Model. Port size (Nominal size B) Weight (kg) 1/ 8, 1/ 4, 3/ 8 1/ 4, 3/ 8, 1/ 2 3/ 8, 1/ 2, 3/ 4 1/ 2, 3/ 4, 1 3/ 4, 1 1, 11/ 2 11/ 2, 2

Size: px
Start display at page:

Download "Model. Port size (Nominal size B) Weight (kg) 1/ 8, 1/ 4, 3/ 8 1/ 4, 3/ 8, 1/ 2 3/ 8, 1/ 2, 3/ 4 1/ 2, 3/ 4, 1 3/ 4, 1 1, 11/ 2 11/ 2, 2"

Transcription

1 Odor Removal Filter Series AMF Series AMF Odor Removal Filter efficiently removes odour in compressed air with an activated carbon element. The unit is designed for use in food processing, pharmaceutical, brewing and breathing systems where odours must be removed. Model Model AMF Rated flow (l/min (ANR)) (1) 200 Port size (Nominal size ) Weight (kg) AMF20 00 AMF30 00 AMF AMF0 300 AMF AMF /, 1/ 4, 3/ 1/ 4, 3/, 1/ 2 3/, 1/ 2, 3/ 4 1/ 2, 3/ 4, 1 3/ 4, 1 1, 11/ 2 11/ 2, Note 1) Max. flow capacity at a pressure of 0.7MPa. It varies depending on operating pressure.refer to ''Flow Characteristics" p and figure of "Max. air flow" p Removes odour and gas ingredients in compressed air. Activated carbon element with large filtration area (1420m 2 /g) Easy replacement of element Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature Filtration rating Oil mist removal rate Compressed Air 1.0MPa 0.0MPa 1.MPa to 60 C 0.01µm(9% particle size collection) Less than 3. particles 0.3 µm or larger per liter of air (0 particles or less per cubic foot) (Series "AME" should be installed at upstream.) Accessories Applicable model racket assembly With cap bolt, spring washer (Options) AMF AMF20 AMF30 AMF40 AMF0 AMF60 AMF M1 M2 M3 M4 M M6 M7 Refer to ''Precautions" on p Symbol AMF 4.-27

2 Odor Removal Filter Series AMF How to Order AMF to AMF AMF R ody size Port size (Dimension ) Thread 03 3 Rc(PT) F G(PF) N NPT Accessories (Optional) None With bracket Option R IN, OUT reversal Note) Refer to p regarding How to Order of case assembly. How to Select Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6MPa Max.air flow capacity: m 3 /min(anr) q Select the point of contact A of inlet pressure and max.air flow capacity in the graph. w Select the type whose max.air flow capacity is over that point; AMF60. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point. With a model that has the maximum flow rate line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. Max. Air Flow HA ID AMG AFF AM FQ1 Related products 4.-2

3 Series AMF Flow Characteristics/Refer to How to Select p regarding model selection. Note) Compressed air over max. flow line in the table below may not meet the specifications of the product. It may cause damage to the element. Element initial condition AMF 1/ AMF0 3/4 AMF20 1/4 AMF60 1 AMF30 3/ AMF 1 1 /2 AMF40 1/

4 Odor Removal Filter Series AMF Construction AMF to AMF60 Component Parts No. Description q ody w Housing e Sight glass Replacement Parts No. Description Material r Element assembly With gasket and O ring Glass fiber NR Material Note Aluminum die cast Aluminum die cast Chrome treatment Epoxy coating on inner surface Tempered glass AMF is aluminum casting. AMF AMF-EL AMF20 AMF-EL20 AMF30 AMF-EL30 Note) Sight glass is indicated in the figure above for easy understanding of parts, however mounting position is different. Refer to dimensions p and for details. Part No. AMF40 AMF-EL40 AMF0 AMF-EL0 AMF60 AMF-EL60 AMF AMF-EL HA ID AMG AFF AM FQ1 Related products 4.-30

5 Series AMF Dimensions: AMF to AMF30 Model AMF AMF20 AMF30 Port size A (Nominal size ) 1 /, 1 / 4, 3 / / 4, 3 / 12 1 / /, 1 / / C D 63 E F 63 G H I 6 J Dimensions with mounting bracket K L M N O 4 P Q R 4. S

6 Odor Removal Filter Series AMF Dimensions: AMF40 to AMF Model AMF40 AMF0 AMF60 AMF Port size Dimensions with mounting bracket A C D E F G H (Nominal size ) I J K L M N O P Q R S 1 2, , , , HA ID AMG AFF AM FQ1 Related products 4.-32

7 Series AMF Precautions e sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalogue, and refer to p.4.0- to for more detailed precautions of every series. Caution on Design Caution q Design the layout so that the mist separator is installed in an area that is less susceptible to pulsations. The element could be damaged if the difference in internal and external pressures exceeds 0.1MPa. w Do not use it with anything other than dry air (such as air containing moisture). e Make sure to install a micromist separator (AMD Series), a micromist separator with a prefilter (AMH Series) or a supermist separator (AME series), on the primary side. r The bracket that is provided with the product is for supporting the product itself. Thus, it cannot support the piping or other items that are connected. If these items need to be supported, provide an additional support. Maintenance Caution q It is not possible to indicate a definite replacement interval for the element because it varies with the odour concentration of the compressed air. Verify the effective deodourization time. Thereafter, replace the element on a regular basis. w To use the odour remover filter for the first time, verify the effective deodourization time according to the procedure indicated below. 1) Record the date on which the odour remover filter is put into operation. 2) Calculate the total length of time that has elapsed from the time it was put into operation until it has started to emit an oil odour. 3) Use the length of time calculated in step 2) as an approximate effective deodourization time. If changes are made to the operating conditions, the effective deodourisation time must be checked again. e Even if its deodourisation performance has not decreased, the replacement interval for the element is when the pressure drop reaches 0.1MPa or after 2 years of operation, whichever comes first. r When the element has reached its replacement interval, replace it immediately with a new element. Replace the O ring, the gasket, and the element with new parts. Mounting Caution q Verify the direction of the flow of the compressed air and the " " mark that indicates the inlet of the product before connecting. It cannot be used if connected in the opposite direction. w Make sure to install this product on horizontal piping

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid

Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid Water Separator RoHS Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element

More information

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments

More information

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients

More information

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2 Mist Separator Series ohs Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (For details,

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter Series Series / For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the F.R.L. combination

More information

Super Mist Separator. Note) Rated flow (l/min (ANR)) 1 8, , , , , 1

Super Mist Separator. Note) Rated flow (l/min (ANR)) 1 8, , , , , 1 Super ist Separator Series AE an separate and adsorb aerosol state fine oil particles in compressed air and change the oil lubricating compressed air to oilless air or equivalent. Use this product for

More information

Standard Specifications. Model. Port (Bypass lubrication adapter)

Standard Specifications. Model. Port (Bypass lubrication adapter) Booster Lube Series 900 Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can

More information

Standard Specifications. Model. Port (Bypass lubrication adapter)

Standard Specifications. Model. Port (Bypass lubrication adapter) Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can be supplied. This difference

More information

5-27 A IR PREPARATION FILTERS: HIGH FLOW H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) S TOCKED AF (1 1 2) AF (2)

5-27 A IR PREPARATION FILTERS: HIGH FLOW H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) S TOCKED AF (1 1 2) AF (2) 查询 ARJ1020F-M5-06 供应商 H IGH FLOW AIR FILTER SERIES AF A IR PREPARATION 捷多邦, 专业 PCB 打样工厂,24 小时加急出货 FILTERS: HIGH FLOW 5-27 Port Sizes 1 1 2-2 Rc 5µm filter element High efficiency drainage Bowl guard standard

More information

SUB-LINE FILTERS CONTENTS

SUB-LINE FILTERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORES PRODUCTS SUB-LE FILTERS CONTENTS SUB-LE FILTERS Features, Handling Instructions and Precautions 155 Line Filters Specifications,

More information

Air Filter. Best Pneumatics 4. Equipment. Air Line

Air Filter. Best Pneumatics 4. Equipment. Air Line est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style

More information

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage. Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,

More information

ARM1000/2000. Standard Specifications

ARM1000/2000. Standard Specifications .5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction

More information

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential Air Suction Filter Series ZFA Prevents vacuum equipment trouble due to airborne contaminants. The collected dust does not remain in the case. Dust is removed easily at the time the filter element is replaced.

More information

ALB900 Series. Standard Specifications. Model. Port (Bypass lubrication adapter)

ALB900 Series. Standard Specifications. Model. Port (Bypass lubrication adapter) Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can be supplied. This difference

More information

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing

More information

5.22 A IR PREPARATION FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) AF (1 1 2) AF (2) S TOCKED

5.22 A IR PREPARATION FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) AF (1 1 2) AF (2) S TOCKED 5.22 FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF Port Sizes 1 1 2-2 Rc 5µm filter element High efficiency drainage Bowl guard standard AIR FILTER MODELS AF800/900 AIR FILTER MODELS AF811/911

More information

Ready for outdoor use too!

Ready for outdoor use too! Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type

More information

Check Valve Series AK How to Order

Check Valve Series AK How to Order High flow capacity Low cracking pressure:.2mpa Check Valve Series AK How to Order N AK 2 2 Compact and light weight Area Code Japan, Asia, Nil Australia, UK N U.S.A. 2 4 6 Body size /4 /2 /8 2 /4 3 3/8

More information

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications Speed Controller with One-touch Fitting Series Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions. Clean Exhaust Filter This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO14644-1) (* Based on SMC s measuring conditions.) Air can be directly exhausted in a clean room

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (eference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0-2 Compact type

More information

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6 ISO Standard Solenoid Valve/SIZq Rubber Seal Series VP7 6 VP7 6 FPG D VP7 6 FG D position position Single solenoid (FG-S) Double solenoids (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) Closed

More information

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard Hand Valve Series VH Specifications Fluid Proof pressure Max. operating VH00/00/00 pressure VH00 Ambient temperature and operating fluid temperature Air.5 MPa.0 MPa MPa -5 to 0 C (No freezing) VH0 VH00

More information

Air / Mist / Micro mist filter. Air Treat ent Unit

Air / Mist / Micro mist filter. Air Treat ent Unit Air / Mist / Micro mist filter Air Treat ent Unit CONTENTS WATER SEPARATOR PRECISION FILTER Page 4 MAMG Water separator Page 6 Page 8 Page 1 Page 12 MAMB MAMD MAMM MAMF 3 μm.3 μm.1 μm.1 μm + Deodorization

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description ir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. : 1/4 to 1 JIS symbol Specifications FW4000-W FW8000-W Working fluid ompressed air Max. working pressure MPa 1.0

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

How to Order. Body size

How to Order. Body size Standard Type Series N 00 Over 30 db () noise reduction Low back pressure Compact and easy mounting How to Order N 400 04 Body size 200 300 400 500 600 700 800 900 Thread type Symbol Type Nil R N NPT Symbol

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication Hand Valve VH Series VH0 Specifications VH0 Fluid Proof pressure Max. operating VH00/00/00 pressure VH0 Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa.0 MPa MPa

More information

Series IW. Filter Regulator

Series IW. Filter Regulator Standard Specifications Model IW212 IW213 IW215 IW222 Adjustable type (Basic) Fixed type Maximum supply pressure Max. 1. MPa.3 to 1. MPa Set pressure.2 to.2 MPa.2 to.3 MPa.2 to.5 MPa.14 MPa Air consumption

More information

ACTUATORS GENERAL CATALOG

ACTUATORS GENERAL CATALOG CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS PISTON TYPE SERIES CONTENTS Features 1223 Specifications 1224 Inner Construction, Major Parts and Materials 1226 Order

More information

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator Oil Filter FH150 Series RoHS ompact and lightweight The compact and lightweight design employs an aluminum alloy cover. Easy maintenance The element slides into place, making it easy to install and remove.

More information

KAMG Accessory

KAMG Accessory KAMG250~850 series Drain Separator KAMG350-04 - - 4 KAMG250-02 : Rc(PT) /4 KAMG250-03 : Rc(PT) 3/8 KAMG350-03 : Rc(PT) 3/8 KAMG350-04 : Rc(PT) /2 KAMG450-06 : Rc(PT) 3/4 KAMG550-06 : Rc(PT) 3/4 KAMG550-0

More information

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety

More information

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications Hand Valve Series Standard Specifications Fluid Standard specifications Max.operating,, pressure Ambient and fluid temperature Operating angle Lubrication Air.5MPa.MPa MPa 5 to C (No freezing) 9 Not required/when

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 Port Air Operated Valve Series SYA000/000/7000 How to Order A, B port size Thread type Thread piping (Inch size) - Rc Symbol Port size Applicable series Symbol Port size Applicable series F G SYA000 N

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable

More information

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10. Introducing GROZ Air - air control units ALUMINIUM DIE CAST BODY 01 02 WALL MOUNTING BRACKET FILTER UNIT 05 06 SINTERED BRONZE FILTERING ELEMENT (inside) 03 BUILT IN PIPING ADAPTERS PRESS TYPE MANUAL DRAIN

More information

AN 00/AN 02/AN 03/25/AN

AN 00/AN 02/AN 03/25/AN Silencer AN 00/AN 02/AN 03/25/AN Standard Series AN 00 Over 30dB(A) noise reduction Low back pressure Compact and easy mounting High noise reduction style Series AN 02 Over 35dB(A) noise reduction Case

More information

3 Port Air Operated Valve

3 Port Air Operated Valve Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard Filter Regulator IW Series Two types are available: adjustable set pressure type and fixed set pressure type. Low/High temperature and external parts copper-free types can be selected. Pressure gauge connecting

More information

AFM20-A AFD20-A. (ANR) ( 0.8 ppm) MAX 0.1 mg/m 3 (ANR) (Before saturated with oil 0.01 mg/m 3 Note 2) Note 3) Semi-standard (Steel) 0.

AFM20-A AFD20-A. (ANR) ( 0.8 ppm) MAX 0.1 mg/m 3 (ANR) (Before saturated with oil 0.01 mg/m 3 Note 2) Note 3) Semi-standard (Steel) 0. ist Separator Series F2- to F4- icro ist Separator Series F2- to F4- Standard Specifications ote 1) Conditions: Inlet pressure:.7 Pa; The rated flow varies depending on the inlet pressure. Keep the air

More information

How to Order IFW5 10 N Diaphragm Style Flow Switch to 10 l/min NPT. Port size. Specifications. Contact. Port size

How to Order IFW5 10 N Diaphragm Style Flow Switch to 10 l/min NPT. Port size. Specifications. Contact. Port size Flow Switch Diaphragm Style Series IFW5 IFW Series Flow Switches detect and confirm flow. They are applicable to general industrial machines and various other applications. How to Order IFW5 N 3 Q Low

More information

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Series PW

Series PW Series 2000300040005000 Filter Regulator Specifications H U 2000 3000 Model 2000 3000 5000 Port size Rc(PT)/NPT 1/8", 1/4" 1/4", 3/8" 3/8", 1/2" 3/4", 1" Max. Supply Pressure 1.5MPa(213 PSI) Max. Operating

More information

Air-Operated Double-Diaphragm. High Purity PTFE Pumps

Air-Operated Double-Diaphragm. High Purity PTFE Pumps Air-Operated Double-Diaphragm High Purity PTFE Pumps ULTRA High-Purity Series Ultra-High Purity Series was designed specifically for the Semiconductor Yamada s advantages come from years process of experience

More information

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03

Air Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03 In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and

More information

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1 Pressure Gauge for General Purpose Series G5/G27 G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page 663 for selection and mounting. Dimensions Port size () precision ±5% F.S. (Full span) Case

More information

Metal Processing. SMC Actuators Built to Withstand Tough Environments

Metal Processing. SMC Actuators Built to Withstand Tough Environments Metal Processing SMC products have been used in Metal Processing Applications. With SMC's vast array of pneumatic products, you are sure find the right product to meet your requirements. SMC Actuators

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

Rotary Actuator Vane Style

Rotary Actuator Vane Style Rotary Actuator Vane Style Series /:,, 2, Rotation angles:, 18, 27 Up to 27 is possible for the entire series Through the adoption of specially designed seals and stoppers, a swing angle of 27 has been

More information

SPIN-ON FILTERS & ELEMENTS

SPIN-ON FILTERS & ELEMENTS ABSOLUTE RATED (BETA SPIN ) & NOMINAL RATED SPIN-ON FILTERS & ELEMENTS Single and Twin Element Models Pressures to 20 psi Flows to 120 gpm APPLICATION HYDAC Spin-On Filters are for filtration of hydraulic

More information

Proper selection of body and sealing materials permits application of a wide variety of fluids.

Proper selection of body and sealing materials permits application of a wide variety of fluids. Direct Operated Port Valve Series A1/2 For Gas Vacuum Water and Oil Variations Proper selection of body and sealing materials permits application of a wide variety of fluids. Application can be matched

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece,, unit two piece,, Filter-regulator,,, 9 Filter-water-separator,, 9 Dust filter,, 9 Pressure regulating

More information

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations. Rotary Actuator Vane Style Series :,,,, 4 1 Series Variations Standard Vane type Port location Rotating angle Shaft type Fluid (S) ouble vane () Side ported (Nil) Axial ported (E) 9 18 27 ouble shaft W

More information

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder Power Valve 3 Position Valve Series VEX3 A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder System construction with VEX Conventional system construction

More information

F84V - Excelon Plus Modular System Oil vapour removal filters

F84V - Excelon Plus Modular System Oil vapour removal filters > Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Adsorbing type activated

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

Related Products VR4151/4152 Relay Valve

Related Products VR4151/4152 Relay Valve Related Products VR4151/4152 Relay Valve Appropriate output sequences are affected according to the signal received from the machanical valve. Specifications 1 Fluid Air Operating pressure 0 to 1.0MPa

More information

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217 1 00137795 Version Spool valve, zero overlap Sealing principle Soft sealing Mounting on manifold strip P-strip Working pressure min./max. See table below Control pressure See table below min./max. Ambient

More information

Air Preparation Products

Air Preparation Products Air Preparation Products Series Series Filter Regulator Lubricator (FRL) www.asco.com Table of Contents / Series Product Overview 2 Particulate Filter 4 Coalescing Filter 8 Adsorber Activated Carbon 8

More information

SP/SF Series Flow Switches

SP/SF Series Flow Switches ISO-9001:2000 certified SP/SF Series Flow Switches More than just another level measurement company. Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION SP SERIES OPERATING PRINCIPLE SP SERIES The SP Series

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type /3000 Series modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new knob. lso has a One-touch lock

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order Direct Operated Regulator for 6.0 MPa (Relieving Type) VCHR Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high pressure

More information

FLUID COOLING Shell & Tube B Series

FLUID COOLING Shell & Tube B Series FLUID COOLING Shell & Tube Series WATER COOLED COPPER & STEEL CONSTRUCTION Features Young Touchstone Interchange Optional Non-Ferrous Construction Competitively Priced 1/4 or 3/8 Tubes Standard Water to

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS Compressed Air Filters 15-1600 scfm FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES Z E K S Z T F C O M P R E S S E D A I R F I

More information

Series SYA3000/5000/7000

Series SYA3000/5000/7000 1 Port Air Operated Valve Series SYA000/000/7000 Body ported Base mounted Base mounted How to Order A, B port size Thread type Thread piping (Inch size) Nil Rc Symbol Port size Applicable series Symbol

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Gerotor pump, fixed displacement volume

Gerotor pump, fixed displacement volume Gerotor pump, fixed displacement volume RE 10545/12.11 1/12 Type GZ Component series 1X Maximum operating pressure 15 bar Maximum displacement 140 cm³ H7572_d Table of contents Contents age eatures 1 Ordering

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

MAINTENANCE GUIDE Rotary joint

MAINTENANCE GUIDE Rotary joint MAINTENANCE 7. Filter in Cooling System Cleaning interval Replace earlier if badly contaminated. Heater performance will deteriorate if used for a long period of time without cleaning or replacement. Clogging

More information

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications Manifold Regulator Modular Type Series /3000 modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new handle. lso has a Onetouch

More information

MOISTURE MEETS ITS MATCH

MOISTURE MEETS ITS MATCH Donaldson Delivers T.R.A.P. Breather Technology For Hydraulic and Lube Oil Reservoirs MOISTURE MEETS ITS MATCH Donaldson T.R.A.P. breathers collect and expel the moisture out of reservoirs, which means

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center) Hand Valve Series VH Specifications VH VH Fluid Proof pressure Max. operating VH// pressure VH Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa. MPa MPa 5 to C

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Filters, Gauges, Regulators

Filters, Gauges, Regulators Filters, s, Regulators SCFM = Cubic ft/min at Ambient Condition s Sold Separately s...1/4" Flow SCFM...21 s...1/4" Flow SCFM...15 Filters - Construction Mini 1/4" 3000 Regulators Without Mini 1/4" 3100

More information

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g. Speed Controller with One-touch Fittings In-line In-line Type y Easo t use RoHS Brass Stainless steel Reduces flow setting time! Push-lock type Knob O.D.: Almost doubled! Easy to lock ø9.4 Unlock ø5 Lock

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 1507-18 mm - pad mounting body M1 connection x/ - 5/ - 5/ Series 50 ISO 1507- (18 mm) FEATURES M1 connection with electrical

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters High Pressure fi lters FHF5 series Maximum pressure up to 50 bar Flow rate up to 500 l/min housing according to SAE J066 for HF filter s 95 High Pressure fi lters FILTER SIZING The correct filter sizing

More information

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information

Rubber Seal VP300/500/700

Rubber Seal VP300/500/700 Port Pilot Operated Poppet Rubber Seal 00/500/700 High flow capacity Cv1.0 (00), Cv. (500), Cv.0 (700) Low power consumption: 1.8W(DC) Possible to use as either selector valve or divider valve Changeable

More information

DR Series Radial Diaphragm Valves

DR Series Radial Diaphragm Valves DR Series Radial Valves Service Instructions Valves with Plastic Actuators (1/2 through 1 inch) Valves with Aluminum Actuators (1/2 through 2 inch) Manual model Pneumatic model Manual model Pneumatic model

More information