Oil Test Cell Catalog No
|
|
- Harold Craig
- 6 years ago
- Views:
Transcription
1 AVTM670511a Rev A June 2005 Instruction Manual Oil Test Cell Catalog No HIGH VOLTAGE EQUIPMENT Read this entire manual before operating. Aparato de Alto Voltaje Antes de operar este producto lea este manual enteramente. M Valley Forge Corporate Center 2621 Van Buren Avenue Norristown, PA U.S.A
2
3 Oil Test Cell Instruction Manual
4 Copyright by Megger. All rights reserved. The information presented in this manual is believed to be adequate for the intended use of the product. If the product or its individual instruments are used for purposes other than those specified herein, confirmation of their validity and suitability must be obtained from Megger. Refer to the warranty information below. Specifications are subject to change without notice. WARRANTY Products supplied by Megger are warranted against defects in material and workmanship for a period of one year following shipment. Our liability is specifically limited to replacing or repairing, at our option, defective equipment. Equipment returned to the factory for repair must be shipped prepaid and insured. Contact your MEGGER representative for instructions and a return authorization (RA) number. Please indicate all pertinent information, including problem symptoms. Also specify the serial number and the catalog number of the unit. This warranty does not include batteries, lamps or other expendable items, where the original manufacturer s warranty shall apply. We make no other warranty. The warranty is void in the event of abuse (failure to follow recommended operating procedures) or failure by the customer to perform specific maintenance as indicated in this manual. M Valley Forge Corporate Center 2621 Van Buren Ave Norristown, PA (Telephone) (Fax)
5 Table of Contents 1 Introduction... 1 Receiving Instructions... 1 General Information Safety Specifications Operation... 7 Cleaning the Test Cell... 7 Filling the Test Cell... 7 Testing a Liquid... 8 Checking Megger Capacitance & Dissipation Factor Test Sets Replaceable Parts List List of Figures Figure 1: Oil Test Cell and Accessories... 2 Figure 2: Oil Test Cell Shown Disassembled for Cleaning... 8 Figure 3: Test Setup to Measure the Dissipation Factor of a Liquid Figure 4: Test Setup as a Capacitance and Dissipation Factor Standard i
6 M ii
7 1 Introduction Receiving Instructions Check the equipment received against the packing list to ensure that all materials are present. Notify Megger of any shortage. Telephone Examine the equipment for damage received in transit. If damage is discovered, file a claim with the carrier at once and notify Megger, giving a detailed description of the damage. This test cell has been thoroughly tested and inspected to meet rigid specifications before being shipped. It is ready for use when set up as indicated in this manual. General Information The Oil Test Cell is intended for use with Megger Capacitance and Dissipation Factor Test Sets, including the DELTA-2000 Automated Insulation Power Factor Test Set, to measure the permittivity (dielectric constant) and dissipation factor (DF)/power factor (PF) of insulating liquids in the field. Measurements may be made ungrounded (UST) or grounded (GST) and grounded with guard connected (GSTg). The Oil Test Cell is a three-terminal type, using a guard ring to eliminate strays and leakage. The following accessories are supplied with the test cell: calibration standard resistor, mercury-in-glass thermometer, two jumper leads, and carrying case. See Figure 1. Applicable test specifications are: IEC Publication Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths ASTM D924-82b (reapproved 1990) - Standard Test Method for AC Loss Characteristics and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids ASTM D Standard Test Method for Specific Resistance (Resistivity) of Electrical Insulating Liquids 1
8 M Carrying Case Oil Test Cell Jumper Leads Calibration Standard Resistor Mercury in-glass Thermometer Figure 1: Oil Test Cell and Accessories 2
9 2 Safety The Oil Test Cell contains no source of power and does not present a shock hazard in itself. However, the test cell is normally energized from a Capacitance and Dissipation Factor Test Set that has the capability to produce a 10 kv, 50/60 Hz source of electrical energy. All persons making or assisting in tests must use all practical safety precautions to prevent contact with energized parts of the test equipment and related circuits. Persons actually engaged in the test must stand clear of all parts of the complete high-voltage circuit, including all connections, unless the test set is de-energized and all parts of the test circuit are grounded. Persons not directly involved with the work must be kept away from test activities by suitable barriers, barricades, or warnings. An interlock circuit is provided with the Megger Capacitance and Dissipation Test Set to enable the operator to enclose all parts of the complete high-voltage circuit within a secure area. The interlock circuit should be used to shut off input power automatically upon unauthorized entry into the highvoltage area. Megger has made formal safety reviews of the initial design and any subsequent changes. This procedure is followed for all new Megger products and covers areas in addition to those included in applicable ANSI standards. Regardless of these efforts, it is not possible to eliminate all hazards from electrical test equipment. For this reason, every effort has been make to point out in this instruction manual the proper procedures and precautions to be followed by the user in operating this equipment and to mark the equipment itself with precautionary warnings where appropriate. It is no possible however to foresee every hazard which may occur in the various applications of this equipment. It is therefore essential that the user, in addition to following the safety rules in this manual, also carefully consider all safety aspects of the test before proceeding. Users of high-voltage equipment should note that high-voltage discharges and other sources of strong electric or magnetic fields may interfere with the proper operation of heart pacemakers. Personnel having heart pacemakers should obtain expert advice on possible risks before using this equipment or being close to equipment while it is in operation. If the test equipment is operated properly and all grounds correctly made, test personnel need not wear rubber gloves. As a routine safety procedure, however, 3
10 M some users require that rubber gloves be worn, not only when making connections to high-voltage terminals, but also when manipulating the controls. Megger considers this an excellent safety practice. Safety is the responsibility of the user. The purpose of the Oil Test Cell is limited to use as described in this manual. Do not use the test cell or its accessories with any type equipment other than specifically described. Connect the GROUND terminal of the test instrument to a low-impedance earth ground. Stay clear of all exposed connections and conductors while the test is in progress. Do not connect the Oil Test Cell to energized equipment. Do not perform tests in an explosive atmosphere. Misuse of high-voltage equipment can be extremely dangerous. A qualified operator should be in attendance at all times while a test is in operation. Observe all safety warnings marked on test equipment and accessories. Do not perform tests in direct rain or snow. Refer to IEEE IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing for more information. The following warning and caution notices are used throughout this manual where applicable and should be strictly observed. F WARNING Warning, as used in this manual, is defined as a condition or practice which could result in personal injury or loss of life. G CAUTION Caution, as used in this manual, is defined as a condition or practice which could result in damage to or destruction of the equipment or apparatus under test. 4
11 3 Specifications Cell Type: Capacitance: Test Voltage: Guard: Gap Spacing: Average Voltage Stress: Dissipation Factor (DF): Three terminal, full guarded. Approximately 55 pf when filled with air. 10 kv rms maximum, filled with liquid. 5 kv rms maximum, empty. Low voltage type, 2 kv rms maximum voltage in. (0.90 cm) nominal. 10 kv test voltage: 28.6 v/mil (1125 v/mm) 2.5 kv test voltage: 7.15 v/mil (280 v/mm) Power Factor (PF): Less than 0.02% DF when filled with air. Using the calibration standard resistor with the 55 pf cell, the 0.5 MΩ resistor will measure in the range of 0.95 to 1.05% DF at 60 Hz. Using the 5 MΩ resistor will measure in the range of 9.5 to 10.5% DF at 60 Hz. For 50 Hz test voltage, the DF will be 5/6 of the values given. Fluid Sample: Dimensions: Weight: 1-1/4 pint (0.6 L) fills the cell. 11 x 9 x 7-1/2 in. (W x D x H) (28 x 23 x 19 cm) Test cell and accessories in carrying case 6 lb (2.7 kg) test cell and accessories in carrying case 5
12 M Accessories: Mercury-in glass thermometer, -10 to 110 C Calibration standard resistor (nominally 0.5 MΩ and 5 MΩ) Two jumper leads, 2 ft (0.61 m), with spring clips on each end. Environmental: Operating temperature range: 35 to 175 F (2 to 80 C) Storage temperature range: -58 to 175 F (-50 to 80 C) Humidity: 0 to 90% noncondensing (operating) 0 to 95% noncondensing (storage) 6
13 4 Operation Cleaning the Test Cell Before using the test cell, it is important that it first be dismantled and thoroughly cleaned and dried. The loss characteristics of an insulating liquid may be significantly affected by minute amounts of contamination or moisture. If, in the field, it is impractical to wash all parts with a solvent, then soap and water and oven dry them; wash all component parts with a technical grade of suitable solvent following all the manufacturer s recommended safety precautions, then wipe dry with clean dry rags. Clean the test cell each time a different liquid sample is tested. When handling the cell parts after cleaning, do not touch the inner surface of the outer shell, the surfaces of the inner electrode and the insulating members. Take care to avoid any nicks or scratches in the insulating or electrode surfaces. To dismantle the inner electrode and top assembly for cleaning, unscrew the knurled nut from the top high-voltage electrode (pigtail) and separate the inner electrode from the shell cover. Then, unscrew the top part of the guard ring and separate the top-cover parts. Figure 2 shows the cell disassembled for cleaning. Filling the Test Cell Disassemble and clean the test cell before filling. Refer to the preceding section, Cleaning the Test Cell. When handling the cell, take care to avoid any nicks or scratches in the insulating or electrode surfaces. Also, do not touch the inner surface of the outer shell, the surfaces of the inner electrode and the insulating members. Fill the cell by lifting the inner electrode and cover assembly from the outer shell, and filling the shell with the liquid sample to a height of 2 ½ in.; use the thermometer as a depth marker or dipstick. Be sure that the thermometer is clean so that the liquid sample will not be contaminated by surface moisture or other material. After filling the outer shell to the prescribed level, insert the inner electrode assembly slowly, and turn it back and forth several times to release any gas or air 7
14 M bubbles that may be clinging to polished surfaces. Lightly tapping the outer shell will also help to remove bubbles. Figure 2: Oil Test Cell Shown Disassembled for Cleaning Testing a Liquid NOTE: The test cell should always be dry and a t a temperature above the dew point before filling. Follow all safety precautions. Refer to Section 2, Safety of this manual and the appropriate manual for the Capacitance and Dissipation Factor Test Set used. Figure 3 shows the setup arrangement. The test procedure is as follows, when using a Megger Catalog No , , , , , or test set. 1. Place the test cell on a sturdy level surface. 2. Position the test cell at least 6 ft (1.82 m) away from the test set. 3. Use suitable protective barriers, barricades, and interlocks for the setup. 4. Clean the test cell as previously described. 5. Fill the test cell as previously described. 6. Connect the Capacitance and Dissipation Factor Test Set to the test cell as follows. If convenient, the two jumper leads may be used. 8
15 Operation F WARNING Maintain a clearance of approximately 1 in. (2.5 cm) between HV electrode and guard ring so that a flashover will not occur between these parts. Rigidly secure all test leads before making connections to te st cell to prevent capsizing of test cell while making a setup or during a measurement. a. Connect the black HV lead of the test set to the HV electrode (pigtail terminal) of the test cell. b. Connect the red LV lead of the test set to the pin terminal on the outside container of the test cell. c. Connect the blue LV lead of the test set to the guard ring of the test cell. 7. The setup is now complete and ready for testing. 8. Set the TEST MODE selector switch of the test set to the UST3 position that measures to the red lead and grounds to the blue lead. If using the DELTA-2000 (Cat. No ), choose UST-MEASURE RED, GROUND BLUE LOW VOLTAGE LEAD CONFIGURATION. A test could also be performed in the grounded mode using the GST position that guards the blue lead and grounds the red lead; however, this test would be more susceptible to stray and interference coupling. 9. Energize the test set and gradually increase the voltage to the desired test level. Keep in mind that the maximum voltage that can be applied to the test cell is: 10 kv rms maximum, filled with liquid 5 kv rms maximum, empty G CAUTION A flashover may occur above the liquid level if there is an insufficient amount of liquid in the test cell. 10. Measure the capacitance and dissipation factor of the liquid. 11. De-energize the test set and apply a safety ground stick to the exposed highvoltage terminal to discharge the specimen and test set. 12. Then measure the temperature of the liquid sample while still in the test cell. Insert the glass thermometer in the hole in the top cover of the cell to make this measurement. The dissipation factor should be corrected to 20 C using the appropriate multipliers for the type liquid tested. 9
16 M When samples of insulating liquids are tested, the specimen capacitance is used when determining the permittivity (dielectric constant) of the insulating liquids. The ratio of the test cell capacitance measured when filled with a liquid divided by the test cell capacitance measured when empty is the value of the permittivity of the liquid. Checking Megger Capacitance & Dissipation Factor Test Sets The Oil Test Cell and calibration standard resistor may also be used to perform a very rough check of the calibration of Megger Capacitance and Dissipation Factor Test Sets, including the DELTA-2000 Automated Insulation Power Factor Test Set, at a voltage of 5 kv or less. For a high accuracy check, the Megger Catalog No Calibration Standard should be used. The setup and test procedure is essentially identical to that used for testing a liquid. First, with the test cell clean and no liquid used, set up as shown in Figure 3. Do not use the mercury thermometer. Figure 3: Test Setup to Measure the Dissipation Factor of a Liquid F WARNING Maintain a clearance of approximately 1 in. (2.5 cm) between HV electrode and guard ring so that a flashover will not occur between these parts. Rigidly secure all test leads before making connections to test cell to prevent capsizing of test cell while making a setup or during a measurement. Set the TEST MODE selector switch of the test set to the UST3 position that measures to the red lead and grounds to the blue lead. If using the DELTA
17 Operation (Cat. No ), choose UST - MEASURE RED, GROUND BLUE LOW VOLTAGE LEAD CONFIGURATION. Then measure capacitance and dissipation factor in the usual manner using a test voltage of 5 kv or less. The test cell capacitance value in picofarads is listed on the nameplate of the test cell (nominally 55 pf). The test cell dissipation factor is nominally 0%DF. A resistance unit, supplied with the test cell, provides two standard values of resistance (R), nominally 0.5 MΩ and 5 MΩ. Suitable-metal rods are provided for mounting the resistance unit on the center HV electrode of the test cell, and for connecting the black HV lead of the test set to the resistance unit. Figure 4 shows the test setup to use the resistance standard and Oil Test Cell as a capacitance and dissipation factor standard. To mount the resistance unit on the test cell, connect one of the two-pin receptacles at one end of the resistance unit to HV electrode (pigtail) terminal of the test cell. Connect the HV lead of the test set to the single pigtail pin on the upper end of the resistance unit. The guard lead (blue LV lead) and UST lead (red LV lead) connections are made the same as when using the cell to test liquids. After measuring the capacitance and dissipation factor, shift the connection to the other pin receptacle of the resistance unit and again measure the capacitance and dissipation factor. With a test cell capacitance of nominally 55 pf, the 0.5-MΩ resistor should measure in the range of 0.95 to 1.05 percent dissipation factor at 60 Hz. The 5- MΩ resistor should measure in the range of 9.5 to 10.5 percent dissipation factor at 60 Hz. NOTE: For 50-Hz test voltage, the dissipation factors will be 5/6 of the values given above. 11
18 M Figure 4: Test Setup as a Capacitance and Dissipation Factor Standard 12
19 5 Replaceable Parts List Description Part No. Test cell 9962 Calibration standard resistor 9961 Mercury-in-glass thermometer Jumper leads (two) 6046 Carrying case 9959 Center pigtail electrode of cell
20 M M 14
Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and
AVTM220003 Rev. B January 2003 Instruction Manual AVTM220003 for DC µa Strip Chart Recorder Catalog Nos. 220003 and 220003-47 PO Box 9007 Valley Forge, PA 19485-1007 U.S.A. 610-676-8500 Shipping Address:
More informationDELTA4000 Accessories
DELTA4000 Accessories TESTING LARGE SPECIMENS Resonating Inductor The resonating inductor expands the capacitance range of the DELTA automated insulation power factor test sets. The resonating inductor
More information-30kV DC Insulation Tester MIT30 Catalog No. MIT30
AVTMMIT30-EN Rev E02 June 2009 Instruction Manual -30kV DC Insulation Tester MIT30 Catalog No. MIT30 High Voltage Equipment THIS EQUIPMENT PRODUCES INSTANTANEOUSLY LETHAL VOLTAGE Please read carefully
More information15 kv DC Dielectric Test Set Catalog No Series
AVTM22-15Ja Rev B December 2008 15 kv DC Dielectric Test Set Catalog No. 220015 Series HIGH-VOLTAGE EQUIPMENT PLEASE READ CAREFULLY BEFORE OPERATING Safety is the responsibility of the user APARATO DE
More informationDELTA4000. Accessories
DELTA4000 Accessories WWW.MEGGER.COM TESTING LARGE SPECIMENS Resonating Inductor The resonating inductor expands the capacitance range of the DELTA automated insulation power factor test sets. The resonating
More informationPHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S
VOLTMETERS PHASERS a n d A C C E S S O R I E S Operating and Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E WA U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. PHONE 847.473.4980
More informationKV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge
More informationSecoVac * Ground & Test Device
GE Industrial Solutions DEH-50007 Installation, Operation and Maintenance Manual SecoVac * Ground & Test Device For 5kV-15kV IEEE Metal-clad Switchgear Table of Contents 1. Introduction...6 Safety Precautions...6
More informationGeneral Installation Instructions for Valves and Gates
General Installation Instructions for Valves and Gates Thank you for your purchase of a Lorenz valve. We appreciate your business! Please read this installation manual and follow recommended safety precautions.
More informationMIT515, MIT525, MIT1025, MIT1525
MIT515, MIT525, MIT1025, MIT1525 Measures up to 30 TΩ Safety rated up to CAT IV 1000 V to 3000 m Unique dual-case design - additional user protection Operates from battery or a.c. mains supply Rapid charge
More informationINSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.
INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material
More informationModel 2053 Conductivity Meter Instruction Manual
Model 2053 Conductivity Meter Instruction Manual Printed in U.S.A. 09/2006 Ship Date: Serial Number: Calibrated By: Table of Contents Page 1. Introduction.. 1 2. Shipping Checklist.. 1 3. Specifications...
More informationDigital/Analog Megohmmeter Model 1026 USER MANUAL
Digital/Analog Megohmmeter Model 1026 USER MANUAL Limited Warranty The Megohmmeter Model 1026, is warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture.
More informationBM kv Digital Insulation Tester USER MANUAL
M BM5200 5 kv Digital Insulation Tester USER MANUAL CONTENTS Safety warnings...3 Symbols used on instrument...4 Cleaning...4 General description...5 Insulation resistance test modes...5 Automatic discharge...5
More informationNEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions
More informationPD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL
PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL Index 1. Safety precaution... 2. Specifications... 3. Operation... 4. Warning... 5. Cleaning... 6. Rated environmental conditions... 7. Observe the international
More informationKeystone Butterfly valves ParaSeal Installation and maintenance instructions
Before installation these instructions must be fully read and understood Please read these instructions carefully Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationTechnical Information Manual
Technical Information Manual Revision n. 4 18 June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04 CAEN will repair or replace any product within the guarantee period if
More informationUser's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model
User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects
More informationUser Guide. Model Insulation Tester / Megohmmeter. Introduction
User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity
More informationOPERATING INSTRUCTION
11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail
More information1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide
1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationHTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080
Befour, Inc. 102 Progress Drive Saukville, WI 53080 Phone: 262-284-5150 Toll Free: 1-800-367-7109 Fax: 262-284-5966 Email: mail@befour.com www.befour.com 2014 Befour, Inc. Rev.1 HTR-202 Portable Digital
More information801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS
280-600 Send Warranty Product Repairs to: 1025 E. Thompson Ave., Hoopeston, IL 60942-0280. Call Customer Service if you have questions: 1-800-621-5485 A. IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS
More informationThese installation and maintenance instructions must be read in full and completely understood before the installation!
These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationPRODUCT SERVICE MANUAL
PRODUCT SERVICE MANUAL FOR AM322ICX-325AE, 350AN and 400A PUMPS WARNING This Special Instruction Manual and General Instructions Manual, SRM00046, should be read thoroughly prior to pump installation,
More informationPhase Sequence Tester
User's Guide Phase Sequence Tester Model 8000 Introduction Congratulations on your purchase of the Extech Model 0800 Phase Sequence Tester. This handheld instrument detects the phase sequence of three-phase
More informationModel 616 Rotating Disk Electrode Instruction Manual
Model 616 Rotating Disk Electrode Instruction Manual 219303 C / 1202 Printed in USA Advanced Measurement Technology, Inc. a/k/a Princeton Applied Research, a subsidiary of AMETEK, Inc. WARRANTY Princeton
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationRENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev
Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.
More informationModel HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationMY /2-DIGIT DIGITAL MULTIMETER Users Manual
MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of
More informationDawson DDM190D. Digital Multimeter User s Manual
Dawson DDM190D Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION...
More informationKD1E Range Potential Indicators
KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Limited Warranty & Limitation
More informationOPERATIONS MANUAL LEVER CHAIN HOIST
OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions
More informationINSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03
INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment
More informationOPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0
OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0 TABLE OF CONTENTS Section Number DANGER PRODUCT INFORMATION 1 -SAFETY AND CAUTION NOTES -DESCRIPTION
More information55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET
FEATURES SPECIFICATIONS Power Consumption 10W Output Voltage 18~59Vdc MAX Input Current 500 ma Emergency Time 90 Minutes Battery Specification 14.4V/2000mAH Dimension (Inches) 12.6 (L) x 1.8 (W) x 1.3
More informationAXD 530 MicroManometer
OWNER S MANUAL AXD 530 MicroManometer A TSI Company Table of Contents Features 2 Using the AXD530 Safely 3 Getting Started 4 Installing Batteries 4 Preparing the Instrument 4 Attaching the Optional Pitot-Static
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationELB ELB
ELB-35-600 ELB-35-610 600A T-Body Elbow Connectors for Copper Tape (CT), Jacketed Concentric Neutral (JCN), and Concentric Neutral (CN) cables up to 35kV class Safety Instructions When installing electrical
More informationINSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT
CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings
More informationOperator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:
Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All
More informationINSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)
POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 480 Volts, 60Hz April 15, 2010: updated capacitor UL File number) Page 1 of 14 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Advantage
More informationOperating Instructions - Electric Pow'r-Riser Models
ADivisionOf Templeton, Kenly& Co., Inc. Operating Instructions - Electric Pow'r-Riser Models Table of Contents 1.0 Recieving Instructions 2.0 Safety 3.0 Specifications 4.0 Initial Installation Before Operating
More informationVAN DE GRAAFF GENERATORS - 400kV
VAN DE GRAAFF GENERATORS - 400kV EM4133-101 220/240 V.AC. with earth. 50/60 Hz. 300mm diameter ball generates about 400kV DESCRIPTION: The I EC 300mm diameter Van De Graaff Generator is a modern, compact
More informationInstruction Manual. Model 307A Analog Insulation & Continuity Meter
Instruction Manual Model 307A Analog Insulation & Continuity Meter Index Page Safety Precautions... 1 Safety Notes... 2 Features... 2-3 Connections... 3 Specifications...... 4 Why Test is necessary...
More informationCALIBRATION TEST FIXTURES
CALIBRATION TEST FIXTURES Model 809B (Surface) Model 819 (Volume) Instruction Manual 7/08 1.0 INTRODUCTION The Model 809B Surface Resistance Calibration Test Fixture and the Model 819 Volume Resistance
More informationCTFRP Series Power Supplies
CTFRP Series Power Supplies Ferroresonant Non-Standby Power Supplies User Manual Myers Power Products 6/2013 CTFRP Series Manual Chapter 1 General Information The Myers CTFRP Series Power Supply provides
More informationi400s Calibration Information Introduction
i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided
More information25 kv Apparatus Bushings
Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation
More informationOPERATING INSTRUCTION
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 8/05 Form #270 OPERATING INSTRUCTION MODEL 3005 DIGITAL INSULATION-CONTINUITY TESTER
More informationINSTRUCTION MANUAL DM5B Fax: (503)
INSTRUCTION MANUAL DM5B 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The DM5B digital multimeter is a pocket sized, hand held, battery operated, voltage, current
More informationSLA Battery Capacity Analyzer
Model: 600B SLA Battery Capacity Analyzer USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation,
More information25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic
More informationInstallation, Operation, and Maintenance
S&C Regulator Bypass Switches Outdoor Distribution (14.4 kv through 25 kv) Type XL (Sequenced) and Type NL (Non-sequenced) Installation, Operation, and Maintenance Table of Contents Section Page Section
More informationThis manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding
Installation, Operating, Maintenance & Safety Instruction for M PUMPS CM MAG-M SERIES Centrifugal light Mag-Drive pumps (CM MAG-M06/1/2/3/4) This manual presents installation, servicing, troubleshooting,
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More information5.2 PRE-OPERATION PROCEDURE WARRANTY
4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any
More information35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other
More informationFull View Flow Indicator
Full View Flow Indicator Threaded and Flanged Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com
More informationUsers Manual. Phase Rotation Indicator
9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are
More informationButterfly valves Figure 56 Installation & Maintenance Instructions
KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently
More informationDynaCon Instruction Manual
DynaCon Instruction Manual Table of Contents Technical Specification & Warranty.... 3 Construction, Benefits & Safe Operating Procedures... 4 Noise Levels... 5 Installation, Operation & Maintenance...
More information0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)
Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and
More informationBroadBand PowerShield. 20 AHr Battery. User Manual
BroadBand PowerShield 20 AHr Battery User Manual 990-1316A 10/2004 Chapter 1 General Information The PowerShield provides a power source for broadband telephony applications. Important Safety Instructions
More information801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322
277-999 ELECTRIC CORP. 801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS 800-621-5485 Ext. 322 Send Warranty Product Repairs to: 605 South Vermilion, Suite C, Brownsville, TX 78521-6851 Call Customer
More informationPneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )
Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R434001268 (Formerly P -193419-00003) Service Information INSTALLATION Before installing this cylinder, all air lines in the system should be blown clean
More informationQPET, QPETXU Battery Chargers
C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QPET, QPETXU Battery Chargers INTRODUCTION: The QPET line of chargers are designed for general purpose deep cycle batteries. They are an electronically
More informationBio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications
Bio-Pump Plus Product # ZBP-200 Operating Instructions Description The Bio-Pump Plus is an advanced portable, battery powered air sampling pump designed for the exclusive use with Air-O-Cell,Via-Cell,
More informationHT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option
HT-10000 Dielectric Withstand Tester 0-10000 Volts AC Output 25mA Leakage Option Instruction Manual COMPLIANCE WESTUSA Dear Customer: Congratulations! Compliance West USA is proud to present you with your
More informationHI-POT/CONTINUITY TESTER Model PLEP01
HI-POT/CONTINUITY TESTER Model PLEP01 Instruction Manual MITCHELL INSTRUMENT CO. Dear Customer: Congratulations! Mitchell Instrument Co. is please to present you with your Hipot/Continuity Tester. This
More informationVacuum Circuit Breaker (Vehicle)
Vacuum Circuit Breaker (Vehicle) Type 5 HVU-250 4.76kV Instructions Installation Operation Maintenance SGIM-9998A Hazardous voltages and high-speed moving parts. Will cause death, serious injury or equipment
More informationINSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:
Other products from Martindale: 18th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s Kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital
More informationSpecification Approval Sheet
Specification Approval Sheet Name: Lithium-Ion Rechargeable Battery Model: 30001-1 SPEC: 14500, 3.7V, 800mAh Approved By Checkup Make Signature Date Customer Confirmation Company Name: Stamp:, U.S.A. www.tenergybattery.com
More information35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other
More informationDUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (USED FOR POWERING ENVIRONMENTAL ENCLOSURE MODELS MODELS 854030, 8535 AND 8537) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION C JUNE 2017
More informationWELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04
WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...
More informationDigital/Analog Megohmmeter Model 1026
Digital/Analog Megohmmeter Model 1026 USER MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents Warning...3
More informationVacuum Circuit Breakers (Vehicle)
Vacuum Circuit Breakers (Vehicle) Type 5 HVR 4.16kV Instructions Installation Operation Maintenance SGIM-9948D Hazardous voltages and high-speed moving parts. Will cause death, serious injury or equipment
More informationmaterials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:
WARRANTY The Drucker Company warranties that this centrifuge is free from defects in materials and workmanship for 2 years. Should the centrifuge require warranty or out-of-warranty service please contact:
More informationComponent Test Fixture
PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT 1865-52 Component Test Fixture User and Service Manual 1865-52 im/march 2010 Copyright 2010 IET Labs, Inc. IET LABS, INC. 534 Main Street, Westbury, NY 11590
More informationRefinery Supply Company, Inc.
Refinery Supply Company, Inc. OPERATING INSTRUCTIONS Super Pressure Dead Weight Tester Catalog No. 35260 Serving the Oil & Gas Industry since 1923 9133-A East 46th Street Tulsa, Oklahoma 74145-4823 Voice
More informationRadiation Safety Requirements for the Use of Non-Medical X- Ray.
290-5-22-.06 Radiation Safety Requirements for the Use of Non-Medical X- Ray. (1) Purpose. This section establishes the requirements for the non-healing arts use of x- rays. (2) Scope. This section applies
More informationMULTIVOLTAGE PORTABLE BATTERY CHARGER MVM
_ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take
More informationTest Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers
DEH41480 Test Cabinet (Inspection Box) for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers Instructions 1 Table of Contents Section 1. Introduction
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More informationKEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be
More informationMODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE
MODEL A96 SERIES 130Vdc Switchmode Utility Rectifier / Battery Charger Used with LaMarche Power Cage CPN112138 ECN/DATE ISSUE DATE: ECN 17010-12/05 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847)
More informationMetrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.
Metrohm Martindale Electric Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK T: 01923 441717 F: 01923 446900 Email: sales@martindale-electric.co.uk web: www.martindale-electric.co.uk
More informationRosemount 402 and 402VP
Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More information8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5
\ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole
More informationInstruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake
ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -
More informationPositive Displacement Pump
www.conairgroup.com U S E R G U I D E UGC028-1105 Positive Displacement Pump Models PD 3. 5, 7.5, 10, 15 and 25 Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l
More informationGuardian Battery Charger Series. Installation and Operations Manual Section 75
Guardian Battery Charger Series Installation and Operations Manual 00-02-0615 02-29-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to
More informationIntroduction CAUTION. S&C Power Operated Metal-Enclosed Switchgear Outdoor Distribution (4.16 kv, through 34.5 kv)
S&C Power Operated Metal-Enclosed Switchgear Outdoor Distribution (4.16 kv, through 34.5 kv) Inspection Recommendations for Switchgear with Type AT-3 Source- Transfer Controls Table of Contents Section
More informationUser's Manual. Earth Ground Resistance Tester. Model Introduction
User's Manual Earth Ground Resistance Tester Model 382152 Introduction Congratulations on your purchase of the Extech Earth Ground Resistance Tester. This device can measure resistance (in 3 ranges) and
More informationPneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P
Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P -322908-00000 Replaces Part No. P-191067-00000 Service Information WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More information