDF wire-clips or standard nylon (PA6) wire strips. 4) Normal installed with a standard unshielded cable. If the EMC is higher than described in EN 61326, a shielded cable must be used. Note: To have a good rigid ground connection, we recommend using stainless screw with a star washer/disc and cover/applying silicone grease/compound around the connection to avoid corrosion. HBDF-snapON Clips Not included The active part of the wire is the length between the fins. The wire must be placed between the fins, the distance of each can be freely chosen between 100 to 500mm depending on evaporator size and wire length. instruction manual - HBDF mk2 defrost sensor (005-UK) 8 / 14
9 Parameter settings Parameter Enable Start/Stop function Enable ma only function Defrost Start in % Defrost stop temp. Sensor delay in min. Sensor lenght in mm. Distance between fins in mm. Description Activate/deactivate the measuring and set the ma output to 4mA, and set the digital relays to default. Turn off the digital relays and also the timers. Only running with ma output. Defrost start in % where the digital start relay is activated and the ma is lock when it get to the defrost start level. E.g. 50% stops the ma output at 12mA. Defrost stop temperature when the digital stop relay is activated and the sensor delay starts running. Sensor delay is used for the time after defrost before the sensor is activating the measuring again. The start and stop relay is deactivated after timeout. The total length of the wire between the fins. Distance between fins in mm. CAUTION! In case of welding on the system, disconnect the power supply so that the electronics are not damaged during welding. instruction manual - HBDF mk2 defrost sensor (005-UK) 9 / 14
10 Electrical connection The HBDF MK2 sensor measures ice formation on evaporators (Air-Coolers). It emits a 4-20 ma signal. Apart from the 4-20 ma signal, the sensor also has built-in relays for start/stop defrost and external temperature sensor for measuring when the ice is melted. Should normally be used with a master defrost controller or a PLC, simple defrost with electric heater can be controlled directly as shown in application on page 11. instruction manual - HBDF mk2 defrost sensor (005-UK) 10 / 14
11 Application examples Safety: Defrosting with hot gas must be performed in a safe way in order to ensure that there is no risk for liquid hammering and leakage of refrigerant. instruction manual - HBDF mk2 defrost sensor (005-UK) 11 / 14
12 Simple defrost with electric heater The HBDF-MK2 sensor is primarily designed to measure ice thickness where the analogue 4-20mA output indicates the ice thickness, the built-in relays are usually used for start and stop signal of an external defrost timer or controller. Simple defrost with electric heater and adjustable fan delay is possible. LED Indication and Calibration instruction manual - HBDF mk2 defrost sensor (005-UK) 12 / 14
13 LED indication 1) Green LED, flash indicates power supply, And DI external start signal is ON. 2) Red LED indicates Defrost mode or sensor error (Outside measuring range). LED signal ON/OFF/Frequency Functionality Green On or flash Supply voltage connected Flash (Run-In mode) Run-in start signal / operation. OFF No supply voltage Red Flash Defrost mode start Flash quickly Defrost mode stop OFF Defrost fan/sensor delay (timer end) Fault Detection Fault Reason Correction of fault No LED is on / no function No supply to the sensor or defective cable. Check for fault in the power supply or replace the supply cable. Red LED are flashing Power supply is too small. Install a power supply with a capacity of at least 30 W. No AO, ma output or Relay There may be bad ground connection Clean the metal surface and protect it contact activation to the frame. with special compound/grease. Practical measurement of output signals: 4-20 ma signal: Function and stability of the 4-20 ma signal can be checked by connecting a hand-held multimeter. If the supply is connected and the power LED flashes and there is no output signal, the electronics may be defective. instruction manual - HBDF mk2 defrost sensor (005-UK) 13 / 14
14 Sensor Repair In case of defects with the sensor, it will typically only be necessary to replace the electronical part. Complaints are processed by HB Products dealers/distributors. Please consider their complaint procedures before returning the sensor. Spare Parts Position Designation Specification Product number 1 Mechanical part 10 m wire HBDF-MEK-10M Mechanical part 20 m wire HBDF-MEK-20M Mechanical part 30 m wire HBDF-MEK-30M 2 Electronic part PCB HBDF-MK2-EL 3 Temp. sensor Pt1000-Cable type HBPT-Pt1000 cable 4 Communication cable HB USB cable HBxC-USB Further Information For further information, please visit our website, or send an to: support@hbproducts.dk. HB Products A/S Bøgekildevej 21 DK8361 Hasselager support@hbproducts.dk instruction manual - HBDF mk2 defrost sensor (005-UK) 14 / 14
HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems
Instruction manual HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems Instruction manual HBLT-wire Levelsensor (006-UK) 1 / 11 Table of contents Safety Instructions...
More informationHBSC2 CO 2 switch. Instruction manual. For detecting liquid CO 2 in refrigeration systems
Instruction manual HBSC2 CO 2 switch For detecting liquid CO 2 in refrigeration systems Instruction manual HBSC2 Refrigeration Switch (HBSC2-006-UK) 1 / 13 Table of contents Safety Instructions... 3 Introduction...
More informationHBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY
Instruction manual HBSO1 Oil switch For detecting oil in refrigeration systems Instruction manual HBSO1 Oil Switch (HBSO1-003-UK) 1 / 14 Table of contents Safety Instructions... 3 Introduction... 4 Measurement
More informationHBOC - OIL MANAGEMENT
Instruction manual HBOC - OIL MANAGEMENT For oil level control / compressor protection & control of oil returned from the oil separator Instruction manual - HBOC Oil Management (HBOC-005-UK) 1 / 20 Table
More informationHBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems
Instruction Manual HBLT-C1 Controller For pump control of levels in industrial refrigeration systems Instruction manual HBLT-C1 Controller (006-UK) 1 / 14 Table of Contents Safety Instructions... 3 Introduction...
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More informationContinental Hydraulics Installation Manual CEM-AA-A
Continental Hydraulics Installation Manual CEM-AA-A Description: This power amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to proportional
More informationELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS
ELECTRIC FENCE ENERGIZER MODEL 950 SERVICE MANUAL Service Manual for OLLI 950 Page 1/16 Date 20.10.2014 Table of Contents...1 1. IMPORTANT SAFETY INSTRUCTIONS...2 2. SPECIFICATIONS...3 3. CONSTRUCTION...4
More informationfluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface
fluid technology temperature sensors 1600 1 dimensions Ø38 x 118mm temperature operating range -40 to +300 C temperature measuring range from -40 to +300 C M12 socket for PT100 resistance thermometer analog
More informationOperating Manual. D3D Innovations Limited. 7 Kings Road, Wrington, Bristol, BS40 5LW, UK.
Operating Manual FILAMENT WINDER D3D Innovations Limited 7 Kings Road, Wrington, Bristol, BS40 5LW, UK www.filafab.co.uk www.d3dinnovations.com www.filafab.co.uk Copyright 2016 by D3D Innovations Limited
More informationHUMIDITY / TEMPERATURE TRANSMITTER
HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY
More informationTechnical Documentation
Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that
More informationActive Controlled Cooling System
Active Controlled Cooling System April 2011 3267 Progress Dr Orlando, FL 32826 www.apecor.com Preliminary www.apecor.com Table of Contents General Information... 3 Safety... 3 Introduction... 3 What s
More informationAdjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry
Adjustable PT100 Bearing Temperature Sensor with ½ NPT Conduit Entry Hot bearing WARNING device, for use in hazardous areas Installation guide PT100V3C Bearing Temperature Sensor With Grease nipple 1/2
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationINTECH Micro 2300-RTD6
INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent
More informationInduction Power Supplies
Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.
More informationHGM1750 Genset Security Module USER MANUAL Smartgen Technology
HGM1750 Genset Security Module USER MANUAL Smartgen Technology CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 5 3. SPECIFICATION... 7 4. OPERATION... 8 5. PROTECTION... 9 6. PARAMETER RANGE
More informationKeContact P20. User manual
KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially
More informationINSTRUCTION & INSTALLATION
INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,
More informationAir Handling Units. Geniox. Accessories
Air Handling Units Geniox Accessories The right accessories are important to optimise your Geniox air handling unit to the task at hand. SystemairCAD provides you with a wide selection of accessories.
More information- Wiring Brochure Mixing Expansion Module 440
- Wiring Brochure Mixing Expansion Module 440 W 440 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationSolenoid Valve DF-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve DF-SA-series The DF-DA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. These valves have an orifice of 16 to
More informationECONOMISER SERIES E2T USER MANUAL
TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014
More informationEASY CHARGE Waterproof portable Battery Charger
EASY CHARGE Waterproof portable Battery Charger 1.1 AND 4.3 AMP MODELS EN NL, DE, FR, ES, IT USER S MANUAL WWW.MASTERVOLT.COM/EASYCHARGE-PORTABLE 10000009117/04 2 EN / EasyCharge 1.1 and 4.3 Amp - User
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationapprovals ATEX/IECEx
approvals ATEX/IECEx Designed for Refrigeration by Refrigeration engineers HBPs Long Stroke and Short Stroke position sensors are designed for stepless Capacity/Volumen control on Screw Compressors, where
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationCLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16
User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...
More informationINSTALLATION USER MANUAL
INSTALLATION & USER MANUAL DYNAMIC LOAD MANAGEMENT -PREMIUM- This document is copyrighted, 2016 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to
More informationMCD Pump Application Module
Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital
More informationKelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.
Kelly HSR Opto-Isolated Series Motor Controller with Regen User s Manual HSR72601 HSR72801 HSR12401 HSR12601 HSR12901 HSR14301 HSR14501 HSR14701 Rev.3.3 Dec. 2011 Contents Chapter 1 Introduction... 2 1.1
More informationILED Aquarius Illuminated Windsock. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...
More informationATOTH-G Series BLDC Motor Controller. User s Manual
ATOTH-G Series BLDC Motor Controller User s Manual Contents Chapter One Summary...1 Chapter Two Main Features and Specifications.2 2.1 Basic Functions...2 2.2 Features... 5 2.3 Specifications...6 Chapter
More informationModel H30 Operation Manual
Model H30 Operation Manual Model H30 Version 1.0 August 1, 2007 2 135 West Davenport Street Rhinelander WI 54501 Phone: 866.441.7997 Fax: 866.278.0036 info@houstonst.com www.houstonst.com 3 Table of Contents
More informationOPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets
Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599
More informationElectronic Ballast EVG 2000-T
Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications
More information- Wiring Brochure Zone Manager 335
- Wiring Brochure W 335 12/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications Rough-in Wiring Rough-in wiring instructions 3 4 Wiring
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationSupport. EMROL Your power partner
Support Support Part one What is and how to use / upgrade the software / firmware / manual How to start a capacity test Interpreting the results after a test is finished Read out the results with the BITS-software
More informationKelly KDC Series/PM Motor Controller User s Manual
Kelly KDC Series/PM Motor Controller User s Manual KDC48600 KDC48601 KDC48602 KDC48603 KDC72600 KDC72601 KDC72602 KDC72603 KDC72800 KDC72801 KDC72802 KDC72803 KDC12602 KDC12603 Rev.3.3 May 2011 Contents
More informationVideo & Power Over Coax Kit
VPoC User Manual Video & Power Over Coax Kit 1CH Video Power over Coax w/ 12V DC Receiver Device VPoC24DC-01K VPoC24DC-01 N-42-1 x1 N-41C 4CH / 8CH / 16CH Video Power over Coax Server Kit VPoC24DC-04K
More informationHGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology
HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951
More informationInverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.
Inverter / Charger Accessory for Steca Solarix PLI 5000-48 3-Phase / Parallel Kit Installation and operating instructions GB Z01 17.31 Table of Contents About this Manual... 2 Purpose... 2 Scope... 2 Keywords
More information- Wiring Brochure Zone Manager 336
- Wiring Brochure W 336 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure Wiring
More informationDifferential Pressure Sensors
1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output
More information1100 Series Piston Type Differential Pressure Gauges
1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.
More informationInstallation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................
More informationDT304. Digital Temperature Logger INSTRUCTION MANUAL
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DT304 INSTRUCTION MANUAL Digital Temperature Logger TABLE OF CONTENTS Introduction..........................................1
More informationIssue 2.0 December EPAS Midi User Manual EPAS35
Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationQuick Start Guide TK3/TK4 Thermal System Assembly and Fan Shroud Assembly
Quick Start Guide TK3/TK4 Thermal System Assembly and Fan Shroud Assembly This Quick Start Manual is effective for Consumer installations of the part numbers listed in Table 1 and Table 2. OEM installers
More informationβeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER
βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER USER MANUAL βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER (OPTIONAL) CHARACTERISTICS LCD display: all systems parameters
More informationOperating instructions
Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future
More informationOPERATING INSTRUCTIONS PLEASE READ CAREFULLY
OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS
More informationINDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice
INDUCTIVE CONDUCTIVITY SENSOR Instruction Manual Bürkert 00 Subject to technical change without notice INTRODUCTION Table of Contents. INTRODUCTION.... Symbols used.... General safety instructions....
More informationSolenoid Valve DF-SB-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY OPEN Solenoid Valve DF-SB-series The DF-DB is a semi-direct operated 2/2-way solenoid valve. The valve is normally open. The solenoid valves have an orifice of 16
More informationEPAS Desktop Pro Software User Manual
Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1
More informationALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features
Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when
More informationSmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE
BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF
More informationFLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER
FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when
More informationMILWAUKEE ELECTRIC TOOL CORPORATION TEST & MEASUREMENT PRODUCT. REPAIR SERVICE INSTRUCTIONS CALIBRATION Milliamp Clamp Meter
MILWAUKEE ELECTRIC TOOL CORPORATION TEST & MEASUREMENT PRODUCT REPAIR SERVICE INSTRUCTIONS CALIBRATION 2231-20 4-20 Milliamp Clamp Meter Environmental Condition Perform all calibration at an ambient temperature
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationINSTRUCTION MANUAL Oil level with pointer indicator
INSTRUCTION MANUAL Oil level with pointer indicator 5COL868200 REV.B I II CONTENTS 1. SAFETY... 1 1.1 Safety instructions... 1 1.2 Specified applications... 1 1.3 Safety notes on the equipment operation...
More information4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit
4.Failure phenomenon Phenomenon Mirage comes out from indoor unit Noise Sometimes, the room is smelly when heating, there is no wind at the beginning of starting unit Causing explanation When the cold
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationPiko Head Unit Piko 3 Piko X Piko U3
www.lupine.de Piko Head Unit Piko 3 Piko X Piko U3 OWNERS MANUAL Piko 1 Read this manual before using Mounting 2 General: The light and charger are ready for use when delivered. All you have to do is charge
More informationDocumentation. RM-BV4 Micro DP. Filter control
Documentation RM-BV4 Micro DP Filter control Contents 1 Safety instructions... 3 2 Device description... 3 3 Installation... 4 4 Installation... 5 4.1 Connection of the differential pressure measuring
More informationSliding doors / fire doors
Sliding doors / fire doors Installation Instructions for SCDmini TSm01.3 Please note that this documents relates to software for sliding doors and requires that program no. 20 is selected. If using UPS
More informationT Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1
T Series (N6052T) Solar Battery Hybrid System Installation Manual Version 1.1 Content 1. Safety... 1 1.1 How to Use This Manual... 1 1.2 Safety Rules... 1 1.3 Warning Notices Affixed to the Device... 2
More informationKelly KDHA High Voltage Series/PM Motor Controller User s Manual
Kelly KDHA High Voltage Series/PM Motor Controller User s Manual KDH07500A KDH07501A KDH07700A KDH07701A KDH09400A KDH09401A KDH09500A KDH09501A KDH12400A KDH12401A KDH12500A KDH12501A KDH14300A KDH14301A
More informationSolenoid Valve ST-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-SA-series The ST-SA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. The body material can be brass or stainless
More informationWARRANTY...1 NOTICE INTRODUCTION USE...8
Contents WARRANTY...1 NOTICE...2 1 INTRODUCTION...3 1.1 ABOUT...3 1.2 UNPACKING...3 1.3 INCLUDED ITEMS...4 1.4 COMPONENTS...4 2 USE...8 2.1 POWER ON...8 2.2 SETTINGS...9 2.2.1 Setup Wizard...9 2.2.2 Set
More informationSG-B1 SERIES / SG-A1 SERIES
643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &
More informationLevel Measuring Sensor for Diesel Fuel Tanks
Installation and Operating Manual Level Measuring Sensor for Diesel Fuel Tanks Executions with switchable output voltage signal: 0-2.3 V and industrial standard signal 0-10 V: Tank Sensor Diesel 010-250
More informationPSU EN54-4 Power Supplies
PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in
More informationMD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version
MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty
More informationHGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic
HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...
More informationTTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)
First, Sign and Date Bln 2009-03-9 Updated, Sign and Date Bln 200-04-29 (0) User Manual TTT802 Gearshift Controller Firmware for R--N-2- TTT802 Gearshift Controller, Part # 2-620-9-RN-S (Standard), -P
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >
More informationModel 124 Filter Minder & Model 124
Installation & Maintenance Instructions Model 124 Filter Minder & Model 124 Indicating Differential Pressure Switch / Transmitter Reading Office Cutbush Park, Danehill, Lower Earley, Reading, Berkshire.
More informationCONTENT 1 PICTURE GENERAL... 3
IP67 CONTENT 1 PICTURE... 3 1.1 GENERAL... 3 2 DIMENSIONS... 4 2.1 SYMBOLS... 5 2.2 PROTECTION FROM ELECTRIC SHOCK... 6 2.3 PROTECTIONS FROM FIRE AND BURNS... 6 2.4 PROTECTION FROM INJURY... 7 2.5 DISPOSING
More informationSERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016
SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or
More informationF-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide
F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com
More informationFlying Electron Inc. Bipolar Stepper Motor Driver Datasheet
Bipolar Stepper Motor Driver Datasheet Part Number: FE_STEPPER_BP rev. d Notice: To the best of our knowledge the information contained in this datasheet is accurate and is represented in good faith, however,
More informationKelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual
Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual HPM72601 HPM72801 HPM12401 HPM12601 HPM12801 HPM14301 HPM14501 HPM14701 Rev.3.4 Dec. 2016 Contents Chapter1 Introduction...
More informationFlowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual
Flowmeter Ultrasonic Flow Metering / Dosing Device Operating Manual Read the user's manual carefully before starting to use the unit or software. Producer reserves the right to implement changes without
More informationOpenEVSE - 40A Charging Station
OpenEVSE - 40A Charging Station P50 Advanced P50 Standard http://www.openevse.com Read and save these instructions prior to installing and operating your Charging Station. Retain this installation guide
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationILED Dorado. User Manual
10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...
More informationMAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important
More informationCVR-625. Compact Vibrating Rod Instruction Manual
CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS
More informationHGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...
CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...6 4.1. DISPLAY PANEL...6 4.2. LCD ICON INSTRUCTION...7 4.3. DISPLAY INSTRUCTIONS...7 4.4. DISPLAY DESCRIPTION...8
More informationInstruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1
Instruction Manual ThinkTop D30 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN3 2014-12 Original manual Table of contents The information herein is correct at the
More informationUSERS MANUAL MCD REMOTE OPERATOR
USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3
More informationMAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -
MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting
More informationMulti-Mover Charger for model L25
Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS
More informationSmall Full Bridge Permanent Magnet Motor DC Controller User Manual
Small Full Bridge Permanent Magnet Motor DC Controller User Manual SPM24051X SPM24101X SPM24121X SPM48051X SPM48101X SPM48121X SPM72051X SPM72101X SPM72121X SPM48151E SPM48181E SPM48221E SPM72151E SPM72181E
More information51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
51 & 52 Series II Thermometer Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Users Manual English September 1999 Rev.2, 11/10 1999-2010 Fluke Corporation,
More informationSource Capture Air Purification System
Source Capture Air Purification System HA-SCP-G3 Owner s Manual Table of Contents HealthyAir HA-IFM-1111 Filter 1 Important Safety Instructions 2 Technical Specifications 3 Packaging Reference 4 Packing