Accessory Valves. Frequently Asked Questions

Size: px
Start display at page:

Download "Accessory Valves. Frequently Asked Questions"

Transcription

1 Flow Control Frequently Asked Questions What is the difference between your Accessory Valves and others I already use? Vektek Accessory Valves are sized for the normal flows and conditions present in hydraulic clamping sys tems. They are not intended for use in general industrial equipment as they are specifically intended for clamp ing. Maximum intended flow rate on any Vektek Accessory Valve is 1.5 gpm (unless otherwise noted). Excessive flows may cause damage or erratic behavior. General industrial products are intended for use in large flow applications (typ i cal ly 2 gpm +). These general industrial products do not normally work well in clamping systems. What is the function of a pressure limiting valve? Relative to a Relief Valve? Limiting Valves limit the pressure that can pass through the valve. When they reach their preset pressure, they close off to prevent further increase in downstream pressure. Relief Valves are intended to guard against excess pressure. When a circuit builds beyond the setting of a PRV, it opens and excess pressure is relieved from the system. If a relief valve is set below the pressure switch adjustment of a pump, the pump will kick on and off frequently. Incorrect adjustment of a Pres sure Relief Valve can cause ex pen sive damage to your pump. Explain why you don t want me to put a group of Sequence Valves in series. When a group of Sequence Valves is put in series they have to work harder than if they are fed parallel from a single main feed line (see drawing on page M-6). Vektek Sequence Valves modulate as fluid passes through them, trying to maintain upstream pressure. The interruption of fluid flow through one valve will adversely effect the modulation of the next valve in line, resulting in erratic performance. You may put as many Sequence Valves in parallel as you wish. We recommend approximately 500 psi difference in their settings for ease of installation. What is the difference between your ball valve and the screw down valves I can buy locally? Our shutoff Ball Valves close a circuit and maintain that seal until rotated and pressure is released later. They are intended for applications that will not allow for leakage or are repetitive. They change from closed to full open with 1/4 turn of the handle. Explain why I might select one filter over another. Vektek offers three styles of filter. The first type is In-line Filter (available in 10 or 25 micron filtration), designed and sized to be used in-line where fine filtration is desired to help protect devices (restricted to a maximum flow rate of 3 gpm) making this unit particularly flexible in meeting your design criteria. You can also mount these filters directly into the device ports of sensitive valves and components to guard against contamination. The second style is the Basic Filter which is also available in 10 and 25-micron filter ratings. These filters catch small debris and are intended for high contamination systems. The larger filtering surface allows this unit to accept up to 7 gpm and handle larger quantities of chip contamination before maintenance. The frequency of maintenance is determined by the amount of contamination present in your system. Simple flushing will often improve the flow through these filters when performance becomes obviously limited. Our third type of filter element is an In-line Screen Mesh. This filter is intended to catch the big chips (180 micron rating). At fixture assembly, it is easy to forget to clean the I.D. (inside diameter) of the tubing before introducing oil to the plumbing. Tubing and manifold passages may contain chips, dirt, cobwebs, tape or paper. These contaminants will break loose and lodge in a valve resulting in valve failure. By using these chip catchers you can reduce expense and can make your system more dependable. Standard Features Common Features: Sequence, Pres sure Relief, Limiting and Reducing Valves Material: All cartridge com po nents are steel, operating parts are hardened. Operating Media: Conventional, petroleum based, premium quality hy drau lic fluid such as VektorFlo , see page J-1. Recommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum). Adjustments: Turning adjustment screw clockwise (when viewed from ad just ment end of cartridge) increases pressure setting on all valve styles. NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves unless otherwise indicated. Excess flow voids warranty. M Vektek, February 2017

2 Flow Control Precision In-line Flow Control Micro metering adjustment of master system with 1/64 inch pitch needle valve. Protect sensitive components from excessive flow. System control. Flow controls used as meter-in devices in clamping systems to prevent damage. Flows up to 3 gal/min at 5,000 psi maximum pressure. Check valve for reverse free flow. Available in SAE 4 or SAE 6 port sizes. Stainless steel inner valve construction. Fluorocarbon seals are standard. Locking adjustment knob. In-line Flow Control A Port B Port SAE 4 SAE SAE 6 SAE 6 M-2 Precision In-port Flow Control Use with Single or Double Acting clamps. Meter-in flow control with reverse free flow check valve. Smallest high-pressure flow control valve on the market. Prevent component cam damage from unexpected or accidental surges in flow rate. Adjusting screw is positively retained and will not come out under pressure. Flow control requires the use of manifold mount ports. Consult the double acting work support, the swing clamp or link clamp specifications page for the valve that is appropriate for your application. In-Port Flow Control Cavity In-Port Flow Control Port A Size Max B Hex C Hex D E SAE SAE SAE SAE Port Size A B C D E F G H J SAE /16-24 UNF SAE /16-20 UNF SAE /16-20 UNF SAE /16-20 UNF NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in./ minute) for all VektorFlo special function valves unless otherwise noted. Excess flow voids warranty. Vektek, February

3 Shutoff Valve Ball valve designed for positive shutoff op era tion. Handle is easily moved, even under maximum pressure. Straight handle available order Part Shutoff and Check Valves Precision, steel components and molded spherical seats provide a positive seal to isolate your fixture. Use with hydraulic junction manifolds on page I-1 and I-2 for secure fixture mounting. NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in./ minute) for all VektorFlo special function valves unless otherwise noted. Excess flow voids warranty. Shutoff Valve A Pilot Operated Check A Pilot Operated Check Valve Sealed pilot piston eliminates cross circuit leakage. 5:1 Ratio of Pilot to Check pressure for release. Filters on each port location. Unclamp device sequencer, provides a way to sequence single circuit unclamp timing. Requires a B pilot to open A line check valve (requires a double acting control valve to operate single acting systems) Stainless steel inner valve construction. Maximum operating pressure 5,000 psi M-3 NOTE: Field repair requires a special Check Valve Installation Tool. Please order For proper sealing, mating surface must be flat to in. with a maximum 63 μ in. R a surface finish Vektek, February 2017

4 Pilot Operated Check Valve M-4 Pilot Operated Check Valve Cartridge and Manifold Mount versions. Sealed pilot piston eliminates cross circuit leakage. 5:1 Ratio of Pilot to Check pressure for release. Unclamp device sequencer manages single circuit unclamp timing. Flows up to 1.5 gal/min at 5,000 psi maximum pressure. Assembly Dimensions A B C D E F G H J K L M SAE 6 SAE 2 Plug N/A N/A 0.94 N/A Mounting Dimensions for Pilot Operated Check Valve Assemblies and For proper sealing, mating surface must be flat to in. with a maximum 63 µ in. R a surface finish. Vektek, February

5 Pilot Operated Check Valve PO Cartridge Cartridge Mount Pilot Operated Check Valve Cavity Dimensions L M-5 Changeable with Standard Cavity Port Tooling. Contact Vektek for details Vektek, February 2017

6 Check Valves A-B Check Valve Sealed pilot piston eliminates cross circuit leakage. 5:1 Ratio of Pilot to Check pressure for release. Filters on each port location. Manifold mounted. BHC body and stainless steel internal components for corrosion protection. A-B Check Valve For proper sealing, mating surface must be flat within in. with a maximum 63 μ in. R a surface finish. NOTE: applied to the A inlet port flows to the A outlet port and unlocks check on the B side allowing pressure on B to return to tank. applied to B inlet flows to B outlet and unlocks check on A side allowing pressure on A to return to tank. Field repair requires a special Check Valve Installation Tool. Please order M-6 Check Valves Permits flow in one direction only. Can not be adjusted for reverse flow. NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves. Excess flow voids warranty. Check Valve Check Valve Dimensions A B C SAE SAE 6 Vektek, February

7 In-line Filter Available in two port sizes and two filter ratings. Filters at 5,000 psi in either direction. Compact in-line design for maximum flexibility. Protects sensitive valves and devices from contamination. Serviceable for cleaning or filter replacement. Maximum flow 3 gpm. Maximum ambient temperature of 200 F. Can also be used for in-line application. In-line Filters, Basic Filters and Filter Screens In-line Filter Dimensions A B C D E F G H SAE 4 SAE 4 10 Micron SAE 4 SAE 4 25 Micron SAE 6 SAE 6 10 Micron SAE 6 SAE 6 25 Micron Screen replacement kits available. Call factory for details Adapter Filter Installs easily into SAE 6 Quick Disconnect. Installs into Quick Disconnects of Pallet Decouplers providing extra filtration. Adapter Filter Filtration Micron M-7 In-port Filter Installs easily into SAE 6 manifold ports. Installs in manifold ports of Pallet Decouplers for additional filtration. In-port Filter Filtration Micron Vektek, April 2017

8 Check Valves Basic Filter Keeps chips and debris from reaching valves or other sensitive devices. Traps contaminants which may have been missed when cleaning tubing or blind holes prior to fixture startup. Easily cleaned or changed filter should be checked when devices become sluggish. Basic Filter Filtration Micron Micron Basic Filter Drop Gal/Min 25 Micron 10 Micron Screen replacement kits available. Call factory for details In-line Filter Screens SAE 4 Filter Screen Protects valves and devices installed at pump. Catches damage causing chips. Can be used in in-port applications. M-8 In-line Filter Screens Port SAE SAE 6 SAE 6 Filter Screen Protects devices and individual valves. Catches damage causing chips. Can be used in in-port applications. Vektek, February

9 Unclamp Delay Valve Temporarily Hold Parts During Unclamp Set delay to control unclamp in single acting devices. Use in single or double acting systems. Eliminate workpiece movement, caused by backpressure, when unclamping over a work support. Normally open valve allows free fluid flow through the valve during clamping. Does not require B pilot line to open. Stainless steel internal components for superior corrosion resistance. Unclamp Delay Valve * Set Range** Time Delay Preset*** (sec.) Filtration Included Max Flow Patent Pending to 5,000 psi 3 to 7 seconds Using ISO 32 Fluid Crossover plate, , needed when using as a standalone manifold mount valve. * Manifold mount o-rings included. Ships with all ports plugged. ** Maximum inlet pressure 5,000 psi. Excess pressure voids warranty *** Duration of time delay may vary depending on the viscosity of oil in the application. If longer delays are required (up to 20 sec.), contact Vektek Customer Support for assistance. Mounting Options 25 micron All Ports 3.0 gpm Operation: The VektorFlo Unclamp Delay Valve operates as a normally open element in an hydraulic clamping system. Low pressure fluid flows freely through the valve to downstream devices. As pressure in the system builds, the mechanical pilot piston moves away from the check valve allowing it to close. Full system pressure is reached and flow in the system stops. If pressure leaks off in downstream devices, the check valve will re-open and replenish pressure. During unclamping, inlet pressures falls with main system pressure but downstream pressure is held constant by the check valve. At the low inlet pressure, spring force starts to move the mechanical pilot towards the check valve at a rate set by the flow control and oil viscosity. The mechanical pilot piston moves through its stroke and encounters the check valve. Spring force opens the check to release all downstream pressure to the power unit reservoir. M-9 For proper sealing, mating surface must be flat to in. with a maximum 63 μ in. R a surface finish Vektek, February 2017

10 Sequence Valve Sequence Valve Control the timing of fixture devices. Specialized construction resists corrosion which can cause other styles to misfire. Direct acting poppet style con struc tion. Manifold mountable. Cartridge may be installed directly into your manifold. Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system res er voir. True sequence design allows full system pressure downstream of valve after opening. Recommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum). DON T DO Operation: The VektorFlo sequence valve operates as a pressure sensitive, normally closed element in a clamp ing system. When fluid first enters the sys tem at low pressure, the valve is closed, blocking the flow of fluid to devices downstream. After devices in the other branches of the system have moved into position, the pressure begins to increase. The in creas ing pressure overcomes the spring force holding the valve closed, forcing the poppet off its seat, and al low ing fluid flow through the valve. After all devices have positioned and clamped, the downstream pressure increases to equal upstream pressure. throughout the system will increase to the maximum setting on the hydraulic power supply. When un clamp ing, as pressure falls, force from the adjustment spring pushes the poppet back onto its seat. Fluid trapped in the downstream circuit flows back through the check seat to return to the power unit reservoir. Sequence Valve Set Range A B Max Flow to 900 psi gpm to 5000 psi gpm *Maximum Inlet for sequence valve is 5,000 psi, excess voids warranty. M-10 For proper sealing, mating surface must be flat to in. with a maximum 63 μ in.r a surface finish. Vektek, February

11 Sequence Cartridge NEW SET RANGE More flexibility Sequence Valve Cartridge Set Range A B Max Flow to 900 psi gpm to 5000 psi gpm * Maximum Inlet for sequence valve is 5,000 psi, excess voids warranty. Sequence Valve Cartridge Cavity A A Thread M20 X Min..002 A 63 Minor A.004 A ± ± ± ±5.656± M ± Sequence Outlet 30 ± A ± Inlet ILS REV G Multi-Step Carbide Cavity Contour Tool with Tap Kit Reamer and M20 x 1.5 tap NOTE: If a sequence valve is no longer needed, use plug, to cap cavity for free fluid pass through Vektek, January 2018

12 Combination Sequence/PRV Block Timing and Regulated in One Unit Efficient Space Saving Combination Sequence/PRV Block Control both timing and pressure with this dual purpose combination block. Common inlet port feeds both sequence and reducing valves. 3 (SAE 2) manifold ports: Inlet, Sequenced and Sequenced+Reduced. 6 (SAE 4) ports: 2 x Inlet, 2 x Sequenced and 2 Sequenced +Reduced. Use with single or double acting devices. Block includes standard Sequence and PRV cartridges. Direct acting poppet style valve construction. Sequence adjustment range: 750 psi to 5,000 psi, PRV adjustment range: 750 to 4,500 psi. Enough space is provided on the block to accommodate a Gauge for setup or trouble shooting. Recommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum). Combination SEQ/PRV Assembly Sequence Valve Sequence Valve Set Range PRV PRV Set Range psi psi psi psi** psi psi psi psi** * SAE 2 Ports are counterbored for o-rings that are used in manifold mounting applications. Ø 0.09/0.15 feed holes. ** PRV set pressure is: psi with an inlet pressure of < 3000 psi psi with an inlet pressure > 3000 psi A B For proper sealing, mating surface must be flat within in. with a maximum 63 μ in. R a surface finish. M-12 NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves, unless noted. Excess flow voids warranty. Vektek, February

13 Reducing Valve Reducing Valve Control pressure to individual devices. For use in double or single acting systems. Direct acting, poppet style, adjustable, cartridge construction. Cartridge may be installed di rectly into your manifold set the pressure range from 750 to 4500 psi. Repeatability ± 7% set the pressure range from 150 to 900 psi. Repeatability ± 10% Maximum inlet pressure 5,000 psi. Reducing Cartridge is interchangeable with the Limiting Cartridge in the same mounting cavity. Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. n Recommended Filtration: 25 Mi cron (NOM) /40 Micron (ABS) (mini mum). U. S. Patent 5,931,182 See page M-15 for cartridge cavity dimensions. Reducing Valve Inlet Set * Range Repeatability A Manifold Mount Valve Assembly psi 750 to 4500 psi ± 7% < 3000 psi 150 to 900 psi >3000 psi 300 to 900 psi ± 10% 6.5 *Maximum Inlet for PRV is 5,000 psi NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves, unless noted. Excess flow voids warranty. Operation: The Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point. For proper sealing, mating surface must be flat within in. with a maximum 63 µ in. R a surface finish. Repeat Range (PSI) The graph shows the repeat range based on set pressure Set (PSI) ILS REV D M-13 Differential (PSI) The graphs show the pressure drop through a PRV and manifold mount block Drop vs Flow Flow (gpm) ILS REV E Vektek, May 2017

14 Reducing Control Block PRV Control Blocks Control pressure independently on both the clamp and unclamp side of the fixture regardless of pump pressure setting. Eliminate the wait for full system pressure to finish cycling workholding components. For use in double or single acting systems. DO3 Mounting, use on pump stack or as a remote mounted valve. Recommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum). Dual PRV Control Block Inlet Set * Range Repeat A B Manifold Mount Valve Assembly psi 750 to 4500 psi ± 7% < 3000 psi 150 to 900 psi >3000 psi 300 to 900 psi ± 10% *Maximum Inlet for PRV is 5,000 psi M-14 Single PRV Control Block Inlet Set * Range Repeat A Manifold Mount Valve Assembly psi 750 to 4500 psi ± 7% 3.7 < 3000 psi 150 to 900 psi ± 10% 4.4 >3000 psi 300 to 900 psi *Maximum Inlet for PRV is 5,000 psi NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves, unless noted. Excess flow voids warranty. Vektek, February

15 Limiting Cartridge and Reducing Cartridge Cavity See product Page M-15 Reducing Cartridge Inlet * Set Range Repeatability A B psi psi ± 7% <3000 psi psi ± 10% >3000 psi psi * Maximum Inlet for PRV is 5,000 psi Repeat Range (PSI) Limiting Cartridges Limit Limit Limit Limit A A A Minor Dia /8-14 UNF.62 Min.002 A.100±.005 M Set (PSI) ILS REV D Limiting Cartridge and Reducing Cartridge use the same mounting cavity ± ± ± ±5 R ± ±.010 NOTE: For cavity tooling (multistep Reamer), order kit If a PRV/PLV is no longer needed, use standard SAE#10 plug, , to cap cavity for free fluid pass through High Inlet Lower Outlet A ILS REV E Vektek, June 2017

16 Limiting Valve Limiting Valve Recommended for use in single acting systems only. Direct acting, poppet style, ad just able, cartridge type construction. Cartridge may be installed di rectly into your manifold. All pressure limiting valve configurations are designed to operate with up to 5,000 psi on the inlet (P) port. Seal Material: Internal seals are nylon. Internal adjustment discourages tampering with pressure adjustment setting. Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. Recommended Filtration: 25 Mi cron (NOM) / 40 Micron (ABS) (mini mum). Operation: The Limiting Valve (PLV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At set-point pressure the valve closes, blocking further flow and pressure rise to the downstream devices. The internal valve seal prevents fluid flow through the valve in either direction until the inlet pressure (power source to the valve) is reduced to near zero. NOTE: Maximum system flow rate is 1.5 gpm (346.5 cu. in. per minute) for all VektorFlo special function valves unless otherwise noted. Excess flow voids warranty. For proper sealing, mating surface must be flat within in. with a maximum 63 μ in. R a surface finish. Adjustment Ranges Limiting s Range 750 psi to 2,500 psi 1,000 psi to 3,500 psi 1,500 psi to 5,000 psi DON T DO Factory Preset Cartridge 1,000 psi ,500 psi ,000 psi M-16 Vektek, February

17 Non-Powered Waterproof Switch No power required. Ideal when you need to add a pressure switch to a remote location as on a machining pallet fixture. Switch tested to over 1,000,000 cycle lifetime. New sealed collar and micro-switch design guard against leaks; making this switch ideal for use in wet environments. adjustment 750 to 5,000 psi. Electrical Rating VDC resistive /250 VAC Reset deadband: approximately 5% of the set pressure. Sealed switch for operation in high moisture environments. (Complies with IP 67) Switch Range Electrical Connection psi M8 Male Connection only psi psi psi psi Part cordset, 39.3 in. long with female M8 connector and bare ends. Part cordset, 19.7 in. long with M8 male and female connections. Part cordset, 16.4 ft. long with M8 female connector and bare ends. Part cordset, shielded, 19.7 in long with M8 male and female connections. Switch Wiring Instructions Pin 1.. N/O Pin 4.. N/C Pin 3..Common Brown... N/O Black... N/C Blue... Common Pin 1.. N/O Pin 4.. N/C Pin 3..Common Brown.. N/O Black.. N/C Blue.. Common Pin 1.. N/O Pin 4.. N/C Pin 3.. Common Powered LED Display Electronic Switch Large 4 digit LED pressure display. Requires power (15-32 VDC). Programmable deadband. Easy 3-Button programmable electronic pressure switch. 2 digital switching outputs, 500 ma Rating, PNP only. Single analog output, 0-10 V or 4-20 ma. Set pressure range of psi. Programmable reset pressure for each output. Sealed switch for operation in high moisture environments. Complies with IP 67 or Nema Rating 6. M-17 Plug Pin Pin 1, Brown Pin 2, White Pin 3, Blue Pin 4, Black Pin 5, Gray Set Range Input/Output VDC Analog 0 V SP1 0.5 A MAX SP2 0.5 A MAX Electrical Connection Power Supply Power Consumption M12 Male 5 Pin VDC 50 ma Description 2 Digital Contacts Programmable N/O or N/C End 1 Connection 1 Analog Output Programmable 0-10 V or 4-20 ma End 2 Connection Media Temp. Range -13 to +212 F Length (ft.) Male 90 Female Cable, M Male Straight Female Straight Pin Male Straight Female Straight 16.4 PUR Black Male Straight Female Straight Vektek, April 2017

18 Hydraulic Gauges, Over Relief Standard Gauges Liquid filled gauges with analog readouts. Avalible in 1,500 to 10,000 psi. Conform to ANSI standard B40.1 Grade B. SAE 4 male connection. Safety Glass Window. Standard Gage Range Bezel Diameter (in) to 1,000 psi to 3,000 psi to 5,000 psi to 10,000 psi 2.7 Back Mount Gauges Liquid filled gauges with analog readouts. Avalible in 1,500, 5,000, 6,000 and 10,000 psi. Conform to ANSI standard B40.1 Grade B. SAE 4 male connection. Safety Glass Window. To extend the life of Gauges, run your system at no more than 75% of the gauge scale. Back Mount Gauge Bezel Range Diameter A (in.) to 1,500 psi to 6,000 psi to 5,000 psi to 10,000 psi 2.7 A SAE M-18 Over- Relief Cartridge Cartridge will open to bleed off excess pressure in the event of over-pres suri za tion (above 6,000 psi). Screw in cartridge adds an extra element of con fi dence in your self-designed systems. SAE 4 male connection. Over- Relief Cartridge ILS REV J Vektek, January

19 NEW Confirm Clamp Stroke Position Pneumatically The pneumatic confirmation valve confirms the stage of loading before or after clamping. It is adaptable to multiple devices including: swing clamps, link clamps, cylinders and supports. Avoid machine crashes by confirming specific actions before you cycle your machine. It is designed to be used in both coolant and dry environments, and is easily mounted either vertically or horizontally. Confirmation at its finest! Easily fine tune your fixture choosing between set and differential pressure. Confirm signal is based on restricting air flow when testing function is present. Over-travel sensing will reopen if a device depresses plunger beyond the valve limit. Use Pneumatic Confirmation Valve with almost any clamping device. Assists in detecting missing or incorrectly loaded parts. Remote venting recommended in coolant applications. Feedback to machine automations and robotics through the pressure switch. 1/8 tube - M3 Connector Part P , Order separately. Application Setup: Adjust actuator 0.025± above valve body with clamp positioned at the bottom of clamping stroke. This will avoid valve and actuator damage if clamp over travels. For proper sealing, mating surface must be flat within in. with a maximum 63 µ in. R a surface finish. Pneumatic Confirmation Valve, Block NOTE: Mounting hardware not included. E= Input A= Output (vent to atmosphere) E= Input A= Output (vent to atmosphere) Pneumatic Confirmation Valve Description Over-Travel Sensing Max Air (psi) Operating Range (psi) Air Flow Rate (SCFM) Differential * 20 psi System 70 psi System Plunger Stroke (in) Spring Force (lbf.) Nominal Diameter (in.) Min. 12 Min Max Standard Min. 12 Min Max * drop when one or more valves open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel. Port Types Manifold and M3 Manifold and M3 M X5-00 Over Travel Sensing Transi on Range 50-40X5-00 Over Travel Sensing Logic ON CLAMPED OFF Swing Clamp Stroke Example Swing Stroke.08".325".350 Valve Stroke 0.40" Clamping Stroke More detail on recommended layout can be found on page B X5-01 Standard Logic ON CLAMPED OFF Swing Clamp Stroke Example 50-40X5-01 Standard Swing Stroke Transi onrange.08" Valve Stroke 0.40" Clamping Stroke ILS Vektek, March 2018 Rev C

20 Pneumatic Confirmation Valve, Cartridge Pneumatic Confirmation Valve Cartridge Description Over-Travel Sensing Max Air (psi) Operating Range (psi) Air Flow Rate (SCFM) Differential * 20 System 70 System Plunger Stroke (in) Spring Force (lbf) Nominal Diameter (in) Min. 12 Min Max Standard Min. 12 Min Max * drop when one or more valves open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel..787 Port Types Manifold and M3 Manifold and M3 M Outlet port allowable to connect at any angle to these surfaces.020± ± ± MAX OUTLET PORT M12 X 1.5 6H MAX INLET PORT Inlet port allowable to connect at any angle to these surfaces ILS REV B Vektek, June

NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve

NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve PRECISION HYDRAULIC CLAMPING NEW PRODUCTS sales@vektek.com www.vektek.com 800-992-0236 NEW PRODUCTS Metric Slip-in Cartridge 360 Link Clamp The BEST Link Clamp Innovation Ever... NOW AVAILABLE IN: INCH

More information

Contact Force (lb.) Stroke (in.) Fluid Advance Work Supports, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks 0.

Contact Force (lb.) Stroke (in.) Fluid Advance Work Supports, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks 0. B-21 For Retracted Plunger Applications Available in three capacities 1,000, 2,500 and 4,000 lb. Normally retracted plungers do not interfere with part loading. them with hydraulic pressure, exerting only

More information

Palletized Fixture Accessories

Palletized Fixture Accessories Frequently Asked Questions Some questions about pallet and tombstone clamping systems are common to both novices and experienced users. The answers to the following questions may help you better understand

More information

Miscellaneous Plumbing

Miscellaneous Plumbing Manifolds Manifolds Four different styles to work in your par ticu lar system. SAE straight thread o-ring ports used exclusively to provide drip free hydraulic connections. High strength steel, careful

More information

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS.

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS. Copyright 986-208 209 by Vektek, Inc. 2 THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL 50-4085-00 AT REVISION C AND LATER REVISIONS. 2 2X APPLY LOW STRENGTH THREAD LOCKER TO THREADS. TIGHTEN

More information

TuffCam Swing Clamps C-1. Frequently Asked Questions

TuffCam Swing Clamps C-1. Frequently Asked Questions TuffCam s Frequently Asked Questions C-1 When do you recommend the use of TuffCam s over the standard product? Applications where speed is essential, massive arms are required, or position sensing is necessary,

More information

Cylinders. Standard Features F-1. Frequently Asked Questions, Features

Cylinders. Standard Features F-1. Frequently Asked Questions, Features Frequently Asked Questions, Features Why use Cylinders? Cylinders are the most common and least costly form of hydraulic clamping avail able. They can be sized adequately to allow you to clamp across or

More information

VEKTEK PARTS LIST. Copyright by Vektek, Inc.

VEKTEK PARTS LIST. Copyright by Vektek, Inc. Copyright 986-208 by Vektek, Inc. 2 THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODELS 45-0485-00 & L5-0485-00 AT REVISION B AND LATER REVISIONS. 4 2 2X APPLY LOW STRENGTH THREAD LOCKER TO

More information

TuffCam Swing Clamps C-1. Frequently Asked Questions

TuffCam Swing Clamps C-1. Frequently Asked Questions Frequently Asked Questions C-1 When do you recommend the use of TuffCam Swing Clamps over the standard product? Applications where speed is essential, massive arms are required, or position sensing is

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : TAP- IN KIT 5100-5151 BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C., 29605 FAX:

More information

Push/Pull Cylinders G-1. Frequently Asked Questions. Frequently Asked Questions, Features

Push/Pull Cylinders G-1. Frequently Asked Questions. Frequently Asked Questions, Features Frequently Asked Questions, Features G-1 Frequently Asked Questions What is the intended application of these devices? They are intended for use actuating remote mechanisms, pulling on clamp plates, or

More information

Power Supplies. Hydraulic Oil ISO 32 Grade

Power Supplies. Hydraulic Oil ISO 32 Grade Frequently Asked Questions I have a pump on my machine. Can I use it to drive my clamps too? Yes, you may use a machine pump to drive your clamping system if it has the following characteristics: 1) It

More information

TuffCam 7 MPa Swing Clamps

TuffCam 7 MPa Swing Clamps TuffCam 7 MPa Swing Clamps Frequently Asked Questions C-1 When do you recommend the use of TuffCam 7 MPa Swing Clamps over other Vektek product? Sometimes there are applications where speed is essential.

More information

Pressure Control Valves

Pressure Control Valves Catalog HY15-351/US Contents RELIEF VALVES SEQUEN VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/ DIRECT ACTING RDH42... C4-2... Direct Acting Relief, Poppet Type... 3.8/1...

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides

More information

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-352/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2B2YP... C8-2...

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Catalog HY15-351/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI PRESSURE RELIEVING AP1B2YP... 2G... Increase /Increase Current...5.3/1.4... 35/5... 7-8 AP2A2... C8-2... Increase

More information

Pressure Control Valves

Pressure Control Valves CV Catalog HY15-3501/US Contents RELIEF VALVES SEQUEN VALVES Control SERIES CAVITY DESCRIPTION FLOW PRESSURE LPM/GPM BAR/PSI DIRECT ACTING RDH042... C04-2... Direct Acting Relief, Poppet Type... 3.8/1...

More information

We shut the air supply down to our clamps once they are in position. Sometimes we notice that they are sticking. Could this be the cause?

We shut the air supply down to our clamps once they are in position. Sometimes we notice that they are sticking. Could this be the cause? Frequently Asked Questions B-1 Following are some of the questions we have been asked while developing the VektorAir TM line. Please read them carefully before planning your system. Many common problems

More information

FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION

FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION This is an uncontrolled document provided for informative purposes only. Product information contained herein is subject to change without notification

More information

Pressure Sensor No Series

Pressure Sensor No Series Sales Manual Section 335 PRODUCT SPECIFICATION 84372 SERIES Pressure Sensor No. 84372-Series GENERAL DESCRIPTION The patented* No. 84372-Series Pressure Sensor contains a weatherproof, snap-acting valve

More information

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Bulletin 0700-B3 ENGINEERING

More information

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital) IN64124 August 15, 1997 Aerospace Group Conveyance Systems Divison Carter Brand Ground Fueling Equipment Applicable additional manuals: Installation Instructions Inline Pressure Control Or Shutoff Valves

More information

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Catalogue PDE675TCUK October

More information

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description Catalog HY-351/US Information Cartridge Style Valve. For additional information see Tips on pages 1-4. Valve Series H13P Spherical poppet for low leakage D -Ring eliminates back-up rings Dual sense paths

More information

12CS/50CS Series Coreless Medium Pressure Filters

12CS/50CS Series Coreless Medium Pressure Filters 12CS/5CS Series Coreless Medium Pressure Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

DRV2-080 Adjustable, Direct-Acting Relief Valve

DRV2-080 Adjustable, Direct-Acting Relief Valve SOLENOID DRV2-080 Adjustable, Direct-Acting Relief Valve SERIES 8 CHECK MOTION FLOW USASI / ISO ➁ ➀ DESCRIPTION An adjustable, direct-acting poppet cartridge valve designed to limit pressure in hydraulic

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

SECTION Pressure & Temperature Control

SECTION Pressure & Temperature Control 16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

Check List for Optimal Filter Performance

Check List for Optimal Filter Performance Check List for Optimal Filter Performance There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and a 1.5" or 2 valve should have a 3 waste line. Do not use rubber hosing

More information

12CS/50CS Series. Coreless Spin-on Filters

12CS/50CS Series. Coreless Spin-on Filters 12CS/5CS Series Coreless Spin-on Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.

More information

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Check valves Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Check valves CHECK VALVES... -4 FPR -

More information

SERIES HH WITH HYDRAULIC ROD LOCK

SERIES HH WITH HYDRAULIC ROD LOCK HH LOCK TAB HH Rod Lock HH Options SERIES HH WITH HYDRAULIC LOCK The TRD difference... TRD s floating rod bushing design and RL Series Rod Lock = OPTIMIZED RESULTS and SUPERIOR PERFORMANCE. For rod locks

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps Power Clamping Repair Kits... 213 Rotary Couplers...208 Swing Cylinder Arms... 150 Swing Cylinder Bottom Flange... 149 Swing Cylinder Top Flange... 148 Tubing, Steel... 212 Valves, Air Circuit... 202 203

More information

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2-10 MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls

More information

ADVANTAGE PLUS Installation Instructions

ADVANTAGE PLUS Installation Instructions ADVANTAGE PLUS Installation Instructions TABLE OF CONTENTS Electrical Controls... 3 Electrical Sensors... 4 Hydraulic Component Breakdown... 5 Tank Enclosure / Mounting Recommendation... 6 Hydraulic Installation

More information

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5 Anchor Applicator Model BAAM HYDRAULIC CONTENTS EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5 PRESSURE SETTINGS General Settings and Locations of Manifolds...H-5 Main System Pressure and Relief...H-6

More information

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160

More information

Operating Instructions & Parts Manual

Operating Instructions & Parts Manual Operating Instructions & Parts Manual Grainger Model No. 36NE14 Bucher Hydraulics Model No. M-4509-0217 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description:

More information

POWER CLAMPING.

POWER CLAMPING. www.jergensinc.com POWER CLAMPING Air Circuit Controls- 2-Hand No Tie Down....59 Booster Clamping Kit....49 Boosters, High Pressure/Volume....47 Booster Installation Kits....48 Boosters, Pre-Fill....44

More information

Heavy Duty Hydrostatic Transmissions

Heavy Duty Hydrostatic Transmissions Heavy Duty Hydrostatic Transmissions Features and Benefits Typical Applications Construction Transit Mixer Road Roller Paver Motor Grader Loader Dozer Material Handling & Utility Crane Sweeper Lift Truck

More information

Pressure Regulators RHPS Series

Pressure Regulators RHPS Series Pressure Regulators Series 1 www.swagelok.com Pressure Regulators Series Pressure-reducing models Back-pressure models Spring-, dome-, and air-loaded 1/4 to 4 in. end connections Working pressures up to

More information

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf LF(M) High Viscosity Filter Assemblies Low pressure filter assemblies optimized for high flow hydraulic, high viscosity lube and heavily contaminated fuel applications. Max Operating Pressure: 150 psi

More information

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP BALL VALVES TABLE OF CONTENTS MAINTENANCE AND INSTALLATION INSTRUCTIONS 1. 2. 2.1 2.2 2.3 2.4 GENERAL...Page 1 HANDLING...1 Receiving and Storing...1

More information

Pressure Control Valves

Pressure Control Valves Control Valves DR8- Reducing/Relieving, Direct Acting, Spool Type 4 gpm (5 l/min) 6 psi (4 bar) Description A screw-in cartridge, direct acting, spool type, pressure reducing/relieving valve with internal

More information

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : NOMINAL SIZE MATERIAL MAXIMUM SERVICE PRESSURE 200, 150, 100, 80 & 50NB Cast Iron 12 Bar (175 PSI) THREADED OPENING MOUNTING FACTORY HYDROSTATIC TEST PRESSURE

More information

Service and Parts Manual. Minimum Filtration Required:

Service and Parts Manual. Minimum Filtration Required: R GRESEN Hydraulics Model V0 Sectional Body Directional Control Valve Service and Parts Manual Maximum Operating Pressure: Minimum Filtration Required: 00 PSI ( bar) 0 Micron The information in this Service

More information

three different ways, so it is important to be aware of how flow is to be specified

three different ways, so it is important to be aware of how flow is to be specified Flow-control valves Flow-control valves include simple s to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature. The purpose of flow control

More information

Low Profile J Series Power Unit with Vane Pump

Low Profile J Series Power Unit with Vane Pump Low Profile J Series Power Unit with Vane Pump READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Accessories Series PSB. Specifications

Accessories Series PSB. Specifications Catalog HY14-252/US Technical Information General Description electrohydraulic pressure switches are high performance devices that provide an electrical signal when sensed pressure rises above or falls

More information

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration. Oil Solutions Medium Pressure Filters Filtration Global Filtration Technology www.oilsolutions.com.au Features/Applications for Medium Pressure Inline Filters GA Series Pressures to 750 PSI Flows to 100

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2661-CD/US zp2 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference Only

More information

Direct-Operated Pressure & Temperature Regulating Valves

Direct-Operated Pressure & Temperature Regulating Valves Direct-Operated & Temperature Regulating Valves Direct-Operated are used for controlling pressure or temperature in a variety of applications. Regulating Valves Page No. Cast Iron 3/8 2 Page No. O Series

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : Revolution 1999-0500 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.

More information

FLOW CONTROL VALVES A5-1 PN# / / ACC

FLOW CONTROL VALVES A5-1 PN# / / ACC FLOW CONTROL VLVES Flow Control Valves The HYDC family of flow control valves permit safe, simple and repeatable control of hydraulic fluids at operating pressures to psi. The standard slotted control

More information

Pneumatic High-Viscosity Filtration System Instruction Manual

Pneumatic High-Viscosity Filtration System Instruction Manual Pneumatic High-Viscosity Filtration System Instruction Manual P/N: 61512 05/17 1 2 Pneumatic High Viscosity Filtration Systems PN: 61512 14 April, 2009 rev A 36933 Pneumatic Hand Cart HV Filtration System

More information

Maintenance Instructions & Parts List

Maintenance Instructions & Parts List PM-PTR/LTR-C Automation Actuator Division Wadsworth, Ohio 448 October 7, 993 Rev. October 999 PTR/LTR Series Actuators Maintenance Instructions & Parts List Provide Model Number and Serial Number When

More information

Series 769 FireLock NXT Deluge Valve

Series 769 FireLock NXT Deluge Valve IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS Series 79 FireLock NXT Deluge Valve With Deluge Trim Grooved X Grooved 30.81 VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION The patent-pending

More information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information DENISON HYDRAULICS Premier Series open circuit pump controls P6 B-mod, P0 A-mod service information Publ. S-AM06-A replaces S-AM06 Internet: http://www.denisonhydraulics.com E-mail: denison@denisonhydraulics.com

More information

Trouble Shooting Manual Progressive Systems

Trouble Shooting Manual Progressive Systems 1 INTRODUCTION The information contained in this manual provides insight in how a progressive grease distribution system works and how to trouble shoot a progressive system. 2 OPERATING PRINCIPLE Any pump

More information

SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: Rated for 0- gpm (0-23 lpm). Rated for 400 psi (301bar) parallel or 3000 psi (207 bar) series. Std. port sizes (consult

More information

LINEAR MOTION CONTROL

LINEAR MOTION CONTROL LINEAR MOTION CONTROL Technical Data Sheet Rod Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

CRITICAL SUCCESS FACTORS

CRITICAL SUCCESS FACTORS Features Critical Success Factors Position Sensing Swing Clamps New Item: Hydraulic Intensifier 4:1 Power to Hold, Prices in Check 1334 East 6th Avenue Emporia, KS 66801 800-992-0236 www.vektek.com R Made

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Outlet Port Gauge Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged.

More information

KJ4000LW Operating Instructions & Parts Manual NSN

KJ4000LW Operating Instructions & Parts Manual NSN KJ4000LW Operating Instructions & Parts Manual NSN Mandus Group Ltd. KJ4000LW Operators Manual Date: 1 Oct. 2004 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page 2 KJ4000LW

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : DTL 1116 1900-0098 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information DENISON HYDRAULICS open loop pump controls series P10 A-mod, P260 B-mod service information Publ. S1-AM02-A replaces S1-AM02 01-97 CONTENTS typical characteristics-------------------------------------------------------------------------------

More information

Valves. E Valves. Multiple Hydraulic System Applications

Valves. E Valves. Multiple Hydraulic System Applications s Multiple Hydraulic System Applications Parker Check s are unidirectional flow control devices used primarily in hydraulic systems to eliminate potential damage caused by fluid back pressure. Offered

More information

Valves, Fittings, and Manifolds Catalog. We make things MOVE

Valves, Fittings, and Manifolds Catalog. We make things MOVE Valves, Fittings, and Manifolds Catalog We make things MOVE We Make Things Move A forward-thinking innovator, Bimba provides industry-leading pneumatic, hydraulic and electric motion solutions that are

More information

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO. Contents SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO. NVH081...12CNVH1...Needle Valve...10 GPM... 5500 PSI... FC5-FC6 NVH101...15CNVH1...Needle Valve...16 GPM... 5500 PSI... FC7-FC8 NV162...21CNV2...Needle

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date MEA: 248-98-E CSFM: 7770-0531-117 The patent-pending Victaulic Series 769 FireLock NXT controls the water supply entry into the deluge system piping and open sprinklers. The Series 769 is a low differential,

More information

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12 INSTALLATION, OPERATION, & #: MM-HP001 4-20-09 Rev. A Page 1 of 12 HYDRAULIC PUMP PART NUMBER HP46982ALSL & HP46982SL HYDRAULIC PUMP MM-HP001 Rev. A Page 2 of 12 Table of Contents 1.0 General Page 3 2.0

More information

Series PAVC Variable Volume, Piston Pumps

Series PAVC Variable Volume, Piston Pumps Series PVC Variable Volume, Piston Pumps Catalog 26-11-1/US 95 Introduction Series PVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *pprox. Noise Levels db() Input

More information

Series 500 Valves. Product Catalogue. Series 500 Valves. Series 500 Valves. Catalogue. Edition 10/2012

Series 500 Valves. Product Catalogue. Series 500 Valves. Series 500 Valves. Catalogue. Edition 10/2012 Series 500 Valves Product Catalogue Catalogue Areas Of Activity Waterworks Dorot s valves are especially designed to comply with all the demands of Waterworks systems such as Pressure Management, Low Flow

More information

Hayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems

Hayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems HAYWARD FILTERS Hayward FLT Series Cartridge Filters Designed for the most demanding applications these all plastic cartridge filters are used to filter fine particles from the process fluid. Models are

More information

PLK/PLKD SERIES PLK/PLKD PIN LOCATING CLAMPS

PLK/PLKD SERIES PLK/PLKD PIN LOCATING CLAMPS PLK/PLKD SERIES PLK/PLKD PIN LOCATING CLAMPS Ideal for part clamping in weld areas Disappearing Pin Weld Field Immune Switch PLK03 PLK/PLKD PIN LOCATING CLAMPS PATENT PENDING Major Benefits Completely

More information

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed

More information

[You may download this article at: https://fluidsys.org/downloads/ ]

[You may download this article at: https://fluidsys.org/downloads/ ] Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TotalPac 3 Firecyle III Wet pipe Remote controlled system (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical

More information

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) SERIES DOUBLE PILOT OPERATED CHECK VALVE... HS3 Page HD1 Page HD2 SERIES DOUBLE PILOT OPERATED CHECK VALVE GPM PSI LPM BAR CAVITY MODEL PAGE 5 3500 19

More information

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves Terms and Definitions Categories of Valves Types of Pressure Control Valves Types and Operation of Pressure Relief Valves Operation of an Unloading Valve Operation of a Sequencing Valve Operation of a

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : BTL 1114 SO CURBSIDE CARRY CAN 1910-0001 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671

More information

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work? Exercise 4-1 Flowmeters EXERCISE OBJECTIVE Learn the basics of differential pressure flowmeters via the use of a Venturi tube and learn how to safely connect (and disconnect) a differential pressure flowmeter

More information

Model 116 DPI Switch Installation and Operating Instructions

Model 116 DPI Switch Installation and Operating Instructions Mid-West Instrument Model 116 DPI Switch Installation and Operating Instructions BULLETIN NO. IM116DPIS/14A Replaces IM116DPIS/13B Industrial Control Equipment INSPECTION Before installation carefully

More information

Adjustable Differential Relay A1

Adjustable Differential Relay A1 Sales Manual Section 332 PRODUCT SPECIFICATION MODEL 84871-A1 GENERAL DESCRIPTION The 84871-A1 Adjustable Differential Diverting Relay is a two-position, snap-acting, three-way relay. Its normal function

More information

HYDROSTATIC TEST SYSTEM MANUAL

HYDROSTATIC TEST SYSTEM MANUAL PDQC HYDROSTATIC TEST SYSTEM MANUAL Technical Specification Operating Instructions Part List Revised 12-2016 Manual # PDQC- 6,000 And PDQC-10,000 1 PDQC PERFORMANCE DATA Model Number Maximum Pressure Volume

More information

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

Temperature: TYPE A (1 3) TYPE B (1/2 TYPE C (1/2 4) TYPE D (3 Sizes: Body: Bonnet: Models: Seals: s: Temperature: Specifications : ", ", 1", 2", 3", 4" Flanged ANSI EPDM Stainless Steel 304 with PCTFE Coating 30 1º F Constant Flow Valves Standard Features (Sizes

More information