Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm)
|
|
- Sheryl McLaughlin
- 5 years ago
- Views:
Transcription
1 Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm) GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode 8mmx1/2 Angle Pattern TRV mmx1/2 Angle Pattern TRV mmx1/2 Angle Pattern TRV TRV DIMENSIONS (mm) Code Description A B C MMX1/2 CP TERRIER II TRV MMX1/2 CP TERRIER II TRV MMX1/2 CP TERRIER II TRV PRESSURE & TEMPERATURE TRV 8MMX1/2 CP TERRIER II TRV MATERIAL SPECIFICATIONS Minimum Operating Pressure (bar) No Minimum Operating Pressure Maximum Cold Working Pressure (bar) 10.0 bar at temperatures up to 120oC Maximum Hot Working Pressure (bar) Not Suitable for Maximum Hot Working Pressure Number Component Material 1 Body Forged Brass Chrome Plated 2 Head Brass Bar 3 Gland Brass Bar 4 Flow Spindle Stainless Steel 5 Capnut Forged Brass Chrome Plated 6 Cone Brass Bar 7 Adaptor Brass Bar Chrome Plated 8 Thermal Head Cover/Body ABS 9 Thermal Head Element/Housing Noryl SPARES
2 1 Angle Pattern TRV / 8mmx1/2 TH1 THERMAL HEAD - DISCONTINUED /01/ /04/2009 Angle Pattern TRV / 8mmx1/2 TH2 THERMAL HEAD /06/1998 current Angle Pattern TRV / 10mmx1/2 TH2 THERMAL HEAD /06/1998 current Angle Pattern TRV / 10mmx1/2 TH1 THERMAL HEAD - DISCONTINUED /01/ /04/2009 Angle Pattern TRV / 15mmx1/2 TH1 THERMAL HEAD - DISCONTINUED /01/ /04/2009 Angle Pattern TRV / 15mmx1/2 TH2 THERMAL HEAD /06/1998 current 2 Angle Pattern TRV / 8mmx1/2 HK68 COMPLETE CARTRIDGE 1/ /06/1998 current Angle Pattern TRV / 10mmx1/2 HK68 COMPLETE CARTRIDGE 1/ /06/1998 current Angle Pattern TRV / 15mmx1/2 HK68 COMPLETE CARTRIDGE 1/ /06/1998 current Angle Pattern TRV / 8mmx1/2 DC4 DUST CAP /01/ /05/1998 Angle Pattern TRV / 8mmx1/2 DC4 DUST CAP /06/1998 current Angle Pattern TRV / 10mmx1/2 DC4 DUST CAP /01/ /05/1998 Angle Pattern TRV / 10mmx1/2 DC4 DUST CAP /06/1998 current Angle Pattern TRV / 15mmx1/2 DC4 DUST CAP /06/1998 current Angle Pattern TRV / 15mmx1/2 DC4 DUST CAP /01/ /05/1998 Angle Pattern TRV / 8mmx1/2 TP1CP CHROME TAIL PIPE /01/ /05/1998 Angle Pattern TRV / 8mmx1/2 TP1CP CHROME TAIL PIPE /06/1998 current Angle Pattern TRV / 10mmx1/2 TP1CP CHROME TAIL PIPE /06/1998 current Angle Pattern TRV / 10mmx1/2 TP1CP CHROME TAIL PIPE /01/ /05/1998 Angle Pattern TRV / 15mmx1/2 TP1CP CHROME TAIL PIPE /01/ /05/1998 Angle Pattern TRV / 15mmx1/2 TP1CP CHROME TAIL PIPE /06/1998 current Angle Pattern TRV / 8mmx1/2 LP7 LOCKING PIN (PACK OF 2) /01/1900 current Angle Pattern TRV / 10mmx1/2 LP7 LOCKING PIN (PACK OF 2) /01/1900 current Angle Pattern TRV / 15mmx1/2 LP7 LOCKING PIN (PACK OF 2) /01/1900 current CARE & MAINTENANCE Care The TRV can be easily cleaned with a soft damp cloth wiping over the handle (plastic) and valve body. Maintenance No maintenance is required for this product. When removing the TRV head for decorating or replacement purposes, turning the head setting to 5, this enables an easier removal. A manual shut off cap is provided with the product to protect the valve whilst any surrounding maintenance work is undertaken. For any further help or replacement parts please contact the Service Support Team on: REGULATIONS Regulations Terrier thermostatic radiator valves are approved to EN 215. For valves with compression connections, the connections are approved to BS EN1254-2; threaded connections comply with BS 21 or BS They are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions Maximum System Water Temperature (at 5bar) 120 C Operating pressure (at 65 C) 10 bar Under no circumstances must they be used in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer's instructions. Terrier heating controls are manufactured to a strict quality assurance system in accordance with ISO 9000: 2001.
3 GUARANTEE Thermostatic and Manual Radiator Valves Pegler Yorkshire Customcare 5 Year Guarantee - Terms & Conditions Products are subject to a 5 year guarantee that is between Pegler Yorkshire and the final purchaser of the product. The guarantee is subject to proof of purchase being supplied. This guarantee does not affect any statutory rights the consumer may have in law. The guarantee covers manufacturing or material defects and is not applicable where the product is fitted contrary to conditions of use in our literature. The guarantee is subject to the following limitations: 1. The valves are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. 2. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions (Maximum) System Water Temperature (at 5bar) : 120 C Operating pressure (at 65 oc) :10 bar 3. Under no circumstances must they be used to in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer s instructions. 4. Damage caused by abusive behaviour and accidental damage to the product are not covered by this guarantee The extent of Pegler Yorkshire liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages. APPROVALS Keymark License EN215
4
5 terrier trv 8/9/04 2:25 pm Page 1 4. Range Limiting or Fixed Set Temperature The terrier TRV has the facility for fixing the thermal head at a set temperature or to limit the range of operation. This is achieved by using the two pegs provided with the product. To obtain a fixed set point, locate a peg in the slot either side of the selected setting and push home. To set a limited range for temperature control, first locate a peg in the slot to the right of the viewing window for the lowest temperature setting required. Adjust the valve head to display the maximum temperature desired. Locate a peg in the slot to the left side of the viewing window. Push both pegs home. The head will now be adjustable between the selected range of temperature. 5. Frost Protection If you plan to be away from home for any length of time the TRV can be turned to the frost protection setting. If the temperature falls below 7 C the valve will automatically open giving protection against freezing. (Provided that the boiler remains in operation via a frost stat.) 6. Removal of Radiator TWO WAY THERMOSTATIC RADIATOR VALVE TECHNICAL DATA Temperature range 7 C - 28 C Maximum Test Pressure 20bar Maximum Static Pressure 10bar at 120 C Maximum Differential Pressure 0.6bar Maximum Water Flow Temperature 120 C The 0 Setting on the TRV is a positive Off position. This will enable a radiator to be removed for maintenance purposes. To avoid accidental operating of the valve or damage whilst decorating the manual shut off cap may be used for added security instead of the TRV head. In this case, remove the TRV sensor head by unscrewing the securing ring and replacing with the manual cap BEFORE removing the radiator. Pegler Limited, St. Catherines Avenue, Doncaster DN4 8DF. Telephone: Fax: TWO WAY THERMOSTATIC RADIATOR VALVE Installation and User Guide SENSOR HEAD MANUAL SHUT OFF CAP 1/2 BSP TAIL VALVE BODY VALVE BODY STRAIGHT
6 terrier trv 8/9/04 2:25 pm Page 2 INSTALLATION Directions for use: Angle TRV The universal terrier TRV is designed to operate with water flow in either direction. The 15mm size may be fitted in either the horizontal OR vertical position. The most effective position is to have the head in a horizontal position where the greatest efficiency will be obtained. Straight TRV Straight bodied valves should not be used in the top connection of a radiator as heat from the radiator will affect the sensor. Correct installations Correct installation and maximum performance will be achieved if: The thermostatic head is not concealed behind furniture, curtains or drapes, hidden under shelves, panelling or in a recess where air pockets can occur. The thermostatic head is not exposed to direct sunlight or draughts. Straight TRV x Fitting 1. Thoroughly clean any pipe work to be connected to the valve. 2. Drain down existing system, connecting a hosepipe to the lowest drain off point available. 3. Screw 1/2 BSP tail into radiator tapping, using suitable jointing material e.g. PTFE tape. 4. Connect valve body to tail and tighten nut. 5. Cut and fit copper tube to valve body - tightening nut and cone. 6. Remove manual shut off cap and store safely. 7. Turn Sensor head to indicate 5 in setting window. 8. Position sensor head so that setting window can be viewed and hand tighten securing ring to valve body. 9. Set sensor head to required temperature setting. 10. When fitting a lock shield valve, this must be set to control the water flow through the radiator to the correct level. PLEASE NOTE: To avoid the problem of hydronic (water flow) noise it is recommended that the differential pressure does not exceed 0.2 bar. It is strongly recommeded that a differential pressure valve should be fitted to any system with TRV s (Pegler order code for differential pressure valve /22mm) will be suitable for most domestic installations. Larger sizes are available if required. Angle TRV USER INSTRUCTIONS 1. Operating Description The influence of uncontrolled heat gains from cooking, lighting and sunshine etc., can lead to wasteful overheating. The terrier TRV is designed to react to temperature fluctuations and allow you to control individual room temperature. The sensor head contains a powerful wax-filled sensor which senses temperature changes. These variations cause expansion and contraction of the thermal element which is transmitted to a valve seat which regulates the water flow to the radiator 2. Setting the TRV Initially set the TRV to the required room temperature from the table below e.g. Position 3/ 20 C. The TRV should be left for at least 1 hour to allow the temperature to stabilise. If a higher or lower room temperature is required simply adjust the setting accordingly and repeat the process. 3. Temperature Settings The TRV settings are factory calibrated as indicated in the table below Shut Off 7 C C C C C C Note: These temperatures may vary slightly, depending upon the nature of the installation
Lockshield Radiator Valve Angle Pattern for copper or iron
Lockshield Radiator Valve Angle Pattern for copper or iron 97 CPLS Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode 15mm / 1/2x1/2 97 CPLS 1 10 680008 5013866017964 18mm / 1/2 x 1/2 97 CPLS 0 0 680012
More informationWheelhandle Radiator Valve Angle Pattern for copper or iron
Wheelhandle Radiator Valve Angle Pattern for copper or iron 97 WH Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT Discontinued Date Discontinued 15mm / 1/2x1/2 22mm / 3/4x3/4 15mm
More informationFloatvalve Nylon Seat BS 1212 Part one high pressure
Floatvalve Nylon Seat BS 1212 Part one high pressure 857N Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT 1/2 857N 20 0 514007 5013866016578 10.67 3/4 857N 5 0 514008 5013866016585
More information12415_Pegler_Terrier_8pp_v8 16/1/06 3:06 pm Page 2. Turn on the style... Decorative Radiator Valves
12415_Pegler_Terrier_8pp_v8 16/1/06 3:06 pm Page 2 Turn on the style... Decorative Radiator Valves 12415_Pegler_Terrier_8pp_v8 16/1/06 2:49 pm Page 3 It pays to choose Pegler... Cutting corners on plumbing
More informationEqual tee push-fit on all ends
Equal tee push-fit on all ends TT24/TT130 Tee Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT test 10mm TT24/TT130 10 200 75555 5022050113122 3.74 12mm TT24/TT130 10 150 75709 5022050183170
More informationSOLDER RING FITTINGS GENERAL RANGE
Product Guide Size Pk Pk Code SOLDER RING FITTINGS GENERAL RANGE Fittings are manufactured from and alloy Available in sizes from 8-4mm Fittings are designed for jointing tubes to BS EN 7 in hot and cold
More informationW Range Solder Ring Fittings
//7 TECH DATA SHEET 49 W Range Solder Ring Fittings Size Pk Pk Code MERCIA W RANGE SOLDER RING FITTINGS GENERAL RANGE Fittings are manufactured from and alloy Available in sizes from 8-4mm Fittings are
More informationTHERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions
THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions Please retain for future reference DUAL INLINE CONCEALED VALVE SV2204 / SV4404 / SV5504 / SV6604 SV7704 / SV8804 / SV9904
More information1901 Thermostatic Shower Mixer
1901 Thermostatic Shower Mixer (Universal Valve with Adjustable Riser, Surface Mounted Valve with Rigid Riser or Recessed Valve with Fixed Head) Fitting Instructions & Contents List Before starting any
More informationSize Pattern No. Pack 1 Qty Code Barcode na Basin Pillar Tap CP Pair
or latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk Healthcare + asin Pillar Tap asin Pillar Tap GNRL INORMTION Pattern No. key :P : hrome Plated
More informationRUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES
RUSH WALL TOP ASSEMBLIES EXT D 1MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES CERAMIC DISC CARTRIDGE PHOENIX WARRANTY MATCH WITH... TECHNICAL SPECIFICATIONS CONSUMER
More informationSoft Touch Tap Range. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts
Soft Touch Tap Range Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Safety Note 03 3. Specification
More informationPRESSURE CONTROL VALVES SABS 198
PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge
More informationRUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH
RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME STYLISH PREMIUM CHROME FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY MATCH WITH... TECHNICAL SPECIFICATIONS CONSUMER INFORMATION 65
More informationVIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY
VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY MATCH WITH... TECHNICAL SPECIFICATIONS CONSUMER INFORMATION RANGE:
More informationGLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...
GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME STYLISH PREMIUM CHROME FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY MATCH WITH... TECHNICAL SPECIFICATIONS CONSUMER INFORMATION RANGE: GLOSS PRODUCT:
More informationPLEASE READ. Easy Installation
Instruction Booklet PLEASE READ - Please read these instructions carefully before starting installation and retain it for future reference. Please leave this instructions with the end user. - Remove all
More informationInstruction Booklet. P.O. Box Berkeley Rd UNANDERRA,NSW 2526 Australia Tel:
Instruction Booklet P.O. Box 14 237 Berkeley Rd UNANDERRA,NSW 226 Australia Tel: +61 2 4271 2444 info@blueaustralia.com.au Jamie.J Tapware & Accessories, a division of Architectural Designer Products BASIN
More informationANTI VANDAL TAPWARE. Installation Instructions CONCEALED SPINDLE (CS) SERIES SCHOOL PATTERN (VP) SERIES TRADITIONAL/INSTITUTIONAL (IN) SERIES
ANTI VANDAL TAPWARE Installation Instructions CONCEALED SPINDLE (CS) SERIES SCHOOL PATTERN (VP) SERIES TRADITIONAL/INSTITUTIONAL (IN) SERIES PLAZA (PZ) SERIES I00042_Nov 17 www.enware.com.au Enware Australia
More informationINSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler
INSTALLATION MANUAL 252418 Wolfen 122 Wall Bubbler 252465 Wolfen 90 Wall Bubbler 252419 Wolfen Hob Bubbler 252420 Wolfen Remote Button Bubbler Installation Details Warranty CONTENTS Intro 03 Technical
More informationPrism Floor Standing Bath Shower Mixer
Prism Floor Standing Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading showers and taps
More informationOMIKA. it s a personal experience. Installation Guide Wall Mounted Basin Mixer. This instruction booklet covers this model: OMI-109.
it s a personal experience OMIKA Installation Guide 09 This instruction booklet covers this model: OMI-09. Version, -8-7 Vado Wedmore Road, Cheddar, Somerset, England BS7 EB tel 09 766. fax 09 75 aftersales@vado.com
More informationTHERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions
THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions Please retain for future reference EXPOSED CONCENTRIC VALVE SV2201 / SV4401 / SV5501 / SV6601 SV7701 / SV8801 /
More informationPACIFICA Shower Cabin Installation Instructions
PACIFICA Shower Cabin Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation
More informationRISER PIPE, SHOWER ARM, ADJUSTABLE BRACKET & 2 WAY RISER DIVERTER ASSEMBLIES INSTALLATION GUIDE
RISER PIPE, SHOWER ARM, ADJUSTABLE BRACKET & 2 WAY RISER DIVERTER ASSEMBLIES INSTALLATION GUIDE DIMENSIONS Riser pipes for wall mounted bath shower mixers The pipes are Ø19mm and connections are made
More informationValencia Radiator Valve Range
Valencia Radiator Valve Range VTL00 VTL0 VHL0 VT00 VT Application PRODUCT DATA SHEET Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy.
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS CW-4533 (LB 1726) SHOWER SLIDING RAIL KIT FOR USE WTH CONICAL END HOSE
INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS CW-4533 (LB 1726) SHOWER SLIDING RAIL KIT FOR USE WTH CONICAL END HOSE Contents Dimensions 3 Warning Information 4 Instal ation Procedure 5 Parts List
More informationPEGLER YORKSHIRE TERRIER PRICE LIST CONTENTS
PEGLER YORKSHIRE TERRIER PRICE LIST CONTENTS Heating Solutions Domestic Radiator Valves 3-7 Commercial Radiator Valves 8-13 Decorative Radiator Valves 14-17 Heating Controls 18 Valves 19 Maintaining a
More informationDPLS2 MANUFACTURED FOR: MITSUBISHI ELECTRIC US, INC. Drain Pan Level Sensor/Control. for use with:
MANUFACTURED FOR: MITSUBISHI ELECTRIC US, INC. Drain Pan Level Sensor/Control DPLS2 for use with: M-Series MFZ, MS, MSY/Z, SEZ, SLZ, MSZ-FH and MVZ P-Series PCA, PEA, PEAD, PKA, and PVA CITY MULTI PCFY,
More informationGlastonbury Tap Range Installation Instructions and User Guide
Glastonbury Tap Range Installation Instructions and User Guide Models covered: TGRC00 / TGRG00 TGRC01 / TGRG01 TGRC02 / TGRG02 TGRC07 / TGRG07 Basin Taps Bath Taps Bath Shower Mixer Bath Filler Please
More informationPRICE LIST 1ST APRIL Pegler Yorkshire
PRICE LIST 1ST APRIL 2018 Pegler Yorkshire PEGLER YORKSHIRE TERRIER PRICE LIST CONTENTS Heating Solutions Domestic Radiator Valves 3-7 Commercial Radiator Valves 8-13 Decorative Radiator Valves 14-16 Valves
More informationROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727
ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No. 1-523 Trim Kit for Model No s: 1047, 1707, 1727 Congratulations on the purchase of this Newport Brass product, an excellent
More informationT100A,F,M Controllers
T100A,F,M Controllers THERMOSTATIC VALVE ACTUATORS INSTALLATION INSTRUCTIONS APPLICATION The T100 Controllers are used with V100 Valves to control radiators, convectors, baseboard heating units, or other
More informationBrass chrome plated ball valve with lever, full bore. XPress press end x Tectite push end for copper/carbon steel/stainless steel tube
Brass chrome plated ball valve with lever, full bore. XPress press end x Tectite push end for copper/carbon steel/stainless steel tube XT500 Ball valve Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode
More informationYour Guide to the Installation, Care and Maintenance of. BRITA/Francis Pegler: 3-Way Titanium and 3-Way Rosedale
Your Guide to the Installation, Care and Maintenance of BRITA/Francis Pegler: 3-Way Titanium and 3-Way Rosedale SYSTEM REQUIREMENTS: The BRITA inline filter is designed to improve the taste and appearance
More informationYour Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)
Your Guide to the Installation, Care and maintenance of PERFORMA Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027) Pegler Limited, St Catherine s Avenue, Doncaster DN4 8DF Telephone
More informationInstallation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions
Installation, Care and Maintenance Instructions Optiflush OP1 Battery and OP2 Mains Versions The Prestex Optiflush Congratulations on buying the Prestex Optiflush Urinal Flush Controller. The product utilises
More informationVRETA. Year Limited Warranty INCLUDED
VRETA 10 Year Limited Warranty INCLUDED Everyday life at home puts high demands on seating. VRETA seating series is tested to comply with our strict standards for quality and durability as well as with
More informationBATH FILLER & BATH / SHOWER MIXER Installation & aftercare instructions
GENERAL NOTES This mixer should be installed in accordance with water regulations. Approved check valves should be fitted where required. For further details please contact your local water authority.
More information88A-100 Series. Carbon Steel ANSI Class 150 Flanged Std. Port Ball Valve - 1-1/2 through 2 STANDARDS COMPLIANCE STANDARD FEATURES
Carbon Steel ANSI Class 150 Flanged Std. Port Ball Valve - 1-1/2 through 2 2. Retainer ASTM A108 Type 1215 3. Ball ASTM A108 Type 1215 Chrome Plated 9. Gland Plate 302 or 304 SS 10. Stem Nut 316 SS 11.
More informationMira Mode Shower and Bath Fittings
Mira Mode Shower and Bath Fittings Installation Guide Please leave these instructions with the user If you experience any difficulty with the installation or operation of your new shower, then please refer
More informationIssue 3. Description: ROBINHOOD TAP PULL-OUT SERIES Model Numbers: TPO1200. Model may vary slightly from image pictured
Issue 3 Description: ROBINHOOD TAP PULL-OUT SERIES 1 200 Model Numbers: TPO1200 Model may vary slightly from image pictured Overview Contents of packaging 1 x Robinhood Tap Pullout 1 x Installation kit
More informationFASHION SKIRTED TOILET FOR P & S TRAPS DUAL FLUSH OWNER S MANUAL ITM. / ART # QTA023
DUAL FLUSH FASHION SKIRTED TOILET FOR P & S TRAPS OWNER S MANUAL ITM. / ART. 161018 # QTA023 Table of Contents Important Information...2 Warranty One Year Limited Warranty...3 Warranty Claim Procedure...3
More information5579P. Watersmith Twin Outlet Diverter Shower Kit. Barcode: Warning! Read the instructions before using the appliance.
Watersmith Twin Outlet Diverter Shower Kit 5579P-Screwfix-IM-EN-V01 5579P Barcode: 5052931652556 Warning! Read the instructions before using the appliance. 5579P-Screwfix-IM-EN-V06.indd 1 5/16/16 5:58
More informationReversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)
Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35
More information2-DOOR LAUNDRY CABINET KIT
2-DOOR LAUNDRY CABINET KIT OWNER S MANUAL QL054 # 6725159 Table of Contents Table of Contents....2 Safety Information....2 Warranty....3 Warranty Claim Procedure....3 Pre-Installation....4 Tools/Materials
More informationInstallation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain
Installation Instructions JASMINE 80. Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain Congratulations on purchasing your American Standard faucet with the EverClean finish and Speed
More informationInstallation Instructions Melba Sink Mixer
Installation Instructions Melba Sink Mixer Models covered: MLB SNK WHT/ BLK Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them
More informationHANDS FREE FOOT & KNEE OPERATED TAPWARE
HANDS FREE FOOT & KNEE OPERATED TAPWARE Installation Instructions FOOT OPERATED KNEE OPERATED KNEE OPERATED TIME FLOW Self-closing Spring Action mechanism, installed on the floor and operated by pushing
More informationVANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT
VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL SHOWER FITTINGS IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product
More informationINSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet
INSTALLATION MANUAL 252460 Wolfen Foot Operated Pedal Valve 252957 Wolfen Foot Operated Kit with Outlet Installation Details Warranty CONTENTS Intro 03 Technical Information 04 Unit Components 06 Installation
More informationVANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT
VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL SHOWER FITTINGS IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product
More informationTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
BEAT SHOWERHEADS SINGLE SPRAY 1703.009, 1703.011 ADJUSTABLE 1703.010, 1703.012 Installation and User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 INTRODUCTION The Mira adjustable showerhead
More informationMIZU QUICK CHANGE DUAL FILTER SYSTEM
QUICK CHANGE DUAL FILTER SYSTEM page 1 of 5 130mm 290mm 70mm 380mm 100mm (filter unit depth) 180mm Dimensions are nominal measurements only. 1. 3/4 Multifunction valve 2. Filter isolating valve 3. 90 deg
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationMikrotherm F. Manual Radiator Valves With presetting
Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating
More information(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.
OPERATOR S MANUAL 12 VOLT LITHIUM-ION BATTERY CHARGER 140446001 (R86049) Your charger has been engineered and manufactured to our high standards for dependability, ease of operation, and operator safety.
More informationX-tra Collection for designer radiators and bathroom towel rails
and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes
More informationDual Flow Manifold Systems Instruction Manual
3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.
More informationX-tra Collection for designer radiators and bathroom towel rails
and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes
More informationOperating & Maintenance Manual Tap Box & Tap Guard Arrow Valves Arrow Valves Ltd
Arrow Valves Ltd Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Installation Instructions / Operating & Maintenance Manual Tap Box - Secure Outside Hose Tap Models - HUTB, HUTBS & HUTBT Tap
More informationEngine Cooling. Cooling System Component Layout. https://myvpn.dealerconnection.com/extdealerlrprod/xml/parsexml.jsp,danainfo=gtr.fran...
Page 1 of 5 Published : Apr 28, 2004 Engine Cooling Cooling System Component Layout Item Part Number Description 1 - Heater hose, inlet and outlet 2 - Heater hose, inlet and outlet for vehicles with rear
More informationCarbon Steel ANSI Class 150 Flanged Full Port Ball Valve -
Description (1/2 & 3/4 Valves) Material 2. Retainer ASTM A108 Type 1215 3. Ball ASTM A108 Type 1215 8. Stem Nut 300 Series Stainless Steel 9. Lever 300 Series Stainless Steel w/vinyl Grip 10. Stem Bearing
More informationINSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap
INSTALLATION MANUAL 252432 Wolfen Hand Held Trigger Spray Assembly With Stop Tap 252444 Wolfen Pre Rinse Slophopper Assembly Without Tap 252431 Wolfen Pre Rinse Trigger Spray Installation Details Warranty
More informationPh: (07) Fax: (07) Pump Manual
sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY
More informationScale Feeder Manifold Water Filtration System Instruction Manual
3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.
More informationInstallation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743
NOTE: Carefully read instructions entirely before assembling/installing this product. Parts Included Qty Parts Included Qty Tire Carrier 1 8 x 70mm Hex Bolt 4 Brake Light Bracket 1 8mm Flat Washer 4 Tire
More information1/7 HANDLE TRIM INSTALLATION
Rev 06/2016 Installation Instruction AVA COLLECTIONS Roman Tub Filler with Hand Shower Please read the instructions completely before beginning the installation. Ava Collection Model Number: 9955CU-TM
More informationRada Outlook 150, 190 & 225mm Sensor Spout. For wall panel installation PRODUCT MANUAL
Rada Outlook 150, 190 & 225mm Sensor Spout For wall panel installation PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance
More informationSIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions
SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationHigh capacity valve body, type RA-G
Application The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). The
More informationBallofix isolating service valves
Ballofix isolating service valves Ballofix isolating service valves Pegler Ballofix isolating service valves for potable water, From its introduction more than fifty years ago the Pegler Ballofix ball
More informationSail Extension Tap Range
Sail Extension Tap Range Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading showers and taps expert. We
More informationTECHNICAL DATA SPRINKLER ESCUTCHEONS
Page 1 of 8 1. DESCRIPTION Viking sprinkler escutcheons are ornamental plates used with ½ NPT (15 mm BSP)*, and ¾ NPT (20 mm BSP)* pendent sprinklers. The escutcheons are installed between the sprinklers
More informationInstallation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty
TM Limited Lifetime Faucet Warranty fluid warrants its faucets to be free from defects in material and workmanship for as long as the original consumer purchaser owns his or her home.* This warranty applies
More informationExcel Wall and Deck Mounted Bath Shower Mixers Installation and User Guide
005 Excel Wall and Deck Mounted Bath Shower Mixers Installation and User Guide 1559.006 1559.007 MODEL NUMBERS Important :- Please quote the above model number(s) when ordering spares. IMPORTANT! Installer:
More information1004D2/1005E API Bottom Loading Coupler. 1005E Small handles used throughout Europe 1004D
PART #H32183PA February 2009 1004D2/1005E API Bottom Loading Coupler The 1004D2 is the standard in drip-less bottom loading couplers and a proven performer at major oil terminals worldwide. The 1004D2
More informationInstallation Instructions Blitz Tap Range
Installation Instructions Blitz Tap Range Models covered: BTZ 1/2 C, BTZ 3/4 C, BTZ BAS C, BTZ SMBAS C, BTZ 1HBF C, BTZ BSM C, BTZ BF C, Please keep this booklet for future reference. Installer, when you
More information28W WORK LAMP Model: CTL28 Part No:
28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609 INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read
More informationInstallation Instructions Cobalt Tap Range
Installation Instructions Cobalt Tap Range Models covered: COB 1/2 C, COB 3/4 C, COB BAS C, COB BF C, COB BSM C, COB SMBAS C, COB 1HBF C Please keep this booklet for future reference. Installer, when you
More informationINSTALLATION, OPERATION & SERVICE INSTRUCTIONS
Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Symmons valves and shower heads comply to all known standards, codes and
More informationInstallation & aftercare instructions
INSTRUCTIONS Whilst this item has a high quality durable finish, it should nevertheless be treated with care. Surfaces should be cleaned using only a soft damp cloth and clean water & dried using a soft
More information2-DOOR LAUNDRY CABINET KIT
2-DOOR LAUNDRY CABINET KIT OWNER S MANUAL QL055 # 6725161 Table of Contents Table of Contents...2 Safety Information...2 Warranty...3 Warranty Claim Procedure...3 Pre-Installation...4 Tools/Materials Required...4
More informationFOR HEATING & PLUMBING SYSTEMS
Quality Plastics Ltd. Pushfit Option Compression Option MANIFOLD SYSTEM ADVANTAGES: Central Control. Eliminates variations in pressure and flow. Individual pipes to each outlet allowing separate shut-off
More informationVR2-CC VR2-RS VR2-ES PRODUCT MANUAL
VR2-CC VR2-RS VR2-ES PRODUCT MANUAL IMPORTANT INSTALLER: THIS MANUAL IS THE PROPERTY OF THE CUSTOMER AND MUST BE RETAINED WITH THE PRODUCT FOR MAINTENANCE AND OPERATIONAL PURPOSES. 1 CONTENTS Introduction...3
More informationModule 7: Cooling System Components
 Â  Basic Cooling System Components Radiators Common Types of Radiators Coolant Hoses Water Pumps Centrifugal Force Types of Drives for Water Pumps Types of Drive Belts Basic Cooling System Components
More informationEveryday life at home puts high demands on a sofa. Our sofas are rigorously tested to comply with our strict standards for quality and durability as
Sofas and Armchairs Everyday life at home puts high demands on a sofa. Our sofas are rigorously tested to comply with our strict standards for quality and durability as well as with the highest standards
More informationInstallation Instructions
Installation Instructions Thermostatic Valve and Trim Model No. RH-5944 1 REV.A Restoration Hardware Product Size Specification Diagram General Characteristics In case of instantaneous heaters, hot water
More informationAssembly Instructions
Assembly Instructions Aluminum Padded Sling Chaise Lounge Questions, problems, or missing parts? Before returning to the store, call Customer Service. -866-988-3300 8 a.m. -5 p.m., PST Monday - Friday
More informationInstallation Instructions / Warranty
Installation Instructions / Warranty Axor Citterio 39144XX1 Axor Citterio 39148XX1 Axor Citterio Wall Mount Lav Mixer with Cross Handles 39144XX1 Axor Citterio Wall Mount Lav Mixer with Lever Handles 39148XX1
More informationPlease refer to our catalogue for details of the full product range
Thermostatic Radiator Valve Bodies Series V6 - Double Regulating Function ngle Pattern 118 37 63 118 37 64 11.10 11.10 EPDM disk & seals (see note below) F x MU ends Thermostat connection thread M30 x
More informationEbony Extension Tap Range
Ebony Extension Tap Range Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading showers and taps expert. We
More informationSOVEREIGN STYLE B LST RADIATOR INSTALLATION INSTRUCTIONS (COPPER ALUMIMIUM HEAT EMITTER)
29TH APRIL 2008 - ISSUE 5 SOVEREIGN STYLE B LST RADIATOR INSTALLATION INSTRUCTIONS (COPPER ALUMIMIUM HEAT EMITTER) AUTRON PRODUCTS LTD 17 SECOND AVENUE BLUEBRIDGE INDUSTRIAL ESTATE HALSTEAD ESSE C09 2SU
More informationSUPERPLUS WATER FILTRATION SYSTEM
SUPERPLUS WATER FILTRATION SYSTEM For Model #: SP20-1 INSTRUCTIONS/ASSEMBLY USE AND CARE MANUAL (Important: Read this manual thoroughly before install) TABLE OF CONTENTS 2 3 4 6 8 9 10 11 12 General Notes
More informationInstallation Instructions
Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. P r o d u c t s Luxury Faucets and Accessories Savina Product Numbers
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationELECTRIC WATER PUMP (EWP ) KIT INSTALLATION INSTRUCTIONS
77 Taras Avenue P.O. Box 363 Altona North Vic 3025 Australia Phone: +61(0)3 9369 1234 Fax: +61(0)3 9369 3456 info@daviescraig.com.au ELECTRIC WATER PUMP (EWP ) KIT INSTALLATION INSTRUCTIONS EWP80, EWP115,
More informationACE. DOUBLE DOOR QUADRANT Installation and User Guide. These instructions must be left with the user W2-E
ACE DOUBLE DOOR QUADRANT Installation and User Guide These instructions must be left with the user 1 CONTENTS Introduction...2 General...2 Guarantee...3 Recommended Usage...3 Safety Precautions...3 General...3
More informationZonePlus Z322 zone valve Installation and commissioning instructions
ZonePlus Z322 zone valve Installation and commissioning instructions The Z322 mid-position valve has been designed to control the water circulation in fully pumped systems, which employ a single pump for
More information